Indoor Units R-410A FTX-GV1B

Features
Flat front panel: its stylish appearance blends easily within any interior dcor and is more easy to clean. Lightweight and compact Consumes up to 30% less energy than non-inverter units Dual air discharge flow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Indoor unit On/Off switch Indoor unit silent operation Titanium apatite photocatalytic air purification filter Anticorrosion treatment of outdoor heat exchanger fin Powerful mode can be selected for rapid cooling or heating Energy saving during stand by mode: reduction of energy from 10W to 2W

A t i y n k U S B 1 r AVt o 0G i o 1- l d4X npT- R FIS

1
1

optional

5 steps

standard

Split Sky Air Indoor Units

Indoor Units R-410A FTX-GV1B

2
2-1

Specifications
FOR INDOOR UNITS ONLY
Cooling Heating kW kW
FTX20GV1B FTX25GV1B FTX35GV1B

Nominal input (Indoor only)

0.04 0.04
FTX20GV1B

0.04 0.04
FTX25GV1B

0.04 0.04
FTX35GV1B

3 1
2

2-2
Casing

TECHNICAL SPECIFICATIONS
Colour Packing Height Width Depth Unit Height Width Depth mm mm mm mm mm mm kg kg Length Nr of Rows Fin Pitch Tube type Fin Type mm Nr of Stages mm

White 344 840 263 283 770 198 7 11 610 2 1.4 14 344 840 263 283 770 198 7 11 610 2 1.4 14 Hi-XA (7) ML fin (Multi louvre) Cross flow fan 1 High Medium Low m/min m/min m/min 9.1 7.4 5.9 4.7 9.4 7.8 6.3 5.5 321 261 208 166 331 276 222 194 1 1 9.2 7.6 6.0 4.8 9.7 8.0 6.3 5.5 325 268 212 169 342 283 222 194 1 MM6C02J2V 5 steps, quiet, auto 1,210 990 780 630 1,260 1,090 920 820 16 1,250 1,030 820 630 1,300 1,110 920 820 16 1,300 1,070 850 680 1,340 1,150 960 850 16 rpm rpm rpm 1 9.3 7.7 6.1 4.9 10.1 8.4 6.7 5.7 328 272 215 173 356 295 235 201 1 344 840 263 283 770 198 7 11 610 2 1.4 14

Dimensions

Weight Heat Exchanger

Unit Packed Unit Dimensions

Fan Air Flow Rate

Type Quantity Cooling

Silent m/min Operation Heating High Medium Low m/min m/min m/min

Silent m/min Operation Cooling High Medium Low cfm cfm cfm

Silent cfm Operation Heating High Medium Low cfm cfm cfm

Silent cfm Operation Fan Motor Quantity Model Number of steps Motor Speed (cooling) High Medium Low

Silent rpm Operation Speed (heating) High Medium Low rpm rpm rpm

Silent rpm Operation Fan Motor Output (high) W

Split Sky Air Indoor Units

Indoor Units R-410A FTX-GV1B

2
2-2
Cooling

Specifications
TECHNICAL SPECIFICATIONS
Sound Power Sound Pressure High High Medium Low dBA dBA dBA dBA
FTX20GV1B FTX25GV1B FTX35GV1B

55 39 33 25 22 55 39 34 28 25

56 40 33 26 22 56 40 34 28 25 R-410A

57 41 34 27 23 57 41 35 29 26

1
2
Heating

Silent dBA Operation Sound Power Sound Pressure High High Medium Low dBA dBA dBA dBA

Silent dBA Operation Refrigerant Piping connections Type Liquid (OD) Gas Drain Heat Insulation Air Filter Air direction control Temperature control Standard Accessories Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Diameter (OD) Diameter (OD) Diameter (OD) mm mm mm

6.35 9.52 18

6.35 9.52 18 Both liquid and gas pipes Removable/washable/Mildew proof Right, Left, Horizontal, Downward Microcomputer control Installation manual

6.35 9.52 18

1 1 1 2 1 1 2 2
FTX20GV1B

1 Operation manual 1 Wireless remote control 1 Batteries 2 Remote control holder 1 Mounting plate 1 Fixing screw for indoor unit 2 Titanium apatite photocatalytic air purification filter 2
FTX25GV1B

1 1 1 2 1 1 2 2
FTX35GV1B

2-3

ELECTRICAL SPECIFICATIONS
Name Phase Frequency Voltage Hz V A A

Power Supply

V1 1~ 50 0.18 0.18 3 50 220-230-240 0.18 0.18 3 0.18 0.18 3 50

Current

Cooling Nominal running current Heating (RLA) For Power Supply Quantity

Wiring connections

Split Sky Air Indoor Units

Indoor Units R-410A FTX-GV1B

3
3-1
FTX20-35GV

Dimensional drawing & centre of gravity


Dimensional drawing

3
Air flow (Indoor) Rear (Space for performance) Right Including mounting plate Front panel fixing screws ( Inside) 50Min. (Space for maintenance) General rating name plate Signal receiver Operation lamp Timer lamp Terminal block with earth terminal (Inside) Gas pipe 9,5 Cut (The length of pipe outside the unit: About 400) Liquid pipe 6,4 Cut (The length of pipe outside the unit: About 400) Signal transmitter Model name plate BLADE ANGLE Up/down (Automatic) Cooling Heating Dry Drain hose ( Connecting part I.D. 14 O.D. 16 The hose length of ouside the unit is about 450) 30Min.

