0% found this document useful (0 votes)
731 views

Bracing Connection

This document provides a design calculation for a bracing connection between four structural members (Members 1-4) and a gusset plate. It includes layout drawings of the connection, required member strengths, material properties, and calculations to check the capacity of each member and connection. Key checks shown include: tension and shear capacity of welds, tension yielding and rupture of braces, tension yielding of Whitmore sections, block shear rupture capacity of the gusset plate, and buckling of the gusset plate. Forces in the gusset plate connecting it to the column are also calculated.

Uploaded by

rajedmaglinte
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
731 views

Bracing Connection

This document provides a design calculation for a bracing connection between four structural members (Members 1-4) and a gusset plate. It includes layout drawings of the connection, required member strengths, material properties, and calculations to check the capacity of each member and connection. Key checks shown include: tension and shear capacity of welds, tension yielding and rupture of braces, tension yielding of Whitmore sections, block shear rupture capacity of the gusset plate, and buckling of the gusset plate. Forces in the gusset plate connecting it to the column are also calculated.

Uploaded by

rajedmaglinte
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

Design Calculation for Bracing Connection - Joint SWF-SF11

1.) LAYOUT

Typ

3/16" 3/16" 3/16" 3/16"

8" 8" 4" 4"

HSS8X8X1/4

Typ

3
8.0

3/16" 3/16"

4" Typ 4"

HSS8X4X1/8

HSS8X4X1/8

1
PL 0.375 - A36

4.0 10" 9"

4.0 3/16" 3/16"

HSS8X8X1/2

5
5" 1'-3 1/2'' 1'-1 1/2" 5"

11 11/16" 9" Typ 3/16" 3/16" 8" 8"

10 3/16" 10"

HSS8X8X1/4 8.0 10"

PL 0.375 - A36

2.)

REQUIRED STRENGTHS: Member 1: Axial Load, Ta Axial Load, Ca Member 2: Axial Load, Ta Axial Load, Ca Member 3: Axial Load, Ta Axial Load, Ca Member 4: Axial Load, Ta Axial Load, Ca

= =

5.0 5.0

kips (Tension) kips (Compression)

= =

5.0 5.0

kips (Tension) kips (Compression)

= =

25.0 25.0

kips (Tension) kips (Compression)

= =

20.0 20.0

kips (Tension) kips (Compression)

3.)

MATERIAL & GEOMETRIC PROPERTIES:

Page 1 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Member 1: Size: Fy Fu B HT A t Member 2: Size: Fy Fu B HT A t Member 3: Size: Fy Fu B HT A t Member 4: Size: Fy Fu B HT A t Member 5: Size: Fy Fu B HT A t HSS8X4X1/8 = 46 = 58 4.00 = 8.00 = 2.70 = 0.116 = ASTM A500 Gr. B ksi ksi in in in in

HSS8X4X1/8 = 46 = 58 4.00 = 8.00 = 2.70 = 0.116 =

ASTM A500 Gr. B ksi ksi in in in in

HSS8X8X1/4 = 46 = 58 8.00 = 8.00 = 7.10 = 0.233 =

ASTM A500 Gr. B ksi ksi in in in in

HSS8X8X1/4 = 46 = 58 8.00 = 8.00 = 7.10 = 0.233 =

ASTM A500 Gr. B ksi ksi in in in in

HSS8X8X1/2 = 46 = 58 8.00 = 8.00 = 13.50 = 0.465 =

ASTM A500 Gr. B ksi ksi in in in in ASTM 36 ksi ksi in

Gusset Plate: Fy = Fu = tgusset =

36 58 3/8

4.)

BRACE CONNECTION MEMBER 1: Brace to Gusset Plate Weld:

Page 2 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Electrode Class Fu Fv = = = = = = = = = = = = = = = = = E700XX

Nominal Tensile Strength of Weld 70.00 Ksi Allowable Weld Shear Strength 0.6 Fu / 2 21.00 Ksi Size of Weld 0.1875 in. (Use 0.1250 in. for calculation)

w Pw

Shear Capacity of 1/8" weld per Linear Inch 0.707 * Fv * w (0.707 * 21 * 0.125) 1.856 Kips/in Length of Weld 4.00 in. Weld Shear Capacity Pw * 4 L2 29.694 Kips

L1 Vw

Vw

>

5.00

Kips

(OK)

Tension Yielding of the Brace: Rn/ = = = Capacity from 'Limit State of Tension Yielding of Brace' Fyb * Ag1 1.67 5.00 kips (OK) 74.37 kips >

Tension Rupture of the Brace: Rn/ Capacity from 'Limit State of Tension Rupture of Brace' Fub * Ae = 2.00 where: = (Length of Weld in HSS) 4.00 in L B H x U An Ae = = = = = = = = = = 8.00 4.00 in in (Width of HSS Section) (Height of HSS Section) =

