SH 09 12 BPH X Service Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

ROOM AIR CONDITIONER

INDOOR UNIT
SH09BPH SH12BPH

OUTDOOR UNIT
SH09BPHX SH12BPHX

SERVICE
AIR CONDITIONER

Manual
CONTENTS 1. Product Specifications 2. Operating Instructions 3. Disassembly and Reassembly 4. Refrigerating Cycle Diagram 5. Set Up the Model Option 6. Troubleshooting 7. Exploded Views and Parts List 8. PCB Diagram 9. Wiring Diagram

1. Product Specifications
1-1 Table
Model Item Power Source Capacity Energy Efficiency Ratio Cooling Air Flow Moisture Removal Performance Noise Level Indoor Noise Level Outdoor Capacity Heating Energy Efficiency Ratio Air Flow Noise Level Indoor Noise Level Outdoor Available Voltage Range Running Amperes Cooling Power Input Power Factor Running Amperes Electrical Rating Heating Power Input Power Factor Starting Current Fuse Capacity Power Cord Cable-Connector Type Compressor Model Name Safety Devices Indoor Fan Motor Outdoor Refrigerant Tube Model Name Running Capacitor Model Name Running Capacitor EEV g mm mm kg kg Indoor room Cooling test Heating test DB27C / WB19C DB20C / WB15C Indoor unit : W x H x D Outdoor unit : W x H x D Indoor unit Outdoor unit Refrigerant to Charge (R410A) Dimension Weigth -V-Hz W BTU/h BTU/wh m /min
3

SH09BPH SH09BPHX 1-220/240-50 2,800(1,500~3,400) 9,500(5,100~11,600) 11.8(10.0~13.8) 5.5 1.5 34 53 3,200(1,500~4,500) 10,900(5,100~15,300) 13.6(10.2~14.6) 7.5 39 53 187~264 3.6(2.0~4.9) 800(370~1,150) 96.6(84.5~97.6) 4.0(1.8~6.5) 880(350~1,500) 95.6(81.8~98.6) 10 3.15 x 250 / 20 x 250 15 x 250 1.5 x 4 Single Rotary G4C090LU1ER 204CT YDK-204F8C-1 1.2F / 450V AMASS-020WTVB 1.7F / 450V UKV-18D11 1000 890 x 285 x 180 720 x 548 x 265 9 33.8 Outdoor room DB35C / WB24C DB 7C / WB 6C

SH12BPH SH12BPHX 1-220/240-50 3,500(1,500~4,000) 11,900(5,100~13,600) 10.9(10.2~13.8) 6.5 1.6 39 53 4,000(1,500~5,000) 13,600(5,100~17,000) 11.6(10.0~14.6) 8.3 42 53 187~264 4.8(2.0~5.9) 1,090(370~1,330) 98.0(82.3~98.7) 5.5(1.8~7.2) 1,170(350~1,700) 97.8(81.8~98.4) 10 3.15 x 250 / 20 x 250 15 x 250 1.5 x 4 Single Rotary G4C090LU1ER 204CT YDK-204F8C-1 1.2F / 450V SIC-52FV-D828-1 UKV-18D11 1000 890 x 285 x 180 720 x 548 x 265 9 33.8

\/h dBA W BTU/h BTU/wh m3/min dBA V A W % A W % A AxV AxV mm3 x G F x VAC F x VAC

Remark : Text condition

Samsung Electronics

1-2 Pressure Graph


s SH09BPH

10.5 10.0

Pressure (kgf/cm2g)

9.5 9.0 8.5 8.0 7.5 7.0 6.5 20 25 30 35 40 45

Outdoor Temp. (C)

s SH12BPH

10.5 10.0

Pressure (kgf/cm2g)

9.5 9.0 8.5 8.0 7.5 7.0 6.5 20 25 30 35 40 45

Outdoor Temp. (C)

Samsung Electronics

2. Operating Instructions
2-1 The Feature of Key in remote control
No NAMED OF KEY FUNCTION OF KEY
On/Off button. Press the button to stop or run the air conditioner.

(On/Off)

(UP) 2 (DOWN)

Temperature adjustment button(UP). To increase the temperature by the pressing the temperature button.

Temperature adjustment button(DOWN). To decrease the temperature by the pressing the temperature button.

Mode selection button. Each time you press this button Mode is changed in the following order

: Auto Mode : Cool Mode : Dry Mode

: Fan Only : Heat Mode

Fan speed adjustment button. Each time you press this button, FAN SPEED is changed in the following order. 4 Low Medium Automatic(rotated : High )

Swing button. It adjusts the airflow to upward and downward.

Turbo button. The air conditioner cools or heats the room as quickly as possible. After 30 minutes, the air conditioner is reset automatically to the previous mode.

Sleep button. The sleep timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a period of 6 hours.

Anion button. Press the button to generate ion from the air conditioner.

Samsung Electronics

Operating Instructions

No

NAMED OF KEY

FUNCTION OF KEY
On Timer button. The On Timer enables you to switch on the air conditioner automatically after a given period of time that is from 30 minutes to 24 hours. To set the operating time, press the time display. button one or more times until the required

10

Off Timer button. The Off Timer enables you to switch off the air conditioner automatically after a given period of time that is from 30 minutes to 24 hours. To set the operating time, press the time display. button one or more times until the required

11

Timer Set/Cancel button. After setting On Timer or Off Timer, press the And press the

button to set it completely.

button again to cancel On Timer or Off Timer set.

12

Digital On/Off button. If you want to turn off the display during operation press the

button.

Samsung Electronics

Operating Instructions

2-1-1 Name & Function of Key in remote control


1. AUTO MODE : In this mode, operation mode(COOL, HEAT) is selected automatically by the room temperature of initial operation.
Room Temp Tr 21C+T 21C +T>Tr Operation Type Cool Operation (Set Temp:24C+T) Heat Operation (Set Temp:22C+T)

4.

DRY MODE : Has 3 states, each determined by room temperature. The unit operates in DRY mode. *Compressor ON/OFF Time is controlled compulsorily (can not set up the fan speed, always breeze). *Protective function : Low temperature release. (Prevention against freeze) TURBO MODE : This mode is available in AUTO, COOL, HEAT, DRY, FAN MODE. When this button is pressed at first, the air conditioner is operated "powerful" state for 30 minutes regardless of the set temperature, room temperature. When this button is pressed again, or when the operating time is 30 minutes, turbo operation mode is canceled and returned to the previous mode. *But, if you press the TURBO button in DRY or FAN mode that is changed with AUTO mode automatically. SLEEP MODE : Sleep mode is available only in COOL or HEAT mode. The operation will stop after 6 hours. *In COOL mode : The setting temperature is automatically raised by 1C each 1hour When the temperature has been raised by total of 2C, that temperature is maintained. *In HEAT mode : The setting temperature is automatically dropped by 1C each 1hour. When the temperature has been dropped by total of 2C, that temperature is maintained. FAN SPEED : Manual (3 step), Auto (4 step) Fan speed automatically varies depending on both the difference between setting and the room temperature. COMPULSORY OPERATION : For operating the air conditioner without the remote control. *The air conditioner starts up in the most suitable mode for the room temperature:
Room Temperature Less than 21C 21C or above Operating Mode Heat Cool Temperature Setting 22C approx. 24C approx.

T= -1C, -2C, 0C, +1C, +2C T is controlled by setting temperature up/down key of remote control 2. COOL MODE : The unit operates according to the difference between the setting and room temperature. (18C~30C) HEAT MODE : The unit operates according to the difference between the setting and room temperature.(16C~30C) *Prevention against cold wind : In order to prevent the cool air from flowing out at the heat mode, the indoor fan does not operate or operates very slowly in the following cases. At this time, the indoor heat exchanger will be preheating. - For 3~5 minutes after the initial operation - For deicing operation - The operation of an indoor fan in accordance with the temperature of an indoor heat exchanger
The temperature of indoor heat exchanger below 28C 28C~below 34C 34C~below 40C above 40C Indoor fan speed off LL Speed L Speed Setting Speed

5.

