Member - Light Gage Structural Institute
Member - Light Gage Structural Institute
Member - Light Gage Structural Institute
SHEAR CENTER
EAVE STRUT
Xo y
_ X
R=0.1875
ST
R UCT U R
AL
HT G AG E
IN S
T IT U T
LIG
E
#
ES
T . 19 9
Pattern A
B1 50
Pattern D and E
SHEAR CENTER
GAUGE X X R=0.1875 D
d Y
B2
TABLE OF CONTENTS
Commercial / Industrial
General Notes...... 4 Manufacturing & Product Information.. 5 Definitions of Loads & Lap Conditions.... 6 Punching Patterns for Cees & Zees............. 9 Lap Patterns for Cees & Zees....... 11 Punching Patterns for Eave Struts...... 15 C-Section Specifications & Properties........... 19 Z-Section Specifications & Properties........ 20 Eave Struts, Angles & Channels....... 21 Hats & Girts.....22 Light Gage Structural Institute........................ 23 LGSI Framing System Design Handbook. Please Inquire
In a continuing effort to refine and improve products, PROLAMSA reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To insure you have the latest information available, please inquire or visit our Web site at http://www.prolamsa.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions or building designs. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices.
GENERAL NOTES
PROLAMSA offers a complete line of structural shapes, formed using high strength steel, ASTM A-570 (55,000 psi min. yield point), finished with a baked-on red oxide primer finish or G-90 galvanized finish. Substructural components from PROLAMSA are manufactured in Light Gage Structural Institute (LGSI) sections. LGSI sections have been found to have numerous advantages, including greater ease of installation. Consult the LGSI technical manual for proper product application. All standard structural shapes (except eave struts, hats and girts) are roll-formed to ensure a maximum quality finished product. Standard web and flange punching are available upon request. Custom punching is another feature that PROLAMSA provides. Please contact our office for pricing and availability. PROLAMSA produces many open shapes and sizes that can be manufactured to your design specifications.
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
SNOW LOAD The value used for snow load will be specified by your local building codes. Special conditions that will encourage heavier than normal accumulations should be considered, such as multiple gables, abrupt changes in roof elevation, etc. WIND LOAD Wind load is the amount of load that is imposed on a structure as a result of wind in any horizontal direction. The value you use for wind load is determined by local building codes. Wind action on a structure causes forces to be applied on all exposed surfaces. Determining the wind load value for a roof or wall requires the use of coefficients. The sample calculations refer to the coefficients in this table.
SURFACE ROOF WALLS MEMBER TYPE PURLINS GIRTS SYMBOL RCOEF WCOEF
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
To obtain the values for these coefficients, refer to local building codes. Typical values for RCOEF and WCOEF are 1.2 and 1.1 respectively. These apply only to enclosed buildings with a roof slope of less than 10 degrees.
DEAD LOAD Dead load is the weight of the building components that are being supported by the section. COLLATERAL LOAD Collateral load is the weight of additional permanent materials, such as sprinklers, mechanical and electrical systems, partitions and ceiling. Collateral loads do not include dead loads.
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
LOAD COMBINATIONS The value for live load in the sample calculations is the larger of live load and snow load, as defined above. This value is combined with dead load and collateral load in the sample calculations under the heading DEAD + LIVE load. STRUCTURAL MATERIAL SPECIFICATIONS For all Cee, Zee and Eave Strut sections: Fu = 64.7 ksi Fy = 55.0 ksi LAP CONDITIONS
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
Pattern A
Pattern B
Pattern C
NOTES: 1. Common flange punching Pattern D has Pattern A in the web. Common flange punching Pattern E has Pattern B in the web. 2. Punching is not available on 4 or smaller Cees and Zees. 3. All slots are 5/8 x 3/4.
Pattern G
Common End
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
Patterns D and E
Pattern F
NOTES: 1. Common flange punching Pattern D has Pattern A in the web. Common flange punching Pattern E has Pattern B in the web. 2. Punching is not available on 4 or smaller Cees and Zees. 3. All slots are 5/8 x 3/4.
10
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
SIMPLE SPAN
TOTAL LAP
SHORT LAP
TOTAL LAP
LONG LAP
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
11
TOTAL LAP
TOTAL LAP
MAX LAP
12
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
FLANGE BRACE
SUPER LAP
Consult the Light Gage Structural Institute(LGSI) Manual for engineering information.
13
SIMPLE SPAN
TOTAL LAP
SHORT LAP
TOTAL LAP
LONG LAP
14
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
NOTES 1. All slots are 5/8 x 3/4. 2. Eave strut is 14 gauge. 3. Universal eave strut is designed for all roof slopes 1:12 through 4:12.
