WALLFI
WALLFI
WALLFI
Ver.02
1. DESCRIPTION
Wall-Fi is an interface intended to be used together with Microsol II plus from version 2. It enables easy and quick remote access to all Microsol II plus information and setup.
back to the previous menu or to leave any function without confirming press are available in the function menu:
01-Setpoint A1
2. APPLICATION
Solar heating controlling.
02-Setpoint A2
3. TECHNICAL SPECIFICATIONS
- Power supply: 90 - 264 Vac (50/60 Hz) - Size: 90 x 131 x 28 mm (W x H x D) - Operating temperature: 0 to 50C - Operating humidity: 10 to 90% RH (no condensation) - Data communication: By radio frequency - maximum distance of 50 meters without obstacles -Routers: For installations requiring the use of the FG-Wi Router, a maximum of 16 routers can be installed.
4. MAIN SCREEN
The figure below shows the main screen of Wall-Fi with the system in operation. Preferential indication description
05-Clock
The access code 123 must be entered in this screen to enable changing functions of remote Microsol II plus controller. To enter the code press on the message and adjust the value that will be blinking on the display. Press again to confirm; to cancel and go back press .
5.2 Functions
In this screen all functions of remote Microsol II plus can be adjusted. To make changes press on the desired function and enter the value that will be blinking on the display. Press again to confirm the new value; to cancel and go back press . Function description
8. SETUP MENU
The operating characteristics of Wall-Fi can be adjusted through the setup menu. To access the function menu press and keys simultaneously for eight seconds until the functions are shown in the display. The following options are available in the setup menu:
Function code
07-Routes 08-Statistics
02-Interface 03-Descriptions
8.1 McSol2 485 Add
This function allows to manually adjusting the address of the remote Microsol II plus controller. The value set for this function should be the same value set on the remote Microsol II plus.
8.2 Interface
Allows adjusting the user interface characteristics:
Fun Descrio Indication Language Display contrast Display timeout Sound signaling Mn. S1 0 0 Off Mx. All 10 999 On Unid min. Padro S2 Port 5 0 Off
WALLFI02-02T-11782
Sensor 2 26.9$C
Distribution box
A B A B A B
RS-485
PUMP AUX 1
MICROSOL II plus
Wall-Fi
Microsol II remote
8.5 RF Config
This function allows adjusting the wireless network address and channel. First, place the Slave FG-Wi Converter (which is connected to the remote Microsol II plus) into setup mode. To perform this operation, just set to its lower position the switch located on the converter rear panel, and wait until the led starts flashing. Press the key in the Wall-Fi function, enter the network address, and channel values. Confirm both values by pressing . After the channel confirmation, the Wall-Fi will start sending the configuration. Confirm that both TX and RX leds remain lit on the Slave FG-Wi. This indicates that the device correctly received the configuration. Then, set its switch to the normal operation position. After this procedure, press in the Wall-Fi, so it returns to the setup menu.
Sensor 2 26.9$C
RS-485
8.7 Routes
This function allows individually configuring the route (path) through the routers (FG-Wi Router units) that the wireless communication will follow, to reach the Slave FG-Wi connected to the remote Microsol II plus. When accessing this function, it should be entered the addresses of the routers that make up the route from the Wall-Fi to the Slave FG-Wi. A maximum of 16 FG-Wi Router units can be used per route. If no router is used on the network, all the routes should be configured with the "Off" setting.
IMPORTANT According to NBR5410 and IEC60364 standards: Install protectors against overloads on power supply. For more information contact our application eng. department through e-mail [email protected] or dial +55 51 3475 3308.
8.8 Statistics
This function allows viewing on-screen statistics on wireless communication, by displaying the number of errors in requesting data from the remote Microsol II plus (Scan Err) and the number of errors in sending functions (Rx Err).
9. Other views
Pressing the key repeatedly you can view other information from the remote Microsol II plus. The selected visualization will remain on the display for 10 seconds and after this time it will return to the main screen. The options available are:
Time
Tuesday 14:19 Pump Aux1 Aux2 % $ %& Aux 1status $ Output off; % Output on; $& Manual operated output off; %& Manual operated output on;
Aux 2 status
10. INDICATORS
Alarm of minimum temperature on the sensor S1 Alarm of maximum temperature on the sensor S1 Wall-Fi is unable to locate remote Microsol II plus at address 1; High temperature alarm; Freezing temperature alarm; Sensor disconnected.
ENGLISH