SMARTER COPPER TESTING FOR INSTALLATION TECHNICIANS

Smarter verication of copper pairs and location of faults during the installation and repair of voice and DSL circuits.

KEY FEATURES AND BENEFITS


Focus on single-ended testing minimizes repair time and costs Full suite of digital multimeter measurements to quickly and effectively determine the electrical health of the network Optional TDR and RFL allow service providers to scale the product based on existing or new methods and procedures SmartR features allow users to quickly and accurately determine physical copper circuit quality and locate faults Designed to face the challenges of the outside plant environment with an IEC IP54 rating Congurable pass/fail results for automated testing

THE MAXTESTER 600 SERIES

MAX-630
xDSL and Multiplay Test Set

MAX-635
Copper, xDSL and Multiplay Test Set

SPEC SHEET

MaxTester 610

THE PERFECT TOOL FOR COPPER I&R TESTING


EXFOs MaxTester 610 is designed for the installation and repair (I&R) of voice and DSL circuits. Its small form factor, rugged design and easy-to-use menus make it the ideal tool for outsideplant I&R technicians. With the MaxTester 610, the testing process is highly automated, enabling technicians to close their jobs quickly and efficiently. In addition, the large display of the MaxTester 610 makes it even more user-friendly, and when it comes to saving results, it provides technicians with many connectivity options for uploading tests and compiling reports.

THE MAXTESTER 610 JOINS FORCES WITH SMARTR


The MaxTester 610 allows technicians and engineers alike to work smarternot harder. SmartR is a suite of intelligent and automated tests that enable any technician to quickly and easily gain an understanding of the condition of the line under test, as well as to identify and locate a variety of common circuit faults. The Pair Detective feature automatically runs the most common line tests and provides graphical, color-coded results and pass/fail indications to detect conditions, including shorts, grounds, opens, battery, splits and imbalances. FaultMapper utilizes time-domain reflectometry (TDR) and frequency-domain reflectometry (FDR) technology to provide the additional capability of identifying the location of the service affecting line faults, including bridged taps, shorts, grounds and opens. EXFOs unique SmartR presents results in an easy-to-understand, graphical format, making copper troubleshooting easier than ever before.

KEY COPPER APPLICATIONS


error-free multiplay services (8, 12, 17 and 30 MHz) prequalification

Detection of potential bottlenecks on subscriber loops to ensure high-quality, consistent and 30 MHz spectrum analysis for circuit qualification in any VDSL2 band plan Loop and fault analysis, using proven TDR and FDR techniques for VDSL2 or ADSL2+ Measurement and reporting of suspect voltages, opens and shorts
KEY CHARACTERISTICS
1
4
1 Ethernet connector sealed
against the environment

2 Copper connectors sealed

5 3

against the environment

3 All-round rubber bumper 4 Large 6 in daylight-visible


color LCD

5 Interface connections

6 2 7

water and dirt protected

6 Innovative and icon-driven


user interface

7 Handgrip area 8 Simple keypad

MaxTester 610

COMPREHENSIVE METALLIC TESTING


Verification of copper quality is a snap with the copper measurement capabilities of the MaxTester 610. Sporting industry standard AC and DC voltage measurements, resistance (shorts) and capacitance (opens) measurements, power influence and impulse noise, technicians obtain results that are graphically clear and concise with pass/fail indication. The MaxTester 610 also features a POTS dialer and an optional TDR and resistive fault locator (RFL) for locating loop faults. The optional wideband testing suite allows the qualification of circuits at VDSL2 frequencies of up to 30 MHz and includes PSD, impulse noise and attenuation analysis.

ALL THE RIGHT FEATURES FOR INSTALLATION TECHNICIANS


With its small form factor, the MaxTester 610 can go anywhere technicians need to go. It is rugged and light, and all connectors are protected from the rainjust what is needed for the demanding outside-plant environment.

Automated Testing
Thresholds can be set and saved for key copper tests. When tests are run, users are given a clear graphical pass/fail result so they can quickly move on to the next job or investigate further. Test profiles can easily be transferred between units to ensure that all technicians from the same organization are testing to the same thresholds.

