OPW AST Catalog - SFLB
OPW AST Catalog - SFLB
OPW AST Catalog - SFLB
2011
Overfill Prevention
Spill Containment
Tank Valves
Tank Venting
Dispensing Products
Protective Curbing
www.opwglobal.com
U N I T E D S TAT E S | BRAZIL | EUROPE | CHINA | AND EVERYWHERE IN BETWEEN
OPW is Leading the Way in Above Ground Storage Tank Equipment Solutions
Offering the Only AST Products Certified* to Meet the Worlds Most Rigid Vapor Recovery Air Quality Standards
OPW AST products are designed to meet the highest operational performance and air quality standards. In fact, our AST equipment is the only solution in the industry actually certified by the California Air Resources Board (CARB) to meet stringent air quality standards. Whether for vapor recovery applications or any other AST application, OPW AST equipment is the best overall solution for longevity, reliability and for maintaining or promoting the well being of the public, employees and consumers through clean air and water. At OPW, we are committed to the long-term sustainability of our world. Every AST product we build is about enabling operators to provide a safer, cleaner, greener environment for themselves, their families and their customers. Benefits of an OPW AST Solution include: The only AST system and components certified by the California Air Resources Board, proving that it can help operators do their most to promote a healthier, sustainable environment for themselves, their families, employees, consumers, their communities and the general public Expertly designed products to protect the air we breathe and the water we drink Lowest Life Cycle Cost - OPW quality products help to reduce installation and maintenance costs and potential compliance violations and fines by providing reliable long product life and consistently high performance Compliance the only system to meet CARB AST EVR Stage 1 Compliance Regulations if your state adopts the new AST EVR rules, with an OPW AST solution, youre covered. OPW AST products are used in a wide range of applications, including: Retail outlets using ASTs Fleet / Commercial fueling operations Municipalities Aviation fueling locations Agriculture, Construction, Maintenance and Emergency Response operations Any application where the AST operators or local jurisdictions are concerned about maintaining or promoting the well-being of the public, employees and consumers In a class by themselves, OPW AST products ensure that you are in compliance while helping to protect the people and the environment while delivering unmatched durability and reliability.
* As of the printing of this catalog, OPW is the only manufacturer offering Above Ground Storage Tank products certified by the California Air Resources Board (CARB) to meet stringent air quality standards.
Above Ground Tank Diagrams - Non-EVR Direct Fill AST Application............................................................................................ 3 - 4 - Non-EVR Remote Fill / Remote Dispensing AST Application..................................... 5 - 6 - Non-EVR Remote Fill / Remote Dispensing AST Fleet Application........................ 7 - 8 - Non-EVR Remote Fill Diesel/Fuel Oil/Generator Application...................................9 - 10 - Phase 1 CARB Certified AST EVR Direct Fill AST Application.................................11 - 12 - Phase 1 CARB Certified AST EVR Remote Fill / Remote Dispensing AST Application.....................................................................................................................................13 - 14 Emergency Venting Size Selection Guide...................................................................................15 - 16 Spill Containment........................................................................................................................................17 - 18 Overfill Prevention ......................................................................................................................................19 - 20 Fuel Delivery Coupler/Accessories...................................................................................................21 - 22 Stage 1 Vapor Recovery Adaptors, Caps and Bushings.....................................................23 - 25 Tank Venting.....................................................................................................................................................26 - 31 Electronic Fuel Management Systems....................................................................................................32 Mechanical Tank Gauges...................................................................................................................................33 Tank Alarms................................................................................................................................................................34 OPW 62M Monitor Probe Cap & Adaptor..............................................................................................35 Face Seal Adaptor and Dedicated Gauging Port.............................................................................36 Anti-Siphon Valves.................................................................................................................................................37 Solenoid Valves........................................................................................................................................................38 Two-Way Ball Valve................................................................................................................................................39 Emergency Shut-Off Valves.............................................................................................................................40 Swing Check Valves...............................................................................................................................................41 Dispensing Products............................................................................................................................................42 Hose Retractors............................................................................................................................................... 43- 45 Dispenser Pedestals..............................................................................................................................................46 Piping & Containment.........................................................................................................................................47 Island Forms & Protective Curbing.............................................................................................................48 Fuel Compatibility Matrix.................................................................................................................................49 OPW Standard Product Warranties............................................................................................................50
2
2
A
1
B D
20
Suction Pump
21
B A
3
C
9
D
16
1 2
PRODUCT KEY
200TG-ENG Series Tank Gauge (optional / see Note below) 61T Series Drop Tube
33 33 26 26 25 24 25 23 21 21-22
10 11 12
17 18
3 4 5 6 7 8 9 10
301 Series Emergency Vent - NPT Mount (See Vent Size Configuration Guide on page 15) 301 Series Emergency Vent - Flanged Mount (See Vent Size Configuration Guide on page 15) 1711T-7085-EVR Cap 1611AV Series Vapor Recovery Adaptor 1711LPC-0300 Low Profile Cap 61VSA Series Vapor Recovery Adaptor 1290 Automatic Shut-Off Nozzle 633BD-1261 Kamlok Coupler A) 634B-0150 Dust Cap or 634BK-0090 Lockable Dust Cap fits 633AST-2061 Spout Adaptor B) 634B-0170 Dust Cap or 634BK-0100 Lockable Dust Cap fits 633AST-3061 Spout Adaptor 633AST-2061 (2" x 2") or 633AST-3061 (3" x 3") Tank Inlet Spout Adaptor 331 or 332 Series Spill Container 61fSTOP-XXXX Series Overfill Prevention Valve 61FT Series Drop Tube 634B-0150 or 634BK-0090 Cap 204247 Dedicated Gauging Port 633AST-0200 Adaptor 53-00XX Series Double Tapped Bushing 62M Series Monitoring Probe Cap & Adaptor FSA-400 Face Seal Adaptor
14
4" Nipple (not supplied) 2" Nipple (supplied) 2" Nipple (not supplied)
19
13
with 1DK-2100EVR Drain Valve 2" Pipe (not supplied)
11
B
5 7
TOP OF AST (not supplied) TOP OF AST (not supplied)
12 13 14 15 16 17 18 19 20
21 17 19-20 20 21-22 36 21 35 35 36
14 6
OR
15
TOP OF AST (not supplied)
21
6"
Direct fill drop tubes shall be cut at 45 angle, with top of cut no greater than 6" from the bottom of the tank (Or if outside the State of California, per local requirements)
NOTE: The OPW 200TG and 144TA/444TA are not required for EVR compliance, but if a tank gauge or tank alarm is used on your tank then these two OPW products are the only CARB AST EVR certified tank gauge and alarm.
A
2
3 3
Vapor Return
Fill Pipe
27
28 5
18
24 24
1 1
A
7 8 9
B
14
25 or 26
KEY
PRODUCT KEY
OPW PART / DESCRIPTION 178S Series Emergency Valve 821 Series Solenoid Valve 21BV Series Ball Valve 199ASV Series Anti-Siphon Valve 82RV Series Pressure Relief Valve 53-00XX Series Double Tapped Bushing 634B-0150 or 634BK-0090 Cap 204247 Dedicated Gauging Port 633AST-0200 Adaptor 301 Series Emergency Vent - Threaded Mount (See Vent Size Configuration Guide on page 15) 301 Series Emergency Vent - Flanged Mount (See Vent Size Configuration Guide on page 15) 61fSTOP-XXXX Series Overfill Prevention Valve 61FT Series Drop Tube 200TG-ENG Series Tank Gauge (optional / see Note below) 61T Series Drop Tube TGTA-0400 4" Gauge/Alarm Combo Fitting (optional) 44TA-LLFS Liquid Level Float Switch 175 Series Swing Check Valve 6211R Series Remote Spill Container 1611AN-0200 or 1612AN-0200 - 2" Remote Fill or 1611AN-0300 or 1612AN-0300 - 3" Remote Fill Kamvalok Adaptor A) 634B-0140 Dust Cap fits 633AST-0150 Adaptor B) 634B-0150 Dust Cap fits 633AST-2061 or 633AST-0200 Adaptor C) 634B-0160 Dust Cap fits 1611AN-0200 or 633ST-0250 or 1611AN-2040 or 1612AN-2040 Adaptors D) 634B-0170 Dust Cap fits 1611AN-3060 or 1612AN-3060 Adaptors 22 23 24 1711D / 1712D Series Kamvalok Coupler 1711T-7085-EVR Cap or 1711LPC-0300 Low Profile Cap 144TA/444TA Series Tank Alarm (optional / see Note below) 1611AV Vapor Recovery Adaptor 61VSA Series Vapor Recovery Adaptor 62M Series Monitoring Probe Cap & Adaptor FSA-400 Face Seal Adaptor 22 25 34 24 23 35 36 PAGE 40 38 39 37 38 35 21-22 36 21 26 26 19-20 20 33 33 34 34 41 18 22 1 2 3 4 5 6 7
19
2" Nipple (not supplied)
23
Fill Pipe
16
2" Nipple (not supplied)
24
TOP OF AST (not supplied)
8 9 10 11
6
2" Pipe (not supplied) TOP OF AST (not supplied)
22 12 17 15 20 21
12 13 14
D
10
13
TOP OF AST (not supplied)
15 16 17 18 19 20
12"
11
Direct fill drop tubes shall be cut at 45 angle, with top of cut no greater than 12" from the bottom of the tank (Or if outside the State of California, per local requirements)
21
21-22
NOTE: The OPW 200TG and 144TA/444TA are not required for EVR compliance, but if a tank gauge or tank alarm is used on your tank then these two OPW products are the only CARB AST EVR certified tank gauge and alarm.
