CatalogoDME-DMS Coagulant Pumps

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

GRUNDFOS ALLDOS DATA BOOKLET

DME and DMS


DIGITAL DOSING

Contents

General data
Performance range, DME Performance range, DMS Digital Dosing Type key 3 3 4 5

Functions
Overview of functions Functional description, DME Functional description, DMS Control panel Menu Operating modes Dosing monitoring Control panel lock Wiring diagram, DME and DMS-A (0-48 l/h) Wiring diagram, DME-A (60-940 l/h) 6 7 8 9 11 12 16 17 18 19

Construction
DME (0-48 l/h) DME (60-940 l/h) DMS (0-12 l/h) 21 22 23

Dimensions
DME and DMS (0-48 l/h) with front-fitted control panel DME and DMS (0-48 l/h) with side-fitted control panel DME (60 and 150 l/h) DME (375 and 940 l/h) 24 24 25 25

Technical data
DME (0-48 l/h) DME (60-940 l/h) DMS (0-12 l/h) 26 27 28

Pump selection
DME (0-48 l/h), standard range DME (0-48 l/h), non-standard range DME (60-940 l/h), standard range DME (60-940 l/h), non-standard range DMS (0-12 l/h), standard range DMS (0-12 l/h), non-standard range 29 30 31 33 34 36

Pumped liquids
List of pumped liquids 37

Further product documentation


WebCAPS WinCAPS 38 39

General data
Performance range, DME
p [bar]
18

DME and DMS

DME

16 DME 2-18 14

12

10

8 DME 8-10 6 DME 12-6 4 DME 150-4 2 DME 48-3 0 1 2.5 7.5 12 18.5 48 60 150 250 376 940 DME 940-4
TM02 7811 4103 TM02 7810 4103

DME 60-10 DME 19-6

DME 375-10

Q [l/h]

Fig. 1 Performance range, DME


Note: The maximum capacity is available at the pumps maximum counter-pressure if the pump has been calibrated to the actual installation.

Performance range, DMS


p [bar]
11 10 9 8 7 6 5 DMS 2-11 4 DMS 4-7 3 DMS 8-5 2 DMS 12-3 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13

DMS

Q [l/h]

Fig. 2 Performance range, DMS


Note: The maximum capacity is available at the pumps maximum counter-pressure if the pump has been calibrated to the actual installation.

General data
DME and DMS

DME and DMS

Fewer variants to cover all needs The pumps feature powerful variable speed motor, a turn-down ratio of 1:1000/1:800 and a complete control interface including the following: full pulse control pulse batch control internal timer batch control analog 0/4-20 mA control
TM03 8020 0207

level control fieldbus communication module. This ensures that the DME pumps cover the range from 0 to 940 litres per hour up to 18 bar. The switch mode power supply ensures that the same pump is working precisely, irrespective of the mains supply (100-240 V; 50-60 Hz). The DMS version with synchronous motor and a turndown ratio of 1:100 (consisting of four pump sizes and three control versions) cover the range from 0 to 12 l/h. The DMS-A pumps have external pulse, analog 0/4-20 mA and level control interface; the DMS-AR is a DMS-A pump equipped with an alarm relay output. The DMS-B version is without external control interface. The DMS-D is without control and user interface. The DME and DMS dosing pumps feature diaphragm dosing head with integrated vent valve, suction and discharge ball valves. The pumps are fitted with power cable and plug.

Fig. 3 DME and DMS

Digital Dosing
Digital Dosing represents state-of-the-art technology. This patented Grundfos solution sets new standards, including new principles and methods. Precise and easy setting The operator can easily install and set the pump to discharge exactly the quantity of dosing liquid required in the application. In the display, the setting of the pump is read out directly in ml/h or l/h, pulse or batch, and the operation mode is easily identified by means of icons. Unique technology A unique drive and microprocessor control ensure that dosing liquids are discharged precisely and with low pulsation even when the pump is operating with high viscosity or degassing liquids. Instead of the conventional stroke length adjustment, the capacity of the DME is regulated by automatic adjustment of the motor speed during the discharge stroke and by fixed suction stroke speed, ensuring optimal and uniform mixing. The capacity of the DMS is regulated by automatic regulation of the stroke frequency.

General data
Type key
Example Type range Maximum capacity [l/h] Maximum pressure [bar] Control variant A AR AP AG B D DME 2 - 18 A - PP / E / C F 1 1 1 F Mains plug F B G I E J

DME and DMS

EU (Schuko) USA, Canada (120 V) UK Australia Switzerland Japan

A + alarm relay A + PROFIBUS A + GENIbus Basic Only on/off

Connection suction/discharge 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O Q V W Y A1 A2 A3 A4 C2 Tubing 6/9 4/6 mm Tubing 6/9 6/12 9/12 mm Tubing 4/6 mm Tubing 6/9 mm Tubing 6/12 mm Tubing 9/12 mm Hose clamp d. 6 mm Hose clamp d. 9 mm Hose clamp d. 16 mm Threaded Rp 1/4 Threaded Rp 3/8 Threaded Rp 1/2 Threaded Rp 1 Cementing d 10 mm Cementing d 12 mm Cementing d 16 mm Cementing d 20 mm Cementing d 25 mm Cementing d 32 mm Cementing d 40 mm Flange DN 15 Flange DN 25 Tubing 8/12 mm 1/2" 150 LBS Flange Tubing 19/27 mm + 25/34 mm Threaded 1/4" NPT Tubing 32/41 mm + 38/48 mm Threaded 3/8" NPT Threaded Rp 3/4 Threaded Rp 1 1/4 Threaded 3/4" NPT Threaded 1 1/4" NPT Piping 8/10 mm

Dosing head material PP PV SS Polypropylene PVDF Stainless steel

Gasket material E T V EPDM PTFE FKM

Valve ball material C SS G T Y Ceramic Stainless steel, DIN 1.4401 Glass PTFE Hastelloy C-22

Control panel position F S X Front-fitted Side-fitted No control panel

Supply voltage 1 2 3 6 8 9 1 1 1 1 1 1 x x x x x x 230 V, 50 Hz 120 V, 60 Hz 100-240 V, 50-60 Hz 110 V, 50 Hz 100 V, 50/60 Hz 200 V, 50/60 Hz

Valves 1 2 Standard valve Spring-loaded valve

Functions
Overview of functions
DME
0-48 l/h 60-940 l/h AR 60-940 l/h B Variant A

DME and DMS

DMS
Variant B Variant D

TM01 8941 0900

TM02 8337 4903

TM02 8338 4903

TM01 8941 0900

TM01 8943 0900

Capacity control, see page 7 Internal stroke-frequency control Internal stroke-speed control Control panel, see page 9 Capacity setting in litres, millilitres or US gallons Display with background light and soft-touch buttons Easy set-up menu with language options On/off button Maximum capacity button (priming) Green indicator light for operating indication Red indicator light for fault indication Control panel lock Side-fitted as an option Operating modes, see page 12 Manual control Pulse control Analog 0/4-20 mA control Timer-based batch control Pulse-based batch control Functions, see page 15 Dosing monitoring Dual-level control Calibration of pump to actual installation Anti-cavitation (reduced suction speed) Capacity limitation Counters for strokes, operating hours and power on/off Fieldbus communication Overload protection Error message in display Leakage sensor Dosing signal output Power supply, page 15 Switch-mode power supply Inputs/outputs, see page 18 Input for pulse control Input for analog 0/4-20 mA control Input for dual-level control Input for external start/stop Alarm relay output (variant AR) Dosing output Input for external on/off switch

TM02 8973 1304

Functions
Functional description, DME
The electronically controlled variable-speed motor of the DME pumps provides optimum control of the stroke speed. As shown in the figure below, the duration of each suction stroke is constant while the duration of each discharge stroke varies according to the capacity set, resulting in optimum discharge flow in any operating situation. The advantages are as follows: The pump always operates at full stroke length, irrespective of the capacity set; this ensures optimum accuracy, priming and suction. A capacity range of 1:1000 (0-48 l/h) for each pump size. A capacity range of 1:800 (60-940 l/h) for each pump size. Even and constant dosing ensuring an optimum mixing ratio at the injection point. Significant reduction of pressure surges, preventing mechanical stress on diaphragm, tubes, connections and other dosing parts exposed to leakage and wear. The installation is less affected by long suction and discharge lines. Easier dosing of highly viscous and gas-containing liquids. The optimum dosing control shown below takes place in any operating mode.
Capacity setting 100% Suction Discharge 50% Suction

DME and DMS

Discharge Duration

Duration

10% Suction

Duration

Fig. 4 Relation between stroke-frequency adjustment and capacity for DME

TM01 8944 0900

Discharge

Functions
Functional description, DMS
The electronically-controlled, synchronous motor of the DMS pumps offers almost the same advantages as those of DME pumps. As shown in the figure below, the suction and discharge stroke speeds are constant while the stroke frequency varies according to the capacity set. The sinusoidal movement of the diaphragm offers the following advantages: The pump always operates at full stroke length, irrespective of the capacity set; this ensures optimum accuracy, priming and suction. A capacity range of 1:100 for each pump size. Reduction of pressure surges, preventing mechanical stress on diaphragm, tubes, connections and other dosing parts exposed to leakage and wear. The installation is less affected by long suction and discharge lines. Easier dosing of highly viscous and gas-containing liquids.
Capacity setting 100% Suction Discharge 50% Suction Discharge 10% Suction Discharge

