HYD. Pump
HYD. Pump
HYD. Pump
Pneumatics
Service Automation
Mobile Hydraulics
open circuit
Size 28...140 Series 31 Nominal pressure 280 bar Peak pressure 350 bar
Contents
Ordering Code / Standard Program 2, 3 Fluid, Mechanical Displacement Limiter, High-Speed-Version 4 Technical Data 5 Installation Notes 6 Noise Characteristics 7 Drive Power and Flow 8, 9 Unit Dimensions, Size 28 10 Unit Dimensions, Size 45 11 Unit Dimensions, Size 71 12 Unit Dimensions, Size 100 13 Unit Dimensions, Size 140 14 Two-position Adjustment Direct Control DG 15 Pressure Control DR 16, 17 Pressure Control, Remote Controlled DRG 18, 19 Pressure / Flow Control DFR 20, 21 Pressure / Flow / Power Control DFLR 22, 23 Flow Control, Pilot Pressure-dependent FHD 24, 25 Through Drives 26 Unit Dimensions Combination Pumps 27 Unit Dimensions Through Drives KB2, K51, KB3 und K25 28, 29 Unit Dimensions Through Drives KB4, K26, KB5 und K27 30, 31 Unit Dimensions Through Drives KB6, K37, KB7 und K59 32, 33 Unit Dimensions Through Drives K01, K52, K02 und K68 34, 35 Unit Dimensions Through Drives K04, K07, K24 und K17 36, 37 Unit Dimensions Through Drive K57 38 Preferred Types 39
Features
Variable displacement axial piston pump of swashplate design for hydrostatic open circuit systems Flow is proportional to drive speed and displacement. It can be infinitely varied by adjustment of the swashplate. ISO mounting flange Flange connections to SAE metric 2 case drain ports Good suction characteristics Permissible continous pressure 280 bar Low noise level Long service life Axial and radial loading of drive shaft possible High power-weight ratio Wide range of controls Short response times Through drive option for multi-circuit system Further information: Variable Displacement Pump A10VSO Size 18 RE 92 712
2/40
A10VSO | RE 92 711/03.00
28...100 G G
140 G G G
E H A10VS
45 45
G G G G G G G G G G
G G G G G G G
G G
DG DR DRG DFR DFR1 DFLR FHD FE1** ED see RE 92 707 (in preparation)
G G G G G G
without orifice in X-line Pressure/flow/power control Flow control , pilot pressure dependent with pressure control Flow control, electronic Pressure/flow control, electronic Elektro-hydraulic pressure control ** For further control information see RE 30 022 Series
G DFE1**
Seals NBR nitril-caoutchouc to DIN ISO 1629 (shaft seal in FKM) FKM fluor-caoutchouc to DIN ISO 1629 Shaft end Parallel with key DIN 6885 Splined shaft SAE Splined shaft SAE (higher through drive torque) 28
G
P V 45
G
71
G
100
G
140
G
7/8" 7/8"
1" 1"
P S R
* Project note for size 71 Pressure port B consists of a high pressure combination port SAE 11/4" standard pressure range, 3000 psi, for pressures up to 250 bar SAE 1" standard pressure range, 5000 psi, for pressures in excess of 250 bar (see page 12). For new applications high pressure port SAE 1" must be used.
G = available
= in preparation
= not available
RE 92 711/03.00 | A10VSO
3/40
A10VS O
Hydraulic Fluid Axial Piston Unit Type of operation Size Control device Series Direction of rotation Seals Shaft end Mounting flange ISO 2-hole ISO 4-hole Service line connections Pressure port B SAE ports at opposite sides Suction port S Metric fixing thread Through drives without through drive with through drive to accept an axial piston pump, a gear pump or a radial piston pump Mounting flange shaft / coupling for mounting of: ISO 80, 2-hole splined shaft 3/4" 19-4 (SAE A-B) A10VSO 10, 18 (shaft S or R) ISO 80, 2-hole keyed shaft 18 A10VSO 18 ISO 100, 2-hole splined shaft 7/8" 22-4 (SAE B) A10VSO 28 (shaft S or R) ISO 100, 2-hole keyed shaft 22 A10VSO 28 ISO 100, 2-hole splined shaft 1" 25-4 (SAE B-B) A10VSO 45 (shaft S or R) ISO 100, 2-hole keyed shaft 25 A10VSO 45 ISO 125, 2-hole splined shaft 1 1/4" 32-4 (SAE C) A10VSO 71 (shaft S or R) ISO 125, 2-hole keyed shaft 32 A10VSO 71 ISO 125, 2-hole splined shaft 1 1/2" 38-4 (SAE C-C) A10VSO 100 (shaft S) ISO 125, 2-hole keyed shaft 40 A10VSO 100 ISO 180, 4-hole splined shaft 1 3/4" 44-4 (SAE D) A10VSO 140 (shaft S) ISO 180, 4-hole keyed shaft 45 A10VSO 140 82-2(SAE A, 2-hole) splined shaft 5/8" 16-4 (SAE A) 1PF2G2, PGF2 82-2(SAE A, 2-hole) splined shaft 3/4" 19-4 (SAE A-B) A10VSO 10, 18 (shaft S) 101-2(SAE B, 2-hole) splined shaft 7/8" 22-4 (SAE B) 1PF2G3 101-2 (SAE B) splined shaft 22-4 (SAE B) A10VO 28 (shaft S), PGF3 101-2(SAE B) splined shaft 25-4 (SAE B-B) A10VO 45 (shaft S), PGH4 127-2 (SAE C) splined shaft 32-4 (SAE C) A10VO 71 (shaft S) 127-2 (SAE C) splined shaft 38-4 (SAE C-C) A10VO 100 (shaft S), PGH5 152-4 (SAE D) splined shaft 44-4 (SAE D) A10VO 140 (shaft S) 63, metr. 4-hole keyed shaft 25 R4
