0% found this document useful (0 votes)
192 views15 pages

SPC232SF SPmode

This document provides a summary of service menus for a multifunction printer. It includes menus for maintenance, printing reports, engine settings, scan settings, and fax settings. Each menu allows adjusting various parameters such as registration, limits, compression settings, and more. The menus can be accessed via key presses and used to optimize device performance and calibration.

Uploaded by

Helder Costa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
192 views15 pages

SPC232SF SPmode

This document provides a summary of service menus for a multifunction printer. It includes menus for maintenance, printing reports, engine settings, scan settings, and fax settings. Each menu allows adjusting various parameters such as registration, limits, compression settings, and more. The menus can be accessed via key presses and used to optimize device performance and calibration.

Uploaded by

Helder Costa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Rev.

11/17/2011

Service Menu

4. APPENDIX: SP MODE TABLES


4.1 SERVICE MENU
4.1.1 OVERVIEW
This model has several service menus. Each service menu has several adjustment items. This section explains how to enter each service menu and what you can do in each service menu. Each menu is classified into two "Modes" depending on how you enter the service menus. "Menu Mode" can be executed by depressing the following key sequence while in ready condition: Clear/Stop, 1, 0, 7 and Color Start. (Press and hold each key till a beep is heard.) has been replaced. Please contact your Technical Service Manager for details. Each menu is classified as follows: Menu Mode Maintenance Mode Menu Special Mode Fax Service Test Menu Function This is a menu for maintenance and service. This mode is used to input the serial number. This is a menu for checking the fax mode.
Appendix: SP Mode Tables

"Special Mode" is needed to input the serial number after the Engine Board EEPROM

4.1.2 MAINTENANCE MODE MENU


Selecting an Item
To select an item, press the "Up" or "Down" key.

Going into the Next Level/ Returning to the Previous Level


To go into the next level of an item, select an item then press the "OK" key. To return to the previous level of an item, press the "Return" key.

Exiting the Maintenance Mode Menu


To exit the maintenance mode menu, press the "Clear/Stop" or "Return" key until the "Ready" display appears.

SM Appendix

4-1

M018/M019

Service Menu
Menu List

Display Info Model Name CTL FW Ver. FW Ver. FAX FW Ver. MCTL FW Ver. PDL FW Ver. Printer Counter Displays the Model Name, Depends on Engine Firmware Settings Displays the Firmware Version Displays the PDL Firmware Version. Displays the Engine Firmware Version Displays the PDL Firmware Version. Displays the following counters of the printer engine. Total Page/ Color Image/ Black Image Displays the sum total of scanner counters for each mode. Total Page/ Black Page/ Color Page / ADF Used Displays the number of paper jams at each location. Total/ ADF/ Printer Output Bin/ Internal/ Tray1 / Tray2/ Duplex Coverage 1: [0 to 100 / 5 / 1/step] Coverage 2: [0 to 100 / 20 / 1/step] Changes the thresholds for each coverage counter.

Scanner Counter Counter Jam Counter

Coverage 1/ Coverage 2

M018/M019

4-2

SM Appendix

Service Menu Print Reports G3 Protocol dump list G3 protocol dump of the latest communication is printed. Off (Default)/ Error/ On

Engine Maintenance Determines the maximum amount of ink/toner you can use in any area of your text. This is where you are controlling exactly how much ink will be used during printing. [200 to 400 / 250 (Default)/ 10/step] Setting 0: Off Determines the maximum amount of ink/toner you can use in any area of your graphic. This is where you are controlling exactly how much ink will be used during printing. [200 to 400 / 250 (Default)/ 10/step] Setting 0: Off Determines the maximum amount of ink/toner you can use in any area of your image. This is where you are controlling exactly how much ink will be used during printing. [200 to 400 / 250 (Default)/ 10/step] Setting 0: Off

Text

Toner Limit

Graphic

Image

PNP Name

NA Model: RICOH/ 'nul' EU Model: RICOH/ NRG/ LANIER ASIA Model: RICOH/ LANIER China Model: RICOH

