Positron emission tomography (PET)[6] is a nuclear medical imaging technique that produces a three-dimensional image or picture of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Three-dimensional images of tracer concentration within the body are then constructed by computer analysis. In modern scanners, three dimensional imaging is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine.
Image of a typical positron emission tomography (PET) facility
If the biologically active molecule chosen for PET is FDG, an analogue of glucose, the concentrations of tracer imaged then give tissue metabolic activity, in terms of regional glucose uptake. Use of this tracer to explore the possibility of cancer metastasis (i.e., spreading to other sites) is the most common type of PET scan in standard medical care (90% of current scans). However, on a minority basis, many other radiotracers are used in PET to image the tissue concentration of many other types of molecules of interest.
History
PET/CT-System with 16-slice CT; the ceiling mounted device is an The concept of emission and transmission tomography injection pump for CT contrast agent was introduced by David E. Kuhl, Luke Chapman and Roy Edwards in the late 1950s. Their work later led to the design and construction of several tomographic instruments at the University of Pennsylvania.
Tomographic imaging techniques were further developed by Michel Ter-Pogossian, Michael E. Phelps and others at Washington University School of Medicine.[7][8] Work by Gordon Brownell, Charles Burnham and their associates at the Massachusetts General Hospital beginning in the 1950s contributed significantly to the development of PET technology and included the first demonstration of annihilation radiation for medical imaging.[9] Their innovations, including the use of light pipes and volumetric analysis, have been important in the deployment of PET imaging. In 1961, James Robertson and his associates at Brookhaven National Laboratory built the first single-plane PET scan, nicknamed the "head-shrinker."[10] One of the factors most responsible for the acceptance of positron imaging was the development of radiopharmaceuticals. In particular, the development of labeled 2-fluorodeoxy-D-glucose (2FDG) by the Brookhaven group under the direction of Al Wolf and Joanna Fowler was a major factor in expanding the scope of PET imaging.[11] The Whole-body PET scan using 18F-FDG compound was first administered to two normal human volunteers by Abass Alavi in August 1976 at the University of Pennsylvania. Brain images obtained with an ordinary (non-PET) nuclear scanner demonstrated the concentration of FDG in that organ. Later, the substance was used in dedicated positron tomographic scanners, to yield the modern procedure. The logical extension of positron instrumentation was a design using two 2-dimensional arrays. PC-I was the first instrument using this concept and was designed in 1968, completed in 1969 and reported in 1972. The first applications of PC-I in tomographic mode as distinguished from the computed tomographic mode were reported in 1970.[12] It soon became clear to many of those involved in PET development that a circular or cylindrical array of detectors was the logical next step in PET instrumentation. Although many investigators took this approach, James Robertson[13] and Z.H. Cho[14] were the first to propose a ring system that has become the prototype of the current shape of PET. The PET/CT scanner, attributed to Dr David Townsend and Dr Nutt was named by TIME Magazine as the medical invention of the year in 2000.[15]
Description
Operation
To conduct the scan, a short-lived radioactive tracer isotope is injected into the living subject (usually into blood circulation). The tracer is chemically incorporated into a biologically active molecule. There is a waiting period while the active molecule becomes concentrated in tissues of interest; then the subject is placed in the imaging scanner. Schematic view of a detector block and ring of a The molecule most commonly used for this purpose is PET scanner fluorodeoxyglucose (FDG), a sugar, for which the waiting period is typically an hour. During the scan a record of tissue concentration is made as the tracer decays.
As the radioisotope undergoes positron emission decay (also known as positive beta decay), it emits a positron, an antiparticle of the electron with opposite charge. The emitted positron travels in tissue for a short distance (typically less than 1mm, but dependent on the isotope[16]), during which time it loses kinetic energy, until it decelerates to a point where it can interact with an electron.[17] The encounter annihilates both electron and positron, producing a pair of annihilation (gamma) photons moving in approximately opposite directions. These are detected when they reach a scintillator in the scanning device, creating a burst of light Schema of a PET acquisition process which is detected by photomultiplier tubes or silicon avalanche photodiodes (Si APD). The technique depends on simultaneous or coincident detection of the pair of photons moving in approximately opposite direction (it would be exactly opposite in their center of mass frame, but the scanner has no way to know this, and so has a built-in slight direction-error tolerance). Photons that do not arrive in temporal "pairs" (i.e. within a timing-window of a few nanoseconds) are ignored.