* Not for new applications, only permissible with reduced through drive torque (see page 26)
/ 31
12
28
G
45
G
71 100 140
G G
A B
12 28
G
45
G
71 100 140
G G G
N00
G G G G G G G G G G
G G
G G G G G G G G G G G
G G G G G G G G G G G G G G G G G
G G G G G G G G G G G G G G G G
G G G G G G G G G
G G G
G G G
KB2 K51* KB3 K25* KB4 K26* KB5 K27* KB6 K37* KB7 K59* K01 K52 K02 K68 K04 K07 K24 K17 K57
Combination pumps 1. If a second Brueninghaus pump is to be fitted at factory then the two model codes must be linked with a "+" sign. Model code 1st pump + Model code 2nd pump. Ordering example: A10VSO 100DR/31R-PPA12KB5 + A10VSO 71DFR/31R-PSA12N00 2. If a gear or radial piston pump is to be fitted at factory please consult us.
4/40
A10VSO | RE 92 711/03.00
Notes on the selection of the hydraulic fluid In order to select the correct fluid, it is necessary to know the operating temperature in the tank (open loop) in relation to the ambient temperature. The hydraulic fluid should be selected so that within the operating temperature range, the operating viscosity lies within the optimum range (opt) (see shaded section of the selection diagram). We recommend that the higher viscosity range should be chosen in each case. Example: At an ambient temperature of X C the operating temperature is 60 C. Within the operating viscosity range (opt; shaded area), this corresponds to viscosity ranges VG 46 or VG 68; VG 68 should be selected. Important: The leakage oil (case drain oil) temperature is influenced by pressure and pump speed and is always higher than the tank temperature. However, at no point in the circuit may the temperature exceed 90 C. If it is not possible to comply with the above conditions because of extreme operating parameters or high ambient temperatures please consult us. Filtration The finer the filtration the better the cleanliness of the pressure fluid and the longer the life of the axial piston unit. To ensure the functioning of the axial piston unit a minimum cleanliness level of: 9 to NAS 1638 18/15 to ISO/DIS 4406 is necessary. If above mentioned grades cannot be maintained please consult supplier.
High-speed-version
The size 140 is available in an optional high speed version. This version allows higher drive speeds at max. displacement (higher output flow) without affecting outside dimensions, see table on page 5.
VG VG VG VG
viscosity (mm2/s)
200 100 80 60 40
0 10 VG 8 6
20 15 10 - 25 - 10 10 30 50 70
opt
16
22
32
46
36
tmin = -25 C
tmax = +90 C
t ( C)
Mechanical displacement limiter is possible on the nonthroughdrive model, N00 series but not for the model with throughdrive. Exception: with FE1-, FE1D- and DFE1 control a max. displacement screw is not possible at all. Vg max : for sizes 28 to 140 Setting range Vg max to 50% Vg max stepless Vg min : for sizes 100 and 140 Setting range Vg min to 50% Vg max stepless
RE 92 711/03.00 | A10VSO
5/40
Technical Data
(valid for operation on mineral oil; for HF-fluids see RE 90223 and environmentally acceptable hydraulic fluids see RE 90221) Operating pressure range - inlet Absolute pressure at port S pabs min _____________________________________________________ 0,8 bar pabs max ______________________________________________________ 30 bar Operating pressure range - outlet Pressure at port B Nominal pressure pN ______________________________________ 280 bar Peak pressure pmax ________________________________________ 350 bar (Pressure data to DIN 24312) Applications with intermittent operating pressures up to 315 bar at 10% duty are permissible. Limitation of pump output pressure spikes is possible with relief valve blocks mounted directly on flange connection, acc. to data sheets RE 25 880 and RE 25 890 to be ordered separately. Case drain pressure Maximum permissible pressure of leakage fluid (at port L, L1): Maximum 0,5 bar higher than the inlet pressure at port S, but no higher than 2 bar absolute. Direction of through flow S to B. Table of values (theoretical values, without taking into account mh and v: values rounded off) Size Displacement Max. speed
1)
Determination of inlet pressure pabs at suction port S or reduction of displacement for increasing speed.