25 26 27 28
24
To Pressure Vacuum Vent
B
1 3 4
C
Vapor Return Fill Pipe
30 34
15
31
32 33 2 8 17 35
27 28 29 26
29
28 26 29 25
A
5
B
9
1 2
TOP OF AST (not supplied)
PRODUCT KEY
821 Series Solenoid Valve 82RV Series Pressure Relief Valve 21BV Series Ball Valve 199ASV Series Anti-Siphon Valve
38 38 39 37 26 26 35 36 33 34 34 19-20 33 20 41 18 34 22
3
2" Nipple (not supplied)
Conduit To Remote Alarm
4 5 6
301 Series Emergency Vent - NPT Mount (See Vent Size Configuration Guide on page 15) 301 Series Emergency Vent - Flanged Mount (See Vent Size Configuration Guide on page 15) 62M Series Monitoring Probe Cap & Adaptor FSA-400 Face Seal Adaptor 200TG-ENG Series Tank Gauge (optional / see Note below) TGTA-0400 4" Gauge/Alarm Combo Fitting 44TA-LLFS Liquid Level Float Switch 61fSTOP-XXXX Series Overfill Prevention Valve 61T Series Drop Tube 61FT Series Drop Tube 175 Series Swing Check Valve 6211R Series Remote Spill Container 144TA/444TA Series Tank Alarm (optional / see Note below) 1611AN-0200 or 1612AN-0200 - 2" Remote Fill or 1611AN-0300 or 1612AN-0300 - 3" Remote Fill Kamvalok Adaptor A) 634B-0140 Dust Cap fits 633AST-0150 Adaptor B) 634B-0150 Dust Cap fits 633AST-2061 or 633AST-0200 Adaptor C) 634B-0160 Dust Cap fits 1611AN-0200 or 633ST-0250 or 1611AN-2040 or 1612AN-2040 Adaptors D) 634B-0170 Dust Cap fits 1611AN-3060 or 1612AN-3060 Adaptors 1711D & 1712D Series Kamvalok Coupler 1711T-7085-EVR Cap or 1711LPC-0300 Low Profile Cap 1611AV Vapor Recovery Adaptor 61VSA Series Vapor Recovery Adaptor S100 & 102 Series Hose Retractors OPW Dispenser Pedestal Flexible Piping Systems & Entry Fittings Commando Flexible Connectors Underground Containment Systems Probes & Sensors for Liquid & Vapors Automated Fuel Control System Automatic Tank Monitoring & Leak Detection See OPW 2011 Product Catalog for Details
Fill Pipe
6
TOP OF AST (not supplied)
10
7 8 9 10 11 12 13
C
16
22 or 23 21
12
11
14 15 16 17 18
13
14
19 12" 20 21 22 23
21-22
22 25 24 23 43-44 46
17
Direct fill drop tubes shall be cut at 45 angle, with top of cut no greater than 12" from the bottom of the tank (Or if outside the State of California, per local requirements)
18
19
20
NOTE: T he OPW 200TG and 144TA/444TA are not required for EVR compliance, but if a tank gauge or tank alarm is used on your tank then these two OPW products are the only CARB AST EVR certified tank gauge and alarm.
32* 33*
34* 35*
30* 31*
B A*
11
C
Vapor Return Fill Pipe
18
D
30
2 27
12
29
31 3 27
29
29
31
29
28
A*
4 5 6
B
9
C
15
1 2
TOP OF AST (not supplied)
2" Nipple
PRODUCT KEY
21BV Series Ball Valve
39 38 24 21-22 36 21 35 33 26 26 35 36 19-20 20 33 34 34 41 18 34 22
82RV Series Pressure Relief Valve PDT-411 Double-Tapped Tank Bung Fitting 634B-0150 or 634BK-0090 Cap 204247 Dedicated Gauging Port 633AST-0200 Adaptor 53-00XX Series Double Tapped Bushing 61T Series Drop Tube 301 Series Emergency Vent - NPT Mount (See Vent Size Configuration Guide on page 15) 301 Series Emergency Vent - Flanged Mount (See Vent Size Configuration Guide on page 15) 62M Series Monitoring Probe Cap & Adaptor FSA-400 Face Seal Adaptor 61fSTOP-XXXX Series Overfill Prevention Valve 61FT Series Drop Tube 200TG-ENG Series Tank Gauge (optional / see Note below) TGTA-0400 4" Gauge/Alarm Combo Fitting 44TA-LLFS Liquid Level Float Switch 175 Series Swing Check Valve 6211R Series Remote Spill Container 144TA/444TA Series Tank Alarm (optional / see Note below) 1611AN-0200 or 1612AN-0200 - 2" Remote Fill or 1611AN-0300 or 1612AN-0300 - 3" Remote Fill Kamvalok Adaptor A) 634B-0140 Dust Cap fits 633AST-0150 Adaptor B) 634B-0150 Dust Cap fits 633AST-2061 or 633AST-0200 Adaptor C) 634B-0160 Dust Cap fits 1611AN-0200 or 633ST-0250 or 1611AN-2040 or 1612AN-2040 Adaptors D) 634B-0170 Dust Cap fits 1611AN-3060 or 1612AN-3060 Adaptors 1711D & 1712D Series Kamvalok Coupler 1711T-7085-EVR Cap or 1711LPC-0300 Low Profile Cap 1611AV Vapor Recovery Adaptor 61VSA Series Vapor Recovery Adaptor Flexible Piping Systems for Fuel Oil & Generator Applications Underground Containment Systems Entry Fittings & Test Boots
3
Conduit To Remote Alarm
(not supplied)
4 5 6 7 8 9 10
Fill Pipe
10
16
TOP OF AST (not supplied)
7
TOP OF AST (not supplied) 2" Pipe (not supplied)
11 12 13
13 25 or 26 24
17
14 15 16
19
17 18 19 20 21 12"
14
20
22
21-22
23
*NOTE: Per local & state jurisdiction
requirements.
21
22
Direct fill drop tubes shall be cut at 45 angle, with top of cut no greater than 12" from the bottom of the tank (Or if outside the State of California, per local requirements)
23 24 25 26 27 28 29
10
NOTE: The OPW 200TG and 144TA/444TA are not required for EVR compliance, but if a tank gauge or tank alarm is used on your tank then these two OPW products are the only CARB AST EVR *See OPW 2011 Catalog or visit: www.opwglobal.com certified tank gauge and alarm.
30 31
Automatic Tank Monitoring & Leak Detection Equipment Probes & Sensors for Liquid & Vapors
11
The only Above Ground Storage Tank (AST) products in the industry to be certified by CARB
CARB REQUIRED PRODUCTS
A
3
1 2
Suction Pump
4
NOTE: The 61T Series Drop Tube must be ordered when using a 200TG Tank Guage
A
5
C
11
D
17
The only Above Ground Storage Tank (AST) products in the industry to be certified by CARB
CARB REQUIRED PRODUCTS
OPW PART / DESCRIPTION PAGE
12 18 13
4" Nipple (not supplied)
62M Series Monitoring Probe Cap & Adaptor FSA-400 Face Seal Adaptor 200TG-ENG Series Tank Gauge (optional / see Note below) 61T Series Drop Tube 301 Series Emergency Vent - NPT Mount (See Vent Size Configuration Guide on page 15) 301 Series Emergency Vent - Flanged Mount (See Vent Size Configuration Guide on page 15) 1711T-7085-EVR Cap 1611AV Vapor Recovery Adaptor 1711LPC-0300 Low Profile Cap 61VSA Series Vapor Recovery Adaptor 1711D / 1712D Series Kamvalok Coupler A) 634B-0140 Dust Cap fits 633AST-0150 Adaptor B) 634B-0150 Dust Cap fits 633AST-2061 or 633AST-0200 Adaptor
35 36 33 33 26 26 25 24 25 23 22
19
2 3 4
5 6 7 8
14
with 1DK-2100EVR Drain Valve TOP OF AST (not supplied)
20
9 10 11
B
7
Any Combination
15
12
C) 634B-0160 Dust Cap fits 1611AN-0200 or 633ST0250 or 1611AN-2040 or 1612AN-2040 Adaptors D) 634B-0170 Dust Cap fits 1611AN-3060 or 1612AN-3060 Adaptors
21-22
OR
10
13
16
1611AN-2040 or 1612AN-2040 - 2" Direct Fill or 1611AN-3060 or 1612AN-3060 - 3" Direct Fill Kamvalok Adaptor 331 or 332 Series Spill Container 61fSTOP-XXXXT Series Overfill Prevention Valve 61FT Drop Tube 634B-0150 or 634BK-0090 Cap 204247 Dedicated Gauging Port 633AST-0200 Adaptor 53-00XX Series Double Tapped Bushing
22 17 19-20 20 21-22 36 21 35
14 15
Direct fill drop tubes shall be cut at 45 angle, with top of cut no greater than 6" from the bottom of the tank (Or if outside the State of California, per local requirements)
16 17 18 19 20
NOTE: The OPW 200TG and 144TA/444TA are not required for EVR compliance, but if a tank gauge or tank alarm is used on your tank then these two OPW products are the only CARB AST EVR certified tank gauge and alarm.
12
13
B
Vapor Return Fill Pipe
A
2 3 4
27
C
18 5 28
26
7 8
B
15
23 or 24
25
The only Above Ground Storage Tank (AST) products in the industry to be certified by CARB
REQUIRED PRODUCTS
KEY 1 2 3 4
2" Nipple
19
Conduit To Remote Alarm
RECOMMENDED PRODUCTS
PAGE 40 38 39 37 38 35 21-22 36 21 26 26 19-20 20 33 33 34 34 41 18 22
(not supplied)
OPW PART / DESCRIPTION 178S Series Emergency Valve (optional) 821 Series Solenoid Valve (optional) 21BV Series Ball Valve (optional) 199ASV Series Anti-Siphon Valve (optional) 82RV Series Pressure Relief Valve (optional) 53-00XX Series Double Tapped Bushing (optional) 634B-0150 or 634BK-0090 Cap 204247 Dedicated Gauging Port 633AST-0200 Adaptor 301 Series Emergency Vent - Threaded Mount (See Vent Size Configuration Guide on page 15) 301 Series Emergency Vent - Flanged Mount (See Vent Size Configuration Guide on page 15) 61fSTOP-XXXXT Series Overfill Prevention Valve 61FT Series Drop Tube 61T Series Drop Tube 200TG-ENG Series Tank Gauge (optional / see Note below) TGTA-0400 4" Gauge/Alarm Combo Fitting (optional) 44TA-LLFS Liquid Level Float Switch (optional) 175 Series Swing Check Valve (optional) 6211R Series Remote Spill Container 1611AN-0200 or 1612AN-0200 - 2" Remote Fill or 1611AN-0300 or 1612AN-0300 - 3" Remote Fill Kamvalok Adaptor A) 634B-0140 Dust Cap fits 633AST-0150 Adaptor B) 634B-0150 Dust Cap fits 633AST-2061 or 633AST-0200 Adaptor
6
2" Nipple (not supplied)
Fill Pipe
16 26
TOP OF AST (not supplied)
5 6 7 8 9
6
2" Pipe (not supplied) TOP OF AST (not supplied)
22 12 17 20 21
10 11 12
14
10
13 14 15
16 17 18 19
13
11
20
12"
Direct fill drop tubes shall be cut at 45 angle, with top of cut no greater than 12" from the bottom of the tank (Or if outside the State of California, per local requirements)
21
C) 634B-0160 Dust Cap fits 1611AN-0200 or 633ST-0250 or 1611AN-2040 or 1612AN-2040 Adaptors D) 634B-0170 Dust Cap fits 1611AN-3060 or 1612AN-3060 Adaptors
21-22
NOTE: The OPW 200TG and 144TA/444TA are not required for EVR compliance, but if a tank gauge or tank alarm is used on your tank then these two OPW products are the only CARB AST EVR certified tank gauge and alarm.