DME and DMS

Duration

Duration

Duration

Fig. 5 Relation between stroke-frequency adjustment and capacity for DMS

TM01 8945 0900

Functions
Control panel
LCD display
ml/h

DME and DMS

Indicator lights and alarm relay output (0-48 l/h)


The green and red indicator lights on the control panel indicate operation or fault.
Navigation/ settings

Menu/accept

Navigation/ settings

Green indicator light Red indicator light


100%

DME-AR and DMS-AR pumps can activate an external alarm signal by means of a built-in alarm relay. The alarm signal is activated by means of an internal potential-free contact.
TM01 8946 1202

The indicator lights and the alarm relay output indicate the operating state of the pump. See this overview:
Green Red indicator indicator light light Alarm relay output 1

Priming button

On/off button

Operating state

Display

Fig. 6 Control panel

Pump running

On

Off

Normal indication

1 2 3 NC NO C

Set to stop

Flashing

Off

Normal indication

1 2 3 NC NO C

TM01 8941 0900

Pump fault

Off

On

EEPROM
1 2 3 NC NO C

Fig. 7 Front-fitted control panel

Supply failure

Off

Off

Off
1 2 3 NC NO C

Pump running, low chemical level2

On

On

Normal indication

1 2 3 NC NO C

Empty tank2
TM01 8949 0900

Off

On

Normal indication

1 2 3 NC NO C

Analog signal < 2 mA

Off

On

Normal indication

1 2 3 NC NO C

Fig. 8 Side-fitted control panel (not including DMS-B)

Priming button
If the maximum capacity is required over a short period of time, for example during start-up, press the 100% button on the pump control panel. When the button is released, the pump automatically returns to the previous operating mode. To set the pump to run for a specific number of seconds at maximum capacity, press the 100% and buttons simultaneously. The remaining number of seconds appear in the display. This feature is useful when flushing the pump. The maximum value is 300 seconds. To stop the pump before the set time has passed, press the button.

Insufficient dosing according to the signal from the dosing monitor 3 More pulses than capacity

On

On

Normal indication

1 2 3 NC NO C

On

On

Normal indication

1 2 3 NC NO C

Overheated

Off

On

MAX TEMP

1 2 3 NC NO C

1 2 3

Applies only to control variant AR. Requires connection to level sensors. Requires activation of the dosing monitoring function and connection to a dosing monitor.

Functions
Indicator lights and alarm relay output (60-940 l/h)
Operating state Green Red indicator indicator Display light light Normal indication Alarm relay output1

DME and DMS

Pump running

On

Off

1 2 3 NC NO C

Set to stop

Flashing

Off

Normal indication

1 2 3 NC NO C

Pump fault

Off

On

EEPROM

1 2 3 NC NO C

Supply failure

Off

Off

Off
1 2 3 NC NO C

Pump running, low chemical level 2

On

On

LOW
1 2 3 NC NO C

Empty tank 2

Off

On

EMPTY
1 2 3 NC NO C

Analog signal < 2 mA

Off

On

NO mA
1 2 3 NC NO C

Insufficient dosing according to signal from dosing monitor 3

On

On

NO FLOW

1 2 3 NC NO C

Overheating

Off

On

MAX TEMP

1 2 3 NC NO C

Internal communication failure

Off

On

INT COM
1 2 3 NC NO C

Internal Hall failure 4

Off

On

HALL
1 2 3 NC NO C

Diaphragm failure (leakage) 5

Off

On

LEAKAGE

1 2 3 NC NO C

Max. pressure exceeded 5

Off6

On

OVERLOAD

1 2 3 NC NO C

More pulses than capacity

On

On

MAX FLOW

1 2 3 NC NO C

No detection of motor rotation 4 1 2 3 4 5 6

On

On

ORIGO
1 2 3 NC NO C

Applies only to control variant AR. Requires connection to level sensors. Requires activation of the dosing monitoring function and connection to a dosing monitor. Please contact a Grundfos service centre. After the fault has been rectified, press to reset alarms.

The pump makes 10 attempts to restart before going into permanent off mode.

10

Functions
Menu
The DME and DMS dosing pumps feature a userfriendly menu. To activate the menu, press the button. During initial start-up, all menu texts appear in the English language. You can set the menu to display other languages, see page 15. This example applies to DME pumps:

DME and DMS

mA


Fig. 9 Menu overview
D68se

Applies only to DME, 60-940 l/h pumps.

11

Functions
Operating modes
Manual control
The pump ensures constant dosing according to the quantity set in l/h or ml/h by means of the and buttons. The pump automatically changes between the measuring units. Setting range, DME
Setting range DME pump DME 2 DME 8 DME 12 DME 19 DME 48 DME 60 DME 150 DME 375 DME 940 From [ml/h] 2.5 7.5 12 18.5 48 75 200 500 1200 To [l/h] 2.5 7.5 12 18.5 48 60 150 376 940 0-20: 20-0: 20-4: Setting 4-20 (default) Input signal 4 mA 20 mA 4 mA 20 mA 0 mA 20 mA 0 mA 20 mA

DME and DMS

Setting range, DMS


DMS pump DMS 2 DMS 4 DMS 8 DMS 12 Setting range [ml/pulse] 0.00232 - 50 0.00370 - 80 0.00695 - 150 0.01110 - 240

Analog 0/4-20 mA control


Applies to DME-A and DMS-A The pump ensures dosing according to an external analog signal. The dosed capacity is proportional to the input value in mA.
Dosed quantity as a percentage of the max. capacity* 0% 100% 100% 0% 0% 100% 100% 0%

When the anti cavitation functions is enabled the maximum flow is reduced. See page 26-27.

Setting range, DMS


Setting range DMS pump DMS 2 DMS 4 DMS 6 DMS 12 From [ml/h] 25 40 75 120 To [l/h] 2.5 Maximum capacity [%] 4 7.5 12

* If a maximum capacity limitation has been set, the dosed quantity is a percentage of the set capacity limitation, see page 14.

100 80 60 40 20 0 0 4 8 12 Input signal [mA] 16 20


4-20 mA signal 4-20 mA signal
TM01 8218 0100

Pulse control
Applies to DME-A and DMS-A The pump doses according to an external pulse signal, for example from a water meter. There is no direct relation between pulses and dosing strokes. The pump automatically calculates its optimal speed to ensure the required quantity is dosed for each pulse. The quantity to be dosed is set in ml/pulse. The pump adjusts its speed and/or stroke frequency according to two factors: frequency of external pulses the set quantity per pulse. Setting range, DME
DME pump DME 2-18 DME 8-10 DME 12-6 DME 19-6 DME 48-3 DME 60-10 DME 150-4 DME 375-10 DME 940-4 Setting range [ml/pulse] 0.000023 - 5.0 0.000069 - 15.0 0.000111 - 24.0 0.000204 - 37.0 0.000530 - 96.0 0.000625 - 120 0.00156 - 300 0.00392 - 750 0.00980 - 1880

Fig. 10 4-20 mA control

12

Functions
Timer-based batch control
Applies to DME-A The set quantity is dosed in batches at maximum capacity or the set capacity limitation. The time until the first dosing (NX) and the following sequences (IN) can be set in minutes, hours and days. The maximum time limit is 9 days, 23 hours and 59 minutes (9:23:59). The lowest acceptable value is one minute. IN must be higher than the time required to perform one batch. If IN is lower than the time required, the next batch will be ignored. In case of supply failure, the set dosing quantity, the IN time and the remaining NX time are stored. When the supply is reconnected, the pump starts up with the NX time at the time of the supply failure. Thus, the timer cycle continues, but it will be delayed according to the time of the supply failure.
Pulse Quantity per batch Pulse

DME and DMS

Pulse-based batch control


Applies to DME-A The set quantity is dosed in batches at maximum capacity or the set capacity limitation. The quantity is dosed every time the pump receives an external pulse. If the pump receives new pulses before the batch is completed, these pulses will be ignored.
Quantity per batch

t
TM01 8947 0900

Fig. 12 Pulse-based batch control

Setting range, DME


Setting range DME pump
TM01 8942 0900

From [ml/batch] 0.23 0.69 1.11 2.04 5.3 6.25 15.6 39.1 97.9

To [l/batch] 5 15 24 37 96 120 300 750 1880.

