Unisonic Technologies Co., LTD: Reverse Blocking Triode Thyristors

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

UNISONIC TECHNOLOGIES CO.

, LTD MCR106
REVERSE BLOCKING TRIODE THYRISTORS
DESCRIPTION

SCR

PNPN devices designed for high volume consumer applications such as temperature, light and speed control; process and remote control, and warning systems where reliability of operation is important.

FEATURES

* Glass-passivated surface for reliability and uniformity * Power rated at economical prices * Practical level triggering and holding characteristics * Flat, rugged, thermopad construction for low thermal resistance, high heat dissipation and durability

ORDERING INFORMATION
Package TO-126 TO-126 Pin Assignment 1 2 3 K A G K A G Packing Bulk Bulk

Ordering Number Lead Free Halogen Free MCR106L-6-T60-K MCR106G-6-T60-K MCR106L-8-T60-K MCR106G-8-T60-K Note: Pin assignment: G: Gate K: Cathode A: Anode

www.unisonic.com.tw Copyright 2011 Unisonic Technologies Co., Ltd

1 of 3
QW-R301-001.C

MCR106
ABSOLUTE MAXIMUM RATINGS (TJ=25, unless otherwise specified)

SCR

PARAMETER SYMBOL RATINGS UNIT 400 V Peak Repetitive Forward and Reverse Blocking MCR106-6 VDRM, VRRM Voltage (Note 1) (TJ=110, RGK=1k) MCR106-8 600 V RMS Forward Current (All conduction Angles) IT(RMS) 4 A Average Forward Current (TC=93 or TA=30) IT(AV) 2.55 A Peak Non-repetitive Surge Current 25 A ITSM (1/2 Cycle, 60Hz, TJ=-40 ~ +110) Circuit Fusing Considerations (t=8.3 ms) I2t 2.6 A2 S Peak Gate Power PGM 0.5 W Average Gate Power PG(AV) 0.1 W Peak Forward Gate Current IGM 0.2 A Peak Reversed Gate Voltage VRGM 6 V Mounting Torque (Note 2) 6 In. lb. Junction Temperature TJ +110 Storage Temperature TSTG -40 ~ +150 Note 1. VDRM and VRRM for all types can be applied on a continuous basis. Ratings apply for zero or negative gate voltage; however, positive gate voltage shall not be applied concurrent with negative potential on the anode. Blocking voltages shall not be tested with a constant current source such that the voltage of the devices are exceeded. 2. Torque rating applies with use of compression washer (B52200-F006 or equivalent). Mounting torque in excess of 6 in. lb. does not appreciably lower case-to-sink thermal resistance. Anode lead and heatsink contact pad are common. For soldering purposes (either terminal connection or device mounting), soldering temperatures shall not exceed +200. For optimum results, an activated flux (oxide removing) is recommended. 3. Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied.

THERMAL DATA
PARAMETER SYMBOL JA JC RATINGS 75 3 UNIT /W /W

Junction to Ambient Junction to Case

ELECTRICAL CHARACTERISTICS (TC=25 and RGK=1000 , unless otherwise specified)


TEST CONDITIONS TJ=25 TJ=100 VAK=7V, RL=100 VAK=7V, RL=100, TC=-40 VAK=7V, RL=100, TC=25 VAK=Rated VDRM, RL=100, TJ=110 VAK=7V, TC=25 TJ=110 MIN TYP MAX UNIT 10 A 200 A 2 V 200 A 500 1 V V 5 mA 10 V/s

PARAMETER SYMBOL Peak Forward or Reverse Blocking IDRM,IRRM Current (VAK=Rated VDRM or VRRM) Forward On Voltage (ITM=4A peak) VTM Gate Trigger Current (continuous DC) IGT (Note) Gate Trigger Voltage (continuous DC) VGT Gate Non-Trigger Voltage VGD Holding Current IH Forward Voltage Application Rate dv/dt Note: RGK current is not included in measurement.

0.2

UNISONIC TECHNOLOGIES CO., LTD


www.unisonic.com.tw

2 of 3
QW-R301-001.C

MCR106
TYPICAL CHARACTERISTICS
Maximum Case Temperature 110 106 102 98 94 90 86 90 =30 60 120 dc 180 50
0

SCR

Maximum Case Temperature 110 90

f=60Hz

70 =30 =60 =90 =180

f=60Hz

dc

80 0 0.4 0.8 1.21.6 2.02.4 2.83.23.6 4.0 Average Forward Current, IT (AV) (A)

30 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Average Forward Current, IT (AV) (A)

UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.

UNISONIC TECHNOLOGIES CO., LTD


www.unisonic.com.tw

3 of 3
QW-R301-001.C