22 23 24
1711D & 1712D Series Kamvalok Couplers 1611AV Vapor Recovery Adaptor 61VSA Series Vapor Recovery Adaptor 1711T-7085-EVR Cap or 1711LPC-0300 Low Profile Cap 144TA/444TA Series Tank Alarm (optional / see NOTE below)
22 24 23 25 34
14
27 28
62M Series Monitoring Probe Cap & Adaptor FSA-400 Face Seal Adaptor
35 36
25 26
The OPW AST Venting Guide is supplied to assist emergency venting selection for above ground storage tanks (AST). The table below contains common tank sizes and based on the Wetted Area of a horizontal cylindrical storage tank, the correct size OPW Emergency Vent . The following chart, was taken directly from NPFA 30 and UL 142.
Table 1
OPW 301 Vent Size
280 300 500 530 550 1,000 1,000 1,500 2,000 2,500 3,000 3,000 4,000 4,000 5,000 6,000 8,000 10,000 10,000 10,000 10,000 12,000 12,000 12,000 12,000 15,000 15,000 20,000 20,000 20,000 25,000 30,000
1,060 1,136 1,893 2,006 2,082 3,785 3,785 5,678 7,571 9,464 11,356 11,356 15,142 15,142 18,927 22,712 30,283 37,854 37,854 37,854 37,854 45,425 45,425 45,425 45,425 56,781 56,781 75,708 75,708 75,708 94,635 113,562
3' 38" 4' 4' 64" 64" 64" 64" 64" 64" 64" 6' 64" 6' 8' 8' 8' 8' 9' 10' 10'-6" 8' 9' 10' 11' 8' 8' 10' 10'-6" 11' 10'-6" 10'-6"
0.914 0.965 1.219 1.219 1.626 1.626 1.626 1.626 1.626 1.626 1.626 1.828 1.626 1.828 2.438 2.438 2.438 2.438 2.743 3.048 3.200 2.438 2.743 3. 048 3.352 2.438 2.438 3.048 3.200 3.352 3.200 3.200
5'-2" 5' 5'-5" 6' 6' 10'-8" 6' 9' 12' 15' 18' 14' 24' 19' 13'-4" 16' 21'-4" 27' 21' 17' 15'-7" 32' 25' 20'-6" 17' 40' 23'-5" 34'-2" 31' 28' 38'-6" 46'-3"
1.574 1.524 1.651 1.828 1.828 3.251 1.828 2.743 3.657 4.572 5.486 4.267 7.315 5.791 4.064 4.876 6.502 8.229 6.400 5.181 4.749 9.753 7.620 6.248 5.181 13.192 7.137 10.414 9.448 8.534 11.734 14.097
47 49 69 71 75 119 109 147 184 222 259 240 335 311 326 376 477 584 540 518 515 678 625 600 583 829 703 922 896 868 1,082 1,274
4.366 4.552 6.410 6.596 6.967 11.055 10.126 13.657 17.094 20.624 24.062 22.297 31.123 28.893 30.286 34.932 44.315 54.255 50.168 48.124 47.845 62.988 58.064 55.742 54.162 77.017 65.311 85.657 83.241 80.640 100.52 118.36
49,520 51,640 72,650 74,750 78,950 124,950 114,450 154,350 193,200 223,320 243,680 233,400 281,100 270,060 276,960 300,480 344,340 385,920 369,200 360,840 359,700 420,080 401,000 392,000 385,540 470,990 429,020 499,820 491,760 483,080 537,530 568,100
1,402 1,462 2,057 2,117 2,236 3,538 3,241 4,371 5,471 6,324 6,900 6,609 7,960 7,647 7,843 2,364 9,751 10,455 10,218 10,186 11,895 11,355 11,100 10,917 13,336 12,148 14,153 13,925 13,679 15,221 16,087
4" 4" 4" 4" 4" 6" 6" 6" 6" 6" 6" 6" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 8" 10" 10" 10" 10" 10" 10" 10"
15
**EXAMPLE:
Given: Tank capacity is 10,000 gallons; 10 feet in diameter x 17 feet long. Table 2From TABLE 1: WA = 518 sq. ft. If not in the table, do the following to calculate the wetted area:
Table 2 Wetted Area vesus Cubic Feet of Free Air Per Hour
(14.7 PSIA and 60)
pd 2 + p dl 2
sq. ft.
20 30 40 50 60 70 80 90 100 120 140 160 180 200 250 300 350 400 500 600 700 800 900 1,000 1,200 1,400 1,600 1,800 2,000 2,400 >2,800
sq. m.
1.858 2.787 3.716 4.645 5.574 6.503 7.432 8.361 9.290 11.148 13.006 14.864 16.723 18.581 23.226 27.871 32.516 37.161 46.452 55.742 65.032 74.322 83.613 92.903 111.48 130.06 148.64 167.23 185.81 222.97 > 260.13
CFH
21,100 31,600 42,100 52,700 63,200 73,700 84,200 94,800 105,000 126,000 147,000 168,000 190,000 211,000 239,000 265,000 288,000 312,000 354,000 392,000 428,000 462,000 493,000 524,000 557,000 587,000 614,000 639,000 662,000 704,000 742,000
CMH
597.48 894.81 1,192.13 1,492.29 1,789.62 2,086.95 2,384.27 2,684.43 2,973.26 3,567.92 4,162.57 4,757.23 5,380.20 5,974.85 6,767.72 7,503.96 8,155.25 8,834.85 10,024.16 11,100.20 12,119.61 13,082.38 13,960.20 14,838.02 16,338.82 16,621.98 17,386.54 18,094.46 18,745.75 19,935.06 21,011.10
Step 2 If the tank size is in the chart, use the supplied CFH values to determine the emergency vent size needed in TABLE 1. If not in the charts, continue the following example: Using 518 square feet, the cubic feet per hour (CFH) can be found using TABLE 1. Since 518 falls between the values of 500 and 600, interpolation is necessary as follows: Difference: 600 sq. ft. -500 sq. ft. 100 sq. ft. 392,000 CFH -354,000 CFH 38,000 CFH See TABLE 2 for additional CFH values.
38,000 x ; x =6,840 CFH 100 518-500 Total CFH required = 354,000 CFH + 6,840 CFH = 360,840 CFH
Step 3 Vent selection: using TABLE 1, find the range in which 360,840 CFH falls. The tables show that an 8" emergency vent is needed.
SOURCE: Flamable and Combustible Liquids Code 30, NFPA. Interpolate for immediate values.
16
POMECO/OPW 331AST & 332AST DIRECT-FILL ABOVEGROUND STORAGE TANK SPILL CONTAINERS
POMECO/OPW 331AST & 332AST Direct-Fill Above Ground Storage Tank Spill Containers
POMECO/OPW Direct-Fill AST Spill Containers are designed to prevent spilled product from entering soil near the fill and vapor return riser connections on an above ground storage tank during normal tank filling operation. The spill containers catch spillage to help prevent soil contamination and groundwater pollution. POMECO/OPW Direct-Fill AST Spill Containers thread on the top of an above ground tank and allow for drainage of spilled product back into the tank.
B
Features
u Easy Installation 4" and 6" NPT threaded base screws directly to the tank riser pipe. No further adjustments are needed. u Integral Drain Valve allows highspeed drainage of spilled product back into the tank. u Capacity available in 7-gallon (26.5 liter) container capacity. Larger 7-gallon capacity spill containers provide additional clearance for 61STOP Overfill Prevention Valves (3.5 gallon-221 only). u Rain-Shedding Cover Design hooded cover design helps prevent water or snow entry by extending the lip of the cover over the body of the spill container. u Welded-Hinge, Lockable Hatch the cover includes a provision for a padlock and a welded-hinge assembly for added security. u 12 Gauge Epoxy-Powder Coated Construction heavy-duty materials, compatible with hydrocarbons, for long service life and added security.
331AST
u 332AST Spun Steel Design spun steel construction provides a lightweight, one-piece design for easy installation and a clean, sleek appearance on aboveground tanks. u All Models Are ULC Listed clearly labeled to identify the listing. u CARB EVR Certified Replacement Parts:
Part # 1DK-2100-EVR Description Drain Valve
331-AST
B
u 331ASTHeavyweight, Welded Base Design all versions have cast-iron base and 12-gauge steel walls (model 331) and 14-gauge steel wall (model 332) provide solid strength for heavy-duty applications.
331AST and 332AST Spill Containers Instruction Sheet Order Number: 203168
Ordering Specifications:
332-AST CARB APPROVED AST EQUIPMENT Product No. 331-ASTW74 Description Welded, 7 gallon, 4" NPT Welded, 7 gallon, 6" NPT Spun, 7 gallon, 4" NPT Spun, 7 gallon, 6" NPT Liters Welded, 26.4 liter, 4" NPT Welded, 26.4 liter, 6" NPT Spun, 26.4 liter, 4" NPT Spun, 26.4 liter, 6" NPT
Dimensions
Capacity
Model # gal. 331 332 7 7 liter 26.5 26.5 in. 15 14
A
cm 38 35 in. 17 17
B
cm 43 43
CARB Certified AST Phase 1 Enhanced Vapor Recovery (EVR) System EO-VR 401-B
u Easy Installation a 4" flexible boot on the back panel allows for a quick, simple connection to the remote fill or vapor lines. Optional reducer inserts are available to accommodate 3" and 2" piping connections. u Models to Accommodate Various Fill Pipe Configurations available in 15, 20 and 30-gallon container capacity. Smaller 15-gallon models are designed for a single-fill or vapor return connection. Larger 20 and 30-gallon models accept both fill and vapor return piping in a dual-port configuration. The 30-gallon model will accommodate both fill and vapor return piping in a singleport configuration and allow the use of 3" Dry Disconnects (OPW 1611AN and 1711D) in a dual-port configuration. u Rain-Shedding Cover Design hooded cover design helps prevent water or snow entry by extending the lip of the cover over the body of the spill container. u 12-Gauge Epoxy-Powder Coated Steel or Stainless Steel Construction heavy-duty materials, compatible with hydrocarbons, for long service life and added security.
6211-R
u Welded-Hinge, Lockable Hatch cover includes a provision for a padlock and a welded-hinge assembly for added security. u Easy Product Drainage lockable ball valve drain provides for quick and easy product removal. u Height Adjustable adjustable legs enable the spill container to be set at a variety of heights, from 161/2" to 30". Each leg is independently adjustable to account for uneven ground conditions. u CARB Certified u Custom Sizes Available Upon Request.
B2 L B3 LD B4 N N ND
L A djustable legs and No base drain valve LD Adjustable legs with base drain valve N No legs and No base drain valve ND No legs with base drain valve
POMECO/OPW Remote-Fill AST Spill Containers are designed to prevent spilled product from entering soil near the remote, horizontal-fill and vapor return connections on an above ground storage tank during normal tank filling operation. The spill containers catch spillage to help prevent soil contamination and groundwater pollution. POMECO/OPW Remote-Fill AST Spill Containers slip on the remotefill and vapor return piping connected to an above ground tank. Compatible with methanol, ethanol, jet and AV-Gas fuels.
