FAG Alignment Tools: Top-Laser: Smarty2 Trummy2 Equilign Shim
FAG Alignment Tools: Top-Laser: Smarty2 Trummy2 Equilign Shim
FAG Alignment Tools: Top-Laser: Smarty2 Trummy2 Equilign Shim
Foreword
Higher cost-effectiveness
Correct alignment can help to achieve higher cost-effectiveness. Even machines with very high performance can sometimes still be incapable of fulfilling expectations, for example if they are not adequately aligned. Even minimal deviations can lead to major damage. With the products presented here, Schaeffler assists in the optimum alignment of belts and precise alignment of coupled and non-coupled machine shafts. Alignment is worth performing and gives savings in resources. Precise alignment ensures lower operating and maintenance costs in the long term. In addition, wear is reduced, the lifetime of machinery is increased and energy costs are cut. Products and service for your success reliable, versatile, competent. Even after the purchase of a product, Schaeffler offers lasting solutions relating to mounting and maintenance. With the aid of the diverse portfolio of products and services, operating life and performance capability of production plant can be increased and overall costs can be reduced. In addition, the presence of Schaeffler engineers worldwide guarantees that you receive competent support directly at your location. The portfolio of products and services encompasses not only mounting, lubrication, condition monitoring and rolling bearing reconditioning but also training. All the products and services presented here have been tested in practical use and are certified in accordance with ISO 9001.
Savings
Foreword
Important to know
In the interests of rapid assistance, Schaeffler has brought together valuable knowledge relating to the mounting and dismounting of rolling bearings in the Mounting Toolbox. Videos show what must be observed in order to achieve correct lubrication, mounting and alignment. The Virtual Plant makes it possible to watch the work of fitting personnel at close quarters, Figure 1.
http://mounting-toolbox.schaeffler.com
0001935A
Contents
Page Alignment Product overview.................................................................. 4
Features............................................................................... 5 Belt pulley alignment device FAG Top-Laser SMARTY2....... 5 Belt tension measuring device FAG Top-Laser TRUMMY2... 9 Shaft alignment device FAG Top-Laser EQUILIGN............... 12 Shims FAG Top-Laser SHIM .............................................. 21 Services Product overview.................................................................. 24 Mounting ............................................................................. 25 Lubrication........................................................................... 25 Rolling bearing grease Arcanol ......................................... 26 Condition monitoring ........................................................... 26
Schaeffler Technologies
TPI 182
Product overview
Alignment
Belt pulley alignment device Top-Laser SMARTY2 Belt tension measuring device Top-Laser TRUMMY2
LASER-SMARTY2
LASER-TRUMMY2
LASER-EQUILIGN
00019CE3
LASER-SHIM
TPI 182
Schaeffler Technologies
00019D92
00019C84
00019C83
Alignment
These products assist you in the alignment of shafts and belt pulleys and the checking of belt tension values. The FAG Top-Laser SMARTY2 is a line laser for the alignment of belt pulleys and chain sprockets with a diameter of more than 60 mm. The alignment of belt pulleys and chain sprockets reduces wear and energy losses in tension drives, their bearings and seals. Less heat is generated and the lifetime and reliability of the machines is increased. The features of the line laser are as follows: The parallelism and angular errors of the two pulleys are displayed. Alignment can be carried out on both horizontally and vertically mounted belt pulleys. Alignment is significantly more rapid and more precise than with conventional methods. Alignment can be carried out by one person working alone. The measuring device is attached to the pulleys by magnetism. The target marks are available in an optical and an electronic design, Figure 1. In the case of electronic target marks, the adjustment values are displayed in real time on the digital display. Angular errors are shown in degrees, while the parallelism offset is shown in millimetres. Do not look into the laser beam and do not point the laser beam into the eyes of other people.
