0% found this document useful (0 votes)
376 views3 pages

Etabs Modelling 6

The document provides guidelines for modeling a structure in ETABS, including: 1. Defining grids, units, material properties, sections for columns, beams, walls, and slabs. 2. Checking for irregularities according to code tables. 3. Specifying load cases including gravity and lateral loads.

Uploaded by

ashraf04_ce
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
376 views3 pages

Etabs Modelling 6

The document provides guidelines for modeling a structure in ETABS, including: 1. Defining grids, units, material properties, sections for columns, beams, walls, and slabs. 2. Checking for irregularities according to code tables. 3. Specifying load cases including gravity and lateral loads.

Uploaded by

ashraf04_ce
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ETABS MODELLING

1. DEFINITION : a. Define Grids and units : b. Define codes : Concrete frame design: ACI318-08/IBC2009 Shear wall design : ACI318-2009 c. Define Materials : Concrete C30/C40/C50 Mass = 2.4 Weight per unit volume = 24.6 Modulus of Elasticity = 25800/29800/33300 { ECO = 4700 fc } Poissons ratio =0.2 Coefficient of thermal expansion = 9.90 E-06 Specified concrete comp strength, fc = 30 MPa / 40 MPa / 50 MPa Bending Reinf. Yield stress, fy = 400 MPa Shear . Yield stress, fys = 400 MPa d. Columns and beams Concrete columns: - Sizes : appropriate sizes - Material : C30/C40/C50 - Modification factors : Moment of inertia about axis 2 = 0.7 Moment of inertia about axis 3 = 0.7 - Reinforcement data : Design type = column Cover = 40 mm Reinf. To be designed And later Rein. To be checked Concrete beams: - Sizes : appropriate sizes - Modification factors : Moment of inertia about axis 2 = 0.35 Moment of inertia about axis 3 = 0.35 - Reinforcement data : Design type = beam Cover = 40 mm Reinf. For ductile beams to be putted later after design e. Walls and Slabs Concrete Walls: - Sizes : appropriate sizes - Material : C40

Type : shell Modification factors : Bending m11 = 0.7 Bending m22 = 0.7 Bending m33 = 0.7 Concrete Slabs: - Sizes : appropriate sizes - Material : C40 - Type : shell - Modification factors : Bending m11 = 0.25 Bending m22 = 0.25 Bending m33 = 0.25 The modification factors for columns and beams can be defined later by selecting the elements

f.

Loadings

Static loads Type Dead Super dead Live Snow Multiplier 1 0 0 0

SELFW SDL Live Snow

Own weights Finishes, landscape As per code,... Snow loads

Static Lateral loads Type Quake Quake Quake Quake WIND WIND Multiplier 0 0 0 0 0 0 Auto Lateral Load UBC97 UBC97 UBC97 UBC97 UBC97 UBC97 Direction Earth. dir X + Ecc. Y Earth. dir X + Ecc. Y Earth. dir Y + Ecc. X Earth. dir Y - Ecc. N Wind dir X Wind dir Y

EQXP EQXN EQYP EQYN WINX WINY

Earthquake lateral load input details: EQXP X dir + Eccen Y 0.05 0.02 ALL EQXN X dir - Eccen Y 0.05 0.02 ALL EQYP Y dir + Eccen N 0.05 0.02 ALL EQYN Y dir - Eccen Y 0.05 0.02 ALL

Direction Eccentricity Time period Story range

Factor R (*) Soil profile Zone factor Na (if zone 4)(**) Nv (if zone 4)(**) Factor I

5.5 SD 0.4 1 1 1

5.5 SD 0.4 1 1 1

5.5 SD 0.4 1 1 1

5.5 SD 0.4 1 1 1

(*) this factor, R, represents the type of the lateral resisting system for structure, and should be adjusted after verification of results. (**) Na & Nv are used only in seismic zone 4.

Wind lateral load input details: WINX WINY 0 90 0.8 0.8 From GF to Roof 1.5 1.5 100 100 C C 1 1

Direction angle Windward, Cq Exposure height Parapet height Wind Speed Exposure type Importance factor I

g. Define Mass source (1630.1): Mass Source if Residential, Wseismic = (1) SelfW + (1) SDL If Storage, Wseismic = (1) SelfW + (1) SDL + (0.25) Live

2. IRREGULARITY CHECK : Vertical Irregularities (Table 16-L) and Plan Irregularities (Table 16-M)

Method of analysis should be selected

Static (1629.8.3), or Dynamic (1629.8.4)

3.

Redundancy factor :