Product numbers based on a standard set of criteria are an essential prerequisite for DP-assisted handling of business. They serve to provide a clear means of communication between customers, regional organizations, head office and production workshops. They are determined for the products of the manufacturing locations / dispatch points of the regional office manufacturing and service centers of associated companies.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100%(2)100% found this document useful (2 votes)
9K views175 pages
MLFB Manual
Product numbers based on a standard set of criteria are an essential prerequisite for DP-assisted handling of business. They serve to provide a clear means of communication between customers, regional organizations, head office and production workshops. They are determined for the products of the manufacturing locations / dispatch points of the regional office manufacturing and service centers of associated companies.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 175
For Internal Use Only
Copyright (C) Siemens AG, 2011
All Rights Reserved
B
1
2
3
4
5
6
7
8
9
Machine-Readable Product Designation (MLFB)
Manual 2011 Version 1.0
Basics Electrical machines
Non-electrical machines Products with electric motor drives PRF heating and air-conditioning products High-voltage equipment Low-voltage equipment Transformers Current and voltage transformers Reactors, Capacitors For: Industry Energy Healthcare
Responsible: MLFB Central Working Group (ZAG MLFB) Cables, luminaires and lamps Installation material Electrical automotive products Room shilding Industrial automation systems Control and computer systems Converter systems Electricity meters Measurement technology products Protection devices and relays Factory assembled switchgear and control gear Distributors Group-specific and user-specific technology Field services and workshop operations
Basics
B
Contents 1 General 2 MLFB numbering system 3 Principles for etablishing the MLFB 4 Issuance and introduction of the MLFBs 5 Application 6 PMD (Product Master Data) 7 MLFB use from former Siemens Sections 8 Change history MLFB manual 2011 2
Basics
B 1. General 1.1. Purpose of product numbering Product numbers based on a standard set of criteria are an essential prerequisite for DP-assisted handling of business. They serve to provide a clear means of communication between customers, regional organizations, head office and production workshops with respect to: Preparation of quotations, selection and project planning Processing of orders Ordering Order acknowledgment Handling of products on stock Order processing in the dispatch points Delivery and dispatch Internal and external accounting Reporting and planning Exchange of product master data Service and warranty. 1.2. Range of application Product numbers are determined for the products of the manufacturing locations/dispatch points of the regional office manufacturing and service centers of associated companies and, if applicable, products from other vendors (including manufacture under license). marketed by Siemens AG in Germany and abroad.
The products are: Hardware products (equipment, systems, plants, devices etc.) Software products (operating systems, programming systems, process systems, control systems etc.) Standardized services (e.g. courses, examinations, building acceptance tests, standard wiring, installation services, standard project work, services) Technical documentation (Instruction Manuals, equipment manuals, training documentation etc.).
1.3. Definition of the numbering systems The most important numbering systems approved within Siemens AG are as follows: Machine-readable product designation (MLFB) according to SN 01030 Siemens item number (SSN) according to SN 01001 Technical numbering system according to SN 01060 according SN1000 https://ccs.siemens.com/CCS/CCS_en/siemens_stan dards_en.html
The MLFB numbering system is to be used in the sektors of Industry and Energy.
Each product must only be identified within Siemens AG by one product number. If products and modules of one Group are also marketed by other Groups, the product number of the originally responsible Group is retained. Group-internal numbering systems, e.g. factory drawing numbers, are not allowed in cross-group ordering/accounting (if necessary, numbering for spare parts in accordance with SN 01050).
1.4. Contact partners Please contact the following partners for inquiries, information and numerical codes:
Helmut Budenko, E D EA PRO BA S Nbg H Tel. +49 (911) 433-2165 Fax +49 (911) 433-7307 mailto:[email protected]
Wolfgang Ernst, E IT SF DM&SM 3 Erl S F Numbering designee of Energy Tel. +49 (9131) 18-4186 Fax +49 (9131) 18-5879 mailto:[email protected]
Markus Goldhofer, I IA CE ITS FT 1 Nbg M Numbering designee of I IA/DT, BT LV Tel. +49 (911) 895-6613 Fax +49 (911) 895-2917 mailto:[email protected]
Thomas Hildebrandt, I IA CE ITS FT 1 Nbg M Tel. +49 (911) 895-5549 Fax +49 (911) 895-2917 mailto:[email protected]
Helmut Scholz, I IA CE ITS PRI 4 Khe R Tel. +49 (721) 595-2010 Fax +49 (721) 595-6623 mailto:[email protected]
Otto Spiller, I IS IT OI-3 Erl-M Numbering designee of I IS Tel. +49 (9131) 7-46618 Fax: +49 (9131) 7-28007 mailto:[email protected]
MLFB manual 2011 3 Basics
B 1.5. Central Working Group (ZAG) MLFB The "central working group for machine-readable product codes", or ZAG MLFB, is made up of numbering designees and representatives from the former divisions A&D, I&S, PG and PTD and is responsible for arranging the products into super, main, and sub-groups of the MLFB. Since February 2008, new sub-groups will also have the 4th digit of the MLFB authorized by the ZAG MLFB.
2. MLFB numbering system The MLFB is the Order No. of a product and, at the same time, the model/system designation. The model/system designation starts with the first position of the MLFB and at least comprises the data positions 1 to 3, but, at the most, the first block of the product number. 2.1. Numbering scheme The machine-readable product designation (MLFB) at least consists of block 1 (7 digits) but, at the most, of 3 blocks (16 digits). Since June 2000 the first two blocks (12 digits) are necessary for newly released MLFB sub-groups.
In DP processes, the order codes are managed in one or more fields. A maximum of 32 order codes are possible. For machine-based order processing, order codes must be specified according to the following model see also section 2.4.3:
The following meanings apply: A The letter space (alpha space) without "O" (for order codes ANA without "I" and "O") N Digit (number space) - Separator (hyphen) + Separator (plus) Z 2-digit mandatory code to identify "special designs"
Assigning an MLFB to a sub-group therefore encompasses the data spaces 1 to 4. Applications must be sent in writing to the responsible contact center. All MLFB keys must be approved by the responsible ZAG MLFB member.
The centrally determined results are registered by the ZAG MLFB and published in the MLFB manual for SN 01030.
Note: MLFBs with 6 to 11 digits may still occur for older products. In addition to the MLFB, certain products have supplementary Order codes for further basic technical data, identified by "9" or "Z" within the MLFB, and/or special versions identified by "-Z" at the end of the number. The "ANA" Order code scheme applies to other basic technical data, and the "ANN" Order code scheme to special versions (see 2.3).
Block Nummernstelle Datenstelle 1 3 2 4 6 5 7 1 3 2 4 6 5 7 8 9 11 10 12 13 14 16 15 9 8 10 11 12 14 13 15 17 16 18 1 2 3 N A A N N N N N A N A N N A - N Z A - - Kurzangaben bis max. 8 pro B-Zeile Nummernstelle bis Datenstelle ... ... ... ... A A N N N A A N A N A N A A N N 1 3 2 4 6 5 7 9 8 10 11 12 28 29 1 2 3 30 31 Block Number position Data position Short codes Number position Data position Up to max. 8 per B-Linie Up to Basics
B 1.5. Central Working Group (ZAG) MLFB The "central working group for machine-readable product codes", or ZAG MLFB, is made up of numbering designees and representatives from the former divisions A&D, I&S, PG and PTD and is responsible for arranging the products into super, main, and sub-groups of the MLFB. Since February 2008, new sub-groups will also have the 4th digit of the MLFB authorized by the ZAG MLFB.
2. MLFB numbering system The MLFB is the Order No. of a product and, at the same time, the model/system designation. The model/system designation starts with the first position of the MLFB and at least comprises the data positions 1 to 3, but, at the most, the first block of the product number. 2.1. Numbering scheme The machine-readable product designation (MLFB) at least consists of block 1 (7 digits) but, at the most, of 3 blocks (16 digits). Since June 2000 the first two blocks (12 digits) are necessary for newly released MLFB sub-groups.
In DP processes, the order codes are managed in one or more fields. A maximum of 32 order codes are possible. For machine-based order processing, order codes must be specified according to the following model see also section 2.4.3:
The following meanings apply: A The letter space (alpha space) without "O" (for order codes ANA without "I" and "O") N Digit (number space) - Separator (hyphen) + Separator (plus) Z 2-digit mandatory code to identify "special designs"
Assigning an MLFB to a sub-group therefore encompasses the data spaces 1 to 4. Applications must be sent in writing to the responsible contact center. All MLFB keys must be approved by the responsible ZAG MLFB member.
The centrally determined results are registered by the ZAG MLFB and published in the MLFB manual for SN 01030.
Note: MLFBs with 6 to 11 digits may still occur for older products. In addition to the MLFB, certain products have supplementary Order codes for further basic technical data, identified by "9" or "Z" within the MLFB, and/or special versions identified by "-Z" at the end of the number. The "ANA" Order code scheme applies to other basic technical data, and the "ANN" Order code scheme to special versions (see 2.3).
Block Nummernstelle Datenstelle 1 3 2 4 6 5 7 1 3 2 4 6 5 7 8 9 11 10 12 13 14 16 15 9 8 10 11 12 14 13 15 17 16 18 1 2 3 N A A N N N N N A N A N N A - N Z A - - Kurzangaben bis max. 8 pro B-Zeile Nummernstelle bis Datenstelle ... ... ... ... A A N N N A A N A N A N A A N N 1 3 2 4 6 5 7 9 8 10 11 12 28 29 1 2 3 30 31 Block Number position Data position Short codes Number position Data position Up to max. 8 per B-Linie Up to Basics
B 1.5. Central Working Group (ZAG) MLFB The "central working group for machine-readable product codes", or ZAG MLFB, is made up of numbering designees and representatives from the former divisions A&D, I&S, PG and PTD and is responsible for arranging the products into super, main, and sub-groups of the MLFB. Since February 2008, new sub-groups will also have the 4th digit of the MLFB authorized by the ZAG MLFB.
2. MLFB numbering system The MLFB is the Order No. of a product and, at the same time, the model/system designation. The model/system designation starts with the first position of the MLFB and at least comprises the data positions 1 to 3, but, at the most, the first block of the product number. 2.1. Numbering scheme The machine-readable product designation (MLFB) at least consists of block 1 (7 digits) but, at the most, of 3 blocks (16 digits). Since June 2000 the first two blocks (12 digits) are necessary for newly released MLFB sub-groups.
In DP processes, the order codes are managed in one or more fields. A maximum of 32 order codes are possible. For machine-based order processing, order codes must be specified according to the following model see also section 2.4.3:
The following meanings apply: A The letter space (alpha space) without "O" (for order codes ANA without "I" and "O") N Digit (number space) - Separator (hyphen) + Separator (plus) Z 2-digit mandatory code to identify "special designs"
Assigning an MLFB to a sub-group therefore encompasses the data spaces 1 to 4. Applications must be sent in writing to the responsible contact center. All MLFB keys must be approved by the responsible ZAG MLFB member.
The centrally determined results are registered by the ZAG MLFB and published in the MLFB manual for SN 01030.
Note: MLFBs with 6 to 11 digits may still occur for older products. In addition to the MLFB, certain products have supplementary Order codes for further basic technical data, identified by "9" or "Z" within the MLFB, and/or special versions identified by "-Z" at the end of the number. The "ANA" Order code scheme applies to other basic technical data, and the "ANN" Order code scheme to special versions (see 2.3).
Block Nummernstelle Datenstelle 1 3 2 4 6 5 7 1 3 2 4 6 5 7 8 9 11 10 12 13 14 16 15 9 8 10 11 12 14 13 15 17 16 18 1 2 3 N A A N N N N N A N A N N A - N Z A - - Kurzangaben bis max. 8 pro B-Zeile Nummernstelle bis Datenstelle ... ... ... ... A A N N N A A N A N A N A A N N 1 3 2 4 6 5 7 9 8 10 11 12 28 29 1 2 3 30 31 Block Number position Data position Short codes Number position Data position Up to max. 8 per B-Linie Up to MLFB manual 2011 4 Basics
B 2.2. MLFB structure
The MLFBs consist of a combination of numbers and letters. Letters (A for alphabetical), numbers (N for numerical) and separators (-) are always located at the positions defined in the above numbering scheme. The letters "I" and "O" are not permissible, so as to avoid confusion with the digits "1" and "0".
Block Nummernstelle (NS) Datenstelle (DS) Obergruppe 1 bis 9 1 "Technisches Gebiet" 9 Hauptgruppe A bis Z A "Produktart" (ohne I und O) Z Untergruppe A bis Z A "Produktgruppe" (ohne I und O) Z Ziffern 0 bis 9; 0 Merkmale/Ausprgungen 9 Ziffern 0 bis 9; 0 0 Merkmale/Ausprgungen 9 9 Ziffern 0 bis 8; 0 0 0 0 0 0 Merkmale/Ausprgungen 8 8 8 8 8 8 Kennzeichen fr 9 9 9 9 9 9 "Anormale Technische Grundangaben" (siehe 2.3.1) Buchstaben A bis X (ohne I und O) A Merkmale/Ausprgungen X Kennzeichen fr bestimmte Y Auslandsfertigung (siehe 3.3.3) Kennzeichen fr "Anormale Z Technische Grundangaben" (siehe 2.3.1) Buchstaben A bis Y (ohne I und O) A A A Merkmale/Ausprgungen Y Y Y Kennzeichen fr "Anormale Z Z Z Technische Grundangaben" (siehe 2.3.1) N A A N N N N N A N A N N A - N Z A 1 3 2 4 6 5 7 1 3 2 4 6 5 7 8 9 11 10 12 13 14 16 15 9 8 10 11 12 14 13 15 17 16 18 1 2 3 Block
Number position
Data position Superordinate group 1 to 9
"Technical area" Main group A to Z
"Product character"
(without I and O) Subgroup A to Z
"Product group"
(without I and O) Figures 1 to 9, Features/characteristics Figures 1 to 9, Features/characteristics Figures 1 to 8, Features/characteristics Code for "Further Technical Basic Data (2.3.1.) Letters A to Y (without I and O) Code for certain manufacture
Features/characteristics Code for "Further Technical Basic Data" (2.3.1.) Letters A to Y (without I and O), Features/characteristics Code for "Further Technical Basic Data" (2.3.1.) Y Basics
B 2.2. MLFB structure
The MLFBs consist of a combination of numbers and letters. Letters (A for alphabetical), numbers (N for numerical) and separators (-) are always located at the positions defined in the above numbering scheme. The letters "I" and "O" are not permissible, so as to avoid confusion with the digits "1" and "0".
Block Nummernstelle (NS) Datenstelle (DS) Obergruppe 1 bis 9 1 "Technisches Gebiet" 9 Hauptgruppe A bis Z A "Produktart" (ohne I und O) Z Untergruppe A bis Z A "Produktgruppe" (ohne I und O) Z Ziffern 0 bis 9; 0 Merkmale/Ausprgungen 9 Ziffern 0 bis 9; 0 0 Merkmale/Ausprgungen 9 9 Ziffern 0 bis 8; 0 0 0 0 0 0 Merkmale/Ausprgungen 8 8 8 8 8 8 Kennzeichen fr 9 9 9 9 9 9 "Anormale Technische Grundangaben" (siehe 2.3.1) Buchstaben A bis X (ohne I und O) A Merkmale/Ausprgungen X Kennzeichen fr bestimmte Y Auslandsfertigung (siehe 3.3.3) Kennzeichen fr "Anormale Z Technische Grundangaben" (siehe 2.3.1) Buchstaben A bis Y (ohne I und O) A A A Merkmale/Ausprgungen Y Y Y Kennzeichen fr "Anormale Z Z Z Technische Grundangaben" (siehe 2.3.1) N A A N N N N N A N A N N A - N Z A 1 3 2 4 6 5 7 1 3 2 4 6 5 7 8 9 11 10 12 13 14 16 15 9 8 10 11 12 14 13 15 17 16 18 1 2 3 Block
Number position
Data position Superordinate group 1 to 9
"Technical area" Main group A to Z
"Product character"
(without I and O) Subgroup A to Z
"Product group"
(without I and O) Figures 1 to 9, Features/characteristics Figures 1 to 9, Features/characteristics Figures 1 to 8, Features/characteristics Code for "Further Technical Basic Data (2.3.1.) Letters A to Y (without I and O) Code for certain manufacture
Features/characteristics Code for "Further Technical Basic Data" (2.3.1.) Letters A to Y (without I and O), Features/characteristics Code for "Further Technical Basic Data" (2.3.1.) Y Basics
B 2.2. MLFB structure
The MLFBs consist of a combination of numbers and letters. Letters (A for alphabetical), numbers (N for numerical) and separators (-) are always located at the positions defined in the above numbering scheme. The letters "I" and "O" are not permissible, so as to avoid confusion with the digits "1" and "0".
Block Nummernstelle (NS) Datenstelle (DS) Obergruppe 1 bis 9 1 "Technisches Gebiet" 9 Hauptgruppe A bis Z A "Produktart" (ohne I und O) Z Untergruppe A bis Z A "Produktgruppe" (ohne I und O) Z Ziffern 0 bis 9; 0 Merkmale/Ausprgungen 9 Ziffern 0 bis 9; 0 0 Merkmale/Ausprgungen 9 9 Ziffern 0 bis 8; 0 0 0 0 0 0 Merkmale/Ausprgungen 8 8 8 8 8 8 Kennzeichen fr 9 9 9 9 9 9 "Anormale Technische Grundangaben" (siehe 2.3.1) Buchstaben A bis X (ohne I und O) A Merkmale/Ausprgungen X Kennzeichen fr bestimmte Y Auslandsfertigung (siehe 3.3.3) Kennzeichen fr "Anormale Z Technische Grundangaben" (siehe 2.3.1) Buchstaben A bis Y (ohne I und O) A A A Merkmale/Ausprgungen Y Y Y Kennzeichen fr "Anormale Z Z Z Technische Grundangaben" (siehe 2.3.1) N A A N N N N N A N A N N A - N Z A 1 3 2 4 6 5 7 1 3 2 4 6 5 7 8 9 11 10 12 13 14 16 15 9 8 10 11 12 14 13 15 17 16 18 1 2 3 Block
Number position
Data position Superordinate group 1 to 9
"Technical area" Main group A to Z
"Product character"
(without I and O) Subgroup A to Z
"Product group"
(without I and O) Figures 1 to 9, Features/characteristics Figures 1 to 9, Features/characteristics Figures 1 to 8, Features/characteristics Code for "Further Technical Basic Data (2.3.1.) Letters A to Y (without I and O) Code for certain manufacture
Features/characteristics Code for "Further Technical Basic Data" (2.3.1.) Letters A to Y (without I and O), Features/characteristics Code for "Further Technical Basic Data" (2.3.1.) Y MLFB manual 2011 5 Basics
B 2.3. MLFB with Order codes In many cases, products available in multiple versions cannot be fully identified using the 16 digits of the MLFB. It is possible to handle these products automatically, however, with the aid of "order codes", which are codes for the special designs.
2.3.1. Order codes for "Further basic technical data" (ANA) "Technical Basic Specifications" refer to the technical features and characteristics that are already encoded in certain letters or digits of the productnumber. If you want a design that goes beyond this, an ID must be used for digits 7 through 16 according to the specification in the catalog.
2.3.2. Order codes for "Special designs" (A N N) "Special designs" refers to further technical features that are not encoded in certain letters or digits of the product number beyond the "technical basic specifications". When ordering, the identifier "-Z" must be added to the MLFB for "special designs". The order code is in the "ANN" format.
There are 2 types of order codes: Order codes for "Further technical basic specifications" A N A for the 16 digits and letters of the MLFB and order codes for "special designs" A N N additional technical specifications beyond the 16 digits and letters of the MLFB
"9" for a digit or "Z" for a letter
The order code is in the "ANA" format. The first letter (alphabetic) specifies the corresponding data space in the MLFB.
Datenstelle (DS) Buchstabe fr DS N A A N N N 9 9 Z Z 9 9 9 Z Z 9 Muss-Kennzeichen fr "Anormale Technische Grundangabe" Buchstabe A bis X (ohne I und O) Buchstabe Y (2.3.3) Ziffern 0 bis 9 Buchstaben G bis R entsprechend der Da- tenstelle in der MLFB, in der eine 9 bzw. ein Z steht. Beispiel: L1A bedeutet Kurzangabe zur Datenstelle 11 der MLFB. Es ist jeweils nur eine auf eine Datenstelle bezogene Kurzangabe im Format ANA zugelassen A A N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 - - - - - - G J H K L M N P Q R ... ... Muss-Kennzeichen fr "Besondere 0 bis 9 Ausfhrung" A bis X (ohne O) Schreib- und Y(siehe 2.3.3) oder I (siehe 2.3.4) Datenstelle Es sind mehrere Kurzangaben im Format ANN zugelassen. - A N N N A N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 Z
Data position (DS) Letter for DS Compulsory identifier for "Further Technical Basic Data" Letter A to X (without I and O), Letter Y (2.3.3.)
Figures 0 to 9 Letters G to R in accordance with the Data position in the MLFB, in which there is a "9" or a "Z" Example: L1A means short code for the data position 11 of the MLFB. Only one short code referred to a data position in each case is permitted in the format "ANA". 0 to 9
A to X (without O) Y (2.3.3.) Several short codes are permitted in the format "ANN". Compulsory identifier for "Special version"
Charakter and data position Basics
B 2.3. MLFB with Order codes In many cases, products available in multiple versions cannot be fully identified using the 16 digits of the MLFB. It is possible to handle these products automatically, however, with the aid of "order codes", which are codes for the special designs.