available with integrated high-end multi-detector-row CT scanners (so-called "PET/CT"). Because the two scans can be performed in immediate sequence during the same session, with the patient not changing position between the two types of scans, the two sets of images are more-precisely registered, so that areas of abnormality on the PET imaging can be more perfectly correlated with anatomy on the CT images. This is very useful in showing detailed views of moving organs or structures with higher anatomical variation, which is more common outside the brain. At the Jlich Institute of Neurosciences and Biophysics, the world's largest PET/MRI device began operation in April 2009: a 9.4-tesla magnetic resonance tomograph (MRT) combined with a positron emission tomograph (PET). Presently, only the head and brain can be imaged at these high magnetic field strengths.[19]
Limitations
The minimization of radiation dose to the subject is an attractive feature of the use of short-lived radionuclides. Besides its established role as a diagnostic technique, PET has an expanding role as a method to assess the response to therapy, in particular, cancer therapy,[21] where the risk to the patient from lack of knowledge about disease progress is much greater than the risk from the test radiation. Limitations to the widespread use of PET arise from the high costs of cyclotrons needed to produce the short-lived radionuclides for PET scanning and the need for specially adapted on-site chemical synthesis apparatus to produce the radiopharmaceuticals after radioisotope preparation. Organic radiotracer molecules that will contain a positron-emitting radioisotope cannot be synthesized first and then the radioisotope prepared within them, because bombardment with a cyclotron to prepare the radioisotope destroys any organic carrier for it. Instead, the isotope must be prepared first, then afterward, the chemistry to prepare any organic radiotracer (such as FDG) accomplished very quickly, in the short time before the isotope decays. Few hospitals and universities are capable of maintaining
Positron emission tomography such systems, and most clinical PET is supported by third-party suppliers of radiotracers that can supply many sites simultaneously. This limitation restricts clinical PET primarily to the use of tracers labelled with fluorine-18, which has a half-life of 110 minutes and can be transported a reasonable distance before use, or to rubidium-82 (used as rubidium-82 chloride) with a half-ife of 1.27 minutes, which is created in a portable generator and is used for myocardial perfusion studies. Nevertheless, in recent years a few on-site cyclotrons with integrated shielding and "hot labs" (automated chemistry labs that are able to work with radioisotopes) have begun to accompany PET units to remote hospitals. The presence of the small on-site cyclotron promises to expand in the future as the cyclotrons shrink in response to the high cost of isotope transportation to remote PET machines[22] Because the half-life of fluorine-18 is about two hours, the prepared dose of a radiopharmaceutical bearing this radionuclide will undergo multiple half-lives of decay during the working day. This necessitates frequent recalibration of the remaining dose (determination of activity per unit volume) and careful planning with respect to patient scheduling.
Image reconstruction
The raw data collected by a PET scanner are a list of 'coincidence events' representing near-simultaneous detection (typically, within a window of 6 to 12 nanoseconds of each other) of annihilation photons by a pair of detectors. Each coincidence event represents a line in space connecting the two detectors along which the positron emission occurred (i.e., the line of response (LOR)). Modern systems with a higher time resolution (roughly 3 nanoseconds) also use a technique (called "Time-of-flight") where they more precisely decide the difference in time between the detection of the two photons and can thus localize the point of origin of the annihilation event between the two detectors to within 10cm. Coincidence events can be grouped into projection images, called sinograms. The sinograms are sorted by the angle of each view and tilt (for 3D images). The sinogram images are analogous to the projections captured by computed tomography (CT) scanners, and can be reconstructed in a similar way. However, the statistics of the data are much worse than those obtained through transmission tomography. A normal PET data set has millions of counts for the whole acquisition, while the CT can reach a few billion counts. As such, PET data suffer from scatter and random events much more dramatically than CT data does. In practice, considerable pre-processing of the data is requiredcorrection for random coincidences, estimation and subtraction of scattered photons, detector dead-time correction (after the detection of a photon, the detector must "cool down" again) and detector-sensitivity correction (for both inherent detector sensitivity and changes in sensitivity due to angle of incidence). Filtered back projection (FBP) has been frequently used to reconstruct images from the projections. This