3.

6.

7.

8. *High temperature release function : It is a function to detect an outdoor overload by the sensor of an indoor heat exchanger and to turn the outdoor fan or the compressor ON/OFF for safety. *Deice : Deicing operation is controlled by indoor unit's heat exchanger temperature and accumulating time of compressor's operation. Deice ends by sensing of the processing time by deice condition.

Samsung Electronics

Operating Instructions

9.

SWING : BLADE-H is rotated vertically by the stepping motor. *Swing Set : Press the button under the remote control is displayed on LCD the and the blades move up and down. If the one more time press the button, blades location is stop.

12. SELF DIAGNOSIS


Error Mode Indoor unit room temperature sensor error (open or short) Indoor unit heat exchanger temperature sensor error(open or short) Indoor FAN MOTOR error : Keep the RPM value 100 below for 15 seconds EEPROM error Error in option In case of No option set-up In case of option data error Communication error DISPLAY 7-SEGMENT Operation Off Operation On OFF E1 Remark

10. SETTING THE ON/OFF TIMER. : *ON TIMER : The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. *OFF TIMER : The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. 11. GENERATING ANION : The air conditioner can generate anion with an ionizer in the indoor unit.

OFF

E5

OFF

E3_01

OFF

06

OFF

09

EA_01

EA_01

13. BUZZER SOUND : Whenever the On/Off button is pressed or whenever change occurs to the condition which is set up or select, the compulsory operation mode, buzzer is sounded "beep".

Samsung Electronics

2-2 Replace PCB Model option


2-2-1 Replace PCB model option

Remove power cord

Replace the PCB module

Check the connection and plug in

No

Does all display lamp blink?

Replace another PCB

Yes

Refer to set up the Model option(15~17page)

Samsung Electronics

3. Disassembly and Reassembly


Stop operation of the air conditioner and remove the power cord before repairing the unit.

3-1 Indoor Unit


No 1 Parts Front Panel Procedure 1) Stop the air conditioner operation and block the main power. 2) Detach tape of Front Panel upper. Remark

3) Slide the lower Front Grille down, then disassemble it by pulling it forwards. 4) Open the upper Front Grille by pulling right and left sides of the Grille. 5) Take the left and right Filter out. 6) Loosen one of the right screw and detach the Terminal Cover. 7) Detach the thermistor from the Front Grille.

8) Loosen 5 fixing screws of Front Grille.

9) Pull the lower left and right of discharge softly for the outside cover to be pulled out.

Samsung Electronics

Disassembly and Reassembly

No

Parts

Procedure 10) At first, press the left and center hook of the back side of the Panel Grille with the thumb to remove the hook. And press the right of the upper side of the Panel Grille with the fingers. And then disassemble the Panel Grille.

Remark

Electrical Parts (Main PCB)

1) Take all the connector of PCB upper side out.(Including Power Cord) 2) Detach the outdoor unit connection wire from the Terminal Block. 3) If pulling the main PCB up, it will be taken out.

Tray Drain

1) Pull Tray Drain out from the Back Body.

Samsung Electronics

Disassembly and Reassembly

No 4

Parts Heat Exchanger

Procedure 1) Loosen 2 fixing earth screws of right side. 2) Detach the Connection Pipe. 3) Detach the Holder Pipe at the rear side. 4) Loosen 3 fixing screws of right and left side.

Remark

5) Detach the Heat Exchanger from the indoor unit.

Fan Motor & Cross Fan

1) Loosen 2 fixing screws and separate the Motor Holder. 2) Loosen 1 fixing screw of Fan Motor. (with a M3 wrench) 3) Detach the Fan Motor from the Fan.

4) Detach the Fan from the left Holder Bearing.

10

Samsung Electronics

3-2 Outdoor Unit


No 1 Parts Common Work Procedure 1) Loosen each 3 fixing screws on both right and left Cabinet-Side edge and a fixing screw on the Cabinet-Front lower to detach the Cabinet-Front. Remark

2) Loosen 1 fixing screws of the Cover-Valve.

3) Loosen 6 fixing screws of the Cabinet-Side RH.

4) Loosen 2 fixing screws of the Cabinet-Side LF.

Samsung Electronics

11

Disassembly and Reassembly

No 2

Parts Fan & Motor

Procedure 1) Detach the Nut Flange.(Turn counterclockwise because the screw is right-handed) 2) Detach the Fan. 3) Loosen 4 fixing screws to detach the Motor.

Remark

Heat Exchanger

1) Loosen 2 fixing screws on both sides. 2) Disassemble the pipe in both inlet and outlet with welding torch. 3) Detach the Heat Exchanger.

Compressor

1) Loosen the Terminal Cover nut to open the Terminal Cover. 2) Disassemble the cloth sound felt. 3) Disassemble the pipe in both inlet and outlet of the Compressor with welding torch. 4) Disassemble the pipe in both inlet and outlet of the Condenser with welding torch. 5) Loosen the 3 bolts at the bottom. 6) Detach the Compressor.

12

Samsung Electronics

4. Refrigerating Cycle Diagram

Indoor Unit

Outdoor Unit

Capillary tube T1 2-Way valve Liquid side EEV

Heat Exchanger (Evaporator)

Heat Exchanger (Evaporator)

T2 Gas side 3-Way valve

4-Way valve Cooling Compressor Heating Gas leak check point

Samsung Electronics

Propeller fan

Cross fan

13

5. Set Up the Model Option


5-1 Setting Option Setup Method

ex) Option No. :


Step 1 : Enter the Option Setup mode. 1st 2nd Take out the batteries of remote control. Press the temperature insert the battery again. button simultaneously and

3rd

Make sure the remocon display shown as

Step 2 : Enter the Option Setup mode and select your option according to the following procedure.

1
The default value is Otherwise, push the repeatedly. . button to . or

Every time you push the button, the display panel reads

2
Push the
3 2

button to set the display panel to

Every time you push the button, the display panel reads ... repeatedly.

1 4

3
Push the button to set the display panel to . Every time you push the button, the display panel reads ... repeatedly.
6

4
Push the button to set the display panel to . Every time you push the button, the display panel reads ... repeatedly.

5
Push the button to set the display panel to . Every time you push the button, the display panel reads ... repeatedly.

6
Setting is not required if you must a value which has a default.

Push the

button to set the display panel to

Every time you push the button, the display panel reads ... repeatedly.

14

Samsung Electronics

Set Up the Model Option

7
Press button, then the default value is .

8
Push the button to set the display panel to . Every time you push the button, the display panel reads ... repeatedly.
9 8

9
Push the
7 10

button to set the display panel to

Every time you push the button, the display panel reads ... repeatedly.

10
11 12

Push the

button to set the display panel to

Every time you push the button, the display panel reads ... repeatedly.

11
Push the button to set the display panel to . Every time you push the button, the display panel reads ... repeatedly.

12
Setting is not required if you must a value which has a default.

Push the

button to set the display panel to

Every time you push the button, the display panel reads ... repeatedly.

Step 3 : Upon completion of the selection, check you made right selections. Press the Mode Selection key, to set the display part to and check the display part. The display part shows . Press the Mode Selection key, The display part shows to set the display part to . and check the display part.

Step 4 : Pressing the ON/OFF button ( ) When pressing the operation ON/OFF key with the direction of remote controller for unit, the sound ''Ding'' or ''Diriring'' is heard and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input of option is completed. (If the diriring sound isn't heard, try again pressing the ON/OFF button.) Step 5 : Unit operation test-run First, Remove the battery from the remote controller. Second, Re-insert the battery into the remote controller. Third, Press ON/OFF key with the direction of remote controller for set.
Error Mode 1st If all lamps of indoor unit are flickering, Plug out, plug in battery again and press ON/OFF key to retry. 2nd If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for its model.

