Test Kits & Meters
Test Kits & Meters
Test Kits & Meters
brand filter
holder Model No. SDI-2000-MIL
(SDI-FH Millipore filter holder is pictured below)
Optional Booster Pump Accessory:
Pump Assembly Kit for testing with less
than 30 psi. Assembled with Booster Pump,
Power Supply, Pressure Regulator:
SDI-PU: 115-120VAC, 60Hz
SDI-PE: 230VAC, 50Hz
SDI-PJ: 100VAC, 50-60Hz
Filters and Spare Parts for SDI Kit
Model No. Description
SDI-045SD
SDI-FH2
SDI-FH
SDI-045
Filters for SDI Testing, 0.45 Micron, 47 mm,
Package of 100
SDI-FH2 Filter Holder for SDI Kit (SDI-2000)
SDI-FH Filter Holder for SDI Kit (SDI-2000-MIL)
Detailed Silt Density Index measurement instructions and calculations are shown in the technical section of our catalog.
Si l t Densi t y I ndex Test i ng
Portable Automatic SDI Testers
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-2
Simple SDI
Performs SDI 5, 10 and 15 minute tests with both 100 mL
and 500 mL sample size tests.
Unattended operation. Start the test and return in 15
minutes to see the results.
Real-time display of results including SDI, current flow
rate, and elapsed time. End of test display includes SDI
5, 10 & 15 with 100 mL and 500 mL results.
Accurate and consistent results.
Batter powered for portability conduct tests anywhere.
Uses standard 47 mm membrane filters.
Each model includes a Power Supply, Battery Charger, Accessory
Case, pack of 100 each .45 micron 47 mm membrane filters,
Special Tweezers for handling of the membranes, and a 50
micron pre-filter.
Product Specifications
Model No. Description
Y-SIMPLESDI-110 Portable & Automated Silt Density Index Meter, 110 VAC
Y-SIMPLESDI-220 Portable & Automated Silt Density Index Meter, 220 VAC
Spare Parts and Options
SDI-045
Filters for Silt Density Index Testing, 0.45 Micron, 47 mm,
Package of 100
K2305JJ Pre-filter 5M inline, Omnipure
182-11001 Battery 6V 1.3 AH SLA type
182-40005
Booster pump for 110Vac, used when source water is less
than 35 PSI
182-40025
Booster pump for 220Vac, used when source water is less
than 35 PSI
182-30059 Pre-Filter 50m Inline
182-30050 Pre-Filter 50m Inline QC
182-11005 Power Supply/Battery Charger (110 Vac-60Hz)
Si l t Densi t y I ndex Test i ng
EZ & Enhanced Automatic SDI Monitors
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-3
The EZ and Enhanced SDI monitors automatically and consistently monitor the silt density
index of RO feedwater. Monitoring the SDI is very useful to determine fouling problems
before the membranes need replacement. Applied Membranes, Inc. now offers an
economical, effective, and easy way to monitor the SDI of the feedwater entering into the
membranes. Also ask us about our manual SDI Test Assembly in stock available for
immediate delivery.
Distinguishing Features:
Automatic Easy to Install and Operate
Uses standard filter media
Replacing the media is an easy 2-minute process
Monitor housed in NEMA 4X enclosure
Designed for permanent installation
SDI can be taken by pushing a button
Display equipped with LED backlight, so results can be seen in any environment
Test pressure is controlled with an internal pressure regulator, which can accommodate
inlet pressures above 1000 psi.
Product Specifications
Model No. Description
Y-EZSDI* EZ SDI Automatic Silt Density Index Monitor, Performs 1 test a time
Y-ENHSDI* Enhanced SDI Automatic Silt Density Index Monitor, Performs up to 4 tests a time
Y-ENHSDI-SS Sample sequencer for Enhanced SDI
* Analog output option available. Add -Analog to the end of the part number when ordering (Example: Y-ENHSDI-Analog).
Filter Options
The Y-EZSDI is available with another filter option. The original filter holder accepts standard 25 mm disk filters. It can also be
ordered to accept disposable 25 mm cartridges (Y-EZSDIC). Use of the disposable filter eliminates the handling of individual
filter disks and the o-ring associated with the standard filter holder. Specify a filter option when ordering.