algorithm has the advantage of being simple while having a low requirement for computing resources. However, shot noise in the raw data is prominent in the reconstructed images and areas of high tracer uptake tend to form streaks across the image. Also, FBP treats the data deterministicallyit does not account for the inherent randomness associated with PET data, thus requiring all the pre-reconstruction corrections described above. Iterative expectation-maximization algorithms are now the preferred method of reconstruction. These algorithms compute an estimate of the likely distribution of annihilation events that led to the measured data, based on statistical principles. The advantage is a better noise profile and resistance to the streak artifacts common with FBP, but the disadvantage is higher computer resource requirements.[23] Recent research has shown that Bayesian methods that involve a Poisson likelihood function and an appropriate prior (e.g., a smoothing prior leading to total variation regularization or a Laplacian prior leading to -based regularization in a wavelet or other domain) may yield superior performance to expectation-maximization-based methods which involve a Poisson likelihood function but do not involve such a prior.[24][25][26] Attenuation correction: Attenuation occurs when photons emitted by the radiotracer inside the body are absorbed by intervening tissue between the detector and the emission of the photon. As different LORs must traverse different
Positron emission tomography thicknesses of tissue, the photons are attenuated differentially. The result is that structures deep in the body are reconstructed as having falsely low tracer uptake. Contemporary scanners can estimate attenuation using integrated x-ray CT equipment, however earlier equipment offered a crude form of CT using a gamma ray (positron emitting) source and the PET detectors. While attenuation-corrected images are generally more faithful representations, the correction process is itself susceptible to significant artifacts. As a result, both corrected and uncorrected images are always reconstructed and read together. 2D/3D reconstruction: Early PET scanners had only a single ring of detectors, hence the acquisition of data and subsequent reconstruction was restricted to a single transverse plane. More modern scanners now include multiple rings, essentially forming a cylinder of detectors. There are two approaches to reconstructing data from such a scanner: 1) treat each ring as a separate entity, so that only coincidences within a ring are detected, the image from each ring can then be reconstructed individually (2D reconstruction), or 2) allow coincidences to be detected between rings as well as within rings, then reconstruct the entire volume together (3D). 3D techniques have better sensitivity (because more coincidences are detected and used) and therefore less noise, but are more sensitive to the effects of scatter and random coincidences, as well as requiring correspondingly greater computer resources. The advent of sub-nanosecond timing resolution detectors affords better random coincidence rejection, thus favoring 3D image reconstruction.
Applications
PET is both a medical and research tool. It is used heavily in clinical oncology (medical imaging of tumors and the search for metastases), and for clinical diagnosis of certain diffuse brain diseases such as those causing various types of dementias. PET is also an important research tool to map normal human brain and heart function. PET is also used in pre-clinical studies using animals, where it allows repeated investigations into the same subjects. This is particularly valuable in cancer research, as it results in an increase in the statistical quality of the data (subjects can act as their own control) and substantially reduces the numbers of animals required for a given study. Alternative methods of scanning include x-ray computed tomography (CT), magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI), ultrasound and single-photon emission computed tomography (SPECT). While some imaging scans such as CT and MRI isolate organic anatomic changes in the body, PET and SPECT are capable of detecting areas of molecular biology detail (even prior to anatomic change). PET scanning does this using radiolabelled molecular probes that have different rates of uptake depending on the type and function of tissue involved. Changing of regional blood flow in various anatomic structures (as a measure of the injected positron emitter) can be visualized and relatively quantified with a PET scan. PET imaging is best performed using a dedicated PET scanner. However, it is possible to acquire PET images using a conventional dual-head gamma camera fitted with a coincidence detector. The quality of gamma-camera PET is considerably lower, and acquisition is slower. However, for institutions with low demand for PET, this may allow on-site imaging, instead of referring patients to another center, or relying on a visit by a mobile scanner. PET is a valuable technique for some diseases and disorders, because it is possible to target the radio-chemicals used for particular bodily functions.