Easy-to-Use GUI
The next-generation user interface of the MaxTester 610 was designed with first-level technicians in mind. The large display features colored icons and graphics for easy configuration and operation, and is simple to use for both experienced and novice users.

Results Capture and Connectivity


In todays highly competitive environment, quality of service is paramount for service providers. The MaxTester 610 allows reports of all tests to be saved and uploaded. Therefore, service providers can keep all the results on file for future reference and confirm that all the required tests have been completed by the technician.

Battery-Powered
The MaxTester 610 is equipped with a battery using the latest technology in rechargeable cells. When charging is required, technicians can either use the optional 12 V vehicle charger or the supplied AC adapter.

MaxTester 610 COPPER SPECIFICATIONS a, b, c


Receiver characteristics Reception frequency Frequency accuracy VF reception level range (dBm) VF level accuracy 200 Hz to 20 kHz 20 kHz to 30 MHz (50 ppm + 1 digit) 90 to 20 at 600 200 Hz to 20 kHz 90 dBm to 50 dBm, accuracy 2 dB 50 dBm to 20 dBm, accuracy 1 dB 90 to 14 dBm at 100 and 135 20 kHz to 2.2 MHz 90 dBm to 50 dBm, accuracy 2 dB 50 dBm to 14 dBm, accuracy 2 dB 2.2 MHz to 30 MHz 90 dBm to 50 dBm, accuracy 2 dB 50 dBm to 14 dBm, accuracy 2 dB Impedance () POTS dialer DTMF Phonebook Digital multimeter (DMM) Test type Impedance selection (for voltage measurement) Measurement DC voltage AC voltage Isolation resistance (stress/leakage) Range 0 to 400 V 0 to 280 Vrms 0 to 1 G, auto-ranging 0 to 999 1 k to 99 M 100 M to 999 M 0 to 100 M 0 to 999 1 k to 100 M 0.1 nF to 2 F 0 to 110 mA 0 to 110 mA 100, 135, 600 0 9, #,* 25 entries Snapshot and continuous 100 k, 1 M Resolution 0.1 V for 0 to 99.9 V 1 V for 100 V to 400 V 0.1 V for 0 to 99.9 V 1 V for 100 V to 280 V Three digits (2 % + 5 ohms) (2 % + 1 digit) (5 % + 1 digit) Three digits (1 % + 5 ohms) (2 % + 1 digit) Three digits 0.1 mA 0.1 mA (2 % + 50 pF) (2 % + 1 mA) (2 % + 1 mA) d Accuracy the smaller of (1 % + 0.5 VDC) or 1 VDC the smaller of (1 % + 0.5 VAC) or 1 VAC

WB reception level range (dBm) WB level accuracy

Resistance

Capacitance DC current AC current Isolation resistance (stress/leakage) (continued) Source Soak timer (s)
NOTES a. Preliminary and subject to change without notice. b. Typical, at 23C 1C, on batteries, with no type B USB connection. c. Specifications based on 24 AWG (0.5 PE mm) cabling. d. From 10 mA to 110 mA.

50 to 125 VDC (current safely limited to 0.5 mA) 1 to 60

MaxTester 610 COPPER SPECIFICATIONS a, b, c (continued)


VF noise measurement Frequency range Level range (dBm) Resolution (dB) Accuracy Filters Impedance VF impulse noise Low threshold (dBm) Mid threshold High threshold Separation (dB) Dead time (ms) Filters Counter Timer Power influence (noise to ground) Noise range (dBm) Accuracy VF longitudinal balance Frequency (Hz) Level range (dB) Level accuracy (dB) Impedance Time-domain reflectometer (TDR) Modes Distance range (m) Pulse width Test signals Amplitude Velocity of propagation (VOP) Distance accuracy (m) Units Load coil detection Count Plot (kHz) Distance range (m)
NOTES a. Preliminary and subject to change without notice. b. Typical, at 23C 1C, on batteries, with no type B USB connection. c. Specifications based on 24 AWG (0.5 PE mm) cabling. d. Qualified up to 300 m (1000 ft) and does not include the uncertainty due to VOP.
d

