INTRODUCTION :
Commissioning is a process of integrating site i.e downloading site codes to BTS, calibration of TRX unit, measurement of VSWR, measurement of reverse power, documentation of the site etc.
MMI-RAM 1015 -> chg_l Enter password for security level you wish to access: (press ) Current security level is 2
c.
For changing security level from one to third. Enter the following command;
MMI-ROM 1015 -> chg_l Enter password for security level you wish to access:3stooges Enter password for security level you wish to access:4beatles Current security level is 3
Note site number is different for different sites. state (site number) dri (dri id) This command is used to check status of all/particular dri. This command gives status of dri ( i.e how many dri are busy, dri are busy on which rtf, how many dri are equipped, time & date of last action of dri). 2. Syntax & Massage after execution of this command is shown below:
MMI-RAM 1015 -> state 30 dri * * DEVICE STATUS INFORMATION FOR LOCATION 30: OPER STATES: D:Disabled E:Enabled B:Busy ADMIN STATES: L:Locked U:Unlocked E:Equipped
S:Shutdown Related Function --------None RTF 0 0 0 None None RTF 1 0 0 None None None RTF 2 0 0 None None None
Device ------------DRI 0 0 0 DRI 0 1 0 DRI 0 2 0 DRI 0 3 0 DRI 1 0 0 DRI 1 1 0 DRI 1 2 0 DRI 1 3 0 DRI 2 0 0 DRI 2 1 0 DRI 2 2 0 DRI 2 3 0
State ----D-L B-U E-U E-U B-U E-U E-U E-U B-U E-U E-U E-U
Reason ------------------------NO REASON NO REASON NO REASON NO REASON NO REASON NO REASON NO REASON NO REASON NO REASON NO REASON NO REASON NO REASON
Last Transition dd/mm hh:mm:ss --------------08/09 16:49:22 08/09 16:49:56 08/09 16:35:08 08/09 16:35:14 08/09 16:35:08 08/09 16:35:14 08/09 16:34:46 08/09 16:34:46 08/09 16:35:02 08/09 16:35:02 08/09 16:35:08 08/09 16:35:08
In the above massage, we see that there are twelve DRI are equipped. Four dris in all sector. DRI with id starting from 0 is in first sector, similarly DRI with id
In the above massage, all information is same as DRI command. 4. disp_cal_data (site number) dri (dri id) This command is used to display calibration data of the particular DRI.
5.
disp_cell_s (site number) This command is used to check how many calls are going on in all sectors.
Numbers of inuse traffic channels shows, numbers of calls going on in the all sectors. First group shows first sectors, second group shows second sectors, and third group shows third sectors. 6. disp_rtf_ch (site number) (rtf id) This command is used to check numbers of time slots are active & call drop.
7. DRI.
disp_eq (site number) dri (dri id) This command is used to check equipage of the DRI. That give complete details of the
8.
disp_int This command is used to check current time interval of the site.
9.
l (site number) dri (dri id) This command is used to lock the particular DRI.
10.
unl (site number) dri (dri id) This command is used to unlock the particular DRI.
11.
12. disp_stats (time interval) path_balance cell_number (MCC id) (MNC id) (LAC id) (Cell id)
This command is used to check path balance of the sites. This command gives balance value between TX path and RX path. The mean value of path balance should be in the range of 108 to 112 for 900 MHz band. Path balance value 105 can be acceptable if it is 1800 MHz band. Path balance command is separately entered and executed for each sectors.
Syntax & Massage after execution of this command is shown below:
Command for sector first. MMI-RAM 1015 -> disp_stats 2 path_balance cell_number 4 0 4 1 1 109 18521 SITE : 30 RTF ID : 0 0 CELL #: LAC=006Dh CI=4859h
SITE : 30 CELL #: LAC=006Dh CI=4859h RTF ID : 0 0 MEAS_TYPE : PATH_BALANCE Distribution Mean : 111 Distribution Max. : 135 Distribution Min. : 81 Bin : 0 0 0 2 3137 5957 3 0 0 0
SITE : 30 RTF ID : 0 1
SITE : 30 CELL #: LAC=006Dh CI=4859h RTF ID : 0 1 MEAS_TYPE : PATH_BALANCE Distribution Mean : 110 Distribution Max. : 129 Distribution Min. : 92 Bin : 0 0 0 0 4065 4442 0 0 0 0 SITE : 30 RTF ID : 0 2 CELL #: LAC=006Dh CI=4859h
SITE : 30 CELL #: LAC=006Dh CI=4859h RTF ID : 0 2 MEAS_TYPE : PATH_BALANCE Distribution Mean : 109 Distribution Max. : 135 Distribution Min. : 92 Bin : 0 0 0 0 5065 4244 16 0 0 0 SITE : 30 RTF ID : 0 3 CELL #: LAC=006Dh CI=4859h
SITE : 30 CELL #: LAC=006Dh CI=4859h RTF ID : 0 3 MEAS_TYPE : PATH_BALANCE Distribution Mean : 110 Distribution Max. : 133 Distribution Min. : 81 Bin : 0 0 0 26 6859 9906 1 0 0 0 Command for second sector. MMI-RAM 1015 -> disp_stats 2 path_balance cell_number 4 0 4 1 1 109 18522 SITE : 30 RTF ID : 1 0 CELL #: LAC=006Dh CI=485Ah