Oncology
Oncology: PET scanning with the tracer fluorine-18 (F-18) fluorodeoxyglucose (FDG), called FDG-PET, is widely used in clinical oncology. This tracer is a glucose analog that is taken up by glucose-using cells and phosphorylated by hexokinase (whose mitochondrial form is greatly elevated in rapidly growing malignant tumours). A typical dose of FDG used in an oncological scan is 200-400 MBq for an adult human. Because the oxygen atom that is replaced by F-18 to generate FDG is required for the next step in glucose metabolism in all cells, no further reactions occur in FDG. Furthermore, most tissues (with the notable exception of liver and kidneys) cannot remove the phosphate added by hexokinase. This means that FDG is trapped in any cell that takes it up, until it decays, since phosphorylated sugars, due to their ionic charge, cannot exit from the cell. This results in intense radiolabeling of tissues with high glucose uptake, such as the brain, the liver, and most cancers. As a result, FDG-PET can be used for diagnosis, staging, and monitoring treatment of cancers, particularly in Hodgkin's lymphoma, non-Hodgkin lymphoma, and lung cancer. Many other types of solid tumors will be found to be very highly labeled on a case-by-case basisa fact that becomes especially useful in searching for tumor metastasis, or for recurrence after a known highly active primary tumor is removed. Because individual PET scans are more expensive than "conventional" imaging with computed tomography (CT) and magnetic resonance imaging (MRI), expansion of FDG-PET in cost-constrained health services will depend on proper health technology assessment; this problem is a difficult one because structural and functional imaging often cannot be directly compared, as they provide different information. Oncology scans using FDG make up over 90% of all PET scans in current practice. A few other isotopes and radiotracers are slowly being introduced into oncology for specific purposes. For example, 11C-Metomidate has been used to detect tumors of adrenocortical origin.[27][28] Also, FDOPA PET/CT, in centers which offer it, has proven to be a more sensitive alternative to finding, and also localizing pheochromocytoma than the MIBG scan.[29][30][31]
Neuroimaging
Neurology: PET neuroimaging is based on an assumption that areas of high radioactivity are associated with brain activity. What is actually measured indirectly is the flow of blood to different parts of the brain, which is, in general, believed to be correlated, and has been measured using the tracer oxygen-15. However, because of its 2-minute half-life, O-15 must be piped directly from a medical cyclotron for such uses, which is difficult. In practice, since the brain is normally a rapid user of glucose, and since brain pathologies such as Alzheimer's disease greatly decrease brain metabolism of both glucose and oxygen in tandem, standard FDG-PET of the brain, which measures regional glucose use, may also be successfully used to differentiate Alzheimer's disease from other dementing processes, and also to make early diagnosis of Alzheimer's disease. The advantage of FDG-PET for these uses is its much wider availability. PET imaging with FDG can also be PET scan of the human brain. used for localization of seizure focus: A seizure focus will appear as hypometabolic during an interictal scan. Several radiotracers (i.e. radioligands) have been developed for PET that are ligands for specific neuroreceptor subtypes such as [11C] raclopride and [18F] fallypride for dopamine D2/D3 receptors, [11C]McN 5652 and [11C] DASB for serotonin transporters, or enzyme substrates (e.g. 6-FDOPA for the AADC enzyme). These agents permit the visualization of neuroreceptor pools in the context of a plurality of neuropsychiatric and neurologic illnesses. The development of a number of novel probes for noninvasive, in vivo PET imaging of neuroaggregate in human brain has brought amyloid imaging to the doorstep of clinical use. The
Positron emission tomography earliest amyloid imaging probes included 18 18 [32] 2-(1-{6-[(2-[ F]fluoroethyl)(methyl)amino]-2-naphthyl}ethylidene)malononitrile ([ F]FDDNP) developed at 11 the University of California, Los Angeles and N-methyl-[ C]2-(4'-methylaminophenyl)-6-hydroxybenzothiazole[33] (termed Pittsburgh compound B) developed at the University of Pittsburgh. These amyloid imaging probes permit the visualization of amyloid plaques in the brains of Alzheimer's patients and could assist clinicians in making a positive clinical diagnosis of AD pre-mortem and aid in the development of novel anti-amyloid therapies. [11C]PMP (N-[11C]methylpiperidin-4-yl propionate) is a novel radiopharmaceutical used in PET imaging to determine the activity of the acetylcholinergic neurotransmitter system by acting as a substrate for acetylcholinesterase. Post-mortem examination of AD patients have shown decreased levels of acetylcholinesterase. [11C]PMP is used to map the acetylcholinesterase activity in the brain, which could allow for pre-mortem diagnosis of AD and help to monitor AD treatments.[34] Avid Radiopharmaceuticals of Philadelphia has developed a compound called 18F-AV-45 that uses the longer-lasting radionuclide fluorine-18 to detect amyloid plaques using PET scans.[35] 2. Neuropsychology / Cognitive neuroscience: To examine links between specific psychological processes or disorders and brain activity. 3. Psychiatry: Numerous compounds that bind selectively to neuroreceptors of interest in biological psychiatry have been radiolabeled with C-11 or F-18. Radioligands that bind to dopamine receptors (D1,[36] D2, reuptake transporter), serotonin receptors (5HT1A, 5HT2A, reuptake transporter) opioid receptors (mu) and other sites have been used successfully in studies with human subjects. Studies have been performed examining the state of these receptors in patients compared to healthy controls in schizophrenia, substance abuse, mood disorders and other psychiatric conditions.
