SPC232SF SPmode
SPC232SF SPmode
11/17/2011
Service Menu
"Special Mode" is needed to input the serial number after the Engine Board EEPROM
SM Appendix
4-1
M018/M019
Service Menu
Menu List
Display Info Model Name CTL FW Ver. FW Ver. FAX FW Ver. MCTL FW Ver. PDL FW Ver. Printer Counter Displays the Model Name, Depends on Engine Firmware Settings Displays the Firmware Version Displays the PDL Firmware Version. Displays the Engine Firmware Version Displays the PDL Firmware Version. Displays the following counters of the printer engine. Total Page/ Color Image/ Black Image Displays the sum total of scanner counters for each mode. Total Page/ Black Page/ Color Page / ADF Used Displays the number of paper jams at each location. Total/ ADF/ Printer Output Bin/ Internal/ Tray1 / Tray2/ Duplex Coverage 1: [0 to 100 / 5 / 1/step] Coverage 2: [0 to 100 / 20 / 1/step] Changes the thresholds for each coverage counter.
Coverage 1/ Coverage 2
M018/M019
4-2
SM Appendix
Service Menu Print Reports G3 Protocol dump list G3 protocol dump of the latest communication is printed. Off (Default)/ Error/ On
Engine Maintenance Determines the maximum amount of ink/toner you can use in any area of your text. This is where you are controlling exactly how much ink will be used during printing. [200 to 400 / 250 (Default)/ 10/step] Setting 0: Off Determines the maximum amount of ink/toner you can use in any area of your graphic. This is where you are controlling exactly how much ink will be used during printing. [200 to 400 / 250 (Default)/ 10/step] Setting 0: Off Determines the maximum amount of ink/toner you can use in any area of your image. This is where you are controlling exactly how much ink will be used during printing. [200 to 400 / 250 (Default)/ 10/step] Setting 0: Off
Text
Toner Limit
Graphic
Image
PNP Name
NA Model: RICOH/ 'nul' EU Model: RICOH/ NRG/ LANIER ASIA Model: RICOH/ LANIER China Model: RICOH
SM Appendix
4-3
M018/M019
Service Menu Engine Maintenance Destination Sets the destination and updates the engine setting. JPN/ NA (Default)/ EU/ ASIA/ China 2nd Transfer Front 2nd Transfer Back 2nd Transfer Fuser Temp. Fuser Temperature Adjusts the transfer roller current, based on the default value. [-15 to 15 / 0 (Default) / 1 PA/step] Adjusts the transfer roller current, based on the default value. [-15 to 15 / 0 (Default) / 1 PA/step] Adjusts the temperature of the fusing unit, based on the default value. [-30 to 0 / 0 (Default) / 2C/step] Plain Paper (90-105 g/m2)/ Plain Paper/ Thick Paper (1405-110 g/m2)/ Thin Paper (60-75 g/2)/ Thick Paper (Post Card)/ Envelop/ Cardstock/ Bond paper/ Label Paper/ Prepunched/ Preprinted/ Letterhead/ Color/ Recycled Adjusts the horizontal registration for tray 1. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step] Adjusts the vertical registration for tray 1. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.24 mm/step] Adjusts the horizontal registration for tray 2. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step]
Media Type
Horiz. Tray1
Registration
Vert.Tray1
Horiz.Tray2
M018/M019
4-4
SM Appendix
Service Menu Engine Maintenance Vert.Tray2 Adjusts the vertical registration for tray 2. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.3 mm/step] Adjusts the horizontal registration for the bypass tray. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step] Adjusts the vertical registration for the bypass tray. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.3 mm/step] Adjusts the horizontal registration for the back side in duplex mode. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step] Adjusts the vertical registration for the back side in duplex mode. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.3 mm/step]
Horiz.Bypass
Registration Horiz.Dup.Back
Resets counters to factory defaults. Clears the Scanner and Jam Counters. Resets the maintenance counter for the fusing unit. This item appears only when the fusing unit life is almost expired or has expired.
SM Appendix
4-5
M018/M019
Vert.Bypass
Service Menu Engine Maintenance Init Engine EEPROM This clears all counters except "Full Color" and "Black and White" in the total counter. When you execute "Init Engine EEPROM", the engine EEPROM is initialized. Turn the machine power off/on after you change this setting. Displays only 1: MF2b 2: M019 Displays the current model in a dropdown list. Do not change this setting (Designed for Factory Use). 00* 7F Displays the current brand ID number. Do not change this setting (Designed for Factory Use). Input 160 bytes setting. Character: alphanumeric "0-9", "a-f", "A-F", only valid data can be input. Input length: 160 bytes
Model
Brand ID
LSU Adjustment
When you execute "Trans. Belt Adjust", the transfer belt adjustment is Trans. Belt Adjust done. This calibrates the motor speed to match the length of the new transfer belt. Fuser SC Detect On/Off* Color Registration If On, the engine detects SC559. If Off, the engine does not detect "Fusing SC Reset".
