Art's Process Spec Sheets
Art's Process Spec Sheets
Art's Process Spec Sheets
Specification Sheets Included in This WorkBook 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Art's API 650 Storage Tank Art's Centrifugal Pump Art's Air-Cooled Exchanger Art's Shell & Tube Exchanger Art's Plate & Frame Heat Exchanger Art's Process Vessel Art's Control Valve Art's Centrifugal Blower Art's Orifice Meter Art's Coriolis Meter Art's Ultrasonic Meter Art's Mass Meter Art's Turbine Meter Art's Vortex Meter Art's Magnetic Meter Art's .
The accurate and complete preparation of Specification Sheets is one of the most (if not THE most) important capabilities that a Chemical, Process, or Project Engineer should acquire very early in his/her career. An engineer is a problem solver, pure and simple. However, one cannot simply solve problems by directly applying ones own efforts and time. In the industrial and competitive world, an engineer simply does not have the time available to do all that must be done in order to resolve day-to-day problems. That is why engineers are required to lead and supervise those around them in order to assure an organized team-effort in resolving problems. To this end, engineers use communications skills (both oral and written) as well as language, psychology, and interpersonal skills to inform and lead other team members to a successful resolution. At the very basic foundation of problem solving is the successful communications of the required capital equipment required to resolve engineering problems. An engineer is unable to resolve a problem if he/she is unable to successfully describe it in detail to the "stake holders" in a project. The ability to receive constructive and cost-effective help and supply from parties involved in the project is directly related to the timely and accurate description of the supply needed to resolve a problem. Specification sheets are the indicated tools that are relied upon by engineers to convey an accurate and detailed description of their needs and expected supply. These Specification sheets not only serve to identify the required supply, they also serve to organize and structure the knowldege of the owner's engineers as to the criticality and strategic importance of the supply. They force the Owner to comply with the classic business rule: Emptor Caveat - buyer beware. It is a basic business principle and law that the responsibility of defining the specific need for a supply of goods or materials lies directly with the purchaser (or Owner). If you don't know what you need or don't know how to describe what you need, you will never resolve your own problems. The Specification Sheet describes to others not only what you identify as your specific needs, it also documents them and communicates this information to all interested parties. A large part of the problem in preparing accurate Spec Sheets is that the lead engineers (who often are the most experienced and knowledgeable) are not the ones that prepare the Spec Sheets. It falls upon the Process and Project engineers to prepare them and many times these individuals have to be trained and instructed on how to describe and specify equipment that they are only superficially familiar with. Therefore, good Spec Sheets should be easy and simply to prepare, with a minimum of detail knowledge required. FileName: 166794456.xls.ms_office WorkSheet: Introduction
Page 1 of 27
Art Montemayor
I have arranged and organized the Spec Sheets found in this WorkBook in a manner that they should be rather easy and intuitive for young engineers to prepare. A maximum use is made of drop-down list boxes in order to facilitate the required information to engineers who are unaware of the various feature choices available or much less how to describe them or spell them correctly. This method also "standardizes" a variety of choices and does not leave it up to the individual to select whatever he/she thinks is required. This method also allows the Spec Sheet to impose Corporate standards and pre-selected features without wasting manpower to check their correct usage. The utilization of an electronic spreadsheet such as Excel makes it easy for project documentation to be safely stored, modified, and transmitted with a minimum of manpower. Engineers can generate and process the documentation without further engineering assistance. Additionally, the inherent calculation features of a spreadsheet are utilized to the maximum in allowing for involved calculated information to be self-generated by the spreadsheet automatically. The spreadsheets can be protected by the used/author for assurance that data will not be revised without prior knowledge. The need to have calculations and related documentation readily available and filed due to legalities (such as OSHA requirements on safety relief valve calculations and specifications) makes the spreadsheet a natural tool for these requirements. The utilization of Check boxes and Option buttons also give versatility and compactness to these Spec Sheets, allowing the user to store more details and data in them. I have endeavored to limit the size of the Spec Sheet to one page and design them around the need for communications of Process data for: 1. Documenting the results of calculations and other equipment details; 2. Preparing data and information for procurement inquiries (RFQs - Request of Quotes); 3. Obtaining Supplier information as related to a specific specification; 4. Preparing information that enters the Operations and Maintenance Manuals of a Unit; 5. Transmitting information regarding Unit equipment to other parties. These Spec Sheets should be continuously revised and improved as spreadsheet technology improves or is upgraded. I will continue to work on and add additional Spec Sheets to this WorkBook in order to achieve as complete a set of Spec Sheets as I can attain within the framework of available time.