1,2
1,6
1,4
1,1
1,2
1,0
1,0
0,9 0,8
0,9
0,7
0,8
0,9
1,0
28
45
71
100
140/High-S*
71 2200 2600 156 107 73 50 316 113 0,0083 1,6 33 2400 1900
100 2000 2400 200 150 93 70 445 159 0,0167 2,2 45 4000 2300
140/140 1800/2050 2100/2200 252/287 210 118/134 98 623 223 0,0242 3,0 60 4800 2800
Max. permitted speed (limit speed) with increased input pressure pabs bzw. Vg < Vg max Max. flow Max. power (p = 280 bar) Max. torque (p = 280 bar) Torque (p = 100 bar) Moment of inertia about drive axis Case volume Weight (without fluid) Permissible loading of drive shaft: Max. permissible radial force 2)
*= 1)
Po max at no max 1 at nE = 1500 min at Vg max at Vg max Tmax T J m max. axial force Fax max Fq max
High-Speed-Version These values are valid for an absolute pressure of 1 bar at the suction port S. By reducing the displacement or increasing the input pressure the speed can be increased as shown in the diagram. 2) Please consult us for higher radial forces. Determination of displacement Vg n v Flow qv = 1000 1,59 Vg p Vg p Torque T= = 100 mh 20 mh Power P= Tn 9549 = 2Tn 60 000 = qv p 600 t
application of forces
Vg = p = n = v = mh = t =
displacement [cm3] per revolution pressure differential [bar] speed [rpm] volumetric efficiency mechanical-hydraulic efficiency overall efficiency (t = v mh)
6/40
A10VSO | RE 92 711/03.00
Installation Notes
Optional installation position. The pump housing must be filled with fluid during commissioning and remain full when operating. In order to attain the lowest noise level, all connections (suction, pressure, case drain ports) must be linked by flexible couplings to tank. Avoid placing a check valve in the case drain line. This may, however, be permissible in individual cases, after consultation with us. 1. Vertical installation (shaft end upwards) The following installation conditions must be taken into account: 1.1. Arrangement in the reservoir Before installation fill pump housing, keeping it in a horizontal position. a) If the minimum fluid level is equal to or above the pump mounting face close port Lplugged, leave ports"L1" and S open; L1 piped and recommendation S piped (see Fig.1). b) If the minimum fluid level is below the pump mounting face pipe port L1 and S according to Fig. 2. Close port "L" with respect taking into consideration conditions in 1.2.1. 2. Horizontal installation The pump must be installed, so that "L" or "L1" is at the top. 2.1. Arrangement in the reservoir a) If the minimum fluid level is above the top of the pump, port "L1" closed, "L" and S should remain open, L piped and recommendation S piped (see Fig. 3) b) If the minimum fluid level is equal to or below the top of the pump, pipe ports "L" and possibly "S" as Fig. 4.; close port "L1". The conditions according to item 1.2.1.
Fluid
min. 200 mm
Fluid
L1
ht min
Fig. 3
L1
min. 200 mm
L
2.2. Installation outside the reservoir Fill the pump housing before commissioning. Pipe ports "S" and the higher port "L" or "L1". a) When mounting above the reservoir, see Fig. 4. Conditions according to 1.2.1.
Fig. 1
L1
Baffle
L1 S
h t min h max
ht min h max
1.2. Arrangement outside the reservoir Before installation fill the pump housing, keeping it in a horizontal position. For mounting above reservoir see Fig. 2. Limiting condition: 1.2.1. Minimum pump inlet pressure pabs min = 0.8 bar under both static and dynamic conditions. Note: Avoid mounting above reservoir wherever possible in order to achieve a low noise level. The permissible suction height h comes from the overall pressure loss, but may not be bigger than hmax = 800 mm (immersion depth ht min = 200 mm).
Fluid
Fig. 4 b) Mounting below the reservoir Pipe ports "L1" and S according to Fig.5, close port "L".
Fluid
Fluid
Baffle Fig. 2 Baffle
ht min
Overall pressure loss ptot = p1 + p2 + p3 (1 pabs min) = 0.2 bar p1: Pressure loss in pipe due to accelerating column of fluid
p1 = l dv 105 (bar) dt = density (kg/m3) l = pipe lenght (m) dv/dt = rate of change in fluid velocity (m/s2) h = height (m) = density (kg/m3) g = gravity = 9.81 m/s2
L1 S
p2: Pressure loss due to static head p2 = h g 105 (bar) p3: Line losses (elbows etc.)