Model No. Description
Y-EZSDI Standard Filter Option, Shipped with 25 mm Filter Disks
Y-EZSDIC Disposable Cartridge Option, Shipped with 25 mm Cartridges
Replacement Kits
Model No. Description
EZ-1D-2YSPK Two-Year Spare Parts Kit for Y-EZSDI
Includes (2) EZSDI-439, (1) EZSDI-360, (2) EZSDI-466, (1) EZSDI-525, (1) EZSDI-258, (1) EZSDI-465, (2) EZSDI-903, (1) EZSDI-902, and (1) EZSDI-112
EZ-4-2YSPK Two-Year Spare Parts Kit for Y-ENHSDI Includes (2) EZSDI-439, (1) EZSDI-498, (1) EZSDI-507, (1) EZSDI-525, (1) EZSDI-258, (1) EZSDI-465,
(2) EZSDI-903, (1) EZSDI-902, (1) EZSDI-536, and (1) EZSDI-112
Spare Parts
Model No. Description Qty. in
Pkg.
EZSDI-439 Fuse 2 Amp, 250v 1
EZSDI-257 ID Drain Tubing 5 Feet
EZSDI-133 OD Vent Tubing, 250 PSI 100 Feet
EZSDI-360 Filter Holder with Drain Tube (for Y-EZSDI) 1
EZSDI-448 25 mm Replacement Filters (for Y-EZSDI) 100
EZSDI-466 Silicone O-Ring (for Y-EZSDI) 1
EZSDI-496 Disposable Filter Cartridges (EZSDIC & EHNSDI) 100
EZSDI-498 Cartridge Filter Fitting (EZSDIC & EHNSDI) 1
Model No. Description Qty. in
Pkg.
EZSDI-507 Cartridge Filter Adapter (EZSDIC & EHNSDI) 1
EZSDI-903 Manifold Solenoid Valve with Teflon Plunger 1
EZSDI-902 Drain Solenoid Valve with Teflon Plunger 1
EZSDI-536 Vent Solenoid Valve with Teflon Plunger (for Y-ENHSDI) 1
EZSDI-112 Water Vent Tubing Flow Orifice 1
EZSDI-134 Air and Water Vent Tubing Bulkhead connector 1
EZSDI-256 Drain Tube Hose Barb 1
Poc k et Wat er Test er s
HM Digital & Hanna
TDS, pH, & ORP Testers
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-4
TDS Pocket Testers for Testing Total Dissolved Solids in Water
Model No. Description Range Brand
TDS-EZ Pocket TDS Tester ideal for end users 0-9990 ppm HM Digital
TDS-3 Pocket TDS with ATC, includes case 0-9990 ppm HM Digital
TDS-4 Pocket TDS small & light w/ATC 0-9990 ppm HM Digital
TDS-4TM Pocket TDS small & light w/ digital therm. C & ATC 0-9990 ppm HM Digital
TDS-4TM/A Pocket TDS small & Light w/ digital therm. for Aquarium 0-9990 ppm HM Digital
AP-1 Pocket TDS Tester w/ digital temp. for ATC 0-5000 ppm HM Digital
AP-2 Pocket Electrical Conductivity Tester w/ digital temp. for ATC 0-9999 S HM Digital
HI98301 Pocket TDS Tester 10-1990 ppm Hanna
HI98302 Pocket TDS Tester 100-10,000 ppm Hanna
HI98203 Pocket TDS Tester SalinTest for NaCL (Aquarium) 0.00-1.00 pNaCL Hanna
TDS-EZ
TDS-3 TDS-4
TDS-4TM
TDS-4TM/ A
AP-1
AP-2
HI98301, 02, & 03
pH Pocket Testers for Testing pH Levels in Water
Model No. Description Brand
PH-80
PH-200
HI98107
PH-80
Economically priced water resistant pH meter
measures pH (0-14) & temperature (1-80C; 33-176F)
with auto-off, data-hold function, and low-battery
indicator.
HM Digital
PH-200
Waterproof pH meter measures pH (0-14) &
temperature (0-80C; 32-176F) with auto-off, data-
hold function, and low-battery indicator.
HM Digital
HI98107
Pocket pH tester with LCD measures pH (0-14).
Supplied with protective cap, calibration screwdriver
& batteries. Must be calibrated with a buffer solution.