Samsung Electronics

15

Set up the Model Option

s OPTION ITEMS
REMOCON SEG1 MODEL SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12

SH09BPH

SH12BPH

16

Samsung Electronics

6. Troubleshooting
Since the inverter air conditioner is equipped with Electrical control circuits at both Indoor & outdoor unit, the trouble shooting shall be performed according to the error mode. Inside the controller of the outdoor unit (inverter), the large capacity of electrolytic condenser so that it takes the time to discharge after the power off since the electrical charge remains(the charging voltage DC 340V). Take care of the electrical shock by contact on the charging part before the discharge after the power off. (It takes approximately 2 minutes to discharge).

6-1 Basic items for trouble shooting


1. 2. Is the power source proper? The power source shall be in the range of the rated voltage 10%. If it is out of this range, it may cause the abnormal operation. Is the connection made between the indoor and outdoor unit? The connection between indoor and outdoor unit shall be performed with 4 wire. (connection cable of indoor and outdoor unit + ground wire). The phenomena as follows are not out of order.
No 1 Phenomena The operation is not done. Cause and reason Is the power off or the power unplugged? Does it stop because it is the completion time? Unplug and plug again the power source for 2 minutes. Is the filter clogged with dust or dirty? Is there any direct light on the outdoor unit or any obstacle against it? Is the selected temperature too high? Lower the selected temperature lower than the current one (during cooling). Is the selected temperature too low? Raise the desired temperature than the current one? (during heating) Is the "Fan only Mode" operation? Is the battery run out? Is the battery inserted in the wrong way(+, -)? Is the detection part of the indoor unit blocked? Does it interfered with the radio of neon sign? Is the operation selected among one of Auto / Dry / Turbo / Sleeping? The temperature setting is not required since the wind volume set automatically. Check again at the state of Cooling / Fan only / Heating. Is the operation selected among the Dry / Turbo / Sleeping / Fan only Mode. Since the temperature is automatically set, the temperature setting is not required. Check again at the cooling / heating state. The standard temperature 2C during the automatic operation. Push the Operation / Stop button. Unplug and plug the power source. It is the case that the auto restart function works. Auto restart function is the convenient function where the operation state is memorized in the Memory IC during the blackout and the operation restarts when the power comes back.

3.

The wind comes out but the heating/cooling is not performed.

The remote controller does not operate.

The wind volume is not adjusted.

The temperature is not set.

The operation lamp continues to be flickering. The immediate operation starts without control of remote controller when plugged

Samsung Electronics

17

6-2 The first determination method of troubled part


6-2-1 Error mode display of indoor unit

TEMPERATURE / ERROR CODE

ERROR CODE DISPLAY

Discription Indoor Unit Indoor unit room temperature sensor error (open / short) Indoor unit heat exchanger out temperature sensor error(open / short) Indoor unit heat exchanger in temperature sensor error(open / short) EEPROM error Option code setting error Indoor fan motor malfunction Communication error or miss-wiring error Communication error between the indoor unit and outdoor unit Compressor protection error Abnormal increase of operation current Abnormal increase of OLP temperature Abnormal increase of discharge temperature Over current of IPM circuit Abnormal increase of heatsink temperature BLCD compressor starting error Outdoor unit sensor error (open / short) deice temp-sensor outdoor temp-sensor discharge temp-sensor OLP temp-sensor Outdoor control PCB error Communication error between 2 micom on the outdoor PCB current sensor error heatsink temp-sensor error Voltage sensor error

Check point INDOOR OUTDOOR

Temp-Sensor Temp-Sensor Temp-Sensor PCB Option Code Fan and cable

PCB, Cable between Indoor and outdoor unit

Comp. Fan Fan Comp. PCB,Comp wire

Temp-Sensor Temp-Sensor Temp-Sensor Temp-Sensor

PCB PCB PCB PCB, Outlet voltage

Error display :

and 2-digit-number are displayed alternately

18

Samsung Electronics

Troubleshooting

6-2-2 Error mode display of outdoor unit board

RED GRN YEL ULN2003

LAMP of Display Monitor YELLOW X X X X X X X X X X X X X GREEN X X X X RED X Power Off / VDD NG Comp. Peak Current (O.C.) Communication NG Comp. Starting error Heatsink sensor error Normal Operation DC-Iink overvoltage error 4-Way valve error Heatsink Temp. trip Outdoor Sensor error(Open/Short) Discharge sensor temp. trip Discharge sensor error(Open/Short) OLP sensor error(Open/Short) CT sensor error X Unit Over Current protection Deice sensor error(Open/Short) OLP sensor temp. trip X X X OPTION error (EEPROM) Compressor rotation error DC fan error (SH12BWHX only) DC-Link voltage sensor error PFC OC error X NO GAS error AC Line zero-crossing error : Lamp on

Description : Lamp flickering

X : Lamp off

Samsung Electronics

19

6-3 Sequence of trouble shooting for inverter aircon

OPERATION START

The indoor unit does not work even though the power is plugged. There is no sound "DING" The lamp is not on the display.

Check the indoor unit control board. (A)

The indoor unit does not work when operated by the remocon.

Checking the Remocon.(B)

Check the control board and display board of indoor unit.(C)

The 2 digit part of indoor LED display shows Error Code and the unit stops several minutes after the indoor uint starts.

Check the error code on the LED display(A), (D)-(O)

In case of Error Code : Er/E1(D), Er/E5(D), Er/05(D), Er/06(A), E3/01(E)

Check the indoor unit

In case of Error Code : Er/09

See section 5. Setup the model option

In case of Error Code : E3/01 (F)

Check the communication line

In case of Error Code : E3/E6(H), Er/17(K), In case of Error Code : Er/31(H), Er/32(G), Er/33(G), Er/36(K), In case of Error Code : Er/37(I), Er/38(K)

Check the outdoor unit

In case of Error Code : Er/11(J), Er/12(M), Er/13(M), Er/14(L), In case of Error Code : Er/15(N), Er/18(O)

Check the outdoor unit and outdoor unit installation

20

Samsung Electronics

Troubleshooting

6-3-1 (A) Check of indoor unit control board


Unplug the power cord and plug it after 5 seconds. Press the on/off switch located indoor unit inside to operate the air conditioner. x If the air conditioner operates, check the remocon and indoor unit display board. x If the air conditioner does not operates, check according to the sequence of the followings: Check sequence of indoor unit control board x Step 1 : Check whether two wires of power cord (Sky-blue, brown) are connected correctly to the terminal block and Relay on the control board. x Step 1 : Sky -blue : connected to "N1" of Terminal block x Step 1 : Brown : connected to RY71 Tab terminal (control board outer side) x Step 2 : Check whether the wire connected to the terminal block is connected to th control board. (Control board) CN71 RY71 CN71
SKY-BLU BRN BLK

(Terminal block) (N1) 1 2

x Step 3 : Check whether the fuse (F701)(F702) on the control board is normal. (3.15[A]/250[V]:F701) (1[A]/250[V]:F702) x Step 1 : If the fuse is broken, replace it with new one. x Step 4 : Check the output voltage of SMPS on the control board. x Step 1 : Input power AC178 ~ AC 264V CN22 1-3pin : DC12V x Step 1 : - Input power AC178 ~ AC 264V CN22 2-3pin : DC5V x Step 1 : - CN22 : As socket not mounted measure at the solder points x Step 5 : Check whether the control board gets wet with dew x Step 1 : Dry the control board. x Step 6 : Check whether tiny metal objects make a short fircuit on the PCB, especially between pins of the surface mount IC. x Step 1 : remove the objects. Do not use splay solvent or some components may get damage by solvent.