Cardiology
Cardiology, atherosclerosis and vascular disease study: In clinical cardiology, FDG-PET can identify so-called "hibernating myocardium", but its cost-effectiveness in this role versus SPECT is unclear. FDG-PET imaging of atherosclerosis to detect patients at risk of stroke is also feasible and can help test the efficacy of novel anti-atherosclerosis therapies.[37][38]
Pharmacology
Pharmacology: In pre-clinical trials, it is possible to radiolabel a new drug and inject it into animals. Such scans are referred to as biodistribution studies. The uptake of the drug, the tissues in which it concentrates, and its eventual elimination, can be monitored far more quickly and cost effectively than the older technique of killing and dissecting the animals to discover the same information. Much more commonly, however, drug occupancy at a purported site of action can be inferred indirectly by competition studies between unlabeled drug and radiolabeled compounds known apriori to bind with specificity to the site. A single radioligand can be used this way to test many potential drug candidates for the same target. A related technique involves scanning with radioligands that compete with an endogenous (naturally occurring) substance at a given receptor to demonstrate that a drug causes the release of the natural substance. The following is an excerpt from an article by Harvard University staff writer Peter Reuell, featured in HarvardScience, part of the online version of the Harvard Gazette newspaper, which discusses research by the team of Harvard Associate Professor of Organic Chemistry and Chemical Biology Tobias Ritter: "A new chemical process ... may increase the utility of positron emission tomography (PET) in creating real-time 3-D images of chemical activity occurring inside the body. This new work ... holds out the tantalizing possibility of using PET scans to peer into a number of functions inside animals and humans by simplifying the process of using tracer molecules to create the 3-D images." (by creating a novel electrophilic fluorination reagent as an intermediate molecule; the research could be used in drug development).[39]
Musculo-skeletal imaging
Musculo-Skeletal Imaging: PET has been shown to be a feasible technique for studying skeletal muscles during exercises like walking.[41] One of the main advantages of using PET is that it can also provide muscle activation data about deeper lying muscles such as the vastus intermedialis and the gluteus minimus, as compared to other muscle studying techniques like electromyography, which can be used only on superficial muscles (i.e., directly under the skin). A clear disadvantage, however, is that PET provides no timing information about muscle activation, because it has to be measured after the exercise is completed. This is due to the time it takes for FDG to accumulate in the activated muscles.