Caution
Schaeffler Technologies
TPI 182
000192A8
Alignment
All the parts are supplied in a lined case, Figure 2. Scope of delivery 1 emitter 2 optical target marks, attached by magnetism 1 battery 1 lined case LASER-SMARTY2
Ordering designation
Figure 2 Scope of delivery FAG Top-Laser SMARTY2 Replacement part Ordering designation Accessories Ordering designation 1 optical target mark, attached by magnetism LASER-SMARTY2.TARGET 1 electronic target mark, attached by magnetism 1 case LASER-SMARTY2.TARGET-DIGITAL
TPI 182
Schaeffler Technologies
00019CE5
Application
The FAG Top-Laser SMARTY2 can be mounted in just a few seconds, Figure 3.
Figure 3 Mounting The laser can be clearly seen on the target marks. Once the laser beam is adjusted to coincide with the slots in the target marks, the machine is correctly aligned, Figure 4.
Figure 4 Alignment
Schaeffler Technologies
TPI 182
00019C07
00019BFE
Alignment
Battery, 1LR6 (AA) DC 1,5 V 8h +10 C to +40 C 2 78 635 nm to 670 nm 1 mW 10 m (maximum) Better than 0,5 mm or 0,2 145 mm86 mm30 mm 270 g ABS, Al
General rule for deviation, depending on belt type: less than 0,25 (4,4 mm/m).
TPI 182
Schaeffler Technologies
The robust, handy FAG Top-Laser TRUMMY2 is an optical-electronic manual measuring instrument for belt tension (strand force). The correct belt tension is an essential prequisite for achieving the maximum life of the belt drive. In addition, this also gives reduced wear of the drive components, lower energy costs and increased cost-efficiency. The FAG Top-Laser TRUMMY2 comprises a measurement probe without cable for direct connection, a measurement probe with cable for difficult to access locations and a manual control device that displays the relevant measurables for belt tension as a frequency in Hz or force in N. All the parts of the belt tension measuring device are supplied packed in a case, Figure 5. The simple and reliable user instructions are given in several languages. Do not look into the laser beam and do not point the laser beam into the eyes of other people. 1 manual control device 1 measurement probe for direct connection 1 measurement probe with cable 1 case LASER-TRUMMY2
Ordering designation
Manual control device Measurement probe for direct connection Measurement probe with cable Case
Schaeffler Technologies
TPI 182
00019C87
Alignment
Calibration
We recommend, in accordance with ISO 9001, that the belt tension measuring device should be checked or calibrated at intervals of no more than 2 years. The belt tension measuring device can be sent to us for calibration. Before sending the device, please contact our Technical Support. Calibration LASER-TRUMMY.CALI-CHECK Before calculating the belt tension, the belt mass and length must be entered. Vibration of the belt is then induced. The device measures the natural frequency by means of clock pulse light and uses this to determine the belt tension, Figure 6. This technique is less prone to disruptive influences in comparison with measurement using sound waves.
Figure 6 Measurement
10
TPI 182
Schaeffler Technologies
00019BFC
Schaeffler Technologies
TPI 182
11
Alignment
Caution
The FAG Top-Laser EQUILIGN, Figure 7, is an alignment system for coupled and decoupled shafts in motors, pumps, ventilators and gearboxes with rolling bearings. The advantages of the system are as follows: simple mounting error-free handling even by untrained personnel using step-by-step display on the manual control device automatic tolerance checking. A symbol indicates when the shafts are correctly aligned more precise alignment than with conventional methods rapid, simple measurement by means of Active Clock measurement mode robust control device. Watertight and insensitive to contamination in accordance with IP65 user interface in 19 languages easy generation of reports real time display of displacement in all axes. Do not look into the laser beam and do not point the laser beam into the eyes of other people.