DME 2 DME 8 DME 12 DME 19 DME 48 DME 60 DME 150 DME 375 DME 940

NX IN

Fig. 11 Timer-based batch control

Setting range, DME


Setting range DME pump DME 2 DME 8 DME 12 DME 19 DME 48 DME 60 DME 150 DME 375 DME 940 From [ml/batch] 0.23 0.69 1.11 2.04 5.3 6.25 15.6 39.1 97.9 To [l/batch] 5 15 24 37 96 120 300 750 1880

13

Functions
Anti-cavitation
When the anti-cavitation function is selected, the pump extends and smooths its suction stroke. This results in a softer suction stroke. The anti-cavitation function is used in these situations: when pumping high-viscosity liquids when pumping degassing liquids when the suction tube is long when the suction lift is high. DME (0-48 l/h) The maximum capacity is reduced when the anti-cavitation function is selected, See page 26 for details. DME (60-940 l/h) Depending on the circumstances, the motor speed during the suction stroke can be reduced to approximately 75%, 50% or 25% of the normal motor speed. When using the anti-cavitation function, the maximum pump capacity is reduced. See page 27 for details.
Fig. 13 Anti-cavitation

DME and DMS

3. To cover several needs with just one pump size. 4. To adapt the pump to a 4-20 mA signal control with 4 mA corresponding to 0% and 20 mA to the set maximum capacity. This allows you to use for example a DME 48 for dosing a very small quantity of liquid without having to change the input signal. See the example below. Example A DME 48 receives a 12 mA input signal from a control instrument. This results in a 50% output (according to the analog curve on page 12) and a capacity of 24 l/h. A new situation occurs where it is only necessary to dose 2 l/h. The maximum capacity limitation is set to 4 l/h. The pump is still receiving a 12 mA signal resulting in a 50% output and a capacity of 2 l/h.
Q [l/h] 48 44 40 36 32 28 24 20 16 12 8 4 0 0 2 4 6

The maximum capacity limitation function allows a large pump to be set to operate as a much smaller pump. Together with the 1:1000/1:800 capacity range, this function allows the following: 1. To utilize the smooth and even dosing characteristics of the pump at low capacities to achieve improved chemical mixing improved dosing through long discharge tubes improved dosing of high-viscosity liquids. 2. To improve the dosing of gas-containing liquids: In a large pump, as compared to a small pump, the displaced volume (1) is much larger than the non-displaced volume (2). See fig. 13.

8 10 12 14 16 18 20 [mA]

Fig. 14 Maximum capacity limitation

The maximum capacity limitation also reduces the pump speed in timer-based batch control, pulse-based batch control and during calibration where the pump usually operates at maximum capacity.

2
TM02 0158 3301

Small pump

Large pump

14

TM01 9638 2700

Maximum capacity limitation makes it possible to reduce the maximum capacity (MAX. CAP). It influences the functions in which the pump normally operates at maximum capacity. Under normal operating conditions, the pump cannot operate at a capacity higher than the one stated in the display. This does not apply to the priming button.

No

ca

p.

li m

Applies to DME

i ta Ca p. lim it = 4 l /h

ti o

Maximum capacity limitation

Functions
Calibration
After start-up, the dosing pumps can be calibrated for the actual installation to ensure that the displayed value (millilitres or litres) is correct. A calibration program in the set-up menu facilitates calibration.

DME and DMS

On DME 60-940 l/h the vent valve must be connected to the tank by means of a 15/20 mm PVC tubing. See fig. 16.

Counters
The pump can display non-resettable counters for: "Quantity" Accumulated dosed quantity in litres or US gallons. "Strokes" Accumulated number of dosing strokes. "Hours" Accumulated number of operating hours (power on). "Power ON" Accumulated number of times the mains supply has been switched on.
Fig. 16 Integrated vent valve, DME 60-940 l/h
Vent valve
TM02 7066 2503

Switch-mode power supply


The DME pump incorporates a switch-mode power supply. This makes the pump independent of variations in supply voltage and frequency. Operating range: 1 x 100-240 V, 50-60 Hz.

Languages
The display text can be displayed in one of the following languages chosen in the set-up menu: English German French Italian Spanish Portuguese Dutch Swedish Finnish Danish Czech Slovak Polish Russian.

Level control
Applies to DME-A and DMS-A The pump can be connected to a level control unit for monitoring of the chemical level in the tank. The pump can react to two level signals. The following table shows the pump reactions to the sensor signals:
Level sensors Upper sensor activated Pump reaction Red indicator light is on. Pump is running. Alarm relay is activated. Red indicator light is on. Pump stops . Alarm relay is activated.

Lower sensor activated

Applies to control variant AR

Bus communication
Applies to DME The pump is available with a built-in module for bus communication with GENIbus (variant AG, up to 48 l/h only) or PROFIBUS DP (variant AP) systems. These modules enable remote monitoring and setting via the fieldbus system. All DME features are available via bus communication. The PROFIBUS GDS-file can be downloaded from www.grundfosalldos.com.

Integrated vent valve


The DME and DMS dosing pumps are provided with an integrated vent valve. The valve makes it very easy to prime the pump during start-up: On DME and DMS, 0-48 l/h the vent valve must be connected to the tank by means of a 4/6 mm PVC tubing. See fig. 15.

Diaphragm leakage sensor (60-940 l/h)


TM03 7845 4906

Vent valve

The pump can be fitted with a diaphragm leakage sensor. The sensor detects leakage from the diaphragm. The sensor should be connected to the drain hole of the pump head. In case of leakage of the diaphragm, the signal from the sensor generates an alarm in the pump and the alarm relay is activated.

Fig. 15 Integrated vent valve, DME and DMS 0-48 l/h

15

Functions
Dosing monitoring
General description Logic

DME and DMS

If a number of incorrect dosing strokes are performed, the pump will continue operating, but it will change over to alarm mode. The red indicator light will be on and the alarm output, if any, will be activated (variant AR). When a correct dosing stroke is detected, the red indicator light is turned off and the alarm output, if any, is deactivated.

Fig. 17 Dosing monitor mounted on pump discharge side

The dosing monitor is designed to monitor the dosing of liquids which may cause gas accumulation in the dosing head, thus stopping the dosing process even if the pump is still operating. During the dosing process, the dosing monitor gives pulse signals to the monitor input so that the pump can compare performed dosing strokes (from internal stroke sensor) with externally measured physical strokes (from the dosing monitor). If an external dosing stroke is not measured as a result of the internal dosing stroke, this is considered a fault that may have been provoked by empty tank or gas in the dosing head. DME/DMS 2 to 48: The dosing monitor should be connected to the "low level" input (pins 2 and 3). This input must be configured for dosing monitoring. Consequently, it cannot be used as a level input. DME 60 to 150: The dosing monitor should be connected to the input for dosing monitoring (pins 4 and 5). This input must be configured for dosing monitoring. Once the input has been set to dosing monitoring and a dosing monitor has been connected and set, the dosing monitoring function will be active.

Definitions
Correct dosing stroke: A pulse from the dosing monitor corresponds to the internal stroke signal within acceptable time. Incorrect dosing stroke: There is no pulse from the dosing monitor corresponding to the internal stroke signal within the acceptable time (the pump is not pumping).

16

GRA1031

Functions
Control panel lock
It is possible to lock the buttons on the control panel to prevent maloperation of the pump. The locking function can be set to ON or OFF. The default setting is OFF. A pin code is required to change from OFF to ON. When ON is selected for the first time, the indication "_ _ _ _" appears in the display. If a code has already been entered, the code will appear when an attempt to change to ON is made. This code can either be reentered or changed.

DME and DMS

US measuring units
In manual and analog modes, set the quantity to be dosed in gallons per hour (gph). In pulse mode, set the quantity to be dosed in ml/ pulse. The actual capacity is shown in gallons per hour (gph). For calibration, set the quantity to be dosed in ml per 100 strokes. In timer and batch modes, set the quantity to be dosed in gallons. Under the QUANTITY menu item in the COUNTERS menu, the dosed quantity is indicated in gallons (gal).

Units
It is possible to select metric units (litre/millilitre) and US units (gallons/millilitre).

Metric measuring units


In manual and analog modes, set the quantity to be dosed in litres per hour (l/h) or millilitres per hour (ml/h). In pulse mode, set the quantity to be dosed in ml/ pulse. The actual capacity is indicated in litres per hour (l/h) or millilitres per hour (ml/h). For calibration, set the quantity to be dosed in ml per 100 strokes. In timer and batch modes, set the quantity to be dosed in litres (l) or millilitres (ml). Under the QUANTITY menu item in the COUNTERS menu, the dosed quantity is indicated in litres.

3x

Operating display

Operating display

Fig. 18 Possible units settings

17

Functions
Wiring diagram, DME and DMS-A (0-48 l/h)
See pages 26 and 28 for input/output data.
"NO" black "NC" blue "COM" brown

DME and DMS

Control cable Product No.: 2 m cable: 96440447 5 m cable: 96440448

Level cable Product No.: 2 m cable: 96440450 5 m cable: 96440451

2 5 3/4 3/4 1 1 4
The level switch contacts (normally open) must be closed at low level/empty tank.

