Cambium: PMP 400/430 Series Networks PTP 200/230 Series Bridges
Cambium: PMP 400/430 Series Networks PTP 200/230 Series Bridges
Cambium
PMP 400/430 Series Networks PTP 200/230 Series Bridges
Page 1 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Accuracy
While reasonable efforts have been made to assure the accuracy of this document, Cambium Networks assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. Cambium Networks reserves the right to make changes to any products described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Cambium Networks does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It is possible that this publication may contain references to, or information about Cambium Networks products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Cambium Networks intends to announce such Cambium Networks products, programming, or services in your country.
Copyrights
This document, Cambium Networks products, and 3rd Party Software products described in this document may include or describe copyrighted Cambium Networks and other 3rd Party supplied computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Cambium Networks, its licensors, and other 3rd Party supplied software certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Cambium Networks, its licensors, or the 3rd Party software supplied material contained in the Cambium Networks products described in this document may not be copied, reproduced, reverse engineered, distributed, merged or modified in any manner without the express written permission of Cambium Networks. Furthermore, the purchase of Cambium Networks products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Cambium Networks or other 3rd Party supplied software, except for the normal non-exclusive, royalty free license to use that arises by operation of law in the sale of a product.
Restrictions
Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Cambium Networks
License Agreements
The software described in this document is the property of Cambium Networks and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement.
Page 2 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table of Contents
Table of Contents ..................................................................................................................................... 3 List of Tables ............................................................................................................................................ 5 List of Figures........................................................................................................................................... 6 List of Procedures .................................................................................................................................... 7
Page 3 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Spectrum Analyzer ..................................................................................................................................42 Collocation of 5.8 GHz OFDM with Standard 5.7 GHz Canopy FSK .......................................................43 Channel Spacing .....................................................................................................................................43 Frame Calculations and Configuration Settings ......................................................................................43 Collocation of 5.4 GHz OFDM with Standard 5.4 GHz Canopy FSK .......................................................44 Channel Spacing .............................................................................................................................44 Frame Calculations and Configuration Settings ...............................................................................44
Page 4 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
List of Tables
Table 1: Cambium PMP 400/430 and PTP 200/230 Series ...........................................................................17 Table 2: 5.8GHz OFDM - PMP 430 and PTP 230 Series Model Number Descriptions .................................17 Table 3: 5.4GHz OFDM - PMP 430 Series Model Number Descriptions .......................................................19 Table 4: 5.4GHz OFDM - PMP 400 and PTP 200/230 Model Number Descriptions ......................................20 Table 5: 4.9GHz OFDM - PMP 400 and PTP 200 Model Number Descriptions.............................................21 Table 6: CMM4 56VDC and 30 VDC Operation .............................................................................................22 Table 7: Ancillary Equipment and Model Numbers ........................................................................................25 Table 8: Performance Details.........................................................................................................................37 Table 9: 5.8 GHz Channel Center Frequencies, by Region ...........................................................................39 Table 10: 5.4 GHz Channel Center Frequencies, by Region .........................................................................40 Table 11: 4.9 GHz Channel Center Frequencies ...........................................................................................41 Table 12: PMP 400/430 and PTP 200/230 Tx output power ..........................................................................48 Table 13: PMP 400/430 AP Control Slot Settings ..........................................................................................51 Table 14: 5.4 / 5.8 GHz OFDM DFS Operation based on Region Code ........................................................52 Table 15: US FCC IDs and Industry Canada Certification Numbers and Covered Configurations ................69 Table 16: Disclosure Table ............................................................................................................................75 Table 17: Exposure Separation Distances .....................................................................................................75 Table 18: Calculated Exposure Distances and Power Compliance Margins ..................................................76
Page 5 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
List of Figures
Figure 1: PMP 430 CAP 54430 & 58430 ........................................................................................................ 8 Figure 2: PMP 400 CAP 54400 - 5.4 GHz....................................................................................................... 8 Figure 3: PMP 400 CAP 49400 - 4.9 GHz....................................................................................................... 8 Figure 4: PMP 430 CSM 54430 & 58430 ........................................................................................................ 8 Figure 5: PMP 400 CSM 54400 - 5.4GHz ....................................................................................................... 8 Figure 6: PMP 400 CSM 49400 - 4.9 GHz ...................................................................................................... 8 Figure 7: PTP 200 Integrated .......................................................................................................................... 9 Figure 8: PTP 200 Connectorized ................................................................................................................... 9 Figure 9: PTP 230 Integrated .......................................................................................................................... 9 Figure 10: CMM4 56 VDC Power Supply .......................................................................................................23 Figure 11: CMMmicro and CMM4 30 VDC Power Supply..............................................................................23 Figure 12: CMM4 56 VDC Rackmount Power Supply ....................................................................................23 Figure 13: CMM4 - 56 VDC and 30 VDC terminal blocks ..............................................................................23 Figure 14: 600SS Surge Suppression AP and SM diagram ...........................................................................24 Figure 15: LOS, nLOS, and NLOS .................................................................................................................29 Figure 16: AP Grounding Lug ........................................................................................................................31 Figure 17: 600SS pole mount kit ....................................................................................................................31 Figure 18: PMP 430 SM .................................................................................................................................34 Figure 19: PMP 430 SM with Optional LENS .................................................................................................34 Figure 20: PMP 400 and PTP 200 radio with integrated antenna ..................................................................35 Figure 21: PMP 400/430 and PTP 200 BH connectorized radio ....................................................................35 Figure 22: CAP 49400 ...................................................................................................................................36 Figure 23: CAP 58430 and 54430 ..................................................................................................................36 Figure 24: PMP 430 spectrum analysis compared to FSK .............................................................................42 Figure 25: Dynamic Rate Adapt on AP "Configuration => General" page ......................................................47 Figure 26: SM Power Level on AP Home => Session Status page. ............................................................49 Figure 27: Max Range & Downlink Data on AP "Configuration => Radio" page. ...........................................50 Figure 28: DFS Status on AP "Home => DFS Status" page. .........................................................................52 Figure 29: Region Code on AP Configuration => General page ..................................................................55 Figure 30: Ground lug highlighted on AP .......................................................................................................65 Figure 31: Dielectric Grease Apply to RJ45 connector ...............................................................................66 Figure 32: Dielectric Grease - Insert Ethernet Cable .....................................................................................67
Page 6 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
List of Procedures
Procedure 1-1 Reporting Problems................................................................................................................11 Procedure 2: Finding collocation values using Frame Calculators .................................................................45 Procedure 3: Assembling a 5.8 or 5.4 GHz AP, and attaching to tower .........................................................60 Procedure 4: Assembling a 4.9 GHz AP, and attaching to tower ...................................................................62 Procedure 5: Cabling and Grounding/Earthing the AP ...................................................................................65
Page 7 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Chapter 1: Introduction
This guide provides product configuration information specific to the PMP 400/430 Series networks and PTP 200/230 Series bridges in 5.8-GHz, 5.4-GHz and 4.9-GHz bands. Note: PMP 400 5.4-GHz Series is replaced with PMP 430 5.4-GHz Series. PMP 430 Series 5.4 & 5.8 GHz PMP 400 Series 5.4 GHz PMP 400 Series 4.9 GHz
Figure 6: PMP 400 CSM 49400 - 4.9 GHz Integrated and Connectorized
Page 8 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
This guide should be used along with the PMP Solutions User Guide, which covers general information, including all network features, RF control features, and GUI (Graphical User Interface) features common across PMP 100, 400, and 500 Series networks and PTP 100 and 200 Series bridges. The PMP Solutions User Guide is available from the PMP Software and Documentation section of the Cambium Document Library, http://www.cambiumnetworks.com/support/pmp/software. This guide assumes that the reader has general RF (Radio Frequency) and Internet Protocol (IP) knowledge and background. This issue is consistent with features provided by Canopy Release 11.2. Separate Release Notes for each release are available and include open issues and other important information specific to each release. R11.2 software and software release notes can be downloaded from the Cambium support web site: http://www.cambiumnetworks.com/support/pmp/software.
Page 9 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
General information
Version information
The following shows the issue status of this document since it was first released. Issue 1 2 3 4 Date of issue JAN 2012 FEB 2012 MAR 2012 APR 2012 Initial release Updates to PTP 230 performance data Updates to power density details Updates to CMM4 radio powering details Description
Purpose
Cambium Networks documents are intended to instruct and assist personnel in the operation, installation and maintenance of the Cambium equipment and ancillary devices. It is recommended that all personnel engaged in such activities be properly trained. Cambium disclaims all liability whatsoever, implied or express, for any risk of damage, loss or reduction in system performance arising directly or indirectly out of the failure of the customer, or anyone acting on the customer's behalf, to abide by the instructions, system parameters, or recommendations made in this document.
Page 10 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Cross references
References to external publications are shown in italics. Other cross references, emphasized in blue text in electronic versions, are active links to the references. This document is divided into numbered chapters that are divided into sections. Sections are not numbered, but are individually named at the top of each page, and are listed in the table of contents.
Feedback
We appreciate feedback from the users of our documents. This includes feedback on the structure, content, accuracy, or completeness of our documents. Send feedback to email support (see Contacting Cambium Networks).
Procedure 1-1 Reporting Problems 1 2 3 4 Search this document and the software release notes of supported releases Visit the support website (http://www.cambiumnetworks.com/support) Ask for assistance from the Cambium product supplier Gather information from affected units such as: The IP addresses, MAC addresses, and product Serial Numbers The software releases The configuration of software features Any available diagnostic downloads, including CNUT Customer Support Tool output 5 Escalate the problem by emailing or telephoning support
See Contacting Cambium Networks for URLs, email addresses and telephone numbers.
Page 11 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Warranty
Cambiums standard hardware warranty is for one (1) year from date of shipment from Cambium or a Cambium distributor. Cambium warrants that hardware will conform to the relevant published specifications and will be free from material defects in material and workmanship under normal use and service. Cambium shall within this time, at its own option, either repair or replace the defective product within thirty (30) days of receipt of the defective product. Repaired or replaced product will be subject to the original warranty period but not less than thirty (30) days.
To register products or activate warranties, visit the support website. For warranty assistance, contact the reseller or distributor.
Using non-Cambium parts for repair could damage the equipment or void warranty. Contact Cambium for service and repair instructions.
Portions of Cambium equipment may be damaged from exposure to electrostatic discharge. Use precautions to prevent damage.
Security Advice
Cambium Networks systems and equipment provide security parameters that can be configured by the operator based on their particular operating environment. Cambium recommends setting and using these parameters following industry recognized security practices. Security aspects to be considered are protecting the confidentiality, integrity, and availability of information and assets. Assets include the ability to communicate, information about the nature of the communications, and information about the parties involved.
In certain instances Cambium makes specific recommendations regarding security practices, however the implementation of these recommendations and final responsibility for the security of the system lies with the operator of the system. Upon equipment release from manufacturing, some software parameters may be set to an insecure setting to ease field deployment and initial device management.
Page 12 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Warnings
Warnings precede instructions that contain potentially hazardous situations. Warnings are used to alert the reader to possible hazards that could cause loss of life or physical injury. A warning has the following format:
Warning text and consequence for not following the instructions in the warning.
Cautions
Cautions precede instructions and are used when there is a possibility of damage to systems, software, or individual items of equipment within a system. However, this damage presents no danger to personnel. A caution has the following format:
Caution text and consequence for not following the instructions in the caution.
Notes
A note means that there is a possibility of an undesirable situation or provides additional information to help the reader understand a topic or concept. A note has the following format:
Note text.