6-3-2 (B)(C) Display board and remocon check of indoor unit


Check whether the connection wire of Display board is correctly connected to CN53 connector. Check the voltage of remocon battery. - the voltage of one battery shall be higher than about 1.4V, and then the remocon operates normally. Check whether the neon sign is on and the 3 wave long fluorescent lamp is on around the indoor unit. - After putting all lamps of the indoor out and then operate it by remocon. If it operates with the remocon, it is the abnormality due to the interference from the light of lamps. (Aircon unit is normal).

6-3-3 (D) Check the indoor temperature sensor and indoor heat exchanger temperature sensor.
Take out the thermistor connected to the connector (CN41,CN42) of control board of indoor unit and measure the resistance between two wires and if it is same as follows: it is normal but if not, replace it.
Ambient temperature (C) Resistance of thermistor [K] 15C 14.68 20C 12.09 25C 10 30C 8.31 35C 6.94 40C 5.83

Samsung Electronics

21

Troubleshooting

6-3-4 (E) Check of indoor unit fan motor


s s s s
1. Check whether the wires are connected surely between control board(CN72) and running capacitor(Tab). 1. Check whether the wire of fan motor is connected to the control board (CN73,CN74) of indoor unit. 1. Check whether the error mode displays after the strong rotation for approximately 15 seconds since air conditioner turned on. 1. In case the error code displays after the fan motor is rotating for 15 seconds. Defect of HALL IC of fan motor and/or control board. s 1. In case that error code displays without fan motor rotating after 15 seconds. Operate with making short circuit of AC side pins of SSR(SS71) of indoor unit control board. And then if the fan motor does not operate, it is the fan motor defect. If it rotates, it is the defect of control board(SS71,IC05,IC04).

6-3-5 (F) Check of communication line between the indoor unit and outdoor unit
s Communication error mode s 1. Check of connection s 1. Check whether the cable wire connecting the indoor unit with outdoor unit is correctly connected to the (N1), 1, 2 terminal. (If
the wire is connected reversely, the communication error occurs)

s 1. If the cable connecting the indoor unit and outdoor unit is longer than 20m, error mode may occur (shorten the cable length). s Check of indoor unit s Check whether the connection wire of the terminal block and control board of indoor unit is correct.
(Control board) CN71 RY71 CN71
SKY-BLU BRN BLK

(Terminal block) (N1) 1 2

s Check of outdoor unit s Check whether the connection wire of the terminal block and control board of outdoor unit is correct.
(Control board) TB-N TB-L CN04
SKY-BLU BRN BLK

(Terminal block) (N1) 1 2

s 2. Check of power supply to the outdoor unit s 2. After operation of aircon, select the turbo mode and approximately 3minutes later, check whether the red color lamp of control
board (to be seen if the top cover of outdoor unit) is on.

s 2. If the red lamp (LED 3) is not on, check the power part of control board of outdoor unit. s 2. Check the connection of reactor. s 2. If the red lamp (LED 3) is on and green lamp is flickering, it is normal.

6-3-6 (G) Check of discharge temperature sensor and comp top OLP temperature sensor.
Connector of outdoor unit control board (PIN#3,4 of CN51 - discharge temperature sensor), (PIN#1,2 of CN52-OLP Temperature sensor) Measure the resistance between two wires and if it is same as follows, it is normal but if not, replace.
Ambient temperature (C) Resistance of thermistor [K] 0C 553 10C 362 20C 242 30C 166 40C 165 50C 82

22

Samsung Electronics

Troubleshooting

6-3-7 (H) Check the defrost temperature sensor and outdoor temperature sensor.
Connector of outdoor unit control board (PIN#1,2 of CN51 - outdoor temperature sensor),(PIN#3,4 of CN52-deice Temperature sensor) Measure the resistance between two wires and if it is same as follows, it is normal but if not, replace it.
Ambient temperature (C) Resistance of thermistor [K] 15C 14.68 20C 12.09 25C 10 30C 8.31 35C 6.94 40C 5.83

6-3-8 (I) Check the heatsink temperature sensor of IPM


This sensor is inside of the IPM module and PIN#24,25 of IPM module are the sensor terminal. Usually PIN solder crack or short circuit with small metal object cause sensor error. Check the object to make short circuit and solder condition of these pins.
Ambient temperature (C) Resistance of thermistor [K] 15C 77.4 20C 61.4 25C 49.1 30C 39.5 35C 31.9 40C 26

6-3-9 (J) Check of operation current abnormal increase mode


The operation abnormal current mode is the protection control for the safe operation by detecting the operation current of inverter aircon by the current sensor on the control board. If the operation current abnormal increase occurs, The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50 C) Reinstall the outdoor unit so that the good ventilation can be made. If the Refrigerant is overcharged. Check the amount of Refrigerant. If the comp is locked. Replace the comp. If the comp is operating without the revolution of fan motor. Check the fan motor connector, replace the fan motor. If the protection cover is operating with bending to the outdoor. Take out the protection cover. If two outdoor units are operating face to face. (the bad ventilation is made) Reinstall the outdoor unit for the good ventilation. The air circulation is bad due to the attachment of falling leaves Take away the leaves for the good ventilation. Check and clean the dirt of current sensor block of outdoor control board. especially IC83 pin solder C437 47uF R459 33K R461 4.7K

6-3-10 (K) Check of Current sensor, Voltage sensor and Communication between 2 micom on the board.
These errors are from component trouble on the outdoor control board. Replace the outdoor control board

Samsung Electronics

23

Troubleshooting

6-3-11 (L) Check of instantaneous over-current protection of IPM circuit.


Inverter instantaneous over-current protection mode is the mode to be actuated in order to prevent the damage of elements from the peak current of IPM circuit elements. In case that the inverter circuit instantaneous over-current protection mode actuates.

s s s s s s s s s s s s s s s s s s

condition of installation
The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50 (C) ) Reinstall the outdoor unit so that the good ventilation can be made. In case that the operation is made with the cover bent of the outdoor unit. Take out the cover. If two outdoor units are operating face to face, (the bad ventilation is made) Reinstall the outdoor unit for the good ventilation. The air circulation is bad due to the attachment of falling leaves. Take away the leaves for the good ventilation. If the Refrigerant is overcharged. Check the amount of Refrigerant.

Unit defect
If the comp is locked. Replace the comp. If the comp is operating without the revolution of fan motor. Check the fan motor connector and replace the fan motor. In case the parts of the control board is damaged. Replace the outdoor control board.

6-3-12 (M) Check of the comp discharge gas temperature and OLP temperature abnormal rise.
If the comp discharge gas temperature and OLP temperature rises higher than a certain level, it protects the circuit. If the comp discharge gas temperature and OLP temperature rises abnormally,

s s s s s s s s s s s s s s s s s

Condition of installation
The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50 (C) ) Reinstall the outdoor unit so that the good ventilation can be made. In case that the operation is made with the cover bent of the outdoor unit. Take out the cover. If two outdoor units are operating face to face, (the bad ventilation is made) Reinstall the outdoor unit for the good ventilation. The air circulation is bad due to the attachment of falling leaves Take away the leaves for the good ventilation. If the refrigerant is insufficient. Fill up the amount of refrigerant.

Unit defect
If the comp is locked. Replace the comp. If the comp is operating without the revolution of fan motor Take out the protection cover. Check the fan motor connector and replace the fan motor.