3
TM03 7853 5006

Empty tank Low level

Control input
Pin holes Number/colour Function Pulse Pulse Analog Batch Batch External start/stop Only pulse/batch mode Only pulse/batch mode All other modes All other modes X 5V X GND X GND X 5V Contact Supply 5 VDC Contact Supply 5 VDC X 5V X GND X 5V X GND () mA input (+) mA input Contact Supply 5 VDC mA signal Contact Supply 5 VDC 1/brown 2/white 3/blue, +5V 4/black, GND 5/grey Plug type

Level input
Pin holes Number/colour Function Low level Low level Empty tank Empty tank Dosing monitoring Dosing monitoring 5V 5V X X GND X 5V X X GND X GND (+) mA input Contact Supply 5 VDC Contact Supply 5 VDC Contact Supply 5 VDC 1/brown 2/white 3/blue, +5V 4/black, GND 5/grey Plug type

18

Functions
Wiring diagram, DME-A (60-940 l/h)

DME and DMS

2 3 5 1 4

2 3 5 1 4

2 3 4 1

2 3 1

3 1

4 3 1

2 1

4 3 1

Cable 1: Analog, pulse and leakage input


Pin holes Number/colour Function Pulse Pulse Analog Batch Batch Leakage Leakage X 5V X 5V X GND X GND X 5V X GND () mA input (+) mA input Contact Supply 5 VDC mA signal Contact Supply 5 VDC Contact Supply 5 VDC 1/brown 2/white 3/blue, +5V 4/black, GND 5/grey
Plug type

Cable 2: Output for alarm relay


Pin holes Number/colour Function Alarm relay output Common Normally open Normally closed 1/brown 2/white 3/blue

TM02 7069 2503

Cable 1 Analog/pulse/leakage cable Product No. 2 m cable: 96440447 5 m cable: 96440448

Cable 2 Relay cable Product No. 2 m cable: 96534214 5 m cable: 96534215

Cable 3 Stop dosing cable Product No. 2 m cable: 96527109 5 m cable: 96527111

Cable 4 Level cable Product No. 2 m cable: 96440450 5 m cable: 96440451

19

Functions
Cable 3: Stop dosing input and dosing monitor or dosing output
Pin holes Number/colour Function Stop input Stop input Dosing monitoring Dosing monitoring Dosing output (pump running) Open collector can be used for a relay or a lamp. 1. Using the internal 5V DC power supply: Max. current: 100 mA 2. Using an external power supply: Max. 24 VDC - 100 mA Open collector X X 5V X GND GND X GND X 5V 1/brown 2/white 3/blue, +5V 4/black, GND 5/grey

DME and DMS

Plug type

Contact Supply 5 VDC Contact Supply 5 VDC NPN

Relay

Lamp Lamp
TM03 7868 5006 TM03 7869 5006

24 VDC

Power supply

Cable 4: Level input


Pin holes Number/colour Function Low level Low level Empty tank Empty tank X 5V X 5V X GND X GND Contact Supply 5 VDC Contact Supply 5 VDC 1/brown 2/white 3/blue, +5V 4/black, GND 5/grey Plug type

The function for the potential free contact set can be chosen from the display (NO = Normally Open and NC = Normally Closed).

20

Construction
DME (0-48 l/h)

DME and DMS

Fig. 19 Sectional drawing, DME (0-48 l/h)

Construction
The DME pump is a motor-driven diaphragm dosing pump consisting of the following main parts: Dosing head: Designed with a minimum of clearance space to optimise the priming and deaerating capabilities. The dosing head has built-in valve housings. Valves: Double-ball suction valve and single-ball discharge valve. Spring-loaded valves are available as an option. Vent valve: For priming and deaeration complete with connection for a 4/6 mm tubing. Connections: Sturdy and easy-to-use connections for various sizes of tubing, pipe thread or pipe cementing. Diaphragm: PTFE-coated, textile-reinforced EPDM diaphragm designed for long life. Back plate: With separation chamber, safety diaphragm and drain hole. Drive unit: With diaphragm connecting rod, crank, beltdrive and stepper motor, all mounted on a sturdy frame. Cabinet: Containing drive unit, electronics, control panel and various electrical connections.

Material specification
Pos. Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Back plate Diaphragm Valve complete O-ring Valve casing Valve ball Valve seat disk Valve seat ring Cone/thread piece/ cementing piece Clamping ring Union nut Vent valve Vent valve ball Vent valve O-ring Cabinet Power/alarm cable Dosing head Drive belt Connecting rod Origo sensor Crank shaft Power PCB Operation PCB Stepper motor Drive frame Material options PPE/PS 20% glass fibre Textile-reinforced EPDM, PTFE-coated EPDM/FKM/PTFE PP/PVDF/Stainless steel 1.4401 Ceramic/Stainless steel 1.4401 EPDM/FKM/PTFE PP/PVDF/Stainless steel 1.4401

Connection complete PP/PVDF/Stainless steel 1.4401/PVC PP/PVDF PP/PVDF/Stainless steel 1.4401 PP/PVDF Ceramic/PTFE EPDM/FKM PPE/PS 20% glass fibre Rubber PP/PVDF/Stainless steel 1.4401 Rubber, polyamide-reinforced Steel Steel Aluminium

The pump can be supplied with spring-loaded valves. Spring material: Hastelloy.

TM03 7854 5006

21

Construction
DME (60-940 l/h)
29 20 21 5 19 18 17 16 15 6 28 27 26 25 24 23 1 2 3 4 38

DME and DMS

22

14 39 11 12 10

9 32 36 37 33

8 34 35

31 30
TM02 8599 5006

Fig. 20 Sectional drawing, DME (60-940 l/h)

Material specification
Pos. Description 1 2 3 4 5 6 7 8 9 Back plate Spring Cabinet Origo sensor Operation PCB (printed circuit board) Power cable Gear BLDC motor Drain hole or leakage sensor DME 60 and DME 150 19/25 mm hose nozzle 10 DME 375 and DME 940 connection with internal thread 1 1/4" NPT / Rp 1 1/4 Union nut Connection complete O-ring Venting valve ball Spring Spring Venting valve house Venting valve tap O-ring End cover Venting valve complete O-ring Valve seat Material options PPE/PS 20% glass fibre DIN 17223 TYPE C PPE/PS 20% glass fibre Rubber PP/PVDF PP/PVDF PP/PVDF EPDM/FKM Ceramic Hastelloy C Hastelloy C PP/PVDF PP/PVDF EPDM/FKM Steel EPDM/FKM PP/PVDF/SS 1.4401/PTFE 39 Diaphragm Pos. Description 25 26 28 29 30 31 32 33 34 35 36 37 38 Valve ball Valve casing O-ring Valve complete Steel plate Dosing head Safety membrane Power PCB (printed circuit board) Crank shaft I/O PCB (printed circuit board) Connecting rod Steel plate Steel frame Material options Ceramic/Glass/SS 1.4401/ Hastelloy C/PTFE PP/PVDF/SS 1.4401 Hastelloy C EPDM/FKM/PTFE Steel PP/PVDF/SS 1.4401 Steel Steel Steel Steel Textile-reinforced EPDM, PTFE-coated

27 Spring

11 12 14 15 16 17 18 19 20 21 22 23 24

The pump is available with spring-loaded valves. Spring material: Hastelloy.

22

Construction
DMS (0-12 l/h)

DME and DMS

Fig. 21 Sectional drawing, DMS

Construction
The DMS pump is a motor-driven diaphragm dosing pump consisting of the following main parts: Dosing head: Designed with a minimum of clearance space to optimise the priming and deaerating capability. The dosing head has built-in valve housings. Valves: Double-ball suction valve and single-ball discharge valve. Spring-loaded valves are available as an option. Vent valve: For priming and deaeration complete with connection for a 4/6 mm tubing. Connections: Sturdy and easy-to-use connections for various sizes of tubing, pipe thread or pipe cementing. Diaphragm: PTFE-coated, textile-reinforced EPDM diaphragm designed for long life. Back plate: With separation chamber, safety diaphragm and drain hole. Drive unit: With diaphragm connecting rod, crank, beltdrive and synchronous motor, all mounted on a sturdy frame. Cabinet: Containing drive unit, electronics, control panel and various electrical connections (DMS-A).

