Circuit Protection Selection: Fuji Electric Ul 489 Rated Molded Case Circuit Breakers (MCCBS)
Circuit Protection Selection: Fuji Electric Ul 489 Rated Molded Case Circuit Breakers (MCCBS)
00
starting at
BW Series Fuji Molded Case Circuit Breakers are more compact (especially 100A, 125A, 250A frames) than any breakers on the market, so control panels take up less space than ever before. This product group maintains conformity to all Worldwide standards, including cULus / IEC / CE Marking / JIS (Japan) / CCC (China). Suitable for branch circuit protection 5 frame sizes, rated current of 15 to 800A, max 600V Standard type and high-interrupting capacities are available in identically sized breakers Shunt Trip, Undervoltage Release and other accessories are available Auxiliary Switch and Shunt Trip can be installed in the field
Circuit
The 3P series provides branch and feeder circuit protection in industrial control panels.
$16.50
starting at
$192.00
starting at
The WMZT series is DIN-rail mountable and can be used in branch circuit application up to 40 amps and are available with C or D trip characteristics.
Short circuit and ground fault protection for feeder and branch circuits Motor disconnecting means (NEC 430.101-430.113) Motor branch-circuit short circuit protection (NEC 430.51-430.58) Motor controller (NEC 430.81-430.91) Motor overload protection (NEC 430.21-430.44) OSHA Lockout/tagout disconnect (NEC 430.81-430.91)
NO
NO
NO NO
NO
UL 98
MOTOR CIRCUIT
NO NO NO NO NO
NO
NO
NO
NO
NO NO NO NO
UL 508
Motor overload protection (NEC 430.21-430.44) OSHA Lockout/tagout disconnect (NEC 430.81430.91)
YES YES
NO YES
Motor
1 - 80 0 - 633 - 0405
Volume 13
e31-2
Circuit Protection
Protection
Mersen UL 98 Rated Disconnect Switches
SC series FB series
Heavy-duty fusible and non-fusible disconnects meet all the requirements of the UL 98 standard. These switches can be used as a motor disconnecting means to meet NEC 430.109; meets NEC 430.111 as a motor controller. Non-fusible rotary disconnect switches Makes/breaks loads up to 800 amps Front operated Visible blade contacts Line-side shrouding comes standard with switch Fusible rotary disconnect switches Makes/breaks loads up to 200 amps Front operated Uses Class CC and Class J fuses Line side shrouding comes standard with switch Touch-safe fuse covers standard with switch
Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters
$82.00
starting at
Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pressure Sensors
$18.00
starting at
Lockout / Tagout capability and finger safe construction Positive visible circuit isolation via the disconnect switch Uses only 1/3 the space of a molded circuit breaker and 2/3 the space of a traditional fusible switch
The SD series of load switches are used for making and breaking equipment loads. These switches can be used as a motor controller meeting NEC 430, Part VII. Typical applications include local motor isolation.
$22.50
starting at
Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index
35mm DIN rail mountable or direct mountable Loads from 16 to 125 amps IP20 degree of protection
$33.00
starting at
for 10-pack
NEW! High-speed Class J (JHL) combines electronic and motor branch circuit protection in one fuse.
Industry standard extremely fast-acting, single element Class T and dual element time delay Class RK5, RK1, and Class J current limiting short circuit protection is available up to 600 amps.
$6.50
starting at p/n TJS1-1
These fuses are recommended for AC power distribution feeder and branch circuits; they provide ideal protection for motors and all general purpose applications including lighting, heating, inductive and non-inductive loads.
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
e31-3
Circuit Protection
Supplementary Protection Selection
General
Fuses UL 248-14
(continued)
We carry industry standard current limiting class CC, general purpose class M (Midget) and small dimension glass and ceramic circuit protection, fuse holders and accessories. They provide ideal supplementary protection up to 30 amps to branch circuits and end of line equipment.
CONTROL CIRCUIT
PLC I/O
Control Transformer
YES
Contactor Coils Relays
YES
$1.75
starting at begin on page 31-111
for 5-pack
$8.00
starting at begin on page 31-56
Circuit Protection
from
Supplementary protectors are UL 1077 recognized and are used in applications where branch circuit protection is not required or is already provided. WMZS Series DIN rail mountable Full line of auxiliary switches, alarm switches and padlock lockout accessories B trip curve 6 to 60 amps C trip curve 0.5 to 60 amps D trip curve 0.5 to 40 amps
UL489 or UL1077?
Company Information Systems Overview Programmable Controllers Field I/O Software C-more & other HMI Drives Soft Starters Motors & Gearbox Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors
Branch Protection
UL489
Supplementary Protection
UL1077
Branch Protection
UL489 Listed or Recognized CSA C22.2 No. 5 International ratings available depending on breaker type
UL489
Supplementary Protection
UL Recognized under UL1077 CSA 22.2 No. 285 IEC 60947-2 or IEC 898
UL1077
Pressure Sensors Temperature Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. Terminal Blocks & Wiring Power Circuit Protection Enclosures Tools Pneumatics Appendix Product Index Part # Index
Function
Opens automatically on Overload and Short Circuit Opens automatically on Overload and Short Circuit when properly applied with Provides additional equipment protection where branch circuit protection is in its ratings already provided or not required Protects wire and cable against Overload and Short Circuit Not suitable for the protection of branch circuit conductors
Applications
Branch circuit protection in control panels, panelboards, switchboards and motor control centers Motor overload and motor short circuit protection (UL489 Recognized motor circuit protectors) for control panels and motor control centers Used within appliances or other electrical equipment such as control circuits, control power transformers, relays, PLC I/O points and lighting circuits Ideal replacement for fuses that are applied as supplementary protection
Features
Bolted down or DIN-rail mounted External handle mechanisms available Field mounted accessories Stand alone branch circuit protection Various levels of protection (curve type) High voltage and interruption levels (up to 100 kAIC @ 480V) DIN-Rail mounted Field mounted accessories Current limiting Various levels of protection (curve type) 10 kAIC @ 240 VAC 6 kAIC @ 277 VAC and 5 kAIC @ 480 VAC 10 kAIC @ 65 VDC kAIC = thousands of Amps interrupt capacity
Summary
A Supplementary Protector cant Be used for Branch Circuit Protection. Understanding the difference between Branch Circuit Protection and Supplementary Protection helps to ensure their proper use.
Volume 13
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
e315