Broadcrown Ltd, Airfield Industrial Estate, Hixon, Stafford. ST18 0PF UK Tel: +44 (0)1889 272200 Fax: +44 (0)1889 272220 www.broadcrown.com November 2009

John Deere 4024 TF220

Newage Stamford BCI 184

Generator Model:

BCJD 23-50

50 Hz

3-Phase

Power Factor

Cos = 0.8
STANDBY POWER (LTP)
kVA 18 22.5 22.5 kWe 14 18 18 Amps 24 31 34

RATINGS Voltage 440/254 415/240 380/220

PRIME POWER (PRP)


kVA 18 22.5 22.5 kWe 14 18 18

Definition of Ratings & Reference Conditions


Prime Power (PRP) is the nominal output continuously available, where the average load (variable) does not exceed 70% of the prime power rating. 10% overload is available for a maximum of 1 hour in 12 hours of operation. Standby Power (LTP) is the maximum output available, for up to 500 hours per year, where the average load (variable) does not exceed 70% of the standby power rating. No overload is available. Standard Reference Conditions: air temperature 25C (77F), barometric pressure 99kPa, [110m(361ft) altitude], 30% relative humidity. Note: The above ratings may be subject to derate at different operating conditions. Please see the Derate Guidelines on the Broadcrown Website. All power ratings and reference conditions in accordance with ISO 8528-1 and ISO 3046-1.

Key Features:
Efficient water cooled Diesel engine. Single bearing Newage Stamford alternator Radiator with pressure cap and drain point Fully guarded engine-driven fan Fabricated steel skid base with fork lift pockets Moulded polypropylene fuel tank with filler cap Heavy duty rubber anti-vibration mountings 12V starter battery and connecting cables Separate engine-driven battery charging alternator Spin on oil and fuel filters and dry type air filter element Industrial silencer (15dBA reduction) supplied loose BC 701E-M Key Start control system Main line circuit breaker Factory Test Certificate Operation & Maintenance Manual Wide range of optional extra features available

Overall Dimensions & Weights - Open Set

Length (L) = 1640mm Width (W) = 670mm Height (H) = 1335mm Dry Weight (inc oil) = 615kg Operating Weight = 715kg

Typical Open Generator Noise Level at 1m, Free Field (dB)


Overall dBA 92 63 Hz 79 125 Hz 81 250 Hz 84 500 Hz 87 1000 Hz 88 2000 Hz 84 4000 Hz 78 8000 Hz 76

All designs and specifications subject to change without notice

BCJD 23-50
November 2009

ENGINE & COOLING SYSTEM


SI Units Engine Speed Gross Power Fan Power Net Power Emissions Certification Altitude Capability Cylinders / Type Aspiration / Charge Cooling Governing / Engine Management Bore / Stroke Cubic Capacity BMEP Fuel Consumption at 100% Power Fuel Consumption at 75% Power Fuel Consumption at 50% Power Total fuel flow Standard Fuel Tank Capacity Engine Air Flow Maximum Air Intake Restriction (used filter) Exhaust Gas Flow Exhaust Gas Temperature Maximum Exhaust Back Pressure Typical Exhaust Pipe Diameter Radiator Cooling Air Flow Max Restriction to Cooling Air Flow Max Radiator Air-On Temperature Maximum Coolant Temperature Coolant Capacity - Engine Only Total Coolant Capacity Total Oil Capacity incl Filters Typical Oil Pressure at Rated Speed Typical Oil Consumption (>250hrs Operation) Heat Rejection to Engine Cooling Water Heat Rejection to Charge Cooler Heat Radiated From Engine (Typical) Electrical System Voltage Battery Type Battery Capacity SAE CCA r/min kWm kWm kWm m

JOHN DEERE 4024 TF220


PRIME
1500 22 1.0 21 3048 4 cyl / inline / 4-stroke Turbocharged / None Electronic Governor 86 / 105 2.4 721 5.7 6.4 2.9 83 85 0.028 6.25 0.073 460 7.5 40 0.8 260 50 105 2.6 20.0 20.0 241 0.02 14 n/a 2.8 12 1 x 069 520 3.0 15 238 0.078 480 0.030 787 6.5 4.8 3.3 3048 24 1.0 23

STANDBY

General

Performance

mm litres kPa litres/h litres/h litres/h litres/h litres m/s kPa m/s C kPa mm m/s Pa C C litres litres litres kPa litres/h kW kW kW V A

Elec

Thermal

Oil

Cooling

Exhaust

Air

Fuel

ALTERNATOR
SI Units Manufacturer Model (may vary with voltage) Operating Temperature Coupling / No. of Bearings Phase / Poles / Winding Type Power Factor Excitation Insulation System AVR Type Voltage Regulation