Hanna
ORP Pocket Testers for Testing Oxidation Reduction Potential (Redox) in Water
Model No. Description Range Brand
ORP-200
HI98201
ORP-200
Pocket ORP with temperature display,
waterproof, 1 mV Resolution,
2mV accuracy
-999 to
+1000 mV
HM Digital
HI98201
Pocket ORP Tester , 1 mV Resolution,
5 mV accuracy
999 mV Hanna
Poc k et Wat er Test er s
HM Digital & Hanna
Combo & Temperature Meters
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-5
Multi-Measurement Pocket Testers Combo Meters for Water Quality Testing
Model No. Description Brand
COM-100
HI98129 &
HI98130
HI98121
COM-100
Waterproof EC/TDS/Temp Combo Meter Measures:
Electrical Conductivity, Range: 0 - 9990 S; 0 - 9.99 mS
TDS, Range: 0 - 8560 ppm (mg/ L); 0 - 8.56 ppt
Temperature, Range: 0-80 C; 32-176 F
HM
Digital
HI98129
Waterproof pH/Conductivity/TDS Tester Measures:
pH, Range: 0.00 to 14.00 pH
EC, Range: 0 to 3999 S/cm
TDS, Range: 0 to 2000 ppm
Temperature, Range: 0.0 to 60.0C / 32 to 140.0F
Hanna
HI98130
Waterproof pH/Conductivity/TDS Tester Measures:
pH, Range: 0.00 to 14.00 pH
EC, Range: 0.00 to 20.00 mS/ cm
TDS, Range: 0.00 to 10.00 ppt
Temperature, Range: 0.0 to 60.0C / 32 to 140.0F
Hanna
HI98121
Waterproof Combo pH/ORP/Temp Tester With
Automatic Temperature Compensation & Automatic
Calibration Measures:
ORP, Range: 1000 mV
pH, Range: -2.00 to 16.00 pH
Temperature, Range: -5.0 to 60.0C / 23.0 to 140.0F
Hanna
Pocket Thermometers for Checking Water Temperature
Model No. Description Range Brand
TM-1
Industrial Grade Digital F/C Thermometer, SS Probe w/ 20
Cable, 1C Accuracy, 0.1F/C Resolution, Case Included
-58 to 482F
-50 to 250C
HM Digital
HI98502
Checktemp
Di gi t al Test er s
Hand-Held Multi-Measurement Testers
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-6
Ultrameter II Series Multi-Measurement Testers by Myron L
Ultrameter II Series Hand-Held Testers Feature: 4-Digit Display, Auto-ranging, Adjustable ATC, Adjustable
Cond./TDS Ratio, 100-Reading Memory, Low Battery Indicator, Auto-Off.
Model No. Description Image
4PII
Measures:
Conductivity: 0-9,999 S/ cm, 10-200 mS/ cm
Resistivity: 10K-30M
TDS: 0-9,999 ppm, 10-200 ppt
Temperature: 32-160F, 0-71C
(RPR)
6PIIFC
Measures:
Conductivity: 0-9,999 S/ cm, 10-200 mS/ cm
Resistivity: 10K-30M
TDS: 0-9,999 ppm, 10-200 ppt
Free Chlorine: 0.0010.00 ppm
pH: 0-14
ORP: 999mV
Temperature: 32-160F, 0-71C
RPR
Replacement PH/ORP Probe for 6PIIFC Series
TECHPRO II Series Conductivity/TDS/pH Testers by Myron L
TECHPROII Series Testers Feature: Memory storage (20 readings), Internal Sensor to prevent breakage, Auto
shut-off for longer battery life, Lightweight and fits in the palm of your hand, Waterproof case.
Model No. Measures Image
TP1 Conductivity: 0-9,999 S/ cm, 10-20 mS/ cm
TDS: 0-9,999 ppm, 10-20 ppt
Temperature: 32-160F, 0-71C
TPH1 Conductivity: 0-9,999 S/ cm, 10-20 mS/ cm
TDS: 0-9,999 ppm, 10-20 ppt
pH: 0-14
Temperature: 32-160F, 0-71C
TH1
pH: 0-14
Temperature: 32-160F, 0-71C
Ultrameter III 9P - AHL Titration Kit by Myron L
The Ultrameter III performs in-cell conductometric titrations and provides a
convenient way to determine alkalinity, hardness and LSI in the field. All required
reagents and equipment are included in the 9P titration kit. Features: LSI Calculator,
Autoranging, Adjustable ATC and Cond/TDS conversion ratios, 100-Reading Memory
with Date & Time stamp, pH Calibration , Auto-off and Low Battery indicator.