E F
Ordering Chart:
6 R 211 15 0 211SS 20 1 30 2
211 12 Gauge PowderCoated Steel Construction 211SS Stainless Steel Construction 15 15 Gallon Capacity 20 20 Gallon Capacity 30 30 Gallon Capacity 0 No entry holes 1 1, 4" entry hole 2 2, 4" entry holes (30 Gallon Only) B Booted entry fittings in holes N No fittings in holes
Replacement Parts
Part # 201758 Description 4 x 2 Reducer Insert 4 x 3 Reducer Insert Nitrile (Fuel-Resistant) Boot Aluminum Flange Fullport 3/4"
Dimensions
15Gallon in.
A B C D E F G 181/4 738 1358 1 16 /2 to 30 181/4 91/8 47 to 601/2
20 Gallon cm in.
24 71/2 161/2 1 16 /2 to 30 24 12 561/2 to 80
30 Gallon cm in.
21 101/2 161/2 1 16 /2 to 30 34 91/2 561/2 to 80
201759
cm
53 27 42 42 to 76 86 24 144 to 203
46 19 35 42 to 76 46 23 119 to 154
18
POMECO/OPW 211-RMOT
Features
Materials
Valve Body, Adaptor and Collar: Cast aluminum Poppet: Cast aluminum, hard-coated Cam: Stainless steel Follower: Brass Shaft: CRSzinc-plated Bearing: Sintered bronze Float: Closed-cell Nitrile Nipple: 2" - 3" schedule 40 steel pipe Lower Nipple: 2" - 3" schedule 40 steel pipe with Duragard coating
61Stop-1000 61Stop-2000 61Stop-3050
61Stop-1000T
61Stop-2000T
61Stop-3050T
Features
u A Special Crossbar Tank-Inlet Adaptor is provided with each Stopper to provide for tight-fills and help prohibit openfills. Mounting hardware, upper drop tube and 14" lower drop tube provided (longer-length drop tubes can be purchased or added). u Completely Automatic Operation no pre-checks to perform, no resets, and no overrides to be broken or abused. Direct or Remote-Fill Compatible u fuel delivery couplers can be connected directly to the 61STOP, or steel pipe can be threaded into the top of the valve and piped to a remote location where the couplers are contained in a 211-RMOT Spill Container. u Integral Anti-Siphon Valve drain vents on the 61STOP act as an anti-siphon, by introducing air/vapor into the fill line after the valve actuates, to help isolate the tank from a potential siphon due to a broken or leaking remote-fill pipe. u 150 psi (10 bar) Pressure Rated* with Low Pressure Drop to enable quick, safe delivery of fuel into the tank. u 25 GPM (95 lpm)Minimum Flow Rate Required. u UL and ULC Listed to satisfy Third Party accreditation requirements of many jurisdictions. u CARB Approved VR-401-A; VR-401-B
* OPW does not recommend pumping pressures above 100 psi for Class 1B fuels or remote applications and we make no warranties for products used in conjunction with the 61STOP. N OTE: OPW recommends the use of the 61STOP with clean product only. Debris and other products such as contaminated waste oil may cause improper operation of the valve. NOTE: The 61Stop can be used in gravity drop provided the minimum flow rate is maintained. A tight shut-off is not achieved in the closed position. However with a minimum tank size of 1,000 gallons, the leak rate will provide a 30-minute warning before the tank is full.
61Stop-2"
61Stop-3"
A B
C FLOW RATE - GPM FLOW RATE - GPM D F cm 10 5 13 in. 6 cm 15.2 n/a n/a
D E
D cm in.
31
61Stop-1000
10 25.4 10 25.4
/2
A B 271/2" C D E
7.6 105/8 27
n/a n/a
61Stop-3050
CARB APPROVED AST EQUIPMENT A Product # 61STOP-1000T 61STOP-2000T 61STOP-3050T Description 2" NPT with cylindrical float 2" NPT with float arm 3" NPT with cylindrical float in. cm in. 2
1
B cm 5.1 in. 9
C cm in.
D cm 10 5 13 in.
E cm B
10 25.4 10 25.4 10 /8 27
5
22.4 31516
31
B C D
/2
NOTE: When ordering a CARB EVR Certified OPW 61 STOP, the Kamvalok Adaptor must be ordered separately. Refer to page 22.
61FSTOP-1000, 100M, 200M Instruction Sheet Order Number: H12676M 61FSTOP-2000 Instruction Sheet Order Number: H13337M 61FSTOP-3000, 3050, 305A Instruction Sheet Order Number: H13315M 61FT-0312, 0206 Instruction Sheet Order Number: H14428PA 61FSTOP-1000T, 2000T, 3050T Instruction Sheet Order Number: 203163
61Stop-3050T
CARB APPROVED AST EQUIPMENT Product # 61FT-0206 61FT-0312 Description 2" x 6' Drop Tube Kit 3" x 12' Drop Tube Kit
20
Kamlok Couplers The 633BD has a Kamlok Coupler on one end and external threads on the other end. This coupler should be threaded into an OPW 190 Nozzle and then coupled to the 61STOP for filling ASTs.
Ordering Specifications
Elbow/Thread Product # 633BD-1261 633B-0150 in. 2 x 1 /2
1
mm 51 x 38 51 x 51 633B Coupler
2x2
Tank Inlet Spout Adaptors With Crossbar The 633AST Series Adaptors, with a boss installed across the inlet, are designed to prohibit open-fills. Adaptors are supplied with the 61STOP to provide for tight-fills.
Ordering Specifications
OPW 61fSTOP Overfill Prevention Valve Elbow/Thread Product # 633AST-2061 633AST-3061 in. 2x2 3x3 mm 51 x 51 77 x 77 633AST Spout Adaptor
The 633AST is an adaptor that can be threaded onto a 297 Spout. The spout and adaptor assembly may then be attached to a 190 Nozzle equipped with a 633BD Kamlok coupler for open filling of ASTs when a 61STOP is not installed.
Ordering Specifications
CARB APPROVED AST EQUIPMENT OPW 190 High-Flow Nozzle OPW 633BD Kamlok Coupler Pomeco 211AST AST Spill Container OPW 633AST Spout Adaptor OPW 297 Aluminum Spout Elbow/Thread Product # 633AST-0150 633AST-0200 633AST-0250 633AST-0300 633AST-0400 in. 1.5 x 1.5 2x2 2.5 x 2.5 3x3 4x4 mm 38 x 38 51 x 51 64 x 64 76 x 76 102 x 102 633AST Spout Adaptor
Dust Caps The 634B Dust Caps are installed on 633AST Adaptors when not in use. The 634B is designed to deter dust, debris and water from entering the tank.
Ordering Specifications
CARB APPROVED AST EQUIPMENT Product # 634B-0140 634B-0150 634B-0160 634B-0170 634B-0180 Description For 633AST-0150 Caps 633AST-2061 or 633AST-0200 Adaptor Caps 1611AN-0200 or 633AST-0250 or 1611AN-2040 or 1612AN-2040 Adaptors Caps 61STOP (633AST-3061) or 366AST-0300 or 1611AN-3060 or 1612AN-3060 Adaptors 1611AN-0300 Kamvalok Adaptor or 633AST-0400 Adaptor in. 1-1/2 2 2-1/2 3 4 mm 38 51 64 77 Dust Cap 103
21
For more information contact OPW Customer Service at 1-800-422-2525; International call 1-513-870-3315.
Installed onto the 61STOP overfill prevention valve. Contains an internal spring- loaded valve assembly that automatically closes to help prevent fuel spillage.
Ordering Specifications
Product # CARB APPROVED AST EQUIPMENT Seal in. Direct Fill with Buna seal Direct Fill with Viton seal Direct Fill with Buna seal Direct Fill with Viton seal 2 2 3 3 mm 51 51 77 77 Kamvalok Adaptor for Direct Fill 1611AN-2040 1612AN-2040 1611AN-3060 1612AN-3060
Fuel Delivery Couplers and Accessories are designed to connect fuel delivery transport truck hoses or nozzles to the fill pipe of an aboveground storage tank.
OPW 1611AN or 1612AN Kamvalok Adaptor OPW 1711D or 1712D Kamvalok Coupler
Poppeted Kamvalok Fill Adaptors The 1611AN Series Kamvalok Adaptor is installed at the fill pipe and replaces the 633AST. The 1611AN contains an internal spring-loaded valve assembly that automatically closes to help prevent fuel spillage. The 1611AN mates with the 1711D Coupler to open the spring-loaded valve and proceed with a delivery.
Ordering Specifications
CARB APPROVED AST EQUIPMENT Product # 1611AN-0200 1611AN-0300 1612AN-0150 1612AN-0200 1612AN-0300 Seal Remote Fill with Buna Seal Remote Fill with Buna Seal Remote Fill with Viton Seal Remote Fill with Viton Seal Remote Fill with Viton Seal in. 2 3 11/2 2 3 mm 51 77 38 51 77 Poppeted Kamvalok Couplers for Remote Fill
* Thread and Kamvalok same size 1611AN Adaptor Instruction Sheet Order Number: 204016
Poppeted Kamvalok Couplers The 1711D Series Kamvalok Couplers are installed on the fuel delivery transport truck hose and mate with the 1611AN Adaptors. The combination of the 1711D and 1611AN enable dry connection and dry disconnection of delivery fittings to help prevent accidental spillage of product.
Ordering Specifications
CARB APPROVED AST EQUIPMENT Product # 1711D-1075 1711D-1080 1712D-1085 1712D-1090 1712D-1095
in. 2 3 11/2 2 3
Lockable Dust Caps The 634BK-0090 is a 2" lockable dust cap for the 61STOP. It will cap off any 2" 633AST Tank Inlet Spout Adaptor and offers the added feature of being lockable.
Viton
Ordering Specifications
CARB APPROVED AST EQUIPMENT Product # Description in. 2 3 4 mm 51 77 103 634BK-0090 Caps 633AST Adaptor 634BK-0100 Caps 633AST Adaptor 634BK-0200 Caps 633AST Adaptor
* Thread and Kamvalok same size H32116PA Coupler Instruction Sheet Order Number: 204016
Dust Plugs The 634A Dust Plug is installed in the end of the 1711D, when not in use. The 634A is designed to help prevent dust, dirt and debris from damaging the internal components of the 1711D Kamvalok Coupler.
Ordering Specifications
Product # 634A-0160 634A-0180 Description Plugs 1711D or 1712D - 2" Kamvalok Coupler Plugs 1711D or 1712D - 3" Kamvalok Coupler
22
Materials
Adaptor: Bronze Base: Bronze Retaining ring: Conductive nylon Set screws: Stainless steel Seals: Nitrile
Features
u Dual Seals ensure a vapor and liquid-tight seal. u Conductive, Self-Lubricating Retaining Rod ensures maintenance-free, reliable service life.
u Same Internal Dimension as Standard 633T Adaptors to minimize pressure drop and maximize flow rates for quick product delivery. u Self Guiding Poppet for consistent tight seal.
