MOS For Drainage Pipe Installation
MOS For Drainage Pipe Installation
MOS For Drainage Pipe Installation
8. (onnection of drainage pipes other than water closet drain (i.e. %'( drain" lavatory drain" bidet drain" bathtub drain and shower tray drain) should be slope toward gully trap floor drain based on the approved toilet details shop drawings. 17. 9ipes and pipe fittings connection should be on the compacted fine sand and partly small of cement mortar as its support. #eight distance between gully trap bottom and slab should be two ( ) centimeter for all toilets. 11. %bsolute care should be imposed not to damage the water proofing upon installation. 1 . 5nstall sleeves for pipes passing through the concrete or masonry walls. 9ut sealant in between the pipes and sleeves. 1$. (heck the pipes securely fixed" 0oint and capped before leak testing. 1). 3eak test for the installed pipes is to be carried+out with presence of inspector :ngineer. 1,. %fter the approval of 5nspector :ngineer" cover the pipes with cement plaster or sand to where it is applicable. END