The mark () shows piping direction

1
3

Left

REQUIRED SPACE

50Min. (Space for maintenance)

Bottom

Flaps

Indoor unit ON/OFF switch Room temp. thermistor (Inside)

Fan Right/left (Manual)

Wall hole for embedded piping 65 Hole STANDARD LOCATIONS OF WALL HOLES

Wall hole 65 Hole

INFRARED REMOTE CONTROL (ARC433A89) 3D058481

Split Sky Air Indoor Units

Indoor Units R-410A FTX-GV1B

3
3-2

Dimensional drawing & centre of gravity


Centre of gravity

FTX20-35GV

1
3

4D059099

Split Sky Air Indoor Units

Indoor Units R-410A FTX-GV1B

Piping diagram

FTX20-35GV INDOOR UNIT Heat exchanger

3
7.0 Cut 4.8 Cut

1
4
7.0 Cut 7.0 Cut

7.0 Cut

Thermistor on heat exch.

Cross flow fan Field piping (6.4Cut) Fan motor

Field piping (9.5Cut)

9.5 Cut

Refrigerant flow Cooling Heating 4D058926

Split Sky Air Indoor Units

Indoor Units R-410A FTX-GV1B

5
5-1

Wiring diagram
Wiring diagram

FTX20-35GV

1
5
RECTIFIER FIELD WIRING TRANSMISSION CIRCUIT OUTDOOR CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. SIGNAL RECEIVER

INDOOR INFRARED REMOTE CONTROL

NOTE
1 1. PCB3 is shows the case of option connection.
OPTION

: Frame ground : Fuse : Harness : Pilot lamp : Fan motor : Swing motor : Printed circuit board : Thermistor : Connector : Operation switch : Terminal strip : Protective earth

3D058454

Split Sky Air Indoor Units

Indoor Units R-410A FTX-GV1B

6
6-1
FTX20GV

Sound data
Sound pressure spectrum
COOLING Octave band sound pressure level dB(0dB=0.0002bar)

FTX20GV
Octave band sound pressure level dB(0dB=0.0002bar)

HEATING

3 1
6

Approximate threshold hearing for continuous noise

Approximate threshold hearing for continuous noise

Octave band center frequency (Hz)

Octave band center frequency (Hz)

3D058955

3D058955

NOTES
1 Operating conditons: 230V 50Hz : 50 Hz 230V (H) : 50 Hz 230V (L) Cooling Measure in anechoic room Location of microphone
1m

NOTES
1 Operating conditons: 230V 50Hz : 50 Hz 230V (H) : 50 Hz 230V (L) Heating Measure in anechoic room Location of microphone
1m

2 3

2 3

0.8m

Operation noise differs with operation and ambient conditions.

Operation noise differs with operation and ambient conditions.

FTX25GV
Octave band sound pressure level dB(0dB=0.0002bar)

COOLING

FTX25GV
Octave band sound pressure level dB(0dB=0.0002bar)

HEATING

Approximate threshold hearing for continuous noise

Approximate threshold hearing for continuous noise

Octave band center frequency (Hz)

0.8m Octave band center frequency (Hz)

3D058956

3D058956

NOTES
1 Operating conditons: 230V 50Hz : 50 Hz 230V (H) : 50 Hz 230V (L) Cooling Measure in anechoic room Location of microphone
1m

NOTES
1 Operating conditons: 230V 50Hz : 50 Hz 230V (H) : 50 Hz 230V (L) Heating Measure in anechoic room Location of microphone
1m

2 3

2 3

0.8m

Operation noise differs with operation and ambient conditions.

Operation noise differs with operation and ambient conditions.

Split Sky Air Indoor Units

0.8m

Indoor Units R-410A FTX-GV1B

6
6-1
FTX35GV

Sound data
Sound pressure spectrum
COOLING Octave band sound pressure level dB(0dB=0.0002bar)

FTX35GV
Octave band sound pressure level dB(0dB=0.0002bar)

HEATING

1
6

Approximate threshold hearing for continuous noise

Approximate threshold hearing for continuous noise

Octave band center frequency (Hz)

3D058957

Octave band center frequency (Hz)

3D058957

NOTES
1 Operating conditons: 230V 50Hz : 50 Hz 230V (H) : 50 Hz 230V (L) Cooling Measure in anechoic room Location of microphone
1m

NOTES
1 Operating conditons: 230V 50Hz : 50 Hz 230V (H) : 50 Hz 230V (L) Heating Measure in anechoic room Location of microphone
1m

2 3

2 3

0.8m

Operation noise differs with operation and ambient conditions.

Operation noise differs with operation and ambient conditions.

Split Sky Air Indoor Units

0.8m