Contents
General data
Performance range, DME Performance range, DMS Digital Dosing Type key 3 3 4 5
Functions
Overview of functions Functional description, DME Functional description, DMS Control panel Menu Operating modes Dosing monitoring Control panel lock Wiring diagram, DME and DMS-A (0-48 l/h) Wiring diagram, DME-A (60-940 l/h) 6 7 8 9 11 12 16 17 18 19
Construction
DME (0-48 l/h) DME (60-940 l/h) DMS (0-12 l/h) 21 22 23
Dimensions
DME and DMS (0-48 l/h) with front-fitted control panel DME and DMS (0-48 l/h) with side-fitted control panel DME (60 and 150 l/h) DME (375 and 940 l/h) 24 24 25 25
Technical data
DME (0-48 l/h) DME (60-940 l/h) DMS (0-12 l/h) 26 27 28
Pump selection
DME (0-48 l/h), standard range DME (0-48 l/h), non-standard range DME (60-940 l/h), standard range DME (60-940 l/h), non-standard range DMS (0-12 l/h), standard range DMS (0-12 l/h), non-standard range 29 30 31 33 34 36
Pumped liquids
List of pumped liquids 37
General data
Performance range, DME
p [bar]
18
DME
16 DME 2-18 14
12
10
8 DME 8-10 6 DME 12-6 4 DME 150-4 2 DME 48-3 0 1 2.5 7.5 12 18.5 48 60 150 250 376 940 DME 940-4
TM02 7811 4103 TM02 7810 4103
DME 375-10
Q [l/h]
DMS
Q [l/h]
General data
DME and DMS
Fewer variants to cover all needs The pumps feature powerful variable speed motor, a turn-down ratio of 1:1000/1:800 and a complete control interface including the following: full pulse control pulse batch control internal timer batch control analog 0/4-20 mA control
TM03 8020 0207
level control fieldbus communication module. This ensures that the DME pumps cover the range from 0 to 940 litres per hour up to 18 bar. The switch mode power supply ensures that the same pump is working precisely, irrespective of the mains supply (100-240 V; 50-60 Hz). The DMS version with synchronous motor and a turndown ratio of 1:100 (consisting of four pump sizes and three control versions) cover the range from 0 to 12 l/h. The DMS-A pumps have external pulse, analog 0/4-20 mA and level control interface; the DMS-AR is a DMS-A pump equipped with an alarm relay output. The DMS-B version is without external control interface. The DMS-D is without control and user interface. The DME and DMS dosing pumps feature diaphragm dosing head with integrated vent valve, suction and discharge ball valves. The pumps are fitted with power cable and plug.
Digital Dosing
Digital Dosing represents state-of-the-art technology. This patented Grundfos solution sets new standards, including new principles and methods. Precise and easy setting The operator can easily install and set the pump to discharge exactly the quantity of dosing liquid required in the application. In the display, the setting of the pump is read out directly in ml/h or l/h, pulse or batch, and the operation mode is easily identified by means of icons. Unique technology A unique drive and microprocessor control ensure that dosing liquids are discharged precisely and with low pulsation even when the pump is operating with high viscosity or degassing liquids. Instead of the conventional stroke length adjustment, the capacity of the DME is regulated by automatic adjustment of the motor speed during the discharge stroke and by fixed suction stroke speed, ensuring optimal and uniform mixing. The capacity of the DMS is regulated by automatic regulation of the stroke frequency.