2.3.1. Order codes for "Further basic technical data" (ANA) "Technical Basic Specifications" refer to the technical features and characteristics that are already encoded in certain letters or digits of the productnumber. If you want a design that goes beyond this, an ID must be used for digits 7 through 16 according to the specification in the catalog.
2.3.2. Order codes for "Special designs" (A N N) "Special designs" refers to further technical features that are not encoded in certain letters or digits of the product number beyond the "technical basic specifications". When ordering, the identifier "-Z" must be added to the MLFB for "special designs". The order code is in the "ANN" format.
There are 2 types of order codes: Order codes for "Further technical basic specifications" A N A for the 16 digits and letters of the MLFB and order codes for "special designs" A N N additional technical specifications beyond the 16 digits and letters of the MLFB
"9" for a digit or "Z" for a letter
The order code is in the "ANA" format. The first letter (alphabetic) specifies the corresponding data space in the MLFB.
Datenstelle (DS) Buchstabe fr DS N A A N N N 9 9 Z Z 9 9 9 Z Z 9 Muss-Kennzeichen fr "Anormale Technische Grundangabe" Buchstabe A bis X (ohne I und O) Buchstabe Y (2.3.3) Ziffern 0 bis 9 Buchstaben G bis R entsprechend der Da- tenstelle in der MLFB, in der eine 9 bzw. ein Z steht. Beispiel: L1A bedeutet Kurzangabe zur Datenstelle 11 der MLFB. Es ist jeweils nur eine auf eine Datenstelle bezogene Kurzangabe im Format ANA zugelassen A A N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 - - - - - - G J H K L M N P Q R ... ... Muss-Kennzeichen fr "Besondere 0 bis 9 Ausfhrung" A bis X (ohne O) Schreib- und Y(siehe 2.3.3) oder I (siehe 2.3.4) Datenstelle Es sind mehrere Kurzangaben im Format ANN zugelassen. - A N N N A N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 Z
Data position (DS) Letter for DS Compulsory identifier for "Further Technical Basic Data" Letter A to X (without I and O), Letter Y (2.3.3.)
Figures 0 to 9 Letters G to R in accordance with the Data position in the MLFB, in which there is a "9" or a "Z" Example: L1A means short code for the data position 11 of the MLFB. Only one short code referred to a data position in each case is permitted in the format "ANA". 0 to 9
A to X (without O) Y (2.3.3.) Several short codes are permitted in the format "ANN". Compulsory identifier for "Special version"
Charakter and data position Basics
B 2.3. MLFB with Order codes In many cases, products available in multiple versions cannot be fully identified using the 16 digits of the MLFB. It is possible to handle these products automatically, however, with the aid of "order codes", which are codes for the special designs.
2.3.1. Order codes for "Further basic technical data" (ANA) "Technical Basic Specifications" refer to the technical features and characteristics that are already encoded in certain letters or digits of the productnumber. If you want a design that goes beyond this, an ID must be used for digits 7 through 16 according to the specification in the catalog.
2.3.2. Order codes for "Special designs" (A N N) "Special designs" refers to further technical features that are not encoded in certain letters or digits of the product number beyond the "technical basic specifications". When ordering, the identifier "-Z" must be added to the MLFB for "special designs". The order code is in the "ANN" format.
There are 2 types of order codes: Order codes for "Further technical basic specifications" A N A for the 16 digits and letters of the MLFB and order codes for "special designs" A N N additional technical specifications beyond the 16 digits and letters of the MLFB
"9" for a digit or "Z" for a letter
The order code is in the "ANA" format. The first letter (alphabetic) specifies the corresponding data space in the MLFB.
Datenstelle (DS) Buchstabe fr DS N A A N N N 9 9 Z Z 9 9 9 Z Z 9 Muss-Kennzeichen fr "Anormale Technische Grundangabe" Buchstabe A bis X (ohne I und O) Buchstabe Y (2.3.3) Ziffern 0 bis 9 Buchstaben G bis R entsprechend der Da- tenstelle in der MLFB, in der eine 9 bzw. ein Z steht. Beispiel: L1A bedeutet Kurzangabe zur Datenstelle 11 der MLFB. Es ist jeweils nur eine auf eine Datenstelle bezogene Kurzangabe im Format ANA zugelassen A A N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 - - - - - - G J H K L M N P Q R ... ... Muss-Kennzeichen fr "Besondere 0 bis 9 Ausfhrung" A bis X (ohne O) Schreib- und Y(siehe 2.3.3) oder I (siehe 2.3.4) Datenstelle Es sind mehrere Kurzangaben im Format ANN zugelassen. - A N N N A N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 Z
Data position (DS) Letter for DS Compulsory identifier for "Further Technical Basic Data" Letter A to X (without I and O), Letter Y (2.3.3.)
Figures 0 to 9 Letters G to R in accordance with the Data position in the MLFB, in which there is a "9" or a "Z" Example: L1A means short code for the data position 11 of the MLFB. Only one short code referred to a data position in each case is permitted in the format "ANA". 0 to 9
A to X (without O) Y (2.3.3.) Several short codes are permitted in the format "ANN". Compulsory identifier for "Special version"
Charakter and data position MLFB manual 2011 6 Basics
B 2.3.3. Order codes requiring additional data ( A N Y ) or ( Y N N ) In some cases, a product version cannot be precisely technically defined in the catalog, for example the inscription on a measuring point label of recorders. However, the price for this version has been defined. The requested version e.g. the exact inscription still has to be specified in plain text.
2.3.4. Combination of Order codes Combinations of "Other basic technical data" and various "Special versions" can be represented by stringing together Order codes in any sequence, where a "+" sign must be inserted between two Order codes, without leaving spaces in between.
In order to be able to access the PMD or to enable DP handling, Order codes must have the format A N Y for "Further basic technical data" plus plain text, and Y N N for "Special versions", plus plain text.
The separators " + " are data spaces. The number of order codes is not limited by the MLFB system, but it can be limited by DP processes, if applicable. It is recommended to put a blank space between the "-Z" and the first order code.
9 Zusatzangaben in Klartext zu YNN Zusatzangaben in Klartext zu - A Y N N Y N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 Z . . . . max. 8 Kurzangaben pro B-Zeile - Z A A N N N A A N A A N N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 A A N N Additional data in plaintext for YNN Additional data in plaintext for ANY Maximum 32 short codes
Basics
B 2.3.3. Order codes requiring additional data ( A N Y ) or ( Y N N ) In some cases, a product version cannot be precisely technically defined in the catalog, for example the inscription on a measuring point label of recorders. However, the price for this version has been defined. The requested version e.g. the exact inscription still has to be specified in plain text.
2.3.4. Combination of Order codes Combinations of "Other basic technical data" and various "Special versions" can be represented by stringing together Order codes in any sequence, where a "+" sign must be inserted between two Order codes, without leaving spaces in between.
In order to be able to access the PMD or to enable DP handling, Order codes must have the format A N Y for "Further basic technical data" plus plain text, and Y N N for "Special versions", plus plain text.
The separators " + " are data spaces. The number of order codes is not limited by the MLFB system, but it can be limited by DP processes, if applicable. It is recommended to put a blank space between the "-Z" and the first order code.
9 Zusatzangaben in Klartext zu YNN Zusatzangaben in Klartext zu - A Y N N Y N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 Z . . . . max. 8 Kurzangaben pro B-Zeile - Z A A N N N A A N A A N N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 A A N N Additional data in plaintext for YNN Additional data in plaintext for ANY Maximum 32 short codes
Basics
B 2.3.3. Order codes requiring additional data ( A N Y ) or ( Y N N ) In some cases, a product version cannot be precisely technically defined in the catalog, for example the inscription on a measuring point label of recorders. However, the price for this version has been defined. The requested version e.g. the exact inscription still has to be specified in plain text.
2.3.4. Combination of Order codes Combinations of "Other basic technical data" and various "Special versions" can be represented by stringing together Order codes in any sequence, where a "+" sign must be inserted between two Order codes, without leaving spaces in between.
In order to be able to access the PMD or to enable DP handling, Order codes must have the format A N Y for "Further basic technical data" plus plain text, and Y N N for "Special versions", plus plain text.
The separators " + " are data spaces. The number of order codes is not limited by the MLFB system, but it can be limited by DP processes, if applicable. It is recommended to put a blank space between the "-Z" and the first order code.
9 Zusatzangaben in Klartext zu YNN Zusatzangaben in Klartext zu - A Y N N Y N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 Z . . . . max. 8 Kurzangaben pro B-Zeile - Z A A N N N A A N A A N N 1 3 2 4 6 5 7 9 8 10 11 12 13 14 15 16 A A N N Additional data in plaintext for YNN Additional data in plaintext for ANY Maximum 32 short codes
MLFB manual 2011 7 Basics
B 2.4. MLFB notation It is permissible to interrupt block 1 using a gap (space) to make it easier to recognize the number, e.g. 3TF46 22. The space is taking into consideration in catalogs and price lists, but is left out when entering the number into the data processing system on a computer. If the number is written by hand in orders or correspondence, the MLFB should not contain any further spaces.
2.4.1. Catalog notation If possible, the MLFB should be written completely in a catalog. Products having a wide range of versions should be composed in a classified manner as far as possible, i.e. certain product features should be assigned to the individual data positions (basic technical data). For clarity reasons and to save space, it is often useful to break down these classifying product numbers in the catalog into an MLFB group and one or more supplements. A supplement may also comprise several consecutive data positions. A supplement position is shown by a dot or a little box. Examples:
The complete product number, when applied, must be formed in several stages by combining the MLFB group with the supplements in accordance with the catalog data. An MLFB whose supplement positions have not all been specified is incomplete and cannot be ordered.
2.4.2. Documentation notation In orders, delivery notes, invoices etc., MLFBs, Order codes and any additional data in plain text are written in the following order:
MLFB 1LA5 186-4AA69-Z Short Codes M1F+A11+Y54 Plaintext for Y54 Special paint RAL 7005
2.4.3. Specification in EDIFACT orders Text mode Description Example Consequence Interrupt of data processing at the manufacturer Transfer into the order acknowledg- ment/ORDRSP Transfer into delivery- note and attendant invoices PIA1 *IS Encoded Short Code M1F+A11*Y01 no optional yes PIA1 *TC Technical additional for Y-Short- Codes standardized text, e.g. Y01 0 bis 400mbar no optional yes PIA1 *TE Plain text for tecnical codes, if the MLFB has Y-Order code or un case of older MLFBs without Order Codes.
GG-individual interrupt possible
3WE43 14-1 . . . . Rumpf-Nr. 4 Ergnzungsstellen 7ND2 142 - Rumpf-Nr. 9 Ergnzungsstellen Body number 4 supplement positions Body number 9 supplement positions Basics
B 2.4. MLFB notation It is permissible to interrupt block 1 using a gap (space) to make it easier to recognize the number, e.g. 3TF46 22. The space is taking into consideration in catalogs and price lists, but is left out when entering the number into the data processing system on a computer. If the number is written by hand in orders or correspondence, the MLFB should not contain any further spaces.
2.4.1. Catalog notation If possible, the MLFB should be written completely in a catalog. Products having a wide range of versions should be composed in a classified manner as far as possible, i.e. certain product features should be assigned to the individual data positions (basic technical data). For clarity reasons and to save space, it is often useful to break down these classifying product numbers in the catalog into an MLFB group and one or more supplements. A supplement may also comprise several consecutive data positions. A supplement position is shown by a dot or a little box. Examples:
The complete product number, when applied, must be formed in several stages by combining the MLFB group with the supplements in accordance with the catalog data. An MLFB whose supplement positions have not all been specified is incomplete and cannot be ordered.
2.4.2. Documentation notation In orders, delivery notes, invoices etc., MLFBs, Order codes and any additional data in plain text are written in the following order:
MLFB 1LA5 186-4AA69-Z Short Codes M1F+A11+Y54 Plaintext for Y54 Special paint RAL 7005
2.4.3. Specification in EDIFACT orders Text mode Description Example Consequence Interrupt of data processing at the manufacturer Transfer into the order acknowledg- ment/ORDRSP Transfer into delivery- note and attendant invoices PIA1 *IS Encoded Short Code M1F+A11*Y01 no optional yes PIA1 *TC Technical additional for Y-Short- Codes standardized text, e.g. Y01 0 bis 400mbar no optional yes PIA1 *TE Plain text for tecnical codes, if the MLFB has Y-Order code or un case of older MLFBs without Order Codes.
GG-individual interrupt possible
3WE43 14-1 . . . . Rumpf-Nr. 4 Ergnzungsstellen 7ND2 142 - Rumpf-Nr. 9 Ergnzungsstellen Body number 4 supplement positions Body number 9 supplement positions Basics
B 2.4. MLFB notation It is permissible to interrupt block 1 using a gap (space) to make it easier to recognize the number, e.g. 3TF46 22. The space is taking into consideration in catalogs and price lists, but is left out when entering the number into the data processing system on a computer. If the number is written by hand in orders or correspondence, the MLFB should not contain any further spaces.
2.4.1. Catalog notation If possible, the MLFB should be written completely in a catalog. Products having a wide range of versions should be composed in a classified manner as far as possible, i.e. certain product features should be assigned to the individual data positions (basic technical data). For clarity reasons and to save space, it is often useful to break down these classifying product numbers in the catalog into an MLFB group and one or more supplements. A supplement may also comprise several consecutive data positions. A supplement position is shown by a dot or a little box. Examples:
The complete product number, when applied, must be formed in several stages by combining the MLFB group with the supplements in accordance with the catalog data. An MLFB whose supplement positions have not all been specified is incomplete and cannot be ordered.
2.4.2. Documentation notation In orders, delivery notes, invoices etc., MLFBs, Order codes and any additional data in plain text are written in the following order:
MLFB 1LA5 186-4AA69-Z Short Codes M1F+A11+Y54 Plaintext for Y54 Special paint RAL 7005
2.4.3. Specification in EDIFACT orders Text mode Description Example Consequence Interrupt of data processing at the manufacturer Transfer into the order acknowledg- ment/ORDRSP Transfer into delivery- note and attendant invoices PIA1 *IS Encoded Short Code M1F+A11*Y01 no optional yes PIA1 *TC Technical additional for Y-Short- Codes standardized text, e.g. Y01 0 bis 400mbar no optional yes PIA1 *TE Plain text for tecnical codes, if the MLFB has Y-Order code or un case of older MLFBs without Order Codes.
GG-individual interrupt possible
3WE43 14-1 . . . . Rumpf-Nr. 4 Ergnzungsstellen 7ND2 142 - Rumpf-Nr. 9 Ergnzungsstellen Body number 4 supplement positions Body number 9 supplement positions MLFB manual 2011 8 Basics
B
3. Principles for etablishing the MLFB 3.1. General Technical criteria are decisive when assigning the product features and their characteristics to the data positions of the MLFB scheme. The function of a product is the prime consideration when defining the MLFB. The technical characteristics and their attributes in the catalog correspond to the ranking of the criteria in the data positions of the MLFB (4.1). If possible, the data particularly decisive for the price should also be coded as far as possible at the front of the MLFB. Any aspects which may be subject to change (e.g. organizational) must not be taking into account. The manufacturing plant does not form part of the product number. SN 37040 applies to the identification of the manufacturing plant on products. The product number must satisfy the requirements of personal handling and electronic data processing. The unambiguity and uniformity of the product numbers and the reserve available for new products are monitored centrally by the central working group ZAG MLFB. For these reasons, no department may itself define or change any product numbers. In the event of faults, it must be expected that any MLFBs which have not been agreed upon will be changed!
3.2. MLFB for products manufactured abroad Products which are manufactured abroad by a regional company, constructed under license or purchased from another vendor are assigned a product number according to the same rules as the original Siemens products. The following points apply in addition.
3.2.1. Characters reserved until now The characters reserved until now: 0 at data position 4 Y at data position 9 and Order codes I.. are released for normal use since 01.06.2006
The appointed MLFBs with these chareacters until now remains valid furthermore.
3.2.2. Identification of manufacturing plant The manufacturing plant is not coded in the product number in the case of products manufactured abroad either, but is identified on the rating plate or product label in accordance with SN 37040.
3.3. Product numbers in the case of changed products If a product is changed, the responsible parties referred to in Section 1.4 will check whether a new product number has to be defined or whether the previous number can be retained. It should be remembered that a change in the product number will, in many cases, require extensive changes to documents in the head office, regional organizations and at customers. The product number should therefore be retained if the product is fully replaceable with respect to functional and operating characteristics, reliability, installation conditions and interfaces (e.g. electrical connections). If any design changes affect the spare parts service of the product, the MLFB can still remain unchanged. If necessary, production numbers according or serial numbers will enable the function status or product status to be recognized or derived. For further details, please also refer to SN 10370 "Products and technical documents, exchangeability and condition".
3.4. Reuse of product numbers that have become free The responsible parties according to Section 1.4 decide on the reuse of a product number. Prerequisites are: The manufacture of the previous product has been discontinued everywhere (also construction under license abroad) Stocks have been used up The normal period for stocking spare parts has expired 10 years must have passed since the MLFB has become free.
3.5. Numbers parallel to the MLFB In addition to the MLFB, the international article numbers (EAN; see also SN 01090-1) and the Universal Product Code (UPC; see also SN 01090-2) are permitted as well as the product-ID numbering systems which are generally required by external customers.
Basics
B
3. Principles for etablishing the MLFB 3.1. General Technical criteria are decisive when assigning the product features and their characteristics to the data positions of the MLFB scheme. The function of a product is the prime consideration when defining the MLFB. The technical characteristics and their attributes in the catalog correspond to the ranking of the criteria in the data positions of the MLFB (4.1). If possible, the data particularly decisive for the price should also be coded as far as possible at the front of the MLFB. Any aspects which may be subject to change (e.g. organizational) must not be taking into account. The manufacturing plant does not form part of the product number. SN 37040 applies to the identification of the manufacturing plant on products. The product number must satisfy the requirements of personal handling and electronic data processing. The unambiguity and uniformity of the product numbers and the reserve available for new products are monitored centrally by the central working group ZAG MLFB. For these reasons, no department may itself define or change any product numbers. In the event of faults, it must be expected that any MLFBs which have not been agreed upon will be changed!
3.2. MLFB for products manufactured abroad Products which are manufactured abroad by a regional company, constructed under license or purchased from another vendor are assigned a product number according to the same rules as the original Siemens products. The following points apply in addition.
3.2.1. Characters reserved until now The characters reserved until now: 0 at data position 4 Y at data position 9 and Order codes I.. are released for normal use since 01.06.2006
The appointed MLFBs with these chareacters until now remains valid furthermore.
3.2.2. Identification of manufacturing plant The manufacturing plant is not coded in the product number in the case of products manufactured abroad either, but is identified on the rating plate or product label in accordance with SN 37040.
3.3. Product numbers in the case of changed products If a product is changed, the responsible parties referred to in Section 1.4 will check whether a new product number has to be defined or whether the previous number can be retained. It should be remembered that a change in the product number will, in many cases, require extensive changes to documents in the head office, regional organizations and at customers. The product number should therefore be retained if the product is fully replaceable with respect to functional and operating characteristics, reliability, installation conditions and interfaces (e.g. electrical connections). If any design changes affect the spare parts service of the product, the MLFB can still remain unchanged. If necessary, production numbers according or serial numbers will enable the function status or product status to be recognized or derived. For further details, please also refer to SN 10370 "Products and technical documents, exchangeability and condition".
3.4. Reuse of product numbers that have become free The responsible parties according to Section 1.4 decide on the reuse of a product number. Prerequisites are: The manufacture of the previous product has been discontinued everywhere (also construction under license abroad) Stocks have been used up The normal period for stocking spare parts has expired 10 years must have passed since the MLFB has become free.
3.5. Numbers parallel to the MLFB In addition to the MLFB, the international article numbers (EAN; see also SN 01090-1) and the Universal Product Code (UPC; see also SN 01090-2) are permitted as well as the product-ID numbering systems which are generally required by external customers.
Basics
B
3. Principles for etablishing the MLFB 3.1. General Technical criteria are decisive when assigning the product features and their characteristics to the data positions of the MLFB scheme. The function of a product is the prime consideration when defining the MLFB. The technical characteristics and their attributes in the catalog correspond to the ranking of the criteria in the data positions of the MLFB (4.1). If possible, the data particularly decisive for the price should also be coded as far as possible at the front of the MLFB. Any aspects which may be subject to change (e.g. organizational) must not be taking into account. The manufacturing plant does not form part of the product number. SN 37040 applies to the identification of the manufacturing plant on products. The product number must satisfy the requirements of personal handling and electronic data processing. The unambiguity and uniformity of the product numbers and the reserve available for new products are monitored centrally by the central working group ZAG MLFB. For these reasons, no department may itself define or change any product numbers. In the event of faults, it must be expected that any MLFBs which have not been agreed upon will be changed!
3.2. MLFB for products manufactured abroad Products which are manufactured abroad by a regional company, constructed under license or purchased from another vendor are assigned a product number according to the same rules as the original Siemens products. The following points apply in addition.
3.2.1. Characters reserved until now The characters reserved until now: 0 at data position 4 Y at data position 9 and Order codes I.. are released for normal use since 01.06.2006
The appointed MLFBs with these chareacters until now remains valid furthermore.
3.2.2. Identification of manufacturing plant The manufacturing plant is not coded in the product number in the case of products manufactured abroad either, but is identified on the rating plate or product label in accordance with SN 37040.