Page 2 of 27
Art Montemayor
Spec Sheet Log Index of Process/Mechanical Data Sheet and Specification Forms
Equipment Type Agitator, Mixer Pressure Vessel Tower, Column Mist Eliminator Fractionation Tray Data Tower Packing Data Storage Tank (API type) Heat Exchanger, Tubular Heat Exchanger, Plate & Frame Heat Exchanger, Double-Pipe/Multi-tube
go-by
draft*
complete*
debugged
issuable**
Heat Exchanger, Air-cooled Filter, Separator Centrifuge Pump, Centrifugal Pump, Reciprocating/Metering Pump, Rotary (Gear, Screw, Lobe, etc.) Pump, Progressive Cavity Compressor, Centrifugal Compressor, Reciprocating Compressor, Screw-type Fan, Blower Vacuum Pump Vacuum Ejector System Eductor, Mixing Rotary Feeder Valve Weigh-Feeder Solids Blender In-line Mixer
Electric Motor
Auxiliaries, Other
Page 3 of 27
Art Montemayor
Spec Sheet Log Index of Process/Mechanical Data Sheet and Specification Forms
go-by
draft*
complete*
debugged
accepted
Instrument Specifications
Page 4 of 27
Project No.
1 Service : 2 Location :
Equipment No. :
Kirwin
Mfr Ref. No. :
Model : 3 Manufacturer : 4 P&ID No. PID115-EPF-01-112A1 Plot Plan No. : 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Shell Diameter : 25 Roof Type : 26
Two
M G
50.00 Ft H 32.00 Ft E L F N1
50.00 Cone
Feet Shell Height : 48" X 48" FLUSH CLEANOUT
E D
N2
32.00
J
Feet
I
Nominal Volume :
11,191
Barrels
Sloped
NOZZLES/CONNECTIONS Qty 2 2 1 1 1 1 1 1 1 1 1 1 1 1 Size 24" 24" 48"x48" 6" 1" 8" 10" 30" 4" 8" 3/4" 3/4" 4" 2"
OPERATING/DESIGN DATA
0.7900
Mark A E F G H I J K L M N1 N2 P D
Service Roof Manway Shell Manway Flush Cleanout MW Stilling Vent Temperature Indicator Outlet Nozzle Fill Nozzle Mixer Manway Water Draw Nozzle Top Center Vent Sample Tap Sample Tap Roof Nozzle Spare
psia 5.5 29 Vapor Pressure @ Max. Operating Temperature Design 30 Flash Point (Closed Cup) : F Operating 31 Negative Pressure 32 Positive Pressure oz/in.2 psig F F Yes Set @ CA, in. 0.1250 0.1250 0.0.3 0.00 1.00 0.50 2.00
33 (Hydro)test Pressure expressed in Psig 34 Minimum Fluid Temperature 35 Maximum Fluid Temperature 36 Emergency Vacuum Design ? 37 38 Component 39 Shell & Bottom 40 Roof 41 Lining/Coating 42 43 Stress Relieve ? 44 45 Code (as appl.): 46 Design Specifications: 47 Tank Insulation ? 48 Insulation Type: 49 Fireproofing ? 50 Remarks 51 52 No Hot Yes for: Material 57370 516 Grade 55
----25 200
oz/in.2
Rating 150# 125# 125# 125# 150# 150# 150# 150# 150# 150# 150# 150# 150# 150# 150# 150#
Others: 100 Yes
CONSTRUCTION/FABRICATION
Internals (attach separate sheet, as req'd): Sump Seismic Zone Radiograph 85 EmptyTank Weight
mph lb
Yes
1. Items marked with an asterisk (*) to be completed by Vendor/Fabricator. 2. Fixed cone roof with internal floating roof.
Approvals
Rev 0 Date Description For Inquiry By ArtM Chk. Appr. Rev Date Description By Chk. Appr.
Rev. No.
Montemayor, Inc.
Sheet
1 of 1
Montemayor Corporation
1 Service 2 Location
Project No.
1234567
Equipment No. Crab Juice Transfer Pump P-37 Unit P.O. No. Galveston, Texas Balinese Room Model Mfr Ref. No. No. Req'd 3 Manufacturer * * * One Plot Plan No. 4 P&ID No. Specification Engr: A. Montemayor PID-01-0000 PLT-03-0000 OPERATING CONDITIONS, EACH PUMP 5 6 Liquid Pumped Crab Juice gpm Rated 7 Capacity @ PT, Normal 400 500 8 Suction Pressure 9 10 11 12 13 PERFORMANCE Manufacturer's Proposal Curve No. gpm RPM
* * * *
Thermal CCW % HP ft
No. Stages
Hydr. Eff'y
psig (Norm.) psig (Max.) 14.7 16.7 Disch. Pressure psig (Norm.) psig (Max.) 77.7 90 Differential Pressure 63.0 psi Diff. Head (TDH) 170 ft Temperature, Normal F Max. F 120 190 Specific Gravity @ Max. Temp. 0.854 @ PT 0.839 Vapor Press. @ PT 6.87 psia NPSH Available 14 ft cP cSt Concentration Flammable Chlorides Size Toxic H2S Rating Other: Other: Facing
Rated Brake Power NPSH Req'd @ Impeller CL Min. Flow Req'd Suction Specific Speed
* *
Rev. No.
