Product Data Sheet Edition 3.28.

2012 SikaGrout 328

SikaGrout 328
Description

High performance, precision, grout with extended working time


SikaGrout 328 is a non-shrink, cementitious precision grout powered by ViscoCrete technology. This grout provides extended working time and exceptional physical performance at fluid consistency. SikaGrout 328 is non metallic and contains no chlorides. A structural, precision grout, SikaGrout 328 can be placed from fluid to dry pack over a temperature range of 40-95F. SikaGrout 328 meets the ASTM-C 1107 (Grade B & C) and Corps of Engineers Specification CRD-C621. Where to Use n Where exceptional one day and ultimate compressive strengths are required. n Applications requiring a pumpable grout. n Non-shrink grouting of machinery and equipment, base plates sole plates, precast panels, beams, columns and curtainwalls. n Applications where a non-shrink grout is needed for maximum effective bearing area to transfer optimum load. n For underwater application in conjunction with Sikament 100SC. Consult Technical Ser- vice for dosage information. Independent test data is available however on site testing is recommended to confirm performance under actual field conditions. n For grouting rebar, bolts, dowels and pins, etc. Advantages

Construction

fluidity with one material. 10,000 psi in dry pack consistency. n Outstanding performance in fluid state. n Extended working time. n Excellent fluidity - sufficient time for placement. n Contains premium quality quartz aggregate. n Hardens free of segregation.
n Reaches

n Multiple

Typical Data (Material and curing conditions @ 73F (23C) and 50% R.H.)
REsuLts MaY dIFFEr BasEd upON statIstICaL VarIatIONs dEpENdING upON MIXING MEtHOds aNd EQuIpMENt, tEMpEraturE, appLICatION MEtHOds, tEst MEtHOds, aCtuaL sItE CONdItIONs aNd CurING CONdItIONs.

Shelf Life Storage Conditions Color Flow Conditions

One year in original, unopened bags. Store dry at 40-95F (4-35C). Recommend conditioning material to 65-75F before using. Concrete gray Dry Pack (10-25%) 5.5 -6.0 pts. <15mins < 2 hrs Plastic Flowable1 (100-125%) (124-145%) 6.5 -7.0 pts. 7.0 -7.5 pts. > 2 hr. > 3 hr. < 6 hr. < 7 hr. 4,500 6,500 7,000 8,200 4,000 6,000 6,700 8,000 Fluid 2 (20-60 sec) 8.0 -8.5 pts. > 4 hr. < 8 hr. 3,500 5,500 6,500 7,500 350 400 650 1,100 1,200 1,300

Typical Water Requirements: Set Time (ASTM C-191):

Initial Final

Compressive Strength, psi ASTM-C-109 1 day 5,000 3 day 8,000 14 day 9,200 10,000 28 day

Splitting Tensile, psi (ASTM C-496) 3 day 7 day 28 day

Flexural Strength, psi (ASTM C-78) 3 day 7 day 28 day

Bond Strength, psi (ASTM C-882 modified): Hardened concrete to plastic grout 3 day
1

950 1750 2000

7 day 28 day 300 Cycles RDF 99%

Freeze Thaw Cycles Procedures - (ASTM - C-666)


CRD C-227: 100-124% (plastic), 124-145% (flowable) 2 CRD C-611: 10-30 sec efflux time.