Safety
PET scanning is non-invasive, but it does involve exposure to ionizing radiation. The total dose of radiation is significant, usually around 57 mSv. However, in modern practice, a combined PET/CT scan is almost always performed, and for PET/CT scanning, the radiation exposure may be substantialaround 2326 mSv (for a 70kg persondose is likely to be higher for higher body weights).[42] When compared to the classification level for radiation workers in the UK of 6 mSv, it can be seen that use of a PET scan needs proper justification. This can also be compared to 2.2 mSv average annual background radiation in the UK, 0.02 mSv for a chest x-ray and 6.58 mSv for a CT scan of the chest, according to the journal Chest and ICRP.[43][44] A policy change suggested by the IFALPA member associations in year 1999 mentioned that an aircrew member is likely to receive a radiation dose of 49 mSv per year.[45]
References
[1] [2] [3] [4] [5] [6] http:/ / icd9cm. chrisendres. com/ index. php?srchtype=procs& srchtext=92. 0& Submit=Search& action=search http:/ / icd9cm. chrisendres. com/ index. php?srchtype=procs& srchtext=92. 1& Submit=Search& action=search http:/ / www. nlm. nih. gov/ cgi/ mesh/ 2011/ MB_cgi?field=uid& term=D049268 http:/ / ops. icd-code. de/ ops/ code/ 3-74. html http:/ / www. nlm. nih. gov/ medlineplus/ ency/ article/ 003827. htm Bailey, D.L; D.W. Townsend, P.E. Valk, M.N. Maisey (2005). Positron Emission Tomography: Basic Sciences (http:/ / www. springer. com/ ?SGWID=0-102-24-0-0& searchType=EASY_CDA& queryText=Positron+ Emission+ Tomography:+ Basic+ Sciences). Secaucus, NJ: Springer-Verlag. ISBN1-85233-798-2. . [7] Ter-Pogossian, M.M.; M.E. Phelps, E.J. Hoffman, N.A. Mullani (1975). "A positron-emission transaxial tomograph for nuclear imaging (PET)". Radiology 114 (1): 8998. OSTI4251398. PMID1208874. [8] Phelps, M.E.; E.J. Hoffman, N.A. Mullani, M.M. Ter-Pogossian (March 1, 1975). "Application of annihilation coincidence detection to transaxial reconstruction tomography" (http:/ / jnm. snmjournals. org/ cgi/ content/ abstract/ 16/ 3/ 210). Journal of Nuclear Medicine 16 (3): 210224. PMID1113170. . [9] Sweet, W.H.; G.L. Brownell (1953). "Localization of brain tumors with positron emitters". Nucleonics 11: 4045. [10] A Vital Legacy: Biological and Environmental Research in the Atomic Age, U.S. Department of Energy, The Office of Biological and Environmental Research, September 2010, p 25-26 [11] IDO, T., C-N. WAN, V. CASELLA, J.S. FOWLER, A.P. WOLF, M. REIVICH, and D.E. KUHL, ``Labeled 2-deoxy-D-glucose analogs. -labeled 2-deoxy-2-fluoro-D-glucose, 2-deoxy-2-fluoro-D-mannose and C-14-2-deoxy-2-fluoro-D-glucose, The Journal of Labelled Compounds and Radiopharmaceuticals 1978; 14:175-182. [12] BROWNELL G.L., Dave Marcum, B. HOOP JR., and D.E. BOHNING, "Quantitative dynamic studies using short-lived radioisotopes and positron detection" in Proceedings of the Symposium on Dynamic Studies with Radioisotopes in Medicine, Rotterdam. August 31September 4, 1945. IAEA. Vienna. 194824. pp. 161172.
10
11
External links
PET Images (http://rad.usuhs.edu/medpix/master.php3?mode=image_finder&action=search&srchstr=& srch_type=all&labels=&details=2&no_filter=2&plane_id=&capt_id=-4&filter_m=modality&filter_o=& acr_pre=&filter_p=&acr_post=#top) Search MedPix(r) Seeing is believing: In vivo functional real-time imaging of transplanted islets using positron emission tomography (PET) (a protocol) (http://www.natureprotocols.com/2006/12/21/ seeing_is_believing_in_vivo_fu_1.php), Nature Protocols, from Nature Medicine 12, 14231428 (2006). The nuclear medicine and molecular medicine podcast (http://nuccast.com)Podcast Positron Emission Particle Tracking (http://www.np.ph.bham.ac.uk/pic/pept.htm) (PEPT)engineering analysis tool based on PET that is able to track single particles in 3D within mixing systems or fluidised beds. Developed at the University of Birmingham, UK. CMS coverage of PET scans (http://www.hematologytimes.com/ht/p_article.do?id=948) PET-CT atlas Harvard Medical School (http://www.med.harvard.edu/JPNM/chetan/) National Isotope Development Center (http://isotopes.gov/)U.S. government source of radionuclides including those for PETproduction, research, development, distribution, and information