Abbreviations
The following abbreviations may be used in these notes: 1X 2X 3X AAA AES AP BH BHM BHS CAP 1X (QPSK) modulation 2X (16 QAM) modulation 3X (64 QAM) modulation Authentication, Authorization, and Accounting Advanced Encryption Standard Access Point Module Backhaul Module, either timing master or timing slave Backhaul Module Master Backhaul Module Slave Access Point Module
Page 13 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
CIR CMM CNUT CSM DES DFS DHCP DiffServ EIRP ETSI EU FCC FSK GHz GPS LoS MIB MIR NAT nLoS NLoS OFDM PMP PPS PTP QAM QPSK RADIUS RF SM VDC VLAN VSA
Committed Information Rate Cluster Management Module (CMM4 or CMMicro) Canopy Network Updater Tool Subscriber Module Data Encryption Standard Dynamic Frequency Selection for radar avoidance Dynamic Host Configuration Protocol Differentiated Services Equivalent Isotropically Radiated Power European Telecommunications Standards Institute European Union Federal Communications Commission (United States) Frequency Shift Keying Gigahertz Global Positioning System Note: CMM uses GPS to synchronize APs & BHs Line of Sight Management Information Base for SNMP Maximum Information Rate Network Address Translation Near Line of Sight Non Line of Sight Orthogonal Frequency Division Multiplexing Point-to-Multi-Point (AP to SMs) Packet Per Second Point-to-Point (Backhauls) Quadrature Amplitude Modulation Quadrature Phase Shift Keying Remote Authentication Dial-In User Service Radio Frequency Subscriber Module Volts Direct Current Virtual Local Area Network Vendor-Specific Attribute
Page 14 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Security Advice
Cambium Networks systems and equipment provide security parameters that can be configured by the operator based on their particular operating environment. Cambium recommends setting and using these parameters following industry recognized security practices. Security aspects to be considered are protecting the confidentiality, integrity, and availability of information and assets. Assets include the ability to communicate, information about the nature of the communications, and information about the parties involved.
In certain instances Cambium makes specific recommendations regarding security practices, however the implementation of these recommendations and final responsibility for the security of the system lies with the operator of the system.
Page 15 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
PMP 400/430 Series networks and PTP 200/230 Series bridges add OFDM-based (Orthogonal Frequency Division Multiplexing) products to the Canopy family. PMP 430 5.4 and 5.8-GHz SMs as shown in Figure 4 on page 8 use the Canopy SM form factor with an integrated antenna. PMP 400 5.4-GHz SMs as shown in Figure 5 on page 8 are available with either an integrated antenna or an external N-type connector on a short length of coaxial cable for connecting to a connectorized antenna. PMP 400 5.4-GHz AP and PMP 430 5.4 and 5.8-GHz APs as shown on page 8 are always connectorized, and sold either as a radio with a connectorized antenna as a kit, or as a radio with an external N-type connector on a short length of coaxial cable for connecting to an operatorprovided antenna. U.S. customers must use the kit version since the FCC requires the radio to be regulatory certified with the connectorized antenna. PTP 200 5.4 and 4.9-GHz BHs as shown in Figure 7 and Figure 8 on page 9 are available with either an integrated antenna or an external N-type connector on a short length of coaxial cable for connecting to a connectorized antenna. PTP 230 5.4 and 5.8-GHz BHs as shown in Figure 9 on page 9 use the Canopy SM form factor with an integrated antenna. PMP 400/430 Series networks are available in multiple bands: PMP 58430 APs and SM provide connectivity in the unlicensed 5.8 GHz band. PMP 54430 APs and SMs provide connectivity in the unlicensed 5.4 GHz band. PMP 54400 APs and SMs provide connectivity in the unlicensed 5.4 GHz band. PMP 49400 APs and SMs provide connectivity in the licensed 4.9 GHz band allocated to public safety services. State and local governmental entities are eligible to hold 4.9 GHz licenses. PTP 200/230 Series networks are available in multiple bands: PTP 54200 BHs provide connectivity in the unlicensed 5.4 GHz band. PTP 49200 BHs provide connectivity in the licensed 4.9 GHz band allocated to public safety services. State and local governmental entities are eligible to hold 4.9 GHz licenses. PTP 54230 BHs provide connectivity in the unlicensed 5.4 GHz band. PTP 58230 BHs provide connectivity in the unlicensed 5.8 GHz band.
Page 16 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table 1 shows the Cambium PMP 400/430 Series and PTP 200/230 Series of products by frequency band, channel bandwidth, cyclic prefix and current software version. Table 1: Cambium PMP 400/430 and PTP 200/230 Series Frequency PMP Series (Point-toMultiPoint) PMP 430 Series - 58430 5.8 GHz PTP Series (Point-To-Point) PTP 230 Series -58230 Channel Bandwidth PMP Series 5, 10 or 20MHz PTP Series 10 or 20MHz Cyclic Prefix Software Version PMP Series 11.2 PTP Series 11.2
PMP 430 Series - 54430 PMP 400 Series - 54400 PMP 400 Series - 49400
PTP 230 Series -54230 PTP 200 Series - 54200 PTP 200 Series 49200 -
Table 2 shows the Cambium PMP 430 Series (5.8 GHz OFDM) AP and SM models. Table 2: 5.8GHz OFDM - PMP 430 and PTP 230 Series Model Number Descriptions CSM 58430 Model Number 5790SM4 5791SM4 5790SM10 5791SM10 5790SM20 5791SM20 5790SM40 5791SM40 5.8GHz OFDM Subscriber Module (SM) Description 5.8 GHz OFDM SM 4 Mbps 5.8 GHz OFDM SM 4 Mbps 5.8 GHz OFDM SM 10 Mbps 5.8 GHz OFDM SM 10 Mbps 5.8 GHz OFDM SM 20 Mbps 5.8 GHz OFDM SM 20 Mbps 5.8 GHz OFDM SM Uncapped 5.8 GHz OFDM SM Uncapped Power 29.5 VDC Supply Type Specs in Section 2.6.2 2.6.2 2.6.2 2.6.2 2.6.2 2.6.2 Refer to Table 7 for Models 2.6.2 2.6.2
Picture
Page 17 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
5.8GHz OFDM Access Point (AP) Description 5.8 GHz OFDM Connectorized AP w/antenna 5.8 GHz OFDM Connectorized AP w/antenna - US Model 5.8 GHz OFDM Connectorized AP w/antenna 5.8 GHz OFDM Connectorized AP w/antenna - US Model 5.8 GHz OFDM Connectorized AP No antenna 5.8 GHz OFDM Connectorized AP - No antenna 5.8GHz OFDM Backhaul (BH) Description 5.8 GHz OFDM BH 10 Mbps
Encryption
Picture
CMM Type Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply
DES
2.6.5
5780APUS
DES
2.6.5
5781AP
AES
2.6.5
5781APUS
AES
2.6.4
5780APC
DES
2.6.4
AES
Encryption
Picture
CMM Type
CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply
DES
5780BH20
5.8 GHz OFDM BH 20 Mbps 5.8 GHz OFDM BH Uncapped 5.8 GHz OFDM BH 10 Mbps
DES
2.6.6
5780BH50
DES
2.6.6
5781BH10
AES
2.6.6
5781BH20
AES
2.6.6
5781BH50
AES
2.6.6
Page 18 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table 3 shows the Cambium PMP 430 Series (5.4 GHz OFDM) AP and SM models. Table 3: 5.4GHz OFDM - PMP 430 Series Model Number Descriptions CSM 54430 Model Number 5490SM4 5491SM4 5490SM10 5491SM10 5490SM20 5491SM20 5490SM40 5491SM40 CAP 54430 Model Number 5480AP 5.4GHz OFDM Subscriber Module (SM) Description 5.4 GHz OFDM SM 4 Mbps 5.4 GHz OFDM SM 4 Mbps 5.4 GHz OFDM SM 10 Mbps 5.4 GHz OFDM SM 10 Mbps 5.4 GHz OFDM SM 20 Mbps 5.4 GHz OFDM SM 20 Mbps 5.4 GHz OFDM SM Uncapped 5.4 GHz OFDM SM Uncapped 5.4GHz OFDM Access Point (AP) Description 5.4 GHz OFDM Connectorized AP w/antenna 5.4 GHz OFDM Connectorized AP w/antenna - US Model 5.4 GHz OFDM Connectorized AP w/antenna 5.4 GHz OFDM Connectorized AP w/antenna - US Model 5.4 GHz OFDM Connectorized AP No antenna 5.4 GHz OFDM Connectorized AP - No antenna Power 29.5 VDC Supply Type Specs in Section 2.6.2 2.6.2 2.6.2 2.6.2 2.6.2 2.6.2 Refer to Table 7 for Models 2.6.2 2.6.2 Picture CMM Type Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Specs in Section 2.6.5
Encryption DES AES DES AES DES AES DES AES Encryption
Picture
DES
2.6.5
5480APUS*
DES
2.6.5
5481AP
AES
2.6.5
5481APUS*
AES
2.6.4
5480APC
DES
2.6.4
5481APC
AES
Page 19 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table 4 shows the Cambium PMP 400 and PTP 200/230 Series (5.4 GHz OFDM) models available. Table 4: 5.4GHz OFDM - PMP 400 and PTP 200/230 Model Number Descriptions CSM 54400 Model Number 5440SM 5441SM 5440SMC 5441SMC CAP 54400 Model Number 5440AP 5440APUS 5441AP 5.4 GHz OFDM Subscriber Module (SM) Description 5.4 GHz OFDM SM 5.4 GHz OFDM SM 5.4 GHz OFDM Connectorized SM 5.4 GHz OFDM Connectorized SM 5.4 GHz OFDM Access Point (AP) Description 5.4 GHz OFDM Connectorized AP w/antenna 5.4 GHz OFDM Connectorized AP w/antenna - US Model 5.4 GHz OFDM Connectorized AP w/antenna 5.4 GHz OFDM Connectorized AP w/antenna - US Model 5.4 GHz OFDM Connectorized AP No Antenna 5.4 GHz OFDM Connectorized AP No Antenna 5.4 GHz OFDM Backhaul (BH) Description 5.4 GHz OFDM BH 5.4 GHz OFDM BH US Model 5.4 GHz OFDM BH 5.4 GHz OFDM BH US Model 5.4 GHz OFDM Connectorized BH 5.4 GHz OFDM Connectorized BH US Model 5.4 GHz OFDM Connectorized BH DES or AES DES AES DES AES DES or AES DES DES AES Refer to Table 7 for Models Power 29.5 VDC Supply Type Specs in Section 2.6.3 2.6.3 2.6.4 2.6.4 Specs in Section Appendix Appendix Appendix
Picture
Picture
CMM Type
CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply
5441APUS
AES
Appendix
5440APC 5441APC PTP 54200 Model Number 5440BH 5440BHUS 5441BH 5441BHUS 5440BHC 5440BHCUS 5441BHC
DES AES DES or AES DES DES AES AES DES DES AES
2.6.4 2.6.4 Specs in Section 2.6.3 2.6.3 2.6.3 2.6.3 2.6.4 2.6.4 2.6.4
Picture
CMM Type
CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply
Page 20 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
5.4 GHz OFDM Connectorized BH US Model 5.4 GHz OFDM Backhaul (BH) Description 5.4 GHz OFDM BH 10 Mbps
Picture
CMM Type
CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply CMMmicro or CMM4 w/30 VDC supply
2.6.6
5480BH20
DES
2.6.6
5.4 GHz OFDM BH Uncapped 5.4 GHz OFDM BH 10 Mbps 5.4 GHz OFDM BH 20 Mbps 5.4 GHz OFDM BH Uncapped
Table 5 shows the Cambium PMP 400 and PTP 200 Series (4.9 GHz OFDM) AP, SM and BH models. Table 5: 4.9GHz OFDM - PMP 400 and PTP 200 Model Number Descriptions CSM 49400 Model Number 4940SM 4941SM 4940SMC 4941SMC CAP 49400 Model Number 4.9 GHz OFDM Subscriber Module (SM) Description 4.9 GHz OFDM SM 4.9 GHz OFDM SM 4.9 GHz OFDM Connectorized SM 4.9 GHz OFDM Connectorized SM 4.9 GHz OFDM Access Point (AP) Module Description Power 56 VDC Supply Type Specs in Section 2.6.3 2.6.3 2.6.4 Refer to Table 7 for Models Power 56 VDC CMM Type 2.6.4 Specs in Section
Encryption
Picture
Encryption
Picture
4940AP
DES
Appendi x
4941AP
AES
Appendi x
Page 21 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
4940APC
4.9 GHz OFDM Connectorized AP No antenna 4.9 GHz OFDM Connectorized AP No antenna 4.9 GHz OFDM Backhaul (BH) Description
DES
Requires CMM4 w/56 VDC supply Requires CMM4 w/56 VDC supply Power 56 VDC CMM Type Wall type 56VDC supply or CMM4 w/56 VDC supply Wall type 56VDC supply or CMM4 w/56 VDC supply Wall type 56VDC supply or CMM4 w/56 VDC supply Wall type 56VDC supply or CMM4 w/56 VDC supply
2.6.4
AES
Encryption
Picture
DES
4941BH
AES
2.6.3
4940BHC
4.9 GHz OFDM Connectorized BH No antenna 4.9 GHz OFDM Connectorized BH No antenna
DES
2.6.4
4941BHC
AES
2.6.4
A Cluster Management Module (CMM4) provides GPS synchronization and power to the PMP 400/430 and PTP 200/230 series of products: Table 6 details the power requirements of the APs and BHs. Table 6: CMM4 56VDC and 30 VDC Operation Frequency PMP Series Access Point (AP) PMP 430 Series CAP 58430 PTP 230 Series PTP 58230 5.4 GHz PMP 400 Series CAP 54400 PTP 200 Series PTP 54200 PTP 230 Series PTP 54230 PTP 230 Series Backhaul (BH) Canopy Custom Power over Ethernet (PoE) 56 VDC - power on pins 7 and 8 and return on pins 4 and 5 30 VDC - power on pins 7 and 8 and return on pins 4 and 5 30 VDC - power on pins 7 and 8 and return on pins 4 and 5
5.8 GHz
PMP 430 Series CAP 54430 4.9 GHz PMP 400 Series CAP 49400 PTP 200 Series PTP 49200
56 VDC - power on pins 7 and 8 and return on pins 4 and 5 56 VDC - Power on pins 5 & 8, return on pins 4 & 7
The CMM4 can be configured with either or both a 56VDC and a 30VDC external power supply as shown in Figure 10 and Figure 11. The CMM4 must be used for 56 VDC operations which are required for the PMP 430 5.4 and 5.8-GHz AP, and PMP 400 4.9-GHz AP. The CMMmicro only supports 30 VDC operations.