SITE : 30 CELL #: LAC=006Dh CI=485Ah RTF ID : 1 0 MEAS_TYPE : PATH_BALANCE Distribution Mean : 111
SITE : 30 CELL #: LAC=006Dh CI=485Ah RTF ID : 1 1 MEAS_TYPE : PATH_BALANCE Distribution Mean : 111 Distribution Max. : 127 Distribution Min. : 95 Bin : 0 0 0 0 553 1065 0 0 0 0 SITE : 30 RTF ID : 1 2 CELL #: LAC=006Dh CI=485Ah
SITE : 30 CELL #: LAC=006Dh CI=485Ah RTF ID : 1 2 MEAS_TYPE : PATH_BALANCE Distribution Mean : 112 Distribution Max. : 125 Distribution Min. : 96 Bin : 0 0 0 0 617 1904 0 0 0 0 SITE : 30 RTF ID : 1 3 CELL #: LAC=006Dh CI=485Ah
SITE : 30 CELL #: LAC=006Dh CI=485Ah RTF ID : 1 3 MEAS_TYPE : PATH_BALANCE Distribution Mean : 111 Distribution Max. : 141 Distribution Min. : 82 Bin : 0 0 0 69 7350 12118 63 0 0 0 Command for third sector. MMI-RAM 1015 -> disp_stats 2 path_balance cell_number 4 0 4 1 1 109 18523 SITE : 30 RTF ID : 2 0 SITE : 30 CELL #: LAC=006Dh CI=485Bh
10
SITE : 30 CELL #: LAC=006Dh CI=485Bh RTF ID : 2 1 MEAS_TYPE : PATH_BALANCE Distribution Mean : 112 Distribution Max. : 138 Distribution Min. : 90 Bin : 0 0 0 0 2617 6593 17 0 0 0 SITE : 30 RTF ID : 2 2 CELL #: LAC=006Dh CI=485Bh
SITE : 30 CELL #: LAC=006Dh CI=485Bh RTF ID : 2 2 MEAS_TYPE : PATH_BALANCE Distribution Mean : 113 Distribution Max. : 137 Distribution Min. : 93 Bin : 0 0 0 0 159 940 2 0 0 0
13.
disp_act_a (site number) This command is used to check current active alarm of the site. It can be either external alarm or internal alarm. Syntax & Massage after execution of this command is shown below:
MMI-RAM 1015 -> disp_act_a 30 ACTIVE ALARM INFORMATION FOR LOCATION 30: Device Alarm (Subtype) Code -------------------- ---EAS 1 0 0 19 IAS 0 0 0 Clear Type Tag(hex) Date/Time ---- -------- ---------FMIC Untagged 09-08-2004 16:32:58 41 FMIC Untagged 09-08-2004
11
14.
alarm_mode (site number) on This command is used to enabling alarm mode of the site. After enabling alarm mode each and every alarm raised is appear on the screen. These alarms are either external or internal. After enabling alarm mode, all the external alarm can be check by raising these from krone box. Syntax & Massage after execution of this command is shown below:
MMI-RAM 1015 -> alarm_mode 30 on SITE ---30 MODE --------------------------------------Alarm reporting enabled
When Opto 1 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (16) Optocoupler 1 -- Severity: CRITICAL Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:00:04:000 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: High Room Temp (0)
When Opto 1 alarm clear from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (16) Optocoupler 1 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:00:19:280 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: High Room Temp (0)
When Opto 2 alarm raised from Krone box. A massage is appearing on the screen as shown below.
12
* Device Alarm -- Untagged * * (17) Optocoupler 2 * -- Severity: MAJOR Category: ENVIRONMENT * -- EAS 0 0 0 * -- Site: 30 Cage: 15 Slot: 16 * -- Functional Unit: Site 30 * -- Time: Wed 8/9/2004 21:00:19:000 * -- Alarm Type: Fault Management Initiated Clear * -- Additional Info: Site on Battery (1) When Opto 2 alarm clear from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (17) Optocoupler 2 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:00:34:440 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Site on Battery (1)
When Opto 3 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (18) Optocoupler 3 -- Severity: MAJOR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:00:34:000 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: 1 Rect. Fail (2)
When Opto 3 alarm clear from Krone box. A massage is appearing on the screen as shown below. * Device Alarm -- Untagged * * (18) Optocoupler 3 * -- Severity: CLEAR Category: ENVIRONMENT * -- EAS 0 0 0 * -- Site: 30 Cage: 15 Slot: 16 * -- Functional Unit: Site 30
13
When Opto 4 alarm clear from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (19) Optocoupler 4 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:01:30:540 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Fire At Site (3)
When Opto 5 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (20) Optocoupler 5 -- Severity: MAJOR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 20:43:01:000 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Load on Diesel Gen. (4)
When Opto 5 alarm clear from Krone box. A massage is appearing on the screen as shown below.