12
TPI 182
Schaeffler Technologies
00019C8B
All the parts of the shaft alignment device are supplied packed in a case, Figure 8. Scope of delivery 1 manual control device 1 emitter/receiver including cable 2 m long 1 reflector 5 batteries 1 Allen key 1 cable for connecting USB memory stick to device 1 cable for connecting device to PC via USB port 2 brackets 2 chains, 300 mm long 4 posts, 115 mm long 1 tape measure 1 case LASER-EQUILIGN
00019C8D
Ordering designation
Manual control device Emitter/receiver Reflector Batteries, LR6 (AA) DC 1,5 V, 5 piece Allen key, 4 mm Cable for USB memory stick Cable for PC Bracket Chain, 300 mm long Post,115 mm long Tape measure Case
Schaeffler Technologies
TPI 182
13
Alignment
Replacement parts
Batteries and Allen keys are standardised and can be obtained from trade outlets. All other parts are available as replacement parts, see table.
Description Scope Designation of delivery Quantity 1 1 1 1 1 2 2 4 1 1 LASER-EQUILIGN-DEVICE LASER-EQUILIGN.TRANS LASER-EQUILIGN.REFLECT LASER-EQUILIGN.USB-CABLE LASER-EQUILIGN.PC-CABLE LASER.BRACKET LASER.CHAIN300-SET LASER.POST115-SET LASER.TAPE LASER-EQUILIGN.CASE
Manual control device Emitter/receiver with cable Reflector Cable for USB memory stick, 0,5 m long PC, 2 m long Bracket Chain, 300 mm long Post, 115 mm long Tape measure, 1 m long Case
Accessories
A comprehensive range of accessories is available in order to expand the possible applications of the base device FAG Top-Laser EQUILIGN, see tables and Figure 9, page 15. The accessories can be ordered as a set in a handy, robust case or as individual parts.
Description Scope Designation of delivery Quantity 2 2 4 4 4 4 1 LASER.CHAIN600-SET LASER.CHAIN1500-SET LASER.POST150-SET LASER.POST200-SET LASER.POST250-SET LASER.POST300-SET LASER.BRACKET-MAGNET
Chain Post
600 mm long 1500 mm long 150 mm long 200 mm long 250 mm long 300 mm long
14
TPI 182
Schaeffler Technologies
Accessories, set
Description
Designation
Chain Post
600 mm long 1500 mm long 150 mm long 200 mm long 250 mm long 300 mm long
LASER.ACCESS-SET
Chains, 600 mm Chains, 1500 mm Posts, 150 mm Posts, 200 mm Posts, 250 mm Posts, 300 mm Magnetic holder Case
Schaeffler Technologies
TPI 182
15
00019C90
Alignment
The emitter/receiver is mounted on the shaft of the non-movable side of the subassembly by means of a clamping device. The reflector is then mounted on the shaft of the movable opposing side, Figure 10. The emitter/receiver and manual control device are then connected to each other by means of a cable. The manual control device is switched on and the dimensions of the machine are inputted. A soft foot is defined as a machine foot that lifts off the floor when the foot screw connection is slackened. If a soft foot is present, this must be removed before alignment is carried out. Each individual foot screw connection is loosened and the device is monitored to see if it displays any changes between the foot screwed firmly into place and the loosened foot. The soft foot can then be eliminated using shims, page 21.
Emitter/receiver Reflector Soft foot, display Soft foot, foot screw connection
16
TPI 182
Schaeffler Technologies
00019DB8
Alignment
Once the soft foot has been eliminated, the alignment process can be started. During measurement, at least three positions are approached at different angles. These must be measured at an angle of at least 90. The intelligent control system prevents incorrect usage here. The actual condition of the subassembly is then displayed, Figure 11. Once the foot screw connections have been loosened, the vertical misalignment is first eliminated by means of shims. FAG Top-Laser EQUILIGN shows the displacement in real time. This means that the user can monitor on the display how the measurement results change as soon as the subassembly is moved. Horizontal adjustment is then carried out until the symbol with the thumb pointing upwards is displayed. Once the foot screw connections are tightened, the shafts are aligned.
Display of actual condition Foot screw connection Direction of vertical displacement Direction of horizontal displacement
Figure 11 Alignment
Schaeffler Technologies
TPI 182
17
00019DB8
Alignment
Compilation of results
After just five operating steps, the subassembly is aligned, Figure 12.