Fig. 5
RE 92 711/03.00 | A10VSO
7/40
Size 100
qv max qv max qv Null zero
82 80
noise level LA [dB(A)]
qv Null zero
78 76 74 72 70 68 66 64 62 60 0 50
n = 1500 min-1
Size 45
76 74 qv max qv zero Null
n = 2600 min-1
72 70 68 66 64 62 60 58 0 50
n = 1500 min
-1
Size 140
84 82 80 78 76 74 72 70 68 66
n = 1500 min-1 n = 1800 min-1
Size 71
80 78 76 74 72 70 68 66 64 62 60 58 0 50 100 150 200 250 280 operating pressure p [bar]
n = 1500 min-1 n = 2200 min-1
8/40
A10VSO | RE 92 711/03.00
Pqv max
40 20
20
Pqv zero
50 100 150 200 250 280
10 0
80 60 40 20
Pqv max
40 30 20
Pqv zero
10 0
50
100
150
200
250
280
120 100 80
60 50 40
Pqv max
60 40 20 30 20
Pqv zero
10 0
50
100
150
200
250
280
flow qv [L/min]
160 140
80 70
qv
flow qv [L/min]
120 100
60
qv
50
flow qv [L/min]
90 80 60
40
qv
30
RE 92 711/03.00 | A10VSO
9/40
200 180
100 90
70
Pqv max
60 50 40 30
Pqv zero
20 10 0
50
100
150
200
250
280
260 240
130 120
100 90
Pqv max
80 70 60 50 40 30
40 20
Pqv zero
20 10 0
50
100
150
200
250
280
flow qv [L/min]
220
qv
110
flow qv [L/min]
160
qv
80
10/40
A10VSO | RE 92 711/03.00
Shaft P
ISO 3019/2 2 hole flange
9 6,3 2 32
90
V L B
26
80
45
45
L
14
174
100h8 22j6
M6
6h8
24,5-0,1
80
75
16 13 10 46 40
L1
164 206
S W
mech. displacement limiter
L1
View W
7/8"
1/4-20UNC-2B
16
32
30,2
M10; 17 deep
25,1 33,1 41
47,6 20
View V
B
M10; 17 deep
22,2
25 41
B S L/L1
Pressure port SAE 3/4" Suction port SAE 1 1/4" Case drain ports M18x1,5
74
32
RE 92 711/03.00 | A10VSO
11/40
Shaft P
9 96 6,3 3 36
45
45
B
26 14
8h9
100h8
25j6
M8
90
80,5
28 -0,2
90
19 13 10 52 45
L1
184 224
S W
mech. displacement limiter
93,5
140 184
L1
Ansicht W
69,9
1/4-20UNC-2B
16
35,7 M12; 20 deep
30 38 45,9
40
View V
52,4 25
M10; 17 deep
16 29.5
45.9
B S L/L1
Pressure port SAE 1" Suction port SAE 1 1/2" Case drain ports M22x1,5
83
12/40
V L B
33
104
45
45
L
18
10h9
125h8 32j6
M10
35-0,2
104
92
22 17 10 60 53 217 259
L1
S W
mech. displacement limiter
107,5 180 210
L1
View W
5/16-18UNC-2B
77,8
S
50
19
42,9
M12; 20 deep
25
58,7
1 1/4"
26,2
B
fixing hole thread M10; 17 deep for SAE 1 1/4"
5/16-18UNC-2B
30,2 52,4
38 51,6 58,7
Note: At pressure port B there are two SAE mountings available, each offset by 90. SAE 1 1/4" Standard pressure range, 3000 psi, for pressures up to 250 bar or SAE 1" Standard pressure range, 5000 psi, for pressures in excess of 250 bar. For operating pressures in excess of 250 bar or for new projects an SAE 1" pressure flange should be used.
B
S L/L1
Pressure port
Suction port Case drain ports
(Standard pressure range) bolt hole threads to either SAE 1" or SAE 1 1/4" (optional) (Standard pressure range) (L1 plugged at factory)
98
RE 92 711/03.00 | A10VSO
13/40
2 hole flange
10
ISO 3019/2
9 68
175
V L B
45
L
100
12h9
43-0,2 17,5 152
125h8 40k6
100
28 20 10 80 95 275 329
L1
S W
mech. displacement limiter
L1
1 1/2"
7/16-14UNC-2B
43,6 54 61,9
View W
mech. displacement limiter max.
View V
mech. displacement limiter min.
88,9
66,7
60
32
M12; 17 deep
50,8
M14; 19 deep
31,8
B S
L/L1
Pressure port
Suction port Case drain ports
102
95
14/40
A10VSO | RE 92 711/03.00
9 6,4 80
173
V L B
11 8, 5
45
L
14h9
180h8 45k6
M16
110
48,5-0,2
158,4
200
108
36 21 10 92 78 275 337,5
L1
S W
mech. displacement limiter
110
L1
5/8-11UNC-2B
36
55 67 75
View W
mech. displacement limiter max.
View V
mech. displacement limiter min.
88,9
66,7
63
32
S
M12; 17 deep
B
M14; 19 deep
50,8
31,8
B S
L/L1
Pressure port
Suction port Case drain ports
113
RE 92 711/03.00 | A10VSO
15/40
DG
The pump can be set to a minimum swivel anle by connecting an external switching pressure to port X. This pressure acts directly onto the control piston, a min. control pressure of at least 30 bar is required. The pump can only be switched between Vgmax and Vgmin. The switching pressure pSt depends on pump output pressure at a ratio of 1:4 pSt p = ____ 4 ^ V = gmax or p ____ ^ = Vgmin 4
switching pressure pSt in X = 0 bar switching pressure pSt in X 30 bar Controller data min. switching pressure max. switching pressure Unit dimensions Sizes 28...100
A1
L1
X
A4
S
Size 140
A1
S
Unit dimensions Size 28 45 71 100 140 A1 158 173 201 268 268 A2 100 110 123,5 128,5 153 A3 103,5 113,5 127,5 132,5 158 A4 3 3 3 3 4,6 X (plugged) R 1/4" R 1/4" R 1/4" R 1/4" M14x1,5 Ports B S L, L1 X
A2 A3
Pressure port Suction port Case drain ports (L1 plugged) Pilot pressure port (plugged)
A4
16/40
A10VSO | RE 92 711/03.00
DR
Pressure Control
The pressure controller serves to maintain a constant pressure in a hydraulic system within the control range of the pump. The pump therefore supplies only the amount of hydraulic fluid required by the system. Pressure may be steplessly set at the control valve. Static operating curve (at n1 = 1500 rpm; toil = 50 C)
hysteresis and pressure rise p
qv max
flow qv
S
adjustment range
qv min 20 280
L1
Dynamic operating curves The operating curves are mean values measured under test conditions with the unit mounted inside the tank. Conditions: n = 1500 rpm toil = 50 C Main relief set at 350 bar Load steps were obtained by suddenly opening and closing the pressure line with a pressure relief valve as load valve 1 m from the output flange of the pump.