Model No. Measures:
9PTK Conductivity: 09,999 S/ cm, 10200 mS/ cm
in 5 autoranges
Resistivity: 10 K30 M
TDS: 09,999 ppm 10200 ppt in 5 autoranges
pH: 014 pH
ORP: 999 mV
Free Chlorine: 0.0010.00 ppm (5<pH<9)
Alkalinity Titration: 10-800 ppm
Hardness Titration: 0-1710 ppm 0-100 grains
LSI Titration: -10 to +10
Temperature: 071C/32160F
Myr on L
Anal og Test er s
Hand-Held Multi-Measurement Testers
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-7
pDS pH/Conductivity/TDS Meters by Myron L
Model No. Description
T2/PH pDS pH/ TDS Meter: 0-50, 500, 5,000 ppm; 2-12 pH
T6/PH pDS pH/TDS Meter: 0-5,000 ppm; 2-12 pH
EP11/PH pDS pH/ Conductivity Meter: 0-10, 100, 1,000, 10,000 M/ S; 2-12 pH
DS Conductivity/TDS Meters by Myron L
Model No. Description
RO-1 RO METER DS TDS Meter: 0-1,250 ppm (with color band)
RO-1NC RO METER DS TDS Meter: 0-1,250 ppm (no color band)
EP DS Conductivity/Resistivity Meter: 0-0.5, 5, 50, 500, 5,000 M/S; 2-30 M
EP-10 DS Conductivity Meter: 0-10, 100, 1,000, 10,000 M/ S
532T1 DS TDS Meter: 0-50, 500, 5,000 ppm
532T2 DS TDS Meter: 0-25, 250, 2,500 ppm
512T5 DS TDS Meter: 0-5,000 ppm
512T10 DS TDS Meter: 0-10,000 ppm
532M1 DS Conductivity Meter: 0-50, 500, 5,000 M/S
RE-10
Range Extender to increase conductivity/TDS range by a factor of 10
when inserted into the sample filled cell cup. (Not available for model 512T10)
Carrying Cases for Myron L Testers
Model No. Description
UPP For all digital handheld models. Small hard foam-lined protective carry case.
UCC
For all digital handheld models. Soft protective Nylon padded case with zipper closure and belt
clip for hands-free mobility.
PTP For all analog handheld models. Small hard foam-lined protective carry case.
UPP
UCC
PTP
Hanna Test Ki t s & Phot omet er s
Chemical Test Kits and Portable Photometers
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-8
Chemical Test Kits by Hanna Instruments
Model No. Description Method
Approx.
#of Tests
Range
HI38054 Ozone Test Kit Checker Disc 100 0.0-2.3 mg/ L
HI3812 Hardness Test Kit Titration 100 0.0-30.0, 0-300 mg/ L
HI3815 Chloride Test Kit Titration 110 0-100, 0-1000 mg/ L
HI3831F Free Chlorine Test Kit Colorimetric 50 0.0-2.5 mg/L
HI3824 Ammonia Fresh Water Test Kit Colorimetric 25 0.0-2.5 mg/ L
HI3847 Copper High Range Test Kit Colorimetric 100 0.0-2.5 mg/L
HI3856 Copper Low Range Test Kit Colorimetric 100 0.00-0.25 mg/ L
HI93701-01 Free Chlorine Reagent Test Kit DPD 100 0.00-5.00 mg/ L
HI93711-01 Total Chlorine Reagent Test Kit DPD 100 0.00-5.00 mg/ mL
HI93734-01 Free & Total Chlorine, HR Reagent Test Kit DPD 100 0.00-10.00 mg/ L
HI93705-01 Silica Reagent Test Kit LR Hetetopoly Blue 100 0.00-2.00 mg/ L
HI93719-01 Hardness (MG) Reagent Test Kit EDTA 100 0.00-2.00 mg/ L
HI93720-01 Hardness & Calcium Reagent Test Kit Calmagite 100 0.00-2.70 mg/ L
HI93702-01 Copper HR Reagent Test Kit Bicinchoninate Acid 100 0.00-5.00 mg/L
HI93746-01 Iron (Fe LR) Reagent Test Kit TPTZ 50 0.00-1.00 mg/ L
HI93721-01 Iron (Fe HR) Reagent Test Kit Phenanthroline 100 0.00-5.00 mg/ L
HI93728-01 Nitrate Reagent Test Kit Cadmium Reduction 100 0.0-30.0 mg/L
HI93706-01 Phosphorous Reagent Test Kit Amino Acid 100 0.0-15.0 mg/L
