LNL TS 2220
LNL TS 2220
LNL TS 2220
LNL-2220
Overview
The LNL-2220 Intelligent Dual Reader Controller (IDRC) by Lenel provides a single board solution for interfacing one or two doors to an OnGuard system. In addition, other I/O and reader interface modules can be added on the LNL-2220s downstream port to expand its capabilities. The LNL-2220 revolutionizes access control system architecture by allowing Ethernet connection directly from an entry location to the OnGuard server, while still providing the security, functionality, and modularity of Lenels proven hardware platform. The LNL-2220 is scalable for any access control application, from the most basic to the most sophisticated. In the event of communication loss, the LNL-2220 allows nearly all local functionality to continue unimpaired until the server connection is restored. Utilizing its native Ethernet communications and an advanced 32bit processor, the LNL-2220 can communicate upstream to the host computer through its Ethernet port (with a throughput up to eight times greater than the fastest serial connections), or at up to 115.2 Kbps using RS-232 communication directly or through an external dial-up modem. The LNL-2220 can store up to 250,000 cardholders in non-volatile flash memory, and supports selective download for larger cardholder databases. The downstream RS-485 two-wire port can be used to connect up to 32 devices (maximum 64 doors). Two on-board reader ports support Data1/Data0, Clock/Data, Bioscrypt RS-485 readers and the bidirectional RS-485 Open Supervised Device Protocol (OSDP) communications. Each LNL-2220 supports up to eight different card formats. The LNL-2220 includes eight inputs that support normally open, normally closed, supervised, and unsupervised circuits. In addition, four output relays support fail-safe or fail-secure operation.
LNL-2220
TCP/IP NETWORK
LNL-1300
LNL-1320
LNL-1100
LNL-1200
Motion Sensor
Option 2.1 Option 2.2
Alarm
-OR-
Reader
Reader
Reader
Reader
Reader
Reader
Reader
Controller Features
LNL-2220 6 MB On-board flash memory available for cardholder & asset database, 50,000 event battery backed RAM for event log Dial-Up Modem LNL-56KEXT LNL-DC336K 56 K external modem with cables 12 VDC-powered/33.6 K external modem
Specifications
Primary Power (DC or AC) DC input: AC input: Memory and Clock backup Communication Ports Primary (Ethernet) Port: Alternate Upstream Port 1: Downstream Port 2: Inputs Tamper and Power Fail Monitors: Door position, REX, and AUX: Outputs Relay outputs: 4 Form-C 5 A at 30 VDC relay outputs: 2 strike, 2 auxiliary Unsupervised, dedicated 8, each programmable as normally open or normally closed, supervised or unsupervised circuits 10/100Base-T Ethernet high-speed port RS-232 9600 to 115.2 Kbps async RS-485 (2-wire) 9600 to 38.4 Kbps async Humidity: Mechanical Dimensions: Weight: Approvals Supported Readers Approvals: 6 x 5 x 1 in. (152 x 127 x 25 mm) 8 oz. (230 g) nominal UL 294, CE-marked, RoHS compliant Schlage Wireless - WA 5296, WA 5696, WA 5694, WA 993, WRI, WPR FCC Part 15, CE, RoHS, UL 294, UL 294, UL 1076, ULC CSA-C22.2, CAN/ULC-S319-05, cUL/ORD-C1076 Environmental Temperature: Operating: 32 to 158 F (0 to +70 C) Storage: -67 to 185 F (-55 to +85 C) 0 to 95% RHNC * The LNL-2220 is for use in low voltage, power-limited, class 2 circuits only. 12 or 24 VDC 15%. 500 mA maximum 12 VAC 15%. 400 mA RMS Reader Port Compatibility 3 V lithium, type BR2325, BR2330, CR2330 Reader Power DC output: 12 VDC, 125 mA regulated when 24 VDC powered, or 12 to 24 VDC 125 mA current limited Wiegand Data1/Data0, Magnetic Clock/Data, F/2F single-wire protocol, Bioscrypt RS-485, OSDP (Open Supervised Device Protocol RS-485)
lenel.com
(866) 788-5095
Specifications subject to change without notice. 2013 Lenel Systems International, Inc. All rights reserved. All other trademarks and copyrights are the property of their respective owners.
LNL_TS_2220_102813