350
Controller data Hysteresis and repetitive accuracy p __________ max. 3 bar Max. Pressure rise Size 28 45 71 100 140 p bar 4 6 8 10 12 Pilot oil requirement _________________ max. approx 3 L/min Flow loss at qvmax see pages 8 and 9. Control times tSA (ms) Size against 50 bar 28 60 45 80 71 100 100 125 140 130
Vgmax
Vgmin
RE 92 711/03.00 | A10VSO
17/40
Sizes 28100
Control valve installed here for clockwise rotation adjustment screw for pressure cut off
A2
On sizes 28 to 100 the DFR valve used has the flow control spool blocked in the factory and is not tested.
Size 140
control valve installed here for clockwise rotation adjustment screw for pressure cut off
A2
A1
A1
18/40
A10VSO | RE 92 711/03.00
Sizes 28100
S
displacement qv
L1
Size 140
adjustment range
qv min 20 280
X
operating pressure p [bar]
Controller data Hysteresis p _____________________________ max. 3 bar Max. pressure rise Size 28 45 71 100 140 p bar 4 6 8 10 12 Pilot oil requirement _____________________ approx. 4,5 L/min Flow loss at qvmax see pages 8 and 9.
L1
Ports B S L, L1 X
Pressure port Suction port Case drain ports ( L1 plugged) Pilot pressure port
RE 92 711/03.00 | A10VSO
19/40
Size 28100
control valve installed here for clockwise rotation adjustment screw for pressure cut off adjustment screw for differential pressure
A5
A3 A2
Size 140
control valve installed here for clockwise rotation adjustment screw for differential pressure
A5
B X
X
A1
A3 A2
A4 40 40 40 40 27
Port X M14x1,5; 12 deep M14x1,5; 12 deep with adaptor M14x1,5; 12 deep M14x1,5; 12 deep M14x1,5; 12 deep without adaptor
A4
A4
A1
20/40
A10VSO | RE 92 711/03.00
flow qv
adjustment range
qv min 20 280
qv (see table)
qv (see table)
Ports B S L, L1 X
L1
Pressure port Suction port Case drain ports ( L1 plugged) Pilot pressure port
speed n
Dynamic flow control operating curve The operating curves are average values measured under test conditions with the unit mounted inside the tank.
displacement Vg %
300 280 250 200 50 150 100 50 0 18
(stand by)
Differential pressure p: Adjustable between 10 and 22 bar (higher values on request). Standard setting: 14 bar. If a different setting is required please indicate in clear text. When port X is unloaded to tank a "zerostroke pressure" of p = 18 2 bar ("stand by") results (dependent on p).
100
350
75
Controller data Data pressure controller see page 16. Max. flow variation (hysteresis and increase) measured at drive speed n = 1500 rpm Size qvmax 28 1,0 45 1,8 71 2,8 100 4,0 140 6,0
25
L/min
DFR pilot oil consumption _________ max. approx. 3 ... 4,5 L/min DFR1 pilot oil consumption _____________ max. approx. 3 L/min Flow loss at qvmax see page 8 and 9.
RE 92 711/03.00 | A10VSO
21/40
Sizes 28100
control valve installed here for clockwise rotation adjustment srew pressure controller cut-off pressure adjustment srew for flow controller differential pressure
on DFR1
A3 A2
Size 140
control valve installed here for anti-clockwise rotation
A5
B X
adjustment srew for flow controller differential pressure adjustment srew pressure controller cut-off pressure
A4
X X orifice
plugged on DFR1
A3 A2
NG 28 45 71 100 140
A4 40 40 40 40 27
port X M14x1,5; 12 deep M14x1,5; 12 deep with adaptor M14x1,5; 12 deep M14x1,5; 12 deep M14x1,5; 12 deep without adaptor
A4
A1
A1
X X orifice plugged
22/40
A10VSO | RE 92 711/03.00
DFLR
In order to achieve a constant drive torque with a varying operating pressure, the swivel angle and with it the output flow of the axial piston pump is varied so that the product of flow and pressure remains constant. Constant flow control is possible below the power curve. Static operating curve
maximum power curve 100
Power valve
Flow qv [%]
75
S
Ports B S L, L1 X
L1
50
100
150
200
Pressure port Suction port Case drain ports ( L1 plugged) Pilot pressure port
The power curve is set at the factory, please state your requirements in clear text e.g. 20 kW at 1500 rpm. Controller data Technical data constant pressure control see page 16. Technical data flow control see page 20. Start of control ______________________________from 80 bar Pilot oil requirement _________________ max. approx. 5,5 L/min Flow loss at qvmax see pages 8 and 9.