HI93710-01 pH Reagent Test Kit Phenol Red 100 5.9(6.5)-8.5 pH
HI3812
HI3815
HI3831F
HI3824
HI3847
HI3856
HI93734
HI93705, HI93719, HI93720, HI93702, HI93746,
HI93728, HI93706, HI93710, HI93721
Portable Photometers by Hanna Instruments
Model No. For Testing Range
CAL CHECK
User calibration
Certified calibration and
verification standards
BEPS (Battery Error
Prevention System)
TIMER function
Auto shut-off
GLP Features
HI96701 Free Chlorine Photometer 0.00-5.00 mg/L (ppm)
HI96711 Free and Total Chlorine Photometer 0.00-5.00 mg/L
HI96734 Free and Total Chlorine Photometer, High Range 0.00-10.00 mg/ L
HI96706 Phosphorous Photometer 0.00-15.00 mg/L (ppm)
HI96738 Chlorine Dioxide Photometer 0.0-2.00 mg/ L
HI96727 Color of Water Photometer 0-500 PCU
HI96747 Copper Photometer, Low Range 0.00-1.50 mg/L
HI96732 Dissolved Oxygen Meter 0.00-10.00 mg/L (ppm)
HI96719 Hardness Meter 0.00-2.00 mg/L
HI96720 Ca Hardness Photometer, Standard Method 0.00-2.70 mg/L
HI96721 Iron Photometer, High Range 0.00-5.00 mg/L
HI96728 Nitrate (as Nitrogen) Photometer 0.00-30.0 mg/L
HI96705 Silica Colorimeter 0.00-2.00 mg/L (ppm)
Hac h Test Ki t s & Col or i met er s
Chemical Test Kits and Portable Colorimeters
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-9
Chemical Test Kits by Hach
Model No. Description Range #of Tests
2601300 pH Color-Changing Paper Strips 0 14 pH 100 Strips
37633 pH Color-Changing Paper for Sewage Water 4.5 7.5 pH
(5) 15 Rolls
(Approx. 450)
2444301 Alkalinity Test Kit
5-100 mg/L Alkalinity (P)
20-400 mg/L Total (MO) as CaCO3
100
144001
Chloride (Low Range) Silver Nitrate Titrant Test Kit with Low and
High Test Ranges
Low: 5 - 100 mg/L Cl-
High: 20 - 400 mg/L Cl-
100
223101 Chlorine (Free & Total) Powder DPD Reagent Color Disc Test Kit 0 - 3.4 mg/L 50F, 50T
2194100 Copper (Free & Total) Powder DPD Reagent Color Disc Test Kit 0 - 4 mg/L 50F, 50T
1453-00 Total Hardness (as CaCO3) Drop Count Titration Test Kit 1 - 30 gpg 100
145700
Hardness, Total & Calcium (as CaCO3) Drop Count Titration/EDTA
Test Kit
1 - 20 gpg CaCO3 100
2291700
Hydrogen Peroxide (as HO) Drop Count Titration Test Kit with
Low and High Test Ranges
Low: 0.2 - 2.0 mg/L
High: 1 - 10 mg/L
100
146400 Iron Color Disc Test Kit 0.1 - 5 mg/L 100
1416100 Nitrogen, Nitrate Color Disc Test Kit with Low and High Test Ranges
Low: 0.02 - 1 mg/L NO3-N
High: 0.2 - 10 mg/L NO3-N
50
225001
Phosphate Test Kit, Total Ortho-/Meta- as PO4
3-
(requires hot acid
digestion) with Low, Meidum and High Test Ranges
Low: 0.02 1; Medium: 0.1 5;
High: 1-40
50 C/T**
1455400 Silica Color Disc Test Kit with Low and High Test Ranges
Low: 1 - 40 mg/L SiO2
High: 20 - 800 mg/L SiO2
100
225100 Sulfate (as SO4
2-
) Extinction/Turbidimetric Test Kit 50 - 200 mg/L 100
2518050 Ozone AccuVacColor Disc Test Kit 0.05 - 1.6 mg/L O3 25
2601300 37633 2444301 144001 2231-01 1453-00
1457-00 14161-00 14554-00 2251-00 25180-50
Hach DR/800 Portable Colorimeter Series
DR/800 Portable Colorimeter Series offers three models (20, 50, or 90 methods) with automatic
wavelength selection, based on the test selected. Its compact design provides true hand-held
analysis for use anywhere. LCD display shows results, parameter, name, and unit.