SM Appendix

4-3

M018/M019

Appendix: SP Mode Tables

Service Menu Engine Maintenance Destination Sets the destination and updates the engine setting. JPN/ NA (Default)/ EU/ ASIA/ China 2nd Transfer Front 2nd Transfer Back 2nd Transfer Fuser Temp. Fuser Temperature Adjusts the transfer roller current, based on the default value. [-15 to 15 / 0 (Default) / 1 PA/step] Adjusts the transfer roller current, based on the default value. [-15 to 15 / 0 (Default) / 1 PA/step] Adjusts the temperature of the fusing unit, based on the default value. [-30 to 0 / 0 (Default) / 2C/step] Plain Paper (90-105 g/m2)/ Plain Paper/ Thick Paper (1405-110 g/m2)/ Thin Paper (60-75 g/2)/ Thick Paper (Post Card)/ Envelop/ Cardstock/ Bond paper/ Label Paper/ Prepunched/ Preprinted/ Letterhead/ Color/ Recycled Adjusts the horizontal registration for tray 1. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step] Adjusts the vertical registration for tray 1. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.24 mm/step] Adjusts the horizontal registration for tray 2. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step]

Media Type

Horiz. Tray1

Registration

Vert.Tray1

Horiz.Tray2

M018/M019

4-4

SM Appendix

Service Menu Engine Maintenance Vert.Tray2 Adjusts the vertical registration for tray 2. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.3 mm/step] Adjusts the horizontal registration for the bypass tray. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step] Adjusts the vertical registration for the bypass tray. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.3 mm/step] Adjusts the horizontal registration for the back side in duplex mode. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 4 mm/step] Adjusts the vertical registration for the back side in duplex mode. If the machine settings are reset to the factory defaults, this value does not change. [-15 to 15 / 0 (Default) / 0.3 mm/step]

Horiz.Bypass

Registration Horiz.Dup.Back

Vert.Dup.Back Reset Count Clear Count Replace Fuser

Resets counters to factory defaults. Clears the Scanner and Jam Counters. Resets the maintenance counter for the fusing unit. This item appears only when the fusing unit life is almost expired or has expired.

SM Appendix

4-5

M018/M019

Appendix: SP Mode Tables

Vert.Bypass

Service Menu Engine Maintenance Init Engine EEPROM This clears all counters except "Full Color" and "Black and White" in the total counter. When you execute "Init Engine EEPROM", the engine EEPROM is initialized. Turn the machine power off/on after you change this setting. Displays only 1: MF2b 2: M019 Displays the current model in a dropdown list. Do not change this setting (Designed for Factory Use). 00* 7F Displays the current brand ID number. Do not change this setting (Designed for Factory Use). Input 160 bytes setting. Character: alphanumeric "0-9", "a-f", "A-F", only valid data can be input. Input length: 160 bytes

Model

Brand ID

LSU Adjustment

When you execute "Trans. Belt Adjust", the transfer belt adjustment is Trans. Belt Adjust done. This calibrates the motor speed to match the length of the new transfer belt. Fuser SC Detect On/Off* Color Registration If On, the engine detects SC559. If Off, the engine does not detect "Fusing SC Reset".

The engine will do color registration and density tuning automatically. The machine will warm up automatically after this setting is changed.

Reset Transfer Resets the transfer unit life counter. Unit Life Counter

M018/M019

4-6

SM Appendix

Service Menu Engine Maintenance Fuser SC Reset Special Mode This button is for resetting an SC related with the fusing errors.

For future use, this mode is not used in this mode.


[0 to 7F] Write command: EEC34 (0xA2, 0x00 to 7F) Read command: EEC34 (0xE2, 0x01)

SM Appendix

4-7

M018/M019

Appendix: SP Mode Tables

Service Menu Scan Maintenance Mono Compression Setting Sets the monochrome compression type for scanning. MH (Default)/ MR/ MMR ADF Main Reg. ADF Sub Reg. Regist Adjust Flatbed Main Reg. Flatbed Sub Reg. ADF Main Reg. ADF Sub Reg. Size Adjust Flatbed Main Reg. Flatbed Sub Reg. Adjusts the ADF Scan main-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the ADF Scan sub-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the Flatbed Scan main-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the Flatbed Scan sub-scan registration. [-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step] Adjusts the ADF Scan main-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step] Adjusts the ADF Scan sub-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step] Adjusts the Flatbed Scan main-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step] Adjusts the Flatbed Scan sub-scan magnification. [-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]

M018/M019

4-8

SM Appendix

Service Menu Fax Maintenance RX Level Sets the reception level. [-43 dBm (Default)/ -33 dBm/ -26 dBm / -16 dBm] Sets the transmission level. [0 dBm/ -1 dBm/ -2 dBm/ -3 dBm/ -4 dBm / -5 dBm/ -6 dBm/ -7 dBm/ -8 dBm/ -9 dBm / -10 dBm/ -11 dBm/ -12 dBm/ -13 dBm / -14 dBm/ -15 dBm]