3.3. Product numbers in the case of changed products If a product is changed, the responsible parties referred to in Section 1.4 will check whether a new product number has to be defined or whether the previous number can be retained. It should be remembered that a change in the product number will, in many cases, require extensive changes to documents in the head office, regional organizations and at customers. The product number should therefore be retained if the product is fully replaceable with respect to functional and operating characteristics, reliability, installation conditions and interfaces (e.g. electrical connections). If any design changes affect the spare parts service of the product, the MLFB can still remain unchanged. If necessary, production numbers according or serial numbers will enable the function status or product status to be recognized or derived. For further details, please also refer to SN 10370 "Products and technical documents, exchangeability and condition".
3.4. Reuse of product numbers that have become free The responsible parties according to Section 1.4 decide on the reuse of a product number. Prerequisites are: The manufacture of the previous product has been discontinued everywhere (also construction under license abroad) Stocks have been used up The normal period for stocking spare parts has expired 10 years must have passed since the MLFB has become free.
3.5. Numbers parallel to the MLFB In addition to the MLFB, the international article numbers (EAN; see also SN 01090-1) and the Universal Product Code (UPC; see also SN 01090-2) are permitted as well as the product-ID numbering systems which are generally required by external customers.
MLFB manual 2011 9 Basics
B 4. Issuance and introduction of the MLFBs 4.1. System for assigning the MLFB The MLFB should be formed using a high degree of classification in conformance with the ranking of selected technical data, characteristics and attributes. The criteria decisive for the price should be coded as far as possible at the front of the MLFB. A classified structure means that the individual data positions are allocated certain product characteristics and attributes (basic technical data) in the sequence of their significance. When transposing the information to the MLFB positions, the number of available characters (numerical/alpha positions) must be taken into account in the existing number of versions. The significance of supplementary data positions within the MLFB must not contradict the meaning of previous data positions. Clear presentation in the catalog, in particular with respect to breakdown into the MLFB group and supplements, must be possible. The supplements are show in the sequence of data positions without any overlapping.
4.2. Assignment of the MLFBs taking into consideration SAP, FDB and catalogs With the introduction of SAP, the so-called "Master material data" (e.g. for marketable products, modules, parts) can be recorded in SAP, i.e. adoption and updating of these data are carried out in SAP. Classifications are saved in SAP as configurable material (KMAT). The product master data is divided into core and supplemental sets. To ensure the uniform flow of SAP material master data and PMD and their depiction in catalogs, close cooperation of the responsible centers is required as early as the product development phase and right up to the release to sales.
4.3. Assignment time of MLFB The MLFB should be assigned in good time by the responsible departments (see Section 1.4), or in coordination with them, i.e. already during the development phase (development agreement) of the product.
4.4. MLFB for products of modular design An MLFB must be defined as a product number for every listed module. Racks or cabinets fitted with modules (constructional units) and combined module packages can be assigned their own MLFB in order to simplify ordering and processing.
4.5. MLFB for accessories and spare parts In many main groups, the letter "X" is assigned at data position 3 for accessories, and the letter "Y" for spare parts. Wherever the existing reserve and selection logic permit, accessories and spare parts should be numbered in these subgroups. Otherwise the number "9" can be used for accessories and spare parts at the data position directly following the type designation (usually at the 5th position).
4.6. MLFB for Instruction Manuals and technical documents Instruction Manuals must be numbered taking into account the numbering system (MLFB or SSN) to be applied. In the exA&D Group, this applies in part to all technical documents to be supplied, e.g. Instruction Manuals, equipment manuals, programming instructions etc. The Order No. is determined within the context of the product numbering system.
4.7. MLFB for special versions An unambiguous order designation is required for electronic data processing of frequently ordered special versions of listed products (e.g. customer versions). It is then often useful to retain the product number of the normal version, and to use an Order code in accordance with Section 2.3 to identify the deviation.
4.8. Introduction of defined MLFB When an MLFB is defined, the participating departments agree on its date of introduction. The date depends on: Availability of the products in PMD (release for sale, release for delivery) Production of catalog/price list Production of Instruction Manuals
MLFB manual 2011 10 Basics
B 5. Application 5.1. Product number When ordering, it is obligatory to specify the product number (full identification, also with additional ordering data according to Section 2 if applicable). The recipient of the order is not obliged to additionally check the product description for conformance with the product number.
5.2. Product description The product description should lead to the product number (= Order No.) of the desired product. It consists of one or more blocks with a maximum of 31 characters each. In the case of products which have several versions, for which the MLFB has been defined as a main group and supplementary blocks, the product description is broken down into the "main group text" and texts for the supplementary positions. A maximum of 20 lines can be used for each block, but may be restricted by certain DP procedures. The product description shall be applicable for price lists, quotations, orders, order acknowledgments, dispatch documents, invoices, parts lists and technical documentation.
5.3. Standardization of product numbers The conventions regarding the notation/storage form of the product number must be strictly observed for electronic handling of orders and access to databases. This can be assured by using the NORM standardization program. Further details can be found in the Siemens standard SN 01080.
5.4. Functional and constructional units without own product number Functional and constructional units may exist for which it is inappropriate to assign a product number (e.g. one-off custom-specific configuration) or not feasible because of the complexity (e.g. plant, system). Constructional units of this kind can be described and offered in catalogs, but it is not possible to define a separate or combined Order No. For ordering purposes, the MLFBs of the individual assemblies constituting the requested (or planned) constructional unit must be specified item by item. Conventions have been agreed upon to link up the individual items to permit the ordering, dispatch and accounting of such constructional units. These are published in the Siemens Logistics Lexicon (SLL) by CSP Mch: Central regulations and information Electronic business handling - Orders Identification for supply coherence.
6. PMD
I IA/DT, I BT LV, I IS and Energy (in part) manage their products in PMD (Product Master Data). Product master data (product no., product description, prices, ORG-ID, etc.) are saved in PMD, which are made available to the user processes such as bids, configuration procedures, order handling processes and to the PMI Corporate Service and for preparing the Mall, CA01 and PMD on PC. The product master data encompass commercial and technical information. The PMD responsibilities were regulated in the A&D BV circular dated 28 Oct. 2005. The technical responsibility lies with PMD Central, department I IA CE ITS FT 1. The process support lies with I IA IT PLM 2
MLFB manual 2011 11 Basics
B 7. MLFB use from former Siemens Sections
Bruker AXS GmbH stliche Rheinbrckenstr. 50 D-76187 Karlsruhe Contact person: Mr. Kolodziej
Changes Date Adjustment of the department designations 08.12.2008 Elimination of an error 12.01.2009 New Sub groups of 3AM and 3TM were added 02.02.2009 New Sub group 2GP1 17.04.2009 Adjustment of the department designations 05.10.2009 New Sub group 3AV, change of the members of ZAG MLFB 30.11.2009 New Sub group 3ZW1 18.12.2009 New Sub groups of 3ZY1 and 6FE1 were added, change of the members of ZAG MLFB 17.05.2010 New Sub group 7SC8 10.09.2010 New Sub groups 4KT1 and 8EM1 24.09.2010 New Sub group 9LD1 08.12.2010 New Sub group 3SK1 21.01.2011 New Sub groups of 1CA1, 1CS1, 6VC1 und 6VC2 were added 23.02.2011 New Sub group 3RM1 31.03.2011
MLFB manual 2011 13 1 Main group A Miniature motors (special design) B Low-power motors and miniature motors(special design) C Electrical machines for electric mobility D Three-phase synchronous machines E Single-phase synchronous machines F Synchronous machines G D.C. machines, internally-cooled H D.C. machines, surface-cooled and closed-circuit-cooled J D.C. machines K Pulsating current and A..C. commutator machines L Three-phase asynchronous machines, surface-cooled M Three-phase asynchronous machines, surface-cooled, EEx N P Three-phase asynchronous machines, surface-cooled for special applications Q R Three-phase asynchronous machines, internally-cooled and closed-circuit-cooled S Three-phase asynchronous machines, internally-cooled and closed-circuit-cooled, EEx and for special applications T Asynchronous machines U Converter motors in single-housing design V Generating sets W X Machine parts and accessories Y Z Superordinate group 1 Electrical machines MLFB manual 2011 14 1 A Sub group Catalog Product- responsibility A B D.C. motors, coreless armature formerly automotive engineering C D.C. motors, iron-cored armature formerly automotive engineering D D.C. motors, collectorless, internal rotor formerly automotive engineering E F Single-phase synchronous motors, split-pole, formerly automotive external rotor engineering G H Single-phase synchronous motors, hysteresis rotor, formerly automotive split-pole, high-speed engineering J Single-phase synchronous motors, hysteresis rotor, formerly automotive auxiliary phase engineering K L Single-phase synchronous motors, permanent formerly automotive magnet rotor engineering M Synchronized asynchronous motors formerly automotive engineering N D.C. motors, coreless armature, formerly automotive disk rotors engineering P Q Stepper motors, single-stranded formerly automotive engineering R Asynchronous, split-pole motors formerly automotive engineering S T U Asynchronous, split-pole motors, low rotor torque formerly automotive engineering V Asynchronous motors, auxiliary phase formerly automotive engineering W Asynchronous motoros, special design formerly automotive engineering X Accessories formerly automotive engineering Y Z Main group 1A Miniature motors (special design) MLFB manual 2011 15 1 B Sub group Catalog Product- responsibility A Commutator motors with exciter winding PV BSHG Radial fan nash_elmo Industries B D.C. motors with permanent excitation formerly automotive engineering C Claw-pole stepper motors formerly automotive engineering D E Single-phase asynchronous motors with formerly automotive running capacitor, internal rotor engineering F Single-phase asynchronous motors with running and formerly automotive starting capacitor engineering G Single-phase asynchronous motors with starting capacitor H Single-phase asynchronous motors with formerly automotive resistance-start motor engineering J Single-phase asynchronous motors with formerly automotive short-circuit auxiliary phase engineering K Single-phase asynchronous motors, pole-reversible L Single-phase asynchronous motors with running formerly automotive capacitor, external rotor engineering M Single-phase asynchronous motors with formerly automotive split-pole auxiliary phase engineering N P Collectorless D.C. motors, external rotor formerly automotive engineering Q Three-phase asynchronous motors, external rotor formerly automotive engineering R Three-phase asynchronous motors, internal rotor formerly automotive engineering S Stepper motors with multi-phase stator winding formerly automotive engineering T U V Double-armature motors formerly automotive engineering W X Y Synchronous motors formerly automotive engineering Z Other motors formerly automotive engineering Main group 1B Low-power motors and miniature motors(special design) MLFB manual 2011 16 1C Sub group Catalog Product- responsibility A see following pages for released 4-digit subgroups B C D E F G H J K L M N P Q R S see following pages for released 4-digit subgroups T U V W X Y Z Main group 1C Electrical machines for electric mobility MLFB manual 2011 17 1CA Sub group Catalog Product- responsibility 0 1 Induction motors, main drives up to 150 kW I DT EC 2 3 4 5 6 7 8 9 Main group 1C Electrical machines for electric mobility MLFB manual 2011 18 1CS Sub group Catalog Product- responsibility 0 1 Synchronous motors, main drives up to 150 kW I DT EC 2 3 4 5 6 7 8 9 Main group 1C Electrical machines for electric mobility MLFB manual 2011 19 1 D Sub group Catalog Product- responsibility A Non-salient pole motors, rpm > 3600/min I DT LD B Traction machines I DT LD C Reactive-power machines I DT LD D Non-salient pole motors, H module, open I DT LD cooling system; basic design E Non-salient pole motors, H module, air-water cooler I DT LD F Non-salient pole motors, H module, air-air cooler I DT LD G Non-salient pole motors, other I DT LD H Salient-pole generators for water-turbine I DT LD drive J Non-salient pole motors, H module, open I DT LD cooling system; weather-protected K Salient-pole generators for piston machine I DT LD drive L Motors, basic design standard I DT LD M Salient-pole motors, other I DT LD N Salient-pole motors for tube mills I DT LD P Permanet magnet exciting motors I DT LD Q Non-salient pole motors for rolling mills I DT LD R Motors, Ex protection, standard I DT LD S Salient-pole generators, other I DT LD T Non-salient pole generators I DT LD U Generators, standard I ST LD V Shaft generators Voith Siemens Hydro, Power Generation Gmbh&CO.KG W Non-salient pole generators I DT LD X Non-salient pole motors I DT LD Y Salient-pole generators I DT LD Z Salient-pole motors I DT LD Main group 1D Three-phase synchronous machines MLFB manual 2011 20 1 E Sub group Catalog Product- responsibility A Non-salient pole motors, rpm > 3600/min I DT LD B Traction machines I MO C Reactive-power machines Voith Siemens Hydro, Power Generation I IS D E F G Non-salient pole motors, other I DT LD H Salient-pole generators for water-turbine drive I DT LD J K Salient-pole generators for piston machine drive I DT LD L M Salient-pole motors, other I DT LD N Salient-pole motors for tube mills I DT LD P Permanent magnet exciting motors I DT LD Q Non-salient pole motors for rolling mills I DT LD R S Salient-pole generators, other I DT LD T Non-salient pole generators I DT LD U V W X Y Z Main group 1E Single-phase synchronous machines MLFB manual 2011 21 1 F Sub group Catalog Product- responsibility A Machines with sliprings, open cooling system M 3 B Machines with sliprings, open cooling system M 3 I DT SD with built-in or add-on KS unit C Machines, basic design, open cooling system M 3 D E Permanently excited main-spindle drives NC 60.1 I DT MC (synchronous machines) F Machines with add-on or built-in fans G Rectifiers H Basic design, surface-cooled I DT SD J Machines with air/water cooler E K Compact, converter-fed synchronous motors NC 60.1 I DT MC
L Stepper motors NC 60.1 I DT MC M Mid-frequency machines N Three-phase synchronous linear motors NC 60.1 I DT MC P Reluctance motors, surface-cooled I DT LD Q Machines with air/air cooler E R Marine machines, open or closed cooling system, with air/water cooler S Permanent magnet machines EEx e II, NC 60.1 I DT MC Brushless synchronous machines EEx e II T Three-phase feed motors and robot drives NC 60.1 I DT MC U Permanent magnet machines DA 12 I DT LD Permanently excited synchronous motors DA 48 V Automobile synchronous machines I DT LD, I IS 1FV2 self-clocked synchronous machines W Various synchronous machines I DT LD I DT MC X Y Z Main group 1F Synchronous machines MLFB manual 2011 22 1 G Sub group Catalog Product- responsibility A Basic design, self-cooling DA12 I DT LD B Lifting gear motors, self-cooling H2 C Compact drives H2 D Lifting gear motors, separately cooled with H2 radial built-on fan E F Machines with built-on or built-in fan DA12 I DT LD G Machines with top-mounted standard fan DA12 I DT LD H Machines fpr pipe connection and separately DA12 I DT LD driven fan J Geraless elevator motors K L D.C. motors with axial built-on compact fan DA12 I DT LD M D.C. motors degree of protection EEx p I DT LD N Motors for machine tools, non-drive end prepared I DT LD for axial or radial attachment of a separate fan P Pendulum machines I DT LD Q R Marine machines, internally cooled, self-cooling or separate fan S Servo motors I DT LD I DT MC T U Permanent magnet machines I DT LD V Special machines I DT LD W Rolling mill motors (mill series) X Y Z Main group 1G D.C. machines, internally-cooled MLFB manual 2011 23 1 H Sub group Catalog Product- responsibility A Basic design I DT LD B Lifting geart EWN: self-cooled H 2
C Design without external fan (self-cooling) DA 12 I DT LD D Lifting gear motors separately cooled with top-mounted H 2 air/air cooler E F Design with built-on, top-mounted or built-in DA 12 I DT LD separate fan G H J K L Design with top-mounted air/air cooler and self-cooling I DT LD
M N P Q Design with top-mounted air/air cooler and DA 12 I DT LD separate cooling R Marine machines, closed-circuit-cooled with air/air or air/water cooler S Design with top-mounted air/water cooler DA 12 I DT LD T D.C. machines degree of protection EEx p I DT LD U Permanent magnet machines DA 12 I DT MC SD 85 V Load generators I DT LD W X Y Spare parts SD 85 I DT MC Z Main group 1H D.C. machines, surface-cooled and closed-circuit-cooled NMA: self-cooled MLFB manual 2011 24 1 J Sub group Catalog Product- responsibility A B Traction machines I MO C D Exciters, compensated I DT LD E Exciters, uncompensated I DT LD F Conveyor motors G Rectifiers I DT LD, E H J K L M N P Special machines, compensated, e.g. Ex protection I DT LD Q Special machines, uncompensated, e.g. I DT LD Ex protection R S Control generators I DT LD T U Unipolar machines V W Roller motors X Y Z Main group 1J D.C. machines MLFB manual 2011 25 1 K Sub group Catalog Product- responsibility A B Traction motors I MO C D Three-phase shunt motors, internally cooled, I DT LD self-cooled E Three-phase shunt motors, internally cooled, I DT LD with built-in separate fan F Three-phase shunt motors, internally cooled, I DT LD with built-on separate fan G Three-phase shunt motors, I DT LD surface-cooled, self-cooled H Three-phase shunt motors, I DT LD surface-cooled with built-on separate fan J Three-phase shunt motors, internally cooled, I DT LD separately cooled, coolant air fed via pipe connection K L M N P Q R S T U Frequency converter, internally cooled H 10 I DT MC V W X Accessories Y Spare parts H 10 Z Main group 1K Pulsating current and A..C. commutator machines MLFB manual 2011 26 1 L Sub group Catalog Product- responsibility A Basic design M 11, M 19, I DT LD M 26, M 29 B Lifting gear motors H 10 C Brake motors I DT LD D Lifting gear brake motors I DT MC E Low voltage motors, general characters I DT LD F Motors for single-phase and two-phase operation M 19 I DT LD G Motors for low voltage, iron M 11 I DT LD H Motors for diving pumps, liquid-cooled motors I DT LD
J K Generalized-phase-controlled motors (SIEMOTRAS-drives) L Motors with additional internal cooling M 19, M 26, I DT LD (H-compact), IP 23 M 29 M 1) N Polyphase magnets I DT LD P Basic design without fan (self-cooling) M 19 I DT LD Q Basic design without fan (self-cooling) R Motors with additional internal cooling (H-compact), IP 23 S Basic design M 19, M 25 I DT LD T Lifting gear motors H 2 I DT MC U Brake motors I DT LD V Lifting gear brake motors H2 I DT MC W Lifting gear motors in steel H2 X Y Spare parts H 2, H 10, M 11, I DT LD M 19 Z 1) for new use closed since 01.12.1996 Main group 1L Three-phase asynchronous machines, surface-cooled MLFB manual 2011 27 1 M Sub group Catalog Product- responsibility A Basic design M 11, M 26, I DT SD, I DT LD M 29 B Motors for special environment conditions I DT SD C D E Low voltage, basic design M11 I DT SD F Motors with integral fan I DT SD G Pressurized motors, squirrel-cage rotor M 26 I DT LD H Pressurized motors, slipring rotor I DT LD J Basic design M 11, M19 I DT SD, I DT LD K Mining motors, air-cooled, for winding systems L Low voltage, basic design M 11 I DT SD M Basic design, underground, water-cooled N P Fan motors for pipe installation, motors without I DT SD integral fan Q Basic design, underground, air-cooled R Special motors, underground, air and water-cooled S Basic design I DT LD T U V W X Y Z Main group 1M Three-phase asynchronous machines, surface-cooled, EEx MLFB manual 2011 28 1 P Sub group Catalog Product- responsibility A Compact, converter-fed asynchronous motors in DA 65 I DT MC degree of protection IP 65 B Deck motors C Special motors I DT SD D Loom motors E Spinning-spindle motors F Various motors H 3 I DT LD G H Frequency-driven motors with separate fan NC 60.1 I DT MC, I DT LD for machine tool main spindle drives J K Integrated motors I DT LD, I DT SD L Compact, converter-fed DA65 I DT MC asynchronous motors in degree of protection IP 23 M Hollow-shaft motors (foreign manufacture) I DT MC N Motors with additional internal cooling I DT LD H compact P Fan motors for pipe installation without integral fan M 19 I DT SD Q Separately cooled motors with built-on fan M 19 I DT LD