200 Hz to 20 kHz +20 to 90 0.1 90 dBm to 50 dBm, accuracy 2 dB 50 dBm to +20 dBm, accuracy 1 dB ITU: none, psophometric, P-notched, 3.4 kHz, D-filter, 15 kHz ANSI: none, C-message, C-notched, 3.4 kHz, D-filter, 15 kHz 600 0 to 40, in 1 dB steps Low threshold plus separation Mid threshold plus separation 1 to 6, in 1 dB steps 125 None, 3 kHz flat, C-message, psophometric, notched and D filter (IEEE 743-1995) Maximum 999 for each threshold 1 minute to 24 hours, default is 15 minutes 60 to +10 60 dBm to 50 dBm 2 dB 50 dBm to 10 dBm 1 dB 1004 0 to 100 1 600 Fully automatic operation with location of most significant event(s) 0 to 6700 (0 ft up to 22 000 ft) 15 ns to 20 s Sine wave, compensated sine wave, half-sine wave and square wave 7.5 V p-p on cable, 9 V p-p open circuit 0.400 to 0.999 (0.5 m + 1 % x distance) Meters and feet Up to 5 Up to 10 Up to 8000 (up to 27 000 ft)

MaxTester 610 COPPER SPECIFICATIONS a, b, c (continued)


Power spectral density (PSD) Test type Vertical scale Horizontal scale Noise filters Wideband impulse noise Threshold Counter maximum Test duration Accuracy (dB) Wideband longitudinal balance Level range (dB) Level resolution (dB) Level accuracy (dB) Frequency accuracy (ppm) Frequency scale Resistive fault location (RFL) Test type Fault detection (M) Resolution Loop resistance (k) Multiple cable sections Fault location Continuous with peak-hold 15 dBm/Hz to 140 dBm/Hz or 14 dBm to 90 dBm 4.3125 kHz to 17 MHz, in 4.3125 kHz steps or 8.625 kHz to 30 MHz, in 8.625 kHz steps None or E, F, G, VDSL2-8, VDSL2-12, VDSL2-17 and VDSL2-30 50 dBm (40 dBrn) to 0 dBm (90 dBrn) in 1 dB steps 65 000 000 1, 5, 10, 15 and 60 min, 24 h or continuous 2 0 to 50 up to 2.2 MHz 0 to 40 up to 12 MHz 0.1 2 (up to 2.2 MHz) (50 ppm + 1 digit) ADSL/2+: 20 kHz to 2.2 MHz VDSL/VDSL2-12: 20 kHz to 12 MHz Single pair (two wire) and separate good pair (four wire) 0 to 20 Three digits 10 maximum Five (includes gauge and temperature setting) Total resistance, near-end to fault resistance, fault to strap resistance (three significant digits, least significant digit 0.1 ). Total length, distance to fault, distance from fault to strap (three significant digits, least significant digit 1 m) Accuracy
NOTES a. Preliminary and subject to change without notice. b. Typical, at 23C 1C, on batteries, with no type B USB connection.. c. Specifications based on 24 AWG (0.5 PE mm) cabling.

(1 % + 0.1 + (RF/5 M)%)

MaxTester 610 GENERAL SPECIFICATIONS


Display TFT LCD with backlight 152 mm (6 in) diagonal 800 x 480 resolution, WVGA Five-color banana connector for T/B, R/A, G, T1/B1, R1/A1 1.2 GB internal memory

Test connections Results storage Temperature range operating storage Humidity Shock Altitude Input power Battery Safety Size (H x W x D) Weight (with battery) Water/dust ingress Differential voltage protection Common mode voltage protection Voltage detection Self-test Connectivity Languages