Page 22 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Shown in Figure 13 is a CMM4 with labels for the various parts. When using both a 56 VDC and 30 VDC power supply, it is necessary to install a resistor in the 30 VDC terminal blocks. Refer to instructions included with the CMM4. When planning CMM deployment, consider using both available input terminal blocks for power supply redundancy. For details on configuring the CMM4, refer to the CMM4 User Guide which is available from the Cambium support web site. http://www.cambiumnetworks.com/support.
Figure 13: CMM4 - 56 VDC and 30 VDC terminal blocks A Cluster Management Module (CMMmicro) provides GPS synchronization and 30 VDC power to the: 5.4-GHz PMP 400 Series - CAP 54400 uses 30 VDC 5.4-GHz PTP 200 Series - PTP 54200 uses 30 VDC 5.4-GHz and 5.8-GHz PTP 230 Series PTP 54230/PTP 58230 use 30 VDC
Page 23 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
A 600SSD surge suppressor provides over-voltage and over-current protection to APs, SMs, and BHs in various configurations. The diagram in Figure 14 illustrates the use of the 600SS surge suppressor with the PMP 400/430 AP and SM.
Page 24 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table 7 lists various ancillary equipment and model numbers. Table 7: Ancillary Equipment and Model Numbers Name Model or Part Number Typically use with C C P A S T P M P 5 x 4 3 0 Cluster Management Module micro (CMMmicro 30 VDC power supply) Controller and 8-port embedded switch Outdoor enclosure for controller and switch (but not power supply) 30 VDC power supply included with two models (with 10 ft (3m) DC cable) GPS antenna and mounting bracket 1070CK (with N. American AC cord for power supply) 1070CK-02 (no AC cord) 1070CK-03 (no power supply) X X 5 x 4 3 0 5 x 2 3 0 C C P A S T P M P 5 4 4 0 0 5 4 4 0 0 5 4 2 0 0 C C P A S T P M P 4 9 4 0 0 4 9 4 0 0 4 9 2 0 0
X ACPS120WA (with N. American AC cord for power supply) APCS120W-02A (no AC cord)
PMP 400/430 5.8 & 5.4 GHz SM 29.5 VDC power supply (also for isolated 5.4GHz AP or BH)
Includes 6 ft (2m) DC cord No AC cord needed (plugs directly into AC receptacle) Canopy-proprietary PoE (differs from IEEE 803.3af)
ACPSSW-09B (US, UK, Euro clips) ACPSSW-13B (N. America) ACPSSW-10C (Argentina) ACPWWS-11C (China) ACPSSW-12A (Australia) ACPSSW-14A (Brazil) ACPSSW-20A (Infrastructure Grade, US, UK, EU clips) ACPSSW-21A (Infrastructure Grade, C8 clip to allow AC cord)
Page 25 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Name
Outdoor enclosure for controller and switch (but not power supply) GPS antenna and mounting bracket included No power supply or GPS cables included 1090CK Power supply is not included Order 56 VDC and/or 30 VDC power supply
Cluster Management Module (CMM4) Controller ONLY Without EtherWAN switch Outdoor enclosure for controller (but not power supply) GPS antenna and mounting bracket Rackmount Cluster Management Module (CMM4) Controller ONLY Without EtherWAN switch Designed for 19 rack mounting GPS antenna and mounting bracket 1092 Power supply is not included Order 56 VDC and/or 30 VDC power supply X X X X X 1091 Power supply is not included Order 56 VDC and/or 30 VDC power supply
56 VDC power supply for CMM4 Does not include DC cable or AC line cord Procure locally SGPN4076 PMP 400 4.9GHz SM 56 VDC power supply (also for standalone use with PMP 430 5.4 and 5.8 GHz AP, PMP 400 4.9 GHz AP or PTP 200 4.9 GHz BH) X X X
ACPSSW-15A (US, UK, and EU clips) ACPSSW-16A (C8 clip to allow AC cord)
Page 26 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Name
4.9 GHz SM 56 VDC power supply AC cords (also for standalone use with PMP 430 5.4 and 5.8 GHz AP, PMP 400 4.9 GHz AP or PTP 200 5.4 and 4.9 GHz BH)
SGKN4427A (US/Canada/Mexico) SGKN4426A (Europe) SGKN4425A (Australia) SGKN4424A (China-Mainland) SGKN4423A (Japan) SGKN4422A (Korea) SGKN4421A (United Kingdom/Singapore) SGKN4420A (India/Pakistan/South Africa) SGKN4419A (Argentina)
Surge suppressor (for CMM) 200SS Surge suppressor pole-mount kit Refer to Figure 17 on page 31 SGHN5169A X X X X X X X X X
SMMB1A
SMMB2A
Page 27 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Name
Universal GPS (UGPS) Provides network synchronization for smaller networks where CMM may not be cost effective. The UGPS provides synchronization for one or two modules so that even remote areas at the edge of the network can operate with synchronization for improved performance.
Page 28 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Figure 15: LOS, nLOS, and NLOS Whereas multi-pathing degrades a link in some technologies (FSK, for example), OFDM can often use multipathing to an advantage to overcome nLOS, especially in cases where the Fresnel zone is only partially blocked by buildings, urban canyons, or foliage. OFDM tends to help especially when obstacles are near the middle of the link, and less so when the obstacles are very near the SM, AP, or BH. However, attenuation through walls and trees is substantial for any use of the 5.8 GHz, 5.4 GHz or 4.9 GHz frequency bands. Even with OFDM, these products should not be expected to penetrate walls or extensive trees and foliage.
Applications
Applications for the PMP 400/PTP 200 (5.4-GHz) and PMP 430/PTP 230 (5.4 & 5.8-GHz) Series include: High throughput enterprise applications nLOS video surveillance in metro areas Extend networks into urban areas Extend networks into areas with foliage Applications for the PMP 49400 (4.9-GHz) and PTP 49200 Series systems include: High throughput licensed network for government applications Municipal network - nLOS video surveillance in metro areas Disaster relief network Data service network - extend licensed networks into areas with foliage
Page 29 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
The GUI (Graphical User Interface) is almost identical to Canopys FSK products, with a few additions to support OFDM-specific features. Network features like High Priority using DiffServ, MIR, CIR, NAT, DHCP and VLAN are available for the PMP 400/430 and PTP 200/230 Series OFDM radios, and are configured in the same way as they are for the PMP 100 Series and PTP 100 Series radios. In the 5.4 and 5.8-GHz band, DFS (Dynamic Frequency Selection) is provided for regulatory compliant operation, and is activated (if required per regulatory rules) using the Region Code feature. Two alternate frequencies can be configured to provide service in the unlikely case a module detects radar and triggers DFS, the same as standard Canopy. External Antenna Gain may need to be configured consistent with any antennas used, to avoid making the system overly sensitive to radar detection. Whitening, a technique used to avoid self-interference on Canopy FSK radios, is not offered as an option on the PMP 400/430 and PTP 200/230 Series radios, as whitening is not a technology applicable to an OFDM signal.
IMPORTANT!
When working on sites with both power systems, use care not to wrongly mix power supplies and radios as the two power systems use different pinouts as well as different voltages.
On sites with a mix of 30 VDC and 56 VDC radios (up to the limit of 8 radios supported by one CMM4), a CMM4 connected to both a 30 VDC power supply and a 56 VDC power supply can be used. Due to the full metallic connection to the tower or support structure through the APs antenna or a connectorized BHs antenna, grounding the AP or BH and installing a 600SS surge suppressor within 3 ft (1 m) of the AP or BH (see Figure 14) is strongly recommended to suppress over voltages and over currents, such as those caused by near-miss lightning. APs and BHs provide a grounding lug, as shown in Figure 16, for grounding to the tower or support structure.
Page 30 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Figure 16: AP Grounding Lug A pole mount kit (model no. SGHN5169A) is available for the 600SS. The pole mount kit, shown in Figure 17, provides a grounding point on one of its U-bolts that can be used for terminating ground straps from both the 600SS and the AP.
Administration Systems
Cambium Networks Wireless Manager v3.0 SP 3 is recommended for managing PMP 400/430 and PTP 200/230 Series products with Release 11.2. Cambiums Wireless Manager v3.0 SP 3 is available for download at: http://www.cambiumnetworks.com/support under Management Tools.