Sheet
1 of 1
gpm
fps CW Elev.
14 Viscosity @ PT 15 Corrosion/Erosion Caused By: 16 Solids Present 17 Size Distribution 18 Liquid is 19 20 21 Nozzles 22 Suction 23 Discharge 24 25 Case Mount'g 26 Split Axial 27 Case MAWP 28 Connections 29 Impeller 30 31 33 35 Diameter: Mount Lube CL Contains
SSU Location Indoors Ambient Temp. 100 % CW Supply CW Return Electrical Power CONSTRUCTION Location
X Outdoors
F Max. psig @ psig, Min. @
97
ft ASL
10
3
Div.
Ph
60
Group
Hz
Materials Case/Trim (API Class) Casing Int'l Ctg/Lining Impeller Corr. Allow. Gland Wear Rings Sleeve(s) Drip Pan Internal Wear Parts in.
1" 3"
Foot
150# 150#
Brckt
FF RF
Vert. (Type) Radial Steam Jkt Diffuser
Radial Volute
*
Open Rated
F Hydrotest @
psig
Vent
*
Type Thrust
in. Min.
Case
Pressure
Int'stge Bush'gs, Diam. * in.; Cl'rnce Weights and Dimensions Approx. Wt., Pump & Base Motor Wt.
* *
lb
in. in.
*
Turbine Wt.
lb
lb
Packing
Baseplate Dimensions (in.) Baseplate No. API ANSI * Applicable Specifications B73.2
*
API
610 B73.1
40 Gland Tap
ANSI
Customer Specs:
43 CW Piping Mat'ls : 45 API Seal Flush Plan 46 SF Fluid : 47 Auxiliary Seal Plan
Inspection and Tests Req'd Req'd Req'd Req'd Req'd Req'd Witness Witness Witness Witness Witness
48 Auxiliary Seal Flush/Quench Fluid 49 Seal Flush Piping Threaded Socket Weld Flanged 50 Remarks 1. Items marked with an asterisk (*) to be completed by Vendor. 51 52 Rev 0 Date 9-Oct-02 Description For Inquiry By ABC Chk. DEF Appr. XYZ Rev 2. See Motor Data, Sheet 2 of 2.
Date
Description
By
Chk.
Appr.
Corporation
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57
Project No.
1234567
Service Equipment No. Process Vapor Condenser Location Unit P.O. No. Cedar Rapids, Iowa Furfural Manufacturer Model No. Req'd Mfr Ref. No. * * * One Size Type Forced Draft Type: No. of Bays Heat Duty 100,000,000 150 F Surface/Unit, Finned Btu/h Effective MTD ft2; Bare Tube ft2 2 2 2 Transfer Rate, Ext'd Surface : 250 Btu/ft hF Bare Tube - Service : Btu/ft hF Clean : Btu/ft hF P&ID No. Plot Plan No. Other Ref. Dwg No. PERFORMANCE DATA - TUBE SIDE Lethal Service? No Inlet Outlet Fluid Name Specific Heat, Liquid Btu/lbF Total Fluid Entering lb/h Specific Heat, Vapor Btu/lbF In Out Thermal Cond., Liq. Btu/fthF Temperature F Thermal Cond., Vap. Btu/fthF Vapor lb/h Viscosity, Liquid cP Mol. Wt. Viscosity, Vapor cP Liquid lb/h Non-Condensables Latent Heat Btu/lb lb/h Pour/Freeze Point F Mol. Wt. Dew/Bubble Point F Steam lb/h Operating Pressure, Inlet psig Water lb/h Min. Fluid Vaporized or Condensed lb/h Velocity fps X Max. psi DP, Clean (Allow./Calc.) Steam Condensed lb/h Min. Fouling Resistance Liquid Specific Gravity ft2hF/Btu PERFORMANCE DATA - AIR SIDE Air Quantity, Total lb/h ft Above Sea Level scfm Plant Altitude Air Quantity per Fan lb/h F scfm Temperature In (Design Dry Bulb) Velocity Min. Temperature Out F X Max. Face Velocity std fps Mass Velocity (Net Free Area) F lb/hft2 Min. Design Ambient Temp. CONSTRUCTION AND MATERIALS Design Pressure psig Test Pressure psig Design Temperature F Section Header Tubes Size Type Material : 316 Stainless Steel No. per Bay Tube Rows Material Fabrication Type : 316 Stainless Steel Seamless No. of Passes Slope in./ft OD 1-1/2" in. Gage, B.W.G. : 18 Arrangement: Two Plug Material No./Bundle : 50 Length : Bundles in Series Parallel 40 ft Pitch : 1.25 in. Pattern : Rot. Square Bays in Series Parallel Gasket Material Corrosion Allowance 0.125 in. Tube Sheet Joint : Welded Bundle Frame: Miscellaneous Fins No. Size Connections Rating Facing Structural Mounting Inlet Type : Low-Finned Outlet Material : Surface Preparation Temperature OD in. Stock Thk. in. Pressure Fins/inch Des. Temp. Louvers Auto Manual F Code Requirements: ASME Sec. VIII, Para. 1 (1992) MECHANICAL EQUIPMENT Fan Driver Speed Reducer Mfr/Model No. Type Type : Gear box No./Bay HP/Fan Mfr/Model No. Mfr/Model No. Diameter No./Bay No./Bay ft Pitch Angle Blade Mat'l RPM HP/Driver RPM AGMA Rating HP Tip Speed Enclosure Ratio : fps Pitch Adj. Structure % Auto-Variable % Power v Ph Hz Support : Steam Coil? Air Recirculation Control : External - Over Side Yes No Air Failure Control Action: Fan Pitch Min. Max. Lockup Louvers Open Close Lockup Vibration Switches Req'd? Yes No Chemical Cleaning, etc. Plot Area * * Weight - Bundle * lb Shipping Weight lb Remarks 1. Items marked with an asterisk (*) to be completed by Vendor.