14
* * * * * * * * * *
Device Alarm -- Untagged (20) Optocoupler 5 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 20:43:16:560 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Load on Diesel Gen. (4)
When Opto 6 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (21) Optocoupler 6 -- Severity: MAJOR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:01:31:000 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Air Conditioner Failure (5)
When Opto 6 alarm clear from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (21) Optocoupler 6 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:01:46:620 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Air Conditioner Failure (5)
When Opto 7 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * Device Alarm -- Untagged (22) Optocoupler 7 -- Severity: CRITICAL -- EAS 0 0 0
Category: ENVIRONMENT
15
When Opto 8 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (23) Optocoupler 8 -- Severity: MAJOR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:02:01:000 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Low Diesel Level (7)
When Opto 8 alarm clear from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (23) Optocoupler 8 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 0 0 0 -- Site: 30 Cage: 15 Slot: 16 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:02:16:940 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: Low Diesel Level (7)
16
When Opto 9 alarm clear from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (16) Optocoupler 1 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 1 0 0 -- Site: 30 Cage: 15 Slot: 17 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:02:33:030 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: DG on NO LOAD (6)
When Opto 10 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (17) Optocoupler 2 -- Severity: MINOR Category: ENVIRONMENT -- EAS 1 0 0 -- Site: 30 Cage: 15 Slot: 17 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:02:33:000 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: DG FAIL to START (9)
When Opto 10 alarm clear from Krone box. A massage is appearing on the screen as shown below. * Device Alarm -- Untagged * * (17) Optocoupler 2
17
When Opto 11 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (18) Optocoupler 3 -- Severity: MINOR Category: ENVIRONMENT -- EAS 1 0 0 -- Site: 30 Cage: 15 Slot: 17 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:02:48:000 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: CIRCUIT BREAKER FAILURE (10)
When Opto 11 alarm clear from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * * * Device Alarm -- Untagged (18) Optocoupler 3 -- Severity: CLEAR Category: ENVIRONMENT -- EAS 1 0 0 -- Site: 30 Cage: 15 Slot: 17 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 21:03:03:350 -- Alarm Type: Fault Management Initiated Clear -- Additional Info: CIRCUIT BREAKER FAILURE (10)
When Opto 12 alarm raised from Krone box. A massage is appearing on the screen as shown below. * * * * * * * * Device Alarm -- Untagged (19) Optocoupler 4 -- Severity: MAJOR Category: ENVIRONMENT -- EAS 1 0 0 -- Site: 30 Cage: 15 Slot: 17 -- Functional Unit: Site 30 -- Time: Wed 8/9/2004 20:37:58:000
18
14.
alarm_mode (site number) off This command is used to disable alarm mode.
C.
D.
19
Commissioning Procedure for Motorola BTS E. Press UFor Up Calibration offset DFor Down Calibration offset
Until the desired power is reached i.e 20W, note down the Calibration offset
F.
G.
(i) H. I. J. K. L.
SAVE CAL TX
Connect the serial cable to the MMI port Give the hard reset to the carrier unit Check the cal data, when the carrier unit is busy The cal data should be same as entered by you Repeat the action for all carrier units
B. C.
Unlock the carrier unit which is to be calibrate Connect the serial cable to the carrier unit
D.
20
E.
F.
G.
H. I. J. K. L. M. N. O. P.
Connect the serial cable to the MMI port and lock the carrier unit Now gives the hard reset to the carrier unit Lock both the dri in the carrier unit Unlock both the dri in the carrier unit Check the cal data of the both dri when it is busy The cal data must be (12+X), where X = offset given by you The cal data shown in hexadecimal value Only one dri is calibrate in one CTU, other dri automatically taken the value for first dri Now repeat the action for the all carrier units
21
C.
D.
chg pizza cal_test_mode on fm test_mode on fm_test block none 0xff cal_config tx_cab_mode single cal_cabinet tx_cab
E.
Connect the serial cable to the MMI port and lock the carrier unit Now gives the hard reset to the carrier unit Lock the carrier unit Connect the power meter and then Unlock the carrier unit till dri is busy and then gives the BCCH channels to this dri. Check the power on the power meter if it is 20Watt then ok, otherwise observe either power is less then 20 Watt or more then 20 Watt. If it is less then 20 Watt then again dummy calibrate and set offset below 16 value. If it is more then 20 Watt then again dummy calibrate and set offset beyond 16 value.
22
D.
E.
F.
G.
H.
23
I.
J. K. L. M.
(i) HALT C (ii) WRENB (iii) SAVE CAL TX (iv) WRPTC Connect the serial cable to the MMI port Give the hard reset to the carrier unit Check the cal data of the carrier when it is busy Repeat the action for the all carrier units
24