n Non-metallic, n Meets

Coverage Packaging

How to Use
Surface Preparation

will not stain or rust. CRD C-621 & ASTM C-1107 (Grade C). n Shows positive expansion. n SikaGrout 328 is USDA-approved. Approximately 0.44 cu. ft./bag at high flow. Multi-wall bags; 40 bags/pallet, 50 lbs. per bag.
Remove all dirt, oil, grease, and other bond-inhibiting materials by mechanical means. Anchor bolts to be grouted must be de-greased with suitable solvent. Concrete must be sound and roughened to promote mechanical adhesion. Prior to pouring, surface should be brought to a SSD (saturated surfacedry) condition. For pourable grout, construct forms to retain grout without leakage. Forms should be lined or coated with bond-breaker for easy removal. Forms should be sufficiently high to accommodate head of grout. Where grout-tight form is difficult to achieve, use SikaGrout 328 in dry pack consistency. Mechanically mix with a low speed drill (400-600 rpm) for at least 5 minutes using a Sika mixing paddle or a jiffy paddle. SikaGrout 328 can be mixed in an appropriately sized mortar mixer. Mixing should continue until a homogenous mixture is achieved. Product Extension: For deeper applications, SikaGrout 328 (plastic and flowable consistencies only) may be extended with 25 lbs. of 3/8 pea gravel. The aggregate must be non-reactive (Reference ASTM C1260, C227 and C289), clean, well-graded, saturated surface dry, have low absorption and high density, and comply with ASTM C33 size number 8 per Table 2. Add the pea gravel after the water and SikaGrout 328. Make sure all forming, mixing, placing, and clean-up materials are on hand. Add appropriate quantity of clean water to achieve desired flow. Add bag of powder to mixing vessel. Mix to a uniform consistency, minimum of 5 minutes. Ambient and material temperature should be as close as possible to 70F. If higher, use cold water; if colder, use warm water. Within 60 minutes after mixing, place grout into forms in normal manner to avoid air entrapment. Vibrate, pump, or ram grout as necessary to achieve flow or compaction. SikaGrout 328 must be con fined leaving minimum exposed surface. After grout has achieved final set, remove forms, trim or shape exposed grout shoulders to designed profile. SikaGrout 328 is an excellent grout for pumping, even at high flow. For pump recommendations, contact Technical Service. Wet cure for a minimum of 3 days or apply a curing compound which complies with ASTM C-309 on exposed surfaces. ambient and substrate temperature 45F and rising at time of application. application thickness: 1/2 in. n For application thicknesses of 6 inches or greater, consult Sikas Technical Service Department. n Do not use as a patching or overlay mortar or in unconfined areas. n Material must be placed within 60 minutes of mixing. n As with all cement based materials, avoid contact with aluminum to prevent adverse chemical reaction and possible product failure. Insulate potential areas of contact by coating aluminum bars, rails, posts etc. with an appropriate epoxy such as Sikadur 32 Hi-Mod.
n Minimum n Minimum

Forming

Mixing

Construction

Mixing Procedure

Application

Limitations
Irritant

CautION
First Aid

Contains Portland Cement (CAS 65997-15-1), Silica Quartz (CAS 14808-60-7). May cause eye/skin/ respiratory irritation. May cause delayed lung damage (silicosis). May be harmful if swallowed. This product contains an ingredient known to the state of California to cause cancer. Eyes - Hold lids apart and immediately flush thoroughly with tepid water for at least 15 minutes. Skin - Wash thoroughly with soap and water. Inhalation - Remove person to fresh air. If not breathing, give artificial respiration. Ingestion - Do not induce vomiting. In all cases, if symptoms persist, contact a physician immediately. Wear protective equipment (chemical resistant gloves/safety glasses/clothing) to prevent contact with skin and eyes. Keep container closed in a cool dry place. Wash skin thoroughly with soap and water after use. Use with adequate general and local exhaust ventilation. In the absence of adequate ventilation, use a properly fitted NIOSH respirator. Remove contaminated clothing. Launder before reuse. Avoid direct contact with eyes and skin. Wearing chemical resistant gloves/goggles/clothing, collect spill. Ventilate area. In the absence of adequate ventilation, use a properly fitted NIOSH respirator. Sweep up spill and place in closed container. Dispose of in accordance with applicable local, state and federal environmental regulations.

Handling and Storage

Clean Up

Construction
All information provided by Sika Corporation (Sika) concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sikas current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sikas instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sikas control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at www.sikausa.com or by calling 800-933-7452. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the products most current Technical Data Sheet, product label and Material Safety Data Sheet which are available online at www.sikausa.com or by calling Sika's Technical Service Department at 800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. LIMITED WARRANTY: Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyers sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OtHEr warraNtIEs EXprEss Or IMpLIEd sHaLL appLY INCLudING aNY warraNtY OF MErCHaNtaBILItY Or FItNEss FOr a partICuLar purpOsE. SIkasHaLLNOt BE LIaBLE uNdEraNYLEGaLtHEOrYFOr spECIaLOr CONsEQuENtIaLdaMaGEs. SIKASHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
KEEP CONTAINER TIGHTLY CLOSED KEEP OUT OF REACH OF CHILDREN NOT FOR INTERNAL CONSUMPTION FOR INDUSTRIAL USE ONLY

Visit our website at www.sikausa.com 1-800-933-SIKA NATIONWIDE Regional Information and Sales Centers. For the location of your nearest Sika sales office, contact your regional center. Sika Corporation Sika Canada Inc. Sika Mexicana S.A. de C.V. 201 Polito Avenue 601 Delmar Avenue Carretera Libre Celaya Km. 8.5 Lyndhurst, NJ 07071 Pointe Claire Fracc. Industrial Balvanera Phone: 800-933-7452 Quebec H9R 4A9 Corregidora, Queretaro ISO 9001 Fax: 201-933-6225 Phone: 514-697-2610 C.P. 76920 RC 14001 Fax: 514-694-2792 Phone: 52 442 2385800 Sika and SikaGrout are registered trademarks. Fax: 52 442 2250537 Printed in Canada.