Combustible Gas Controller
Combustible Gas Controller
Features:
1. Advanced MPU technology 2. Max. capacity of system: 128 channels 3. Work in patrol type 4. Four BUS signal outputs: Positive Terminal, Negative Terminal, Communication Line LA, Communication Line LB 5. Real-time gas concentration display 6. Bright LCD display, touch pad keyboard 7. Real-time clock, works continuously even out of power 8. The function of Black Box can store old alarm reports. It can keep working even no power 9. Main source and back-up power exchange automatically to support power to back-up battery 10. Accidental alarm report is in preference to device faulty indicator
CA-2100
11. Should use with our fixed probe (CA-217A-B) 12. RS485 Industrial field BUS with lightning protection 13. Printer output can print out alarm / fault information of system 14. CA-2100 PLUS is the enhanced model of CA-2100
Specifications
Working Method: Automatic Patrol Output Voltage: DC24V5A (Supply Power to The Probe #CA-217A-B) Communication Interface: RS485 Working Voltage: AC220V/50Hz Transmission Distance: <1000 m Alarming Function: Multi-level Alarm Sample Rate: <8 Channels/Second Max. Capacity of System: 128 Channels Display Method: Concentration Display, Specific Passage Display Alarming Passage Takes Priority Display Error: <+-5% Working Environment: Tem-10%~+50% RH 30%-95% Display Function: LCD Display Printing Output: Optional Back-up Power System: 2 DC12V2.3AH Controller Output: Switch Signal (Binary Signal) Weight: About 10kg Controller Size: 500mm(Length)*350mm(Width)*110(Thickness)mm Performance Standards: GB16808-1997/GB16808-2008
Features:
1. Adopt advanced imported catalytic combustion sensor 2. Reliable, sensitive and long performance life 3. High resistance to poison, good disturb-proof against temperature and humidity 4. Automatic zero calibration can avoid long-term zero drift caused by measurement error 5. Concentration signal output 6. Over-current protection, Anti-polarity protection 7. RS485 communication interface can use with our CA-2100 series of controllers 8. Scope of working voltage: DC10V~DC30V 9. CA-217A PLUS is the enhanced model of CA-217A-B
CA-217A-B
Specifications
Detection Principle: Catalytic Combustion Detection Method: Diffused Applicable Gas: Combustible Gases Working Method: Continuous Working Detection Scope: 0~100%LEL Respond Time: <=15S Detection Error: <+-3%LEL Environment Temperature: -40~+70 Relative Humidity: 30%-95% Output Signal: Concentration Digital Signal Working Voltage: DC10V~DC30V Sensor Life Span: 3 Years Transmission Distance: <1000m Operation Pressure: (86-106) kPa Features: Detector Size: 158*130*93mm MPU technology Explosion-proof Level: 1. Advanced Exd II CT6 2. Max. capacity of system: 4 channels Connection Thread : 1/2G Inner Thread 3. Work in patrol type Weight: 1kg BUS signal outputs: 4. Four Communication: RS485 PositiveTerminal,NegativeTerminal, Performance Standards: Communication GB3836.1-2000 Line LA, GB3836.2-2000 Communication GB15322.1-2003 Line LB
CA-2100D
5. Four-passage concentration real-time dislay 6. Bright LCD display 7. Real-time clock, works continuously even out of power 8. Accidental alarm report is in preference to device faulty indicator 9. Should use with our fixed probe (CA-217A-B) Combustible Gas Controller (BUS-Type) 10. RS485 Industrial field BUS with lightning protection
CA-2100D
Specifications