4 45/64" 120mm
5 7/8" 149mm
OPW 61SA-TOOL
The 61SA-TOOL is a wrench designed to thread on the 61SA Fill and 61VSA Vapor Adaptors. The OPW 61SA-TOOL Adaptor installation tool is required to ensure proper installation of OPW rotatable swivel adaptors, thread-on spill containers, fill and vapor adaptors,TC-400 torque cap for pipe nipples and threaded riser adaptors as per EVR requirements. The 61SA-TOOL includes provisions for the use of a torque wrench to facilitate accurate installation and testing.
5 1/2" Across Lugs 139.7mm
61SA-TOOL
23
Body: C lear anodized aluminum or cast bronze Stem: Chrome-plated steel Stem Guide: Acetal resin Spring: Stainless steel Gasket: Nitrile
1611AV 3" x 4" (76 x 102mm)
The OPW 1611AV and 1611AVB are poppeted adaptors, designed to mate with a vapor recovery elbow, for returning gasoline vapor to the tank truck during a fuel delivery to an underground tank.
Ordering Specifications
Product # in. 1611AV-1605 1611AV-1620 1611AVB-1625 3 3 3 Elbow Size mm 76 76 76 3 4 4 Riser Thread in. mm 76 102 102 lbs. 2.91 3.25 7.97 kg 1.32 1.48 3.62 Clear Anodized Aluminum Clear Anodized Aluminum Cast Bronze Body Material
Replacement Parts
Key 1 Not Shown 2 3 Part # C02642M H15294M H04145M H04150M H08989M Description Bridge Guide Screw (3") (76mm) Gasket (3") (76mm) Gasket (3"x 4") (76 x 102mm) Spring 5 1/8" 128mm 5 7/16" 138mm
PDT-411
Ordering Specifications
Product # PDT-411 Description 4" x 1" x 1" Double Tap Bushing
24
Materials
Materials
Body: Duratuff Pins: Stainless steel Links: Duratuff Gasket:Nitrile Color: Orange
1711T Cap
Ordering Specifications
Product # 1711T-7085-EVR in. 3 mm 76 lbs. 1.1 kg .50
7" 178mm.
Replacement Parts
Part # H10886M Description Nitrile Gasket Effective height above adaptor 11932"
2 9/16" 65mm.
Materials
Cap: Cast zinc alloy (powder-coated orange) Lever: Ductile iron Gasket:Nitrile
1711LPC Cap 8 7/16" Effective height above adaptor 12"
Ordering Specifications
Product # 1711LPC-0300 in. 3 mm 76 lbs. 3.5 kg 1.59
Replacement Parts
Part # H15005M Description Nitrile Gasket 63/4" REF. 6.873" 174.5mm
3 5/16" REF.
7/8" 23mm
Look for this label for authentic OPW EVR Approved products.
Lid: Cast iron with powder-coated finish Body: Aluminum Shaft: Zinc-plated steel O-Ring: Buna-N
301 SCFH@21/2PSI (0.17 bar) 4 "- 101,000 6 "- 250,000 8 "- 471,000
Features
u Automatically Resets weighted cast iron cover reseats once the pressure in the tank is relieved. u Aluminum Body and Cast Iron Lid u Epoxy Powder-Coated Cover prevents rusting of the cover to protect expensive finishes on ASTs. uU L Listed to satisfy third party accreditation requirements of many jurisdictions. uC ARB Certified AST Phase 1 Enhanced Vapor Recovery (EVR) System
301 Series Instruction Sheet Order Number: 203568
Ordering Specifications
CARB APPROVED AST EQUIPMENT Pressure Model # 301-3080 301M-3081 301-3160 301M-3161 301-4080 301M-4081 301-4160 301M-4161 301-6080 301M-6081 301-6160 301M-6161 301-8080 301M-8081 301-8160 301M-8161 301F-8085 301F-8165 301F-1085 in. 3 3 3 3 4 4 4 4 6 6 6 6 8 8 8 8 8 8 10 mm 76 76 76 76 101.5 101.5 101.5 101.5 152 152 152 152 203 203 203 203 203 203 254 Setting 8 oz. 8 oz. 16 oz. 16 oz. 8 oz. 8 oz. 16 oz. 16 oz. 8 oz. 8 oz. 16 oz. 16 oz. 8 oz. 8 oz. 16 oz. 16 oz. 8 oz. 16 oz. 8 oz. Mounting Connection Female NPT Male NPT Female NPT Male NPT Female NPT Male NPT Female NPT Male NPT Female NPT Male NPT Female NPT Male NPT Female NPT Male NPT Female NPT Male NPT Flange Flange Flange in. 4.7 4.7 5.7 5.7 4.9 4.9 6.1 6.1 5.9 5.9 7.4 7.4 6.2 6.2 7.8 7.8 6.2 7.8 6.5 A mm 119.4 119.4 144.8 144.8 124.5 124.5 154.9 154.9 149.9 149.9 188 188 157.5 157.5 198.1 198.1 157.5 198.1 165.1 in. 5.1 5.1 5.1 5.1 6.1 6.1 6 6 8.1 8.1 8.1 8.1 10.1 10.1 10.1 10.1 10.1 10.1 13 B mm 129.5 129.5 129.5 129.5 154.9 154.9 152.4 152.4 205.7 205.7 205.7 205.7 256.5 256.5 256.5 256.5 256.5 256.5 330.2 Weight lbs. 6.7 6.7 11.4 11.4 10.6 10.6 18.1 18.1 20.9 20.9 37.5 37.5 33.9 33.9 61.9 61.9 41.8 70 65.2 kg 3 3 5.2 5.2 4.8 4.8 8.2 8.2 9.5 9.5 17 17 15.4 15.4 28 28 19 31.8 29.6
The OPW 301 Emergency Vent is designed to prevent an above ground storage tank from becoming overpressurized by providing high-capacity venting in the event of a fire or blockage. The 301 is a weighted, mushroom-style emergency vent. When the AST builds pressure, the weighted cast iron lid is forced up off its seat to relieve the pressure. When pressure is relieved, the lid lowers and is automatically reset. The appropriate 301 Series vent is determined by the emergency venting capacity requirements of the AST and the type of connection at the tanks emergency vent opening. The OPW 301 Emergency Vent is available in 4", 6", 8" and 10" openings with female NPT, male NPT or flanged connections (8"-10") to allow for easy installation in new or existing above ground tanks. Various lid pressure settings determine the initial venting of the valve.
Replacement Parts
Part # 201877 202721 203325 Description 4" Seal 6" Seal 8" Seal
26
Materials
Materials
Cover and body: Aluminum Link: Duratuff Spring: Stainless steel Sealing surface: Teflon-coated aluminum
Features
u Lightweight Construction allows for safe, easy installation on large aboveground tanks. u Spring-Loaded, O-Ring Sealed Cover with Teflon-Coated Seat ensures smooth, vapor-tight sealing surface and reliable service life. u Full-Bore, High-Capacity Upward Venting enables smaller diameter vents, with higher venting capacity, to be used on ASTs when compared to weighted, mushroom-style vents. u Aluminum Cover and Body with Stainless Steel Components corrosion-resistant construction to protect expensive finish or epoxy coatings on ASTs. u Mounts Vertical or Horizontal.
kg .95 1.6 2.3 A B C
u Alerts Tank Operators of Possible Venting Problems when the emergency vent is actuated, the lid remains open for inspection until manually reset. The actuation of the emergency vent indicates abnormal excessive pressure build-up in the tank due to either a blockage in the normal tank vent or in the event of a rapid expansion of vapors possibly from a fire. u Easy Vent Reset no extra parts required. Simply push the vent lid closed until an audible click is heard, indicating the vent is back in operation. u UL Listed to satisfy Third Party accreditation requirements of many jurisdictions. Dimensions 202
4" (102mm) in. mm 23/8 4 61/2 60 102 165 6" (152mm) in. mm 23/8 5 89/16 60 127 218 8" (203mm) in. mm 25/8 5 /8
7
Ordering Specifications
A Model # 202-0640 202-0660 202-0680 in. 4 6 8 mm 102 152 203 lbs. 2.05 3.55 5.1
67 149 273
103/4
Top/Body: Polypropylene Base: Anodized aluminum Poppet: Anodized aluminum Screen: Stainless steel mesh Gasket: Closed cell foam
623V Vent Must Be Mounted Vertically
Features
u Pressure/Vacuum Setting 2.5" to 6" water column pressure settings and -6" to -10" water column vacuum settings are factory preset and tested. u Reliable Service cycle tested to the equivalent of 80 years of service in the most severe environment without leakage problems. uC orrosion-Resistant Construction a Duratuff composite body ensures a long service life. uE asy Installation the 623V is available in 2" and 3" threaded versions. u Complies with NFPA 30 Requirements for venting gasoline vapors upward. uM anifold Vent Pipes vent pipes may be manifolded to produce a single Pressure Vacuum Vent line. The 623V exceeds Californias requirements of a maximum vapor leak rate of 0.17 SCFH at 2.00 inches H2O. uH igh Maximum Flow Rate 6450 SCFH at 2 psi (0.1 bar) pressure drop. eak Rate multiple pressure vacuum uL vents may be installed on a single site. The 623V exceeds California standards with a leak rate of 0.05 SCFH or less at 2.00 inches H2O. uM aintenance no tools required. A removable snap fit top allows for easy maintenance (recommended yearly). u1 00-Mesh Stainless Steel Wire Screens helps prevent debris and insects from entering the tank vent lines. An added screen installed at the base prevents debris from intruding from the vent stack. uA daptor Bushing removable hex threaded bushing designed for easy installation on NPT threaded risers. Allows easy access to lower screen. uA TEX Approved for flame arrestor applications
Pressure Vacuum Vents are installed on the top of vent pipes from underground or above ground fuel storage tanks. The vent cap and internal wire screen are designed to protect the tank vent lines against intrusion and blockage from water, debris or insects. A normally closed poppet in the valve opens at a predetermined pressure or vacuum setting to allow the tank to vent.
Conversion Table
Ordering Specifications
Product # 623V-2203 623V-3203 Description 2.5" to 6" WC Pres., -6" to -10" WC Vac. Thread-On 2.5" to 6" WC Pres., -6" to -10" WC Vac. Thread-On Identification Label Color Yellow Yellow lb. 1.55 2.20 kg .70 1.00
In H2O In Hg = Oz. PSI 14.5 0.49 0.04 27.68 0.063 1.73 (WC) (Merc) Bar 401.4 29.53 13.6 0.034 0.074 0.002 2.04 0.069 x 236.0
Replacement Parts
Part Number C05086M H14895M C05089 C05122 Description Lower Screen Upper Screen 2" Threaded Base Adaptor 3" Threaded Base Adaptor
Oz.