Material specification
Description Material options Back plate PPE/PS 20% glass fibre Diaphragm Textile-reinforced EPDM, PTFE-coated Valve complete O-ring EPDM/FKM/PTFE Valve casing PP/PVDF/Stainless steel Valve ball Ceramic/Stainless steel 1.4401 Valve seat disk EPDM/FKM/PTFE Valve seat O-ring PP/PVDF/Stainless steel 1.4401 Connection complete Cone/thread piece/ PP/PVDF/Stainless steel 1.4401/PVC 10 cementing piece 11 Clamping ring PP/PVDF 12 Union nut PP/PVDF/Stainless steel 1.4401 13 Vent valve PP/PVDF 14 Vent valve ball Ceramic/PTFE 15 Vent valve O-ring EPDM/FKM 16 Cabinet PPE/PS 20% glass fibre 17 Power/alarm cable Rubber 18 Dosing head PP/PVDF/Stainless steel 1.4401 19 Drive belt Rubber, polyamide-reinforced 20 Connecting rod Steel Dosing stroke 21 auxiliary spring 22 Crank shaft Steel 23 Power PCB 24 Operation PCB 25 Synchronous motor 26 Drive frame Aluminium The pump is available with spring-loaded valves. Spring material: Hastelloy. Pos. 1 2 3 4 5 6 7 8 9

TM03 7855 5006

23

Dimensions
DME and DMS (0-48 l/h) with front-fitted control panel

DME and DMS

Fig. 22 DME and DMS (0-48 l/h) with front-fitted control panel

DME and DMS (0-48 l/h) with side-fitted control panel

Fig. 23 DME and DMS (0-48 l/h) with side-fitted control panel
Dimensions [mm] Pump type A B C D DME 2 DMS 2 DMS 4 DME 8 DMS 8 137 245 36 168 DME 12 DMS 12 DME 19 192 300 15 188 DME 48

24

TM03 7851 4906

TM03 7850 4906

Dimensions
DME (60 and 150 l/h)

DME and DMS

Fig. 24 DME (60 and 150 l/h)

DME (375 and 940 l/h)

Fig. 25 DME (375 and 940 l/h)


Dimensions [mm] Pump type A B C D E F G H I DME 60 198 176 331 284 180 444 41 74 187 DME 150 198 176 345 284 180 444 28 74 187 DME 375 238 218 410 364 230 543 95 95 246 DME 940 238 218 430 364 230 543 75 95 246

DME 375 and 940 are equipped with 1 1/4" thread connections

TM03 7884 5006

TM02 7062 5106

25

Technical data
DME (0-48 l/h)
Pump Maximum capacity without anti-cavitation 1 Maximum capacity with anti-cavitation 1 Maximum pressure Maximum stroke frequency 2 [stroke/min] Mechanical data Maximum suction lift during operation [m] Maximum suction lift when priming with wet valves [m] Maximum viscosity with spring-loaded valves 3 [mPas] (= cP) Maximum viscosity without spring-loaded valves 3 [mPas] (= cP) Maximum liquid temperature [C] Minimum liquid temperature [C] Maximum ambient temperature [C] Minimum ambient temperature [C] Accuracy of repeatability Weight and size Weight [kg] Diaphragm diameter [mm] Supply voltage [V] Maximum current consumption [A] Electrical data Maximum power consumption P1 [W] Enclosure class Insulation class Voltage in level sensor input [VDC] Voltage in pulse input [VDC] Signal input Minimum pulse-repetition period [ms] Impedance in analog 0/4-20 mA input [] Maximum loop resistance in pulse signal circuit [] Maximum loop resistance in level signal circuit [] Signal output Sound pressure level Approvals 1 At any counter-pressure if the pump is calibrated to the actual installation. 2 The maximum stroke frequency varies according to calibration. 3 Maximum suction lift: 1 metre. Maximum load of alarm relay output, at ohmic load [A] Maximum voltage, alarm relay output [V] The sound pressure level of the pump is lower than [db(A)] at 100 V at 230 V 2.3 28 2.3 38 0.27 0.16 16.2 IP 65 F 5 5 3.3 250 350 350 2 250 70 1.8 500 200 3 500 200 [l/h] [gph] [l/h] [gph] [bar] [psi] DME 2 2.5 0.66 1.8 0.49 18 261 180 DME 8 7.5 1.98 5.6 1.48 10 145 180

DME

DME 12 DME 19 DME 48 12 3.71 9 2.78 6 87 180 6 3 500 200 50 0 45 0 1% 2.3 43.5 3.4 55 0.35 0.26 22.1 3.4 77 3 500 200 3 100 100 18.5 4.88 14.5 3.66 6.2 90 151 48 12.68 37 9.51 2.6 38 151

1 x 100-240 V, 50-60 Hz

CE, VDE, cULus, NSF61, PSE, TSU, GHOST

26

Technical data
DME (60-940 l/h)
Pump Maximum capacity Maximum capacity with anti-cavitation 75% Maximum capacity with anti-cavitation 50% (approx.) Maximum capacity with anti-cavitation 25% (approx.) Maximum pressure Maximum stroke frequency [stroke/min] Maximum suction lift during operation [m] Mechanical data Maximum suction lift when priming with wet valves [m] Maximum viscosity with spring-loaded valves 1 [mPas] (= cP) Maximum viscosity without spring-loaded valves Maximum liquid temperature [C] Minimum liquid temperature [C] Maximum ambient temperature [C] Minimum ambient temperature [C] Accuracy of repeatability Weight and size Weight [kg] Diaphragm diameter [mm] Supply voltage [V] Maximum current consumption [A] Electrical data Maximum power consumption P1 [W] Enclosure class Insulation class Cable data Supply cable Voltage in level sensor input [VDC] Voltage in pulse input [VDC] Signal input Minimum pulse-repetition period [ms] Impedance in analog 0/4-20 mA input [] Maximum loop resistance in pulse signal circuit [] Maximum loop resistance in level signal circuit [] Signal output Sound pressure level Approvals 1 Maximum suction lift: 1 metre. Maximum load of alarm relay output, at ohmic load [A] Maximum voltage, alarm relay output [V] The sound pressure level of the pump is lower than [dB(A)] at 100 V at 230 V 11.4 79 1.25 0.67 67.1 IP 65 B 1.5 metre 5 5 3.3 250 350 350 2 42 70 11.8 106 1[mPas] (= cP) [l/h] [l/h] [l/h] [l/h] [bar] DME 60 60 45 33.4 16.1 10 DME 150 150 112 83.5 40.4 4 160 6 1.5 3000 mPas at 50% capacity 200 50 0 45 -10 1% 21 124 2.40 1.0 240 DME 375 376 282 210 101 10

DME

DME 940 940 705 525 252 4

22.5 173

1 x 100-240 V, 50-60 Hz

DME 60-150 CE, cCSAus, PSE, GHOST DME 375-940: CE, cCSAus, GHOST

27

Technical data
DMS (0-12 l/h)
Pump DMS-A and AR, B Maximum capacity 1 DMS-D (50 Hz) DMS-D (60 Hz) Maximum pressure Maximum stroke frequency 2 [stroke/min] Maximum suction lift during operation [m] Maximum suction lift when priming with wet valves [m] Maximum viscosity with spring-loaded valves 3 [mPas] (= cP) Maximum viscosity without spring-loaded valves 3 [mPas] (= cP) Maximum liquid temperature [C] Minimum liquid temperature [C] Maximum ambient temperature [C] Minimum ambient temperature [C] Accuracy of repeatability Weight and size Weight [kg] Diaphragm diameter [mm] Supply voltage at 100 V Electrical data Maximum current consumption [A] Maximum power consumption P1 [W] Enclosure class Insulation class Voltage in level sensor input [VDC] Voltage in pulse input [VDC] Signal input Minimum pulse-repetition period [ms] Impedance in 0/4-20 mA analog input [] Maximum loop resistance in pulse signal circuit [] Maximum loop resistance in level signal circuit [] Signal output Sound pressure level Approvals 1 Irrespective of counter-pressure if the pump is calibrated to the actual installation. 2 The maximum stroke frequency varies according to calibration. 3 Maximum suction lift: 1 metre. 4 DMS-D: Only CE and VDE. Maximum load of alarm relay output at ohmic load [A] Maximum voltage, alarm relay output [V] The sound pressure level of the pump is lower than [db(A)] at 120 V at 230 V 28 32 1.8 2 500 200 50 0 45 0 1% 2.3 38 DMS-A and AR, B DMS-D (50 Hz) DMS-D (60 Hz) [l/h] [gph] [l/h] [gph] [l/h] [gph] [bar] [psi] DMS 2 2.5 0.66 3.3 20% 0.87 20% 3.9 20% 11 160 DMS 4 4 1.05 5.7 18% 1.5 18% 6.9 18% 7 102 180 187.5 225 6 3 DMS 8 7.5 1.98 8.7 8% 2.3 8% 10.4 8% 2.75 8% 5.4 78

DMS

DMS 12 12 3.71 13.7 6% 3.6 6% 16.4 6% 4.33 6% 3.4 49

1.03 20% 1.82 18%

Mechanical data

42.5

1 x 230 V 13%/+10%, 50 Hz 1 x 120 V 12%/+8%, 60 Hz 1 x 100 V 6%, 50/60 Hz 0.2 0.17 0.09 20 IP 65 F 5 5 3.3 250 350 350 2 250 70 CE, VDE, cULus, NSF61, PSE, TSU, GHOST DMS-D kun CE4

28

Pump selection
DME (0-48 l/h), standard range
Power supply: Mains plug: Valves: 1 x 100-240 V, 50-60 Hz (switch mode). EU (Schuko). Double-ball on suction side, single-ball on discharge side.