Rev 0
By ABC
Chk. DEF
Appr. XYZ
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Sheet
1 of 1
Corporation
1 Service: 2 Site:
Project No.
Equipment No. Lean MEA Solution Cooler Unit Km 8, Avda. Venezuela; Lima, Peru German Huanuco P.O. No. Manufacturer: Model Mfr Ref. No. 3 * * * 4 TEMA Size, Type: 5 Surface/Unit: 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 P&ID No.: Fluid Allocation Fluid Circulated Total Fluid Entering Vapor (In/Out) Liquid Steam Non-Condensables Fluid Vaporized or Condensed Steam Condensed Temperature Density, Specific Gravity Viscosity Vapor Molecular Weight Specific Heat Thermal Conductivity Latent Heat Operating Pressure, Inlet Velocity Max. Min. Pressure Drop, Clean (Allow./Calc.) Fouling Resistance Heat Exchanged Transfer Rate, Service
ft2
Gross
Horiz.
Connected in
Series
One
PERFORMANCE OF ONE UNIT SHELL SIDE lb/h lb/h lb/h lb/h lb/h lb/h lb/h F cP
TUBE SIDE
Btu/lbF Btu/hftF Btu/lb psig fps psi ft2hF/Btu Btu/h Log MTD (Uncorrected) F Log MTD (Corrected) * * Btu/ft2hF . Transfer Rate, Clean CONSTRUCTION AND MATERIALS SHELL SIDE TUBE SIDE Sketch (Bundle, Nozzle Orientation)
F Btu/ft2hF .
Design Pressure psig Test Pressure psig Design Temperature F Number of Passes per Shell In Connections Out Size & Rating Intermediate * 0.75 16 BWG or 30 Tubes: Type Number OD in. in. X Min. 45 60 90 Av. Wall 0.9375 in. Flow Pattern (circle one) Tube Length in. Tube Pitch * * Rolled and welded Shell: ID in. OD in. Tube-to-Tubesheet Joint : * * * Baffles - Cross: Type Spacing in. % Cut on Area X Diam. Baffles - Long: Perm. Removable Seal Type: Bypass Seal: * * Inlet Nozzle lb/ftsec Bundle Entrance lb/ftsec Bundle Exit lb/ftsec * rv2: Expansion Joint? Yes Type: Impingement Protection? No X No X Yes PART THK, in. C.A., in. PART THK, in. C.A., in. MATERIAL MATERIAL Stnless Steel 14 BWG Min Floating Tubesheet Carbon Steel 0.0625 * None Tubes Carbon Steel Fixed Tubesheet Carbon Steel 0.0625 * None Shell Carbon Steel Tube Supports Carbon Steel None * 0.125 Shell Cover Carbon Steel Cross Baffles Stnless Steel None * 0.125 Channel Carbon Steel Long Baffle Carbon Steel None * None Channel Cover Carbon Steel Gaskets Carbon Steel None None Fltg Head Cover User Spec.: Stress Relieved (Mark "SR') and/or Radiographed (Mark 'XR') Parts Code Requirements: Stamp? No TEMA Class: ASME Sec. VIII, Para. 1 (1992) X Yes * * * Weights: Shell lb Filled with Water lb Bundle lb Remarks: 1. Items marked with an asterisk (*) to be completed by Vendor.
Rev 0
Date
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Sheet
1 of 1
Corporation
1 Service: 2 Location 3 Manufacturer 4 Size, Type 5 Surface/Unit 6 P&ID No. 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 Fluid Allocation Fluid Circulated Total Fluid Entering Vapor (In/Out) Liquid Steam Non-Condensables Fluid Vaporized or Condensed Steam Condensed Temperature Density, Specific Gravity Viscosity Vapor Molecular Weight Specific Heat Thermal Conductivity Latent Heat Operating Pressure, Inlet Velocity Min. X Max. Pressure Drop, Clean (Allow./Calc.) Fouling Resistance 3,097,238 Heat Exchanged Transfer Rate, Service Allocation Design Pressure psig Test Pressure psig Design Temperature F Number of Passes per Frame Corrosion Allowance in. Connections Size & Rating
Project No.