Page 31 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Wireless Manager is used to manage and monitor Canopy modules. However; the standalone CNUT tool must be used to upgrade radio software. CNUT 3.20.19 (Canopy Network Updater Tool) is the stand-alone software update tool for PMP 400/430 and PTP 200/230 Series products.. CNUT is available at http://www.cambiumnetworks.com/support under Management Tools. PMP 400/430 and PTP 200/230 equipment may also be managed by SNMP queries based on the Canopy MIB (Management Information Base) objects. Release 11.0 adds support for RADIUS (Remote Authentication Dial In User Service) protocol supporting: SM Authentication allows only known SMs onto the network (blocking rogue SMs), and can be configured to ensure SMs are connecting to a known network (preventing SMs from connecting to rogue APs). RADIUS authentication is used for SMs, but not used for APs, BHMs, or BHSs. SM Configuration configures authenticated SMs with MIR (Maximum Information Rate), CIR (Committed Information Rate), High Priority, and VLAN (Virtual LAN) parameters from the RADIUS server when an SM registers to an AP. Centralized AP and SM user name and password management allows AP and SM usernames and access levels (Administrator, Installer, Technician) to be centrally administered in the RADIUS server instead of on each radio and tracks access events (logon/logoff) for each username on the RADIUS server. BHMs and BHSs do not support RADIUS accounting. This accounting does not track and report specific configuration actions performed on radios or pull statistics such as bit counts from the radios. Such functions require an Element Management System (EMS) such as Cambium Wireless Manager. This accounting is not the ability to perform accounting functions on the subscriber/end user/customer account.
Specifications
PMP 430 (5.4 and 5.8-GHz) products are sold in the following formats: SM - Radio with integrated antenna AP - Kitted, connectorized radio (antenna included) AP Connectorized radio (antenna provided by operator) PMP 400 (5.4 and 4.9-GHz) and PTP 200 (5.4 and 4.9-GHz) products are sold in the following formats: SM/BH - Radio with integrated antenna AP/SM/BH - Connectorized radio (antenna provided by operator) AP - Kitted, connectorized radio (antenna included) PTP 230 (5.4 and 5.8-GHz) products are sold in the following format: SM/BH - Radio with integrated antenna
Page 32 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
5.4 GHz
5.4 GHz
N/A
N/A
4.9 GHz
N/A
N/A
SM Auto Transmit Power Control (TPC) with power set by the AP to provide power leveling for close-in SMs
PMP 430 AP/SM: configurable channel bandwidth: 5, 10 or 20MHz PMP 430 AP/SM: configurable cyclic prefix (1/4, 1/8 or 1/16) PMP 430 AP: Max range 1-30 miles for 5 and 10MHz channel bandwidth, 1-24 miles for 20MHz channel bandwidth PMP 400 AP: Max range 1-30 miles PMP 400 AP/SM and PTP 200 BH: channel bandwidth fixed at 10MHz PMP 400 AP/SM: cyclic prefix fixed at 1/4 PTP 200 BH: configurable cyclic prefix (1/4 or 1/8) PTP 230 BH: configurable channel bandwidth: 10 or 20MHz PTP 230 BH: configurable cyclic prefix (1/4, 1/8 or 1/16) PTP 230 BH: Max range 1-30 miles for 10MHz channel bandwidth, 1-24 miles for 20MHz channel bandwidth Under 22 W DC power Environment range of -40C to +55C (-40F to +131F); 0 to 95% relative humidity, noncondensing PMP 400/430 and PTP 200/230 products are available with either DES or AES encryption
Specifications for PMP 430 (5.4 & 5.8-GHz) SM and PTP 230 (5.4 & 5.8-GHz) BH radio with integrated antenna
Radio with an integrated, internal vertically polarized antenna 1 lb, 11.75 x 3.4 x 3.4 in (hwd) or ~.45 kg, 29.9 x 8.6 x 8.6 cm (hwd) PMP 430 Configurable channel bandwidth: 5, 10 or 20MHz PTP 230 Configurable channel bandwidth: 10 or 20MHz Configurable cyclic prefix: 1/4, 1/8 or 1/16 10 dBi patch antenna - 55 x 55 and 3 dB beam width
Page 33 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Optional LENS mounts directly to SM or BH No additional mounting hardware required o o o o o adds 6 dBi to 10 dB internal patch antenna which can increase range narrows beam width by 3x (from 55 to 18) which can reduce interference caused by multi-path reflections LENS part number: AN500A adds 15 dBi to 10 dB internal patch antenna which can increase range narrows beam width (from 55 to 6) which can reduce interference caused by multi-path reflections
Specifications for PMP 400 (4.9 & 5.4-GHz) AP/SM and PTP 200 (4.9 & 5.4-GHz) BH radio with integrated antenna
Radio with an integrated, internal vertically polarized antenna 10MHz channel bandwidth 1/4 Cyclic Prefix
Page 34 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
15.5 elevation x 17.5 azimuth -- 3 dB beam 17 dBi gain for antenna at 5.4 GHz. 17 dBi antenna gain plus 10 dBm transmit power gives the regulatory maximum of 27 dBm EIRP. 17 dBi gain for antenna at 4.9 GHz. 17 dBi antenna gain plus 18 dBm transmit power gives 35 dBm EIRP. 2.8 lb, 13.25 x 8.25 x 4.38 in (hwd) or ~1.3 kg, 33.7 x 21 x 11.13 cm (hwd)
Figure 20: PMP 400 and PTP 200 radio with integrated antenna
Page 35 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
5.8 GHz - 18 dBi gain for antenna. 18 dBi antenna gain minus 1 dB cable loss plus: 19 dBm tx power gives the U.S. regulatory max 36 dBm EIRP (5, 10 or 20 MHz Channel) 13 dBm tx power gives the Europe regulatory max 30 dBm EIRP. (5MHz Channel) 16 dBm tx power gives the Europe regulatory max 33 dBm EIRP. (10MHz Channel) 19 dBm tx power gives the Europe regulatory max 36 dBm EIRP. (20MHz Channel) 5.4 GHz - 18 dBi gain for antenna. 18 dBi antenna gain minus 1 dB cable loss plus: 7 dBm tx power gives the U.S./Europe regulatory max 24 dBm EIRP. (5MHz Channel) 10 dBm tx power gives the U.S./Europe regulatory max 27 dBm EIRP. (10MHz Channel) 13 dBm tx power gives the U.S./Europe regulatory max 30 dBm EIRP. (20MHz Channel) 4.9 GHz - 17 dBi gain for antenna. 17 dBi antenna gain plus 18 dBm tx power gives 35 dBm EIRP. 13 lb, 28 x 8.25 x 11 in (hwd) or ~6 kg, 71 x 21 x 28 cm (hwd)
Page 36 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Performance
Table 8 shows performance details for PMP 400/430 and PTP 200/230 series. Round trip latency is 5-7 msec for all platforms. Table 8: Performance Details Product PMP 58430 5.8 GHz OFDM and PMP 54430 5.4-GHz OFDM Parameter 1X Modulation 5.8-GHz Max. LOS Range with Integrated SM antenna with LENS that adds 6 dB to SM Range with Reflector Dish that adds 15 dB to SM Range 5.4-GHz Max. LOS Range with Integrated SM antenna with LENS that adds 6 dB to SM Range with Reflector Dish that adds 15 dB to SM Range 5.4 and 5.8-GHz Max. Aggregate Throughput with 1/16 Cyclic Prefix 5.4 and 5.8-GHz Nominal Receive Sensitivity (including FEC) PTP 58230 5.8 GHz OFDM and PTP 54230 5.4-GHz OFDM Modulation 5.8-GHz Max. LOS Range with Integrated BH antenna with LENS that adds 6 dB to BHRange with Reflector Dish that adds 15 dB to BH Range 5.4-GHz Max. LOS Range with Integrated BH antenna with LENS that adds 6 dB to BH Range with Reflector Dish that adds 15 dB to BH Range 5.4 and 5.8-GHz Max. Aggregate 10 MHz Channel: (up+down) 5MHz Channel: (up+down) 10 MHz Channel: (up+down) 20 MHz Channel: (up+down) 5MHz Channel 10MHz Channel 20MHz Channel QPSK 6.4 miles / 10.24 km 13 miles / 20.8 km 30 miles / 48 km 3.4 miles / 5.44 km 6.8 miles / 10.88 km 7.6 miles / 12.16 km 3.5 Mbps 7.5 Mbps 16.5 Mbps -93 dBm -90 dBm -87 dBm QPSK 5 miles / 8 km 20 miles / 32 km 60 miles / 96 km 5 miles / 8 km 11.5 miles / 18.5 km 30 miles / 48 km 8 Mpbs Performance Details 2X 3X 16 QAM 5 miles / 8 km 10 miles / 16 km 29 miles / 46.4 km 2.7 miles / 4.32 km 5.4 miles / 8.64 km 6 miles / 9.6 km 7 Mbps 15 Mbps 32 Mbps -86 dBm -83 dBm -80 dBm 16 QAM 2.2 miles / 3.6 km 9 miles / 14.5 km 28 miles / 45 km 2.2 miles / 3.6 km 5 miles / 8 km 14 miles / 22 km 16.5 Mbps 64 QAM 2.3 miles / 3.68 km 4.5 miles / 7.2 km 13 miles / 20.8 km 1.2 miles / 1.92 km 2.4 miles / 3.84 km 2.7 miles / 4.32 km 10.5 Mbps 22.5 Mbps 45+ Mbps -79 dBm -76 dBm -73 dBm 64 QAM 1 mile / 1.6 km 4 miles / 6.5 km 12 miles / 19 km 1 mile / 1.6 km 2.3 miles / 3.7 km 6.2 miles / 10 km 24.5 Mbps
Page 37 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Throughput with 1/16 Cyclic Prefix 5.4 and 5.8-GHz Nominal Receive Sensitivity (including FEC) PMP 54400 PTP 54200 5.4 GHz OFDM Modulation
17 Mbps
34 Mbps
50 Mbps
-76 dBm -73 dBm 64 QAM 1.4 miles/ 2.25 km PMP: 20.3 Mbps PTP: 21 Mbps -70 dBm 64 QAM 1.4 miles / 2.25 km 20.3 Mbps -70 dBm
Maximum LOS Range with integrated SM antenna Note: LENS and Reflector cannot be used. 10 MHz Channel: (up+down) Max. Aggregate Throughput with 1/4 cyclic prefix
7.5 Mbps
14 Mbps
Nominal Receive Sensitivity (including FEC) PMP 49400 PTP 49200 4.9 GHz OFDM Modulation Maximum LOS Range with integrated SM antenna Note: LENS and Reflector cannot be used. 10 MHz Channel: (up+down) Max. Aggregate Throughput with 1/4 cyclic prefix Nominal Receive Sensitivity (including FEC)
Note: All ranges based on 36dBm EIRP limit @ 5.8GHz, and 30dBm EIRP limit @ 5.4GHz (in 20MHz channels)
Page 38 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Chapter 3: Planning
PMP 400 and PTP 200 Series systems use 10 MHz channel bandwidth configurable on 5 MHz channel centers while the PMP 430 Series is configurable with a 5, 10 or 20 MHz channel bandwidth and the PTP 230 Series is configurable with a 10 or 20 MHz channel bandwidth. When a PMP 430 is configured with 5 MHz channel bandwidth, the radio is configurable on 2.5 MHz center channels and is configurable on 5 MHz center channels when it is configured for either 10 or 20 MHz channel bandwidth. This channel size, along with some different characteristics due to the use OFDM carrier technology and QPSK, 16 QAM, or 64 QAM modulations, supports somewhat different channel planning than for standard Canopy. (For reference, PMP 100 Series uses 20 MHz channels configurable on 5 MHz centers, single carrier technology, and 2-level and 4-level FSK modulation.)
