Veritas Quick Start Guide Userguides
Veritas Quick Start Guide Userguides
Veritas Quick Start Guide Userguides
The Veritas is an 8 zone panel, which can be used out of the box with a minimum of additional programming. This document is designed for use with all of the Veritas variants and describes how to use the product with its default settings for an out of the box solution. The following paragraphs provide a quick start description of how to set up a simple alarm system, more detailed descriptions are provided in the installation manual and these are cross referenced below where they may be of use.
Installation
Select suitable locations for the panel, keypad, detection devices and bell box, fix each device to the wall in its selected location and run cables from the panel to each device as follows.
Veritas Control Panel. Veritas Keypad (some panels have built in keypads). Detection Devices. Bell Box (Odyssey described here). Mains Supply (Fused Spur).
Connect the detection devices to the zone connections in the panel. Refer to Zone Connections in the Installation section (section 3) of the installation manual for details of how to wire detection devices to zones. The Veritas has a global tamper circuit, all of the detector tampers will need to be connected in series before being connected to the global tamper terminals. See Global System Tamper in the Installation section (section 3) of the installation manual. If more than one remote keypad is fitted, the keypads will need to be addressed, see Installing Remote Keypads in the Installation section of the manual. The panel will require a mains supply, connect mains via a fused spur as described in Connecting AC Mains in the Installation section of the installation manual.
In part set, Zone 1 becomes a full guard (instant alarm) and Zone 2 becomes entry exit. This can be changed using programming options 21 and 23.
The keypad should be mounted at a convenient location, easily accessible from the normal entrance and from the sleeping quarters in a domestic installation. The bell box should normally be mounted so that it is visible when approaching the entrance. After an alarm the strobe will continue to flash after the bell cut off, warning the occupant that intruders may be on the premises.
Applying Power
On first power up, the Veritas should be defaulted. To default the panel on power up do the following: Connect mains to the panel, then within 10 secconds (while all zone lights are lit) press the reset button on the keypad twice. After a few more seconds the zone lights will go out and the panel will start to set enter your default user code ( ) to stop the system from setting and silence it. Once the panel has been defaulted and silenced as described above, connect the backup battery.