0.128 0.004
ATEX Approved
28
Materials
Features
Variety of Pressure/Vacuum Settings uA 3" water column, 1 oz., 8 oz., 12 oz. pressure settings and 8" water column or 1/2 oz. vacuum settings are factory preset and tested. eliable Service self-guided poppet uR assembly ensures consistent seating of the pressure/vacuum valve. uC orrosion-Resistant Construction Duratuff composite body assures a long service life. uE asy Installation 523V is available in 2" and 3" threaded versions or slip-on models that provide for attachment to the vent line with allen head screws and radial sealing O-ring.
523V
uC omplies with NFPA 30 Requirements for venting gasoline vapors upward. uH igh Maximum Flow Rate 7000 SCFH at 2 psi pressure drop.
Conversion Table
Measurement Units Bar In. Hg (Mercury) In H2O (WC) PSI Oz. In H2O In Hg = Oz. PSI 14.5 0.49 0.04 27.68 0.063 1.73 (WC) (Merc) 401.4 29.53 13.6 0.034 0.074 0.002 2.04 0.069 Bar x 236.0 x 7.843 x 0.578 x 16.00 x
0-Mesh Stainless Steel Wire Screen u4 helps prevent debris and insects from entering the tank vent lines.
Ordering Specifications
Product # 523V-1100 523V-1150 523V-3100 523V-3150 523V-2300 523V-2350 523V-2200 523V-2250 523V-3200 523V-2203 523V-2253 523V-3203 523V-3253 Description 2" 8 oz pres., 1/2 oz. Vac. Thread-On 2" 8 oz pres., 1/2 oz. Vac. Slip-On 3" 8 oz pres., 1/2 oz. Vac. Thread-On 3" 8 oz pres., 1/2 oz. Vac. Slip-On 2" 12 oz pres., 1/2 oz. Vac. Thread-On 2" 12 oz pres., 1/2 oz. Vac. Slip-On 2" 1 oz pres., 1/2 oz. Vac. Thread-On 2" 1 oz pres., 1/2 oz. Vac. Slip-On 3" 1 oz pres., 1/2 oz. Vac. Thread-On 2" 3" WC pres., 8" WC Vac. Thread-On 2" 3" WC pres., 8" WC Vac. Slip-On 3" 3" WC pres., 8" WC Vac. Thread-On 3" 3" WC pres., 8" WC Vac. Slip-On Identification Label Color Red Red Red Red Blue Blue Silver Silver Silver Yellow Yellow Yellow Yellow lb. 1.65 1.65 3.2 3.2 1.65 1.65 1.65 1.65 3.2 1.65 1.65 3.2 3.2 kg .75 .75 1.45 1.45 .75 .75 .75 .75 1.45 .75 .75 1.45 1.45
0.128 0.004
Replacement Parts
Part Number H11432M H11456M Description O-Ring for 2"Thread O-Ring for 3"Thread
Materials
Body: Aluminum O-Ring: Nitrile
523SA (BottomView) 523SA (TopView)
Ordering Specifications
Product # Description 523A-1003 3 " Thread-On Adaptor for use with 523V Pressure / Vacuum Vents 523SA-1003 3" Slip-On Adaptor for use with 523V Pressure / Vacuum Vents 523SA-1002 2" Slip-On Adaptor for use with 523V Pressure / Vacuum Vents in. 2x3 2x3 2x2 mm 51 x 76 51 x 76 51 x 51 lb. .47 .63 .31 kg .213 .286 .141
29
Cap body: High-tensile aluminum alloy construction. Has straight pipe threads with Nitrile for tight seal to tank. 2" - 111/2" NPSH threads. Dome: Plated steel Screen: 40-mesh brass
514F
Features
u 3-Pound Pressure and 1 oz. Vacuum Settings factory preset and tested to protect against product vapor loss and allow for rapid withdrawal of product from the tank. uR eliable Service precision-machined, lapped bronze pressure and vacuum seats ensure consistent seating of the pressure/vacuum valve. u Corrosion-Resistant Construction zinc/aluminum alloy body and zinc-plated steel dome assure a long service life. u Easy Installation 514F is available in 2" (111/2" NPSH) female straight threads with a Buna-N gasket. uH igh Maximum Flow Rate 3500 SCFH at 4.5 psi (0.31 bar) pressure drop. u Lockable Base - a provision for padlocking the vent to the tank is integrated into the base. Replacement Parts
Key 1 2 3 4 5 6 7 8 Part # H01967M H10096M H07355M H11432M C03991M H07356B H08380AH H07353M Description Nut Pressure Spring Screen Seal Dome Vacuum Disc Pressure Disc Vacuum Spring
OPW Utility Tank Vents are installed directly on the top of above ground storage tank or utility tank vent pipes. The vent cap is designed to protect the tank against intrusion of water, debris or insects. The 515ML incorporates a flame arrester screen for jurisdictions that require these on tanks. A normally closed poppet in the valve opens at a predetermined pressure or vacuum setting to allow the tank to vent.
A 1 2 B 3
8 7 5 6 4 F E D
Ordering Specifications
Product # 514F-3050 in. 2 mm 51 lbs. .46 kg .21
514F
Dimensions (514F)
A B C D E F in. 25/16 25/16 15 /16 2 21/32 115/16 7 /16 mm 59 75 24 67 49 11
Materials
Cap Body: High-tensile aluminum alloy construction. Has straight pipe threads with Nitrile gasket for tight seal to tank. Dome: Plated steel Screen: 40 mesh brass
515ML
1 2 3
11 10 9 8
Features
u Flame Arrestor Screen for jurisdictions that require flame arrestors on tank vents. u 5 PSI (0.34 bar) Pressure and 1 oz. Vacuum Settings factory preset and tested to protect against product vapor loss and allow for rapid withdrawal of product from the tank. u Reliable Service precision-machined, lapped bronze pressure and vacuum seats ensure consistent seating of the pressure/vacuum valve. u Corrosion-Resistant Construction zinc/aluminum alloy body and zinc-plated steel dome assure a long service life. uE asy Installation 515ML is available in 2" (111/2" NPSH) male straight threads. u High-Maximum Flow Rate 3500 SCFH at 7.5 psi (0.52 bar) pressure drop.
B
4 5 6 7B 7A D C
515ML
Key 7A 7B 8 9 10 11 Part # H11211M H03636M C03991M H07356B H08380AH H07353M Description O-Ring Cap Gasket Dome Vacuum Disc Pressure Disc Vacuum Spring
Dimensions (515ML)
in. A B C D 25/16 51/4 31/8 1 /16
15
mm 59 133 79 49
Ordering Specifications
Product # 515ML-1030 in. 2 mm 51 lbs. 1.80 kg .82
30
Materials
Materials
Body: Aluminum 40-mesh brass Screen: Set Screws: Brass
23
Features
uR eliable Service vent cap drain spouts extend outward to deter rainwater entry. u Corrosion-Resistant Construction aluminum body and cap assure a long service life. u Easy Installation 23 series is available in 2" and 3" slip-on models that provide for attachment to the vent line with set screws. u Complies with NFPA 30 Requirements for venting gasoline vapors upward. u High-Maximum Flow Rate 7000 SCFH at 2 psi (0.14 bar) pressure drop. u 40-Mesh Brass Wire Screen helps prevent debris and insects from entering the tank vent lines.
37/8" 99mm
Ordering Specifications
Replacement Parts
Part # H00122M H01967M H01969M Description Screw Nut Screen
in. 11/2 2 3
mm 38 51 76
Materials
Body: Zinc/aluminum Screen: Brass Cap: 2" - Steel 4" - cast iron Screen: 40-mesh stainless steel
113
Ordering Specifications
Product # in. 2 4 mm 51 102 lbs. .88 7.50 kg .40 3.41
Dimensions
2" (51mm) in. A B 11/2 33/4 23/4 mm 38 95 70 4" (102mm) in. 23/4 77/16 415/16 mm 70 189 125
113-0066 113-0099
For more information contact OPW Customer Service at 1-800-422-2525; International call 1-513-870-3315.
31
Part of the
systems in the world to the most reliable and accurate fuel control systems, there is no better or more comprehensive solution on the market today to ensure that you know exactly how much fuel you have and where it is going. When it
VSMART MODULE
comes to complete fuel accountability, unparalleled protection against theft and total reconciliation, OPW Fuel
DENSITY MEASUREMENT
Management Systems is Leading the Way in keeping you and your assets covered both coming and going!
Setting the industry standard in retail and commercial fueling solutions worldwide since 1892.
32 32
Materials
Enclosure: Powder-coated aluminum Swivel Base: Hard-coat aluminum Float: 304 stainless steel Lenses: Tempered borosilicate Gears: Acetal Gaskets & O-Rings: Nitrile All Hardware: Stainless steel Accuracy: + or - 2"
200TG
Features
u Vapor-Tight allows for standard tank pressure testing and sealing up to 25-psig (1.72 bar). u Angled Face improves visibility from ground on large diameter tanks. May be read easily up to 30 feet away (9.14 m). u Float Buoyancy designed to float in all approved fuels with a specific gravity of 0.65 and greater. Tank Height unit designed for use u on any horizontal or vertical aboveground tank up to 18 feet (5.5 m) in depth. Specials available upon request. u Numbering black letters on white background for ultimate contrast and better visibility. Characters stand over 1" (25 mm) tall. u Unit Measurement can be purchased in metric units to read in meters, 1/10, 1/100, or in English units to read in feet and inches. u Maintenance no annual maintenance required. U.S. Patent No.: 6,523,404 - Other u patents pending. Compatible Fuels see chart on u page 40. u Temperature Rating 120F to -40F (49C to -40C)
200TG Tank Gauge Instruction Sheet Order Number: H14912PA
u Swivel Adaptor Base allows for 360 of rotation of gauge face for easy viewing wherever needed. u Easy Installation 2" NPT-threaded base reduces labor time, and comes standard with female thread. A H11421RS may be purchased for male threaded applications. u Corrosion-Resistant Construction powder-coated die cast-aluminum body assures for long service life in many fluids.
Dimensions:
in. A B C D E 8 1/4 10 1/4 9 6 /4
3
1 /2
1
Drop Tube prevents float entanglement u in the tank, and gives the gauge a more accurate reading when turbulence is present (Drop Tubes sold separately. They are recommended for use in tanks with high turbulence, and where other piping and structures inside the tank may cause entanglement).