R Friction-drum motors, roller motors S Loher motors I DT LD T U V Automotive electric motors formerly automotive 1PV3 rotary resolver (C31 synchro) engineering, I DT MC W X Y Z Main group 1P Three-phase asynchronous machines, surface-cooled for special applications MLFB manual 2011 29 1 R Sub group Catalog Product- responsibility A Basic design, open cooling system M 27, M 29 I DT LD B Lifting gear motors IP 23 C Lifting-gear motors IP R 56 for shipboard cranes D Three-phase motors with extruded housing E F Motors for one- and two-phase operation I DT LD G H J K L M N with air/water cooler M 27, M 29 I DT LD P Weather-protected design, open cooling system I DT LD Q with air/air cooler M 27 I DT LD R with air/air cooler M 27 I DT LD S Basic design, open cooling system M 27 I DT LD T Lifting gear motors U with air/water cooler M 27 I DT LD V Lifting gear brake motors W Weather-protected design, open cooling system I DT LD X Y Z Main group 1R Three-phase asynchronous machines, internally-cooled and closed-circuit-cooled MLFB manual 2011 30 1 S Sub group Catalog Product- responsibility A Basic design, open cooling system, EExe I DT LD B with air/air cooler, EEx p M 27 I DT LD C Basic design, open cooling system, Exn D Weather-protected design, I DT LD open cooling system E F G with air/air cooler, Exn I DT LD H Centrifuge motors IP 21 I IS J with air/air cooler, EExe I DT LD K Inegral motors L with air/water cooler, Exn I DT LD M Hollow shaft motors (1SM0) foreign manuf., Single-armature motors (1SM3) N with air/water cooler, EExe I DT LD P Pendulum machines IP 20, KL or SL I DT LD Q with air/water cooler, EEx p M 27 I DT LD R with air/air cooler, EEx p I DT LD S Basic design EEx e I/EEx d I, IP 23/IP 44 T with air/water cooling, EEx p I DT LD U Motors EEx e I/EEx d I, IP 44/IP 44 with top-mounted air/water cooler and integral fan V Motors EEx e I/EEx d I, IP 44/IP 44 with top-mounted air/water cooler and separate fan W Three-phase transformers X Y Z Main group 1S Three-phase asynchronous machines, internally-cooledand closed-circuit-cooled, EEx and for special applications MLFB manual 2011 31 1 T Sub group Catalog Product- responsibility A Squirrel cage motors, rpm >3600/min I DT LD B Traction machines I MO C Squirrel cage motors, other I DT LD D Motors, Ex protection I DT LD E Squirrel cage motors, pole-changing I DT LD F Basic design, standard M 28 I DT LD G Basic design, standard, pole-changing I DT LD
H Motors, standard, Ex protection I DT LD J Integral motors I DT LD K Slip clutches L M Slipring rotor motors, other I DT LD N Motors, Ex protection I DT LD P Rectifier-fed machines M 29 I DT LD Q Squirrel cage motors for mills R S Synchronized asynchronous machines I DT LD T Basic design, standard I DT LD U Motors, standard, Ex protection I DT LD V Slipring rotor motors I DT LD special design (three-phase transformers or similar) W Slipring rotor motors I DT LD h-moflex, subsynchronous cascade X Slipring rotor motors without BAV I DT LD Y Slipring rotor motors with BAV I DT LD Z Squirrel cage machines I DT LD Main group 1T Asynchronous machines MLFB manual 2011 32 1 U Sub group Catalog Product- responsibility A Motors with top-mounted (integrated) DA 64 I DT MC COMBI MASTER frequency converter B C Internally cooled, degree of protection IP R 44 D E F G H J Closed-circuit-cooled with built-on air/water cooler, degree of protection IP 44 K L M N P Q R S Internally-cooled three-phase/three-phase (asynchronous/synchronous) T Internally-cooled, three-phase/d.c. U V W X Y Z Main group 1U Converter motors in single-housing design MLFB manual 2011 33 1 V Sub group Catalog Product- responsibility A Basic design without supporting frame B Basic design with supporting frame C Basic design with supporting frame and built-on switching cubicle D Design with supporting frame and built-on switching cubicle with enclosure E Design with supporting frame and built-on switching cubicle with enclosure and truck F G H J K L Special equipment M N P Q R S T U V W Wind energy converter E X Accessories Y Z Main group 1V Generating sets MLFB manual 2011 34 1 X Sub group Catalog Product- responsibility A Terminal boxes M 2 I DT LD B Terminal boxes M 1, M 2, DA 12, I DT MC, I DT SD, I DT LD C Terminal boxes (flameproof bushing) M 11, M 2 I DT SD, I DT LD D Terminal boxes M 2 I DT LD E Terminal boxes I DT LD F Terminal boxes I DT LD G H J K L M Slipring enclosures, flameproof N P Machine accessories M 1, M 2 I DT MD Q
1) R Baseplates M 11 I DT SD 1) S Lubricants M 11 I DT SD T U V W X Small accessories and devices I DT SD Y Universal parts (identical parts) I DT SD Z 1) for new use closed since 01.01.1998 Main group 1X Machine parts and accessories MLFB manual 2011 35 2 Main group A Liquid pumps and compressors B Vacuum pumps and compressors, equipment ELMO-F, ELMO-G, ELMO-L systems, gas ejector C Ventilators, ring-type blower ELMO-C system D E Special machines, tools F G Various products H Domestic electrical products J K Complete drives with electric motors L Power transmission elements M Armatures and general equipment N Heating and air conditioning products P Q R Heating and air conditioning products S Actuators T U V W Heat pumps, heat meters X Service Y Z Superordinate group 2 Products with electric motor drives, RF heating and airconditioning products MLFB manual 2011 36 2 A Sub group Catalog Product- responsibility A Self-priming pumps nash_elmo Industries GmbH B Submersible pumps nash_elmo Industries GmbH C D Self-priming liquid pumps nash_elmo Industries GmbH E ELMO-F, single-impeller design nash_elmo Industries GmbH manufactured in China F Drainage pumps nash_elmo Industries GmbH G H J Domestic machines, domestic systems nash_elmo Industries GmbH K L Alkali pumps I IS M Dishwasher pumps and centrifugal pumps N Centrifugal pumps P Q R Glandless oil circulating pumps nash_elmo Industries GmbH S Oil supply plants I DT LD T U V ELMO-F, single-impeller design, mono-block nash_elmo Industries GmbH construction Manufacturing in China (SVPC China) W X Accessories nash_elmo Industries GmbH Y Z Main group 2A Liquid pumps and compressors MLFB manual 2011 37 2 B Sub group Catalog Product- responsibility A ELMO-F, single-impeller design with end shield nash_elmo Industries GmbH B ELMO-F, single-impeller design with control nash_elmo Industries GmbH shield C ELMO-G, manufactured in Columbia nash_elmo Industries GmbH D ELMO-F, single-impeller design, lightweight nash_elmo Industries GmbH E ELMO-F, single-impeller design with end shield P F nash_elmo Industries GmbH (vertex at top); also as aggregates F ELMO-F, double-stage vacuum pumps nash_elmo Industries GmbH G ELMO-F, double-stage compressors P F nash_elmo Industries GmbH H ELMO-G, total pressure difference to 900 mbar P G nash_elmo Industries GmbH ELMO-G S (with variable frequency drive) J ELMO-G, high-speed pumps, controllable nash_elmo Industries GmbH K ELMO-F, double-acting compressors P F nash_elmo Industries GmbH L ELMO-L, vacuum pumps air/water-cooled P L nash_elmo Industries GmbH M N P Gas ejectors P F nash_elmo Industries GmbH Q R ELMO-R, high-speed pumps, high-pressure nash_elmo Industries GmbH radial-flow blower S Vacuum pump stands nash_elmo Industries GmbH T U ELMO-aggregates nash_elmo Industries GmbH V ELMO-F, single-impeller design, unit construction P F nash_elmo Industries GmbH W ELMO Package Units (closed-circuit vacuum nash_elmo Industries GmbH pumps/compressors) MeC Bln X Accessories P F, P G nash_elmo Industries GmbH Y Spare parts P E, P F, P G nash_elmo Industries GmbH Z Main group 2B Vacuum pumps and compressors, equipment ELMO-F, ELMO-G, ELMO-L systems, gas ejector MLFB manual 2011 38 2 C Sub group Catalog Product- responsibility A Small ventilators B Wall and window ventilators i-center C Betz ventilators and similar V I IA CE D E F Radial ventilators (electric blower) V, P C I IA CE G H ELMO-G compressors and vacuum pumps (to 9.87) P C nash_elmo Industries GmbH ELMO-C ring blower (from 10.95) J K Semiaxial ventilators V I IA CE, I DT LD L Low-pressure axial ventilators (K profile) I IA CE M N P Q Medium-pressure axial ventilators to 60% boss ratio V I IA CE
R S Ventilators in special design I IA CE for transport systems T Ventilators in special design I IA CE for stationary systems (e.g. transformers) U V Fitted ventilator equipment sets W Installed/fitted ventilator equipment sets DA 12, M 1 I DT SD, I DT LD X Accessories V, P C I IA CE Y Spare parts I IA CE Z Main group 2C Ventilators, ring-type blower ELMO-C system MLFB manual 2011 39 2 E Sub group Catalog Product- responsibility A B Metal parts for machines and devices nash_elmo Industries GmbH C D Commutator grinding devices, rotary grinders see Main group 1J E F Commutator grinding devices, fixed grinders see Main group 1J G H J K L M N P Q Measuring equipment I IA CE, I BT LV R Laser-head housing S Special machines I IA CE, I BT LV T U V Devices I IA CE, I BT LV W Tools I IA CE, I BT LV X Y Z Main group 2E Special machines, tools MLFB manual 2011 40 2 G Sub group Catalog Product- responsibility A Electrotechnical devices and equipments EA for training B C D E F Video devices and equipment ST 50 I IA AS G H J K L M N P Dimerization software for the electrical energy I BT LV distribution Q R Handling equipment for machine tools S T U V W X Y Z Main group 2G Various products MLFB manual 2011 41 2GP Sub group Catalog Product- responsibility 0 1 SIMARIS design, SIMARIS project I BT LV and SIMARIS curves in 2 3 4 5 6 7 8 9 Sub group 2GP Dimerization software for the electrical energy distribution MLFB manual 2011 42 2 H Sub group Catalog Product- responsibility A Solenoid valves K 3675 to K 3678 I IA CE, I BT LV B Solenoid valves K 3679 I IA CE, I BT LV C Solenoid valves for large flow volumes I IA CE, I BT LV D E F G H J K Program control devices I IA CE, I BT LV L M N P Pushbutton strips I IA CE, I BT LV Q R Pilot switches and actuators I IA CE, I BT LV S T Safety equipment I IA CE, I BT LV U V W X Components, accessories BSH GmbH Kund.-Betr.-Center Y Spare parts I IA CE, I BT LV Z Main group 2H Domestic electrical products MLFB manual 2011 43 2 K Sub group Catalog Product- responsibility A Standard D.C. Drives I DT LD B C D E F Complete drives for vehicles I DT LD G Complete drives with electromotor M15 I DT MD H Gear motors I DT SD J Gear motors D 87 I DT MD K L M N P Q R S T U V W D.C. drives for machine tools X Y Z Main group 2K Complete drives with electric motors MLFB manual 2011 44 2 L Sub group Catalog Product- responsibility A B Vehicle drives C Clutches MD10 I DT MD D Slipring toothed clutches and ZF-Friedrichshafen Slipring single-disk clutches E Slipringless clutches ZF-Friedrichshafen, BF Milano F Mechanical clutches M 11, P F I DT LD, nash_elmo Industries GmbH G Fitted gearboxes, manual-shift gearboxes M 14, DA 12 N, I DT MC NC 60.1 H Freestanding gearboxes J K Pneumatic and hydraulic clutches, ZF-Friedrichshafen, brakes and clutch-brake combinations BF-Milano L Brake ventilation devices I DT MC M Mechanical brakes I DT LD, I DT MC N Electromechanical brakes and hydraulic brake and positioning systems P Brakes MD20 I DT MD Q R S T U V W Whirlpool brakes H 2 X Accessories I DT MC, I DT MD Y Z Main group 2L Power transmission elements MLFB manual 2011 45 2 M Sub group Catalog Product- responsibility A B C D E F Centrifugal switches G H J K L M N P Q R S Inertia flywheels T U V W X Y Z Main group 2M Armatures and general equipment MLFB manual 2011 46 2 N Sub group Catalog Product- responsibility A Air warming devices B Hot air devices V 12 nash_elmo Industries GmbH I IA CE, I BT LV C Convector heaters (direct heaters) Glen Dimplex D Room heaters, direct heaters, Glen Dimplex Infrared radiators E F PERMATHERM electric storage heaters Glen Dimplex and accessories G PERMATHERM electric storage heaters Glen Dimplex H J K Air conditioning devices and accessories Glen Dimplex L TECLINE warm water devices Glen Dimplex M N P Electrical heating elements Q Partial air conditioning devices, Glen Dimplex air humidifiers, filters, metal parts, housings R Room temperature thermostats, charge control Glen Dimplex devices, frost monitors, control devices I MO S Components for heating swimming pools T Area heat conductors U Components for central heating systems V Electrical storage heaters, static Glen Dimplex W Direct heaters, infrared radiators Glen Dimplex X Y Z Main group 2N Heating and air conditioning products MLFB manual 2011 47 2 R Sub group Catalog Product- responsibility A Components for light water pressure reactors FRAMATOME ANP B Components for light water-boiler reactors FRAMATOME ANP C Components for heavy water pressure reactors FRAMATOME ANP D E F G H J K L M N P Q R S T U V W X Y Z Main group 2R Heating and air conditioning products MLFB manual 2011 48 2 S Sub group Catalog Product- responsibility A Electrical rotary drives MP 35 SIPOS B Electrical linear drives MP 35 SIPOS C Electrical part-turn drives MP 35 SIPOS D Electrical rotary drives with 2 motors E Other actuators (pneumatic, hydraulic) F Supplementary gears (thrust stages) MP 35 SIPOS G H J K L M N P Motor spindle I DT MC Q R S T U V W X Accessories MP 35 SIPOS Y Accessories MP 35 SIPOS Z Main group 2S Actuators MLFB manual 2011 49 2 W Sub group Catalog Product- responsibility A B C D E F G H J K L M N P Heat pumps and accessories Glen Dimplex Q R Closed-loop and open-loop control devices for Glen Dimplex heat pumps, heating systems and meters I BT S T U V W X Y Z Main group 2W Heat pumps, heat meters MLFB manual 2011 50 2 X Sub group Catalog Product- responsibility A B C D E F G H J K L M N P Q R S T U V Service products, components I IS, I O W X Y Z Main group 2X Service MLFB manual 2011 51 3 Main group A Circuit breakers B C Switches, load break switches D Disconnectors and grounding switches E Overvoltage protection devices F Insulators G HH-fuse devices H J K Disconnectors L Control switches M N NH-fuse devices P Starters, actuators, resistor units Q R Electronic low-voltage switch gears S Command- and signal devices T Contactors, contactor combinations U Overload relays, fault current relais, motor protection equipment V Circuit breakers W Open circuit breakers X Y Z Special equipments Superordinate group 3 High voltage device, Low voltage switch technology MLFB manual 2011 52 3 A Sub group Catalog Product- responsibility A B Low-oil indoor circuit breakers C Low-oil indoor circuit breakers, E D MV C block-type drive D Outdoor automatic vacuum recloser E D MV C E Indoor circuit breaker SION E D MV C F Indoor vacuum circuit breakers E D MV C G Indoor vacuum circuit breakers E D MV C H Indoor vacuum circuit breakers HG11, HA 35 E D MV HA 41 J Vacuum circuit breaker module HG 11 E D MV C NX ACT K Indoor vacuum circuit breaker module E D MV C NX ACT3 L M See following pages for released 4-digit subgroups N H 801 low-oil 3-pole circuit breakers E T P High-voltage circuit breakers E T HP to 145 kV Q SF6-blow-out piston switches E T HP R Simple interrupting circuit breakers E T S 3-pole SF6 circuit breakers E T T 3-pole SF6 circuit breakers E T HP U V High-voltage circuit breaker E T HP W X Accessories HG 11 E D MV C Y Spare parts HG 11 E D MV C Z Main group 3A Circuit breakers MLFB manual 2011 53 3AM Sub group Catalog Product- responsibility 0 1 High-voltage circuit breaker E T PS forced triggered sparkgap in parallel with a bypass switch 2 3 4 5 6 7 8 9 Sub group 3AM Circuit breakers MLFB manual 2011 54 3AV Sub group Catalog Product- responsibility 0 1 Single interrupter high-voltage circuit breaker E T HP 2 Double interrupter high-voltage circuit breaker E T HP 3 (still specifying of E T HP) E T HP 4 (still specifying of E T HP) E T HP 5 (still specifying of E T HP) E T HP 6 (still specifying of E T HP) E T HP 7 8 9 Sub group 3AV High-voltage circuit breaker MLFB manual 2011 55 3 C Sub group Catalog Product- responsibility A Indoor load break switches with lateral drive E D MV C B Indoor load break switches with lateral drive E D MV C C Indoor load break switches with central drive E D MV C D Indoor load break switches with lateral drive, E D MV C with dropper E Indoor load break switches with central drive, E D MV C with dropper F Indoor load break switches, swivel support design E D MV C G Indoor vacuum switches HG 12 E D MV C H J Indoor load break switches, three-pole HG 12 E D MV C K L M N P Q R S T U V W Indoor load break switches, three-pole HA 42 E D MV (Manufactured by: F & G) X Accessories HG 11, HG 12 E D MV C Y Spare parts HG 12 E D MV C Z Main group 3C Switches, load break switches MLFB manual 2011 56 3 D Sub group Catalog Product- responsibility A Disconnectors, 1-pole, with shaft HG 11 E D MV C B Disconnectors, 1-pole, without shaft E D MV C C Disconnectors, 3-pole HG 11 E D MV C D Grounding switches, 1-pole HG 11 E D MV C E Grounding switches, 3-pole HG 11 E D MV C F Fault initiating switches, 1-pole E D MV C G Fault initiating switches, 3-pole HA 42 E D MV C H J K L M High-voltage vertical-break disconnectors E T HP N High-voltage break disconnectors E T HP P High-voltage center-break disconnectors, 2 insulators E T HP Q High-voltage center-break disconnectors, 3 insulators E T HP R S High-voltage pantograph disconnectors E T HP T U V W High-voltage grounding switches E T HP X Accessories HG 11 E D MV C Y Spare parts HG 11 E D MV C Z Main group 3D Disconnectors and grounding switches MLFB manual 2011 57 3 E Sub group Catalog Product- responsibility A Valve-type arrester HG 21 E T HP B Surge arrester for train applications HG 21 E T HP C Direct voltage arrester HG 21 E T HP D E Machine arresters and special arresters HG 21 E D MV C F Limiters HG 21 E D MV C/E T HP G Medium-high voltage arresters, lightweight HG 21 E T HP H Medium-high voltage arresters, plug-in HG 21 E D MV C J K Medium-high voltage arresters, heavyweight HG 21 E T HP L Polymer-Overhead line isolators E T HP M High-voltage arresters (silicon carbide arresters) HG 21 E T HP N P High-voltage arresters (metal-oxide arresters) HG 21 E T HP Q High-voltage arresters, plastic compound casing HG 21 E T HP R Overvoltage arrester E T HP S Surge arrester for gas insulated (SF6) switchgears HG 21 E T HP T U V W X Accessories HG 21 E T HP Y Z Main group 3E Overvoltage protection devices MLFB manual 2011 58 3 F Sub group Catalog Product- responsibility A Indoor isolators of cast resin HG 22 E D MV C B C Indoor isolators of porcelain HG 22 E D MV C D E Outdoor isolators of porcelain HG 22, HG 23 E D MV C KPW Red F G H Indoor bushings of cast resin HG 22 E D MV C J K Indoor bushings of porcelain E T HP (without capacitor bushing) L Polymer-Overhead line isolator E T HP AR M Outdoor bushings of porcelain HG 22 E D MV C (without capacitor bushing) N P Outdoor bushings of cast resin Q R Overhead line isolators HG 23 KPW Red S T U V W X Accessories HG 22 E D MV C Y Spare parts
