0% found this document useful (0 votes)
429 views2 pages

MQ307A

The MQ307A is a tin dioxide semiconductor gas sensor that detects carbon monoxide (CO) using a mini-bead sensing element and periodic temperature change operation. This provides the sensor with high sensitivity, selectivity, and resistance to humidity effects. The sensor structure uses a mini bead sensing element embedded in a metal housing with double stainless steel mesh. It operates by changing the sensor signal according to temperature-dependent characteristics measured at high and low temperatures to selectively detect methane and CO.

Uploaded by

Farshad yazdi
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
429 views2 pages

MQ307A

The MQ307A is a tin dioxide semiconductor gas sensor that detects carbon monoxide (CO) using a mini-bead sensing element and periodic temperature change operation. This provides the sensor with high sensitivity, selectivity, and resistance to humidity effects. The sensor structure uses a mini bead sensing element embedded in a metal housing with double stainless steel mesh. It operates by changing the sensor signal according to temperature-dependent characteristics measured at high and low temperatures to selectively detect methane and CO.

Uploaded by

Farshad yazdi
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HANWEI ELETRONICS CO.,LTD MQ-307A http://www.hwsensor.

com

MQ307A CO GAS SENSOR

The MQ307A is a tin dioxide semiconductor gas sensor


which has an excellent performance in CO detection. Using a
mini-bead type sensing element with a periodic temperature
change operation method, high sensitivity, selectively,
small effect from humidity and other remarkable
characteristics have been achieved. The MQ307A realizes
the development of reliable CO detection devices.

Structure
Gas sensitive semiconductor material is a mini bead type and a heater coil
and electrode wire are embedded in the element. The sensing element is
installed in the metal housing which uses double stainless steel mesh
(100mesh) in the path of gas flow.

Operating conditions
When the sensor is operated with high/low periodic operation (Fig 2), sensor
signal changes according to the temperature dependencycharacteristics. By
detecting the sensor signal at sufficient timings (at a high temperature for
methane and at a low temperature for CO), selective detection of both
methane and CO has been achieved. Fig 3 shows the standard operation
circuit and FIg 4 shows the sensitivity characteristics of the MQ307A at low
temperature.

TEL: 86-371-67169070 67169080 FAX: 86-371-67169090 E-mail: [email protected]


HANWEI ELETRONICS CO.,LTD MQ-307A http://www.hwsensor.com

A.Standard Working Terms


Symbol Parameter Technical Terms Remarks
VH(H) Heater Voltage(High) 0.90V ± 0.10V AC or DC
VH(L) Heater Voltage(Low) 0.2 V± 5% DC (polarity is important)
VC Circuit Voltage ≤6V
RL Load Resistance Adjustable(> 1 KΩ) P S < 10 mW
RH Heating Resistance 3.8 3.8 Ω ± 0.5 Ω Room Temperature
TH (H) Heating Time(High) 30sec ± 5 sec
TH (L) Heating Time(Low) 120 sec ± 10sec
DT (L) Sampling Time(Low) < 1 sec At the ending of Low Voltage heating
I (H) Heating Current(Low) ≤ 120 mA VH=0.9V
I (L) Heating Voltage(Low) 40±5mW VH=0.2V
PS power ≤10 mW P S = (V C - V RL ) 2/ R S
PH Heating consumption Less than 100mw
B.Environment Conditions
Symbol Parameter Technical Terms Remarks
o o
Tao Using temperature -20 C to 50 C
o o
Tas Storage -20 C to 70 C Recommended Application Ranges
Temperature
RH Relative Humidity ≤ 95% RH
(O2) Oxygen 21%±1%(Standard terms) Not less than 18%
Concentration 02 Influence sensor performance
C. Sensitivity Characteristics
Model MQ-307A
Symbol Parameter Technical terms Remarks
Rs Sensitive Resistance (20kΩto 200 kΩ ) In 200 ppm CO
(30-100) Resistance Proportion 1.05 to 2.1 Rs (30 ppmCO) / Rs (100 ppmCO)
(100-300) Resistance Proportion 0.75 to 1.2 Rs(300 ppmCO) /Rs(100ppmCO)
Standard Testing Terms: Temperature : 20 C ± 2 C
o o
V C : 5.0 V 1%
Humidity: 65%± 5% V H : 0.9 V ± 1% R L : 50K Ω ±5%
Preheating Time:more than 48 hours

TEL: 86-371-67169070 67169080 FAX: 86-371-67169090 E-mail: [email protected]