DME and DMS

Materials 2 Max. Max. Connection Control panel capacity pressure position 3 1 Pump head Gaskets Valve balls [bar] [l/h] Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted

Product number Type designation (variant A)4 Without With alarm alarm relay relay output output (variant AR) (variant A) 96434879 96434882 96443981 96443984 96434899 96434902 96437423 96437426 96434880 96434883 96443982 96443985 96434900 96434903 96437424 96437427 96434881 96434884 96443983 96443986 96434901 96434904 96437425 96437428 96434891 96434893 96443993 96443995 96434911 96434913 96437435 96437437 96434892 96434894 96443994 96443996 96434912 96434914 96437436 96437438 96434885 96434888 96443987 96443990 96434905 96434908 96437429 96437432 96434886 96434889 96443988 96443991 96434906 96434909 96437430 96437433 96434887 96434890 96443989 96443992 96434907 96434910 96437431 96437434 96434895 96434897 96443997 96443999 96434915 96434917 96437439 96437441 96434896 96434898 96443998 96444000 96434916 96434918 96437440 96437442

PP PP 2.5 (1.8) 18 PVDF SS 1.4401 PP PP 7.5 (5.6) 10 PVDF SS 1.4401 PP PP 12 (9) 6 PVDF SS 1.4401 PP PP 18.5 (14.5) 6.2 PVDF SS 1.4401 PP PP 48 (37) 2.6 PVDF SS 1.4401

EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM

Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401

4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 6/9, 9/12 6/9, 9/12 6/9, 9/12 Rp 3/8 6/9, 9/12 6/9, 9/12 6/9, 9/12 Rp 3/8

DME 2-18 A-PP/E/C-F-3111F DME 2-18 A-PP/E/C-S-3111F DME 2-18 A-PP/V/C-F-3111F DME 2-18 A-PP/V/C-S-3111F DME 2-18 A-PV/V/C-F-3111F DME 2-18 A-PV/V/C-S-3111F DME 2-18 A-SS/V/SS-F-31AAF DME 2-18 A-SS/V/SS-S-31AAF DME 8-10 A-PP/E/C-F-3111F DME 8-10 A-PP/E/C-S-3111F DME 8-10 A-PP/V/C-F-3111F DME 8-10 A-PP/V/C-S-3111F DME 8-10 A-PV/V/C-F-3111F DME 8-10 A-PV/V/C-S-3111F DME 8-10 A-SS/V/SS-F-31AAF DME 8-10 A-SS/V/SS-S-31AAF DME 12-6 A-PP/E/C-F-3111F DME 12-6 A-PP/E/C-S-3111F DME 12-6 A-PP/V/C-F-3111F DME 12-6 A-PP/V/C-S-3111F DME 12-6 A-PV/V/C-F-3111F DME 12-6 A-PV/V/C-S-3111F DME 12-6 A-SS/V/SS-F-31AAF DME 12-6 A-SS/V/SS-S-31AAF DME 19-6 A-PP/E/C-F-3122F DME 19-6 A-PP/E/C-S-3122F DME 19-6 A-PP/V/C-F-3122F DME 19-6 A-PP/V/C-S-3122F DME 19-6 A-PV/V/C-F-3122F DME 19-6 A-PV/V/C-S-3122F DME 19-6 A-SS/V/SS-F-31BBF DME 19-6 A-SS/V/SS-S-31BBF DME 48-3 A-PP/E/C-F-3122F DME 48-3 A-PP/E/C-S-3122F DME 48-3 A-PP/V/C-F-3122F DME 48-3 A-PP/V/C-S-3122F DME 48-3 A-PV/V/C-F-3122F DME 48-3 A-PV/V/C-S-3122F DME 48-3 A-SS/V/SS-F-31BBF DME 48-3 A-SS/V/SS-S-31BBF

1 Values in brackets are maximum capacity if the anti-cavitation function has been selected. 2 See list of pumped liquids on page 37. 3 Underlined sizes are factory-fitted connections; other connections are supplied with the pump as standard. 4/6, 6/9 and 9/12 are compression fittings for inner/outer tubing diameters stated in mm. Rp 1/4 and Rp 3/8 connections have internal thread for pipe connection. 4 Also available in AR-version.

29

Pump selection
DME (0-48 l/h), non-standard range
Example in bold: DME 2-18 A-SS/V/SS-F-32AAF
Maximum capacity and Control Materials of dosing head, Control panel variant gaskets and valve balls position pressure 2 [l/h] - [bar] See page 6 Motor voltage Valves Suction/discharge connection

DME and DMS

Mains plug F = EU B = USA+ CAN G = UK I = AU E = CH J = JP

Dosing head: F = Front-fitted 2 = PP = Polypropylene S = Side-fitted PV = PVDF 3= SS = Stainless steel 1.4401 Gaskets: E = EPDM V = FKMP T = PTFE Valve balls: C = Ceramic SS = Stainless steel 1.4401 T = PTFE

1x120 V, 1 = Standard 1 = Tubing 4/6+ 6/9 mm 60 Hz 2 = Spring-loaded 2 = Tubing 6/9+6/12 1x100-240 V, +9/12 mm 50-60 Hz 3 = Tubing 4/6 mm 4 = Tubing 6/9 mm 5 = Tubing 6/12 mm 6 = Tubing 9/12 mm T = Tubing 0.17"/0.25" R= Tubing 0.25"/0.375" S = Tubing 0.375"/0.5" A = Threaded Rp 1/4 B = Threaded Rp 3/8 V = Threaded 1/4" NPT Y = Threaded 3/8" NPT E = Cementing d.10 mm F = Cementing d.12 mm

DME

Pump head PP PV

Gasket

Ball 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y 2 4 5 6 A E F A B V Y 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y 2 4 5 6 A E F A B V Y

E V

C SS -F-S2 3 1 2

2-18 8-10 12-6

A AR AP1 AG1

PV

SS

E V E V

SS

-F-S-

2 3

1 2

F B G I E J

PP PV A AR AP1 AG1

C SS -F-S2 3 1 2

19-6 48-3

PV

SS

E V

SS

-F-S-

2 3

1 2

1 Pumps equipped with bus communication module, see page 15. 2 2-18: 8-10: 12-6: 19-6: 48-3: 2.5 l/h, 18 bar 7.5 l/h, 10 bar 12 l/h, 6 bar 18.5 l/h, 6.2 bar 48 l/h, 2.6 bar

30

Pump selection
DME (60-940 l/h), standard range
Power supply: Mains plug: Valves:
Max. capacity [l/h]

DME and DMS

1 x 100-240 V, 50-60 Hz switch-mode). EU (Schuko). Single-ball on suction side; single-ball on discharge side.
Control variant Materials Pump head PP PP Gaskets EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM Valve balls Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Glass Glass Glass SS 1.4401 Glass Glass Glass SS 1.4401 Control Connection panel position 19/27 25/34 19/27 25/34 19/27 25/34 Rp 3/4 19/27 25/34 19/27 25/34 19/27 25/34 Rp 3/4 19/27 25/34 19/27 25/34 19/27 25/34 Rp 3/4 19/27 25/34 19/27 25/34 19/27 25/34 Rp 3/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Product number 96524874 96524879 96524910 96524911 96524912 96524913 96524914 96524915 96524916 96524917 96524918 96524919 96524920 96524921 96524923 96524924 96524925 96524926 96524927 96524928 96524929 96524930 96524931 96524932 96524933 96524934 96524935 96524936 96524937 96524938 96524939 96524940 96524941 96524942 96524943 96524944 96524945 96524946 96524947 96524948 96524949 96524950 96524951 96524952 96524953 96524954 96524956 96524957

Max. pressure [bar]

Type designation DME 60-10 AR-PP/E/C-F-31QQF DME 60-10 AR-PP/E/C-S-31QQF DME 60-10 AR-PP/V/C-F-31QQF DME 60-10 AR-PP/V/C-S-31QQF DME 60-10 AR-PV/V/C-F-31QQF DME 60-10 AR-PV/V/C-S-31QQF DME 60-10 AR-SS/V/SS-F-31A1A1F DME 60-10 AR-SS/V/SS-S-31A1A1F DME 60-10 B-PP/E/C-F-31QQF DME 60-10 B-PP/E/C-S-31QQF DME 60-10 B-PP/V/C-F-31QQF DME 60-10 B-PP/V/C-S-31QQF DME 60-10 B-PV/V/C-F-31QQF DME 60-10 B-PV/V/C-S-31QQF DME 60-10 B-SS/V/SS-F-31A1A1F DME 60-10 B-SS/V/SS-S-31A1A1F DME 150-4 AR-PP/E/C-F-31QQF DME 150-4 AR-PP/E/C-S-31QQF DME 150-4 AR-PP/V/C-F-31QQF DME 150-4 AR-PP/V/C-S-31QQF DME 150-4 AR-PV/V/C-F-31QQF DME 150-4 AR-PV/V/C-S-31QQF DME 150-4 AR-SS/V/SS-F-31A1A1F DME 150-4 AR-SS/V/SS-S-31A1A1F DME 150-4 B-PP/E/C-F-31QQF DME 150-4 B-PP/E/C-S-31QQF DME 150-4 B-PP/V/C-F-31QQF DME 150-4 B-PP/V/C-S-31QQF DME 150-4 B-PV/V/C-F-31QQF DME 150-4 B-PV/V/C-S-31QQF DME 150-4 B-SS/V/SS-F-31A1A1F DME 150-4 B-SS/V/SS-S-31A1A1F DME 375-10 AR-PP/E/G-F-31A2A2F DME 375-10 AR-PP/E/G-S-31A2A2F DME 375-10 AR-PP/V/G-F-31A2A2F DME 375-10 AR-PP/V/G-S-31A2A2F DME 375-10 AR-PV/V/G-F-31A2A2F DME 375-10 AR-PV/V/G-S-31A2A2F DME 375-10 AR-SS/V/SS-F-31A2A2F DME 375-10 AR-SS/V/SS-S-31A2A2F DME 375-10 B-PP/E/G-F-31A2A2F DME 375-10 B-PP/E/G-S-31A2A2F DME 375-10 B-PP/V/G-F-31A2A2F DME 375-10 B-PP/V/G-S-31A2A2F DME 375-10 B-PV/V/G-F-31A2A2F DME 375-10 B-PV/V/G-S-31A2A2F DME 375-10 B-SS/V/SS-F-31A2A2F DME 375-10 B-SS/V/SS-S-31A2A2F