Working Method: Automatic Patrol DC24V@1A (Supply Power to The Probe #CA-217A-B) Output Voltage: Communication Interface: RS485 Working Voltage: AC220V/50Hz Transmission Distance: <1000 m Alarming Function: 2 Level Output Sample Rate: <4 Channels/Second Max. Capacity of System: 4 Channels Display Method: Four-passage Concentration Real-time Dislay Display Error: <+-5% Working Environment: Tem-10%~+50% RH 30%-95% Weight: About 3kg Controller Size: 350mm(Length)*230mm(Width)*80(Thickness)mm Performance Standards: GB16808-1997/GB16808-2008 Features:
1. Advanced MPU technology 2. Max. capacity of system: 16 channels 3. Work in patrol type 4. Four BUS signal outputs: PositiveTerminal,NegativeTerminal, Communication Line LA, Communication Line LB 5. Real-time concentration dislay circularly 6. Bright LCD display, touch pad keyboard 7. Real-time clock, works continuously even out of power 8. Accidental alarm report is in preference to device faulty indicator 9. Should use with our fixed probe (CA-217A-B) Combustible Gas Ccontroller (BUS-Type) 10. RS485 Industrial field BUS with lightning protection
CA-2100E
CA-2100E
Specifications
Working Method: Automatic Patrol DC24V@3A (Supply Power to The Probe #CA-217A-B) Output Voltage: Communication Interface: RS485 Working Voltage: AC220V/50Hz Transmission Distance: <1000 m Alarming Function: 2 Level Output Sample Rate: <8 Channels/Second Max. Capacity of System: 16 Channels Concentration Display, Specific Passage Display Display Method:
Alarming Passage Takes Priority
Features:
1. Advanced MPU technology 2. Max. capacity of system: 2 channels 3. Work in patrol type 4.Standard transmission signal of 4-20mA: PositiveTerminal,NegativeTerminal, Signal Line IO 5. Three digitals display gas concentration ; four digitals display time. 6. Alarm Function: 2 level output; Low Limit Alarm: 10%-25%LEL (adjustable) ; High Limit Alarm: 26%-99%LEL (adjustable) 7. Real-time clock, works continuously even out of power 8. Zero adjustable function 9. Should use with our fixed probe (CA-217A-D)
CA-2100A
Specifications
Working Method: Automatic Patrol DC24V@500mA (Supply Power to The Probe #CA-217A-B) Output Voltage: Communication Interface: 4-20mA Standard Signal Working Voltage: AC220V/50Hz Transmission Distance: <=1000 m Alarming Function: 2 Level Output Sample Rate: <4 Channels/Second Max. Capacity of System: 2 Channels Display Method: Digital Tube Display rotationally Display Error: <+-5% Working Environment: Tem-10%~+50% RH 30%-95% Display Function: LCD Display Weight: About 2.5kg Features: Controller Size: 290mm*210mm*85mm 1. Adopt advanced imported catalytic combustion sensor Connection Thread : 1/2G Inner Thread and long performance life 2. Reliable, sensitive High resistance to poison, good disturb-proof against Performance Standards:3. GB16808-1997 / GB16808-2008 temperature and humidity 4. Automatic zero calibration can avoid long-term zero drift caused by measurement error 5. Concentration signal output 6. Over-current protection, Anti-polarity protection 7. 4-20mA communication interface can use with our CA-217A-D Fixed Combustible Gas Detector/ Probe CA-2100A or CA-2100F controllers 8. Scope of working voltage: DC20V~DC30V
CA-217A-D
Specifications
Detection Principle: Catalytic Combustion Detection Method: Diffused Applicable Gas: Combustible Gases Working Method: Continuous Working Detection Scope: 0~100%LEL Respond Time: <=30S Detection Error: <+-3%LEL Environment Temperature: -40~+70 Relative Humidity: 30%-95% Output Signal: Concentration Digital Signal Working Voltage: DC20V~DC30V Sensor Life Span: 3 Years Transmission Distance: <=1000m Operation Pressure: (86-106) kPa Detector Size: 158*130*93mm Explosion-proof Level: Exd II CT6 Connection Thread : 1/2G Inner Thread Weight: 1kg Communication: 4-20mA Standard Current Performance Standards: GB3836.1-2000GB3836.2-2000GB15322.1-2003