(B2 + 2 * B * H) / (4 * (B + H)) 2.667 in 1 - (x / L) 0.333 Ag1 - 2 * (tp + 0.0625) * t1 2.599 in U * An 0.866 in

Page 3 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Rn/ = 25.12 kips > 5.00 kips (OK)

Whtimore Section L= L= 2 lw tan 30 + B 8.619 in 0.000 1.580 in in = 1.67 B= 4.00 in

Whitmore width in Vertical Member = Whitmore width in Horizontal Member =

Check tension yielding on the Whitmore section Rn = Fy Aw Rn = 36 x [ ( 8.619 - 0 - 1.58 ) x 0.375 ] Rn = Rn/ 95.02 = kips 56.90 kips > 5.00

kips

(OK)

Check block shear rupture of the gusset Rn = = Nominal Block Shear Strength of Gusset ( =2)

2 x Min[ (0.6 x Fu x Anv + Ubs x Fu x Ant); (0.6 x Fy x Agv + Ubs x Fu x Ant) ] Where: Ubs = 1.0 Ant = Net Area with Tension Resistance = Bbrace x tgusset = 1.50 in
2

Agv = Gross Area with Shear Resistance = 2 x lw x tgusset = 3.00 in


2

Anv = Net Area with Shear Resistance = Rn/ = 3.00 75.90 in


2

kips

>

5.00

kips

(OK)

Plate Buckling of Connection Plate Ap = = = = = Effective Plate Cross-sectional Area L*t 3.232 in Plate Unbraced Length of Whitmore Section 4.65 in.

Lcr

Page 4 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


K = = = = = = Effective Length Factor 1.200 Radius of Gyration t / 3.464 0.108 in. 51.544 > 25

K Lcr/r

From Specification E3 Fe = = Fcr = ()*E/(KL/r) ksi 107.73

>

0.44*Fy = 15.84 ksi

[0.658^(Fy/Fe)]*Fy ksi 31.30 Allowable Strength in Compression Ap * Fcr 1.67 60.58 kips > 5.00 kips (OK)

Rn/

= =

= MEMBER 2:

Brace to Gusset Plate Weld: Electrode Class Fu = = = = = = = = = = = = = = = = = E700XX

Nominal Tensile Strength of Weld 70.00 Ksi Allowable Weld Shear Strength 0.6 Fu / 2 Ksi 21.00 Size of Weld 0.1875 in.

Fv

(Use

0.1250 in. for calculation)

Pw

Shear Capacity of 1/8" weld per Linear Inch 0.707 * Fv * w (0.707 * 21 * 0.125) 1.856 Kips/in Length of Weld in. 4.00 Weld Shear Capacity Pw * 4 L2 29.694 Kips

L1 Vw

Vw

>

5.00

Kips

(OK)

Tension Yielding of the Brace:

Page 5 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Rn/ = = = Capacity from 'Limit State of Tension Yielding of Brace' Fyb * Ag2 1.67 74.37 kips > 5.00 kips (OK)

Tension Rupture of the Brace: Rn/ Capacity from 'Limit State of Tension Rupture of Brace' Fub * Ae = 2.00 where: L = 4.00 in (Length of Weld in HSS) B H x = = = = = = = = = = 8.00 4.00 in in (Width of HSS Section) (Height of HSS Section) =

2 (B + 2 * B * H) / (4 * (B + H)) 2.667 in

1 - (x / L) 0.333 Ag2 - 2 * (tp + 0.0625) * t2 2.599 in U * An 0.866 25.12 kips

An

Ae

in > 5.00 kips (OK)

Rn/

Whtimore Section L= L= 2 lw tan 30 + B 8.619 in 0.000 1.670 in in = 1.67 B= 4.00 in

Whitmore width in Vertical Member = Whitmore width in Horizontal Member =

Check tension yielding on the Whitmore section Rn = Fy Aw Rn = 36 x [ ( 8.619 - 0 - 1.67 ) x 0.375 ] Rn = Rn/ 93.81 = kips 56.17 kips > 5.00

kips

(OK)

Check block shear rupture of the gusset

Page 6 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Rn = = Nominal Block Shear Strength of Gusset ( =2) 2 x Min[ (0.6 x Fu x Anv + Ubs x Fu x Ant); (0.6 x Fy x Agv + Ubs x Fu x Ant) ] Where: Ubs = 1.0 Ant = Net Area with Tension Resistance = Bbrace x tgusset = 1.50 in
2

Agv = Gross Area with Shear Resistance = 2 x lw x tgusset = 3.00 in


2

Anv = Net Area with Shear Resistance = Rn/ = 3.00 75.90 in


2

kips

>

5.00

kips

(OK)