Preprogrammed: ready-to-use out of the box .
Dustproof, waterproof, shockproof, worry-free (designed to meet IP67 standards)
Full datalogging and RS232 interface capabilities
Simple menu-driven, step-by-step analysis
Model No. Description Wavelength Range
4847000 DR/890 Portable Colorimeter 420, 520, 560, 610 nm
4845000 DR/850 Portable Colorimeter 520, 610 nm
4844000 DR/820 Portable Colorimeter 520 nm
Each Colorimeter comes with two 1-inch glass sample cells marked at 10, 20 and 25 mL, two 1 cm plastic sample cells, a 16-mm
COD/Test 'N Tube adapter, 4 AA alkaline batteries, and illustrated instrument and procedure manuals. European CE mark.
Tur bi di met er & St andar d Sol ut i ons
Turbidimeter & Calibration and Buffer Solutions
Visit us on the web for our complete product line and in-depth technical information. www.appliedmembranes.com
(760) 727-3711 FX: (760) 727-4427
[email protected]
ARE TRADEMARKS OF APPLIED MEMBRANES, INC. 2012
Page 8-10
Hach 2100Q Portable Turbidimeter
The 2100Q Portable Turbidimeter offers ease of use and accuracy in turbidity
measurement, giving you accurate results every time.
Easy on-screen assisted calibration and verification
Accurate for rapidly settling samples
Convenient data logging for up to 500 measurements
Optical system for precision in the field
Model No. Description Range Accuracy
2100Q01 Portable Turbidimeter w/ On-Screen Calibration &
Verification and Data Logging. 0 - 1000 NTU
2 % of reading
plus stray light
2100Q01USB* 2100Q Portable Turbidimeter with USB +Power Module
* The USB+Power Module provides additional benefit by allowing the user to transfer data to a PC in XML format, transfer data to the Citizen
PD-24 printer (2960100), operate the instrument on line power (100-240Vac, 50/ 60 HZ), charge NiMH batteries (2971304),perform firmware
updates, and quickly enter Sample and User IDs with the optional barcode scanner (LZV566).
TDS Calibration Solutions by Myron L
442 Natural Water Standard Solution is NIST Traceable and is used in calibrating many test
instruments. It is the best choice when measuring boiler and cooling water samples, city water
supply, lakes, wells, etc. "442" refers to the combination of salts mixed with deionized water to
comprise this standard: 40% sodium sulfate, 40% sodium bicarbonate, 20% sodium chloride. A
combination of standard salts is necessary since natural water salt type and concentration can
vary greatly by location.
AMI Model No. Myron L Model No. Calibration Value Volume
T-TC0015 442-15Q 15ppm/23.8S 1 Quart
T-TC0030 442-30Q 30ppm/46.7S 1 Quart
T-TC0300 442-300Q 300ppm/445S 1 Quart
T-TC0500 442-500Q 500ppm/731S 1 Quart
T-TC1500 442-1500 1,500ppm/2,060S 1 Quart
T-TC3000 442-3000 3,000ppm/3,900S 1 Quart
T-TC30000 442-3000Q 30,000ppm/30,100S 1 Quart
pH Buffer Solutions by Myron L
pH Buffer Solutions 4, 7 and 10 are mold inhibited and accurate to within +0.01 pH units @ 25C.
Myron L Buffers are traceable to NIST certified pH references and are color-coded for instant
identification.
AMI Model No. Myron L Model No. Calibration Value Liquid Color Volume
T-PHB4 PH4 pH 4 Red 1 Quart
T-PHB7 PH7 pH 7 Yellow 1 Quart
T-PHB10 PH10 pH 10 Blue 1 Quart
ORP Standard Test Solutions by Hanna
ORP standard solutions allow you to test the precision of ORP electrodes. For example, by
immersing the electrode in HI 7020 solution, you should read within the 200 to 275 mV range
(@20C/ 68F). If the reading is outside the indicated interval, clean and condition your ORP
electrode in HANNApretreatment solution.
Model No. Description Volume
HI7020M ORP Test Solution at 200/275 mV (@20C) 230 mL bottle
HI7021M ORP Test Solution at 240 mV (@20C) 230 mL bottle
HI7022M ORP Test Solution at 470 mV (@20C) 230 mL bottle
HI7092M Oxidizing Pretreatment Solution 230 mL bottle
HI7091M Reducing Pretreatment Solution 230 mL bottle