24

Samsung Electronics

Troubleshooting

6-3-13 (N) Check of the heatsink temperature abnormal rise


If the air flow around the heatsink on the control box is not good, heatsink temperature will go up and the control box will have damage. So controller check the heatsink temperature and protect at the cirtain limit. Possible troubles are fan motor trouble, fan motor drive circuit trouble and air flow blocking.

s s s s s s s s s s s s s s s s s

Condition of installation
The ventilation is not good because the outdoor unit is installed wrong (the ambient temperature is higher than 50(C)). Reinstall the outdoor unit so that the ventilation can be made. In case that the operation is made with the cover bent of the outdoor unit. Take out the cover. If two outdoor unit are operatong face to face,(the bad ventilation is made) Reinstall the outdoorunit for the good ventilation. The air circulation is bad due to the attachement of falling leaves. Take away the leaves for the good ventilation. If the refrigerant is insufficient. Fill up the amount of refrigerant.

Unit defect
If the fan is locked with some object. Remove the object. If the comp is operationg without the revolution of fan motor. Take out the protection cover Check the fan motor connector(CN54), running capacitor, relay(RY503) and replace the fan motor.

6-3-14 (O) Check BLDC compressor starting error


If the compressor have some trouble inside like locking or gas pressure of suction and discharge pipe is not balanced, Inverter system will give up compressor rotation control to protect itself from overcurrent. In case of compressor rotation starting trouble without overcurrent condition, controller detect the compressor rotation error and stop. Compressor wire connection is not good. Check Compressor TAB terminal connection of the wire and connector to control box. Gas pressure balance is not good at stop condition. Check service valve open. Check EEV motor attachement and connector. Compressor is locked or have some mechanical damage. Replace the compressor.

Samsung Electronics

25

Troubleshooting

6-3-15 (P) Check no gas error


Charge standard amount of refrigerant.

6-3-16 (Q) Check of 4-Way valve


Check whether the wires of 4-Way valve and control board of outdoor units correct. If it is normal, replace 4-Way valve.

6-3-17 (R) Check of outdoor unit fan motor (SH12BPHX only)


Check whether the wire of fan motor is connected to the control board (CN01) of outdoor unit. Check the voltage on the control board of outdoor unit and if it is same as follows, replace fan motor. Input power AC178V~AC264V. CN01 1-3pin : DC250V10% ~ DC370V10% CN01 4-3pin : DC15V

26

Samsung Electronics

6-4 Fault Diagnosis of Major Parts


Part Indoor "Temp.Sensor" Indoor "Heat ex. Sensor" Outdoor "Temp.Sensor" Outdoor "Deice Temp. Sensor" Measure resistance with a tester. Normal
Ambient temperature Resistance of thermistor[K] 15C 14.68 20C 12.09 25C 10 30C 8.31 35C 6.94 40C 5.83

Diagnosis

Abnormal Outdoor "Discharge Temp.Sensor" Outdoor "OLP Temp.Sensor" Normal

, O open or short
Ambient temperature Resistance of thermistor[K] 0C 553 10C 362 20C 242 30C 166 40C 165 50C 82

Abnormal Indoor Fan Motor

, O open or short

Measure the voltage between terminals (CN72) with a tester Normal At ambient temperature (10C ~ 30C)
between Red, Blue Red, Yellow Voltage[V] 41010% 32510% Main Sub

Abnormal Measure the voltage between ground and signal wire of the fan motor Normal
between Gray, Orange Yellow, Orange Voltage 0.5V~4.5V 5V

Abnormal Outdoor Fan Motor Normal

Abnormal if voltage does not change from 0V to 5V. At ambient temperature (10C ~ 30C)
between Black, Red Black, Yellow Resistance[] 27510% 35010% Main Sub

Abnormal Stepping Motor (UP/DOWN swing motor)

, O open or short

Measure resistance between red wire and each terminal. Normal Abnormal Approx. 290 at ambient temperature (20C ~30C) , O open or short

Stepping Motor (FRONT GRILLE motor)

Measure resistance between red wire and each terminal. Normal Abnormal Approx. 110 at ambient temperature (20C ~30C) , O open or short

Samsung Electronics

27

DB98_17175A_1

2/6/04 4:14 PM

Page 28

7. Exploded Views and Parts List


7-1 Indoor Unit
13

7
7-1

15

7-5

7-6 16-4

16

7-3 7-2 7-4 9 16-3 16-1

11 3 10

16-2 16-5

1-2

12 14

1-1-2 1-1-3 1-3 1-1-4 1-1-5 1-1-1 1-1

1-1-6 1-1-7 1-4

You can search for the updated part code number through the ITSELF.
URL : http://itself.sec.samsung.co.kr

28

Samsung Electronics

Exploded Views and Parts List

Parts List
No.
1 1-1 1-1-1 1-1-2 1-1-3 1-1-4 1-1-5 1-1-6 1-1-7 1-2 1-3 1-4 2 3 4 5 6 7 7-1 7-2 7-3 7-4 7-5 7-6 8 9 10 11 12 13 14 15 16 16-1 16-2 16-3 16-4 16-5

Code No.
DB92-00488C DB92-00392F DB92-00346A DB31-00166A DB39-00794A DB61-01114A DB61-01115A DB61-01116A DB66-00364A DB64-00494B DB63-00585C DB63-00586C DB92-00491B DB96-04189A DB95-00367B DB63-00581A DB93-02531N DB94-00304H DB61-01335A DB63-00580A DB91-00264A DB39-01451C DB73-00128A DB94-40007A DB94-00020E 6009-001001 DB31-00152B DB61-01099A DB67-60030A DB70-00276A DB93-02583B DB90-00992A DB94-00305H DB94-00062E DB61-01103A DB61-01104A DB63-00587A DB95-20138A

Description
ASS'Y PANEL FRONT-TOTAL ASS'Y PANEL FRONT-SUB P ASS'Y PANEL FRONT MOTOR STEP CONNECTOR WIRE-STEP MOTOR HOLDER-MOTOR DC HINGE-GRILLE GUIDE-LINK LINK-MOTOR GRILLE-UP FILTER-PRE LF FILTER-PRE RH ASS'Y GRILLE-LOW SUB ASS'Y EVAP-TOTAL ASS'Y-FILTER BIO COVER TERMINAL ASS'Y REMOCON ASS'Y BACK BODY-SUB BACK-BODY COVER-IONIZER ASS'Y ELECTRIC-IONS ASS'Y CONNECTOR WIRE-ION RUBBER-BEARING ASS'Y BEARING-MOTOR ASS'Y-CROSS FAN BOLT SPECIAL MOTOR FAN HOLDER-MOTOR SPRING-SENSOR PLATE-HANGER ASS'Y CONTROL IN ASS'Y HOLDER-PIPE ASS'Y TRAY DRAIN ASS'Y DRAIN-HOSE BLADE-H BLADE-V TRAY DRAIN ASS'Y MOTOR-STEPPING

Specification
ASS'Y ASS'Y ASS'Y HIPS HIPS HIPS ABS ABS PP PP ASS'Y ASS'Y ASS'Y HIPS ASS'Y ASS'Y HIPS HIPS ASS'Y ASS'Y ASS'Y PP STS301 SGCC-M ASS'Y ASS'Y ASS'Y ASS'Y HIPS PP HIPS ASS'Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1

Q'TY SH09BPH SH12BPH


1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1

Remark

Samsung Electronics

29

DB98_19047A(1)_2

4/21/04 2:27 PM

Page 32

7-2 Outdoor Unit

22

17 16

23 24

10

8 25

3 11 26 13 12 6

3-2

7 20 21

3-1

18

19

4 14 15

30

Samsung Electronics

DB98_19047A(1)_2

4/21/04 2:27 PM

Page 33

Exploded Views and Parts List

Parts List
No.
1 2 3 3-1 3-2 4 5 6 7 8 9 10 11

Code No.
DB90-01581A DB63-00847A DB90-01332A DB64-01094A DB64-00992A DB90-01546A DB63-00843A DB90-01330F DB99-00401B DB94-00584B DB61-01644A DB97-02225A DB31-00220A DB31-00238A

