Connectors
ANSI Code
ANSI MC 96.1 Colour Coding
Thermocouple Grade Extension Grade
Connectors
Alloy Combination
+ Lead
IRON Fe (magnetic)
Lead
CONSTANTAN COPPERNICKEL Cu-Ni ALOMEGA NICKELALUMINUM Ni-AI (magnetic)
EMF (mV) IEC 584-3 Over Max Colour Coding Temp Thermocouple Intrinsically Range Grade Safe
IEC Code
J K T E N R S U B
(W)
NONE ESTABLISHED
8.095 to 69.553
J K T E N R S U
Clean Oxidising and Inert. Limited Use in Vacuum or Reducing. Wide 270 to 1372C Temperature 454 to 2501F Range, Most Popular Calibration Mild Oxidising,
6.458 to 54.886
COPPER Cu
Reducing Vacuum or CONSTANTAN Inert. Good Where COPPER270 to 400C Moisture Is Present. Low NICKEL Temperature & Cryogenic 454 to 752F CuNi Applications
6.258 to 20.872
CONSTANTAN Limited Use in Vacuum or 270 to 1000C COPPERReducing. Highest EMF 454 to 1832F Change NICKEL Per Degree Cu-Ni OMEGA-N NISIL Ni-Si-Mg
Alternative to Type K. More Stable at High Temps Oxidising or Inert. Do Not Insert in Metal Tubes. Beware of Contamination. High Temperature Oxidising or Inert. Do Not Insert in Metal Tubes. Beware of Contamination. High Temperature Extension Grade Connecting Wire for R & S Thermocouples, Also Known as RX & SX Extension Wire. Oxidising or Inert. Do Not Insert in Metal
Oxidising or Inert.
9.835 to 76.373
4.345 to 47.513
PLATINUM Pt
50 to 1768C 58 to 3214F
0.226 to 21.101
NONE ESTABLISHED
PLATINUM Pt
50 to 1768C 58 to 3214F
0.236 to 18.693
NONE ESTABLISHED
COPPER Cu
NONE ESTABLISHED
PLATINUMTubes. Beware of PLATINUMContamination. 30% RHODIUM 6% RHODIUM High Temp. Common Use Pt-30% Rh Pt-6% Rh in Glass Industry
Vacuum, Inert, Hydrogen. Beware of Embrittlement. Not Practical Below 399C (750F). Not for Oxidising Atmosphere Vacuum, Inert, Hydrogen.
0 to 1820C 32 to 3308F
0 to 13.820
B
NO STANDARD USE ANSI COLOUR CODE
G* C* D*
NONE ESTABLISHED
TUNGSTEN W
0 to 2320C 32 to 4208F
0 to 38.564
G C D
NONE ESTABLISHED
(W5) (W3)
TUNGSTENTUNGSTEN- Beware of Embrittlement. Not Practical Below 5% RHENIUM 26% RHENIUM 399C (750F) W-5% Re W-26% Re
Not for Oxidising Atmosphere
0 to 2320C 32 to 4208F
0 to 37.066
NONE ESTABLISHED
of Embrittlement. TUNGSTENTUNGSTEN- Beware Not Practical Below 3% RHENIUM 25% RHENIUM 399C (750F)Not for W-3% Re W-25% Re Oxidising Atmosphere
0 to 2320C 32 to 4208F
0 to 39.506
190