The engine will do color registration and density tuning automatically. The machine will warm up automatically after this setting is changed.
Reset Transfer Resets the transfer unit life counter. Unit Life Counter
M018/M019
4-6
SM Appendix
Service Menu Engine Maintenance Fuser SC Reset Special Mode This button is for resetting an SC related with the fusing errors.
SM Appendix
4-7
M018/M019
Service Menu Scan Maintenance Mono Compression Setting Sets the monochrome compression type for scanning. MH (Default)/ MR/ MMR ADF Main Reg. ADF Sub Reg. Regist Adjust Flatbed Main Reg. Flatbed Sub Reg. ADF Main Reg. ADF Sub Reg. Size Adjust Flatbed Main Reg. Flatbed Sub Reg. Adjusts the ADF Scan main-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the ADF Scan sub-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the Flatbed Scan main-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the Flatbed Scan sub-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the ADF Scan main-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step] Adjusts the ADF Scan sub-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step] Adjusts the Flatbed Scan main-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step] Adjusts the Flatbed Scan sub-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
M018/M019
4-8
SM Appendix
Service Menu Fax Maintenance RX Level Sets the reception level. [-43 dBm (Default)/ -33 dBm/ -26 dBm / -16 dBm] Sets the transmission level. [0 dBm/ -1 dBm/ -2 dBm/ -3 dBm/ -4 dBm / -5 dBm/ -6 dBm/ -7 dBm/ -8 dBm/ -9 dBm / -10 dBm/ -11 dBm/ -12 dBm/ -13 dBm / -14 dBm/ -15 dBm]
Modem Settings
TX Level
Protocol Definition
This sets the number of training retries to be Training Retries repeated before automatic fallback. [1 Time/ 2 Times (Default)/ 3 Times/ 4 Times] Encoding Sets the compression method for Tx/Rx. [MMR+MR+MH (Default)/ MR+MH/ MH] Timeout for response from the called station in automatic sending mode [35 Sec/ 45 Sec/ 55 Sec (Default)/ 60 Sec/ 90 Sec/ 140 Sec] Set the time length for the T1 timer. [40 Sec (Default)/ 50 Sec] Set the time length for the T4 timer. [3 Sec (Default/ 4.5 Sec]
T1 Timer T4 Timer
SM Appendix
4-9
M018/M019
These selectors are used to improve the pass-band characteristics of analogue signals on Cable Equalizer the telephone line. [0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]
Service Menu Fax Maintenance Silence (No tone) detection time (Rx mode : FAX/ TAD Only) After the line is connected via the external telephone, the machine can detect silence (no tone) for the time length specified by this setting. [30 sec (Default)] CNG tone detection time ( RX mode : FAX / TEL, FAX / TAD Only) After the line is connected via the external telephone, the machine can detect a CNG signal for the time length specified by this setting. [5 Sec (Default)/ 10 Sec] Number of CNG cycles to be detected This setting is only effective for FAX/TAD mode. [1.5 Cycle (Default)/ 2.0 Cycle] Determines the period when tones from the line are monitored. [No Monitoring/ Up To Phase B (Default)/ All TX Phases] Pressing the Stop/Clear key can stop the current receiving operation. Received data is lost. [Not Functional (Default)/ Functional] Sets the off-hook detection threshold. [10V (Default)/ 15V/ 20V/ 25V] Sets the redial interval when Tx fails. [5 Min/ 6 Min] Sets the number of redials when Tx fails. [2 times/ 3 Times/ 4 Times/ 5 Times]
M018/M019
4-10
SM Appendix
Service Menu Fax Maintenance Overseas Comm Mode Overseas Comm Mode Settings Minimum Time Length This sets the machine to ignore a DIS signal sent from the called station once in a sending operation. [Off (Default)/ Ignore DIS Once] If this setting is set to "On", the machine detects the CNG signal after the line is connected. If it is set to "Off", the machine detects the CNG signal as long as the line is connected. [100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]
This sets the number of pulses that are generated during dialing. N: Dialing '0' generates 10 pulses --- Dialing '9' generates 9 pulses. Dial Pulse Setting Dial Pulse Type N+1: Dialing '0' generates 1 pulses --- Dialing '9' generates 10 pulses. 10-N: Dialing '0' generates 10 pulses --Dialing '9' generates 1 pulse. Tone Signal Transmission Time Length Sets the tone signal transmission time length [100 ms (Default)]