RE 92 711/03.00 | A10VSO
23/40
Sizes 28100
control valve installed here for clockwise rotation adjustment srew pressure controller cut-off pressure
A3
B
adjustment srew for flow controller differential pressure
A1
X
A4
A6
A2
Size 140
control valve installed here for anti-clockwise rotation Power valve
A5
control valve installed here for clockwise rotation adjustment srew pressure controller cut-off pressure
A3
B
A6
X
A4
A1
A2
NG 28 45 71 100 140
A4 40 40 40 40 27
Port X M14x1,5; 12 deep M14x1,5; 12 deep M14x1,5; 12 deep M14x1,5; 12 deep M14x1,5; 12 deep
24/40
A10VSO | RE 92 711/03.00
FHD
The swivel angle of the pump and therefore its displacement is dependent on the pilot pressure pSt X present in port X. A constant pressure of py = 35 bar must be applied to port Y. The integral pressure control is steplessly adjustable. (Please state set value required in clear text).
MSt
Controller data Hysteresis 2 % of Vg max External pilot oil consumption in Y ____ max. approx. 3 ... 4,5 L/min Pressure rise p______________________________max. 4 bar Flow loss at qvmax see pages 8 and 9. Ports B S L, L1 X, Y MSt
Pressure port Suction port Case drain port ( L1 plugged) Pilot pressure ports Test port
L1
adjusment range
18
12
20
operating pressure p [bar]
280
RE 92 711/03.00 | A10VSO
25/40
Unit Dimensions FHD Pilot Pressure Dependent Flow Control with Pressure Cut-off
Before finishing your design, please request a certified drawing.
Sizes 28100
pilot valve installed here for anti-clockwise rotation
A5 A7
pilot valve installed here for clockwise rotation adjustment srew pressure controller cut-off pressure
A3
A1
A8
X
A4
A6
A10
MSt
A9 A12
A2
Size 140
pilot valve installed here for anti-clockwise rotation pilot valve installed here for clockwise rotation adjustment srew pressure controller cut-off pressure A9 A3
A5 A7
B X
A1 A8
Y X
A4
A6
S
A11 A12 A2
A4 40 40 40 40 27
A7 48 54 69 111 99
MSt Pipe dia 8x1,5 DIN 2391 Pipe dia 8x1,5 DIN 2391 Pipe dia 8x1,5 DIN 2391 Pipe dia 8x1,5 DIN 2391 Pipe dia 8x1,5 DIN 2391
A10
26/40
A10VSO | RE 92 711/03.00
Through drive
The A10VSO pump can be supplied with through drive in accordance with the type code on page 3. The through drive version is designated by the code numbers (KB2 K57). If no other pumps are fitted by the manufacturer, the simple type designation is sufficient. in this case, the delivery package comprises: Hub, fixing screws, seal and, if necessary, an adaptor flange. Combination pump By building on further pumps it is possible to obtain independent circuits: 1. If the combination pump consists of 2 A10VSO and if these are to be supplied assembled then the two order codes should be linked by means of a + sign. Ordering example: A10VSO 71 DR/31 LPPA12KB3 + A10VSO 28 DR/31 LPSA12N00 2. If a gear or radial piston pump is to be built on at the factory, please consult us. Permissible moment of inertia
m1
m2
m3
l1 l2 l3
m1, m2, m3 [kg] Pump mass l1, l2, l3 [mm] Distance to center of gravity 1 Tm = (m1 l1 + m2 l2 + m3 l3) 102 [Nm]
Size Permissible moment of inertia Tm Permissible moment of inertia Tm at dynamic mass acceleration 2 10g 98.1 m/sec Mass m1 To center of gravity l1
28 45 71 100 140 Nm 880 1370 2160 3000 4500 Nm 88 137 216 300 450
TGes
TD
The split in torque between pump 1 and 2 is optional. The max. permissible input torque Ttot as well as the max. permissible throughdrive torque T may not be exceeded.
D
Size 28 45 71 100 140 Max. permissible input torque at pump 1 with shaft "P" Ttot Nm 137 200 439 857 1206 Max. permissible through-drive torque TD Nm 137 200 439 778 1206 TD keyed shaft Nm 112 179 283 398 557
Size 28 45 71 100 140 Max. permissible input torque at pump 1 with shaft"S" Ttot Nm 198 319 6261104 1620 Max. permissible through-drive torque TD Nm 160 319 492 778 1266 TD keyed shaft Nm 112 179 283 398 557 Ttot TD = Max. permissible input torque at pump 1 = Max. permissible through-drive torque at through-drive to splined shaft
Size 28 45 71 100 140 Max. permissible input torque at pump 1 with shaft"R" Ttot Nm 225 400 644 Max. permissible through-drive torque TD Nm 176 365 548 TD keyed shaft Nm 112 179 283
RE 92 711/03.00 | A10VSO
27/40
A10VSO + A10VSO
A1 A2 A3 A4
main p. built-on p. A10VSO 18 A10VSO 28 A10VSO 45 A10VSO 71 A10VSO 100* A10VSO 140*
A1 164 164
A4
A1
A1
A10VSO 100 A2 A3 A4 483 522 555 613 533 562 595 664
A10VSO 140 A2 A3 A4 350 495 350 514 350 534 350 567 350 625 350 625 545 556 574 609 679 688
28/40
A10VSO | RE 92 711/03.00
Flange ISO 80, 2-hole for built-on A10VSO 10 (splined shaft S, mounting flange A, see RD 92713) or A10VSO 18 (splined shaft S or R, mounting flange A, see RD 92712) Order code KB2 section A - B
45
38 18,6
B
to pump mounting flange A1
10 A3
A3 14,5 16 16 20
For operation with HF-fluids please consider RE-data sheet of builton pump.