Features:
Controller (TrayMounted 2. Max. capacity of system: 2 channels Type) CA-2100C Combustible Gas Alarm
3. Work in patrol type 4.Standard transmission signal of 4-20mA: PositiveTerminal,NegativeTerminal, Signal Line IO 5. Four groups of 8-segment LCD display the gas concentration 1. Advanced MPU technology
CA-2100C 6. Two levels alarming: The first level: 15%LEL (adjustable 10%-25%); the second level: 50 %LEL ( adjustable 26%-99% 7. Each level alarming output relay switch signal dependently 8. Every alarming output DC24V pulse signal 9. Able to return to zero, 10. Should use with our fixed probe (CA-217A-D)
Specifications
Working Method: Automatic Patrol DC12V@500mA (Supply Power to The Probe #CA-217A-B) Output Voltage: Communication Interface: 4-20mA Standard Signal Working Voltage: AC220V/50Hz Transmission Distance: <=1000 m Alarming Function: 2 Level Output Sample Rate: <4 Channels/Second Max. Capacity of System: 2 Channels Display Method: Digital Tube Display rotationally Display Error: <+-5% Features: Working Environment: Tem-10%~+50% RH 30%-95% 1. Advanced MPU technology Weight: About 1.5kg 2. Low power consumption Controller Size: 260mm*80mm*160mm 3. Sensitive and able to reture to zero Performance Standards: GB16808-1997 /GB16808-2008 self-repair 4. Full-function self-test and 5. Battery voltage low alarm 6. Alarm point is adjustable 1%-50%LEL
Specifications
Detection Scope: Protection Level:: Display Mold: Work Environment 0%~100%LEL IP54 Digital Tem:-20 ~+60 Hum<95 %
RH(Non-condensing) Power Supply Weight Re-Charge Time Detector Dimension Working Time DC4.8V Ni-MH Battery 2300 mAh About 350g 8h~10h 1. Adopt imported catalytic combustion sensor 520mmX80mmX38mm Features:
2. Able to detect combustible gases under high temperature condition
5. Automatic zero calibration can avoid long-term zero drift caused by measurement error 6. Concentration signal output 7. Over-current protection, anti-polarity protection Combustible Gas Detector/ Probe 8. 4-20mA standard AC or concentration digital output , able to work with our gas controller CA-2100A or CA- 2100F 9. Power supply range: DC20V~DC30V
CA-217A-K(DGW)
Specifications
Detection Principle: Catalytic Combustion Detection Method: Diffused Applicable Gas: Combustible Gases Working Method: Continuous Working Detection Scope: 0~100%LEL Respond Time: <=30S Detection Error: <+-3%LEL Environment Temperature: -30~+220 (Sensor) Relative Humidity: 30%-95% Concentration Digital Signal / Electric Current Loop Signal Output Signal: Working Voltage: DC20V~DC30V Sensor Life Span: 2 Years (under normal circumstances) Transmission Distance: <=1000m Operation Pressure: (86-106) kPa Detector Size: 158*130*93mm Explosion-proof Level: Exd II CT6 Connection Thread : 1/2G Inner Thread Weight: 1kg Communication: 4-20mA StandardFeatures: Current 1.Detection Gas: manufactured gas (hydrogen), Performance Standards: GB3836.1-2000 GB3836.2-2000 GB15322.1-2003
CA-386D-D2J Combustible