Minimum Pause Sets the minimum pause during tone dialing In Tone Dialing [100 ms (Default)/ 150 ms/ 200 ms] Attenuator For Sets the attenuator for pseudo ringback tone to the Pseudo Ring line Backtone To the [0 to 15 / 10 (Default)/ 1 dB/step] Line DTMF Level Sets the transmission level of DTMF tones. [-12 dBu / -11 dBu/ -10 dBu/ -8 dBu/ -6 dBu]
SM Appendix
4-11
M018/M019
Service Menu Fax Maintenance DTMF Delta Sets the level difference between high band frequency signals and low band frequency signals when sending DTMF tones. [2 dBu/ 3 dBu] The machine starts dialing after the specified interval without detection of a dial tone when Dial tone detection is set to "No detection". [3.5 Sec (Default)/ 7.0 Sec/ 10.5 Sec / 14.0 Sec]
This setting sets the time-out length for the 1st dial tone detection. The machine waits for a dial tone Timeout Length for the specified time and disconnects itself from the line when no dial tone is input. [10 Sec (Default)/ 15 Sec/ 20 Sec/ 30 Sec] BT Setting
DFU
DFU
BT (Busy Tone) Detection BT Frequency
[300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550 Hz/ 350-500 Hz/ 350-550 Hz/ 375-475 Hz/ 380-520 Hz]
BT Level BT Cadence
DFU DFU
[-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB] [0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/ 0.50/ 0.75]
M018/M019
4-12
SM Appendix
Service Menu Fax Maintenance The machine checks the actual data reconstruction errors and then transmits an RTN depending on the decoding error rate that is set by this setting (Number of lines containing an error per page / Total number of lines per page). [10%/ 15%]
DFU DFU
[Permitted (Default)/ Prohibited] [Permitted (Default)/ Prohibited] These selectors set the equalizer's training level to be applied if training fails due to poor line connection. [Automatic (Default)/ 4 Points/ 16 Points] Resend when a communication error occurs. [Disabled (Default)/ Not Disabled] Sets the first transmission speed choice, before fallback. [2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps / 12000 Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/ 21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/ 31200 Bps/ 33600 Bps (Default)] This setting limits the transmission speed range in V.34 mode by masking the desired symbol rate(s). [Not Used (Default)/ 3429 Sym/Sec / 3200 Sym/Sec/ 3000 Sym/Sec / 2800 Sym/Sec/ 2400 Sym/Sec]
Equalizer
Redialing
V34 Settings
First TX Speed
Symbol Rate
SM Appendix
4-13
M018/M019
Service Menu
Rev. 07/02/2009
The "Reseller Default" menu can be entered directly at power-on. If you want to enter this mode directly, try the following procedure SPC 232SF Reset Password. 1. 2. 3. 4. 5. 6. 7. 8. 9. Power OFF the unit. Power ON the unit while holding down the Copy key. Continue to hold down the Copy key until the display indicates Factory Default Execute. Release the Copy key. Press the Down Arrow, the display will change to Factory Default Execute. Press the OK key. The machine will display Executing and will perform a soft boot. When the unit returns to the ready condition, reboot by turing the Main Switch OFF and then ON. Set Language, Fax Number, Name and Country. 10. Reboot the machine.
Selecting an Item
To select the item, press the "Up" or "Down" key.
M018/M019
4-14
SM Appendix
Rev. 07/02/2009
Service Menu
Menu List
Fax Test Off-Hook Test On Hook Off Hook CED Test CNG Test ANSam Ring Tone Test Tone [0] to [9] DTMF Test Tone [*] Tone [#] Tone Stop [V34] 33600 bps [V34] 28800 bps [V17] 14400 bps [V17] 12000 bps [V17] 9600 bps Modem Test [V17] 7200 bps [V29] 9600 bps [V29] 7200 bps [V27] 4800 bps [V27] 2400 bps [V21] 300 bps Signal Stop 1100 Hz Executes the on hook test. Executes the off hook test Executes the CED test. Executes the CNG test Executes the ANSam test. Executes the ring tone test. Executes the DTMF tone 0 to 9 test. Executes the DTMF tone * test. Executes the DTMF tone # test. Executes the Stop DTMF tone test. Generates the [V34] 33600 bps signal. Generates the [V34] 28800 bps signal. Generates the [V17] 14400 bps signal. Generates the [V17] 12000 bps signal. Generates the [V17] 9600 bps signal. Generates the [V17] 7200 bps signal. Generates the [V29] 9600 bps signal. Generates the [V29] 7200 bps signal. Generates the [V27] 4800 bps signal. Generates the [V27] 2400 bps signal. Generates the [V21] 300 bps signal. Generates the Stop signal.
Appendix: SP Mode Tables M018/M019
SM Appendix
4-15