Flange ISO 80, 2-hole for built-on A10VSO 10 (shaft P, flange A, see RD 92713) or A10VSO 18 (shaft P, flange A, see RD 92712) Order code K51* section A - B
A3 14,5 16 16 20 20 20
A4 33 37 43 51 55 67
For operation with HF-fluids please consider RE-data sheet of builton pump.
*not for new applications, only permitted with reduced through drive torques, see page 26.
M10
80 +0.020
+0.050
109
RE 92 711/03.00 | A10VSO
29/40
Flange ISO 100, 2-hole for built-on A10VSO 28 (splined shaft S or R); Order code KB3 section A - B
45
41 A2
splined coupling 22-4 (SAE B) 7/8", 16/32 DP; 13 T
14
10
to pump mounting flange A1
A3
A3 14 18 18 24
Flange ISO 100, 2-hole for built-on A10VSO 28 (keyed shaft P) Order code K25* section A - B
A3 14 14 23 20 24
A4 37 43 51 55 62
*not for new applications, only permitted with reduced through drive torques, see page 26.
M12
100 +0.020
+0.050
30/40
A10VSO | RE 92 711/03.00
Flange ISO 100, 2-hole for built-on A10VSO 45 (splined S or R); order code KB4 section A - B
45
45,9 A2
14
10
to pump mounting flange A1
A3
A3 14 18 20 24
Flange ISO 100, 2-hole for built-on A10VSO 45 (keyed shaft P) order code K26*
section A - B
A3 14 23 20 24
A4 43 51 56 67
*not for new applications, only permitted with reduced through drive torques, see page 26.
M12
100 +0.020
+0.050
RE 92 711/03.00 | A10VSO
31/40
Flange ISO 125, 2-hole for built-on A10VSO 71 (splined shaft S or R); Order code KB5 section A - B
45
omitted on size 71
58,7 A2
omitted on size 71
10 A3
to pump mounting flange A1
A2 20 20 21
A3 18,5 25 32
Flange ISO 100, 2-hole for built-on A10VSO 71 (keyed shaft P) order code K27* section A - B
A3 18 20 24
A4 51 54 63
*not for new applications, only permitted with reduced through drive torques, see page 26.
M16
125 +0.020
+0.050
180
32/40
A10VSO | RE 92 711/03.00
Flange ISO 125, 2-hole for built-on A10VSO 100 (splined shaft S); Order code KB6 section A - B
45
A4 9
B
10
to pump mounting flange A1
A1 338 350
A4 65 77,3
Flange ISO 125, 2-hole for built-on A10VSO 100 (keyed shaft P) Order code K37* section A - B
A1 356 368
A4 71 80
*not for new applications, only permitted with reduced through drive torques, see page 26.
A3
125 +0.020
+0.050
180
RE 92 711/03.00 | A10VSO
33/40
Flange ISO 180, 4-hole for built-on A10VSO 140 (splined shaft S); Order code KB7 main pump NG 140
158.4
section A - B
77.3 10
M16
10
to pump mounting flange 350
Flange ISO 180, 4-hole for built-on A10VSO 140 (keyed shaft P) order code K59* section A - B
*not for new applications, only permitted with reduced through drive torques, see page 26.
180 +0.02
158.4
+0.05
34/40
A10VSO | RE 92 711/03.00
Flange SAE 82-2 (SAE A, 2-hole) for built-on external gear pump 1 PF2G2 (see RD 10030) or internal gear pump PGF2 (shaft J, flange U2, see RD 10213) Order code K01 section A - B 45 A4 A 9
10
10
B
Size main pump
28 45 71 100 140
A5 A5
M10; 16 deep M10; 16 deep M10; 20 deep M10; 20 deep M10; 20 deep
A1
204 229 267 338 350
A4
47 53 61 65 77
For operation with HF-fluids please consider RE-data sheet of builton pump.
Flange SAE 82-2 (SAE A, 2-hole) for built-on A10VSO 10 (shaft S, flange C, see RD 92713) or A10VSO 18 (shaft S, flange C, see RD 92712) Order code K52
45
section A - B A4 9
splined coupling 19-4 (SAE A-B) 3/4" 16/32 DP; 11 T
B
Size main pump
28 45 71 100 140
A5 A4
47,3 53,4 61,3 65 77
10
A1
206 229 267 338 350
A5
M10; 16 deep M10; 16 deep M10; 20 deep M10; 20 deep M10; 20 deep
For operation with HF-fluids please consider RE-data sheet of builton pump.