Description
ASS'Y-CABI FRONT GUARD FAN ASS'Y-CABI SIDE LF CABINET-SIDE LF COATING HANDLE-LF ASS'Y-CABI SIDE RH COVER-VALVE ASS'Y BASE-OUTDOOR ASS'Y VALVE-BRACKET ASS'Y PARTITION BRACKET MOTOR ASS'Y SUPPORT-PLATE B/M MOTOR FAN MOTOR FAN FAN-PROPELLER NUT-FLANGE GROMMET ISOLATOR NUT-WASHER ASS'Y COND ASS'Y CONTROL OUT ASS'Y CONTROL OUT FELT COMP SIDE COMPRESSOR ASS'Y VALVE 4WAY ASS'Y VALVE EEV BAR-STEEL ASS'Y THERMISTOR OUT ASS'Y THERMISTOR OLP/SUC SOLENOID-REACTOR CORE-FERRITE ASS'Y NR ASS'Y PP ASS'Y

Specification

Q'TY SH09BPHX
1 1 1 1 1 1 1 1 1 1 1 1

SH12BPHX
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 1

SC-90073T PP ASS'Y PP ASS'Y ASS'Y ASS'Y SGCC-M

YDK-020S62213-03 SIC-52FV-D828-1

1 1 1 3 3 1 1 1 1 1 1 1 1 1 1 0

12 13 14 15 16 17

DB67-00397A DB60-30004A DB63-00763A DB60-30028A DB96-03602A DB93-02740C DB93-02740D

SH12BPHX SH09BPHX FELT G4C090LU1ER ASS'Y ASS'Y ASS'Y ASS'Y ASS'Y 12A, 21mH ASS'Y

18 19 20 21 22 23 24 25 26

DB63-01043A G4C090LU1ER DB99-00481B DB97-02490B DB71-00090E DB32-00083C DB32-00121A DB33-00021A 3301-001738

Samsung Electronics

31

7-3 Ass'y Control In (Indoor Unit)


s SH09BPH / SH12BPH : DB93-02583A

32

Samsung Electronics

Exploded Views and Parts List

Parts List
No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Code No.
DB61-01631A DB93-02584B DB93-01368G DB93-01369A DB65-00149A DB70-00289A DB61-00171A 6001-000929 6001-000725 DB93-01380B DB39-00793A DB62-01368X DB39-00780B DB39-00820A DB61-01110A DB64-00763A 2301-001339 DB72-00126N DB32-00084B DB32-00054B DB39-00183A DB93-01549C 6001-001054

Description
CASE-CONTROL ASS'Y MAIN PCB ASS'Y S/W & DISPLAY PCB ASS'Y-MODULE PCB ASS'Y TERMINAL BLOCK PLATE TERMINAL LOW HOLDER WIRE CLAMP SCREW-MACHINE SCREW-MACHINE C/W MODULE C/W STEP MOTOR UP/DOWN SEAL SCREW-MACHINE C/W STEPPING MOTOR C/W ION-PCB HOLDER-DISPLAY HALF MIRROR FAN CAPACITOR SEAL THERMISTOR THERMISTOR C/W FAN_CAP POWER CORD SCREW-MACHINE ABS ASS'Y ASS'Y ASS'Y ASS'Y

Specification

Q'TY
1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Remark

SGCC-M,T1.2 HIPS PH M3xL22 TH M4xL16 ASS'Y ASS'Y 61x40x3,30FOAM-PE,GRAY PH M4x10 ASS'Y(AUTO GRILLE) ASS'Y ABS 95,T1.5 1.2 F/450V T3, FOAM-PE,GRAY OUT,6,220 IN,5,200 UL1015 AWG #22 15A TH M4xL10

SNA SNA

SNA SNA

Samsung Electronics

33

7-4 Ass'y Control Out


s SH09BPHX : DB93-02740D s SH12BPHX : DB93-02740C

34

Samsung Electronics

Exploded Views and Parts List

Parts List
Q'TY No.
1 2 3

Code No.
DB93-01627A DB62-02749A DB93-02741C DB93-02741D

Description
CASE CONTROL BASE HEAT SINK MAIN ASS'Y PCB OUT ASS'Y PCB OUT SCREW-MACHINE SCREW-MACHINE SCREW-TAPPING CASE CONTROL COVER CONNECTOR WIRE COMP CONNECTOR WIRE REACTOR CONNECTOR WIRE FAN ASS'Y L/W POWER CONNECTOR WIRE 4 WAY V/V INSULATOR-MICA ASS'Y TERMINAL BLOCK 3P HOLDER WIRE PLATE-CASE CONTROL SCREW-TAPPING SCREW-TAPPING SCREW-TAPPING FOAMLEX RUN CAPACITOR SCREW-TAPPING SEAL CASE CONTROL BASE

Specification
ABS 5V ASS'Y ASS'Y M4xL16 WSP PH+ M3xL16 WSP PH+ PH,+,2S,M3,L8 RESIN-ABS UL1015 AWG#16 UL1015 AWG#16 UL1007 AWG#20 UL1015 AWG#16 UL1015 AWG#18 3P PP SGCC-MTO.6 PH,+,2,M3,L20 TH,+,1,M4,L10 PH,+,2S,M4,L10 60x180xT2.0 1.7F/450V M3x14 WSP PH+ 70x15xT10

SH09BPHX
1 1 1 5 2 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1

SH12BPHX
1 1 1 5 2 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1

4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

6006-001051 6006-000160 6002-000630 DB61-01628A DB39-00608E DB39-00607B DB39-01003A DB93-02775A DB39-00649C DB65-00086A DB61-00250A DB70-00465A 6003-000325 6005-000643 6002-000171 DB93-00936A DB62-02541L

Samsung Electronics

35

8. PCB Diagram
8-1 ASS'Y PCB Indoor Unit : DB93-02584A
s TOP

36

Samsung Electronics

PCB Diagram

s BOTTOM

Samsung Electronics

37

PCB Diagram

Parts List
Location No.
D101 D701,D702,D703 BD71 ZD11 ZD71 ZD12 CD11 Q201,Q401,Q602 Q603 Q301,Q302,Q601 IC05,IC06,IC07 PC02 PC01,PC31,PC32 IC08 IC51 IC03 IC01 VA71,VA72,VA73 R703,R704 R701,R702 R601,R602 R504,R505,R506 R302,R604,R605 R201,R207,R208,R301 R401,R403,R607,R903 R603,R901 R206,R902 R510,R511 R606 R706 R202,R203,R304,R205 R707 R102,R103,R104 R106,R407 R101 R105 R402,R501,R502,R503 R303 C104 C103,C107,C110,C112,C201 C202,C500,C501,C502,C503 C901 R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP C-CERAMIC,DISC C-CER,CHIP 4.7Kohm,5%,1/10W,TP,1068 10Kohm,5%,1/10W,TP,1068 47Kohm,5%,1/10W,TP,1068 560ohm,5%,1/10W,TP,1068 100Kohm,5%,1/8W,TP,2012 100Kohm,5%,1/4W,TP,3216 1Kohm,5%,1/8W,TP,2012 220Kohm,5%,1/4W,TP,3216 220ohm,5%,1/8W,TP,2012 4.7Kohm,5%,1/8W,TP,2012 470ohm,5%,1/8W,TP,2012 6.8Kohm,1%,1/10W,TP,1068 8.2Kohm,1%,1/10W,TP,1068 2.2NF,20%,400V,Y5U,BK,12.5x6mm,10 100nF,+80-20%,50V,Y5V,TP,2012 2 2 2 1 1 4 1 3 2 1 1 4 1 1 11