1234567
Cooling Water Exchanger Unit Barbados, W. I. Tuffy Forbes Mfr Ref. No. Model * * Frames/Unit *-* One Connected in Surface/Frame * ft2 Effective
Plot Plan No. PERFORMANCE OF ONE UNIT HOT SIDE lb/h lb/h lb/h lb/h lb/h lb/h lb/h F cP Btu/lbF Btu/hftF Btu/lb psig fps psi
*
Single
One
Gross
31,500 ---31,500 ------------235 0.907 0.54 ---0.867 0.178 ---75 8.0 10 * 10 ---31,500 ------------120 0.929 13.7 ---0.843 0.160 ---206,483 ------------90 0.995 0.76 ---1.0 0.358
0.001 0.003 ft2hF/Btu Btu/h Log MTD (Uncorrected) 157.0 F Log MTD (Corrected) Transfer Rate, Clean * * Btu/ft2hF CONSTRUCTION AND MATERIALS HOT SIDE COLD SIDE Sketch (Frame, Nozzle Orientation) 125 Code 300 * None 6" 125# FF 6" 125# FF ----
In Out Intermediate lb/fts rv2, Inlet/Outlet Impingement Protection? Yes No. of Plates Frame Capacity (Max. No. of Plates) PART THK, in. C.A., in. MATERIAL Plates Stnless Steel 16 BWG min. 0.03125 Plate Gaskets Carbon Steel * 0.03125 End Cover Carbon Steel * 0.03125
150 Code 300 Two 0.0625 3" 150# RF 3" 150# RF ----
MATERIAL
THK, in.
C.A., in.
Carbon Steel
0.03125
Stress Relieved (Mark "SR') and/or Radiographed (Mark 'XR') Parts OSHA Type Protective Shroud? Yes Material: Carbon Steel Insulation: Cleaning: Painting: Code Requirements: Stamp? ASME Sec. VIII, Para. 1 (1992) Yes Client Spec.: Weights: Empty Frame * Remarks 1. Items marked with an asterisk (*) to be completed by Vendor.
lb
Rev 0
By ArtM
Chk. DEF
Appr. XYZ
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Sheet
1 of 1
Corporation
1 Service: 2 Site: 3 Manufacturer 4 P&ID No. 5 6 Position 7 Shell Diameter 8 Shell Length 9 Internal Pressure 10 Temperature (Min/Norm/Max) 11 Nominal Volume 13
Project No.
Equipment No. Filter Feed Tank Unit P.O. No. Belle Glade, Florida Furfural Model Mfr Ref. No. * * * Plot Plan No. Other Ref. Dwg No. PID-01-2084 PLT-03-2049 Horizontal ID PROCESS (OPERATING) DATA Top X Vertical Bottom
V - 41
No. Req'd
One
Note 2
VESSEL SKETCH
TL-TL
X OD X S-S
gal Total Volume 3,000 12 Fluid Contained Aqueous Amine Sol'ns Specific Gravity Vapor Pressure @ Max. Ambient Temperature 14 Process Contaminants 15 Service is 16 17 Component 18 Shell & Heads 19 Internals 20 21 Supports 22 23 24 Des. Press. @ Top 25 System PSV Set @ 26 Des. Temperature 27 Vessel Support(s) 28 29 Fireproofing MECHANICAL DESIGN
P B O A H K
Q D C
E
Note 4
L
8'-0" OD
X Cyclic
X Weld-in
G J
4 Legs (min.)
5 100
Skirt Other
N/A psig top of vessel -20 F Minimum Temp. F Lugs Saddles X Legs
ft Above Grade in.
6'-11"
1 1
Vortex Breaker
85
% Inspection Req'd? NOZZLES/CONNECTIONS Qty 1 1 1 1 Size 2" 1" 1" 1" 1" 1" 1" 6" 2" 2" 4" 1" 3" 3" 4" 4" 1"
X Yes Rating 150 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb 300 lb
No Facing RF LJ RF RF RF RF RF RF LJ RF LJ RF RF RF RF RF RF
Mark Service A Liquid Inlet w/Dip Tube B C D E F G H J K L M N O P Q Liquid Inlet w/Dip Tube N2 Pad Vent Fill Connection (Note 4)
1 Agit'r Opn'g w/Reinf. Pad (Note 3) 1 Manhole w/Davit 1 Relief Valve Level Indicator (DP Cell) Level Indicator (Equal. Conn.) Liquid Inlet Temp. Indicator Pump Suction Light (Future) Sight Glass (Future) Spare 1 1 1 1 1 1 1 1 1
Specify Operating Levels Above Btm or BTL LCH HLL LAH NLL LAL LLL LCL Weights: Vessel Only Operating Weight
Standard Displacer Ranges are: 14" 24" 32" 45" Special Design Over 45"
*
lb
lb
Internals
Full of Water
* *
lb lb
53 Remarks: 1. Items marked with an asterisk (*) to be completed by Vendor. 2. Ref. set of detail dwgs for existing V - 41 (circa 1969). 3. Agitator supplied by Owner; conn. details on ref. dwgs. 54 55 4. Nozzle 'E': Tube Turn 12" T-Bolt hinged closure. Rev 0 Date 30-Sep-00 Description For Inquiry By ArtM Chk. DEF Appr. XYZ Rev Date Description By Chk. Appr.