60

10

AR PVDF SS PP PP

60

10

B PVDF SS PP PP

150

AR PVDF SS PP PP

150

B PVDF SS PP PP

376

10

AR PVDF SS PP PP

376

10

B PVDF SS

31

Pump selection
Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted Front-fitted Side-fitted

DME and DMS

PP PP 940 4 AR PVDF SS PP PP 940 4 B PVDF SS

EPDM FKM FKM FKM EPDM FKM FKM FKM

Glass Glass Glass SS 1.4401 Glass Glass Glass SS 1.4401

Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 1/4

DME 940-4 AR-PP/E/G-F-31A2A2F DME 940-4 AR-PP/E/G-S-31A2A2F DME940-4 AR-PP/V/G-F-31A2A2F DME 940-4 AR-PP/V/G-S-31A2A2F DME 940-4 AR-PV/V/G-F-31A2A2F DME 940-4 AR-PV/V/G-S-31A2A2F DME 940-4 AR-SS/V/SS-F-31A2A2F DME 940-4 AR-SS/V/SS-S-31A2A2F DME 940-4 B-PP/E/G-F-31A2A2F DME 940-4 B-PP/E/G-S-31A2A2F DME 940-4 B-PP/V/G-F-31A2A2F DME 940-4 B-PP/V/G-S-31A2A2F DME 940-4 B-PV/V/G-F-31A2A2F DME 940-4 B-PV/V/G-S-31A2A2F DME 940-4 B-SS/V/SS-F-31A2A2F DME 940-4 B-SS/V/SS-S-31A2A2F

96524958 96524959 96524960 96524961 96524962 96524963 96524964 96524965 96524966 96524967 96524968 96524969 96524980 96524981 96524982 96524983

19/27, 25/34, 32/41 and 38/48 are inner/outer tubing diameters in mm for hose clamp connectors. Rp 3/4 and Rp 1 1/4 connections have internal thread for pipe connection.

32

Pump selection
DME (60-940 l/h), non-standard range
Example in bold: DME 150-4 AR SS/V/SS-F-32A1A1F
Maximum capacity and pressure 2 [l/h] - [bar] Control variant Materials of dosing head, gaskets and valve balls Control panel position Motor voltage Valves

DME and DMS

Connection suction/ discharge

Mains plug

See page 6

Dosing head: PP = Polypropylene PV = PVDF SS = Stainless steel 1.4401 Gaskets: E = EPDM V = FKM T = PTFE Valve balls: C = Ceramic SS = Stainless steel 1.4401 Y = Hastelloy C G = Glass T = PTFE Pump head PP PV

F = Front-fitted 2 = 1 x 120 V, 1 = Standard S = Side-fitted 60 Hz 2 = Spring-loaded 3 = 1 x 100-240 V, 50-60 Hz

Q =19/27+ 25/34 mm A1 =Threaded, Rp 3/4 A2 =Threaded, Rp 1 1/4 A3 =Threaded 3/4" NPT A4 =Threaded 1 1/4" NPT

F = EU (DIN) B = USA+CAN G = UK I = AU E = CH J = JP

DME

Gasket E V

Ball C SS Y G T Y SS C SS Y G T Y SS -F-S2 3 1 2 A2 A4 -F-S2 3 1 2

60-10 150-4

B AR AP1

PV SS

T E V E V

Q A1 A3 F B G I E J

375-10 940-4

B AR AP1

PP PV

PV SS

T E V

1 Pumps equipped with bus communication module, see page 15. 2 60-10: 60 l/h, 10 bar 150-4: 150 l/h, 4 bar 375-10: 375 l/h, 10 bar 940-4: 940 l/h, 4 bar

33

Pump selection
DMS (0-12 l/h), standard range
Power supply: Mains plug: Valves:
Max.pressure [bar] Max.capacity [l/h]

DME and DMS

1 x 230 V, 50 Hz. EU (Schuko). Double-ball on suction side, single-ball on discharge side.


Materials 2 Product number Connection Pump head Gaskets Valve balls Control panel position Type designation (variants A4 and B)

Control variant

3

Without alarm relay (variant A)

With alarm relay (variant AR)

Variant D

PP PP A AR PVDF 2.5 SS 1.4401 11 B PP PP PVDF SS 1.4401 PP 3.3 D PP PVDF SS 1.4401 PP PP A AR PVDF 4 SS 1.4401 7 B PP PP PVDF SS 1.4401 PP 5.7 D PP PVDF SS 1.4401 PP PP A AR PVDF 7.5 SS 1.4401 5.4 B PP PP PVDF SS 1.4401 PP 8.7 D PP PVDF SS 1.4401

EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM

Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401

4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4

Front-fitted DMS 2-11 A-PP/E/C-F-1111F Side-fitted Side-fitted Side-fitted Side-fitted DMS 2-11 A-PP/E/C-S-1111F DMS 2-11 A-PP/V/C-S-1111F DMS 2-11 A-PV/V/C-S-1111F DMS 2-11 A-SS/V/SS-S-11AAF Front-fitted DMS 2-11 A-PP/V/C-F-1111F Front-fitted DMS 2-11 A-PV/V/C-F-1111F Front-fitted DMS 2-11 A-SS/V/SS-F-11AAF Front-fitted DMS 2-11 B-PP/E/C-F-1111F Front-fitted DMS 2-11 B-PP/V/C-F-1111F Front-fitted DMS 2-11 B-PV/V/C-F-1111F Front-fitted DMS 2-11 B-SS/V/SS-F-11AAF x x x x Side-fitted Side-fitted Side-fitted Side-fitted DMS 2-11 D-PP/E/C-X-1111F DMS 2-11 D-PP/V/C-X-1111F DMS 2-11 D-PV/V/C-X-1111F DMS2-11 D-SS/V/SS-X-11AAF

96437450 96437451 96443969 96443970 96437458 96437459 96437466 96437467 96437474 96443977 96437478 96437482

96446959 96446960 96446961 96446962 96446963 96446964 96446965 96446966 96476529 96476532 96476533 96476534

Front-fitted DMS 4-7 A-PP/E/C-F-1111F DMS 4-7 A-PP/E/C-S-1111F DMS 4-7 A-PP/V/C-S-1111F DMS 4-7 A-PV/V/C-S-1111F DMS 4-7 A-SS/V/SS-S-11AAF Front-fitted DMS 4-7 A-PP/V/C-F-1111F Front-fitted DMS 4-7 A-PV/V/C-F-1111F Front-fitted DMS 4-7 A-SS/V/SS-F-11AAF Front-fitted DMS 4-7 B-PP/E/C-F-1111F Front-fitted DMS 4-7 B-PP/V/C-F-1111F Front-fitted DMS 4-7 B-PV/V/C-F-1111F Front-fitted DMS 4-7 B-SS/V/SS-F-11AAF x x x x Side-fitted Side-fitted Side-fitted Side-fitted DMS 4-7 D-PP/E/C-X-1111F DMS 4-7 D-PP/V/C-X-1111F DMS 4-7 D-PV/V/C-X-1111F DMS 4-7 D-SS/V/SS-X-11AAF

96437452 96437453 96443971 96443972 96437460 96437461 96437468 96437469 96437475 96443978 96437479 96437483

96446967 96446968 96446969 96446970 96446971 96446972 96446973 96446974 96476535 96476536 96476537 96476538

Front-fitted DMS 8-5 A-PP/E/C-F-1111F DMS 8-5 A-PP/E/C-S-1111F DMS 8-5 A-PP/V/C-S-1111F DMS 8-5 A-PV/V/C-S-1111F DMS 8-5 A-SS/V/SS-S-11AAF Front-fitted DMS 8-5 A-PP/V/C-F-1111F Front-fitted DMS 8-5 A-PV/V/C-F-1111F Front-fitted DMS 8-5 A-SS/V/SS-F-11AAF Front-fitted DMS 8-5 B-PP/E/C-F-1111F Front-fitted DMS 8-5 B-PP/V/C-F-1111F Front-fitted DMS 8-5 B-PV/V/C-F-1111F Front-fitted DMS 8-5 B-SS/V/SS-F-11AAF x x x x DMS 8-5 D-PP/E/C-X-1111F DMS 8-5 D-PP/V/C-X-1111F DMS 8-5 D-PV/V/C-X-1111F DMS 8- 5 D-SS/V/SS-X-11AAF