General data
Type key
Example Type range Maximum capacity [l/h] Maximum pressure [bar] Control variant A AR AP AG B D DME 2 - 18 A - PP / E / C F 1 1 1 F Mains plug F B G I E J
Connection suction/discharge 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O Q V W Y A1 A2 A3 A4 C2 Tubing 6/9 4/6 mm Tubing 6/9 6/12 9/12 mm Tubing 4/6 mm Tubing 6/9 mm Tubing 6/12 mm Tubing 9/12 mm Hose clamp d. 6 mm Hose clamp d. 9 mm Hose clamp d. 16 mm Threaded Rp 1/4 Threaded Rp 3/8 Threaded Rp 1/2 Threaded Rp 1 Cementing d 10 mm Cementing d 12 mm Cementing d 16 mm Cementing d 20 mm Cementing d 25 mm Cementing d 32 mm Cementing d 40 mm Flange DN 15 Flange DN 25 Tubing 8/12 mm 1/2" 150 LBS Flange Tubing 19/27 mm + 25/34 mm Threaded 1/4" NPT Tubing 32/41 mm + 38/48 mm Threaded 3/8" NPT Threaded Rp 3/4 Threaded Rp 1 1/4 Threaded 3/4" NPT Threaded 1 1/4" NPT Piping 8/10 mm
Valve ball material C SS G T Y Ceramic Stainless steel, DIN 1.4401 Glass PTFE Hastelloy C-22
Supply voltage 1 2 3 6 8 9 1 1 1 1 1 1 x x x x x x 230 V, 50 Hz 120 V, 60 Hz 100-240 V, 50-60 Hz 110 V, 50 Hz 100 V, 50/60 Hz 200 V, 50/60 Hz
Functions
Overview of functions
DME
0-48 l/h 60-940 l/h AR 60-940 l/h B Variant A
DMS
Variant B Variant D
Capacity control, see page 7 Internal stroke-frequency control Internal stroke-speed control Control panel, see page 9 Capacity setting in litres, millilitres or US gallons Display with background light and soft-touch buttons Easy set-up menu with language options On/off button Maximum capacity button (priming) Green indicator light for operating indication Red indicator light for fault indication Control panel lock Side-fitted as an option Operating modes, see page 12 Manual control Pulse control Analog 0/4-20 mA control Timer-based batch control Pulse-based batch control Functions, see page 15 Dosing monitoring Dual-level control Calibration of pump to actual installation Anti-cavitation (reduced suction speed) Capacity limitation Counters for strokes, operating hours and power on/off Fieldbus communication Overload protection Error message in display Leakage sensor Dosing signal output Power supply, page 15 Switch-mode power supply Inputs/outputs, see page 18 Input for pulse control Input for analog 0/4-20 mA control Input for dual-level control Input for external start/stop Alarm relay output (variant AR) Dosing output Input for external on/off switch
Functions
Functional description, DME
The electronically controlled variable-speed motor of the DME pumps provides optimum control of the stroke speed. As shown in the figure below, the duration of each suction stroke is constant while the duration of each discharge stroke varies according to the capacity set, resulting in optimum discharge flow in any operating situation. The advantages are as follows: The pump always operates at full stroke length, irrespective of the capacity set; this ensures optimum accuracy, priming and suction. A capacity range of 1:1000 (0-48 l/h) for each pump size. A capacity range of 1:800 (60-940 l/h) for each pump size. Even and constant dosing ensuring an optimum mixing ratio at the injection point. Significant reduction of pressure surges, preventing mechanical stress on diaphragm, tubes, connections and other dosing parts exposed to leakage and wear. The installation is less affected by long suction and discharge lines. Easier dosing of highly viscous and gas-containing liquids. The optimum dosing control shown below takes place in any operating mode.
Capacity setting 100% Suction Discharge 50% Suction
Discharge Duration
Duration
10% Suction
Duration
Discharge
Functions
Functional description, DMS
The electronically-controlled, synchronous motor of the DMS pumps offers almost the same advantages as those of DME pumps. As shown in the figure below, the suction and discharge stroke speeds are constant while the stroke frequency varies according to the capacity set. The sinusoidal movement of the diaphragm offers the following advantages: The pump always operates at full stroke length, irrespective of the capacity set; this ensures optimum accuracy, priming and suction. A capacity range of 1:100 for each pump size. Reduction of pressure surges, preventing mechanical stress on diaphragm, tubes, connections and other dosing parts exposed to leakage and wear. The installation is less affected by long suction and discharge lines. Easier dosing of highly viscous and gas-containing liquids.
Capacity setting 100% Suction Discharge 50% Suction Discharge 10% Suction Discharge
Duration
Duration
Duration
Functions
Control panel
LCD display
ml/h
Menu/accept
Navigation/ settings
DME-AR and DMS-AR pumps can activate an external alarm signal by means of a built-in alarm relay. The alarm signal is activated by means of an internal potential-free contact.
TM01 8946 1202
The indicator lights and the alarm relay output indicate the operating state of the pump. See this overview:
Green Red indicator indicator light light Alarm relay output 1
Priming button
On/off button
Operating state
Display
Pump running
On
Off
Normal indication
1 2 3 NC NO C
Set to stop
Flashing
Off
Normal indication
1 2 3 NC NO C
Pump fault
Off
On
EEPROM
1 2 3 NC NO C
Supply failure
Off
Off
Off
1 2 3 NC NO C
On
On
Normal indication
1 2 3 NC NO C
Empty tank 2
TM01 8949 0900
Off
On
Normal indication
1 2 3 NC NO C
Off
On
Normal indication
1 2 3 NC NO C
Priming button
If the maximum capacity is required over a short period of time, for example during start-up, press the 100% button on the pump control panel. When the button is released, the pump automatically returns to the previous operating mode. To set the pump to run for a specific number of seconds at maximum capacity, press the 100% and buttons simultaneously. The remaining number of seconds appear in the display. This feature is useful when flushing the pump. The maximum value is 300 seconds. To stop the pump before the set time has passed, press the button.
Insufficient dosing according to the signal from the dosing monitor 3 More pulses than capacity
On
On
Normal indication
1 2 3 NC NO C
On
On
Normal indication
1 2 3 NC NO C
Overheated
Off
On
MAX TEMP
1 2 3 NC NO C