SITEX Directional Eng

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

DIRECTIONAL UNITS

SITEX & SITEXS

PORTABLE X-RAY GENERATOR


Increase the reliability of on-site X-ray techniques while decreasing their costs
OUR CHALLENGE...
To increase the reliability of on-site X-ray techniques while decreasing their costs To successfully meet this challenge, ICMs engineers have worked at improving upon what we consider to be largely tried and tested techniques. The technological options were determined at each development stage on the basis of quality, general reliability and the need to substantially increase the life of the X-ray tube. If you are already impressed with the reliability of the SITEX and SITEXS generators, we are confident that you will be even more impressed with their outstanding performance levels. These performance levels will enable you to take advantage of the most favorable overall operating costs available to the market.

A SIMPLE & EFFECTIVE PRINCIPLE


All SITEX and SITEXS units contain a rod anode. This is the focal spot that is outside the SF6-insulated high-voltage generator. As maximum advantages are derived from this ideal configuration, for one and the same thickness, the volume of lead required for standard radiation protection is considerably reduced. Consequently, the reduced weight that is achieved makes it possible for further investments to be made in the quality and general improvement of the level of performance (robustness, cooling, accessories etc). We can confirm that SITEX and SITEXS are among the lightest portable X-ray generators available to the market.

PERFORMANCE
A high-efficiency heat exchanger has been developed in collaboration with the Institute of Thermo-mechanics at the University of Liege. This results in the possibility of a 100% working cycle under completely safe conditions, whilst simultaneously reducing the anode temperature by 50%.

DETAILS THAT SIMPLY IMPROVE EVERYTHING


The SITEX directional generators are equipped with an internal carousel. This contains a lead cap and 4 diaphragms that are calibrated for the films that are used the most. Ensuring protection from accidental on-site losses and weighing in total a mere 1.0 kg, this very practical device replaces approximately 20 kg of fragile and space-consuming accessories. The carousel fitted on the SITEXS provides the same features and is equipped with a laser pointer. To ensure ease of handling, direct access has been arranged on the moving part.

MEASUREMENT & CONTROL


Representing another first in a portable, the SITEX and SITEXS have a facility to ensure the direct and true measurement of the high voltage. This essential information enables the control system to guarantee the stability and reproducibility of the radiological parameters based on true high-voltage values rather than merely estimating an HV value based on dose output.

SITEXS, THE EXTRA-SMALL


These XS X-ray generators are in fact reduced versions of the corresponding SITEX units available in 200, 225 and 250 kV versions and provide considerably more compactness.

www.icmxray.com/ndt

SITEX & SITEXS directional technical specifications :


SITEX& XS DIRECTIONAL
Output voltage range Output voltage selection step Tube current range Tube current range at full output Tube current selection step Radiation geometry Maximum useful angle of X-ray beam Dimension of optical focal spot Inherent ltration Carrousel of internal diaphragms with lead cap Working cycle at 40C ambient temp. Operating temperature range Storage temperature range SF6 insulation pressure at 20C Cooling fan supply voltage Weatherproof level Penetration into steel at max power (FFD=700mm/Film D7pb/D=1.5/T=20 min) Guard rings Position of interconnection socket Number of telescopic centring device (FFD=700mm) Max. leakage dose at 1m according to DIN at full output Microcontroller HT measurement circuit (kV and mA) Overall dimensions Total weight without guard rings choice mSv/h mm kg yes Radial 2.5 yes 250 x 573 9.5 yes Axial/Radial 1 2.5 yes 346 x 771 28 yes Axial/Radial 1 10 yes 346 x 771 28 yes Axial/Radial 1 10 yes 346 x 771 28 yes Axial/Radial 1 10 yes 346 x 831 31 yes Axial/Radial 1 10 yes 346 x 831 31 yes Axial/Radial 1 10 yes 400 x 930 46 yes Axial/Radial 1 (laser) 2.5 yes 305 x 718 19 yes Axial/Radial 1 (laser) 10 yes 305 x 718 19 yes Axial/Radial 1 (laser) 10 yes 305 x 718 19

UNITS
kV kV mA mA mA () mm mm % C C kg/cm2 VDC mm Fe

D1802
60 to 180 1 1 to 3 2 0.1 Directional 60 x 40 0.8 x 0.8 Equiv. 3.5 (Al) no 50* -25 to +70 -40 to +80 5.0 24 IP65 24

D2008
70 to 200 1 1 to 8 8 0.1 Directional 60 x 40 2.5 x 2.5 2.5 (Al) + 0.4 (Ni) yes (4 + 1) 100 -25 to +70 -40 to +80 5.0 24 IP65 41

D2258
70 to 225 1 1 to 8 8 0.1 Directional 60 x 40 2.5 x 2.5 2.5 (Al) + 0.4 (Ni) yes (4 + 1) 100 -25 to +70 -40 to +80 5.0 24 IP65 49

D2506
70 to 250 1 1 to 6 6 0.1 Directional 60 x 40 2.5 x 2.5 2.5 (Al) + 0.4 (Ni) yes (4 + 1) 100 -25 to +70 -40 to +80 5.0 24 IP65 54

D3006
90 to 300 1 1 to 6 6 0.1 Directional 60 x 40 2.5 x 2.5 2.5 (Al) + 0.4 (Ni) yes (4 + 1) 100 -25 to +70 -40 to +80 5.0 24 IP65 70

D3206
90 to 320 1 1 to 6 6 0.1 Directional 60 x 40 2.5 x 2.5 2.5 (Al) + 0.4 (Ni) yes (4 + 1) 100 -25 to +70 -40 to +80 5.0 24 IP65 76

D3605
120 to 360 1 1 to 5 5 0.1 Directional 60 x 40 2.6 x 2.6 2.5 (Al) + 0.4 (Ni) yes (4 + 1) 60 -25 to +70 -40 to +80 5.0 24 IP65 82

XS-D2004
70 to 200 1 1 to 4 4 0.1 Directional 60 x 40 2.5 x 2.5 0.4 (Ni) yes 100 -25 to +70 -40 to +80 5.0 24 IP65 37

XS-D2254
70 to 225 1 1 to 4 4 0.1 Directional 60 x 40 2.5 x 2.5 0.4 (Ni) yes 100 -25 to +70 -40 to +80 5.0 24 IP65 44

XS-D2504
70 to 250 1 1 to 4 4 0.1 Directional 60 x 40 2.5 x 2.5 0.4 (Ni) yes 100 -25 to +70 -40 to +80 5.0 24 IP65 51

* : Maximum continuous exposure time: 5 min.

Zoning Les Plenesses Rue du Progrs, 3 B-4821 Dison - Belgium


#1109 / 2.33 - All specications are non contractual and subject to change without prior notice.

Tel: +32 (0) 87 / 440 150 Fax: +32 (0) 87 / 440 160 E-mail: [email protected]

www.icmxray.com/ndt