Modem Settings

TX Level

Protocol Definition

This sets the number of training retries to be Training Retries repeated before automatic fallback. [1 Time/ 2 Times (Default)/ 3 Times/ 4 Times] Encoding Sets the compression method for Tx/Rx. [MMR+MR+MH (Default)/ MR+MH/ MH] Timeout for response from the called station in automatic sending mode [35 Sec/ 45 Sec/ 55 Sec (Default)/ 60 Sec/ 90 Sec/ 140 Sec] Set the time length for the T1 timer. [40 Sec (Default)/ 50 Sec] Set the time length for the T4 timer. [3 Sec (Default/ 4.5 Sec]

T0 Timer Protocol Definition Timer

T1 Timer T4 Timer

SM Appendix

4-9

M018/M019

Appendix: SP Mode Tables

These selectors are used to improve the pass-band characteristics of analogue signals on Cable Equalizer the telephone line. [0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]

Service Menu Fax Maintenance Silence (No tone) detection time (Rx mode : FAX/ TAD Only) After the line is connected via the external telephone, the machine can detect silence (no tone) for the time length specified by this setting. [30 sec (Default)] CNG tone detection time ( RX mode : FAX / TEL, FAX / TAD Only) After the line is connected via the external telephone, the machine can detect a CNG signal for the time length specified by this setting. [5 Sec (Default)/ 10 Sec] Number of CNG cycles to be detected This setting is only effective for FAX/TAD mode. [1.5 Cycle (Default)/ 2.0 Cycle] Determines the period when tones from the line are monitored. [No Monitoring/ Up To Phase B (Default)/ All TX Phases] Pressing the Stop/Clear key can stop the current receiving operation. Received data is lost. [Not Functional (Default)/ Functional] Sets the off-hook detection threshold. [10V (Default)/ 15V/ 20V/ 25V] Sets the redial interval when Tx fails. [5 Min/ 6 Min] Sets the number of redials when Tx fails. [2 times/ 3 Times/ 4 Times/ 5 Times]

Silence Detection Time

CNG Tone Detection Time

RX Settings CNG Cycles

Tone Sound Monitoring

Stop/Clear key Off-Hook Level Redial Interval TX Settings Redialings

M018/M019

4-10

SM Appendix

Service Menu Fax Maintenance Overseas Comm Mode Overseas Comm Mode Settings Minimum Time Length This sets the machine to ignore a DIS signal sent from the called station once in a sending operation. [Off (Default)/ Ignore DIS Once] If this setting is set to "On", the machine detects the CNG signal after the line is connected. If it is set to "Off", the machine detects the CNG signal as long as the line is connected. [100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]

This sets the number of pulses that are generated during dialing. N: Dialing '0' generates 10 pulses --- Dialing '9' generates 9 pulses. Dial Pulse Setting Dial Pulse Type N+1: Dialing '0' generates 1 pulses --- Dialing '9' generates 10 pulses. 10-N: Dialing '0' generates 10 pulses --Dialing '9' generates 1 pulse. Tone Signal Transmission Time Length Sets the tone signal transmission time length [100 ms (Default)]

Tone Signal Settings

Minimum Pause Sets the minimum pause during tone dialing In Tone Dialing [100 ms (Default)/ 150 ms/ 200 ms] Attenuator For Sets the attenuator for pseudo ringback tone to the Pseudo Ring line Backtone To the [0 to 15 / 10 (Default)/ 1 dB/step] Line DTMF Level Sets the transmission level of DTMF tones. [-12 dBu / -11 dBu/ -10 dBu/ -8 dBu/ -6 dBu]

SM Appendix

4-11

M018/M019

Appendix: SP Mode Tables

Service Menu Fax Maintenance DTMF Delta Sets the level difference between high band frequency signals and low band frequency signals when sending DTMF tones. [2 dBu/ 3 dBu] The machine starts dialing after the specified interval without detection of a dial tone when Dial tone detection is set to "No detection". [3.5 Sec (Default)/ 7.0 Sec/ 10.5 Sec / 14.0 Sec]