Description
DIODE-RECTIFIER DIODE-RECTIFIER DIODE-BRIDGE DIODE-ZENER DIODE-ZENER DIODE-ZENER DIODE-TVS TR-SMALL SIGNAL TR-SMALL SIGNAL TR-DIGTAL TR-ARRAY PHOTO-COUPLER PHOTO-COUPLER IC-SOURCE DRIVER IC-EEPROM IC-VOLTAGE COMP. IC-PWM CONTROLLER VARISTOR R-METAL OXIDE(S) R-METAL OXIDE(S) R-CHIP R-CHIP R-CHIP R-CHIP

Specification
UG2D,200V,2A,DO-204AC,TP MRA4005,600V,1A,SMA,TP DF06S,600V,1A,SMD-4,TP BZX84C3V6,3.6,350mW,SOT-23,TP 1N4749A,24V,5%,1W,DO-41,TP BZX84-C11,10.4-11.6V,350MW,SOT-23,TP ST02D-200,185/200/215V,200W,DO-214 2SC2412K,NPN,200mW,SOT-23,TP,1 MMST2907A,PNP,200mW,SOT-23,TP,100DTC114EKA,NPN,200mW,10K/A0K,SOT-23,TP 2003,NPN,7,1W,SOP-16,ST,1000 TR,50-150%,200mW,DIP-4,ST TR-100-300,200mW,SOP,TP TD62783AFW,SOL,18P,-,8,-500MA,TP 93LC56,128x16Bit,SOP,8P,150MIL,-,2.5V,7533,TO-92,3P,-,SINGLE,-,-,PLASTIC 255,DIP,8P,300MIL,PLASTIC,-0.3/7 INP14D561K 4.7Kohm,5%,2W,AA,TP,4x12mm 47Kohm,5%,3W,AA,TP,6x16mm 10Kohm,1%,1/10W,TP,1068 330ohm,5%,1/10W,TP,1068 470ohm,5%,1/10W,TP,1068 1Kohm,5%,1/10W,TP,1068

Q'TY
1 3 1 1 1 1 1 3 1 3 3 1 3 1 1 1 1 3 2 2 2 3 1 8

Remark

38

Samsung Electronics

PCB Diagram

Parts List (cont.)


Location No.
C301,C510,C706,C903 C203,C204,C302,C303 C401,C705 C702 C703,C704 XC71,XC72 C111 C106 C701 C601 C101,C102 L101 X301 BZ61 RY71 SS71 F701 F702 CN72 CN73 CN74 CN62 CN71 CN42 CN51 CN53 CN61 CN41 CN81 IC02 IC04 ST11 DSA JE PCB FT72 C001 LS403110 SC102M Y-CAP 7.5mm IC MICOM TRANS SWITCHING POSISTOR LEAD-WIRE C-FILM,LEAD-PEF C-FILM,LEAD-PEF C-FILM,MPPF C-AL C-AL C-AL C-AL C-AL INDUCTOR-RADIAL RESONATOR-CERAMIC BUZZER-PIEZO RELAY-POWER SSR FUSE-CARTRIDGE FUSE-RADIAL LEAD CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER 10nF,10%,630V,TP,16x11x7.5mm,5 4.7nF,10%,100V,TP,10x8.5x5.0mm 100nF,10%,275V,BK,18x6x12,15 470uF,20%,16V,GP,TP,8x11.5,5 1000uF,20%,25V,GP,TP,13x20,5 470uF,20%,50V,GP,TP,13x20,5 47uF,20%,50V,GP,TP,6.3x11,5 6.8uF,20%,450V,GP,TP,10x16mm,5 5000uH,10%,8.0x11.0mm 10MHz,0.5%,TP,10.0x5.0x10.0mm 70dB,3V,-,2KHz,BK 12VDC,0,9W,20000MA,SPST,20MS,10MS 12Vdc,-,2A,1mS,1mS 250V,3.15A,FAST-ACTING,CERAMIC,5.2x20mm 250V,1A,TIME-LAG,-,8.5x8mm 1WALL,2P,1R,7.92mm,STRAIGHT,SN,WH 1WALL,3P,1R,7.92mm,STRAIGHT,SN,WH BOX,3P,1R,2.5mm,STRAIGHT,SN,BLU BOX,5P,1R,2.5mm,STRAIGHT,SN 1WALL,2P,1R,7.92mm,STRAIGHT,SN,BLU BOX,2P,1R,2mm,STRAIGHT,SN,WHT BOX,14P,1R,2mm,STRAIGHT,SN BOX,3P,1R,2mm,STRAIGHT,SN PH-5A,BOX,5P,2mm,WHT BOX,4P,1R,2mm,STRAIGHT,SN,WHT PH-3A,BOX,3P,1R,2mm,BLU KA78L05AZTA(0.1A,Positive,Vol,Reg) MB89538APF-101,MB89538APF-101,64P,+5V,10M DC12V,-,-,-,-,-,-,12V,0.01A,-,E119 DSA-332MA,2pF MAX,100Mohm,ASM-3 UL1015 AWG#20 GRN/YEL 1 2 2 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Description
C-CER,CHIP C-CER,CHIP

Specification
1nF,10%,50V,X7R,TP,2012,10nF,+80-20%,50V,Y5V,TP,2012

Q'TY
4 6

Remark

Samsung Electronics

39

8-2 Ass'y PCB Outdoor Unit : DB93-02741D(9K) / DB93-02741C(12K)


s TOP

40

Samsung Electronics

PCB Diagram

Parts List
Location No.
D102 BD01 C011,C010 C003,C004 C01 C101,C102,C103 C104,C105,C304 C123 C201,C437,C117,C508 C301 C303,C308 C402,C404,C406,C407 C409,C410,C411 C416,C905 C418 C464,C466,C108,C109,C110 C509 C520,C516,C506,C507,C513,C514,C202 C518,C551,C413,C414,C415,C412 C521,C305,C306,C302,C307 C653 C702 C902 CN01 CN04 CN52,CN51 CN53 CN701 D101 D201 D401,D402,D403 DSA FT01 FT00 FUSE IC01 IC11 IC17 IC18 IC19 IC21,IC32 IC701 IC73 C-CER,CHIP C-CERAMIC C-AL C-AL CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER CONNECTOR-HEADER DUAL-DIODE DIODE-RECTIFIER DIODE-RECTIFIER SURGE-ABSORBER SS2915044B SS2915025B FUSE IC-MICOM IC-PWM CONTROLLER IC-POSI.FIXED REG IC-POSI.FIXED REG IC-POSI.FIXED REG PHOTO-COUPLER IC-EEPROM IC-POSI.ADJUST REG 10nF,50V,1608 10nF,25V 100uF,16V 10uF,50V YAW396-07V,WHT YAW396-03AV,BLU SMAW250-04,WHT SMAW250-06,WHT SMW200-04,NTR FEP30JP US1G,400V 1N4937,600V,1A DSA332M SS2915044B SS2915025B 65TS-150-H,250V,20A ML66Q517 TOP222P,8P/DIP KA7805A,TO-220 KA7815 KA7812A,TO-220 TLP181-GRH,150-300% 93LC56,128x16Bit TL431,8P/SMD 5 1 1 1 1 1 2 1 1 1 1 3 1 1 1 1 1 1 1 1 1 2 1 1 DIODE DIODE-BRIDGE C-CERAMIC C-CERAMIC C-CERAMIC C-AL C-CERAMIC C-AL C-AL C-FILM C-CER,CHIP C-CER,CHIP C-AL C-AL C-FILM C-AL C-CER,CHIP C-CER,CHIP

Description
1N4937,600V/1A GSIB2560 103,2KV 0.33uF,275V 684,275V 560uF,400V 222,2KV 10uF,450V 47uF,35V 10nF,100V 1nF,50V,1608 470pF,1608 47uF,50V 220uF,50V 100nF,630V 220uF,25V 47nF,50V,2012 100nF,25V,1608

Specification

Q'TY
1 1 2 2 1 3 3 1 4 1 2 4 3 2 1 5 1 13

Samsung Electronics

41

PCB Diagram

Parts List (cont.)


