1. Zurn Light Commercial Grease lnterceptors hub couplings. . ij"'3
l
should be installed as close as possible to the 6. Outlet piping should be connected to the : tt
'. .l,r
fixture being served. Always installwhere there sanitary drain, and pipe size should be equal
is easy access for cover removal and cleaning. to or larger than the inlet piping. Outlet pipe
2. Aflow control must be installed as close as should also be vented so the interceptor is not
possible to the underside of the fixture. The siphoned.
floweontrolmusfbe-instatled with the ventor{air-in- 7. Solid waste should ngF€o into an interceptor.
take)on the downsiream side of the orifice plate. The Food grinderwaste and'.bther solids should
vent connection is positioned to the top of the flow be captured in ihe sink or by a solids interceptor
control fitting and piped upward higher than source before reaching the grease interceptor.
of water, or to building vent system
3. lt is recommended that a cleanout iee be in-
stalled before the flow control to access the
flow control orifice and clear debris.
4. The cleanout plug should be installed overthe
outlet of the interceptor.
5. The interceptor isto be installed using no-
ZABfiT
LIGHT
COMMERCIAL
MATIWENATICE
General Considerations
To obtain optimum operating efficiency of a properly sized and installed PDI certified grease interceptor,
a regular schedule of maintenance must be adhered to.
Cleaning
All grease interceptors must be cleaned regularly. The frequency of grease removal is dependent upon the
capacityoftheinterceptorandthequantityofgreaseinwastewater. Checkinterceptordailyuntilagrease
level of 2" to 3" has been obtained (cleaning level). When the grease removal interval has been determined
for a specific installation, regularcleaning at that interval is necessary to maintain the rated efficiency of the
interceptor. Aftertheaccumulatedgreaseandwastematerialhasbeenremoved,theinterceptorshouldbe
thoroughly checked to make certain the inlet, outlet, and air relief ports are clear of obstructions.