Air Charge-Air Cooling: Diesel Generator Set

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

A TOGNUM GROUP BRAND

DIESEL GENERATOR SET AIR CHARGE-AIR COOLING


715 kVA /50 Hz /Standby (Fuel-Optimized) 380 - 415V
(Reference DP650D5S-Fuel Optimized and DP650D5S-Exhaust Optimized for Prime Rating Technical Data)

BENEFITS
// // // // //

Low installment cost Best fuel consumption values Long maintenance intervals High-efciency components Best-in-class reliability and availability

SYSTEM RATINGS
Standby
Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model Temp Rise Connection DS715D5S 380V 3 0.8 50 572 715 1086 1450 573RSL7733 150 C/40 C 4 LEAD WYE DS715D5S 400V 3 0.8 50 572 715 1032 1600 573RSL7733 150 C/40 C 4 LEAD WYE DS715D5S 415V 3 0.8 50 572 715 995 2000 573RSL7733 150 C/40 C 4 LEAD WYE

* Power available up to 40C / 400 m

CERTIFICATIONS AND STANDARDS


//

Engine-generator set is designed and manufactured in facilities certied to standards ISO 9001:2008 and ISO 14001:2004 Performance Assurance Certification (PAC) - Engine-Generator Set Tested to ISO 8528-5 for Transient Response - Veried product design, quality and performance integrity - All engine systems are prototype and factory tested

//

Power Rating - Permissible average power output during 24 hours of operation is approved up to 85%.

//

// / / 50 Hz 715 kVA

STANDARD FEATURES*
// // // // // // // //

//

The generator set complies to G2 Engine-generator set tested to ISO 8528-5 for transient response Accepts rated load in one step per NFPA 110 All engine-generator sets are protoype and factory tested MTU Onsite Energy is a single source supplier Global Product Support 2 Year Standard Warranty 12V1600 Diesel Engine - 21.0 Liter Displacement - Common Rail Fuel Injection - 4-Cycle Complete Range of Accessories

//

Permanent Magnet Generator (PMG) - Brushless, Rotating Field Generator - 300% Short Circuit Capability - 2/3 Pitch Windings // Cooling System 50 C - Integral Set-Mounted - Engine Driven Fan // Terminal Box

STANDARD EQUIPMENT*
//

Engine

//

Generator

Air Cleaners Oil Pump Oil Drain Extension & S/O Valve Full Flow Oil Filters Closed Crankcase Ventilation Jacket Water Pump Thermostat Exhaust Manifold - Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 24V Governor Electronic Isochronous Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 24V Flexible Fuel Connectors Fuel System: Common Rail

//

Customer Interface

Smart Connect

NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting VDE 0530, IEC 34.1, BS5000, CSA C22.2-100, AS1359 Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter 4 Pole, Rotating Field 150 C Maximum Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-Phase Voltage Sensing 0.25% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content Insulation Class H Protection Class IP20

* Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional congurations.

// / / 50 Hz 715 kVA

APPLICATION DATA
//

Engine
MTU 12V1600G80F 4-Cycle 12-V 21 (1,281) 12 (4.72) 15 (5.91) 17.5:1 1,500 Electronic Isochronous 634 (850) 0.25% Dry

//

Fuel Consumption
STANDBY 143.1 (37.8) 107.1 (28.3) 74.6 (19.7)

Manufacturer Model Type Arrangement Displacement: L (Cu In) Bore: cm (in) Stroke: cm (in) Compression Ratio Rated RPM Engine Governor Max Power: kWm (bhp) Speed Regulation Air Cleaner

At 100% of Power Rating: L/hr (gal/hr) At 75% of Power Rating: L/hr (gal/hr) At 50% of Power Rating: L/hr (gal/hr)

//

Cooling - Radiator System


STANDBY 50 (122) 0.125 (0.5) 433 (115) 255 (14,501) 133 (7,563) 68.1 (3,873) 65 (17,2) 41 (10,8) 95 (203)

//

Liquid Capacity (Lubrication)


73 (19.3)

Total Oil System: L (gal)

Ambient Capacity of Radiator: C (F) Max. Restriction of Cooling Air, Intake, and Discharge Side of Rad.: kPa (in. H20) Water Pump Capacity: L/min (gpm) Heat Rejection to Coolant: kW (BTUM) Heat Rejection to After Cooler: kW (BTUM) Heat Radiated to Ambient: kW (BTUM) Engine Coolant Capacity: L (gal) Radiator Coolant Capacity: L (gal) Coolant to Cooler Temperature: C (F)

//

Electrical
//

Air Requirements
STANDBY 45 (1,589) 803 (28,350)

Electric Volts DC Cold Cranking Amps Under -17.8 C (0 F)

24 1,000 Aspirating: *m3/min (SCFM) Air Flow Required for Rad. Cooled Unit: *m3/min (SCFM) Remote Cooled Applications; Air Flow Required for Dissipation of Radiated Gen-set Heat for a Max of 25 F Rise: *m3/min (SCFM) * Air density = 1.184 kg/m3 (0.0739 lbm/ft3)
//

//

Fuel System
M 20x1.5 Male/#10 JIC Female M 14x1.5 Male/#6 JIC Female 5 (16) see MTU Fluids & Lubrication Spec. 341.8 (90.3)

Fuel Supply Connection Size Fuel Return Connection Size Maximum Fuel Lift: m (ft) Recommended Fuel Total Fuel Flow: L/hr (gal/hr)

247 (8,734)

Exhaust System
STANDBY 485 (905) 120 (4,238) 15 (60.2)

Gas Temp. (Stack): C (F) Gas Volume at Stack Temp: m3/min (CFM) Maximum Allowable Back Pressure: kPa (in. H20)

// / / 50 Hz 715 kVA

WEIGHTS AND DIMENSIONS

Drawing above for illustration purposes only, based on standard open power 400 volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specic template drawings.

System Open Power Unit (OPU)

Dimensions (L x W x H) 3,738 x 1,902 x 2,137 mm (147.13 x 74.875 x 84.13 in)

Weight (dry/less tank) 4,545 kg (10,020 lbs)


MTU Onsite Energy. | Subject to alteration due to technological advances. | 3236011 | 1/11 | VMC 2011-12.

Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specic engine-generator set.

SOUND DATA
Unit Type Level 0: Open Power Unit (dBA) Standby Full Load C/F

Sound data is provided at 7 m (23 ft). Engine-generator set tested in accordance with ISO 8528-10 and with innite exhaust.

EMISSIONS DATA
NOx + NMHC C/F CO C/F PM C/F

RATING DEFINITIONS AND CONDITIONS


//

Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514, AS 2789, and DIN 6271. // Deration Factor: Altitude: Consult your local MTU Onsite Energy Distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Distributor for temperature derations.

Materials and specications subject to change without notice. C/F = Consult Factory/MTU Onsite Energy Distributor
// Tognum Group Companies: Europe / Mediterranean / CIS / Middle East / Africa / MTU Friedrichshafen GmbH / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax +49 7541 90 7084 / [email protected] // North East Asia / South East Asia / China / Australia / Pacic / Tognum Asia Pte. Ltd. / 1 Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 6861 5922 / Fax + 65 6861 3615 / [email protected] // USA / Canada / Mexico / Latin America / MTU Onsite Energy / 100 Power Drive / Mankato, MN 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / [email protected] //www.mtu-online.com

You might also like