Location No.
IPM LED1 LED2 LED3 PT02 PTC1 Q202,Q302,Q301,Q905,Q907,Q902 Q803 Q901,Q903,Q904,Q906 R001 R101 R102 R115 R201 R202 R204,R515 R301,R307 R303,R304 R305,R404,R403,R402,R401,R406,R415 R306 R418 R425,R423,R421 R459 R460 R507,R508 R510,R511,R509 R512 R513,R514,R529,R528,R527,R526,R530 R531,R525,R524,R522,R521,R533,R534 R535 R536 R537,R538 R801 R812,R506,R517,R505,R553 RY01 RY502,RY501 VA07,VA08,VA09,VA03,VA04 XTAL01 ZD21 ZD23,ZD22 ZD31 R-CHIP R-CHIP R-CEMENT R-CHIP RELAY-POWER RELAY-MINIATURE VARISTOR RESONATOR-CERAMIC DIODE-ZENER DIODE-ZENER DIODE-ZENER 1M-J,1/10W,1608 10K-J,1/10W,1608 0.045-J,3W 330-J,1/12W,1608 UKH-12S,12Vdc/20A FTR-F3AA012E,12Vdc/5A INR14D561K-RS,560V,2500A 6.25MHz,* 1N4749A,24V/1W MMBZ5232B,* 1N4751A,30V/1W 1 2 1 5 1 2 5 1 1 2 1 IPM LED LED LED PULSE TRANS PTC TR-DIGITAL IGBT-SGL TR-DIGITAL R-CEMENT R-METAL OXIDE(S) R-CHIP R-CHIP R-METAL OXIDE R-METAL OXIDE R-CHIP R-METAL OXIDE(S) R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP

Description
FSAM15SM60A,* 3mm/2.54,RED 3mm/2.54,GRN 3mm/2.54,YEL PT_30AM,* PTC,27R KRC102S,*

Specification

Q'TY
1 1 1 1 1 1 6 1 4 1 1 1 1 1 1 2 2 2 7 1 1 3 1 1 2 3 1 15

IRG4BC30F,* KRA102S,SOT-23 200-J,5W 47K-J,3W 6.8-F,1/10W,2012 14.3K-F,1/4W,3216 47K-J,2W 100K-J,2W 20K-J,1/8W,1608 4.7K-J,2W 470-J,1/10W,1608 4.7K-J,1/12W,1608 560-J,1/12W,1608 0.02R-J,7W 100-J,1/8W,1608 47K-J,1/8W,2012 20K-J,1/8W,2012 1K-F,1/12W,1608 100K-J,1/12W,1608 5.6K-J,1/12W,1608 10K-F,1/12W,1608

42

Samsung Electronics

PCB Diagram

s BOTTOM

Samsung Electronics

43

PCB Diagram

Parts List
Location No.
C111,C801 C203,C421 C401,C403,C405,C517 C106,C118,C121,C122,C124,C408 C417,C423,C519,C802,C803 C451 C452 C453,C454,C462 C806 C900 C204,C455,C501,C502,C503,C804 C805,C807,C903,C904,C906,C907 D103,D104,D106 D202,D451 D301 IC02 IC15 IC31 IC451 IC55,IC56 IC74 IC83 Q201,Q802 Q801,Q804 R002,R003 R105 R110,R111,R451 R112,R113,R114 R203,R405,R461,R804 R407,R408,R409 R104,R106,R413 R414,R523,R532,R808,R810 R416 R419,R420,R422,R424 R426,R427,R428 R429 R430 R452 DIODE-RECTIFIER DUAL-DIODE DIODE S80142 PHOTO-COUPLER PHOTO-COUPLER IC-OP AMP TR-ARRAY IC-LOGIC LM324 TR-DIGITAL TR-SMALL SIGNAL R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP ES1D,200V/1A DCB010,* ES1D,200V S80142ANMC-JC3T2,* TLP181,* TLP181-GRH,150-300% LA6393M,* ULN2003AFW,1W 74HCT00D,SOP-14 LM324,* KRC102S,* BC847B,* 470K-F,1/2W,5025 6.8K-F,1/8W,2012 180K-F,6432/1W 470K-F,1/4W 4.7K-J,1/8W,2012 33-J,1/10W,2012 3.3K-J,1/8W,2012 10K-F,1/10W,2012 390-J,1/10W,2012 100-J,1/8W,2012 300K-F,1W,6432 1.6K-F,1/8W,2012 51-F,1/8W,2012 150K-F,1W,6432 3 2 1 1 1 1 1 2 1 1 2 2 2 1 3 3 4 3 3 5 1 4 3 1 1 1 C-CERAMIC C-CERAMIC C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP 33pF,25V 4.7nF,25V 2.2nF,2012 470pF,50V,2012 1uF,3225 10nF,50V,2012 1 1 3 1 1 12

Description
C-CER,CHIP C-CER,CHIP C-CER,CHIP C-CER,CHIP 1uF,2012 1nF,50V,2012 1.2nF,2012 100nF,50V,2012

Specification

Q'TY
2 2 4 11

44

Samsung Electronics

PCB Diagram

Parts List (cont.)


Location No.
R453 R501,R504 R539,R540,R541 R502,R552 R554 R802 R803 R805 R302,R807 R103,R811,R813 R814 R806,R809,R901,R902, R903,R904,R905,R908 R906 R907 R-CHIP R-CHIP 6.8K-J,1/8W,2012 560-J,1/8W,2012 1 1 R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP R-CHIP

Description
2.7K-F,1/8W,2012 5.1K-F,1/8W,2012 2.2K-J,1/8W,2012 24K-F,1/8W,2012 470-J,1/8W,2012 220-J,1/8W,2012 2.2K-F,6432/1W 3.3K-F,1/8W,2012 1K-J,1/8W,2012 330-J,1/8W,2012 5.1K-J,1/8W,2012 10K-J,1/8W,2012

Specification

Q'TY
1 2 3 2 1 1 1 1 2 3 1 8

Samsung Electronics

45

8-3 ASS'Y DISPLAY PCB(9K / 12K) : DB93-01368G

Parts List
No
1 2 3 4 5 6

Description
ASS'Y LED MODULE PCB-DISPLAY TACT SWITCH RESISTOR RESISTOR CONNECTOR WIRE FR-1 T1.6

Specification

Q'TY
1 1 1 2 3 1

Remark
SNA SNA SNA SNA SNA SNA

KPT-1105A TSTA-2 200ohm, 2W 100ohm, 2W 14P

46

Samsung Electronics

8-4 ASS'Y MODULE PCB(9K / 12K) : DB93-01369A

Parts List
No
1 2 3 4 5 6 PCB-DISPLAY CONNECTOR C-CERAMIC DIODE SWITCHING C-CERAMIC MODULE REMOCON

Description
FR-1 T1.6

Specification

Q'TY
1 1 1 1 1 1

Remark
SNA SNA SNA SNA SNA SNA

SMAW200-03P(WHT) CA OA 50V 102K 1N4148 CA OA 50V 104Z FRP4021-H7(7mm)

Samsung Electronics

47

DB98_17175A_1

2/6/04 4:14 PM

Page 49

9. Wiring Diagram
9-1 Indoor Unit(9K / 12K)

This Document can not be used without Samsung's authorization.

48

Samsung Electronics

DB98_19047A(1)_2

4/21/04 2:27 PM

Page 50

9-2 Outdoor Unit(9K / 12K)

Code No : DB98-17635A

This Document can not be used without Samsung's authorization.

Samsung Electronics

49

MEMO

50

Samsung Electronics

ELECTRONICS

This Service Manual is a property of Samsung Electronics Co., Ltd. Any unauthorized use of Manual can be punished under applicable International and/or domestic law.

Samsung Electronics Co., Ltd. Printed in China.