82.55 +0.020
+0.050
6 10
.5
82.55 +0.020
+0.050
6.5
RE 92 711/03.00 | A10VSO
35/40
Flange SAE 101-2 (SAE B, 2-hole) for built-on external gear pump 1PF2G3 (see RD 10039) Order code K02 section A - B 45
A4 9
omitted on size 28
B
Size main pump
28 45 71 100 140
omitted on size 28
10
to pump mounting flange A1
A1
204 229 267 338 350
A4
47 53 61 65 77
A5
M12; 15 deep M12; 18 deep M12; 20 deep M12; 20 deep M12; 20 deep
For operation with HF-fluids please consider RE-data sheet of builton pump.
Flange SAE 101-2 (SAE B, 2-hole) for built-on A10VO 28 (shaft S, see RD 92701) or internal gear pump PGF3 (shaft J, flange U2, see RD 10213) section A - B Order code K68 45 A A4
omitted on size 28
B
Size main pump
28 45 71 100 140
omitted on size 28
10
to pump mounting flange A1
A1
204 229 267 338 350
A4
47 53 61 65 80,8
A5
M12; 15 deep M12; 18 deep M12; 20 deep M12; 20 deep M12; 20 deep
For operation with HF-fluids please consider RE-data sheet of builton pump.
101.6 +0.020
+0.050
46 1
A5
101.6 +0.020
splined coupling 22-4 (SAE B) 7/8" 16/32 DP; 13 T
+0.050
46
A5
36/40
A10VSO | RE 92 711/03.00
Flange SAE 101-2 (SAE B, 2-hole) for built-on A10VO 45 (shaft S, see RD 92701) or internal gear pump PGH4 (shaft R, flange U2, see RD 10223) Order code K04 section A - B 45 A4 A A3
A5
B
Size main pump
28 45 71 100 140
10
to pump mounting flange A1
A1
204 229 267 338 350
A3
9 9 9 10 8
A4
47 53,4 61,3 65 77,3
A5
M12; 15 deep M12; 18 deep M12; 20 deep M12; 20 deep M12; 20 deep
For operation with HF-fluids please consider RE-data sheet of builton pump.
Flange SAE 127-2 (SAE C) for built-on A10VO 71 (shaft S, see RD 92701) Order code K07 section A - B
45
A4 A3
omitted on size 71
omitted on size 71
A5
B
13
to pump mounting flange A1
A1
267 339
A3
10 9
A4
61,3 65
A5
M16; 18 deep M16; 20 deep
For operation with HF-fluids please consider RE-data sheet of builton pump.
127 +0.020
+0.050
181
101.6 +0.020
splined coupling 32-4 (SAE C) 1 1/4" 12/24 DP; 14 T
+0.050
14
RE 92 711/03.00 | A10VSO
37/40
Flange SAE 127-2 (SAE C) for built-on A10VO 100 (shaft S, see RD 92701) or internal gear pump PGH5 (shaft R, flange U2, see RD 10223) Order code K24 section A - B
45
A4 A3
A5
B
to pump mounting flange A1
13
A1
338 350
A3
8 9
A4
65 77,3
A5
M16; 20 deep, right through M16; 32 deep
For operation with HF-fluids please consider RE-data sheet of builton pump.
Flange SAE 152-4 (SAE D) for built-on A10VO 140 (shaft S, see RD 92701); Order code K17 Schnitt A - B
161.6 77 10.5
M16
13
to pump mounting flange 350
For operation with HF-fluids please consider RE-data sheet of builton pump.
152.4 +0.02
161.6
+0.07
127 +0.020
splined coupling 44-4 (SAE D) 1 3/4" 8/16 DP; 13 T
+0.050
181
38/40
A10VSO | RE 92 711/03.00
Flange metric, 4-hole for built-on radial piston pump R4 (see RD 11263) Order code K57
section A - B
8 JS8
45
A4 9
28.3 +0.2
B
25 H7
Size main pump
28 45 71 100 140
9 A7
to pump mounting flange A1
A1
233 258 283 354 366
A4
47 71,5 68 70,5 84
A7
8 8 8 8 8
For operation with HF-fluids please consider RE-data sheet of builton pump.
63 H7
80
M8
RE 92 711/03.00 | A10VSO
39/40
40/40
A10VSO | RE 92 711/03.00
Brueninghaus Hydromatik GmbH Plant Horb An den Kelterwiesen 14 72160 Horb, Germany Tel. +49 (0) 74 51-92-0 Fax +49 (0) 74 51-82 21 [email protected] www.boschrexroth.com/brm
2002 by Brueninghaus Hydromatik GmbH, 72160 Horb All rights reserved. No part of this document may be reproduced or stored, processed, duplicated or circulated using electronic systems, in any form or by any means, without the prior written authorization of Brueninghaus Hydromatik GmbH. Violations shall give rise to claims for damages. The data specified above only serve to describe the product. They do not indicate any specific condition or suitability for a certain application. The information provided does not release the user from the obligation of own judgement and veification. It must be remembered that our products are subject to natural wear and ageing.