96437454 96437455 96443973 96443974 96437462 96437463 96437470 96437471 96437476 96443979 96437480 96437484

96446975 96446976 96446977 96446978 96446979 96446980 96446981 96446982 96476540 96476541 96476542 96476543

34

Pump selection
Max.pressure [bar] Materials 2 Control variant Connection Pump head Gaskets Valve balls Control panel position Type designation (variants A4 and B)

DME and DMS

Max.capacity [l/h]

Product number

3

Without alarm relay (variant A)

With alarm relay (variant AR)

Variant D

PP PP A AR PVDF 12 SS 1.4401 3.4 B PP PP PVDF SS 1.4401 PP 13.7 D PP PVDF SS 1.4401

EPDM FKM FKM FKM EPDM FKM FKM FKM EPDM FKM FKM FKM

Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401 Ceramic Ceramic Ceramic SS 1.4401

4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4 4/6, 6/9 4/6, 6/9 4/6, 6/9 Rp 1/4

Front-fitted DMS 12-3 A-PP/E/C-F-1111F Side-fitted Side-fitted Side-fitted Side-fitted DMS 12-3 A-PP/E/C-S-1111F DMS 12-3 A-PP/V/C-S-1111F DMS 12-3 A-PV/V/C-S-1111F DMS 12-3 A-SS/V/SS-S-11AAF Front-fitted DMS 12-3 A-PP/V/C-F-1111F Front-fitted DMS 12-3 A-PV/V/C-F-1111F Front-fitted DMS 12-3 A-SS/V/SS-F-11AAF Front-fitted DMS 12-3 B-PP/E/C-F-1111F Front-fitted DMS 12-3 B-PP/V/C-F-1111F Front-fitted DMS 12-3 B-PV/V/C-F-1111F Front-fitted DMS 12-3 B-SS/V/SS-F-11AAF x x x x DMS 12-3 D-PP/E/C-X-1111F DMS 12-3 D-PP/V/C-X-1111F DMS 12-3 D-PV/V/C-X-1111F DMS 12-3 D-SS/V/SS-X-11AAF

96437456 96437457 96443975 96443976 96437464 96437465 96437472 96437473 96437477 96443980 96437481 96437485

96446951 96446952 96446953 96446954 96446955 96446956 96446957 96446958 96473184 96476544 96476545 96476546

See description of control variants on page 6.

2 See list of pumped liquids on page 37. 3 Underlined sizes are factory-fitted connections; other sizes are supplied with the pump as standard. 4/6 and 6/9 are compression fittings for inner/outer tubing diameters stated in mm. Rp 1/4 connection have internal thread for pipe connection. 4 Also available in AR version.

35

Pump selection
DMS (0-12 l/h), non-standard range
Example in bold: DMS 4-7 A-PP/V/C-S-1244F
Max. capacity and Control Materials of dosing head, Control panel variant gaskets and valve balls position pressure2 [l/h] - [bar] See page 6 Motor voltage Valves 1 = Standard 2 = Springloaded

DME and DMS

Suction/discharge connection 1 = Tubing 4/6+6/9 mm 2 = Tubing 6/9+6/12 +9/12 mm 3 = Tubing 4/6 mm 4 = Tubing 6/9 mm 5 = Tubing 6/12 mm 6 = Tubing 9/12 mm T = Tubing 0.17"/0.25" R = Tubing 0.25"/0.375" S = Tubing 0.375"/0.5" A = Threaded Rp 1/4 B = Threaded Rp 3/8 B = Threaded Rp 3/8 V = Threaded 1/4 NPT Y = Threaded 3/8 NPT E = Cementing d.10 mm F = Cementing d.12 mm

Mains plug F = EU B = USA+CAN G = UK I = AU E = CH J = JP

Dosing head: F = Front-fitted 1 = 1 x 230 V, PP = Polypropylene S = Side-fitted 50 Hz PV = PVDF X = No control 2 = 1 x 120 V, SS = Stainless steel 1.4401 panel 60 Hz Gaskets: E = EPDM V = FKM T = PTFE Valve balls: C = Ceramic SS = Stainless steel 1.4401 T = PTFE

DMS

Pump head

Gasket

Ball 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y 1 2 3 4 5 6 T R S A (PVC) E (PVC) F (PVC) A B V Y

PP PV

E V

LC SS -F-S1 2 1 2

AAR

PV

F B G I E J

SS

E V

SS

-F-S-

1 2

1 2

PP PV

E V

C SS 1 2 1 2

2-11 4-7 8-5 12-3

-FB PV T T

F B G I E J

SS

E V

SS

-F-

1 2

1 2

PP PV

E V

C SS -X1 2 1 2

D PV T T

F J

SS 2 2-11: 4-7: 8-5: 12-3:

E V

SS

-X-

1 2

1 2

2.5 l/h, 11 bar 4 l/h, 7 bar 7.5 l/h, 5.4 bar 12 l/h, 3.4 bar

36

Pumped liquids
List of pumped liquids
The resistance table below is intended as a general guide for material resistance (at room temperature), and does not replace testing of the chemicals and pump materials under specific working conditions.

DME and DMS

The data shown are based on information from various sources available, but many factors (purity, temperature, abrasive particles, etc.) may affect the chemical resistance of a given material. Note: Some of the liquids in this table may be toxic, corrosive or hazardous. Note: Please be careful when handling these liquids.

Pumped liquid (20C)

Materials Pump housing SS 1.4401 Concentration % PP 25 20 10 30 40 50 30 100 100 100 50 < 25 25-37 30 10 30 40 70 5 50 10 30 30 20 20 30 50 20 30 20 6 < 80 80-98 Gasket Cen tellen C Ceramic Ball

EPDM

Acetic acid Aluminium chloride Aluminium sulphate Ammonia, aqueous Calcium hydroxide 7 Calcium hypochlorite

CH3COOH AlCl3 Al2(SO4)3 NH4OH Ca(OH)2 Ca(OCl)2

60 85 40 60 28

Chromic acid 5

H2CrO4

Copper sulphate Ferric chloride3 Ferric sulphate3 Ferrous chloride Ferrous sulphate Hydrochloric acid Hydrogen peroxide

CuSO4 FeCl3 Fe2(SO4)3 FeCl2 FeSO4 HCl H2O 2

Nitric acid

HNO3

Peracetic acid Potassium hydroxide Potassium permanganate Sodium chlorate Sodium chloride Sodium chlorite Sodium hydroxide Sodium hypochlorite Sodium sulphide Sodium sulphite 6 Sulphurous acid Sulphuric acid4 Resistant. Limited resistance. Not resistant.

CH3COOOH KOH KMnO4 NaClO3 NaCl NaClO2 NaOH NaOCl Na2S Na2SO3 H2SO3 H2SO4

3 Risk of crystallisation. 4 Reacts violently with water and generates much heat. (Pump should be absolutely dry before dosing sulphuric acid.) 5 Must be fluoride-free when glass balls are used. 6 In neutral solutions. 7 Saturated solution 0.1%.

Glass

PVDF

PTFE

Description

CSM

FKM

PVC

Chemical formula

37

Further product documentation

DME and DMS

WebCAPS
WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185 000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings.

Catalogue With a starting point in areas of applications and pump types, this section contains technical data curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc.

Literature In this section you can access all the lastest documents of a given pump, such as data booklets Installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures, etc.

Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and cancelled Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts.

38

Further product documentation

DME and DMS

Sizing

With a starting point in different application areas and installation examples, this section gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, lifecycle costs, etc. analyse your selected pump via the built-in lifecycle cost tool determine the flow velocity in wastewater applications, etc.

Replacement In this section you find a guide to select and compare replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. After having specified the installed pump, the guide suggests a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings In this section it is possible to download 2-dimensional (2D) and 3dimensional (3D) CAD drawings of most Grundfos pumps. The following formats are available in WebCAPS: 2-dimensional drawings .dxf, wireframe drawings .dwg, wireframe drawings. 3-dimensional drawings .dwg, wireframe drawings (without surfaces) .stp, solid drawings (with surfaces) .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed informtion on more than 185,000 Grundfos products in more than 22 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year.
Fig. 26 WinCAPS CD-ROM

39

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

V7164097 0107
Repl. V7164097 0305

GB
Subject to alterations.

Grundfos Management A/S


Poul Due Jensens Vej 7 DK-8850 Bjerringbro

Grundfos Alldos Dosing & Disinfection


Alldos Eichler GmbH Reetzstrasse 85 D-76327 Pfinztal (Sllingen) Telephone: +49 72 40 61 0

Telephone: +45 87 50 14 00 www.grundfosalldos.com