natural gas, liquefied petroleum gas (LPG) 2. Excellent sensor, stable and long-life, excellent oil smoke resistant performance Gas Detector With Robot Hand 3. Alarm Output: sound light alarm, net-work signal , robot hand signal output 4. Strong torsional force, capable of switching off solenoid valve automatically or manually 5. Suitable for DN15 DN20 Pipeline-gas globe valve 6. Material of Shell: ABS, electrostatic resistance surface
CA-386D-D2J
Specifications
Alarm Concentration: Hydrogen:125~750*10 -6Natural Gas:1-25%LEL Liquefied Petroleum Gas:1~25%LEL Power Supply: Power Monitoring: AC220V/50Hz 5W
Operation Condition: Temperature:-100C~+500C Relative Humidity: 30%~95 %( Non-condensing) Respond Time: Recovery Time: 20 S 20 S
Time of Shutoff the Valve :< =15S Torque: Dimension: 30kg.cm The Detector: 145X80X50 mm The Valve: 110X110X85 mm
1. Detection Gas: manufactured gas (hydrogen), natural gas, liquefied petroleum gas (LPG) 2. Excellent sensor, stable and long-life, excellent oil smoke resistant performance 3. Alarm Output: visual light and audio alarm, solenoid valve signal, net-work signal output 4. Material of Shell: ABS, electrostatic resistance surface
CA-386D-B
CA-386D-C
Specifications
Model: Alarm Concentration: Power Supply: Power Monitoring: Operation Condition: Respond Time: Recovery Time: Detector Size CA-386D-B CA-386D-C Hydrogen:125~750*10-6Natural Gas:1-25%LEL Liquefied Petroleum Gas:1~25%LEL DC12V-DC24V DC12V-DC24V 1W 1W Temperature:-100C~+500C Relative Humidity: 30%~95 % 20 S 20 S 90*56*18mm 100*50mm
Specifications
Model: Alarm Concentration: Power Supply: Power Monitoring: Operation Condition: Respond Time: Recovery Time: Detector Size CA-386D Hydrogen:125~750*10-6Natural Gas:1-25%LEL Liquefied Petroleum Gas:1~25%LEL AC220V/50Hz 4W Temperature:-100C~+500C Relative Humidity: 30%~95 %( Non-condensing) 20 S 20 S 130X80X50 (mm)
Features:
1. Detection Gas: manufactured gas (hydrogen), natural gas, liquefied petroleum gas (LPG) 2. Excellent Imported sensor, stable and long-life, excellent oil smoke resistant performance 3. Alarm Output: Led Display visual light and audio alarm, solenoid valve signal, net-work signal output 4. Material of Shell: ABS, electrostatic resistance surface
Specifications
Model: Alarm Concentration: Power Supply: Power Monitoring: Operation Condition: Display Range CA-389A Hydrogen:125~750*10-6Natural Gas:1-25%LEL Liquefied Petroleum Gas:1~25%LEL AC220V/50Hz(Adjustable) 4W Temperature:-100C~+500C Relative Humidity: 30%~95 %( Non-condensing) 1%LEL---100%LEL
Features:
1.Use imported, reliable,sensitive and long performance life electrochemical sensor. 2.Superbright LED Display 3.Four level sub-alarm. 4.Audible and Visual alarm 5.Portability,Safety,Reliable 6.Easy installation and maintenancel(Wall mounted) 7.Low-battery warning
Specification
1.Detection Principle: Electrochemical cell 2.Display: Superbright LED Display 3.Power light: Green LED flashes once every 30 seconds 3.Low-battery warning 4. Alarm Density: Under65ppm, Alarms Not Activate 70ppm-150ppm, Alarms Within 60~189 minutes 150-400ppm, Alarms Within 10~50 minutes 400ppm-700ppm,Alarms Within 4~15 minutes 700ppm-800ppm,Alarms Within 2~6 minutes
Specifications
Applicable Gas: Natural Gas, LPG, Manufactured Gas Brass Alloy/ Aluminium NBR Rubber -100C~+500C Way of Switch off DC Pulse Drive/ Manual Driving Voltage Drive Current Time off Valve DC9V~DC12V (Pulse) 1A (pulse) <1S
Address: No.1-4,2 2nd Floor No. 93 ZiJin Road, Xiangzhou District, Zhuhai, Guangdong Province, China
Tel: 0756-2172385 0756-2172385 Fax :0756-2172386 Web Site: http://caatm.en.alibaba.com http://www.caatm.com.cn E-mail: [email protected] [email protected]