Fosroc offers a comprehensive technical support service to specifiers, end users and contractors. It is also able to offer on-site technical assistance, an AutoCAD facility and dedicated specification assistance in locations all over the world. Properties Membrane thickness (+/- 5%) : (ASTM D 751) : Nominal weight : Reinforcement base : Softening point (ASTM D36) : Penetration (ASTM D5) : Flexibility at low temperature (Din 52123) : Tensile strength Longitudinal (UEAtc) : Transverse (UEAtc) : Elongation of membrane Longitudinal (UEAtc) : Transverse (UEAtc) : Tear resistance Longitudinal (ASTM D4073) : Transverse (ASTM D4073) : Lap joint strength Longitudinal (UEAtc) : Transverse (CGSB37-GP56m) : Load Strain Longitudinal (CGSB-37-GP56M): Transverse : Puncture Resistance Static (UEAtc) : Dynamic : Water absorption (ASTM D5147) : W ater vapour transmission (ASTM E96) : Resistance to ageing due to : UV radiation(ASTM G53) Pliability @ 500C for 3 hrs : Proofex 3P - 3mm Proofex 4P - 4mm 3mm - 3.5kg/m 4mm - 4.5kg/m 180g/m 150C 17 - 25 dmm -5C 790 N/5cm 730 N/5cm 65% 69% 180 N 190 N 750 N/5cm 550 N/5cm 41,000 36,000 1:4 1.3 <0.15% <0.50g/m/24h No signs of deterioration after the test No sign of cracking
page 1 of 2
Priming Proofex Torchseal Primer must be applied to the substrate and allowed to dry until it is tack free, prior to the application of the membrane. All surfaces must be re-primed if left for more than 24 hours prior to the application of Proofex Torchseal membranes. Application The membrane is unrolled and placed in the correct position where it is to be torched on later. During each stage, each roll must overlap the next layer by atleast 10cm. The membrane is rolled back without changing the orientation. The rolled membrane is slowly unrolled again, while its surface is lightly heated, transversally, by means of a propane gas torch, thus causing surface melting and subsequent adhesion to the surface. End joints should be made with a minimum of 15cm overlap. Application tools and equipment The tools and equipment required to apply Proofex Torchseal 3P and 4P membrane include a propane gas torch with related gas cylinder, a knife for cutting the membrane to size and a trowel with a rounded tip. Protective gloves and goggles are necessary when using the gas torch.
Estimating
Supply Proofex Torchseal 3P/4P Proofex Torchseal Primer Coverage Proofex Torchseal Primer Storage All products have a shelf life of 12 months if stored in a cool, dry store, away from sources of heat, in the original unopened packing. It should be stored horizontally, not more than one pallet high. : 0.2 - 0.8 lt/m : : 10 m long x 1m wide roll 20 and 200 litre drums
Precautions
Health and safety If Proofex Torchseal Primer is swallowed, do not induce vomiting - drink a glass of water. If contact with eyes occurs, flood with copious amounts of clean water for at least 15 minutes and seek medical advice. If on the skin, remove any contaminated clothing and wash skin thoroughly. For further information, please consult Material Safety Data Sheets for the above products. * Dinotes trademark of Fosroc International Ltd.
Important note : Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard terms and conditions of sale, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that any advice, recommendation specification or information it may give is accurate and correct, it cannot, because it has no direct or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the use of its products whether or not in accordance with any advice, specification, recommendation or information given by it.
telephone ++91 80-23551500 fax ++91 80-23551510 e-mail [email protected]
Regional Offices
Bangalore
Sapthagiri Palace, No. 38 II & III Floor, 12th Cross, CBI Road, Ganganagar North, Bangalore 560 032. Ph:080-23551500 Fax : 080-23551510
Mumbai
1401/1402, 14 Floor, A-WingThe Great Eastern Summit Sector-15, CBD, Belapur Navi Mumbai 400 614 Ph: 022 -43406800-04
Noida
D-166 Sector 10 Noida, UP 201 301 Ph:0120-4270620
Kolkata
304, Jodhpur Park Kolkata 700 068 Ph:033-65343188 Fax: 033-2499-0280
www.fosroc.com
page 2 of 2
INDIA/2011/0855/B