Z Main group 3F Insulators MLFB manual 2011 59 3 G Sub group Catalog Product- responsibility A Standardized fuse-links for transformers E D MV C B C Standardized fuse-links for motors E D MV C D HH-fuse-links HG 12 E D MV C E Railway fuses I MO F G HH-fuse-links for direct current H HH-fuse-links bases HG 12 E D MV C J K L M N P Q R S T U V W X Accessories HG 12 E D MV C Y Spare parts Z Main group 3G HH-fuse devices MLFB manual 2011 60 3 K Sub group Catalog Product- responsibility A Load break switches LV, NS PS I BT LV B C Automatic Transfer Switch I BT LV D Switch disconnector I BT LV E Load break switches, LV, NS PS I BT LV load transfer switches parallel switches F Switch disconnector Fuse I BT LV G Rotary bar-type disconnectors, linear-travel I BT LV disconnectors H J K L Load break switches with fuses LV, NS PS I BT LV with isolating plug connector M Load break switches with fuses LV, NS PS I BT LV with isolating plug connector (MCC switches) N P Q Selector switches for railways I MO R S T Load break switches with fuses, I BT LV power distribution U Load interrupter switches NS E I BT LV V Single-throw knife switches NS E I BT LV W Knife switches NS E I BT LV X Accessories LV, NS E, NS I BT LV PS Y Spare parts LV, NS E, NS I BT LV PS Z Main group 3K Disconnectors MLFB manual 2011 61 3 L Sub group Catalog Product- responsibility A Control switches B Control switches for general applications LV I BT LV to 160 A C Control switches as main switches LV I BT LV and EMERGENCY-OFF switches D Control switches as main switches LV I BT LV and EMERGENCY-OFF switches E F Control switches for general applications LV I BT LV to 20 A G H J K L Control pedestals and desks, winch switches for ships M N P Main switches Q Switchgear for railways I MO R Limit switches for operating lifting gear H3 S Control switches for operating lifting gear H 10 T U V W X Accessories LV, NS E I BT LV I MO Y Spare parts H 10 I MO Z Main group 3L Control switches MLFB manual 2011 62 3 N Sub group Catalog Product- responsibility A NH-fuse-links, for cable protection I 2, NS PS I BT LV B NH-fuse-links, for use in mining I 2 I BT LV C Semiconductor fuse-links to 1000 V, DA 94, SD 91, I BT LV for the protection of diodes and thyristors NS PS D NH-fuse-links for device protection I 2, NS PS I BT LV E Semiconductor fuse-links to 2500 V, DA 94, DA 61, I BT LV for the protection of diodes and thyristors NS PS F G NH-disconnecting blade I 2, NS PS I BT LV H NH-fuse bases I 2 I BT LV J Switchable in-line fuse switch-disconnectors LV, NS PS I BT LV K L M N Fuse off-load disconnectors P Fuse switch-disconnectors LV, NS PS I BT LV Q R S T U V W Fuse material to BS and NF standards I 2 I BT LV X Accessories and spare parts for NH-fuses I 2 I BT LV and in-line fuse switch disconnectors Y Accessories and spare parts for NH-fuse LV, NS E, I BT LV switch-disconnectors NS PS Z Main group 3N NH-fuse devices MLFB manual 2011 63 3 P Sub group Catalog Product- responsibility A Starters AW 1 GINO B C D E Resistor units with external cooling GINO F G Field rheostats GINO H J K Starting switches, controllers AW 1 GINO L M Liquid starters N P Resistor units with wire elements H 3 GINO E Q Resistor units with belt elements R Resistor units with cast elements AW 1, H 3 GINO S Resistor units with latticed steel elements H 3 T Resistor units with mixed installation AW 1 U V W X Components, accessories AW 1, H 10 I DT MC Y Spare parts AW 1, H 3, H 10 I DT MC Z Main group 3P Starters, actuators, resistor units MLFB manual 2011 64 3 R Sub group Catalog Product- responsibility A Switchgear combinations for main circuits, I IA CE load feeders B Electronic overload relays LV I IA CE C Electronic circuit breakers for load feeders I IA CE
D E Load feeders (SIRIUS motor starters) in housing LV I IA CE
F Electronic contactors LV I IA CE G Electronic proximity switches (BERO) LV I IA SC, I IA CE contactless, Actuator-Sensor Interface (AS-I) FS 10 H Auxiliary contactors (new range) I IA CE J K Communications capable low-voltage switchgear LV, NS PS I IA CE
L Vacuum contactors M see following pages for released 4-digit subgroups N Thermistor motor protection devices I IA CE P Time relay LV I IA CE Q R Function relay LV I IA CE S Function relay LV I IA CE T Contactors (new range) LV I IA CE U Thermally delayed overload relay LV I IA CE (new range) V Thermal circuit breakers for load feeders LV I IA CE W SIKOSTART electronic motor control devices LV, NS E I IA CE, I IS X Accessories LV I IA CE, I IA SC Y Z Main group 3R Electronic low-voltage switch gears MLFB manual 2011 65 3RM Sub group Catalog Product- responsibility 0 1 Load feeders (SIRIUS motor starters), I IA CE compact hybrid starters 2 3 4 5 6 7 8 9 Main group 3R Electronic low-voltage switch gears MLFB manual 2011 66 3 S Sub group Catalog Product- responsibility A Manually operated command and signaling LV I IA CE devices, with contacts B Manually operated command and signaling LV, NS PS I IA CE devices, with movable double-break contact C Manually operated command and signaling devices, contactless D E Machine operated command and signaling LV I IA CE devices, with contacts (position switches) F Communicable machine operated command and FS 10 I IA SC, I IA CE signaling devices (AS-Interface and DP-Interface) I IS G Electronic proximity switches (BERO), FS 10 I IA SC contactless H J Command cam switches H 3, H 10 I DT MC Gessmann K see following pages for released 4-digit subgroups L Indicator lights M N P Q Control switches for railways I MO R Command and signaling devices NS E, DA 12 I IA CE (non-Siemens development) S T Control switches for auxiliary circuits I IA CE U Command and signaling devices I IA CE (new type series) V Switches for auxiliary circuits NS E, HG 11, E D MV C, LSA 3.2 E D EA W X Accessories LV, NS E, H 3 I IA CE, I DT MC I IA SC, E Gessmann Y Spare parts LV, NS E, H 3 I IA CE, I DT MC Z Main group 3S Command- and signal devices MLFB manual 2011 67 3SK Sub group Catalog Product- responsibility 0 1 SIRIUS Safety Relays I IA CE 2 3 4 5 6 7 8 9 Main group 3S Command- and signal devices MLFB manual 2011 68 3 T Sub group Catalog Product- responsibility A AC contactors and auxiliary contactors I IA CE (old range; new range: 3TF) B Contactors (old range; new range: 3RF, 3TF) LV, NS E I IA CE C DC contactors 1-pole and 2-pole LV, NS E I IA CE D Contactor-type reversing starters LV, NS E I IA CE E Contactor-type star-delta starters LV, NS E I IA CE F Contactors, compact reversing contactors LV, NS E I IA CE G Miniature contactors; special contactors LV I IA CE H Auxiliary contactors LV, NS E I IA CE J Miniature contactors I IA CE K Capacitor switching contactors, contactors with main LV, NS E I IA CE contact elements, Special contactors from auxiliary Contactors 3TH, contactor safety combinations L Vacuum contactors HG 11 E D MV C M Contactors for Medium high voltage E D MV N P Q R S Contactors, external I IA CE T U V W Motor starters LV, NS E I IA CE X Accessories LV, NS E, I IA CE HG 11, NS PS E D MV C Y Spare parts LV, NS E, I IA CE HG 11 E D MV C Z Main group 3T Contactors, contactor combinations MLFB manual 2011 69 3TM Sub group Catalog Product- responsibility 0 1 Vacuum contactors E D MV 2 3 4 5 6 7 8 9 Sub group 3TM Contactors for Medium high voltage MLFB manual 2011 70 3 U Sub group Catalog Product- responsibility A Thermally delayed overload relays LV, H 3, NS E, I IA CE NS PS B Electronic overload relays, tripping units LV, NS E I IA CE Transformers for railway systems C Thermally delayed overload relays, slow LV D E F SIMOCODE system, electronic protection and LV, NS PS I IA CE control component; current converter G Undelayed electromagnetic overcurrent relays LV I IA CE Undelayed electronic current relays H Overcurrent and reverse current relays (electronic) I IA CE J K L Fault current relays LV I IA CE M N Thermistor motor protection equipment, LV I IA CE PTC thermistor P Thermistor motor protection equipment, LV I IA CE NTC thermistor Q Rotor temperature monitoring equipment R S Thermally delayed overload relays I IA CE external T U V W Overload relays for starters LV I IA CE X Accessories and spare parts for 3UA to 3UM LV I IA CE Y Accessories and spare parts for 3UN to 3UW I IA CE Z Main group 3U Overload relays, fault current relais, motor protection equipment MLFB manual 2011 71 3 V Sub group Catalog Product- responsibility 1) A Motor starters with manual operation to 16 A (to 79: I BT LV, I IA CE protective switches for alternating current to 100A) 1) B 4-pole circuit breakers (to 79: circuit breakers I BT LV, I IA CE for alternating current 80 to 630 A) 1) C Motor protection switches for direct current 40 A I BT LV, I IA CE 1) D Circuit breakers for direct current 160 to 300 A I BT LV, I IA CE E Circuit breakers for motor protection LV I BT LV, I IA CE F Circuit breakers MCCB to 2500 A LV, NS PS I BT LV, I IA CE G Crane switches H 3 I IS IMS H SIKUFEST starter combinations NS E I BT LV, I IA CE J K Switches for special purposes L Compact circuit breakers MCCB, 160 - 1600 A I BT LV M 1) N Circuit breakers for starter combinations I BT LV, I IA CE 1) P Non-automatic circuit breakers I BT LV, I IA CE 1) Q Circuit breakers MCCB; non-Siemens I BT LV, I IA CE 1) R Compact circuit breakers MCCB I BT LV, I IA CE slimline (16 - 125 A), compact large design (2000 - 3200 A) 1) S Circuit breakers for motor protection I IA CE external T Compact Circuit breakers MCCB 160 - 1000 A I BT LV U Circuit breakers for motor protection, w 63 A LV, NS E I IA CE V W X Accessories and components LV, NS E I BT LV, I IA CE Y Spare parts I BT LV, I IA CE Z 1) for new use closed since 01.03.2004. Main group 3V Circuit breakers MLFB manual 2011 72 3 W Sub group Catalog Product- responsibility 1) A Load switches I BT LV 1) B Open power switchgroups I BT LV C D E Circuit breakers from 630 A NS E I BT LV F DC switches to 1200 V I MO current limiting circuit breakers from 630 A 1) G Circuit breakers for use on ships H 1) J Circuit breakers R 913 for alternating current I BT LV K L Circuit breakers PCB, 630 - 6300 A I BT LV M N Circuit breakers 630 to 6300 A LV, NS PS I BT LV P 1) Q Circuit breakers R 914 for direct current I BT LV 1) R Circuit breakers for use on ships S Vacuum circuit breakers LV, NS PS I BT LV T Circuit breakers ACB 630A - 3200A I BT LV U V DC high-speed circuit breakers to 1500 V I IS W X Accessories and components LV, NS E, NS I BT LV PS Y Spare parts LV, NS E, NS I BT LV PS I IS Z 1) for new use closed since 01.03.2004. Main group 3W Open circuit breakers MLFB manual 2011 73 3 Z Sub group Catalog Product- responsibility A NS switch gears I IA CE, I BT LV Supply contract Siemens Allis/S E & A B NS switch gears I IA CE Supply contract with outside companies C D E F G H J K Special devices I IA CE, I BT LV custom-designed forms of delivery L Control switches NS E I IA CE, I BT LV M N P Q R S Software for I IA CD I IA CE, I BT LV T U V W Documentation for products of the superordinate I BT LV group 3 for I BT LV X Documentation for products of the superordinate I IA CE, I IA SC group 3 I BT LV Y Accessories and spare parts for products I IA CE of the superordinate group 3 Z Main group 3Z Special equipments MLFB manual 2011 74 3ZW Sub group Catalog Product- responsibility 0 1 Documentation for products of the I BT LV superordinate group 3 for I BT LV 2 3 4 5 6 7 8 9 Sub group 3ZW Documentation for products of the superordinate group 3 MLFB manual 2011 75 3ZY Sub group Catalog Product- responsibility 0 1 Accessories and spare parts for products I IA CE of the superordinate group 3 2 3 4 5 6 7 8 9 Sup group 3ZY Accessories and spare parts for products MLFB manual 2011 76 4 Main group A Dry-type transformers to 16 kVA B Dry-type transformers over 16 kVA C Variable transformers D E Iron-cored reactance coils F Voltage stabilizers and power supplies G Cast resin and other dry-type transformers H TUMETIC liquid-filled transformers J TUNORMA liquid-filled transformers K Components for transformers, REAM, recycling L Current and voltage converters for high voltage M Current and voltage converters for medium-high voltage N Current and voltage converters for low voltage P Reactance coils without iron core Q Magnets R Capacitors (without ceramic capacitors) S T Ceramic cpacitors U V W X Y Z Superordinate group 4 Transformers, Current and voltage transformers, Reactors, Capacitors MLFB manual 2011 77 4 A Sub group Catalog Product- responsibility A Transformers for use with toys I IA CE B C Bell transformers, power supply units I 2 I BT LV D E Transformers, sprayed with molded plastic I IA CE F Cast resin transformers for airport indicator lights G Transformers, cast in cups I IA CE H Transformers for high-frequency application J Standard transformers in general I IA CE K L M Single-phase transformers YEI 1 (EI) and YUI 1 (UI) LV, H 10, R, I IA CE, E NV 31 N Single-phase transformers YUI 1 (UI) NS E I IA CE, E P Three-phase transformers YUI 2 (3UI) LV I IA CE Q Single-phase transformers UI with graded core I IA CE R Three-phase transformers 3UI with graded core I IA CE S Transformers for the N system T Single-phase transformers YUI 1 (UI), LV I IA CE Winding on core U Three-phase transformers YUI 2 (3UI), LV, SD 22 I IA CE Winding on core V Special transformers and DC power supplies LV I IA CE W Ring core transformers LV I IA CE X Non-Siemens transformers LV I IA CE Y Housings, accessories and spare parts I 2, DA 93 I IA CE Z Main group 4A Dry-type transformers to 16 kVA MLFB manual 2011 78 4 B Sub group Catalog Product- responsibility A B C D E F G H J K L M N Single-phase transformers UI/UIS I IA CE P Three-phase transformers 3UI/3UIS I IA CE Q Single-phase transformers UIS with graded core R Three-phase transformers 3UIS with graded core I IA CE S T Single-phase transformers UI/UIS, LV I IA CE Winding on core U Three-phase transformers 3UI/3UIS, LV, SD 22 I IA CE Winding on core V Special transformers I IA CE W X Transformers from a external production I IA CE (merchandise) mdexx GmbH Y Housings, accessories and spare parts I IA CE Z Main group 4B Dry-type transformers over 16 kVA MLFB manual 2011 79 4 C Sub group Catalog Product- responsibility A B C D E F G H Single-phase ring-type variable transformers LV I IA CE J Three-phase ring-type variable transformers LV I IA CE K L M N P Single-phase pillar-type variable transformers LV I IA CE Q Three-phase pillar-type variable transformers LV I IA CE R S T U V W X Y Three-phase pillar-type variable transformers I IA CE Z Main group 4C Variable transformers MLFB manual 2011 80 4 E Sub group Catalog Product- responsibility A Single-phase reactance with powder core mdexx GmbH B C D Three-phase reactance with powder core mdexx GmbH E F Electric filter LV 60 I IA CE G H Iron-cored reactance coils for high-frequency application J Standard reactance coils in general SR 10.6 I IA CE K L M Single-phase reactance coils YEI 1 (EI) R I IA CE N Single-phase reactance coils UI/UIS LV 60 I DT LD, I IA CE P Three-phase reactance coils 3UI/3UIS LV 60 I IA CE Q Single-phase reactance coils UI with graded core R Three-phase reactance coils 3UI with graded core S Transductor reactance coils (Ex) T Single-phase reactance coils YUI 1 (UI), I IA CE winding on core U Three-phase reactance coils YUI 2 (3UI), LV 60 I IA CE winding on core V Special reactance coils LV 60 I IA CE W Ring core reactance coils X Y Housings, accessories and spare parts Z Main group 4E Iron-cored reactance coils MLFB manual 2011 81 4 F Sub group Catalog Product- responsibility A B Power supplies in general I IA CE C DC power supplies LV I IA CE D Switched-mode power supplies I IA CE E F G H J K Magnetic voltage stabilizers LV I IA CE L Transformer voltage stabilizer LV I IA CE M N P Q R S T U V W X Y Accessories and spare parts Z Main group 4F Voltage stabilizers and power supplies MLFB manual 2011 82 4 G Sub group Catalog Product- responsibility A Ds transformers to 10 MVA E T TR B Ds distribution/power transformer, TV 1 E T TR cast resin C Ds auto distribution transformer, cast resin E T TR D Ds converter transformer, cast resin E T TR E Ds grounding transformer, cast resin E T TR F Single-phase transformers to 500 kVA E T TR G Ds neutral electromagnetic, couplers, cast resin E T TR H Ds distribution/power transformer E T TR 3-winder or multiwinder, cast resin J Ds converter transformer, E T TR 3-winder or multiwinder, cast resin K Ds generator protection transformer, R1.2 E T TR cast resin L M Ds auto distribution transformer, cast resin E T TR N Single-phase distribution/power transformer, E T TR cast resin P Single-phase auto distribution transformer, E T TR cast resin Q Single-phase converter transformer, cast resin E T TR R Single-phase generator protection transformer, R1.2 E T TR cast resin S Single-phase auto converter transformer, E T TR cast resin T U V Vibrators E T TR W X Accessories and spare parts E T TR for cast resin and other dry-type transformers Y Ignition transformers E T TR Z Main group 4G Cast resin and other dry-type transformers MLFB manual 2011 83 4 H Sub group Catalog Product- responsibility A B Ds distribution/power transformer, TV 2 E T TR mineral oil filling C Ds auto distribution transformer E T TR D Ds converter transformer E T TR E Ds grounding transformer TV 2 F G Ds neutral electromagnetic coupler E T TR H Ds distribution/power transformer, E T TR 3-winder or multiwinder J Ds converter transformer, E T TR 3-winder or multiwinder K Ds distribution/power transformer, E T TR TUMETIC, Silicon liquid L Ds distribution/power transformer, E T TR TUMETIC, Esters liquid M Ds auto converter transformer E T TR N Single-phase distribution/power transformer E T TR P Single-phase auto distribution transformer E T TR Q Single-phase converter transformer E T TR R S Single-phase auto converter transformer E T TR T U V W X Accessories and spare parts E T TR for transformer with mineral oil fillig Y Z Main group 4H TUMETIC liquid-filled transformers MLFB manual 2011 84 4 J Sub group Catalog Product- responsibility A B Ds distribution/power transformer, TV 2 E T TR mineral oil filling C Ds auto distribution transformer E T TR D Ds converter transformer E T TR E Ds grounding transformer E T TR F G Ds neutral electromagnetic coupler E T TR H Ds distribution/power transformer, E T TR 3-winder or multiwinder J Ds converter transformer, E T TR 3-winder or multiwinder K L Ds distribution/power transformer, E T TR TUNORMA, Esters liquid M Ds auto converter transformer E T TR N Single-phase distribution/power transformer E T TR P Single-phase auto distribution transformer E T TR Q Single-phase converter transformer E T TR R S Single-phase auto converter transformer E T TR T U V W X Accessories and spare parts E T TR for transformers with mineral oil filling Y Z Main group 4J TUNORMA liquid-filled transformers MLFB manual 2011 85 4 K Sub group Catalog Product- responsibility A B Components E T TR for Ds distribution/power transformer, cast resin C Components E T TR for Ds auto distribution transformer, cast resin D Components E T TR for Ds converter transformer, cast resin E Components E T TR for Ds grounding transformer, cast resin F G Components E T TR for Ds neutral electromagnetic coupler, cast resin H Components for Ds distribution/power transformer, E T TR 3-winder or multiwinder, cast resin J Components for Ds converter transformer, E T TR 3-winder or multiwinder, cast resin K L M Components E T TR for Ds auto converter transformer, cast resin N Components for single-phase E T TR distribution/power transformer, cast resin P Components for single-phase E T TR auto distribution transformer, cast resin Q Components E T TR for single-phase converter transformer, cast resin R S Components for single-phase E T TR auto converter transformer, cast resin T Components for Transformer Lifecycle Management E T TR U V W X Corrugated, REAM E T TR (Repairs, spare parts, installation, recycling) Y Z Main group 4K Components for transformers, REAM, recycling MLFB manual 2011 86 4KT Sub group Catalog Product- responsibility 0 1 SITRAM DRY E T TR 2 3 4 5 6 7 8 9 Sub group 4KT Components for Transformer Lifecycle Management MLFB manual 2011 87 4 L Sub group Catalog Product- responsibility A Inductive current converters for SF6 substations E T HP with full isolation B C D E F G H J K L M N Inductive voltage converters for SF6 substations E T HP with full isolation P Q R S T U V W X Y Z Main group 4L Current and voltage converters for high voltage MLFB manual 2011 88 4 M Sub group Catalog Product- responsibility A Indoor support-type current transformers HG 24 E D MV C B Indoor support-type current transformers HG 24, HA 27 E D MV C Indoor bushing-type current converters HG 24, HA 35, E D MV HA 41 D NXAIR bushing-type converter system HA 25 E D MV E Outdoor support-type current transformers HG 24 E D MV C F Outdoor bushing-type current converters G Low-level signal converters E D MV H J K Low-level signal converters in the billing HA 41 E D MV metering panel L M N P Q Indoor voltage converters E D MV C R Indoor voltage converters HG 24, HA 25 E D MV S Outdoor voltage converters HG 24 E D MV C T Voltage converters, special design HA 35 E D MV HA 41 U Voltage converters, special design E D V W X Accessories HG 24 E D MV C Y Z Main group 4M Current and voltage converters for medium-high voltage MLFB manual 2011 89 4 N Sub group Catalog Product- responsibility A Wound instrument transformers I BT LV B Wound instrument transformers, I BT LV explosion or weather-protected C Slip-over transformers LV, NS PS I BT LV D Slip-over transformers, I BT LV explosion or weather-protected E Wound instrument transformers for I BT LV protection purposes F Slip-over transformers I BT LV G Cable-type current transformers I BT LV H J K Voltage transformers I BT LV L M Current converters with transmitter output I BT LV N P Q R S Summation current transformer I BT LV T U V W X Accessories E Y Z Main group 4N Current and voltage converters for low voltage MLFB manual 2011 90 4 P Sub group Catalog Product- responsibility A B C D E Air reactance coils F G H J K Reactance coils with layer winding I IA CE of copper flat wire L M N Reactance coils with spiral winding DA 93 I IA CE of copper flat wire with forced air cooling P Q R Reactance coils with spiral winding I IA CE of aluminium strip S Reactance coils with spiral winding of copper strip I IA CE T U V Reactance coils in special design I IA CE W X Y Accessories and spare parts DA 93 I IA CE Z Main group 4P Reactance coils without iron core MLFB manual 2011 91 4 Q Sub group Catalog Product- responsibility A Deflection magnets B Bubble chamber magnets C Focusing magnets D E F Master magnets G H J K Correction magnets L M N P Test and calibration magnets Q R S Spark chamber magnet T U V W X Y Z Main group 4Q Magnets MLFB manual 2011 92 4 R Sub group Catalog Product- responsibility A B Low-voltage power capacitors I BT LV (formerly Modl GmbH) C D Low-voltage power capacitors in the housing I BT LV (formerly Modl GmbH) E F Reactive power control units with filter circuits I BT LV (formerly Modl GmbH) G H Power capacitors for high voltage from 1000 V HG 25 E D EA with mixed dielectric and all-film dielectric J K L M N P Q R S Filter capacitors HG 25 E D EA T U V Overvoltage protection capacitors HG 25 E D EA W Special equipment for compensation tasks SR 10.6 Modl GmbH Audio frequency blockers X Accessories I BT LV (formerly Modl GmbH) Y Reactive power control units I BT LV (formerly for power capacitors, capacitor control cubicles Modl GmbH) Z Main group 4R Capacitors (without ceramic capacitors) MLFB manual 2011 93 5 Main group A Power cables, paper-insulated B Power cables, rubber and paper-insulated C D Cables for use in power installations E Data cables F Data cables G Power cable accessories and other cable products