0 C to 40 C (32 F to 104 F) 20 C to 60 C (4 F to 140 F) 5 % to 95 % relative, non-condensing 1 m (39 in) drop per GR-196-CORE 3000 m (9842 ft) 9-24 VDC, 2A, 18 W via 90-220 VAC adapter or 12 V vehicle adapter Internal rechargeable lithium polymer, with battery-state and level indications, ajustable auto-power down CE and CSA marked 254 mm x 124 mm x 62 mm (10 in x 4 7/8 in x 2 7/16 in) 1.5 kg (3.3 lb) Designed to comply with IP54 125 Vrms or 400 VDC max 1000 Vrms > 20 V will trigger alarm message Routine on power-up Two USB 2.0 client ports One USB Type B host port English, French, Spanish, Chinese (Simplified)

STANDARD ACCESSORIES
Test cable: Three-color (black, red, green) 4 mm banana plugs terminated with telco clips (ACC-M3COLR), or Three-color (black, red, green) 4 mm banana plugs terminated with 4 mm plugs with crocodile clips (ACC-M4MM) RFL strap (ACC-STRP) Certificate of compliance AC adapter (GP-2146) Soft carrying case (GP-10-061)

OPTIONAL ACCESSORIES
Copper test cables: Yellow/blue banana connectors to telco clips (ACC-MTCYB) or Yellow/blue banana connectors to 4 mm plugs/croc clips (ACC-M4MMYB) USB host/client cable (GP-2053) 16 GB USB memory stick (GP-2144) 12 V vehicle charger (CL4-CAR) Form fitting, protective soft glove with shoulder strap (ACC-GLOVE)

MaxTester 610 ORDERING INFORMATION


MAX-610-XX
Model MAX-610 = Copper I&R test set Copper Software Options 00 = Without software options TDR = Time-domain reflectometry option RFL = Resistive fault location option WBAND = Extend frequency testing to 30 MHz SMARTR = Pair Detective and FaultMapper option a

Example: MAX-610-TDR-SMARTR
Note a. Includes TDR option.

EXFO Corporate Headquarters > 400 Godin Avenue, Quebec City (Quebec) G1M 2K2 CANADA | Tel.: +1 418 683-0211 | Fax: +1 418 683-2170 | [email protected] Toll-free: +1 800 663-3936 (USA and Canada) | www.EXFO.com
EXFO America EXFO Asia EXFO China EXFO Europe EXFO Finland EXFO Service Assurance 3400 Waterview Parkway, Suite 100 100 Beach Road, #22-01/03 Shaw Tower 36 North, 3rd Ring Road East, Dongcheng District Room 1207, Tower C, Global Trade Center Omega Enterprise Park, Electron Way Elektroniikkatie 2 270 Billerica Road Richardson, TX 75080 USA SINGAPORE 189702 Beijing 100013 P. R. CHINA Chandlers Ford, Hampshire S053 4SE ENGLAND FI-90590 Oulu, FINLAND Chelmsford, MA 01824 USA Tel.: +1 972 761-9271 Tel.: +65 6333 8241 Tel.: + 86 10 5825 7755 Tel.: +44 23 8024 6810 Tel.: +358 (0)403 010 300 Tel.: +1 978 367-5600 Fax: +1 972 761-9067 Fax: +65 6333 8242 Fax: +86 10 5825 7722 Fax: +44 23 8024 6801 Fax: +358 (0)8 564 5203 Fax: +1 978 367-5700

EXFO is certified ISO 9001 and attests to the quality of these products. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. EXFO has made every effort to ensure that the information contained in this specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify design, characteristics and products at any time without obligation. Units of measurement in this document conform to SI standards and practices. In addition, all of EXFOs manufactured products are compliant with the European Unions WEEE directive. For more information, please visit www.EXFO.com/recycle. Contact EXFO for prices and availability or to obtain the phone number of your local EXFO distributor. For the most recent version of this spec sheet, please go to the EXFO website at www.EXFO.com/specs. In case of discrepancy, the Web version takes precedence over any printed literature.

SPMAXTESTER610.1AN

2012 EXFO Inc. All rights reserved.

2008

Printed in Canada 12/05

You might also like