Trox - Ark2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Construction

Type ARK2
ARK2 Casing formed from galvanised sheet steel; casing in stainless steel on request Aluminium blades Blade shafts stainless steel Bearing from composite material with antifriction lining of PTFE/Pb (maintenance-free) Seals made of neoprene, temperature resistant up to 80 C Opening pressure difference 50-1000 Pa for dampers up to a width of 600 mm Opening pressure difference max. 600 Pa for dampers with a width greater than 600-1200 mm The required opening pressure difference must be specified when ordering Construction variant ARK2-G As for type ARK2, but both flanges drilled

Surface finish
Powder coating P1 Standard RAL shades: RAL RAL RAL RAL Other shades on request
* GE = Gloss level

9010-GE50*, RAL 9006-GE30*, 9001, RAL 9002, RAL 9003, 9005, RAL 9016, RAL 7001, 7035 all GE70*

Casing Blade Seal Stop angle

Blade shaft Bearing Permanent magnet

Type ARK2

max. 235

38

180

Damper locked

Damper unlocked

Standard Sizes Installation Details


Standard sizes
B in mm
200 400 600 800 1000 1200

Flange drilling details


B 20 20

H in mm
345 675 1005 1335 1665 1995

Number of Number of holes Number of blade coupling per Bper Hblades sections * dimension dimension
1 2 3 4 5 6 1 1 2 2 2 2 4 5 7 8 10 4 6 9 12 14 17
* only with type ARK

even number of holes


H 9.5

Any combinations of dimensions B x H listed above can be supplied. Intermediate dimensions on request.

Inlet cross-section A in m2
H in mm 200
345 675 1005 1335 1665 1995 0.069 0.135 0.201 0.227 0.333 0.399

400
0.138 0.270 0.402 0.454 0.666 0.798

B in mm 600 800
0.207 0.405 0.603 0.681 0.999 1.197 0.276 0.540 0.804 0.908 1.332 1.596

odd number of holes


1000
0.345 0.675 1.005 1.135 1.665 1.995

1200
0.414 0.810 1.206 1.362 1.998 2.394

Hole pitch B- and H-dimensions = 125 mm

Installation on surface of wall opening

Installation between ventilation ducts

H + 20 / B + 20

H/B

Type ARK2 shown Installation opening without masonry subframe B / H

Type ARK2 shown

Detail X
Special screw

Masonry subframe
Construction with one masonry subframe Code 22

For construction using masonry subframe, the casing flanges are drilled on both sides. By using special screws in the masonry subframe, the non return damper or pressure relief damper can easily be demounted or mounted even when subframe is fitted in the wall. Scope of supply masonry subframe: Galvanised angle steel masonry subframe 35/35/3; builders cleats (screw-on type), special screws, screws, nuts and washers made of galvanised steel (installation on site, by others).

H/B

Masonry subframe

H/B

Technical Data
Nomenclature
B H A v pt in mm: Width in mm: Height in m2: Inlet cross-section (see page 5) in m/s: Air velocity with damper opened based on inlet cross-section A in Pa: Total pressure drop (duct mounting) with damper open in l/s: Leakage volume flow rate in m3/h: (independent of width B) in m3/h: Resulting volume flow

Example 1
Data given: Non return damper type ARK B = 600 mm, H = 1005 mm p D = 2000 Pa, v = 7 m/s Horizontal installation orientation Required: Total pressure drop pt Leakage volume flow V L Result: (from diagram) pt = 100 Pa V = 1.3 l/s (4.7 m3/h) L

pD in Pa: Pressure difference with damper closed VL

Example 2
Data given: Pressure relief damper type ARK2 1000 Pa B = 600 mm, H = 1005 mm, A = 0.6 m2 p = 1000 Pa, v = 2 m/s Required: Total pressure drop pt with damper open Resulting volume flow V Result: pt = 50 Pa (from diagram) V = v A 3600 = 2 0.6 3600 = 4320 m3/h

p in Pa: Opening pressure difference

Pressure drop type ARK ARK1


140

Pressure drop type ARK2


100 1 1 80

120

100 Pa 80 60 Pa 60 pt pt 40 2 20 20 0 0 2 4 v m/s 6 8 10 40

m/s v

Leakage volume flow type ARK ARK1


H 345 mm 675 5000 1005 1335 1665 1995

Installation orientation
1 horizontal duct (graph 1) 2 vertical duct (graph 2) 3 horizontal duct

Pa 3000

pt

pt

4000

pD

2000

1000

Installation orientations
Diagram Type ARK 1+2 3 Type ARK1 1+2 3 Type ARK2 1
0.5 2 1 4 . VL 1.5 l/s 2 2.5 10 3 12 3.5

500

Pressure drop Leakage volume flow

6 m3/h 8

pD