Power Amp BK 2720
Power Amp BK 2720
Power Amp BK 2720
Power Amplifier Type 2720 has been especially designed to drive Modal Exciter Type 4825 but can be used with any vibration or modal exciter requiring a 500 VA power amplifier.
USES
To drive Modal Exciter Type 4825 To drive any modal or vibration
FEATURES
500 VA power output Adjustable RMS output-current
limit
Low or high output impedance Low distortion over wide
frequency range 010214 Extensive built-in protection, including interlock Rear panel voltage and current monitor points Front panel indicator LEDs showing clipped output signal, temperature overload, current overload, output signal phase (0 or 180), operating mode (current or voltage), current state and interlock input disabled Multifunction display (backlit LCD) showing approximate output current and output voltage Powers DC Static Centering Unit Type 1056 (optional) if used with Type 2720
Description
Power Amplifier Type 2720 has a useable frequency range from 40 Hz to 15 kHz (full capacity) or DC to 150 kHz (reduced capacity). The rated AC output is 500 VA into a 4 W exciter or resistive load, in the frequency range DC to 15 kHz (0.5 dB). The maximum voltage gain is 25 dB. Harmonic content of the output is very small as heavy negative feedback is used. The instrument can tolerate temperature and supply line variations while maintaining excellent stability. Type 2720 can be used as a voltage generator with low output impedance and a flat voltage frequency response, or as a current generator with high output impedance and a flat current frequency response. The RMS output-current limit is adjustable. The instrument consists of an input stage, a preamplifier, a power amplifier and various warning and safety circuits with indication lamps. A multifunction display shows output current and output voltage.
Protection
Type 2720 features extensive protection circuits for itself and the connected vibration exciter. When triggered, the protection circuits disconnect the input signal and an LED lights up, indicating the reason for the instrument shutdown. Overload protection against excessive coil current is provided by setting the RMS output current to between 1 and 11 A. This enables Type 2720 to safely drive modal and vibration exciters with different maximum current ratings. The signal to the exciter is switched off if the preset current limit is exceeded, and the red current LED will light up. The power output stage is protected by a temperaturesensing safety device to prevent output transistor temperatures that exceed design limits and lead to transistor failure. The temperature protection circuit blocks the amplifier input signal, lighting the red temperature LED. Further protection is provided by an interlock relay that disconnects the input if the operator switches between voltage mode and current mode during operation. Resetting after current, temperature and interlock shutdown is done by simply turning the amplifier gain control fully anticlockwise.
2720
Power on/off Continuously variable gain control, 0 to Cal. (25 dB) with integral reset Continuously variable current limit control 1 to 11 A (RMS) Switch for voltage mode or current mode operation Switch for phase inversion (0 or 180) between input and output
INDICATOR LAMPS (LED)
Clipping Temperature overload Current overload State Voltage mode Current mode Interlock Phase (0 or 180)
MULTIFUNCTION DISPLAY (LCD)
500 VA into a 4 W exciter or resistive load, at 25C and nominal mains voltage. 144 VA into a 1 W exciter or resistive load, at 40C or at 10% above nominal mains voltage (4-pin Neutrik SPEAKON socket at rear panel)
OUTPUT VOLTAGE CAPACITY
Voltage, RMS, read-out accuracy 5% 2 digit, 40 Hz to 15 kHz Current, RMS, read-out accuracy 5% 2 digit, 40 Hz to 15 kHz
PROTECTION
45 V RMS, DC to 15 kHz
OUTPUT CURRENT CAPACITY
Input signal is removed and an indicator lamp is lit when the following parameters exceed preset limits: Driver Coil Current true RMS adjustable limit 1 to 11 A (RMS) Power Transistor Temperature Heat Sink Temperature Output Signal Distortion no shut-down
OTHER FEATURES
25 dB ( 2 dB) @ 1 kHz Full capacity: 40 Hz to 15 kHz Reduced capacity: DC to 150 kHz (20 dB)
FREQUENCY RESPONSE
Electronic peak current limiting Single phase 100, 120, 230 V RMS, 10%, 50 60 Hz. Approx. 1000 VA at full load Power insert connector with fuse cartridge and voltage selector at rear
FUSES POWER REQUIREMENTS
Typical small signal response (20 dB) in low impedance mode: DC Input: DC to 15 kHz 0.5 dB; DC to 150 kHz 3 dB AC Input: 15 Hz to 15 kHz 0.5 dB (2 separate BNC sockets at rear panel)
THD AT FULL OUTPUT CAPACITY
to to to to
5 kHz) Low Impedance Mode 15 kHz) Low Impedance Mode 2 kHz) High Impedance Mode 15 kHz) High Impedance Mode
Height: 2 HE equivalent of 88 mm (3.5 in.) Width: 482.6 mm (19 in.) with flanges for standard 19-inch rack mounting Depth: 450 mm (13.8 in)
WEIGHT
21 kg (46 lb.)
MONITOR OUTPUT
Ordering Information
TYPE 2720 POWER AMPLIFIER OPTIONAL ACCESSORIES
Brel & Kjr reserves the right to change specifications and accessories without notice
HEADQUARTERS: DK-2850 Nrum Denmark Telephone: +4545800500 Fax: +4545801405 http://www.bksv.com e-mail: [email protected] Australia (02)9450-2066 Austria 0043-1-8657400 Brazil (011)5182-8166 Canada (514)695-8225 China (86) 1068029906 Czech Republic 02-67021100 Finland (0)9-755 950 France (01)69907100 Germany 06103/733 5-0 Hong Kong 25487486 Hungary (1)2158305 Ireland (01)803 7600 Italy 02 57 68061 Japan 03-3779-8671 Republic of Korea (02)3473-0605 Netherlands (31)318 559290 Norway 66771155 Poland (22)858 9392 Portugal (1)4711453 Singapore (65) 377- 4512 Slovak Republic 421 2 5443 0701 Spain (91)6590820 Sweden (08)4498600 Switzerland (0)1 880 70 35 Taiwan (02)7139303 United Kingdom (0)1438 739 000 USA 800 332 2040 Local representatives and service organisations worldwide
BP 1947 - 11
01/12
AQ 0649 AQ 0648
Cable with 4-pin Neutrik SPEAKON plug, 5 metres Extension cable with Neutrik SPEAKON 4-pin connector at both ends, 10 metres
Rosendahls Bogtrykkeri
Less than 100 mV drift from 0 V for 10% variation of mains supply from nominal, and for 10 to 40C (50 to 104F) variation in ambient temperature
Voltage: 0.1 V/V 3%, 5 Hz to 15 kHz Current: 0.1 V/A 3%, 5 Hz to 15 kHz