Input of dimensions Identification of soft foot Measurement Display of actual condition Display of displacement Symbol thumbs up = everything is OK
Finally, a control measurement is carried out and the measurement result is recorded with the aid of the report generator function integrated in the device.
18
TPI 182
Schaeffler Technologies
0001A4DC
Status displays Battery display Laser alignment, alignment status Keyboard Key elements Navigation keys: up, down, left, right Enter key Back key Delete key Menu key Alphanumeric keyboard Additional keys for functions: Dimensions, Measurement, Results, Soft foot, LiveMove 220 mm165 mm45 mm 742 g IP65
Schaeffler Technologies
TPI 182
19
Alignment
Emitter/receiver Measurement distance Dimensions (WHD) Mass Protection type Laser Principle Type Class Laser beam, wavelength Output power Detector Measurement range Resolution Accuracy Inclinometer Measurement range Resolution Reflector Design Accuracy Dimensions (WHD) Mass Protection type Case Dimensions (WHD) Mass Material User interface Language versions German, English, US English, Chinese (traditional), Chinese (simplified), Finnish, French, Indonesian, Italian, Japanese, Korean, Dutch, Polish, Portuguese, Russian, Swedish, Spanish, Thai, Czech 500 mm410 mm140 mm 4,1 kg ABS 90 mm roof prism 1% 100 mm41 mm35 mm 65 g IP67 0 to 360 1 Any, dynamically expandable 1 m 98% Coaxial, reflected laser beam Ga-Al-As semiconductor laser 2, FDA 21 CFR 1000 & 1040 675 nm, red, visible 1 mW 5 m (maximum) 107 mm70 mm49 mm 177 g IP67
20
TPI 182
Schaeffler Technologies
Shims FAG Top-Laser SHIM are used to eliminate vertical misalignment or soft feet. These shims are made from corrosion-resistant alloy steel and are available in seven thicknesses (0,05 mm, 0,1 mm, 0,2 mm, 0,5 mm, 0,7 mm, 1 mm 2 mm) and in four sizes (dimension c = 15 mm, 23 mm, 32 mm, 44 mm), Figure 13 and table, page 22.
1 case 360 shims: 20 shims each in three sizes (dimension c = 15 mm, 23 mm, 32 mm) and six thicknesses (0,05 mm to 1 mm) 1 extraction hook LASER.SHIM-SET As replacement parts, we supply 10 shims each in one of the 4 sizes and one of the 7 thicknesses. Ordering example 1: 10 shims with dimension c = 15 mm and 0,2 mm thickness LASER.SHIM15X0,20 Ordering example 2: 10 shims with dimension c = 44 mm and 0,1 mm thickness LASER.SHIM44X0,10
Ordering designation
Ordering designation
Schaeffler Technologies
TPI 182
21
00017A47
Alignment
Available shims
Designation
Dimensions a mm 55 55 55 55 55 55 55 75 75 75 75 75 75 75 90 90 90 90 90 90 90 125 125 125 125 125 125 125 b mm 50 50 50 50 50 50 50 70 70 70 70 70 70 70 80 80 80 80 80 80 80 105 105 105 105 105 105 105 c mm 15 15 15 15 15 15 15 23 23 23 23 23 23 23 32 32 32 32 32 32 32 44 44 44 44 44 44 44 Thickness mm 0,05 0,1 0,2 0,5 0,7 1 2 0,05 0,1 0,2 0,5 0,7 1 2 0,05 0,1 0,2 0,5 0,7 1 2 0,05 0,1 0,2 0,5 0,7 1 2
LASER.SHIM15X0,05 LASER.SHIM15X0,10 LASER.SHIM15X0,20 LASER.SHIM15X0,50 LASER.SHIM15X0,70 LASER.SHIM15X1,00 LASER.SHIM15X2,00 LASER.SHIM23X0,05 LASER.SHIM23X0,10 LASER.SHIM23X0,20 LASER.SHIM23X0,50 LASER.SHIM23X0,70 LASER.SHIM23X1,00 LASER.SHIM23X2,00 LASER.SHIM32X0,05 LASER.SHIM32X0,10 LASER.SHIM32X0,20 LASER.SHIM32X0,50 LASER.SHIM32X0,70 LASER.SHIM32X1,00 LASER.SHIM32X2,00 LASER.SHIM44X0,05 LASER.SHIM44X0,10 LASER.SHIM44X0,20 LASER.SHIM44X0,50 LASER.SHIM44X0,70 LASER.SHIM44X1,00 LASER.SHIM44X2,00
8 17 40 80 120 170 334 16 31 60 150 220 320 630 16 38 80 190 270 390 774 50 90 140 363 505 694 1362
22
TPI 182
Schaeffler Technologies
Schaeffler Technologies
TPI 182
23
Product overview
Services
Mounting
MOUNT-HOUR
Lubrication
ARCA-PUMP
Condition monitoring
CM-HOUR-ENGINEER
24
TPI 182
Schaeffler Technologies
0001A366
0001A364
0001A362
Services
In addition to alignment as a service, Schaeffler can provide numerous solutions for your specific requirements. Here are some examples from the product portfolio of Schaeffler Industrial Aftermarket.