Rev. No.
Montemayor
Sheet
1 of 1
M
Montemayor Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Assoc. Equip./Service 6 7 Fluid Name 8 Temp.,
Sheet
of
Perros Bravos, N. L.
Min.
Phase(s) Operating
Liq
gpm
9 Liq. SG @ 60 oF SG @ Op. T Vapor MW 10 Critical Press., PC Op'g Viscosity, m 11 Flow, Min. Norm. 12 13 14 15 16 17 18 Manufacturer 20 21 22 23 24 25 26 27 28 29 Bonnet/Body 30 Plug/Ball/Disk 31 Cage/Guide 32 33 Type 12-Mar-00 34 Manufacturer 35 36 37 38 39 40 41 Type Instrument Form No. Automatic Valves 42 Manufacturer 19 Trim Characteristic
psia
cP
Max. Capacity Upstream Pressure @ Flow psig Downstream Pressure @ Flow psig Fluid Density at Inlet T&P, Flow lb/ft3 Valve CV @ Flow (Calculated) Fail Position Maximum Closed DP Model Flow Direction Bal./Unbal. Body Size Port Size Trim Size Stroke Valve Percent Open Actual CV @ % Open End Connections (Size, Rating, Facing) Bonnet Type Number of Ports Lube & Isolating Valve (check) Lube Packing Type Packing Material Liner Seat/Seat Ring Stem
psi
Open
RF Two
Graphite Impreg.
RF Two
Graphite Impreg.
Ring-joint Four
Graphite
Diaphragm, pneumatic
Hydraulic Piston On-off Side, Left-hand psig psig psig psig psig psig None Increases Gauges Pneumatic Square Root By-pass
Model Service Size Eff. Area, in.2 Spring Action Handwheel Pos., Orient. Max. Allow. Press. Min. Req'd Press. Avail. Air Supply Press., Max. Min. Travel starts @ Rated Travel @
Open
Modulating Modulating Top, Left-hand Close Top, Right-hand psig psig psig psig psig psig psig psig psig psig psig psig POSITIONER Single-acting Double-acting Linear Decreases Square Root By-pass Gauges By-pass SWITCHES Mechanical
Date
Open
Rev.
Cam
AIR SET Filter Gauge psig Filter Gauge SPECIALS/ACCESSORIES/TESTS Class I Group A Div. 1 Class II Group C Div. 1 psig Class I psig Class II psig psig Filter Gauge
The Recycle Gas working fluid is a binary mixture of 15% vol NH3 + 85% vol H2 (60 % wt NH3 + 40 % wt H2) Two control valves are required for each of the two services. Date Description By Chk. Appr. Rev Date Description By Chk. Appr.
Rev
Rev. No.
Corporation
1 Service 2 Site: 3 Manufacturer 4 P&ID No. 5 6 Gas Handled :
Project No.
1234567 CF - 100
No. Req'd
Political Hot Air Unit Kingston, Jamaica Alf Newton Model Mfr Ref. No. * * Plot Plan No. PID-01-0000 PLT-03-0000
OPERATING CONDITIONS Intermittent for lb/h or lb/h or in. WC Inlet Temp. in. WC Disch. Temp. Compr. (Z) at Inlet
*
Other Ref. Dwg No. PERFORMANCE
One
7 Service is Continuous 8 Capacity, Normal 9 Capacity, Design 10 Inlet Pressure 11 Disch. Pressure 12 Gas Mol. Wt. 13 Cp/Cv at Inlet 14 Corrosion/Erosion Caused By 15 Dust Present? 16 17 18 19 20 Location 21 Ambient Temp. 22 Max. Relative Humidity 23 Electrical Area Classification 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Coupling(s) Flexible Fast/Falk Guard Sparkproof Case Cast Iron Steel Aluminum 316SS Concentration Solids are Abrasive No
Manufacturer's Proposal Curve No. hrs/day Type Centrifugal Axial 3600 SCFM RPM No. Stages SCFM Inlet Size/Rating F Disch. Size/Rating F Case Design Press. Relief Valve No. By Mfr Rotation (viewed from Cplg end) Packing, Type: By Customer
Vane
% Side Side F
psig; Design Temp. Located @ Set @ CW No. of Rings Mfr by Driver CCW
m
Sticky
Type: Elev.