5MHz
United States, Canada, Australia, Brazil and Russia Europe and Other India United States, Canada, Australia, Brazil and Russia Europe and Other India United States, Canada, Australia, Brazil and Russia Europe and Other India
59 19 24
30 10 12
10MHz
29 9 22
15 5 6
20MHz
27 7 22
7 2 6
Page 39 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
(For reference, standard Canopy uses 2-channel re-use with clusters of 6 APs on a tower with channel center spacing of either 25 MHz for Advantage APs or 20 MHz for non-Advantage APs. This is ABCABC channel planning, with 5 MHz guard band between the 20 MHz channels for Advantage APs and no guard band needed for non-Advantage.) Available 5.4 GHz channel center frequencies for each region are shown in Table 10. These vary by region due to different band edge RF specifications (for example, between Canada/US and Europe) requirements in US, Canada, Europe and Australia to not impinge on the frequencies between 5600 and 5650 MHz, which are frequencies on which some weather radar operate Table 10: 5.4 GHz Channel Center Frequencies, by Region Channel Bandwidth Region(s) Range of Center Frequencies Available (MHz) 5475 5597.5 and 5652.5 5715 5472.5 5597.5 and 5652.5 5717.5 5475 5715 5MHz 36 18 Center Channel Spacing 2.5MHz # of center channels 76 # of nonoverlapping channels 38
United States, Canada and Australia 5MHz Europe Brazil, India, Russia and Other United States, Canada and Australia 10MHz Europe Brazil, India, Russia and Other United States, Canada and Australia 20MHz Europe Brazil, India, Russia and Other 20MHz FSK (for comparison) United States, Canada, Europe and Australia
2.5MHz 2.5MHz
78 97
40 49
5480 5595 and 5655 5710 5475 5595 and 5655 5715 5480 5710
5MHz 5MHz
38 47
20 24
5475 5590 and 5660 5705 5470 5590 and 5660 5710 5475 5705
5MHz
34
5MHz 5MHz
36 47
9 12
28
Page 40 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Available 4.9 GHz channel center frequencies are shown in Table 11. Table 11: 4.9 GHz Channel Center Frequencies Range of Center Frequencies Available (MHz) (on 5 MHz centers within this range, inclusive) 4945 - 4985 Number of center channels 9 Maximum number of non-overlapping channels 5
The best practice for channel planning for APs is to conduct extensive site RF surveys before choosing channels. The SM provides a basic Spectrum Analyzer that can be used for site surveys. For more sophisticated analysis, consider consulting an experienced RF engineer and using a full-featured spectrum analyzer.
Downtilt
The standard AP antenna produces a 3 db beam elevation (up and down) of 5, with near-in null fill that allows good coverage of close-in SMs that otherwise would be affected by the narrow pattern. This is a narrower pattern than operators may be used to with standard Canopys 60 3 dB beam, and may require down tilt on the antenna. The bracket of the standard antenna has provision for measured down tilt. The recommended practice is to use one of the many radio analysis and mapping tools or on-line tools to calculate down tilt based on antenna height above the service area.
Weather Radar
Spectrum between 5600 and 5650 MHz (sometimes called the weather notch) is used by some weather radar and is not allowed for use by regulations in some regions, including US, Canada and, for new equipment, Europe. When the Canopy module is set to either of those regions (configured on the Configuration => General page of the module), it will not allow configuration of the appropriate frequencies, as shown in Table 10. Even in regions where use of the spectrum between 5600 and 5650 MHz is allowed, the best practice is to not use these channels if there are any other usable channels available. Only use the channels in this weather notch after monitoring the spectrum for a week or more using a spectrum analyzer to ascertain the spectrum is clear and there is no weather radar in the area that will cause interference to your Canopy system.
Page 41 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
The effect of this, again similar to standard Canopy, is that at any given instant total throughput depends on Mix of links running at 3X, 2X, and 1X Mix of packet sizes
Spectrum Analyzer
A spectrum analyzer is available on the SMs Tools => Spectrum Analyzer page. The spectrum analyzer is also available on an AP by temporarily converting it to an SM by setting the Device Type to SM on the APs Configuration => General page (any SMs registered to the AP will deregister while the AP is in SM mode). The spectrum analyzer works like the spectrum analyzer in classic FSK SMs. Spectrum analyzer uses include: Showing relative power levels (instantaneous and average) across the band, to aid in selecting channels and performing RF planning. Troubleshooting to finding the frequency, relative power level, and location of interferers by rotating a single SM, or triangulating from multiple SMs in a geographical area. Release 10.2 added a configurable setting on the Tools => Spectrum Analyzer web page to display either instantaneous or averaging for spectrum analyzer results for the PTP 100 BHs and PMP 430 5.8-GHz Series. Release 10.3 added this enhancement for the PMP 400/430 5.4-GHz, PTP 200 BHs and PMP 100 Series. The PMP 430 and PTP 230 Series uses average detector rather than peak detector algorithm which results in ~10 dBm lower readings than PMP 400 Series and FSK which use peak detectors. For example, when measuring power from an OFDM AP transmitting on a given channel the PMP 430 5.8-GHz OFDM SM might show a Receive Power Level of -60 dBm while a PMP 100 5.7-GHz FSK SM spectrum analyzer shows a power level of -53 for that channel.
Page 42 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
In addition, an PMP 430 SM measures power across 5, 10 or 20-MHz channels (PTP 230 measures power across 10 or 20-MHz channels) while an FSK SM measures power across 20-MHz channels, so power measurements are not directly comparable between the two. For both FSK and OFDM, the receivers channel bandwidth has been added to the display. This is important to note as the width of the OFDM channel (5, 10 or 20MHz) affects the bandwidth data of the spectrum analyzer sample. The built-in spectrum analyzer can be very useful as a tool for troubleshooting and RF planning, but doesnt duplicate the accuracy and programmability of a dedicated, high-end spectrum analyzer, which may be needed in some cases.
Collocation of 5.8 GHz OFDM with Standard 5.7 GHz Canopy FSK
When locating 5.8 GHz PMP 430 OFDM APs near 5.7 GHz standard Canopy FSK APs (especially on the same tower, but also in the same geographical area), the following practices should be followed to avoid interference between the two systems: Plan spacing between OFDM and FSK channels to provide 25 MHz center spacing, which gives a 10 MHz guard band between the 10 MHz OFDM channel and the 20 MHz FSK channel. Coordinate Downlink Data %, Range, and Control Slot settings using both the OFDM and the FSK frame calculators The following paragraphs give more details on these recommended practices.
Channel Spacing
Center spacing of 25 MHz between collocated FSK and OFDM APs provides a 10 MHz guard band between the 20 MHz and 10 MHz channels, which has proven useful and needed in field testing. Alternatively, in cases where channel planning is severely restricted and the 10 MHz guard band (25 MHz spacing) is not possible, using vertical separation of 5 feet or more between the OFDM and FSK APs may allow collocation with no guard band (15 MHz spacing) in some deployments.
When collocating only Canopy OFDM APs together, or collocating only Canopy hardware-scheduled FSK APs together, the simple practice of setting the Downlink Data %, Range, and Control Slots the same on all APs ensures they wont interfere with each other. (These parameters are set on the Configuration => Radio page of the AP.) However, due to the different physical layer between Canopy OFDM and Canopy FSK, this doesnt necessarily work when collocating OFDM and FSK together.
Page 43 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
You will need to use frame calculators on both the OFDM and FSK modules, as they are different frame calculators. For the same Downlink Data %, Range, and Control Slots, the frame calculators give different results. Use of the frame calculators is similar to the previous use when collocating PMP 100 FSK softwarescheduled and hardware-scheduled APs.
Collocation of 5.4 GHz OFDM with Standard 5.4 GHz Canopy FSK
When locating 5.4 GHz PMP 400/430 and PTP 200/230 Series OFDM APs near 5.4 GHz standard Canopy FSK APs (especially on the same tower, but also in the same geographical area), the following practices should be followed to avoid interference between the two systems: Plan spacing between OFDM and FSK channels to provide 25 MHz center spacing, which gives a 10 MHz guard band between the 10 MHz OFDM channel and the 20 MHz FSK channel. Coordinate Downlink Data %, Range, and Control Slot settings using both the OFDM and the FSK frame calculators
Channel Spacing
Center spacing of 25 MHz between collocated FSK and OFDM APs provides a 10 MHz guard band between the 20 MHz and 10 MHz channels, which has proven useful and needed in field testing. Alternatively, in cases where channel planning is severely restricted and the 10 MHz guard band (25 MHz spacing) is not possible, using vertical separation of 5 feet or more between the OFDM and FSK APs may allow collocation with no guard band (15 MHz spacing) in some deployments.
2. Use the frame calculators in each module, OFDM and FSK (the frame calculators are different,
Page 44 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Using the Tools => Frame Calculator on an OFDM module, enter the desired Downlink Data %, Range, and Control Slot settings, click Calculate, and observe the Rec SEQ Start value. Using the Tools => Frame Calculator on an FSK module, enter the desired Downlink Data %, Range, and Control Slot settings, click Calculate, and observe the Rec SEQ Start value. Iterate, usually adjusting the FSK Downlink Data % and the OFDM Downlink Data % values by a few percent each time, until the Rec SEQ Start times of all collocated modules are within 300 bit times of each other. Configure the OFDM modules using the resulting OFDM values, and the FSK modules using the resulting FSK values.
The frame calculator page (FSK and OFDM) has been simplified with Release 10.3 to show only information pertinent to co-location. It will now display AP TX end time and AP RX start time which allows the operator to more easily calculate co-location duty cycles.
Page 45 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 46 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Chapter 4: Configuring
Most PMP 400/430 Series and PTP 200/230 Series configuration items are identical or very similar to configuration items in standard FSK Canopy modules. This section discusses those that are new or changed and also remarks on some that remain unchanged.
Figure 25: Dynamic Rate Adapt on AP "Configuration => General" page In most cases an operator is well-served to leave the setting at 1X/2X/3X and let the system automatically and dynamically choose the best rate for each link. Cases when it may be useful to lock down a link to 1X or 2X include: If you are having trouble aiming a link or getting it to register, locking the link down to 2X or 1X may help in some cases. If the link is suspected to be oscillating between operation rates to the detriment of throughput, locking the link down may increase throughput. Usually, even if the link is moving rapidly between operation rates, overall link throughput and sector capacity are highest if the link is left at 3X and the link can choose its own rate dynamically. General link troubleshooting Optimal sector utilization involves having as many links as possible running at 3X. This provides as much capacity as possible for the sector. As an example, you want to limit throughput to an individual subscriber to
Page 47 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
1X rates. This does not mean you should set that link to 1X operation. Use MIR (Maximum Information Rate) settings to cap the SMs bandwidth use, but let the link run at as high an operation rate as the RF environment will allow. This ensures that any transmission uses as little air time as possible, leaving more air time for other SMs.
Radio/ Frequency
Channel Size
Max EIRP
(Tx + Antenna Gain)
Region(s)
United States and Canada 5 MHz Europe and India PMP 430 5.8 GHz OFDM United States and Canada 10 MHz Europe and India 20 MHz PMP 430 5.4 GHz OFDM 5 MHz 10 MHz 20 MHz United States, Canada, Europe and India United States, Canada, Europe, India, Russia, Brazil and Australia
PTP 230 5.4 GHz OFDM PMP 400 PTP 200 5.4 GHz OFDM PMP 400 PTP 200 4.9 GHz OFDM
10 MHz 20 MHz
10 MHz
10 dBm
17 dBm
27 dBm
10 MHz
18 dBm
17 dBm
35 dBm
For the PMP 400 5.4-GHz OFDM to meet 27 dBm EIRP with the connectorized 18 dBi antenna (with 1 dB of cable loss) that comes with the 5440AP or 5441AP, or the integrated 17 dBi antenna that comes with a 5440BH or 5441BH, the maximum setting allowed is 10 dBm (the default) since 27-17=10.