(Ancillary Equipment)
Product # Description lb. kg kg H11421RS 2" NPT Male x Male Nipple 1.5 0.68
Replacement Parts:
Part # C05165M H14358M H14909M Description Float Lens Lid Gasket
Ordering Specifications:
Product # 200TG-ENG Description lb. English Unit Tank Gauge up to 18 ft. 7.75 3.52
CARB CERTIFIED AST EQUIPMENT 61T-0208 2" Dia. x 8' Long Drop Tube 2.67 1.21
200TG-ENG40 English Unit Tank Gauge - 40 ft. 7.75 3.52 200TG-MET Metric Unit Tank Gauge up to 6 m 7.75 3.52
61T-0212 2" Dia. x 12' Long Drop Tube 4.00 1.81 61T-0216 2" Dia. x 16' Long Drop Tube 5.33 2.42
Underwriters Laboratory Listed UL Listing MH29367. Liquid level gauges which are intended to be used on above ground storage tanks and monitor the level of petroleum-based flammable or combustible fluids.
Enclosure: Polybutylene terephthalate Wire Grommet: Nylon w/ buna seal Float Switch: Closed cell buna float & stainless steel rod Pipe: Stainless steel Tank Adaptor: A luminum hardcoat anodized
Features
uU p to four alarm signals (444TA) can be used for high or low liquid level sensing, interstitial monitoring, and/or other signals in one to 4 separate tanks. u Self-Powered lithium battery with a 10-year shelf life for long service life. uA udible Alarm sounds a 90-decibel alarm at 4 feet away. u Visual Notifications red alarm light will flash during use for notification to the user. Low battery light indicates when battery needs replaced. u Corrosion-Resistant Construction petroleum and environmental resistant housing and all stainless steel pipe fitting ensure a long product life. u Product /Alarm Identification Label located on top of the alarm for quick and easy identification, allowing you to correspond alarms to signals. Label has a protective covering.
444TA
The OPW AST remote Four Signal Tank Alarm is designed to sense up to four different liquid levels or other signals using just one device. The OPW 144TA Tank Alarm is designed for liquid level sensing.
Alarm Technical Information: Hazardous Location Approval: Class I, Groups C & D Maximum Voltage: 7.2 Volts Maximum Current: 8 ma. per input (32 ma. total) Maximum Internal Capacitance: 23 uF Maximum Internal Inductance: 33 mH Maximum Ambient Temperature Rating: 60 C Maximum Surface Temperature Classification: T4 Surface Code Wiring limitations: 1000 foot maximum between the 144TA/444TA unit and any remote switch for each channel of the alarm. This assumes that maximum capacitance for any input is 60 nanoFarads and that the maximum inductance is 0.2 milliHenry per input (UL-913 A7.3) Note: This device is designed to work independently and should not be wired in parallel with another device, except as defined in the following instructions. Requirements for devices wired to the 144TA/444TA: Attached wiring and devices must be classed Intrinsically Safe No voltage or current source Maximum capacitance: 60 nanoFarads (.06 uF) per input Maximum inductance: 200 microHenrys (.2 mH) per input Float Switch Technical Information: Minimum liquid specific gravity: 0.45. Stem material: Stainless steel. Float Material: Closed Cell Buna-N (UL Approved) for gasoline services. Max Pressure: 150 psi @ 70 F. Thread 1/8" NPT. *NOTE: When replacing the battery for the 144TA-0100, open the alarm box and locate the OPW number on the black battery module. If the number reads C05346 then use the replacement part 15615M. If the number reads 144TA-0100 then use the replacement part 202891.
uI ntrinsically Safe complies with ANSI/ UL913 for Class 1, Division 1& 2 for Groups C&Dhazardous locations. uC old Weather Resistant all components are safe for temperatures down to -40F operation (and up to 120 F). u Long Life Lithium Battery selfpowered by a lithium battery which includes a 10-year shelf life to ensure peace of mind for the owner. uE asy Installation requires no calibration and installs easily into a 1" tank bung. May be assembled remotely or directly on top of tank.
TGTA-0400 4" Tank Bung Combo Fitting Note: Drop Tube must be used with TGTA-0400.
Ordering Specifications:
Product # 444TA-0100* 44TA-LLFS* 144TA-0100 TGTA-0400 Description Four Signal Tank Alarm, does not include Float Switch 36" Liquid-Level Float Switch Sub-Assembly Single Channel Liquid Level Tank Alarm, does not include Float Switch 4" Tank Bung Gauge and Alarm Combo Fitting (OPW 61T required for use) lb. 4 0 4 10 kg 1.8 0.0 1.8 4.5
The OPW 144TA Requires the OPW 44TA-LLFS, the OPW 44TA-LLFS must be purchased as a separate item.
Replacement Parts:
Part # Description 44TA-LLFS Liquid-Level Float Switch ASSY H15412M Wire Fitting H15411M Float Switch Items to Convert to a Low Level Alarm: 202430 1/8" SST Nipple C05295M SST Tube Battery Module H15937M 444TA-0100 See Note 144TA-0100*
444TA Dimensions:
A B C in. 5 1/32 5 1/32 4 3/16 in. 5 132 5132 3 4316 11516 35 11516 1 cm 12.8 12.8 10.6 cm 12.8 12.8 7.6 10.6 4.9 88.9 4.9 2.5
144TA Dimensions:
A B C D E F G H
Conforms to ANSI / UL STD 913 Certified to CAN / CSA STD C22.2 No. 157-92 Florida EQ-610 CARB Certified 444TA and 144TA Instruction Sheet Order Number: 200655
34
Materials
OPW 444TA AST Four Signal Tank Alarm and OPW 144TA AST LiquidLevelTankAlarm
Materials
Body: Cast aluminum Cap: Cast aluminum Seals: Nitrile Latch: Duratuff
Cast Aluminum
Ordering Specifications
Grommet Riser Thread Product # 62M-0375 Body Alum. Cap Alum. in.
3
7" 178mm lbs. 1.3 kg .59 1" 25mm 4 29/32" 124mm 4" NPT 51/2" 140mm 2 7/8" 73mm
mm
9.5
in. 4
mm 102
/8
/2
13
102
1.3
.59
Accepts .170" - .470" diameter wire Viton seals available upon request.
OPW 53 Bushings
OPW 53 Bushings are general-purpose bushings for use on tank vent lines, fill lines, suction lines or other lines where it is necessary or desirable to bush up or bush down.
Materials
Bushing: Iron
53
Ordering Specifications
Model # 53-0012 53-0020 53-0034 53-0036 53-0038 Threads (MNPT x FNPT) 2" x 11/2" (51 x 38 mm) 3" x 2" (76 x 51mm) 4" x 11/2" (102 x 38 mm) 4" x 2" (102 x 51mm) 4" x 3" (102 x 76 mm) lbs. .9 1.9 2.5 2.5 3.4 kg .4 .9 1.1 1.1 1.5
35
Body: Aluminum
An OPW FSA-400 Threaded Riser Face Seal Adaptor provides a flat, true sealing
FSA-400
surface on threaded pipes where a gasket seal exists per EVR requirements. The FSA-400 is installed on the fill pipe riser below the spill container to provide
Ordering Specifications
CARB APPROVED AST EQUIPMENT Product # FSA-400 FSA-400-S Description 4" Face Seal Adaptor 4" Short Face Seal Adaptor for Cast Iron Base Only
a true sealing surface for the drop tube flange on the overfill prevention valves. The FSA-400 is also required on tank gauging risers and optional on vapor risers and rotatable adaptors.
Materials
Body: Steel
Gauging Port.
Ordering Specifications
CARB APPROVED AST EQUIPMENT Product # 204247 Description Dedicated Gauging Port
36
Materials
Materials
Body: Clear anodized aluminum Bonnet: Powder-coated aluminum Cap: Powder-coated aluminum Spring: Stainless steel Hard-coated aluminum Poppet: Screw: Hard-coated aluminum Poppet Seal: Nitrile
199ASV
Features
u Factory-Adjusted Hydrostatic Head Pressure Settings allow for quick, safe and easy installation on above ground tanks. u Internal Pressure Relief Valve helps protect piping and fittings from damage due to thermal expansion. Set to operate between 20 to 40PSI (1.3 to 2.7 bar). u Aluminum Bodies compatible with gasoline, diesel, kerosene, ethanol, methanol, fuel oil and jet fuels. u Temperature Rating -20F - 120F (29C - 49C)
Valve Rating ft of gasoline S.G. = 0.7 Approximate Cracking Pressure PSI ft. H2O in. H2O in. Hg ft. Gas ft. Diesel 0-5 1.88 4.33 51.96 3.85 6.2 5.35 10.47 15.95 21.07 199ASV-1200 199ASV-2200 199ASV-3200 2 2 2 51 51 51 2.0 2.0 2.0 .907 .907 .907 0'-5' 5'-10' 10'-15'
Ordering Specifications
Hydrostatic Head Pressure* Product # 199ASV-1075 199ASV-2075 199ASV-3075 in.
3
mm 19 19 19
(Dimension A)
/4 /4 /4
1 1 1
25 25 25
38 38 38
5-10 3.68 8.48 101.76 7.53 12.12 10-15 5.6 12.92 155.04 11.47 18.51 15-20 7.4 17.07 204.84 15.16 24.4
*Note: S ome suction pumps may not have enough horsepower to open valve properly.
199ASV Anti-Siphon Valve
8 3/32" model for 1 1/2" and 2" (20.55cm model for 3.81cm and 5.08cm) 6 1/2" model for 3/4" and 1" (16.51cm model for 1.90cm and 2.54cm)
Top of Tank
Body: Aluminum Diaphragm: Viton Seals & Disc: Viton Springs: Stainless steel Rider Rings: Teflon Disc Holder: Nylon Core Guide: Acetal, delrin Core & Plugnut: Stainless steel
821-0150AC 1-1/2"
821-0075AC 3/4"
Features
The OPW 821 Solenoid Valve is designed to prevent accidental siphoning of above ground storage tanks if a leak or break occurs in the fuel supply line. The 821 valve is a two-way, normally closed diaphragm valve that opens when energized to allow fuel to flow to the pump or dispenser. Available in female NPT threads.
u Aluminum Body - compatible with gasoline, diesel, kerosene, low grades ethanol/methanol, fuel oil and jet fuels. uS trainer - strainer with 100-mesh screen is recommended at the inlet. u Mount - vertical. u Explosion Proof Shell & Water-Tight
821-0100AC 1"
uS tandard Operation - 120/60 volts AC. uT hermal Expansion u Power Draw - 20 Watts @ 60 Hz.
A
Ordering Specifications
Operating Pressure NPT Size General *CV Fluid Differential (PSI) Product # 821-0075AC 821-0100AC 821-0150AC 821-0200AC in.