Furnish Gear
Mount RPM
Outdoors F Max.
97
ft ASL
F Min. Other
MECHANICAL DETAILS AND MATERIALS OF CONSTRUCTION Rotor(s) Aluminum Alloy Steel Cast Steel 316SS Bearing Lubrication Oil Grease Shaft Sleeve Stellited 420SS None Lantern Ring Bronze Cast Iron Steel None Yes No Baseplate Mat'l Cast Iron Fabricated Steel lb Driver Wt. Packing Gland Bronze Cast Iron Steel Steel 316SS Shaft Bearings Ball Sleeve Roller Gears Steel V-Belt Drive V-Belt Static Conductor Guard Sparkproof Water Cooling Seal Bearing None
38 Common Baseplate and Driver by Mfr? 39 Baseplate Dimensions 40 41 42 43 44 45 46 47 48 49 50 51 52 Rev 0 Date Description
Approx. Wt., Blower & Base PROCESS CONTROL SKETCH (Incl. Scope of Supply
lb
By ABC
Chk. DEF
Appr. XYZ
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Sheet
1 of 2
Montemayor
Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Service or Associated Equipment 6 7 Fluid Name and Phase (l, v, g or 2 ) 8 Flow, Min. 9 Temp., Min. 10 Press., Min. 11 Mol. Wt.
Sheet
of
Huevos Rancios
P.O. No.
SERVICE CONDITIONS Nominal Max. units Max. gpm F psig lb/min F psig F psig
Nominal
Nominal Max. CP/CV Compress. Factor @ Op'g T&P Max. N N Material Y Y Nominal
cP N N Y Y
SSU N N Y Y
Size Range Size Range Liner Material Manufacturer Plate Type Plate Bore Sized for Bore Diam., d Pipe ID, D
% by volume % by weight Schedule Insulation Thk, Type ORIFICE PLATE AND FLANGE SPECIFICATIONS Model Material Design Std Thickness Units b = d/D Rating Location Material Vent (top) Drain (btm) Vent (top) Drain (btm) Vent (top) Drain (btm) Material in. in. in. in. in. in.
29 30 31 5-May-99 32 33 34
Date
METER SELECTION, MEASUREMENT PARAMETERS Model Seal Sp. Gr. @ 60F Static Units Chart Multiplier INSTALLATION, INTERFACE SPECIFICATIONS Class Hi Other: Min. Range Units feet feet feet Gr Lo Div Fault Class Hi Other: Gr Lo Div Fault Class Hi Other: Gr Lo Div Fault Housing Requirements
35 Manufacturer Rev. 0 36 Meter Type 37 Range: Diff. (Dry) 38 Chart or Scale Range Instrument Form No. 39 Other: 40 41 Area Classification 42 Output Units 43 44
Switches/Alarms
45 Totalizer (check)
Rev
Date
Description
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Service or Associated Equipment 6 7 Fluid Name (l, v, g or 2 ) 8 Flow, Min. 9 Temp., Min. 10 Press., Min. 11 Fluid Density @ 12 Viscosity, Min.
Sheet
of
Chiclayo, Peru
Cayalti
P.O. No.
SERVICE CONDITIONS Liq units Max. Max. Op'g T&P Max. N N Material Y Y gpm F psig lb/ft cP N N Y Y Vap gph F psig g/cc SSU N N Y Y Gas lb/min F psig lb/gal cSt Nominal Max.
None None *
A-Swt *
"
Hot *
1"
1" * * *
*
WN
125#
psig
FF *
F psi fps *
1" * * *
*
SW
300#
psig
FF *
F psi fps * %
2" * * *
*
SO
150#
psig
RF *
F psi fps * %
* *
*
* * *
g/cc
* *
*
* * *
g/cc
* *
*
* * *
g/cc
* *
* *
* *
% of Reading % of Reading
INSTALLATION, INTERFACE SPECIFICATIONS Housing Requirements Class II Gr 4 to 20 mA Hi Other: Min. Range Units feet feet feet Lo
A Div 2 NEMA-4X
Fault
Class II Gr
Pulse
Hi Other: Lo
B Div 1 NEMA-7
Fault
Class III Gr
Digital
Hi Other: Lo
C Div 1 NEMA-12
Fault
Switches/Alarms
38 Totalizer (check)
Rev
Date
Description
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Assoc. Equip./Service 6 7 Fluid Name (l, v, g or 2 ) 8 Flow, Min. 9 Temp., Min. 10 Press., Min.
Sheet
of
Piura, Peru
L'Air Liquide
P.O. No.
SERVICE CONDITIONS Liq units Max. Max. @ Op'g T&P Max. N N Material Y Y gpm
o
Gas gpm
o
2-Ph gpm
o
Nominal
Max.