H Data cable accessories J K L Luminaires for fluorescent lamps M N Luminaires for other discharge lamps and incandesent lamps P Lamps Q R S Fuse material, Insta protection switches T Insta- and PACCO switches U Plugs and connectors V Insta installation equipment W Signaling and internal phone system devices, alarm signaling systems, automotive electrics, building management systems X Room shielding Y Pre-production KWB products and non-Siemens manufacturers Z Superordinate group 5 Cables, Luminaires and lamps Installation material Electrical automotive products, Room Shielding MLFB manual 2011 94 5 A Sub group Catalog Product- responsibility A Grounding cables with shared Pb sheath SK 2.10 Prysmian B Grounding cables with single Pb sheath SK 2.10 Prysmian C Grounding cables with aluminium sheath SK 2.10 Prysmian D E F Oil-filled cables with Pb or aluminium sheath Prysmian G Gas-filled internal pressure cables or pipe-type cable Prysmian as well as other maximum voltage cables H J K L M N P Q R S T U V W X Y Z Main group 5A Power cables, paper-insulated MLFB manual 2011 95 5 B Sub group Catalog Product- responsibility A Plastic-isolated, without metal sheathing SK 2.10, SK 3.40 Prysmian (not including control cables from 5-core) B C Plastic-isolated, with concentric conductor, SK 2.10, SK 3.40 Prysmian with or without armour D Plastic-isolated, without concentric conductor, SK 2.10, SK 3.40 with armour E Plastic or rubber-isolated control cable, SK 3.40 Prysmian from 5-core F Plastic or rubber-isolated, with Pb sheath SK 3.40 Prysmian G Ships or marine cable SK 1.4, SK 1.41 Prysmian H Installation cable SK 3.40 Prysmian J K L M N SIENOPYR cable SK 2.10, SK 3.30 Prysmian P PROTOTHEN-X cable, PROTOTHEN-XR cable SK 2.10 Prysmian Q R Copper grounding wire SK 3.40 Prysmian S T U Prepared cable Prysmian V W X Cable clamps SK 2.10 Prysmian Y Z Main group 5B Power cables, rubber and paper-insulated MLFB manual 2011 96 5 D Sub group Catalog Product- responsibility A PVC wiring cables and single-core SK 3.40, SK 4.10, Prysmian non-sheathed cables SK 4.20 B Flat webbed cables SK 3.40 Prysmian C Sheath cables SK 3.30 Prysmian D Lead-sheathed cables SK 3.40 Prysmian E PVC flexible sheathed cables, PVC flat cables, SK 1.12, SK 4.20, Prysmian control cables, elevator control cables, SK 4.10 SPREADERFLEX cables F Rubber core cables, high-voltage cables SK 4.10, SK 4.20 Prysmian G Rubber flexible sheathed cables for light SK 1.12, SK 4.10, Prysmian mechanical use, rubber flat cables H Rubber flexible sheathed cables for medium SK 1.12, Prysmian mechanical use, welding cables, SK 4.10/4.20 HYDROFIRM cables J K Trailing cables for lifting gear SK 1.12 Prysmian L Rubber flexible sheathed cables for heavy SK 1.12, Prysmian mechanical use, for industry and mining SK 4.10/4.20 M Special cables for mining SK 1.12 Prysmian N P Heating cables, heating coils, heated mats, Glen Dimplex heated strips Q R Heat-resistant cables SK 4.20 Prysmian S Vehicle cables I IS T Cable sets, vehicle cable sets Prysmian I IS U Applicance cords i-center V Cables for measuring and control technology SK 4.20 Prysmian SK 3.40 W X Prepared cables, SK 4.20 Prysmian Plastic fiber optic cables and systems Y Z Installations, samples, bare copper wire Main group 5D Cables for use in power installations MLFB manual 2011 97 5 G Sub group Catalog Product- responsibility A Indoor sealing ends and cable terminations SK2.50, HG21 RXS with Attachable sealing ends inter-group sales B C D Outdoor sealing ends and cable terminations RXS RXS with inter-group sales E Junction sleeves to 30 kV RXS RXS with inter-group sales F PROTOLIN junction sleeves and tap joints, SK 2.50 RXS with inter- Products for shrink fitting group sales, i-center G H Installation equipment RXS RXS with inter-group sales J Outdoor sealing ends for high-voltage and maximum-voltage cable over 45 kV K Transformer and switch entry sealing ends for high-voltage and maximum-voltage cables over 45 kV L Sleeves for high-voltage and maximum-voltage cables over 45 kV M Accessories for high-voltage and maximum-voltage cables over 45 kV N P Q R Special accessories RXS RXS with for impulse-short-circuit-proof sealing ends inter-group sales S Cable spreaders RXS RXS with inter-group sales T Terminating sleeves, connection bolts, SK 2.50 i-center, cable shoes, solder sleeves, brass pins, RXS with i-g sales claw-type terminals U Compounds, cast resin, varnish SK 1.12, RXS Prysmian, i-center, Indoor terminations for lifting gear trailing cables RXS with i-g sales V Winding and solder material, SK 2.50 RXS with insulation sleeving, and similar inter-group sales W X Y Insulation ans sheath mixes for cables Z Main group 5G Power cable accessories and other cable products MLFB manual 2011 98 5 L Sub group Catalog Product- responsibility A Outdoor luminaires Outdoor Siteco lighting B BS 900 lighting system Indoor Siteco luminaires C SiNOVA, wallwashers Indoor Siteco luminaires D SiDEKO luminaires Indoor Siteco luminaires E Other luminaires Indoor Siteco, i-center luminaires F G SiGRO indoor SiGRO-Industrie H J Indoor luminaires Indoor Siteco, i-center luminaires K Indoor luminaires Indoor Siteco luminaires L M Luminaires for the home Indoor Siteco luminaires N P Q R S Special luminaires Indoor Siteco, i-center luminaires T U V Stage luminaires W X Individual parts for old, no longer numbered Siteco luminaires Y Accessories, individual parts and spare parts Outdoor and Siteco, i-center (not restricted to type) indoor luminaires Z Control gear Outdoor and Siteco, I BT LV indoor luminaires Main group 5L Luminaires for fluorescent lamps MLFB manual 2011 99 5 N Sub group Catalog Product- responsibility A Outdoor luminaires for other discharge lamps Outdoor Siteco lighting B C Outdoor luminaires for incandescent lamps Outdoor and Siteco, i-center indoor luminaires D E Other luminaires for other discharge lamps Indoor Siteco, i-center luminaires F G Other luminaires for incandescent lamps Indoor Siteco, i-center luminaires H J Indoor luminaires for other discharge lamps Indoor Siteco, i-center luminaires K L Indoor luminaires for incandescent lamps Indoor Siteco, i-center luminaires M N Signal and lighting equipment for other discharge I IS lamps and incandescent lamps (airport lighting systems) P Equipment for airport lighting systems I IS Q Signal and lighting equipment for incandescent Outdoor I IS lamps (airport lighting systems) lighting R S Special luminaires for other discharge lamps Indoor Siteco, i-center luminaires T Stage luminaires and spotlights for other discharge lamps U Special luminaires for incandescent lamps i-center V Stage luminaires and spotlights for incandescent lamps W X Individual parts for old, no longer numbered luminaires Y Accessories, individual parts and spare parts Outdoor and Siteco, i-center (not restricted to type) indoor luminaires Z Control gear Outdoor and Siteco, i-center indoor luminaires Main group 5N Luminaires for other discharge lamps and incandesent lamps MLFB manual 2011 100 5 P Sub group Catalog Product- responsibility A General purpose lamps i-center B General purpose lamps i-center C D DULUX compact fluorescent lamps i-center E F Vehicle lamps i-center G Devices, sets, reflector lamps, lighting ideas i-center H Halogen lamps i-center J K Christmas lights i-center L Fluorescent lamps i-center M Mixed-light lamps i-center N Sodium-vapor lamps i-center P Photographic lightings i-center Q Mercury-vapor high-pressure lamps i-center R S Other light sources, photographic/optical i-center Traffic signal lamps and signal lamps T U V W Projector lamps i-center X Xenon lamps, pulsed lamps i-center Y Z Accessories i-center Main group 5P Lamps MLFB manual 2011 101 5 S Sub group Catalog Product- responsibility A DIAZED fuse links (E16), I 2 I BT LV Miniature fuses B Original-DIAZED fuse-links, I 2 I BT LV Size II and III C Original-DIAZED fuse-links, I 2 I BT LV Size IV and V D Special-DIAZED fuse-links, I 2 I BT LV Overvoltage protection equipment E NEOZED fuse-links I 2 I BT LV F DIAZED fuse-bases I 2 I BT LV G NEOZED fuse-bases I 2 I BT LV MINIZED load switches H Accessories for DIAZED- and NEOZED fuse material I 2, NS PS I BT LV
J Si automatic screw automat I 2 I BT LV Circuit breakers (LS 63R residental) K WN automat (switching capacity 1.5 kA) - discontinued I 2 I BT LV MCB compact system, Circuit breaker terminals L Circuit breaker >N< (switching capacity 10kA) - discontinued I 2 I BT LV MCB (residential and commercial design) M S automat, I 2, NS PS I BT LV Railable fault current protection equipment, FJ block N Circuit breakers>N< (switching capacity 6 kA) I 2 I BT LV P W automat (switching capacity 1.5 kA) SHU switches I 2 I BT LV Circuit breakers (LS 125 industry+functional building) Q Circuit breakers >N< (ND) I 2 I BT LV R Overload switches, telecommunications I BT LV circuit breakers S Miniature circuit breakers (relay-fuse miniature I BT LV circuit breakers) T Accessories and supplementary components I 2 I BT LV for circuit breakers U Fault current circuit breakers, combined I 2 I BT LV V SFJ fault current circuit breakers - discontinued I 2, LV I BT LV Residual Current Protective Devices (RCD) with 5SL-Design Residual Current Monitor (RCM) W Accessories and supplementary components I 2, NS PS I BT LV for fault current protective equipment X Circuit breakers >N< with shock-proof terminals I 2, NS PS I BT LV and supplementary components Y Circuit breakers (LS63 industry + functional building) I 2 I BT LV Z Fault current protective equipment >N<, I 2, NS PS I BT LV small construction Main group 5S Fuse material, Insta protection switches MLFB manual 2011 102 5 T Sub group Catalog Product- responsibility A DELTA switches I 2 I BT LV B Toggle switches I 2 I BT LV C Dimmers, infrared systems, RF systems, I 2 I BT LV motion detectors, lighting control devices D DELTA pushbuttons, DELTA light signals I 2 I BT LV and information indicators E DIN rail mounted devices I 2 I BT LV (switches, pushbuttons, light signal, socket) F G DELTA design parts, Spare parts, supplementary I 2 I BT LV devices and accessories for switches, pushbuttons and dimmers H J K Packet-type switches (PACCO control switches), 16 A I 2 I BT LV L Packet-type switches(PACCO control switches), 25 A I 2 I BT LV M N Packet-type switches (PACCO control switches), 40 A I 2 I BT LV P Packet-type switches (PACCO control switches), 63 A I 2 I BT LV Q Packet-type switches (PACCO control switches), for special purposes R Packet-type switches (PACCO), from 100A - discontinued I 2 I BT LV Transfer Switching Equipment (TSE) S Accessories and spare parts for packet-type switches I 2 I BT LV (PACCO control switches) T Time switches,remote-control switches,all-or-nothing I 2 I BT LV relays, priority switches U V W X Y Z Main group 5T Insta- and PACCO switches MLFB manual 2011 103 5 U Sub group Catalog Product- responsibility A Socket-outlets without ground contact I 2 I BT LV B Grounding outlets, socket-outlets I 2 I BT LV with ground contact C Grounding plugs and portable socket-outlets i-center D E F G H Accessories and spare parts for socket-outlet I 2 I BT LV systems J K RD shrouded plug and socket outlets, 5-pin i-center L RD shrouded plug and socket outlets M N NOVA shrouded plug and socket outlets i-center P PERILEX plug and socket-outlets i-center Q CEE shrouded plug and socket outlets, i-center with cast-metal housing R CEE und CEKON shrouded plug and socket outlets i-center (plastic) S Plug and socket-outlets for use on ships T Plug and socket-outlets for the stage and i-center television studios U Plug and socket-outlets for use on railways V W Accessories and spare parts for special plug i-center and socket-outlets X Y Z Main group 5U Plugs and connectors MLFB manual 2011 104 5 V Sub group Catalog Product- responsibility A Tap boxes and accessories I 2 i-center, I BT LV B Insta pipes with accessories i-center C Fixing material, cable clamps SK 1.22, I 2 I IS, I BT LV D Terminals and accessories I 2 i-center, I BT LV E SMS universal fast installation system I 2 I BT LV F Compression glands, cable glands, i-center self-sealing grommets G H J Insulating material i-center K Grounding material i-center L M Installation ducts i-center cable racks and systems N Installation ducts NS PS i-center P Telephone sockets I BT LV, i-center Q R Underfloor system I BT LV, i-center S T U V Installation material for prefabricated buildings i-center W Tools, batteries SK 1.22, I IS, i-center NS E, SK 2.50 Prysmian X Y Z Main group 5V Insta installation equipment MLFB manual 2011 105 5 W Sub group Catalog Product- responsibility A Bell pushbuttons, contacts devices for alarm I 2 I BT LV, i-center signaling systems, domestic electronics B Bells, buzzers, gongs I 2 I BT LV, i-center C Door and gate intercom systems and accessories I 2 I BT LV D Light current switches and door openers i-center E Floor signplates and accessories i-center F G instabus EIB I 2 I BT LV H Connection components for data and voice networks, i-center accessories for light current material (e.g. cables) J K Automotive electronics formerly automotive engineering L M N P Automotove electronics formerly automotive engineering Q R S Suction modules formerly automotive engineering T U Application systems and measuring systems for the formerly automotive automotive industry engineering V W X Y Printed circuit boards for installation devices formerly automotive engineering Z Main group 5W Signaling and internal phone system devices, alarm signaling systems, automotive electrics, building management systems MLFB manual 2011 106 5 Y Sub group Catalog Product- responsibility A Drawn wires B Crimped wires C Rods D Louvres E Profile wires F Contact wires G Belts H Sundry copper material J Rods K Profile wires L Belts M Sundry brass material N Drawn wires P Rods Q Profile wires R Belts S Sundry aluminium material T Sintered parts U Tools V Various W X Y Z Main group 5Y Pre-production KWB products and non-Siemens manufacturers MLFB manual 2011 107 6 Main group A Industrial automation systems (software) B Industrial automation systems (software) C D Closed-loop control: components and systems E Open-loop control: SIMATIC automation systems; SITOP (SIPAC) power supply system F Open-loop and closed-loop control: application-oriented systems and components G Open-loop and closed-loop control: Devices and plant sections H J K Encoders and monitoring devices, display blocks L (reserved for instrumentation and control) M Instrumentation and control components and systems for substation control and protection (LSA) N Components and systems for power systems control P Control equipment for semiconductor converters Q Power sections for semiconductor converters R Semiconductor converters with DC output S Semiconductor converters with AC or three-phase output T U High-voltage valves and converters V Open-loop and closed-loop control, components for electric mobility W X Mechanical components and accessories Y Z Cross-product articles of superordinate group 6 Superordinate group 6 Industrial automation systems Control and computer systems Converter systems MLFB manual 2011 108 6 A Sub group Catalog Product- responsibility A CPUs PR2., PR 3., IC, I IS MC B I/O memory PR 2., PR 3., IC, I IS MC C Terminals PR 2., PR 3., IC, ST 80E I IS NLT 4, CTS, MC D Components for data transmission PR 2., PR 3., IC I IS E F Process unit PR 2., PR 3., IC I IS MC G SIPLUS - System technology for SIMATIC I IA CE, I IA AS H J System components in general PR 2., PR 3., IC, I IS NLT 4, MC K L Basic systems, packages PR 3. I IA AS M SIMICRO SX microcomputer systems, hardware PR 60 I IA CE N SIMICRO SX microcomputer systems, software PR 60 I IA CE P Industrial PCs: basic systems, components, IC, KT 22 I IS, I IA CE accessories, spare parts Q R SICOMP IMC industrial microcomputers IC 50, KT 51, I IA CE KT 52 S Operating systems and software technology, IC 50 I IA AS, I IS SORIX T System solutions for industry (e.g. plastics, SL I DT MC, I IA CE packaging, textiles, presses, woodworkung, glass, ceramics, stoneworking) U Motion Control System SIMOTION I DT MC, I DT LD
V SIMATIC HMI (HUMAN-Machine-Interface) ST 80, ST 9.80, I IA AS, I IS COROS operator control and monitoring systems ST 80 E W MOBY RF identification systems PR 2., PR 3., I IA SC Application-oriented process I/O IC, KT 21, MC X Accessories PR 2., PR 3., IC I IA AS Y Spare parts PR 2., PR 3., IC, I IS KT 22 Z Main group 6A Industrial automation systems (software) MLFB manual 2011 109 6 B Sub group Catalog Product- responsibility A System program packages PR 2., PR 3.,MC3, I IA AS, I IA SC ST 9.80, KT 21 I IA CE, I IS B Organization programs PR 3., MC, Moby I IS, E D EA IK, IC, PR 2 I IA AS, I IA CE C Backup programs PR 3., KT 21 I IA CE D Compiler programs PR 2., PR 3., I IA CE, I IA AS ST 9, IC E D EA E Utility programs PR 2., PR 3., I IA CE ST 9.80, MC F G H J Programming aids PR 3., ST 9.80, I IA CE MC I IS K Diagnostic tools for KT 51 I IA CE Automation and Drive Systems L M N P User-oriented system programs: communications Q General application software for I IA AS, I IA CE automation engineering (AUT) I DT MC R S User-oriented system programs: PR 3., I IA AS process automation PR 2., IC 50 T U V W User-oriented system programs: for automation in PR 2., PR 3. the finishing industries and in administrative offices X Y User-oriented system programs: PR 3., PR 2. test and maintenance programs Z Main group 6B Industrial automation systems (software) MLFB manual 2011 110 6 D Sub group Catalog Product- responsibility A B C SIMADYN C DA 69 E I IA AS DA 97 D SIMADYN D DA 99, DA 99 E, I IA AS, I DT LD DA 91 E E F G H J K Operation control system for power plants E (PG L5) L TELEPERM/SIMATIC PCS 7 PLT, KT I IA CE, I IA AS M MODULPAC C DA 98, DA 98 E I DT LD N PROFIT Solutions/Services LT E (PG L3) P TELEPERM XP instrumentation and control LT 600 E (PG L61) system Q Instrumentation and control service for E (PG L2) power stations R Electrical and electromechanical MP 31 I IA SC compact controllers (TELEPERM D) S TELEPERM M/ME ST 80 E, PLT, LT I IA AS, I IA CE, ST 9.80 E (PG L 61) T TELEPERM C/power controllers TELEPERM MP 32, LT E (PG L61) U Instrumentation and control system, next E (PG L611) generation V W X Y Z Main group 6D Closed-loop control: components and systems MLFB manual 2011 111 6 E Sub group Catalog Product- responsibility A SIMATIC S 5 automation system ST 70, ST 9 I IA AS (see also 6ES) B I IA AS C SIMATIC C1, C2, C3 ST 9 I IA CE control systems D LOGO! control system I IA AS E F SIMATIC N constrol systems I IA AS G H J K L M SIMATIC MS signaling system,MB message ST 9.31 I IA CE printer N P SITOP power supplies and system cabling KT 10 I IA CE, I IA AS Q SIMATIC PCS7/APACS+/505, Software I IA AS R SIMATIC S 5, S 7, M 7, SC automation systems IPC 10, IK, KT 10, 21, I IA AS, I DT MC S SIMATIC P, M, S 3 control systems ST 50, 70, 80, 80E, I IA CE, I IA SC ST 9, 9.80, NS PS T U V Power supply units DA 97, ET 1, 9, I IA AS, I DT MC ST 9, NC, KT 10 I IA CE W SIPAC power supply system ET 9, ST 22, ST 50, I IA AS, I DT MC Switched-mode power supply units ST 70, ST 9, NC, I IA CE, I DT LD KT 10 I IS X Accessories Y Spare parts ST 9 I IA AS Z Main group 6E Open-loop control: SIMATIC automation systems; SITOP (SIPAC) power supply system MLFB manual 2011 112 6 F Sub group Catalog Product- responsibility A B for elevator control C SINUMERIK machine tool controls, NC, AR I DT MC NC accessories, service provision D for pulp/paper industries and the printing I IA AS industry E eMobility I IA CE F for generator and transformer regulation G for industrial drives H for agricultural vehicles I DT LD J for waterworks K for nuclear plants LT 4. FRAMATOME ANP L for heating, ventilation and air conditioning BA I BT, I DT MC, I IA SC systems I IS M Equipment for finishing machines and special AR 10, NCZ I DT MC machines, WS 8000 overall equipment sets NC 60, SL N for network automation (power frequency control) P for power station automation LT, MP 32 E (PG L6) (open-loop control) Q for power station automation LT E (PG L6) (closed-loop control) R SIROTEC robot controls NC 50, NC 51 I DT MC S for marine automation T U V W Other DA 97 