KBPC 240d
KBPC 240d
KBPC 240d
KBPC-240D
PENTA-DRIVE NEMA-4X, IP-65
TM
Variable Speed-Torque SCR DC Motor Control for Shunt Wound and PM Motors
ONE MODEL COVERS: 1/50 1 Hp @ 115 VAC 50/60 Hz 1/25 2 Hp @ 230 VAC 50/60 Hz Washdown and Watertight for Indoor and Outdoor Use STANDARD FEATURES
Electronic Overload Protection Built-in Armature Fusingv LEDs for Power On, Overload and Stop Electronic Start-Stop
v
DESCRIPTION The KBPC Series NEMA-4X (IP-65) SCR DC Motor Speed and Torque Control is designed for applications requiring washdown watertight integrity. Its housing is ruggedly constructed of die cast aluminum which is protected with an acrylic coating for the ultimate in corrosion resistance. All switches are sealed with rubber boots and the main speed potentiometer contains a shaft seal. The KBPC state-of-the-art electronics include short circuit and transient protection to provide the ultimate in reliability. Electronics overload protection is also provided which prevents motor burnout and demagnetization of PM motors. The control can be operated in either the speed or torque mode via a jumper selection. The current range, which is also jumper selectable, eliminates the necessity for calibration of IR compensation and current limit for most applications. The KBPC also contains jumper selections for AC line voltage (230/115), DC armature voltage (180/90) and feedback type (armature/tachometer). Standard features include Armature Fusing, Electronic Start/Stop and LED Indicator Array for Power On, Stop and Overload. Although the KBPC is factory set for most applications, a variety of trimpots allows adjustment of the following parameters: MIN and MAX speed, Acceleration, Deceleration, Current Limit, IR Comp, and Timed Current Limit. The drive offers the ultimate in flexibility with the availability of several customer installed options. These include: Anti Plug Reversing Module, Forward-Brake-Reverse with Hesitation Feature, Run Stop-Jog, On/Off AC Line Switch, Input Signal Isolation, and Electronic Potentiometer. A complete instruction manual is included.
TRIMPOT ADJUSTMENTS
Minimum Speed (MIN) Current Limit (CL) Acceleration (ACCEL) Timed Current Limit (TCL)
v
Maximum Speed (MAX) IR Compensation (IR) Deceleration (DECEL) Jog Speed (JOG)v
OPTIONAL FEATURES
Forward-Brake-Reverse Switch with hesitation feature (P/N 9339). Includes switch and prewired dynamic brake resistor. Run-Stop-Jog Switch (P/N 9340) Signal Isolator, KBSI-240D (P/N 9431) On/Off AC Line Switch (P/N 9341) White Case (FDA) (P/N 9342) Electronic Pot, KBEP-240D (P/N 9108) Anti Plug Reversing Module (P/N 9378) Auto/Manual Kit (P/N 9377)
* CE Compliance Requires KBRF-200A RFI Filter
TM
40
Rev.______(A_______)
SPECIFICATIONS
Parameter Specification Factory Setting Parameter Specification Factory Setting
AC Line Voltage Regulation (% Base Speed).............. 0.5 .............. Current Ranges (ADC) ........................................ 2.5, 5, 7.5, 10 ...... 10 ACCEL and DECEL Ranges (Seconds) .................... 0.115 ............ 1 MIN SPEED Range (% Base Speed) ........................ 030 .............. 0 MAX SPEED Range (% Base Speed) ...................... 60140 .......... 100 IR COMP Range at 115 VAC Line (VDC) .................. 015 .............. 4 IR COMP Range at 230 VAC Line (VDC) .................. 030 .............. 8 CL Range (% Range Setting) .................................... 0200 ............ 150 TIMED CL Range (Seconds) .................................... 0.515 ............ 7 Voltage Following Linearity (% Base Speed) .............. 0.5 .............. AC Line Voltage (VAC 10%, 50/60 Hz)................ 115 or 230 ........ 230
Horsepower Range at 115 VAC Line (Hp) [kw].... 1/501, [.015-.75].... Horsepower Range at 230 VAC Line (Hp) [kw] .... 1/252, [.031.5].... Armature Voltage Range at 115 VAC Line (VDC) .......... 0130*............ Armature Voltage Range at 230 VAC Line (VDC) .......... 0220* .......... 180 Field Voltage at 115 VAC Line (VDC) .......................... 100/50** .......... Field Voltage at 230 VAC Line (VDC) .......................... 200/100**.......... Ambient Temperature Range (C) .................................. 050.............. Speed Range (Ratio)........................................................ 50:1 .............. Load Regulation, Arm. Feedback(% Base Speed) ............ 1 .............. Load Regulation, Tach. Feedback (% Set Speed).............. 1 ..............
NOTES: *Maximum recommended output voltage is 90 VDC for 115 VAC and 180 VDC for 230 VAC. Exceeding these output voltages may cause a reduction in load regulation performance. **For shunt wound motor with lower voltage field, use L1 and F1 connection.
ELECTRICAL RATINGS
Model Number KB Part Number AC Line Voltage (VAC) 10% 50/60 Hz Motor Voltage (VDC) Max. AC Load Current (RMS Amps) Max. DC Load Current (DC Amps) Maximum Horsepower Hp, (KW) Field Voltage** (Volts DC) Terminals F1, F2 Terminals F1, L1
15.0 15.0
10.2 10.2
1, (.75) 2, (1.5)
100 200
50 100
*Stepdown operation (90 VDC motors with 230 VAC input) can cause a reduction in motor performance. **Shunt motors only
MECHANICAL SPECIFICATIONS
5.886 (149.50) _ 0.25" MOUNTING SCREWS 5.472 (139.00)
INCHES [mm]
CONNECTION DIAGRAM
LED BOARD
MAIN BOARD
ON
2.736 (69.50)
STOP
CL
YGRB
NTCL
J7
CL
ON
STOP
OL
IR
STOP JOG P3
DECEL ACCEL
PENTA-DRIVE
TM
P2 P1 CONN1 T+
MIN MAX
40 30
50
60 70 80 90
TACH INPUT
T50V 20/30V 7V 180V 90V T J3 R69 L1B T1 J9A L1A J2A A1B J8A J2B 230V 115V 115V 230V
20 10 0
FWD BRK REV
J6
100
F1 ARM FUSE
NEMA-IV / IP-65
A1A
F1 F2
CONN2
START
RUN
F1 F2 TB2
STOP JOG
TM
A1
A2
L1
L2
+ FIELD
MAXIMUM DEPTH 5.000 (127.00)
FIELD CONNECTION USED ON SHUNT MOTORS ONLY. MOTORS WITH HALF VOLTAGE FIELD USE F1 AND L1. FIELD (*) ARMATURE
AC LINE INPUT
DWG#: C2800-1-00413
DWG#: B2800-2-00359H
KB ELECTRONICS, INC.