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP
Hot *
1"
None None
Cold
1"
* * *
*
psig
* * *
F psi fps *
psig
F psi fps %
psig
F psi fps %
* *
*
Nominal
Max. Flow
* * g/cc
* %
g/cc
g/cc
Hi Other:
Lo
Fault
Hi Other:
Lo
Fault
Hi Other:
Lo
Fault
38 Totalizer (check)
feet
feet
feet
Rev
Date
Description
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Assoc. Equip./Service 6 7 Fluid Name (l, v, g or 2 ) 8 Flow, Min. 9 Temp., Min. 10 Press., Min.
Sheet
of
Caracas, Venezuela
Rbt. Humphries
P.O. No.
SERVICE CONDITIONS Nominal Max. units Max. Max. @ Op'g T&P Max. N N Material Y Y gpm
o
gpm
o
gpm
o
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP
None None *
Hot
None
A-Swt
1"
* * *
*
psig
* * *
F psi fps * %
psig
F psi fps %
psig
F psi fps %
* *
*
Nominal
Max. Flow
* *
*
g/cc
* %
g/cc % of % of
g/cc % of % of
A Div 2 I Gr NEMA-4X 4 to 20 mA
Lo Fault
Class II
Gr B
Div 1
Class III Gr C
Div 1
NEMA-7 Pulse
Hi Other: Lo Fault Hi Other: feet
NEMA-4 Digital
Lo Fault
Hi Other:
38 Totalizer (check)
feet
feet
Rev
Date
Description
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Assoc. Equip./Service 6 7 Fluid Name (l, v, g or 2 ) 8 Flow, Min. 9 Temp., Min. 10 Press., Min.
Sheet
of
Arica, Chile
Air Products
P.O. No.
SERVICE CONDITIONS Nominal Max. units Max. Max. @ Op'g T&P Max. N N Material FLOWMETER SELECTION, MEASUREMENT PARAMETERS Model * Y Y gpm
o
gpm
o
gpm
o
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP
* * *
*
psig
* * *
psi fps *
psig
F psi fps
psig
F psi fps
* *
*
Nominal
Max. Flow
* *
*
g/cc
* *
% %
* *
*
g/cc % of % of
* *
% %
* *
*
g/cc % of % of
* *
% %
A Div 2 NEMA-4X 4 to 20 mA
Lo Fault lb feet
Class
A I Gr NEMA-7 Pulse
Lo
Div 1
Class
C I Gr NEMA-4 Pulse
Lo
Div 1
Hi Other:
Hi Other:
Fault kg feet
Hi Other:
38 Totalizer (check)
Rev
Date
Description
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Assoc. Equip./Service 6 7 Fluid Name (l, v, g or 2 ) 8 Flow, Min. 9 Temp., Min. 10 Press., Min.
Sheet
of
La Paz, Bolivia
Pepe Mendietta
P.O. No.
SERVICE CONDITIONS Nominal Max. units Max. Max. @ Op'g T&P Max. N N Material FLOWMETER SELECTION, MEASUREMENT PARAMETERS Model * Y Y gpm
o
gpm
o
gpm
o
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP N N Y Y
psig lb/ft3 cP
* * *
*
psig
* * *
F psi fps *
psig
F psi fps %
psig
F psi fps %
* *
*
Nominal
Max. Flow
* *
*
g/cc % of % of
* %
g/cc % of % of
g/cc % of % of
A Div 1 I Gr NEMA-12 4 to 20 mA
Lo Fault lb feet
Class II Gr
B NEMA-4 Pulse
Lo
Div 2
Class III Gr
C NEMA-7 Digital
Lo
Div 2
Hi Other:
Hi Other:
Fault kg feet
Hi Other:
38 Totalizer (check)
Rev
Date
Description
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.
Montemayor
Corporation
1 Location 2 Tag Number 3 P&ID Number 4 Line Number 5 Assoc. Equip./Service 6 7 Fluid Name (l, v, g or 2 ) 8 Flow, Min. 9 Temp., Min. 10 Press., Min.
Sheet
1 of
Victoria, TX
P.O. No.
SERVICE CONDITIONS Liq units Max. Max. @ Op'g T&P Max. N N Material FLOWMETER SELECTION, MEASUREMENT PARAMETERS Model * Y Y gpm oC kPa lb/ft cP N N Y Y Gas lb/min oC psia lb/ft SSU N N Y Y 2-Ph lb/min oC atm lb/ft cSt Nominal Max.
* * *
*
psig
* * *
F psi fps * %
psig
F psi fps %
psig
F psi fps %
* *
*
Nominal
Max. Flow
* *
*
g/cc
* *
g/cc
g/cc
A Div 1 I Gr NEMA-4X 4 to 20 mA
Lo Fault lb feet
Class II Gr
B NEMA-7 Pulse
Lo
Div 1
Class III Gr
C NEMA-4 Digital
Lo
Div 2
Hi Other:
Hi Other:
Fault kg feet
Hi Other:
38 Totalizer (check)
Rev
Date
Description
By
Chk.
Appr.
Rev
Date
Description
By
Chk.
Appr.
Rev. No.