Wait Time 1Dial Tone Detection

This setting sets the time-out length for the 1st dial tone detection. The machine waits for a dial tone Timeout Length for the specified time and disconnects itself from the line when no dial tone is input. [10 Sec (Default)/ 15 Sec/ 20 Sec/ 30 Sec] BT Setting

DFU

[Off/ On] BT: Busy tone

DFU
BT (Busy Tone) Detection BT Frequency

[300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550 Hz/ 350-500 Hz/ 350-550 Hz/ 375-475 Hz/ 380-520 Hz]

BT Level BT Cadence

DFU DFU

[-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB] [0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/ 0.50/ 0.75]

M018/M019

4-12

SM Appendix

Service Menu Fax Maintenance The machine checks the actual data reconstruction errors and then transmits an RTN depending on the decoding error rate that is set by this setting (Number of lines containing an error per page / Total number of lines per page). [10%/ 15%]

RTN Rate Comm Settings V34 Modem V17 Modem

DFU DFU

[Permitted (Default)/ Prohibited] [Permitted (Default)/ Prohibited] These selectors set the equalizer's training level to be applied if training fails due to poor line connection. [Automatic (Default)/ 4 Points/ 16 Points] Resend when a communication error occurs. [Disabled (Default)/ Not Disabled] Sets the first transmission speed choice, before fallback. [2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps / 12000 Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/ 21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/ 31200 Bps/ 33600 Bps (Default)] This setting limits the transmission speed range in V.34 mode by masking the desired symbol rate(s). [Not Used (Default)/ 3429 Sym/Sec / 3200 Sym/Sec/ 3000 Sym/Sec / 2800 Sym/Sec/ 2400 Sym/Sec]

Equalizer

Redialing

V34 Settings

First TX Speed

Symbol Rate

SM Appendix

4-13

M018/M019

Appendix: SP Mode Tables

Service Menu

Rev. 07/02/2009

The "Reseller Default" menu can be entered directly at power-on. If you want to enter this mode directly, try the following procedure SPC 232SF Reset Password. 1. 2. 3. 4. 5. 6. 7. 8. 9. Power OFF the unit. Power ON the unit while holding down the Copy key. Continue to hold down the Copy key until the display indicates Factory Default Execute. Release the Copy key. Press the Down Arrow, the display will change to Factory Default Execute. Press the OK key. The machine will display Executing and will perform a soft boot. When the unit returns to the ready condition, reboot by turing the Main Switch OFF and then ON. Set Language, Fax Number, Name and Country. 10. Reboot the machine.

4.1.3 FAX SERVICE TEST MENU


Entering the Fax Service Test Menu
Turn ON the machine while pressing the "Fax" key.

Selecting an Item
To select the item, press the "Up" or "Down" key.

Going into the Next Level/ Returning to the Previous Level


To go into the next level of an item, select an item then press the "OK" key. To return to the previous level of an item, press the "Return" key.

Exiting the Maintenance Mode Menu


To exit the maintenance mode menu, press the "Clear/Stop" or "Return" key until the "Ready" display appears.

M018/M019

4-14

SM Appendix

Rev. 07/02/2009

Service Menu

Menu List
Fax Test Off-Hook Test On Hook Off Hook CED Test CNG Test ANSam Ring Tone Test Tone [0] to [9] DTMF Test Tone [*] Tone [#] Tone Stop [V34] 33600 bps [V34] 28800 bps [V17] 14400 bps [V17] 12000 bps [V17] 9600 bps Modem Test [V17] 7200 bps [V29] 9600 bps [V29] 7200 bps [V27] 4800 bps [V27] 2400 bps [V21] 300 bps Signal Stop 1100 Hz Executes the on hook test. Executes the off hook test Executes the CED test. Executes the CNG test Executes the ANSam test. Executes the ring tone test. Executes the DTMF tone 0 to 9 test. Executes the DTMF tone * test. Executes the DTMF tone # test. Executes the Stop DTMF tone test. Generates the [V34] 33600 bps signal. Generates the [V34] 28800 bps signal. Generates the [V17] 14400 bps signal. Generates the [V17] 12000 bps signal. Generates the [V17] 9600 bps signal. Generates the [V17] 7200 bps signal. Generates the [V29] 9600 bps signal. Generates the [V29] 7200 bps signal. Generates the [V27] 4800 bps signal. Generates the [V27] 2400 bps signal. Generates the [V21] 300 bps signal. Generates the Stop signal.
Appendix: SP Mode Tables M018/M019