I IA AS X Accessories, connections NC, ST 9, AR I DT MC Y Z Main group 6F Open-loop and closed-loop control: application-oriented systems and components MLFB manual 2011 113 6FE Sub group Catalog Product- responsibility 0 1 SIPLUS ECC - eCar charging components I IA CE 2 3 4 5 6 7 8 9 Sub group 6FE eMobility MLFB manual 2011 114 6 G Sub group Catalog Product- responsibility A for electrical machines (generators, motors, H 2, H 3, H 4 I DT MC converters) Gessmann B for prime movers and systems C for transformers, capacitors R E D EA D E for light control F Image evaluation systems FS 10, ST 50, I IA SC, I IA CE ST 70, ST 9 I IA AS G H J Other devices for electrical and non-electrical variables K SIMATIC NET industrial communications networks IK, ST 70, I IA AS, I IA CE (SINEC) ST 9.80 I IA SC L Flexible manufacturing systems (FMS) AR 21 I DT MC M N P Q for transport systems R SIMATIC SENSORS PX and FS I IA SC S T Industrial automation systems: MOBY KT 21, FS 10 I IA SC indentification systems U V W X Accessories R 1.2 E D EA Y Z Main group 6G Open-loop and closed-loop control: Devices and plant sections MLFB manual 2011 115 6 K Sub group Catalog Product- responsibility A Central processing units PR2., PR 3., IC, I IA AS, I MO MC I DT MC, Gessmann B Peripheral lofts PR 2., PR 3., IC I IA AS MC I IS C Terminals PR 2., PR 3., IC, ST 80E I IA AS, I IS NLT 4, CTS, MC E D EA, I IA CE D Components for the data transmission PR 2., PR 3., IC I IA AS I IA CE E F Process unity PR 2., PR 3., IC I IA AS MC I IS G SIPLUS - systems engineering for SIMATIC I IA CE H J System components general PR 2., PR 3., IC I IA AS NLT 4, MC I IS K L Base systems, packages PR 3. I IA AS M Microcomputer systems SIMICRO SX, hardware PR 60 I IA CE N Microcomputer systems SIMICRO SX, software PR 60 I IA CE P IndustryPC: Base systems, components, IC, KT 22 I IS accessories, spare parts Q R Industry microcomputer SICOMP IMC IC 50, KT 51, I IA AS KT 52 I IA CE S Operating systems and software technology, SORIX IC 50 I IA AS, I IS T System solutions for the industry (e.g. synthetic SL I DT MC, I IA CE material, packing, textile press, wood, glass, ceramic, stone.) U Motion Control System SIMOTION I DT MC (UMC) V SIMATIC HMI (humane machine interface) ST 80, ST 9.80, I IA AS, I IA SC using and observation systems COROS ST 80 E I IS W RF-indentification systems MOBY PR 2., PR 3., I IA AS application-oriented process interface equipment IC, KT 21, MC I IA CE X Accessories PR 2., PR 3., IC I IA AS Y Spare parts PR 2., PR 3., IC I IA AS, I IS KT 22 I IA CE Z Main group 6K Encoders and monitoring devices, display blocks MLFB manual 2011 116 6 M Sub group Catalog Product- responsibility A Module for LSA 678 LSA 1 E D EA B Devices for LSA 678 LSA 1 E D EA C Software for LSA 678 LSA 1 E D EA D SICAM power automation SICAM, NS PS E D EA E Telegyr telecontrol engineering E D EA F SAT power automation E D EA G H J K L M N P Q R S T U V W X Fuse assemblies for the 6MB LSA 1 E D EA substation control and protection system Y Z Main group 6M Instrumentation and control components and systems for substation control and protection (LSA) MLFB manual 2011 117 6 N Sub group Catalog Product- responsibility A EFD technology NLT 1 E D EA B EFI technology E D EA C EFS technology NLT 1 E D EA D FW 535/537 telecontrol system NLT 1 E D EA E FW 517 telecontrol system NLT 1 E D EA F FZK 300 technology G Telecontrol components NLT 1 E D EA H SINAUT telecontrol system (Pipelines/Networks) IK I IA SC J K Telecontrol components, telecontrol interface NLT 4 E D EA and nodes L M Counter systems NLT 1 E D EA N Power control Systems E D EA Transmission and Distribution P Q R Audio-frequency remote control system S T U V W X Non-system-tied components NLT 1, NLT 3 E D EA W12 I IA CE Y Z Main group 6N Components and systems for power systems control MLFB manual 2011 118 6 P Sub group Catalog Product- responsibility A Components for trigger equipments DA 95 I DT LD B C Trigger equipments DA 95 I DT LD D E F G Pulse amplifiers DA 95 I DT LD H J K L M N P Q R S T U V W X Y Z Main group 6P Control equipment for semiconductor converters MLFB manual 2011 119 6 Q Sub group Catalog Product- responsibility A Thyristor and diode components DA 92 I DT LD B Thyristor and diode columns I DT LD with air and water cooling C Cabinets with thyristor and diode components I DT LD D E F G Air-cooled converter sets for line-commutated DA 91, DA 91 E I DT LD converter (SITOR) H J K L M Additional modules (e.g. overvoltage protection DA 69 E I DT LD circuits, cabinet heating, etc.) N Modules for pulse transmission and switching DA 95, DA 69 E, I DT LD DA 91E P Q R S T U V W X Accessories (e.g. short-circuiter, quick-release DA 21 E, DA 69 E, I DT LD circuits) DA 91 E, DA 91, DA 95 Y Spare parts DA 91 E I DT LD Z Main group 6Q Power sections for semiconductor converters MLFB manual 2011 120 6 R Sub group Catalog Product- responsibility A Devices with commutated converters for DA 21, I DT LD motor feed (SIMOREG), SIMODRIVE SD 22, H4 B Devices with self-commutated DC spots for SD 85 I DT MC motor feed C Devices for battery charging I DT LD D Devices for mains feed I DT LD E Devices for galvanotechnology F G Digital exciter equipment (THYRISIEM) I DT LD H J K for feeding telecommunications systems L for other applications I DT LD M Cabinets for DC drives DA 22, DA 21 I DT LD N Supplements for converters I DT LD P Q R S for traction vehicles T U for generator excitation E V for gas and steam generator I DT LD Startup and excitation (THYRIPOL) W X Accessories DA 98, DA 61 I DT LD Y Spare parts DA21 E, DA61 E, I DT LD DA68 E, SD 91 I DT MC Z Main group 6R Semiconductor converters with DC output MLFB manual 2011 121 6 S Sub group Catalog Product- responsibility A Devices for mains feed (inverters and UPS I DT MC devices) B Load commutated converters (SIMOVERT S) I DT LD C Converters with self-commutated inverters for DA 62, DA 66, I DT LD, I DT MC motor feed (SIMOVERT A, F, P, V), DA 69 E, SD.. SIMODRIVE converter systems D Converters with commutated inverters and direct DA 61 I DT LD converters for motor feed (SIMOVERT C, D) E Transistor converters with self-commutated DA 4., DA 6., I DT MC, I DT LD inverters for motor feed, medium-high voltage DA 25, DA63 converters (SIMOVERT F, P, MV) F AC and three-phase actuator for DA67 I DT LD power controllers (SIMOSTART MV) G AC and three-phase actuator for DA 21, DA 68 I DT MC, I IS power controllers (SIVOLT) H AC actuator for chemical industry I DT LD J K Devices for feeding telecommunication systems L SINAMICS I DT LD, I DT MC M Converters for multi motor drive (SIMOVERT M) DA I DT MC N SIMODRIVE converter systems SD.., NC 60.1 I DT MC P Q Power conditioners (SIPCON) SR 10.5 E D (MASTERDRIVE pulse converters) R Robicon, Perfect Harmony I DT LD S for traction vehicles I DT LD T Converters for special machines I DT LD U Uninterruptible power supplies (UPS) Masterguard GmbH V Electroauto converters W Software DA 66.1, DA 65 I DT MC, I DT LD X Accessories I DT MC, I DT LD Y Spare parts (universal parts, DA 69 E, SD 91 I DT MC, I DT LD identical parts) I IS Z Main group 6S Semiconductor converters with AC or three-phase output MLFB manual 2011 122 6SH Sub group Catalog Product- responsibility 0 1 1st generation I DT LD 2 3 4 5 6 7 8 9 Sub group 6SH AC actuator for chemical industry MLFB manual 2011 123 6 U Sub group Catalog Product- responsibility A B C Selenium high-voltage valves D E F G H J K Devices for other applications L M Modules essentially HG N P Q R S T U V W X Y Z Main group 6U High-voltage valves and converters MLFB manual 2011 124 6V Sub group Catalog Product- responsibility A B C see following pages for released 4-digit subgroups I DT EC D E F G H J K L M N P Q R S T U V W X Y Z Main group 6V Open-loop and closed-loop control, components for electric mobility MLFB manual 2011 125 6VC Sub group Catalog Product- responsibility 0 1 Various components for electric vehicle I DT EC drives 2 Converters for electric vehicle drives I DT EC 3 4 5 6 7 8 9 Main group 6V Open-loop and closed-loop control, components for electric mobility MLFB manual 2011 126 6 X Sub group Catalog Product- responsibility A B ES 902 mounting rack KT 10, KT 9... I IA CE C D E F Empty plug-in modules KT 9 I IA CE LSA 3.1 G Housings KT 9, ST 9 I DT MC H J K Swivel and hinged frames KT 9 I IA CE L M N P Standardized wiring, connection and KT 10 I IA CE installation components Q R S T U Frontplate installation elements V Connectors, connecting cables, cables PR 2., PR 3., IC, ST 9, I IA AS, I IA SC ST 80, IK, KT 21, LSA E W X Test modules, connection and wiring DA95, ET 1, I IA CE, I DT LD accessories and miniature accessories KT 9, KT 10 Y Z Main group 6X Mechanical components and accessories MLFB manual 2011 127 6 Z Sub group Catalog Product- responsibility A Software of I IS IT I IS B Information and training for automation systems ITC, ST 70, I IA AS, I IA SC NC, AR, SD I DT MC C D E F G H J K L M N P Q R S T U V W X Y Spare parts of primary group 6 that cannot be DA 91 E I DT LD assigned to specific main groups SD 91 I DT MC Z Main group 6Z Cross-product articles of primary group 6 MLFB manual 2011 128 7 Main group A AC meters B Three-phase three-wire meters C Three-phase four-wire meters D E Electronic electricity meters F Duplicating meters G Special meters H J K Electrical and electronic measuring instruments, analyzers, time meters L Time switches M Measured-quantity-related measuring instruments and devices for process engineering N Adapters, indicating instruments and recording instruments for process engineering P All-or-nothing relays Q R Measuring relays S Power-system protection, devices and instruments T Withdrawable modules for protection equipment U Machine protection, devices and instruments V Devices for miscellaneous tasks W X Accessories for meters, protective devices and relays Y Z Product-overlapping equipment of superordinate group 7 Superordinate group 7 Electricity meters Measurement technology products, Protection devices and relays MLFB manual 2011 129 7 A Sub group Catalog Product- responsibility A Active-energy meters Z 9 Landis & Gyr AG B Reactive volt-ampere meters (also fr three-phase systems with evenly loaded main conductors) C D Active-energy meters for 3-phase 3-wire systems Landis & Gyr AG with evenly loades main conductors E Active-energy meters for 3-phase 4-wire systems Landis & Gyr AG with evenly loades main conductors F Precision and reference meters for active-energy consumption G Precision impulsing meters H J Impulsing meters for active-energy consumption Landis & Gyr AG K Impulsing meters for reactive volt-ampere consumption L Impulsing meters for active-energy consumption Landis & Gyr AG 3-phase 3-wire systems with evenly loades main conductors M Impulsing meters for active-energy consumption Landis & Gyr AG for 3-phase 4-wire systems with evenly loaded main conductors N P Q R S T U Overrange meters for active-energy consumption, Overconsumption meters for active-energy cons. V W X Y Z Main group 7A AC meters MLFB manual 2011 130 7 B Sub group Catalog Product- responsibility A Active-energy meters Z 9 Landis & Gyr AG B Reactive volt-ampere meters Z 9 Landis & Gyr AG C Apparent-energy meters D E F Precision and reference meters for active-energy Z 9 Landis & Gyr AG consumption G Precision impulsing meters for active-energy Z 9 Landis & Gyr AG consumption H J Impulsing meters for active-energy consumption Z 9 Landis & Gyr AG K Impulsing meters for reactive volt-ampere Z 9 Landis & Gyr AG consumption L M Maximum-demand meters for active-energy Landis & Gyr AG consumption N Maximum-demand meters for reactive volt-ampere Landis & Gyr AG consumption P Maximum-demand meters for apparent-energy consumption Q Maximum-demand impulsing meters for Landis & Gyr AG active-energy consumption R Maximum-demand impulsing meters for reactive Landis & Gyr AG volt-ampere consumption S Maximum-demand precision meters for Landis & Gyr AG active-energy consumption T Maximum-demand precision impulsing meters Landis & Gyr AG for active-energy consumption U Overrange meters for active-energy consumption, overconsumption meters for active-energy consumption V W X Y Z Main group 7B Three-phase three-wire meters MLFB manual 2011 131 7 C Sub group Catalog Product- responsibility A Active-energy meters Z 9 Landis & Gyr AG B Reactive volt-ampere meters Z 9 Landis & Gyr AG C Apparent-energy meters D E F Precision and reference meters for active-energy Z 9 Landis & Gyr AG consumption G Precision impulsing meters for active-energy Z 9 Landis & Gyr AG consumption H J Impulsing meters for active-energy consumption Z 9 Landis & Gyr AG K Impulsing meters for reactive volt-ampere Z 9 Landis & Gyr AG consumption L M Maximum-demand meters for active-energy Landis & Gyr AG consumption N Maximum-demand meters for reactive volt-ampere Landis & Gyr AG consumption P Maximum-demand meters for apparent-energy consumption Q Maximum-demand impulsing meters for active- Landis & Gyr AG energy consumption R Maximum-demand impulsing meters for reactive Landis & Gyr AG volt-ampere consumption S Maximum-demand precision meters for active- Landis & Gyr AG energy consumption T Maximum-demand precision impulsing meters Landis & Gyr AG for active-energy consumption U Overrange meters for active-energy consumption, overconsumption meters for active-energy consumption V W X Y Z Main group 7C Three-phase four-wire meters MLFB manual 2011 132 7 E Sub group Catalog Product- responsibility A AC meters for active-energy consumption B Three-phase four-wire meters for volt-ampere Z 9 Landis & Gyr AG consumption C Three-phase four-wire meters for active-energy Z 9 Landis & Gyr AG consumption D Four-wire meters for active-energy and reactive Z 9 Landis & Gyr AG volt-ampere consumption E F G Three-phase three-wire meters for reactive Landis & Gyr AG volt-ampere consumption (BV; 3L) H Three-phase three-wire meters for active-energy Landis & Gyr AG consumption (WV; 3L) J Three-wire meters for active-energy and reactive Z 9 Landis & Gyr AG volt-ampere consumption (measurement of reactive volt-ampere consumption in a superimposed circuit) K Three-phase three-wire meters for active-energy Z 9 Landis & Gyr AG consumption L Three-phase three-wire meters for reactive volt- Z 9 Landis & Gyr AG ampere consumption (measurement of volt-ampere consumption in a superimposed circuit) M N Three-phase four-wire meters for reactive volt- Landis & Gyr AG ampere consumption (measurement of reactive volt- ampere consumption with phase-shifting elements) P Four-wire meters for active-energy and reactive volt- Landis & Gyr AG ampere consumption with phase-shifting elements) Q Three-wire meters for active-energy and reactive volt- Landis & Gyr AG ampere consumption (measurement of volt-ampere consumption with phase-shifting elements) R Three-phase three-wire meters for reactive volt-meter Landis & Gyr AG consumption (measurement of reactive volt-ampere consumption with phase-shifting elements) S Four-wire meters for active-energy consumption Landis & Gyr AG with digital measuring T Four-wire meters of active-energy and reactive volt- Landis & Gyr AG ampere consumption with digital measuring U Three-wire meters for active-energy consumption Landis & Gyr AG with digital measuring V Three-wire meters for active-energy and reactive Landis & Gyr AG consumption with digital measuring W X Y Z Active-energy and reactive volt-ampere consumption Landis & Gyr AG meters from Siemens Metering Main group 7E Electronic electricity meters MLFB manual 2011 133 7 F Sub group Catalog Product- responsibility A Duplicating registers and duplicating summators B Serval duplicating registers combined in a shared housing C Duplicating registers and duplicating summators with a pulse generator D Maximum-demand printers Landis & Gyr AG E Maximum-demand dry-stylus recorder F G H J K Maximum-demand stylus printers L Maximum-demand hole punch M Indicating maximum-demand mechanisms Z 9 Landis & Gyr AG N P Solid-state duplicating registers Landis & Gyr AG Q R Duplicating meter relays Z 9 Landis & Gyr AG S Special devices of the solid-state Landis & Gyr AG duplicating meter system T U V W Maximum-demand monitors and adjusting gear Landis & Gyr AG X Accessories, modules are parts of the Z 9 Landis & Gyr AG duplicating meters Y Z Main group 7F Duplicating meters MLFB manual 2011 134 7 G Sub group Catalog Product- responsibility A DC watthour meters Z 9 Landis & Gyr AG B C D E F G Solid-state household gas meters Landis & Gyr AG H J DC pulse-generator watthour meters Z 9 Landis & Gyr AG K L M N P Q R Special AC meters S T Special three-phase four-wire meters U V Software for meter-reading detection and processing Z 9 Landis & Gyr AG
W X Y Z Main group 7G Special meters MLFB manual 2011 135 7 K Sub group Catalog Product- responsibility A Analog measuring devices ART I IS B Digital measuring devices and measuring ART I IS modules C Recording measuring devices ART, MP 20 I IS, I IA SC D Oszilloscopes, logic analyzers, generators ART I IS E Measuring and test equipments RT 10, SR 10 I IA AS, E D EA F G Components of the AFM system MP 56, SR 10.4 E D EA, I IS H J K Communiction measuring devices Fa. Tektronix L M Power Monitoring Devices I BT LV N P X-ray analyzers MP 42, MP 42 E Fa. Bruker ASX Q Chromatographs PA 30 I IA CE R S T Time meters, impulsing meters and accessories I 2 I BT LV U V Special measuring equipment H 10.2 W X Accessories Y Z Main group 7K Electrical and electronic measuring instruments, analyzers, time meters MLFB manual 2011 136 7 L Sub group Catalog Product- responsibility A B C D E F Digital time switches and accessories I 2 I BT LV G Time switches with synchronous timer and reserve power H J K Withdrawable precision time switches L M N P Q Quarz-controlled time switches I 2 I BT LV R S Synchronous time switches I 2 I BT LV T U Socket-outlet time switches, coin-operated i-center time meters V W X Y Z Main group 7L Time switches MLFB manual 2011 137 7 M Sub group Catalog Product- responsibility A Measuring devices for liquid analysis PA I IA SC B Measuring devices for gas analysis PA I IA SC, I IS C Measuring devices for temperature and humidity MP 19, PA I IA SC, I IS D Indicating pressure gauges FI 01 I IA SC E Flow meters FI 01 I IA SC F Transducers for mechanical quantities FI 01 I IA SC Transducers with electric or pneumatic output G H Electromechanical weighting devices WT I IA SC, I IA CE J Measuring devices for mechanical quantities LT 500 I IS, I IA SC FI 01 K L Measuring devices for liquid levels FI 01 I IA SC M N P SIPROM Software for 7M. I IA SC Q R Liquid volume meters: cylindrical-piston meters FI 01 I IA SC S Liquid volume meters: special meters FI 01 I IA SC T Liquid volume meters: sliding-vane meters I IA SC U Liquid volume meters: food meters FI 01 I IA SC V Liquid volume meters: FI 01 I IA SC additional devices and accessories W X Y Spare parts MP 17 E I IA SC Z Main group 7M Measured-quantity-related measuring instruments and devices for process engineering MLFB manual 2011 138 7 N Sub group Catalog Product- responsibility A Analog indicator (panel) mounting MP 12 I IA SC B Analog limit monitors for (panel) mounting MP 12 I IA SC C Analog light-strip indicators for (panel) mounting MP 12 I IA SC D Elektrical recorders for (panel) mounting MP 20, I IA SC, I IS ART E F G Adapters MP 19, MP 17, I IA SC (neutral transducers and amplifiers) MP 19 E H Neutral power supply units, additional units MP 12, MP 20 I IA SC J Digital indicators, also for (panel) mounting MP 12 I IA SC K Digital limit monitors for (panel) mounting MP 12 I IA SC L Digital light-strip indicators for (panel) mounting MP 12 I IA SC M N P Q R S T U V W X Y Spare parts RT 20 E I IA SC Z Main group 7N Adapters, indicating instruments and recording instruments for process engineering MLFB manual 2011 139 7 P Sub group Catalog Product- responsibility A Auxiliary relays R 1.3 E D EA B C D Auxiliary relays, signalling relay combinations E D EA E F G Signalling relays R 1.3 E D EA H Thermal flasher relays E D EA J K Electronic presetting counter NS K I IA CE L Time-delay relays E D EA M N Time-delay relays with motor-drive mechanisms (earlier series) P Q Pneumatic time-delay relays R Time-delay relays with motor-drive mechanism NS K I IA CE S Electronic time-delay relays R 1.3 I IA CE T Electronic control blocks I IA CE U Electronic time-delay relays NS K I IA CE V Electronic time-delay relays I IA CE W X Time-delay relays, accessories and assembly NS K I IA CE kits for time-delay relays Y Z Main group 7P All-or-nothing relays MLFB manual 2011 140 7 R Sub group Catalog Product- responsibility A B C Current relays R 1.3 E D EA D E Voltage relays R 1.3 E D EA F G Voltage relays R 1.3 E D EA H J K L M Voltage relays R 1.3 E D EA N Directional relays E D EA P Frequency relays R 1.3, H 10.3 E D EA, I DT MC Q R Frequency relays (ripple control) Z 9 Landis & Gyr AG S T U V W Measuring relay combinations LSA2 E D EA X Accessories Z 9 Landis & Gyr AG Y Spare parts E D EA Z Main group 7R Measuring relays MLFB manual 2011 141 7 S Sub group Catalog Product- responsibility A Complete power-system protection systems LSA 2 E D EA B C Distribution Automation E D EA D Pilot supervisory modules for line differential R 1.1, LSA 2 E D