ITCC in Riyadh Residential Complex J10-13300 10165-1 Toilet Partitions
ITCC in Riyadh Residential Complex J10-13300 10165-1 Toilet Partitions
Toilet partitions and the related accessories as shown on Drawings and as specified herein.
REFERENCES A. ASTM - American Society for Testing and Materials ASTM E 84 - Surface Burning Characteristics of Building Materials B. UL - Underwriters Laboratory UL 723 - Surface Burning Characteristics of Building Materials C. NFPA - National Fire Protection Association NFPA 255 - Surface Burning Characteristics of Building Materials D. NEMA - National Electrical Manufacturers Association NEMA LD-1 - Standard Publication for Laminated Thermosetting Decorative Sheets NEMA LD-3 - High Pressure Decorative Laminate
1.3.
SUBMITTALS A. Submit the following for the Engineer Representative review and approval: 1. 2. Product data for physical characteristics, durability, resistance to fading, and flame spread characteristics for type of partition and accessories specified. Shop drawings showing location and extent of partitions. Include plans, elevations, large-scale details of anchorages, and accessory items. Indicate unit conditions at openings, typical and special details, and location and installation requirements for hardware. Certificates of compliance signed by manufacturer of partitions certifying that the products comply with the specified requirements.
3. 1.4.
TRANSPORTATION, HANDLING AND STORAGE A. Deliver materials to site in Manufacturer's original factory wrappings and containers, clearly labeled for identification of Manufacturer, brand name and contents.
B.
Store panels only on edge, blocked off ground to prevent sagging and warping in
10165-1 Toilet Partitions
original undamaged packages and containers, inside a well-ventilated area protected from weather, moisture, soiling, extreme temperatures, and humidity. 1.5. WARRANTY A. Submit written guarantee signed by the Manufacturer, Installer and Contractor, agreeing to replace partitions which fail in materials or workmanship within 1 year of date of substantial handing over.
1.6.
QUALITY ASSURANCE A. B. Single-Source Responsibility: Obtain partitions, mounting accessories all from one source from a single Manufacturer. hardware and
Fire Performance: Partitions shall have flame spread of 25 or less and smoke development of 450 or less when tested in accordance with ASTM E 84.
PART 2 - PRODUCTS 2.1 MATERIALS A. Toilet Partitions: Floor-supported type, constructed of 12 mm thick solid phenolic core consisting of multiple sheets of resin-impregnated kraft paper and matte finish colored melamine facing sheets fused together at high temperature and pressure to produce solid phenolic doors, stiles, pilasters and panels of sizes as shown on Drawings. Color shall be as selected and approved by the Engineer from the manufacturer standard range of colors. Mounting Brackets: Provide manufacturer standard brackets for panel assembly as well as connection to adjacent walls. Brackets shall be stainless steel, type 302 or 304 in accordance with ASTM A 167, satin finished. Door Hardware and Accessories: Heavy-duty grade, stainless steel, type shall be as recommended by the manufacturer and approved by the Engineer. Anchorage and Fasteners: As recommended by manufacturer and in accordance with the following: 1. 2. For Concealed Anchors: provide hot-dip galvanized steel or any other rustresistant protective-coated steel. For Exposed Anchors and Fasteners: Provide stainless steel, type 304, ASTM A 167. Theft-resistant (one way) type heads and nuts shall be provided for exposed anchorage.
B.
C. D.
2.2
FABRICATION A. General: Provide standard doors, panels and pilasters fabricated for the partition system. Panels and Door Dimensions: As indicated on Drawings. Provide floor-supported pilasters to secure structural carrying members. Provide
10165-2 Toilet Partitions
B. C.
anchorage devices complete with standard hex nuts, lock washers, threaded rods and leveling adjustment nuts as required. D. Manufacturer's Standard hardware for each compartment in the partition system shall be furnished as follows: 1. 2. 3. Hinges: Cut-out inset type. Latch and Keeper: Surface-mounted latch unit. Coat Hook and Bumper: Manufacturer's Standard unit as a combined hookbumper.
PART 3 - EXECUTION 3.1 EXAMINATION A. Examine areas and conditions where toilet partitions and related items are to be installed and remedy any conditions affecting proper installation and completion of work. Proceed with installation after unsatisfactory conditions have been corrected.
3.2
INSTALLATION B. C. General: Install partitions rigid, straight, plumb and leveled with panels laid out as indicated on Drawings. Provide maximum clearance of 1/2 inch between stiles and panels, 1 inch between panels and walls. Secure panels to walls stirrup brackets using 2 brackets as a minimum. Locate holes for anchorage of wall brackets at tile joints. Anchor pilasters to floor using Manufacturer's Standard devices. Adjust bottom of door with bottom of pilasters when doors are in the closed position. Hardware shall be adjusted and lubricated for proper operation after installation as follows: 1. 2. Hinges for In-Swing Doors: Set on to hold open approximately 30 o from closed position when unlatched. Hinges for Out-Swing Doors: Set on to return to the fully closed position.
D. E.
3.3
CLEANING AND ADJUSTING A. B. Protect units so that there will be no indication of use or damage at the time of acceptance. Perform final adjustment to anchoring devices, door hardware, and other operating parts of the partition assembly just prior to final inspection. Clean partition surfaces and clean adjacent surfaces soiled by work of this section. Avoid use of abrasive cleaners or solutions containing corrosive solvents. Use cleaning materials recommended by the Manufacturer.
C.
10165-3
Toilet Partitions
D.
Replace damaged units that cannot be satisfactory field repaired as directed by the Engineer. END OF SECTION
10165-4
Toilet Partitions