Features: Econoline
Features: Econoline
Features: Econoline
Unregulated Converters
Description
Custom Solutions Available 1kVDC & 2kVDC Isolation No Extern. Components Required UL94V-0 Package Material No Heatsink Required Efficiency to 85%
ECONOLINE
DC/DC-Converter
with 3 year Warranty
The RN series of compact 1.25W single output converters are especially useful when more than 1W of power is required, but there are space restrictions than make a 2W converter unsuitable. The converter series feature an industrial ambient temperature operating range of -40C ~ +85C without derating and up to 100C ambient temperature with derating. Options include 1kVDC or 2kVDC isolation and continuous short circuit protection (/P).
Selection Guide
Part Number DIP6 RN-xx3.3S RN-xx05S RN-xx07S RN-xx09S RN-xx12S RN-xx15S RN-xx24S Input Voltage (VDC) 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 Output Voltage (VDC) 3.3 5 7 9 12 15 24 Output Current (mA) 378 250 180 140 104 84 52 Efficiency (%) 70 70-72 72-75 75-80 79-82 80-84 80-85 Max. Capacitive Load(1) 2200F 1000F 1000F 1000F 470F 470F 220F
x = Input Voltage (other input and output voltage combinations available on request) * add Suffix P for Continuous Short Circuit Protection, e.g. RN-0505S/P, RN-0505S/HP
2011/65/EU 6/6
RoHS
EN-60950-1 Certified
Specifications (Core Operating Area)
Input Voltage Range Output Voltage Accuracy Line Voltage Regulation Load Voltage Regulation (10% to 100% full load) Output Ripple and Noise (20MHz limited) Operating Frequency Efficiency at Full Load Minimum Load = 0% Isolation Voltage Isolation Voltage Isolation Capacitance Isolation Resistance Short Circuit Protection Operating Temperature Range (free air convection) Storage Temperature Range Relative Humidity Package Weight Packing Quantity MTBF (+25C) (+85C) 1.9g 39 pcs per Tube
Detailed information page 266
10% 5% 3.3V output types 5V output type 9V, 12V, 15V, 24V output types 1.2% typ. / 1.4% max. 20% max. 15% max. 10% max. 75mVp-p max. 50kHz min. / 100kHz typ. / 105kHz max. 70% min. / 75% typ. Specifications valid for 10% minimum load only. (tested for 1 second) (rated for 1 minute) H-Suffix H-Suffix (tested for 1 second) (rated for 1 minute) 1000VDC 500VAC / 60Hz 2000VDC 1000VAC / 60Hz 30pF min. / 95pF max. 10 G min. 1 Second -40C to +85C (see Graph) -55C to +125C 95% RH
RN
Derating-Graph
(Ambient Temperature)
100 80
60 40 30 20 0
85 Operating Temperature C
-40
50
100
150
955 x 103 hours 132 x 103 hours REV: 0/2013 Refer to Application Notes E-81
www.recom-international.com
ECONOLINE
DC/DC-Converter
Typical Characteristics
RN Series
RN-xx12S
Efficiency / Load
100 100 80 60 40
RN-xx05S
Efficiency / Load
100 80 60 40
RN-xx15S
Efficiency / Load 0515
80 60
1205
0505
0512
1212 Efficiency %
40 20 0
1215
Efficiency %
Efficiency %
20 0
20 0
0%
20%
40%
60%
80%
100%
0%
20%
40%
60%
80%
100%
0%
20%
40%
60%
80%
100%
Deviation / Load
25.000 20.000 25.000
Deviation / Load
25.000 20.000 20.000
Deviation / Load
0505
0512
0515
1205
1212
1215
80%
100%
80%
100%
80%
100%
Notes Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter. Report: SPCLVD1109103 EN60950-1:2006 + A12:2011 Certifications EN General Safety
RN
3.25
7.62
5.08
2.54
E-82
REV: 0/2013
www.recom-electronic.com