Plate Buckling of Gusset Plate Ap = = = = = = = = = = = Effective Plate Cross-sectional Area L*t 3.232 in Plate Unbraced Length of Whitmore Section 3.95 in. Effective Length Factor 1.200 Radius of Gyration t / 3.464 0.108 in. 43.785 > 25

Lcr

K Lcr/r

From Specification E3 Fe = = Fcr = ()*E/(KL/r) 149.30 ksi

>

0.44*Fy = 15.84 ksi

[0.658^(Fy/Fe)]*Fy 32.54 ksi Allowable Strength in Compression Ap * Fcr 1.67 62.98 kips > 5.00 kips (OK)

Rn/

= =

= MEMBER 3:

Page 7 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Brace to Gusset Plate Weld: Electrode Class Fu = = = = = = = = = = = = = = = = = E700XX

Nominal Tensile Strength of Weld 70.00 Ksi Allowable Weld Shear Strength 0.6 Fu / 2 21.00 Ksi Size of Weld 0.1875 in.

Fv

(Use

0.1250 in. for calculation)

Pw

Shear Capacity of 1/8" weld per Linear Inch 0.707 * Fv * w (0.707 * 21 * 0.125) 1.856 Kips/in Length of Weld 8.00 in. Weld Shear Capacity Pw * 4 L2 59.388 Kips

L1 Vw

Vw

>

25.00

Kips

(OK)

Tension Yielding of the Brace: Rn/ = = = Capacity from 'Limit State of Tension Yielding of Brace' Fyb * Ag3 1.67 195.57 kips > 25.00 kips (OK)

Tension Rupture of the Brace: Rn/ Capacity from 'Limit State of Tension Rupture of Brace' Fub * Ae = 2.00 where: 8.00 in L = (Length of Weld in HSS) B H x = = = = = = 8.00 8.00 in in (Width of HSS Section) (Height of HSS Section) =

2 (B + 2 * B * H) / (4 * (B + H)) 3.000 in

1 - (x / L) 0.625

Page 8 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


An = = = = Ag3 - 2 * (tp + 0.0625) * t3 in 6.896 U * An 4.310 124.99 kips

Ae

in > 25.00 kips (OK)

Rn/

Whtimore Section L= L= 2 lw tan 30 + B 17.238 in 0.000 0.000 in in = 1.67 B= 8.00 in

Whitmore width in Vertical Member = Whitmore width in Horizontal Member =

Check tension yielding on the Whitmore section Rn = Fy Aw Rn = 36 x [ ( 17.238 - 0 - 0 ) x 0.375 ] Rn = Rn/ 232.71 = kips kips > 25.00

139.35

kips

(OK)

Check block shear rupture of the gusset Rn = = Nominal Block Shear Strength of Gusset ( =2)

2 x Min[ (0.6 x Fu x Anv + Ubs x Fu x Ant); (0.6 x Fy x Agv + Ubs x Fu x Ant) ] Where: Ubs = 1.0 Ant = Net Area with Tension Resistance = Bbrace x tgusset = 3.00 in
2

Agv = Gross Area with Shear Resistance = 2 x lw x tgusset = 6.00 in


2

Anv = Net Area with Shear Resistance = Rn/ = 6.00 151.80 in


2

kips

>

25.00

kips

(OK)

Plate Buckling of Gusset Plate Ap = Effective Plate Cross-sectional Area


Page 9 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


= = Lcr = = = = = = = = L*t 6.464 in

Plate Unbraced Length of Whitmore Section 1.00 in. Effective Length Factor 1.200 Radius of Gyration t / 3.464 0.108 in. 11.085 < 36 25 ksi

K Lcr/r

Thus Fcr = Fy = Rn/ = =

Allowable Strength in Compression Ap * Fcr 1.67 139.35 kips > 25.00 kips (OK)

Gusset Plate to Colum:

C1 e1

T3 e2 T3

T2

A C1H

C1v

T2v T2H

L1

L2

Solving for component forces: C1H = = C1V = = 5 (1.44) [ (1) + (1.44) ] 4.1 kips

5 (1) [ (1) + (1.44) ] 2.9 kips

Page 10 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


T2H = = T2V = = T3 e1 e2 L1 L2 L L = 5 (1.2) [ (1) + (1.2) ] 3.8 kips

5 (1) [ (1) + (1.2) ] 3.2 25.0 kips kips

= = = = = = L1

5.77 4.79 15.5 13.5 + L2 29.0

in in in in

in

The normal stress is, ft = P/L + 3M/L

The in-plane stress is, fv = V/L

Consider section A-A P = = = = T3 + T2V - C1V 25.3 kips C1V x e1 kip-in 16.5

then, ft and, V

0.933

kip/in

= = =

C1H 7.9

T2H kips kip/in

fv

0.274

The resultant is, f = = [ (0.933) + (0.274) ] 0.972 kip/in

Check weld size Fv = Allowable Weld Shear Strength


Page 11 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


= = = = = w = = = = = = = 0.6 Fexx / 2 Ksi 21.00 tan 0.274 0.933 16.3734 deg rad 0.286 [ Fexx = 70ksi]