NEWAGE STAMFORD BCI 184


PRIME STANDBY

NEWAGE STAMFORD BCI 184 E BCI 184 E 40 27 Direct / Single Bearing 3-Phase / 4-Pole / Winding 311 Cos = 0.8 Self Excited Class H SX 460 1.0%
All designs and specifications subject to change without notice

General Data

BCJD 23-50
November 2009

STANDARD CONTROL SYSTEM


The standard control system for the Midi Range is BC701E-M (photo), based on the Deep Sea Electronics DSE701 Key Start controller. This provides for the manual control of the generator via a two-position key switch and membrane push button for Start, together with Overspeed, Low Oil Pressure and High Coolant Temperature protection. LED indications for protection operation LED indication for charge alternator fail Membrane push button for engine preheat (where applicable) Analogue voltmeter with 4-position selector switch Analogue ammeter with 4-position selector switch Engine hours counter Emergency Stop button One auxillary input for optional features Optional - Generator Running volt-free output

BC 701E-M Key Start

The panel is constructed in 1.5mm steel, powder coated to RAL9001 for a high quality, durable finish with the hinge points of the cover located at the bottom edge for improved maintenance access.

CONTROL SYSTEM OPTIONS


The optional BC701-M control system (not illustrated) is similar to the standard unit but benefits from the addition of : Analogue frequency meter Analogue gauges for Oil Pressure, Coolant Temperature & Battery Charge Amps 7-Position voltmeter selector switch The BC704E-M Auto-Start control system (photo) features the DSE704 control module which provides for automatic remote start. Additional features include : Underspeed protection Fail to Start indication Automatic cool-down timer function Optional - Common Alarm & System In Auto volt-free contacts

The BC704-M system (not illustrated) is again similar, but with the addition of analogue engine instruments and frequency meter.

As a digital alternative, there is the BC5110-M Auto Start system, based on the DSE5110 control module. This provides all the functionality of the BC704-M system but with digital displays for : Coolant Temperature, with integral high temperature protection Oil Pressure, with integral low pressure protection Volts, Amps and Frequency Engine operating hours

This system also has an increased digital input/output count for external options and, being cost effective in comparison with the analogue system, is now the preferred choice for most customers. With a modest cost saving, the BC5110E-M is similar to the BC5110-M but comes without the digital indications for Oil Pressure and Coolant Temperature. The protection facilities are still provided however..

Finally, the BC5310-M system (just the DSE 5310 module shown here) provides complete power monitoring and protection facilities. Compared to BC5110-M, addition features include : Pre-alarms for Low Oil Pressure and High Coolant Temperature Digital display of kW, kVA and Power Factor Under/Over Volts protection Over Current Protection Full RS485 Telemetry implementation
All designs and specifications subject to change without notice

BCJD 23-50
November 2009

OPTIONAL ACOUSTIC ENCLOSURE

Midi Canopy M2

The optional acoustic enclosure for this model is the Midi 2 Canopy, suitable for operation in harsh outdoor environmments whilst providing excellent security and acoustic performance. All steel canopy components are pre-treated and polyester powder coated (to a typical thickness of 70-80m) in RAL9001 white and the baseframe is finished in RAL9005 black. Acoustically, the canopy is designed to meet the requirements of EU Legislation 2000/14/EC, achieved by extensive use of fire-retardant polyurethane foam together with efficient management of cooling air. Exhaust noise is minimised by internally mounted high performance exhaust silencers. A steel fuel tank with filler, gauge and accessory points, is integrated within the baseframe. Other key features include : Side-opening doors for good service access Panel viewing window in main door Heavy duty locks on all doors for total security Weather cap on exhaust discharge Emergency Stop button relocated to canopy exterior Lifting and holding down points Fork Lift pockets Optional single roof lifting point.

Dimensions (mm) L x W x H

Additional Weight (kg)

Typical Sound Pressure Level at 75% of Prime Power dB(A) at 1m dB(A) at 7m

Fuel Tank Capacity (Litres) Integral Bunded

Single Point Lift Optional

2100 x

850

x 1240

195

74

64

95

Indicative weight of canopy additional to open set Typical SPL is a mean level, measured in free field conditions, with no contributory background noise.

KEY MECHANICAL OPTIONS (Open Set)


Engine & Cooling : - Electronic governor - Oil and coolants drains extended to edge of baseframe - Coolant heater Alternator : - Anti-condensation heater - Quadrature droop kit - Alternative AVR Please refer to Broadcrown Sales Department for full details of these and other options Fuel System : - Low fuel level switch (single point) - Fuel level switch (four point)

All designs and specifications subject to change without notice broadcrown.com