Page 48 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
If a connectorized AP or BHM has been purchased and the operator has provided the antenna, the Transmitter Output Power must be configured based on that antenna and consistent with local or regional regulations. For example, if a 5440APC is being used with a 15 dBi antenna, then the maximum setting allowed to meet 27 dBm EIRP is the full 12 dBm of which the radio is capable.
IMPORTANT!
It is the responsibility of the operator and professional installer to ensure Transmitter Output Power is set within regulatory limits for their country or region. These must be set or confirmed on initial configuration and after a module is reset to factory defaults, and should be confirmed after the software on a module is upgraded.
In most cases the operator will want to set the APs Transmitter Output Power to the maximum allowed so as to have the greatest overall range and the greatest range for 3X operation. It may be useful to reduce Transmitter Output Power when Canopy systems are located close together, with good coverage given because of their proximity and full power isnt needed, or in cases where an operator is trying to reduce interference from the Canopy system to other systems. Each SMs Transmitter Output Power is automatically set by the AP. The AP monitors the received power from each SM, and adjusts each SMs Transmitter Output Power so that the received power at the AP from that SM is not greater than -60 dBm. In addition, for 5.4-GHz SMs, the AP sets the SMs Transmitter output power so the SMs EIRP will be within regulatory requirements. PMP 400/430 Series networks use Auto-TPC because OFDM technology is more sensitive to large differences in power levels from SMs operating at various distances from the AP than the single carrier technology used in Canopy FSK. PTP 200 Series bridges do not use Auto-TPC the operator sets Transmitter Output Power on the Configuration => Radio page of both the BHM and the BHS. PMP 400/430 and PTP 200/230 Series modules display the typical Canopy Receive Power Level as shown in Figure 26. Due to the different modulation technique no jitter is calculated or displayed.
Page 49 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Figure 27: Max Range & Downlink Data on AP "Configuration => Radio" page. Suggested Control Slot settings as a function of number of SMs in the sector are shown in Table 13. Generally all APs in a cluster should use the same number of control slots so as to keep the frame structures, and thereby the send and receive timing, the same.
Page 50 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table 13: PMP 400/430 AP Control Slot Settings Number of SMs that Register to the AP 1 to 10 11 to 50 51 to 150 151 to 200 Suggested Number of Control Slots 1 or 2 4 6 8
1
Note 1: Any OFDM sector with the Hi Priority Channel enabled on any SM should be configured with at least 1 Control Slot on the AP. In some cases operators may find that sectors with high levels of small packet requests, such as might be seen in a sector handling several VoIP streams, benefit overall from slightly higher Control Slot settings. If different sectors require different numbers of Control Slots, the operator should use the Frame Calculator to find a combination of settings that put Rec SEQ Start times within 300 bit times. See section 0 on page 44 for details. Control Slots are reserved for SMs bandwidth requests and never handle data. A higher number of control slots gives higher probability that an SMs bandwidth request will be heard when the system is heavily loaded, but with the tradeoff that sector capacity is reduced by about 100 kbps for each Control Slot configured, so there will be less capacity to handle the request. Uplink Data Slots are used first for data. If they are the not needed for data in a given frame the data slot can be used by the SMs for bandwidth requests. This allows SMs in sectors with zero control slots configured to still make bandwidth requests using unused data slots. Downlink Data %, Range, and Control Slots should be set consistent with the results of any collocation planning done using OFDM and FSK frame calculators in section 0 on page 44. The BHM performs its own ranging and so no range need be set for it. BHMs do not have settings for control slots, as there is no bandwidth request contention on the one-to-one link.
DFS and Regulatory Parameters for 5.8 & 5.4 GHz Radios
Dynamic Frequency Selection (DFS) is a requirement in several countries and regions for 5 GHz unlicensed systems to detect radar systems and avoid co-channel operation. DFS and other regulatory requirements drive the settings for the following parameters, as discussed in this section: Region Code Primary Frequency Alternate 1 and Alternate 2 Frequencies External Antenna Gain On the AP/BHM, the Home => DFS Status page shows current DFS status of all three frequencies and a DFS log of past DFS events. Unlike standard Canopy, the PMP 400/430 and PTP 200/230 Series AP, SM, and BH do not offer Whitening, as the OFDM technology obviates the need for it.
Page 51 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Region Code
AP/BHM FCC/IC DFS No effect FCC/IC DFS No effect ETSI DFS ETSI DFS
4 5 3 3
United States 5.8 GHz 5.4 GHz Canada 5.8 GHz 5.4 GHz Europe 5.8 GHz
Page 52 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
5.4 GHz Brazil 5.8 GHz 5.4 GHz Australia 5.8 GHz 5.4 GHz Russia 5.8 GHz 5.4 GHz India 5.8 GHz 5.4 GHz Other 5.8 GHz
1.
ETSI DFS No effect FCC/IC DFS No effect No effect No effect No effect No effect No effect No effect
No effect No effect No effect No effect No effect No effect No effect No effect No effect No effect
No No Yes No No No No No No No
2. 3. 4.
In all cases set the Region Code to the region you are in and the equipment will provide DFS consistent with that regions regulations. For countries or regions not listed, use a Region Code that provides DFS functionality and channels consistent with your countrys regulatory requirements. In some countries and regions, 5600 MHz to 5650 MHz is notched out to meet requirements to not transmit in weather radar frequencies. FCC/IC indicates compliance with FCC Report and Order 03-287 and Industry Canada requirements. ETSI DFS indicates compliance with ETSI EN 301 893 v1.4.1
Page 53 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
BHSs would not be expected to connect to a different BHM, as backhaul links should be configured using color codes and authentication to ensure a BHS only connects with its intended BHM. To simplify operation and ensure compliance, an SM/BHS takes on the DFS type of the AP/BHM to which it registers. For example, when an SM in Europe registers to an AP with t he Region Code set to Europe, that SM will use ETSI DFS, no matter what its Region Code is set to, even if its Region Code is set to None. Note, the operator should still configure the Region Code in the SM correctly, as future releases may use the Region Code for additional region-specific options. For all modules running DFS, the module displays its DFS state on its Home => General Status page as one of the following:
Normal Transmit Radar Detected Stop Transmitting for n minutes, where n counts
down from 30 to 1.
Idle, only for SM/BHS, indicates module is scanning, but has not detected a beacon
from an AP/BHM. Once it detects beacon, the SM/BHS begins a Channel Availability Check on that frequency. Regulatory Note: A PMP 430 Series AP with a Region Code set to United States will not be configurable to another Region Code by installers or end users. This is in response to FCC KDB 594280 and ensures that end users and professional installers will not have access to settings which could allow a radio to be configured to operate in a manner other than that which was specified in the FCC equipment authorization grant. Within the United States and its territories the PMP 430 region code is pre-configured to United States and not selectable in the Configuration => General web page. Radios sold in regions outside of the United States and its territories are required to set the Region Code to the region in which it is used.
IMPORTANT!
Operators under regulatory requirements for DFS must ensure the new Canopy parameter Region Code is set correctly. This applies to initial configuration, after a module is reset to factory defaults, or after a module is upgraded.
Page 54 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
IMPORTANT!
On APs or BHMs received from the factory, with Region Code set to None, the operator must set the Region Code before the module will transmit. The same is true of APs and BHMs which have been reset to factory defaults.
Figure 29: Region Code on AP Configuration => General page An SM/BHS has both a configurable Region Code and, once it registers to an AP or BHM, an active Regional Code. After an SM/BHS registers to an AP/BHM, it uses the region code of the AP/BHM to determine its DFS behavior and displays the AP/BHMs region code on its Home => General Status page . The two Region Codes on an SM/BHS should be the same in normal operation. However, they will not be the same if, for example, an SM configured with a Region Code of None has registered to an AP with a Region Code of Europe. The AP or BHM always operates under its manually configured Region Code (the one on the Configuration => General page), and so does not show a Region Code on its Home => General Status page. Under normal operations, APs and BHMs operating with DFS (see Table 14) will experience an additional minute after power-up or reboot before they will register any SMs or BHSs. SMs and BHSs operating with DFS (see Table 14) will experience an additional minute after they reboot before they will register to an AP or BHM. It takes two reboots to set the parameters described below on a module starting from factory defaults. Set the Region Code as described above, Save Changes, and Reboot. If the module then invokes DFS (based on the region code and frequency band as shown in Table 14), the Radio Frequency Carriers and External Antenna Gain parameters will be displayed. Set them as described below, Save Changes, and Reboot again.
IMPORTANT!
Set the Region Code, Save Changes, and Reboot to see the context-sensitive DFS parameters. Unlike with many context-sensitive parameters, these do not appear in the GUI with only a Save Changes.
Page 55 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 56 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
The range is 0 to 35 dB. A 5.4-GHz SM or BH with an integrated antenna has an External Gain of 17 dB. The antenna sold with the connectorized 5.4 or 5.8 GHz AP has a gain of 18 dB and cable loss of approximately 1 dB, giving an External Gain of 17 dB. A 4.9 GHz SM or BH with an integrated antenna has an External Gain of 17 dB. The antenna sold with the connectorized 4.9 GHz AP has a gain of 18 dB and cable loss of approximately 1 dB, giving an External Gain of 17 dB. Any radio using DFS will use the External Gain to appropriately adjust sensitivity to radar signals. The use of DFS is determined by the Region Code setting on the Configuration => Home page. The Auto-TPC used by the PMP 400/430 and PTP 230 Series system takes into account the External Gain so as not to exceed national or regional EIRP limits.
IMPORTANT!
Ensure the External Gain is set correctly. Setting it low or high can lead to either a system overly sensitive to DFS events or a system not transmitting at its full legal power.
Page 57 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Cyclic Prefix (Configurable only on PTP 200/230 BH & PMP 430 AP/SM)
OFDM technology uses a cyclic prefix, where a portion of the end of a symbol (slot) is repeated at the beginning of the symbol (slot) to allow multi-pathing to settle before receiving the desired data. A 1/4 cyclic prefix means that for every 4 bits of throughput data transmitted, an additional bit is used, A 1/8 cyclic prefix means that for every 8 bit of throughput data transmitted, an additional bit is used. PMP 400 Series networks use a cyclic prefix of 1/4 that is not configurable by the operator. PMP 430 and PTP 230 Series networks use a default cyclic prefix of 1/4 that is configurable by the operator to 1/8 or 1/16. The Cyclic Prefix is set on the Configuration => Radio page on the AP. Changing the default from 1/4 to 1/8 can increase throughput by ~2 Mbps (assuming 75% duty cycle in PMP 430 networks) in installations with low multipath conditions. It is recommended to test 1/8 or 1/16 cyclic prefix to determine actual performance based on RF conditions. PTP 200 Series modules (OFDM BHs) are settable for either 1/8 or 1/4 cyclic prefix. The use of 1/8 cyclic prefix provides about 11% higher maximum throughput, and is recommended for backhaul operations in most cases. The Cyclic Prefix is set on the Configuration => Radio page of the BHM. The default on a new unit or when the unit is reset to factory defaults is 1/4 Cyclic Prefix. In most deployments, 1/8 or 1/16 Cyclic Prefix will provide a high quality, higher throughput link. In cases with severe multi-pathing or obstructions, 1/4 Cyclic Prefix may give better overall results.
IMPORTANT!
The Cyclic Prefix must be set the same on both the BHM and the BHS. If they dont match, the BHS will not register to the BHM.
During installation use Link Tests to confirm link quality per standard installation and alignment procedures. If a Link Test shows low throughput or efficiency, consider changing the Cyclic Prefix to 1/4 on both the BHM and the BHS along with other standard installation troubleshooting procedures such as re-aiming, off-axis aiming, changing location, raising or lowering the height of the radio, adjusting Transmission Power up or down, or identifying and mitigating sources of interference.