Mounting
Our experienced fitters can support you in the mounting and dismounting of rolling bearings and advise you on the selection of suitable mounting tools. Correct mounting is an essential precondition for achieving the maximum operating life of bearings. In the case of the London Eye, Schaeffler supplied the rolling bearings and carried out the mounting operations, Figure 1.
Figure 1 Double row FAG spherical roller bearing in the London Eye
Lubrication
Unsuitable lubrication can impair the operating life of rolling bearings and cause damage. In order to achieve the most suitable lubrication, Schaeffler can provide specifically designed and tested greases, Figure 2.
Schaeffler Technologies
TPI 182
25
000192B4
00017E25
Services
The 17 different greases cover almost all applications. They are developed by experienced application engineers and are produced by the best manufacturers in the market. Different greases are used depending on the particular application. At high operating temperatures, the thermally stable special grease Arcanol TEMP120 is used. Rolling bearing greases under the name Arcanol are subject to 100% quality inspection. The inspection methods at Schaeffler are among the most demanding in the market. As a result, rolling bearing greases Arcanol fulfil the highest quality requirements. The malfunction-free and optimised operation of complex machinery and plant can only be achieved by means of condition-based maintenance. In many cases, Schaeffler uses vibration diagnosis. For example, FAG SmartCheck is an innovative measuring system for real time monitoring with a patented diagnosis technology. Due to the low purchase costs, it can be used economically even on smaller subassemblies. The compact measuring device can be installed quickly, is easy to use and contributes through its trendsetting characteristics to process optimisation and the reduction of life cycle costs. In this way, you receive the best information on the condition of your machinery, Figure 3.
Condition monitoring
26
TPI 182
Schaeffler Technologies
0001A1D2
Notes
Schaeffler Technologies
TPI 182
27
Notes
28
TPI 182
Schaeffler Technologies
Schaeffler Technologies
TPI 182
29
Notes
30
TPI 182
Schaeffler Technologies
Schaeffler Technologies
TPI 182
31
Notes
32
TPI 182
Schaeffler Technologies
Further information
Industrial Aftermarket Products and services for your success www.schaeffler.com/services
Schaeffler Mounting Toolbox Virtual Plant: About the Mounting Service http://mounting-toolbox.schaeffler.com
Schaeffler Technologies AG & Co. KG Postfach 1260 97419 Schweinfurt Germany Georg-Schfer-Strae 30 97421 Schweinfurt Germany Phone Fax E-mail +49 2407 9149-66 +49 2407 9149-59 [email protected]
Every care has been taken to ensure the correctness of the information contained in this publication but no liability can be accepted for any errors or omissions. We reserve the right to make technical changes. Schaeffler Technologies AG & Co. KG Issued: 2013, July This publication or parts thereof may not be reproduced without our permission. TPI 182 GB-D
Internet www.schaeffler.com/services