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
15
16
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
17
18
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
D in.
12 12 10 10 10 10 8 8 8 8 8 8 6 6 4 4
B in.
3.5 3.5 3.5 3.5 2.5 2.5 3.5 3.5 3.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
d in.
0.885 0.800 0.885 0.800 0.885 0.800 0.885 0.800 0.773 0.885 0.800 0.773 0.800 0.773 0.800 0.773
R in.
0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875 0.1875
Area in.
2
wt/ft lb
7.271 5.195 6.542 4.673 5.812 4.152 5.812 4.152 3.321 5.083 3.631 2.905 3.110 2.488 2.589 2.071
Ix 4 in.
43.753 29.370 28.452 19.134 23.311 15.683 16.918 11.410 9.651 13.645 9.209 7.791 4.686 3.971 1.834 1.559
Sx 3 in.
7.292 4.895 5.690 3.827 4.662 3.137 4.229 2.852 2.413 3.411 2.302 1.948 1.562 1.324 0.917 0.780
rx in.
4.572 4.587 3.887 3.904 3.732 3.749 3.180 3.198 3.204 3.054 3.072 3.078 2.368 2.374 1.624 1.631
Iy 4 in.
3.069 2.043 2.909 1.938 1.275 0.852 2.710 1.807 1.523 1.194 0.799 0.674 0.729 0.615 0.630 0.532
Sy 3 in.
1.171 0.773 1.150 0.759 0.682 0.451 1.123 0.741 0.623 0.669 0.442 0.372 0.429 0.361 0.408 0.343
ry in.
1.211 1.210 1.243 1.242 0.873 0.874 1.273 1.273 1.273 0.903 0.905 0.906 0.934 0.935 0.952 0.953
x bar in.
0.879 0.855 0.971 0.947 0.632 0.610 1.086 1.061 1.053 0.715 0.692 0.685 0.802 0.795 0.957 0.949
Ixy 4 in.
1.493 0.941 1.238 0.781 0.854 0.542 0.984 0.621 0.514 0.678 0.431 0.357 0.320 0.265 0.209 0.173
2.093 1.396 1.883 1.256 1.673 1.116 1.673 1.116 0.94 1.463 0.976 0.822 0.836 0.704 0.696 0.586
GAUGE x x
R=0.1875
Xo y
NOTES: Consult the LGSI technical manual for proper product application, design details, and other product information All Cees available in Red Oxide Primer and Galvanized finish. Properties are based on ASTM A570/A607 Grade 55 or 60 having a minimum yield strength of 55 ksi.
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
19
B2 50
SHEAR CENTER
x R=0.1875 d B1 y
GAUGE
NOTES: Consult the LGSI technical manual for proper product application, design details, and other product information. All Zees available in Red Oxide Primer and Galvanized finish. Properties are based on ASTM A57/A607 Grade 55 or 60 having a minimum yield strength of 55 ksi.
20
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
WEIGHT Lb/Ft
4.348 3.478 4.932 3.945
All finishes 5 to 30. Properties are based on ASTM A570/A607 Grade 55 or 60 having a minimum yield strength of 55 ksi.
Angles
NORMAL Size (in) 2 1/2" x 2" 3" x 2" 3" x 3" 4" x 2" 6" x 4"
WEIGHT Lb/Ft
1.172 0.938 1.303 1.042 1.563 1.250 1.563 1.250 2.605 2.084
All finishes 5 to 25. Properties are based on ASTM A570/A607 Grade 55 or 60 having a minimum yield strength of 55 ksi.
Channels
NORMAL Size (in) 4 3/16" x 2" 6 3/16" x 2" GAUGE Min. Thickness
14 ( 0.069" 16 ( 0.056") 12 (0.096") 14 (0.069") 16 ( 0.056") 12 (0.096") 14 (0.069") 16 ( 0.056") 12 (0.096") 14 (0.069") 16 ( 0.056")
WEIGHT Lb/Ft
2.040 1.632 3.585 2.561 2.048 4.314 3.082 2.465 5.044 3.603 2.882
8 3/16" x 2"
10 3/16"" x 2"
All finishes 5 to 25. Properties are based on ASTM A570/A607 Grade 55 or 60 having a minimum yield strength of 55 ksi.
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
21
WEIGHT Lb/Ft
1.278 1.123 0.899 0.705 0.564
LENGTH
20 20 20 20 20
HAT #H1
1 SUB-GIRT #SG1
22
Consult the Light Gage Structural Institute (LGSI) Manual for engineering information.
23
www.prolamsausa.com