Page 58 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Chapter 5: Installation
WARNING!
Installing a unit usually involves height, electricity, and exposure to RF (Radio Frequency) energy. To avoid personal injury, follow applicable national and local safety regulations along with industry best practices. Also follow the specific guidelines in this document, including Exposure Separation Distances in section Appendix on page 75.
2.
3.
4.
Local practices and choices of installation options will dictate the actual processes. For example, variations on these generalized procedures can be used to install on a building or install multiple APs on a pipe mount before hoisting up a tower for final attachment.
Page 59 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 60 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 61 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 62 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 63 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 64 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
3. Use a 600SS surge suppressor within 3 ft (~1 m) of the AP and ground it to known
good ground (Protective Earth - PE) on the tower or support structure with a 10 AWG ground strap.
4. A pole mount kit is available for mounting the 600SS to the tower or mast. The
mount includes a termination point for the ground strap from the 600SS.
5. Run a 10 AWG ground strap from the ground lug on the AP (see Figure 30) to
known good ground (Protective Earth - PE) to complete the grounding and protection of the AP. The termination point on the 600SS pole mount kit may be used for this.
Figure 30: Ground lug highlighted on AP The PMP 400/430 AP and PTP 200 Series BH have metal-to-metal contact from the tower or support structure, through the antenna, through the coax cable, to the radio. Installing surge suppression at the AP is strongly recommended to provide the best protection from near lightning hits. Install a 600SS surge suppressor within 3 ft (~1 m) of an AP or BH. A pole mount kit for the 600SS is shown in Figure 17 to facilitate installation of the 600SS by the AP or BH.
Page 65 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Up to four 600SS surge suppressors may be mounted in series on an Ethernet link without degrading the link. The equivalent of a 600SS is built into each of the 8 ports on a CMM4 and counts as one of the four. The CMMmicro uses a different protection scheme and does not have the equivalent of a 600SS on each port. As an example, a typical installation might have properly-grounded 600SS units within 3 ft of each AP and additional properly-grounded 600SS units on each Ethernet cable mounted outside at the point of cable entry to a telecommunications hut that contains the CMM4.
Page 66 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Figure 32: Dielectric Grease - Insert Ethernet Cable The PMP 400 SM and PTP 200 BH have a ground/Protective Earth lug, just like the AP. Although not as critical as in the case of the AP (where there is metal-to-metal connectivity through the coax and antenna to ground), the lug can be used to ground the SM or BH for additional protection. In addition, a 600SS can be used within 3 ft (1 m) of the SM or BH to provide additional protection. Especially for a BH, or in cases where the SM is mounted high and is more exposed, or in known difficult areas for lightning, consider using these two techniques to increase the radios resistance to lightning. In all cases where Ethernet cables penetrate a building, home, or telecommunications hut, mount a properlygrounded 600SS outside at the point of Ethernet cable building entry to protect persons and property in the building. PMP 400/430 and PTP 200/230 Series modules do not display a jitter value. Use Receive Power Level for aiming and then use Link Tests to confirm alignment. The Receive Power Level is a relative, not absolute, value. The Receive Power Level on a module is useful during installation to aid in aiming where relative values over a short period of time are of interest. The displayed Receive Power Level is not designed to be highly accurate over time. The displayed Receive Power Level will vary with board-level temperature and may vary from module to module even if the actual received power is not varying. Know the limitations and use caution and judgment for any other use of Receive Power Level. Caution is advised when using Receive Power Level for monitoring a link over time, deciding if the link is within operating margins, deciding if a link is serviceable (link tests give a much better indication), or comparing the link to other links. The alignment headset will play a tone that varies in pitch (received power level), but not volume (jitter), since PMP 400/430 and PTP 200/230 Series modules dont calculate a jitter.
Page 67 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Page 68 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table 15: US FCC IDs and Industry Canada Certification Numbers and Covered Configurations FCC ID Industry Canada Cert Number --Frequencies Module Families 5780APC Antenna Maximum Tx Output Power 19 dBm
ABZ89FT7634
5 MHz channels, centered on 5727.55845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 10 MHz channels, centered on 57305845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 20 MHz channels, centered on 57355840 in 5 MHz increments (within the 5725-5850 MHz ISM band)
17 dBi connectorized PCTEL Model 8514724E01 antenna (60 x 5 -3 dB beam width) with 1 dB connector cable loss
ABZ89FT7635
109W-5790
5 MHz channels, centered on 5727.55845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 10 MHz channels, centered on 57305845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 20 MHz channels, centered on 57355840 in 5 MHz increments (within the 5725-5850 MHz ISM band) 10 MHz channels, centered on 57305845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 20 MHz channels, centered on 57355840 in 5 MHz increments (within the 5725-5850 MHz ISM band)
5790SM
19 dBm
5780 BH 5781 BH
19 dBm
Page 69 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
ABZ89FT7637
109W-5480
10 MHz channels, centered on 54805595 and 5655-5710 MHz in 5 MHz increments (within the 5470-5725 MHz U-NII band with 5600-5650 MHz excluded) 20 MHz channels, centered on 54855590 and 5660-5705 MHz in 5 MHz increments (within the 5470-5725 MHz U-NII band with 5600-5650 MHz excluded)
5480 APC
17 dBi connectorized PCTEL Model 8514724E01 antenna (60 x 5 -3 dB beam width) with 1 dB connector cable loss
10 dBm
13 dBm
ABZ89FT7638
109W-5490
10 MHz channels, centered on 54805595 and 5655-5710 MHz in 5 MHz increments (within the 5470-5725 MHz U-NII band with 5600-5650 MHz excluded) 20 MHz channels, centered on 54855590 and 5660-5705 MHz in 5 MHz increments (within the 5470-5725 MHz U-NII band with 5600-5650 MHz excluded)
17 dBm
19 dBm
---
109W-5780
5 MHz channels, centered on 5727.55845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 10 MHz channels, centered on 57305845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 20 MHz channels, centered on 57355840 in 5 MHz increments (within the 5725-5850 MHz ISM band)
5780APC
17 dBi connectorized PCTEL Model 8514724E01 antenna (60 x 5 -3 dB beam width) with 1 dB connector cable loss
19 dBm
---
109W-5790
5 MHz channels, centered on 5727.55845 in 5 MHz increments (within the 5725-5850 MHz ISM band)
5790SM
19 dBm
Page 70 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
10 MHz channels, centered on 57305845 in 5 MHz increments (within the 5725-5850 MHz ISM band) 20 MHz channels, centered on 57355840 in 5 MHz increments (within the 5725-5850 MHz ISM band) ABZ89FT7629 --10 MHz channels, centered on 54805595 and 5655-5710 MHz in 5 MHz increments (within the 5470-5725 MHz U-NII band)
18 dBi connectorized PCTEL Model 8514724E01 antenna (60 x 5 -3 dB beam width) with 1 dB connector cable loss 17 dBi integrated antenna (15 x 15 -3 dB beam width) 18 dBi connectorized PCTEL Model 8514724E01 antenna (60 x 5 -3 dB beam width) with 1 dB connector cable loss 17 dBi integrated antenna (15 x 15 -3 dB beam width) 18 dBi connectorized PCTEL Model AP 85010066001 antenna (60 x 5 -3 dB beam width) with 1 dB cable loss 17 dBi integrated antenna (15.5 x 17.5 (el x az) -3 dB beam width)
5440 AP
10 dBm
5440 SM 5440 BH
10 dBm
---
109W-5440
10 MHz channels, centered on 54805595 and 5655-5710 MHz in 5 MHz increments (within the 5470-5725 MHz U-NII band with 5600-5650 MHz excluded) 10 MHz channels, centered on 49454985 in 5 MHz increments (within the 4940-4990 MHz public safety licensed band)
5440 AP
10 dBm
5440 SM 5440 BH
10 dBm
ABZ89FT7631
109W-4940
4940 AP
18 dBm
4940 SM 4940 BH
18 dBm
Note 1: To ensure regulatory compliance, including DFS compliance, the professional installer is responsible for: setting the Region Code on the Configuration => General page to the correct region setting the Transmitter Output Power on the Confiiguration => Radio page no higher than listed for a given configuration setting the External Gain on the Configuration => Radio page, if displayed, to the gain of any external device (such as a reflector or lens)
Page 71 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to RSS-210 of Industry Canada. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference by one or more of the following measures: Increase the separation between the affected equipment and the unit; Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to; Consult the dealer and/or experienced radio/TV technician for help. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so its Equivalent Isotropic Radiated Power (EIRP) is not more than that permitted for successful communication. Industry Canada Certification Numbers and the specific configurations covered are listed in Table 15. This device has been designed to operate with the antennas listed in Table 15 and having a maximum gain as shown in Table 15. Antennas not included in Table 15 or having a gain greater than as shown in Table 15 are strictly prohibited from use with this device. Required antenna impedance is 50 ohms. For 4.9-GHz devices: The 4.9-GHz band is a licensed band allocated to public safety services. State and local government entities that provide public safety services are eligible to apply for 4.9 GHz licenses. For additional information, refer to Industry Canada regulations.
Page 72 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
member states. The operator is responsible for obtaining any national licenses required to operate this product and these must be obtained before using the product in any particular country. This equipment is marked to show compliance with the European R&TTE directive 1999/5/EC. The relevant Declaration of Conformity can be found at http://www.cambiumnetworks.com/doc.php.
Equipment Disposal
Waste (Disposal) of Electronic and Electric Equipment Please do not dispose of Electronic and Electric Equipment or Electronic and Electric Accessories with your household waste. In some countries or regions, collection systems have been set up to handle waste of electrical and electronic equipment. In European Union countries, please contact your local equipment supplier representative or service center for information about the waste collection system in your country.
UK Notification
The 5.8 GHz connectorized product has been notified for operation in the UK, and when operated in accordance with instructions for use it is compliant with UK Interface Requirement IR2007. For UK use, installations must conform to the requirements of IR2007 in terms of EIRP spectral density against elevation profile above the local horizon in order to protect Fixed Satellite Services. The frequency range 5795-5815 MHz is assigned to Road Transport & Traffic Telematics (RTTT) in the U.K. and shall not be used by FWA systems in order to protect RTTT devices. UK licensing specifies that radiolocation services shall be protected by a Dynamic Frequency Selection (DFS) mechanism to prevent co-channel operation in the presence of radar signals.
Luxembourg Notification
5.4GHz products can only be used for mobile services.
Greece Notification
The outdoor use of 5470-5725MHz is under license of EETT but is being harmonized according to the th CEPT Decision ECC/DEC/(04) 08, of 9 July. End users are advised to contact the EETT to determine the latest position and obtain any appropriate licenses.
Page 73 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Brazil Notification
Brazil regulatory authorities have not approved these devices for operation in Brazil. Until they are approved, they are not available for sale in Brazil, and the information in this section is provisional and preliminary. For compliant operation in the 5.4 GHz band, the Equivalent Isotropic Radiated Power from the integrated antenna or connectorized anteanna shall not exceed 27 dBm (0.5 W). The operator is responsible for enabling the DFS feature on any Canopy 5.4 GHz radio by setting the Region Code to Brazil, including after the module is reset to factory defaults. Important Note: This equipment operates as a secondary application, so it has no rights against harmful interference, even if generated by similar equipment, and cannot cause harmful interference on systems operating as primary applications.