EA E Fault locators E D EA F G Protection products/assemblies of Reyrolle E H J Independent time-overcurrent protection devices LSA 2, SIPROTEC E D EA K Dependent time-overcurrent protection devices R 1.2, LSA 2 E D EA L Distance protection devices E D EA M Additional devices for distance protection LSA 2 E D EA N Earth-fault protection devices R 1.1, LSA 2 E D EA P Directional overcurrent protection devices R 1.1 E D EA Q R Numerical Reyrolle protection relais E D EA S Busbar protection devices R 1.1, LSA 2 E D EA T Traction protection E D EA U V Power system protection devices for various tasks R 1.2, R 1.3, E D EA LSA 2 W Additional power system protection devices E D EA X Y Z Main group 7S Power-system protection, devices and instruments MLFB manual 2011 142 7SC Sub group Catalog Product- responsibility 0 1 2 3 4 5 6 7 8 Switch Controller E D EA 9 Sub group 7SC Distribution Automation MLFB manual 2011 143 7 T Sub group Catalog Product- responsibility A Tripping modules E D EA B C D Measurement-comparison modules E D EA E F Filter modules E D EA G Basic modules R 1.1 E D EA H J Current, current-time and E D EA current-voltage sensor modules K L Impedance, directional and measuring modules E D EA M Input converters E D EA N Converters, protective circuit-breakers, stabilizers R 1.3 E D EA P Frequency modules E D EA Q R Relay modules E D EA S Signalling and command modules E D EA T Timer modules E D EA U Voltage sensor modules E D EA V W Auxiliary modules E D EA X Y Z Main group 7T Withdrawable modules for protection equipment MLFB manual 2011 144 7 U Sub group Catalog Product- responsibility A Complete generator protection systems E D EA B C D Machine differential protection devices E D EA E Stator earth-fault protection devices E D EA F G Motor protection devices H J K L M Digital machine protection devices, LSA 2 E D EA multiple functions N P Electrical measuring devices for machines E D EA Q Transverse differential protection devices E D EA R Rotor earth-fault protection devices E D EA S Load-unbalance protection devices E D EA T Transformer differential protection devices E D EA U Excitation monitoring devices E D EA V Voltage-time protection devices E D EA W Additional devices for machine protection R 1.2, LSA 2 E D EA X Y Z Main group 7U Machine protection, devices and instruments MLFB manual 2011 145 7 V Sub group Catalog Product- responsibility A B C Earth-leakage monitors I 2, DA 94 I DT SD I BT LV D E Automatic synchronizers LSA 2 E D EA F Frequency balancers E D EA G H Relays and relay combinations W 21 E D EA for special applications J K Automatic reclosing devices LSA 2 E D EA L M Synchronous blocking devices, out-of-step R 1.1 E D EA N P Relay testing devices R 1.1, R 1.2, E D EA LSA 2 Q R Communication systems for NLT 3 E D EA power supply companies S Command control devices T U Changeover devices for station auxiliaries E D EA V Devices for special tasks DA 94, DA 69 E, I DT LD HA 20.2 W X Y Z Main group 7V Devices for miscellaneous tasks MLFB manual 2011 146 7 X Sub group Catalog Product- responsibility A Collars R 1.1, R 1.3, Z 9 E D EA, Landis & Gyr AG B Terminal covers C Connecting cables D Recorder chart paper Z 9 Landis & Gyr AG E Miscellaneous Z 9 Landis & Gyr AG F G Accessories and Spare parts for E D EA Protection and Reyrolle H Accessories for heliowatt products Landis & Gyr AG i-center J K Accessories for metering transformers and measuring devices L M N P Accessories for all-or-nothing relays R 1.1 bis R 1.3 E D EA (except for NZ manufacture) Q R Accessories for signalling relays R 1.1, R 1.2, E D EA (except for NZ manufacture) LSA 2 S Operator control software for protection LSA 2 E D EA equipment T Withdrawable accessories for protection systems R 1.2, LSA 2 E D EA U V Accessories for devices for miscellaneous tasks R 1.1, LSA 2, I 2 E D EA
W X Y Z Main group 7X Accessories for meters, protective devices and relays MLFB manual 2011 147 7 Z Sub group Catalog Product- responsibility A B Information and training for E D/E T E D EA power transmission and distribution trainings C Services for the E D/E T E D EA D E F G H J K L M N P Q R S T U V W X Y Z Main group 7Z Product-overlapping equipment of superordinate group 7 MLFB manual 2011 148 8 Main group A Switchgear, metal-enclosed, non-withdrawable, air-insulated B Switchgear, metal-enclosed with truck withdrawable, air-insulated C Switchgear with truck or withdrawable, cast-resin insulated D Switchgear, metal-enclosed, non-withdrawable, gas-insulated (SF6) E Switchgear for miscellaneous applications F Transformer substations G Insta distribution boards H Low-voltage distribution boards, box-frame type for/with non-withdrawable devices J Built-in devices for low-voltage distribution boards K Built-in devices for low-voltage distribution boards with non-withdrawable devices L Low-voltage distribution boards in rack-type assembly for/with non-withdrawable/removable devices M Low-voltage distribution boards, cabinet-type assembly, for/with non-withdrawable devices, emty cabinets N Low-voltage distribution boards, panel-type assembly with non-withdrawable devices P Low-voltage distribution boards with withdrawable devices, busbar trunking systems Q R Components of control-room equipment S Firedamp-protected and explosion-protected devices and equipment T Air compressors, accessories for compressed-air equipment control valves, switchgear interlocking devices, control cabinets U Components and drives for equipment and distribution boards V W Installation accessories for low voltage and high voltage, overhead line accessories and contact line accessories X Y Z Superordinate group 8 Factory assembled switchgear and controlgear Distribution MLFB manual 2011 149 8 A Sub group Catalog Product- responsibility A Switch-disconnector systems, single busbars HA 42 E D MV B Air-insulated high voltage system > 52kV E T C Switchgear cells, single-section, accessible from one side, single busbars, with included low-voltage cabinet D E Switchgear cells, single-section, accessible from two sides, single busbars F G Switchgear cells, single-section, accessible from two sides, single busbars, with included low-voltage cabinet H J Circuit-breaker systems, partially segregated, HA 34 E D MV single busbar K L Switchgear cell with top unit, accessible from both sides, single busbar M N Circuit-breaker systems, partially segregated, HA 34 E D MV double busbar P Q Single-cabinets R S Load-disconnector systems, equipment block T U V W X Accessories HA 20, HA 35 E D MV HA 41, HA 42 Y Z Main group 8A Switchgear, metal-enclosed, non-withdrawable, air-insulated MLFB manual 2011 150 8 B Sub group Catalog Product- responsibility A B C Circuit-breaker truck systems, E D MV single/double busbar D Circuit-breaker truck systems, E D MV segregated single/double busbar E F G Circuit-breaker truck systems, double busbar, with top disconnector-switch unit H Circuit-breaker truck systems, segregated, HA 41 E D MV double busbar, with top disconnector-switch unit J Withdrawable circuit-breaker systems, partially HA 25, HA 45 E D MV segregated, single/double busbar K Withdrawable circuit-breaker systems, HA 25, HA 28, E D MV metal-clad single/double busbar HA 27 L Withdrawable circuit-breaker systems, double busbar, with top disconnector-switch unit M Withdrawable circuit-breaker systems, metal-clad E D MV E D MV double busbar, with top disconnector-switch unit N P Q R S Standard racks for variable mounting of equipment T U V W X Accessories HA 25, HA 27, E D MV HA 28 Y Z Main group 8B Switchgear, metal-enclosed with truck withdrawable, air-insulated MLFB manual 2011 151 8 C Sub group Catalog Product- responsibility A B C D E F G H J K With drawable switch-disconnector systems, E D MV metal-enclosed (compact switch panels) L M N P Q R S T U V W X Accessories E D MV Y Spare parts E D MV Z Main group 8C Switchgear with truck or withdrawable, cast-resin insulated MLFB manual 2011 152 8 D Sub group Catalog Product- responsibility A Circuit-breaker systems, single-pole, HA 35 E D MV metal-clad, single busbar B Circuit-breaker systems, single-pole, HA 35 E D MV metal-clad, double busbar C Non-withdrawable switch-disconnector systems HA 35 E D MV up to 36 kV D E F G H Non-withdrawable switch-disconnector systems, HA 41 E D MV can be mounted side-by-side, maintenance-free J Switch-disconnector systems HA 45 E D MV K Components for 8DA to 8DJ E D MV L M High-voltage installations E T HS N High-voltage installations E T HS P High-voltage installations E T HS Q High-voltage installations E T HS R High-voltage installations E T HS S High-voltage installations E T HS T U V W Components for 8DM to 8DV X Accessories for switchgear with full insulation HA 35, HA 45, E D MV HA 41, HA 40 Y Z Main group 8D Switchgear, metal-enclosed, non-withdrawable, gas-insulated (SF6) MLFB manual 2011 153 8 E Sub group Catalog Product- responsibility A B C D E F G H J K L M Electromobility E D MV N P Q R S T U V W X Y Z Main group 8E Switchgear for miscellaneous applications MLFB manual 2011 154 8EM Sub group Catalog Product- responsibility 0 1 charging stations E D MV 2 3 4 5 6 7 8 9 Sub group 8EM Electromobility MLFB manual 2011 155 8 F Sub group Catalog Product- responsibility A Transformer load-centre substations I BT LV B Packaged transformer substations HA 51 E D MV C D E F Container stations, prefabricated HA 52 E D MV G Container switchgear E D MV H J K L M N P Q R S T U V W X Y Z Main group 8F Transformer substations MLFB manual 2011 156 8 G Sub group Catalog Product- responsibility A SIKUS cubicle-type distribution boards I 2 I BT LV B Small distribution boards, SIMBOX 63, I 2 I BT LV SIMBOX Universal, accessories C SIPRO cubicle-type distribution boards, accessories I 2 I BT LV D STAB wall-mounted distribution boards, accessories I 2, NS PS I BT LV E STAB-/SIKUS distribution boards for domestic I 2, NS PS I BT LV purposes 1) F STAB wall-mounted distribution boards, I 2, NS PS I BT LV SIKUS-/STAB-Universal, accessories G Control-cabinet system I 2, NS PS I BT LV (SIKUS 3200) H J Fuse and distributor boxes (insulating material) I 2 I MO, i-center K Alpha installation distributors I 2 I BT LV L Standard meter panels I BT LV, i-center M ALPHA basic distributor I BT LV N Built-on assemblies for accessories for I 2 I BT LV, i-center standard meter panels P Installation distributors I BT LV Q R Meter cabinets, accessories I 2 I BT LV S Distribution-cabinet system I BT LV T U V W X Y Z 1) for new use closed since 01.05.2004 Main group 8G Insta distribution boards MLFB manual 2011 157 8 H Sub group Catalog Product- responsibility A Accessories for insulation-enclosed/sheet-steel- LV I BT LV enclosed distribution boards B C Accessories for insulation-enclosed/sheet-steel- LV, NS PS I BT LV enclosed distribution boards D E Accessories for insulation-enclosed/sheet-steel- I 2 I BT LV enclosed distribution boards F G H EN systems, individual encapsulation components NV 21 I BT LV J K GT system L M N P Insulation-enclosed distribution system I 2 I BT LV Q R S Sheet-steel-enclosed distribution boards NV 21 I BT LV up to 2000 A, individual components T U Sheet-steel housing, accessories LV I BT LV V Empty housing made of sheet steel I BT LV W X Y Z Main group 8H Low-voltage distribution boards, box-frame type for/with non-withdrawable devices MLFB manual 2011 158 8 J Sub group Catalog Product- responsibility A B C D E F G H Accessories for insulation-enclosed/sheet-steel- LV I BT LV enclosed distribution boards J K Accessories for insulation-enclosed/sheet-steel- LV I BT LV enclosed distribution boards L M N P Q R S T U Accessories for sheet-steel-enclosed LV I BT LV distribution boards V W X Y Z Main group 8J Built-in devices for low-voltage distribution boards MLFB manual 2011 159 8 K Sub group Catalog Product- responsibility A Reserve desks for control rooms W 11 E (PG L6) B C D E F G Control-room writing desks H J Control pillars K L Light desks (system) M Control desks (system) N Individual components for light and control desks (system) P Q Stage lighting consoles R Stage lighting consoles S T Control and rudder stations U Control stations for conveyor systems V W X Y Z Main group 8K Built-in devices for low-voltage distribution boards with non-withdrawable devices MLFB manual 2011 160 8 L Sub group Catalog Product- responsibility A Reserve panels for free-standing rack and wall rack
B Built-in components for free-standing rack C Built-in components for wall rack D E F G H J Terminal blocks K L Racks for special tasks (ralays, contactors) M N P Q R S T U V Rack system for control units and controlled NV 21 I BT LV, I IA CE branch circuits, mounting plates with spacer rollers W Rack system for control units and controlled NV 21 I BT LV, I IA CE branch circuits, mounting plates with clips X X-system, individual components I BT LV, I IA CE Y Z Main group 8L Low-voltage distribution boards in rack-type assembly for/with non-withdrawable/removable devices MLFB manual 2011 161 8 M Sub group Catalog Product- responsibility A Cable distribution cabinets B Cable distribution cabinets for DIN pedestals I 2 I BT LV, i-center C Cabinet system 91 NV 21, NS PS I BT LV D E Unified cabinet system, individual components, NV 21, KT 93 I BT LV, I IS heat exchangers F Unified cabinet system, reserce cabinets NV 21, NS PS I BT LV G H J K Plug-in cabinet system L Low-voltage standard cabinets M Distribution boards for portable loads I BT LV, i-center N P Q R Universal accessories for cabinets and distribution NV 21 I BT LV (e.g. control cabinet cooling/heating equipment) S T SICUBE cabinet system I BT LV U Standard cabinet system I BT LV for switchgear and electronics V Cabinets containing components for different applications W X Y Z Main group 8M Low-voltage distribution boards, cabinet-type assembly, for/with non-withdrawable devices, emty cabinets MLFB manual 2011 162 8 N Sub group Catalog Product- responsibility A Reserve panels and cabinets for control rooms and W 11 E (PG L6) low-voltage control boards B Built-in components for 8NA1 control boards C D E F G H J K L M N P Q R S T U V W Single-front and double-front switchgear X Equipment modules Y Z Main group 8N Low-voltage distribution boards, panel-type assembly MLFB manual 2011 163 8 P Sub group Catalog Product- responsibility A B C D E F G Motor Control Center (MCC) H Overseas MCC I BT LV J K Low-voltage switchgear, cabinet-type distribution I BT LV boards L Busbar trunking systems for vertical installation, I 2 I BT LV insulation-enclosed, Sentron busbar trunking systems, Classic and accessories M Busbar trunking systems, steel-sheet-enclosed, I 2 I BT LV Sentron busbar trunking systems, Low Amp. and accessories, Sentron tap-off units for busbar trunking systems N P Q Low-voltage switchgears, energy distribution system I BT LV and motor control centre SIVACON R S SIVACON busbar trunking systems I BT LV 1) T Low-voltage switchgear, modular construction, I BT LV authorized manufacture system U Standard low-voltage switchgear, conductor I BT LV rail system 1) V Low-voltage switchgear, power distribution boards NS PS I BT LV W X MCC Siemens Canada Y Z 1) for new use closed since 01.05.2004 Main group 8P Low-voltage distribution boards with withdrawable devices, busbar trunking systems MLFB manual 2011 164 8 R Sub group Catalog Product- responsibility A Mosaic system M 15 (cross-bar system) B Mosaic system M 25 (cross-bar system) I IA CE C D E F G H J K L Control-room modules for centralized local W 21 E D EA control systems M Printed circuit boards for centralized local control W 21 E D EA N Complete standardized equipment for centralized local control P Q R S Mosaic system M 25 (plug-in system) W 12 I IA CE T Mosaic system M 19 (plug-in system) W 12 I IA CE U Mosaic system M 50 x 25 (plug-in system) W 12 I IA CE V W X Accessories for control-room equipment W 12, W 21 I IA CE E D EA Y Z Main group 8R Components of control-room equipment MLFB manual 2011 165 8 S Sub group Catalog Product- responsibility A Disconnectors B Circuit-breakers C Motor control units D Command and signalling units, control units, limit switches, timers and tripping devices E Equipment for distribution system construction F Transformer substations, lighting substations, lamps, transformers, power capacitors G Power-system protection devices, measuring devices, monitoring devices H Distribution materials and accessories, reserve housing J K Compact substations L Cable and protective-conductor bushings, sealing plugs M Winding devices, coking plant automation N High-voltage switching units P Pressurized equipment Q R S T U V W X Accessories I IS Y Spare parts I IS Z Main group 8S Firedamp-protected and explosion-protected devices and equipment MLFB manual 2011 166 8 T Sub group Catalog Product- responsibility A Air-compressors B Air-driers C Comprossed-air receivers D Accessories for compressed-air systems E D EA E F Control valves LSA 3.2 E D EA G Spare parts for compressed-air control units LSA 3.2 E D EA and valves which can no longer be supplied H Electropneumatic switchgear interlocking devices, LSA 3.2 E D EA valves J Electrical switchgear interlocking devices, LSA 3.2 E D EA valves K Electronic switchgear interlocking devices, LSA 3.1 E D EA valves L M Control cabinets for indoor and outdoor installation N P Q R S T U V W X Y Z Main group 8T Air compressors, accessories for compressed-air equipment control valves, switchgear interlocking devices, control cabinets MLFB manual 2011 167 8 U Sub group Catalog Product- responsibility A Torsional mechanisms, individual components NS E I BT LV of former types of construction B Torsional mechanisms with a permanent connected LV, NS E, I BT LV to the switchgear, individual and spare parts NS PS C Torsional mechanisms with releasable connection to LV, NS E, I BT LV the switchgear, drive mechanisms for direct surface- NS PS mounting, individual components and spare parts D E F G Shaft-operated mechanisms and spline-shaft- HA 39 E D MV operated mechanism for multi-voltage switchgear H Motor drive mechanisms for multi-voltage HA 39 E D MV switchgear, separately located J K L M N P Q R S Busbar adapter systems and accessories adaptable LV, NS PS I BT LV combinations of devices/motor branch circuits T Detachable level mechanisms NS E E U V Stirrup-operated mechanisms NS E E W Accessories for drive mechanisms HA 39 E D MV X Accessories E D SE Y Z Main group 8U Components and drives for equipment and distribution boards MLFB manual 2011 168 8 W Sub group Catalog Product- responsibility A Terminal blocks, including accessories I 2 I BT LV B Inscription plates (secured to wiring cables) I 2 I BT LV
C Sundries for auxiliary cables, NS E, NV 21 I BT LV Sundries for cable laying, busbar copper D Luminous annunciator panels, LV I IA CE multiple indicator lights, signal columns E F Expansion straps NV 21 I BT LV, I IA CD G Grounding material, grounding equipment NV 21 I BT LV, I IA CD H Terminal blocks I BT LV J K Bare cable accessories (tubing, rails, cables) L Contact line accessories I MO M Contact line accessories N P Q Supporting structures for indoor switchgear R Supporting structures for outdoor switchgear S Masts for overhead lines and contact lines T U V W X Y Z Main group 8W Installation accessories for low voltage and high voltage, overhead line accessories and contact line accessories MLFB manual 2011 169 9 Main group A Products and technical services of the Industrial Projects and Technical Services Group (I IS) B Products for logistics systems C Products and technical services of the Industrial Projects (E D/E T) D E F G H J K L Services of IA/DT/BT LV M N P Q R S T U V W X Y Z Superordinate group 9 Group-specific and user-specific technology Field services and workshop operations MLFB manual 2011 170 9 A Sub group Catalog Product- responsibility A Technical sevices I IS B Procucts I DT MC C Systems/modules I IS, I DT MC D Service and equipment service E Engineering, systems engineering, software I IS, I OS F Systems engineering products G Process informations and control systems (PICS) H Rolling mill equipment J K Systems engineering special products I IA CE L Components for automation solutions I IS M Systems/automation solutions N Training for engineering, assembly, startup and service P Plant and process simulation I IS Q R S T U V W X Y Z Main group 9A Products and technical services of the Industrial Projects and Technical Services Group (I IS) MLFB manual 2011 171 9 B Sub group Catalog Product- responsibility A Equipment and systems for production automation SICALIS and logistics B C D E F G H J K L M N P Q R S T U V W X Y Z Main group 9B Products for logistics systems MLFB manual 2011 172 9 C Sub group Catalog Product- responsibility A Network Consulting, Maintenance; E D SE Training; Projects; Energy Concepts B C D E F G H J K L M N P Q R S T U V W X Y Z Main group 9C Products and technical services of the Industrial Projects (E D/E T) MLFB manual 2011 173 9 L Sub group Catalog Product- responsibility A B C D Services of DT LD I DT LD E F G H J K L M N P Q R S T U V W X Y Z Main group 9L Services of IA/DT/BT LV MLFB manual 2011 174 9LD Sub group Catalog Product- responsibility 0 1 Services of DT LD CS I DT LD 2 3 4 5 6 7 8 9 Sub group 9LD Services of DT LD MLFB manual 2011 175