Fire Resistant M17/74 - RG 213 (RG 213/U) Coaxial Cables

This document summarizes the specifications of Fireflex fire resistant coaxial cables manufactured by Caledonian. The cables are designed for CCTV, security, and fire alarm applications requiring continued functionality during a fire. They have a zero halogen, low smoke construction and meet various international fire standards. The cable construction uses a plain copper conductor, LDPE insulation, copper braid screen, mica glass tape fire barrier, and LSZH thermoplastic sheath.

Uploaded by

rose chen
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
205 views3 pages

Fire Resistant M17/74 - RG 213 (RG 213/U) Coaxial Cables

This document summarizes the specifications of Fireflex fire resistant coaxial cables manufactured by Caledonian. The cables are designed for CCTV, security, and fire alarm applications requiring continued functionality during a fire. They have a zero halogen, low smoke construction and meet various international fire standards. The cable construction uses a plain copper conductor, LDPE insulation, copper braid screen, mica glass tape fire barrier, and LSZH thermoplastic sheath.

Uploaded by

rose chen
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

FIREFLEX Fire Resistant Coaxial Cables

www.caledonian-tech.net [email protected]

Caledonian

Fire Resistant M17/74 - RG 213 (RG 213/U) Coaxial cables

Plain Copper Wire Braid Screen PE Insulation Plain Copper Mica Glass Tape PVC Sheath

APPLICATION
The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, thiscable is ideal for use in public, commercial and industrial environments.

STANDARDS
Basic design adapted to MIL-C-17

FIRE PERFORMANCE
Circuit Integrity Circuit Integrity with mechanical shock Circuit Integrity with mechanical shock & water spray System Circuit Integrity Flame Retardance (Single Vertical Wire Test) Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) Halogen Free No Corrosive Gas Emission Minimum Smoke Emission No Toxic gases IEC 60331-23; BS 6387; DIN VDE 0472-814(FE180); BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) EN 50200(PH60); CEI 20-36/4-0 EN 50200 annex E DIN 4102-12, E30 depending on lay system EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1; BS 6425-1* IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2* IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

[email protected]

ADDISON

ADDISON
CABLE CONSTRUCTION
Conductors: Plain copper conductor according to IEC(EN) 60228 class 2. Insulation: LDPE compound. Overall Screen: Plain copper wire braid Fire Barrier: Mica glass tape. Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1(Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

PHYsical AND THERMAL PROPERTIES


Temperature range during operation (fixed state): -30C - +70C Temperature range during installation (mobile state): -5C - +60C Minimum bending radius: 8 x Overall Diameter

Electrical Properties
Impedance Nominal capacitance Velocity of propagation Shield coverage Insulation resistance Inner conductor resistance Outer conductor resistance Test/Operatig Voltage(max) Operating temperature range Copper Weight Cable weight (approx.) Screening effectiveness 503 Ohm 100 pF/m 66% 95% >2000 Mohm.Km 6.0 Ohm/Km 4.5 Ohm/Km 10KV/5KV -30 C - +70 C 76.9 Kg/Km 163 Kg/Km 100-900 MHz >55dB

Attenuation
Frequency(MHz)
50 100 200 400 500 600 860 1000

Attenuation (dB/100 m)
4.5 6.7 9.9 14.3 16.1 17.8 22.1 24.3

Attenuation (dB/100ft)
1.37 2.04 3.02 4.36 4.91 5.43 6.74 7.41

10

Caledonian

www.caledonian-tech.net

FIREFLEX Fire Resistant Coaxial Cables


www.caledonian-tech.net [email protected]

Caledonian

Return Loss
Frequency(MHz) 30-300 MHz 300-600 MHz 600-900 MHz Return Loss (dB) >31dB >28dB >27dB

CONSTRUCTION PARAMETERS
Cable Code Conductor Diameter mm FFX-RG213/U
300/500V

Nominal Insulation Diameter mm 7.25 0.10 m


E

Copper Wire Braid Coverage % 95%

Nominal Overall Diameter mm 10.9 0.18

Approx. Weight kg/km 198

7/0.75

N
MIL-C-17 Standard
Low Corrosivity IEC60754-2 EN50267-2-2/3 NF C 32-074

Rated Voltage

Flame Retardancy Reduced Fire Propagation Circuit Integrity NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC 60331/BS 6387 NF C32-070-2.3(CR1) IEC60332-3-24/EN50266-2-4 IEC60332-1-2/EN50265-2-1

Zero

Low Toxicity NES 02-713/NF C 20-454

Low Smoke Emission IEC 61034-1&2 EN 50268-1&2/NF C32-073

Halogen Free IEC60754-1 EN50267-2-1

Functional Integrity DIN 4102-12