Logo 1
Logo 2
The Environmental Friendly Use Period (EFUP) is the period (in years) during which the Toxic and Hazardous Substances (T&HS) contained in the Electronic Information Product (EIP) will not leak or mutate causing environmental pollution or bodily injury from the use of the EIP. The EFUP indicated by the Logo 2 label applies to a product and all its parts. Certain field-replaceable parts, such as battery modules, can have a different EFUP and are marked separately. The Disclosure Table (see Table 16) is intended only to communicate compliance with China requirements; it is not intended to communicate compliance with EU RoHS or any other environmental requirements.
Page 74 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Table 16: Disclosure Table (Pb) (Hg) (Cd) (Cr6+) (PBB) (PBDE)
SJ/T11363-2006 SJ/T11363-2006
Section Appendix and Table 18 give details and discussion of the associated calculations.
Page 75 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
Health Canada limits for the general population. See Safety Code 6 on the Health Canada web site at http://www.hc-sc.gc.ca/. ICNIRP (International Commission on Non-Ionizing Radiation Protection) guidelines for the general public. See the ICNIRP web site at http://www.icnirp.de/ and Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields. The applicable power density exposure limits from the documents referenced above are 10 W/m2 for RF energy in the 4.9, 5.4, and 5.7-GHz frequency bands. Peak power density in the far field of a radio frequency point source is calculated as follows:
P G 4 d2
where 2 S = power density in W/m P = RMS transmit power capability of the radio, in W G = total Tx gain as a factor, converted from dB d = distance from point source, in m
P G 4 S
Table 18 shows calculated minimum separation distances d, recommended distances and resulting power compliance margins for each frequency band and antenna combination. Table 18: Calculated Exposure Distances and Power Compliance Margins Frequency Band Antenna Variable P G S d (calculated) 8 cm Recommended Separation Distance 20 cm (8 in) Power Compliance Margin 6.3
Integrated, 10 dBi
10 (10 dB)
50 (17 dB)
6 cm
20 cm (8 in)
10
Integrated, 10 dBi
10 (10 dB)
8 cm
20 cm (8 in)
6.3
40 (16 dB)
14 cm
20 cm (8 in)
Page 76 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
The Recommended Distances are chosen to give significant compliance margin in all cases. They are also chosen so that an OFDM module has the same exposure distance as a Canopy module, to simplify communicating and heeding exposure distances in the field. These are conservative distances: They are along the beam direction (the direction of greatest energy). Exposure to the sides and back of the module will be significantly less. They meet sustained exposure limits for the general population (not just short term occupational exposure limits), with considerable margin. The calculated compliance distance d is overestimated because the far-field equation models the antenna as a point source and neglects the physical dimension of the antenna.
Legal Notices
Software License Terms and Conditions
ONLY OPEN THE PACKAGE, OR USE THE SOFTWARE AND RELATED PRODUCT IF YOU ACCEPT THE TERMS OF THIS LICENSE. BY BREAKING THE SEAL ON THIS DISK KIT / CDROM, OR IF YOU USE THE SOFTWARE OR RELATED PRODUCT, YOU ACCEPT THE TERMS OF THIS LICENSE AGREEMENT. IF YOU DO NOT AGREE TO THESE TERMS, DO NOT USE THE SOFTWARE OR RELATED PRODUCT; INSTEAD, RETURN THE SOFTWARE TO PLACE OF PURCHASE FOR A FULL REFUND. THE FOLLOWING AGREEMENT IS A LEGAL AGREEMENT BETWEEN YOU (EITHER AN INDIVIDUAL OR ENTITY), AND CAMBIUM NETWORKS (FOR ITSELF AND ITS LICENSORS). THE RIGHT TO USE THIS PRODUCT IS LICENSED ONLY ON THE CONDITION THAT YOU AGREE TO THE FOLLOWING TERMS. Now, therefore, in consideration of the promises and mutual obligations contained herein, and for other good and valuable consideration, the receipt and sufficiency of which are hereby mutually acknowledged, you and Cambium agree as follows: Grant of License. Subject to the following terms and conditions, Cambium Networks grants to you a personal, revocable, non-assignable, non-transferable, non-exclusive and limited license to use on a single piece of equipment only one copy of the software contained on this disk (which may have been pre-loaded on the equipment)(Software). You may make two copies of the Software, but only for backup, archival, or disaster recovery purposes. On any copy you make of the Software, you must reproduce and include the copyright and other proprietary rights notice contained on the copy we have furnished you of the Software. Ownership. Cambium Networks (or its supplier) retains all title, ownership and intellectual property rights to the Software and any copies, including translations, compilations, derivative works (including images) partial copies and portions of updated works. The Software is Cambiums (or its supplier's) confidential proprietary information. This Software License Agreement does not convey to you any interest in or to the Software, but only a limited right of use. You agree not to disclose it or make it available to anyone without Cambiums written authorization. You will exercise no less than reasonable care to protect the Software from unauthorized disclosure. You agree not to disassemble, decompile or reverse engineer, or create derivative works of the Software, except and only to the extent that such activity is expressly permitted by applicable law. Termination. This License is effective until terminated. This License will terminate immediately without notice from Cambium or judicial resolution if you fail to comply with any provision of this License. Upon such termination you must destroy the Software, all accompanying written materials and all copies thereof, and the sections entitled Limited Warranty, Limitation of Remedies and Damages, and General will survive any termination. Limited Warranty. Cambium warrants for a period of ninety (90) days from Cambiums or its customers shipment of the Software to you that (i) the disk(s) on which the Software is recorded will be free from defects in materials and workmanship under normal use and (ii) the Software, under normal use, will perform substantially in accordance with Cambiums published specifications for that release level of the Software. The written materials are provided "AS IS" and without warranty of any kind. Cambium's entire liability and your sole and exclusive remedy for any breach of the foregoing limited warranty will be, at Cambium's option, replacement of the disk(s), provision of downloadable patch or replacement code, or
Page 77 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
refund of the unused portion of your bargained for contractual benefit up to the amount paid for this Software License. THIS LIMITED WARRANTY IS THE ONLY WARRANTY PROVIDED BY CAMBIUM, AND CAMBIUM AND ITS LICENSORS EXPRESSLY DISCLAIM ALL OTHER WARRANTIES, EITHER EXPRESS OF IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. CAMBIUM DOES NOT WARRANT THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE, OR THAT DEFECTS IN THE SOFTWARE WILL BE CORRECTED. NO ORAL OR WRITTEN REPRESENTATIONS MADE BY CAMBIUM OR AN AGENT THEREOF SHALL CREATE A WARRANTY OR IN ANY WAY INCREASE THE SCOPE OF THIS WARRANTY. CAMBIUM DOES NOT WARRANT ANY SOFTWARE THAT HAS BEEN OPERATED IN EXCESS OF SPECIFICATIONS, DAMAGED, MISUSED, NEGLECTED, OR IMPROPERLY INSTALLED. BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF IMPLIED WARRANTIES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. Limitation of Remedies and Damages. Regardless of whether any remedy set forth herein fails of its essential purpose, IN NO EVENT SHALL CAMBIUM OR ANY OF THE LICENSORS, DIRECTORS, OFFICERS, EMPLOYEES OR AFFILIATES OF THE FOREGOING BE LIABLE TO YOU FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL OR SIMILAR DAMAGES WHATSOEVER (including, without limitation, damages for loss of business profits, business interruption, loss of business information and the like), whether foreseeable or unforeseeable, arising out of the use or inability to use the Software or accompanying written materials, regardless of the basis of the claim and even if Cambium or a Cambium representative has been advised of the possibility of such damage. Cambium's liability to you for direct damages for any cause whatsoever, regardless of the basis of the form of the action, will be limited to the price paid for the Software that caused the damages. THIS LIMITATION WILL NOT APPLY IN CASE OF PERSONAL INJURY ONLY WHERE AND TO THE EXTENT THAT APPLICABLE LAW REQUIRES SUCH LIABILITY. BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU. Maintenance and Support. Cambium shall not be responsible for maintenance or support of the software. By accepting the license granted under this agreement, you agree that Cambium will be under no obligation to provide any support, maintenance or service in connection with the Software or any application developed by you. Any maintenance and support of the Related Product will be provided under the terms of the agreement for the Related Product. Transfer. In the case of software designed to operate on Cambium equipment, you may not transfer the Software to another party except: (1) if you are an end-user, when you are transferring the Software together with the Cambium equipment on which it operates; or 2) if you are a Cambium licensed distributor, when you are transferring the Software either together with such Cambium equipment or are transferring the Software as a licensed duly paid for upgrade, update, patch, new release, enhancement or replacement of a prior version of the Software. If you are a Cambium licensed distributor, when you are transferring the Software as permitted herein, you agree to transfer the Software with a license agreement having terms and conditions no less restrictive than those contained herein. You may transfer all other Software, not otherwise having an agreed restriction on transfer, to another party. However, all such transfers of Software are strictly subject to the conditions precedent that the other party agrees to accept the terms and conditions of this License, and you destroy any copy of the Software you do not transfer to that party. You may not sublicense or otherwise transfer, rent or lease the Software without our written consent. You may not transfer the Software in violation of any laws, regulations, export controls or economic sanctions imposed by the US Government. Right to Audit. Cambium shall have the right to audit annually, upon reasonable advance notice and during normal business hours, your records and accounts to determine compliance with the terms of this Agreement. Export Controls. You specifically acknowledge that the software may be subject to United States and other country export control laws. You shall comply strictly with all requirements of all applicable export control laws and regulations with respect to all such software and materials. US Government Users. If you are a US Government user, then the Software is provided with "RESTRICTED RIGHTS" as set forth in subparagraphs (c)(1) and (2) of the Commercial Computer Software-Restricted Rights clause at FAR 52 227-19 or subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, as applicable. Disputes. You and Cambium hereby agree that any dispute, controversy or claim, except for any dispute, controversy or claim involving intellectual property, prior to initiation of any formal legal process, will be submitted for non-binding mediation, prior to initiation of any formal legal process. Cost of mediation will be shared equally. Nothing in this Section will prevent either party from resorting to judicial proceedings, if (i)
Page 78 of 79
PMP 400/430 and PTP 200/230 Series Configuration and User Guide
good faith efforts to resolve the dispute under these procedures have been unsuccessful, (ii) the dispute, claim or controversy involves intellectual property, or (iii) interim relief from a court is necessary to prevent serious and irreparable injury to that party or to others. General. Illinois law governs this license. The terms of this license are supplemental to any written agreement executed by both parties regarding this subject and the Software Cambium is to license you under it, and supersedes all previous oral or written communications between us regarding the subject except for such executed agreement. It may not be modified or waived except in writing and signed by an officer or other authorized representative of each party. If any provision is held invalid, all other provisions shall remain valid, unless such invalidity would frustrate the purpose of our agreement. The failure of either party to enforce any rights granted hereunder or to take action against the other party in the event of any breach hereunder shall not be deemed a waiver by that party as to subsequent enforcement of rights or subsequent action in the event of future breaches.
Hardware Warranty in US
Cambium US offers a warranty covering a period of 1 year from the date of purchase by the customer. If a product is found defective during the warranty period, Cambium will repair or replace the product with the same or a similar model, which may be a reconditioned unit, without charge for parts or labor.
Limit of Liability
IN NO EVENT SHALL CAMBIUM BE LIABLE TO YOU OR ANY OTHER PARTY FOR ANY DIRECT, INDIRECT, GENERAL, SPECIAL, INCIDENTAL, CONSEQUENTIAL, EXEMPLARY OR OTHER DAMAGE ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS, OR FROM ANY BREACH OF WARRANTY, EVEN IF CAMBIUM HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you.) IN NO CASE SHALL CAMBIUMS LIABILITY EXCEED THE AMOUNT YOU PAID FOR THE PRODUCT.
Page 79 of 79