Size of Weld in. 0.1875

(Use

0.1250 in.

for calculation)

Pw

Shear Capacity of 1/8" weld per Linear Inch 0.707 * Fv * w * (1.0 + 0.50 sin1.5) (0.707 * 21 * 0.125) * (1.075) 1.995 Kips/in 3.990 Kips/in > 0.97 Kips/in (OK)

2 Pw

Check plate stress fa = fa = fv = fv = ft tgusset 2.487 fv tgusset 0.731 = ksi = ksi < 0.93 0.375 < 0.27 0.38
0.6Fy/ = Fy/ =

( = 1.67) 22 ksi ( = 1.5) 14 ksi (OK) (OK)

Check HSS wall Force component perpendicular to HSS wall Ft = ft x L = 27.05 kips

HSS wall capacity Rn/ = [ Fy t2 / (1- tp/B)] [ (2N/B + 4(1 -tp/B)0.5 ) Qf] Fy t tp B N Qf Rn/ MEMBER 4: Brace to Gusset Plate Weld: = = = = = = = 46 0.465 3/8 8.00 29.0 1 kips > 27.05 kips (OK) ( = 1.5)

where:

77.6063

Page 12 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Electrode Class Fu = = = = = = = = = = = = = = = = = E700XX Nominal Tensile Strength of Weld 70.00 Ksi Allowable Weld Shear Strength 0.6 Fu / 2 21.00 Ksi Size of Weld 0.1875 in.

Fv

(Use

0.125 in.

for calculation)

Pw

Shear Capacity of 1/8" weld per Linear Inch 0.707 * Fv * w (0.707 * 21 * 0.125) 1.856 Kips/in Length of Weld 8.00 in. Weld Shear Capacity Pw * 4 L2 59.388 Kips

L1 Vw

Vw

>

20.00

Kips

(OK)

Tension Yielding of the Brace: Rn/ = = = Capacity from 'Limit State of Tension Yielding of Brace' Fyb * Ag4 1.67 195.57 kips > 20.00 kips (OK)

Tension Rupture of the Brace: Rn/ Capacity from 'Limit State of Tension Rupture of Brace' Fub * Ae = 2.00 where: 8.00 in L = (Length of Weld in HSS) B H x = = = = = = = = 8.00 8.00 in in (Width of HSS Section) (Height of HSS Section) =

(B2 + 2 * B * H) / (4 * (B + H)) 3.000 in 1 - (x / L) 0.625 Ag4 - 2 * (tp + 0.0625) * t4 6.896 in

An

Page 13 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


Ae = = U * An 4.310 124.99 kips in > 20.00 kips (OK)

Rn/

Whtimore Section L= L= Width of Whitmore Section Minimum[ (2 x 8.00 tan 30 + 8) , 10 ] 10.000 in = 1.67

Check tension yielding on the Whitmore section Rn = Fy Aw Rn = 36 x [10 x 0.375 ] Rn = Rn/ 135.00 = kips kips > 20.00

80.84

kips

(OK)

Check block shear rupture of the gusset Rn = = Nominal Block Shear Strength of Gusset ( =2)

2 x Min[ (0.6 x Fu x Anv + Ubs x Fu x Ant); (0.6 x Fy x Agv + Ubs x Fu x Ant) ] Where: Ubs = 1.0 Ant = Net Area with Tension Resistance = Bbrace x tgusset = 3.00 in
2

Agv = Gross Area with Shear Resistance = 2 x lw x tgusset = 6.00 in


2

Anv = Net Area with Shear Resistance = Rn/ = 6.00 151.80 in


2

kips

>

20.00

kips

(OK)

Plate Buckling of Gusset Plate Ap = = = = = Effective Plate Cross-sectional Area L*t 3.750 in Plate Unbraced Length of Whitmore Section 1.00 in.

Lcr

Page 14 of 15

Design Calculation for Bracing Connection - Joint SWF-SF11


K = = = = = = Effective Length Factor 1.200 Radius of Gyration t / 3.464 0.108 in. 11.085 < 36 25 ksi

K Lcr/r

Thus Fcr = Fy = Rn/ = =

Allowable Strength in Compression Ap * Fcr 1.67 80.84 kips > 20.00 kips (OK)

HSS wall capacity Rn/ = [ Fy t2 / (1- tp/B)] [ (2N/B + 4(1 -tp/B)0.5 ) Qf] Fy t tp B N Qf Rn/ = = = = = = = 46 0.465 3/8 8.00 10.0 1 kips > 20.00 kips (OK) ( = 1.5)

where:

44.5605

Page 15 of 15