3
Operating Pressure Differential (BAR) Min. 0 0 0 0 Max. 3.4 1.7 1.7 1.7 Weight lbs. kg Mounting Position Any Position
Max. 50 25 25 25
2.75 1.25
1 1 2
1
5.25 2.38 Upright &Vertical 7.25 3.29 Upright &Vertical 7.25 3.29 Upright &Vertical
Dimensions
A Product # 821-0075AC 821-0100AC 821-0150AC 821-0200AC in. 3.31 5.00 5.00 6.09 mm 84 127 127 155 in. 3.64 5.59 5.59 5.94 B mm 92 142 142 151 in. 4.46 6.84 6.84 7.47 C mm 113 174 174 190 in. 2.33 5.38 5.38 6.31 D mm 59 137 137 160 To Dispenser
OPW 82RV
The 82RV is designed to give thermal pressure relief to our 821 Series Solenoid Valve line. Made of all stainless steel construction with a Viton seal, it is suitable for all petroleum products. The 82RV is precision set at the factory at 25 PSI (1.7 bar), and is field adjustable from 5 to 30 psi (.34 to 2 bar).
Weight Operating Pressure 25 psi, Stainless Steel Construction lbs. .25 kg .113
mm 19
82RV-2505 Series Pressure Relief Valve Instruction Sheet Order Number: 200517
Materials
821-0200AC 2"
Materials
Body: Brass Ball: Hard chrome plated Seal: Teflon
21BV
Features
u Pressure rated to 600 psig (41 bar) WOG u Blowout-proof stem u Chrome-plated brass ball u Secondary O-ring stem seal u PTFE seats, thrust bearing and stem packing
/2 /4
1 1 /2
1
2 2 3
Body and Cap: Ductile iron Packing Nut and Stem: Stainless steel Disc: Viton Stem Seat: Viton Seat Ring: Brass Cap and Packing Nut Seals: Viton
(Valve Shown in Open Position)
Features
u 178S Ductile Iron Construction valve is manufactured from a ferrous metal to resist fracturing from high temperatures. uF ull-Bore Inside Diameter for Superior Flow Rates maximizes flow rates in the fuel supply lines. uP rotected Main Poppet Disc main poppet seal is held out of the main flow stream and protected from damage due to dirt or debris in the fuel. u Compensator Ring on Main Poppet Carrier ensures full seating of the main poppet for a tight seal. Viton Main Disc and Stem Seat u compatible with gasoline, diesel, kerosene, ethanol, methanol, MTBE, fuel oil, mogas, motor oil and various other blends of fuel. uR ated At Normal Pressure Limit of 125 psi (8.6 bar) (cold) u Non-Shock Pressure Limit of 200 psi (13.8 bar) u Temperature Limit 225 F
The OPW 178S Series External AST Shut-Off Valve is designed to shut off product flow from an above ground storage tank, bulk loading rack or any place in the fuel supply line in the event of a fire. The 178S installs in-line on fuel supply piping. A fusible link attached to a spring-operated lever holds the poppet normally open. In the event of a fire, the fusible link melts at 160 F, allowing the spring-actuated poppet to shut off the flow of product in the fuel supply line. The 178S is available in 2" female NPT connections.
A 1 B
3 4 5 6 C 7 8 9
2 Description
Spring O-ring (Viton) Packing Nut O-ring (Viton) Fusible Link Sub-Assy. Pin Stem Set Screw Lever Washer Disc Nut Disc (Viton) Disc Holder Compensating Ring Carrier Cap Retaining Ring
16
Ordering Specifications
Product # 178S-6130 in. 2 mm 51 lbs. 5.35 kg 2.43
Part No. H05973M H12070M H7635RB H10445M H01344M H01505RB C01533RB H07644M H07642ZA H03295M H04035M H12071R H10004A H11293M C03144M H11547DI H10003M
10 11 12 13
17
13 14
Dimensions
in. A B C 5 / 32
17
mm 140 78 62
31/16 31/16
For more information contact OPW Customer Service at 1-800-422-2525; International call 1-513-870-3315.
40
Materials
Materials
Body: Bronze Seat Ring: Brass Disc: Viton Cap: Bronze
Features
u Viton Main Disc - compatible with gasoline, diesel, kerosene, ethanol, methanol, MTBE, fuel oil, mogas, motor oil and various other blends of fuel. uF ull-Bore Inside Diameter for Superior Flow Rates maximizes flow rates in the fuel supply lines. uE asy Service Entry threaded cap assembly allows removal, replacement or servicing of the carrier, disc or disc holder. u Rated Normal Pressure Limit: 125 psi (8.6 bar) u Cold Non-Shock Pressure Limit: 200 psi. (13.8 bar) u Temperature Limit: 225 F
Ordering Specifications
Product # 175-0044 175B-1544 1175-0050 in. 2 2 3 mm 51 51 76 lbs. 4.7 4.6 16.8 kg 2.14 2.10 7.60
Replacement Parts
OPW 175, 175B, 1175 Key 1 (175,175B) 1 (1175) 2 (175,175B) 2 (1175) 3 (175,175B) 3 (1175) Part # H00409RB H06797RB H00404RB H06798RB H00642B H06800B H12071R H06799 H04035M H07488A H07495A H07610RB H06796B H05792M H03295M H04250M Description Pin Stem Plug Plug Cap Cap Disc Disc Sub-Assy. Disc Nut Disc Holder Disc Holder Carrier Carrier Retaining Ring Washer Lock Nut
Dimensions
in. A B C 71/2 7 /16
3
6 (175) mm 191 183 66 6 (175B) 7 (175, 175B) 7 (1175) 8 (175, 175B) 9 (175, 175B) 10 (1175)
219/32
41
DISPENSING HARDWARE
OPW nozzles are found in more locations worldwide than any other brand. From our complete line of conventional automatic fueling nozzles, swivels, breakaways, and island accessories to our wide range of rugged manual nozzles, OPW sets the industry standard in performance, durability and reliability. OPW offers a complete range of Stage II vapor recovery nozzles, from our industry-changing vacuum-assist vapor recovery nozzles and reliable balance technology to the 21Gv Series ORVR nozzle.
42
DISPENSING PRODUCTS
Materials
Housing: Impact-resistant plastic Cable: Black polyester Post: Aluminum (2"x 2")
Sliding Bracket Top and Pulley Assembly Post 2" x 2"
Retractor Foot
Features
u E asy to Use counterweights are precisely matched to each hose configuration to ensure that a minimal pulling force is needed throughout hose extension. u Easy to Maintain the 100 has just two moving parts, ensuring a long service life with a minimum of maintenance. u Multiple Hose Configurations the 100 is available in a multitude of configurations to meet virtually any conventional or vapor recovery hose/nozzle configuration. Models are also available for air and water hose applications to keep hoses clear of vehicles when not in use.
Ordering Specifications
Conventional and Vapor Recovery Applications
Clamp Fits Model Number* 6100-4000 6100-5000 6100-6000 6100-7000 Hose Configuration Conventional Conventional Conventional Conventional Conventional Conventional Hose Length ft. 12-14' 15-18' 12-14' 15-20' 12-14' 15-20' 11-13' 11-13' Hose O.D. mm 35 35 26 26 25 25
5 5
Height in.
Weight kg 15.0 17.2 13.6 14.1 13.2 13.6 15.0 11.8 14.1
mm 25 25
cm lbs.
4.6-6.1 1 32"
1
100 Series Counterweight Hose Retractor Instruction Sheet Order Number: H15852PA
6100-8000 6100-9000
1" 1"
8" 8"
16 16
79" 201 29 92" 234 30 79" 201 33 79" 201 26 79" 201 31
(Hose Clamp Not Included) (Hose Clamp Not Included) (Hose Clamp Not Included)
*Add a P to the end of model number for black epoxy coated mounting post. EXAMPLE: 6100-4000P
NOTE: See OPWs Website at www.opwglobal.com for product instruction sheets, trouble shooting guides, how-to-use guide and to view the Dos & Donts at the Gas Pump video.
43
Features
u Easy to Use the spring-loaded reel and stretch-resistant cable provide smooth and steady tension throughout hose extension and return. Easy to maintain the removable u sideplate provides full access to the mechanism for easy tension adjustment and unit maintenance. A convenient safety thumb screw is provided to lock the reel in place during tension adjustment. u Field Adjustable for Various Hose, Nozzle, Swivel, Breakaway Combinations no need for upgrading components if a breakaway or swivel is added to the hose assembly. Simply change the tension setting on the spring-loaded hose reel. u Multiple Mounting Options the POMECO 102 retractor housing is tapped on the top for bolting to overhead crossbars, and on the side for mounting to vertical posts. The 102 is available as a retractor kit (including post, retractor and mounting hardware) or as separate components. Models are also available for aboveground storage tank (AST) applications. AST models include a 44" (112 cm) post with a freestanding base.
POMECO 102 Spring Balance Single Hose Retractors keep excess hose off the ground and out of the way, prolonging hose life and reducing potential hazards. The POMECO 102 is a California Air Resources Board (CARB) certified Stage II component for use with single and dual hose dispensers as per Executive Order G-70-52-AM.
Post Mounted
102 Spring Balance Hose Retractor Instruction Sheet Order Number: H15853PA
NOTE: See OPWs Website at www.opwglobal.com for product instruction sheets, trouble shooting guides, how-to-use guide and to view the Dos & Donts at the Gas Pump video.
44
Materials
Ordering Specifications
Vertical Retractor Kits (Box, Post, Bracket, Foot & Hardware)
Model Number 6102-1039P 6102-1078P 6102-AST Clamp Fits Mounting Method in. 39" Retractor/Post Kit 78" Retractor/Post Kit AST Hose O.D. mm in. Hose I.D. mm lbs. 12 14 9 Weight kg 5.4 6.4 4.1
(Hose Clamp Not Included) (Hose Clamp Not Included) (Hose Clamp Not Included)
Ordering Specifications
Separate Retractor Components (Box Only)
Model Number 6102-1000 6102-4000 6102-6000 6102-8000 Clamp Fits Mounting Method in. Overhead Crossbar/Vertical Post Overhead Crossbar/Vertical Post Overhead Crossbar Overhead Crossbar 138" 1132" 1" Hose O.D. mm in. Hose I.D. Weight mm lbs. 7 25 16 or 19 16 7 7 7 kg 3.2 3.2 3.2 3.2
8 "
* POMECO recommends using CO5238M, CO5261M or P100-3F/P100-44/P100-2AST for use with 102 Series retractors. Other size tubes and clamps available upon request.
Ordering Specifications
Hose Clamps
Model Number PB-1396 PB-1394 PB-1375 PB-1373 PB-1344 PB-1340
Other sizes available upon request
Hose Clamp Size Standard 138" O.D. Hose (1" I.D.) Standard 118" O.D. Hose (34" I.D.) Standard 1132" O.D.Hose (58" or 34" I.D.) Standard 1" O.D. Hose (58" I.D.) Balanced Coaxial, Goodyear Premier Balanced Coaxial, Dayco Petroflex
45
D esigned specifically for AST dispenser applications O ffers a way to contain leaks from AST dispensers during use and filter change outs P rovides a raised platform for AST pipe runs into the dispenser to avoid burying underground piping Flexible by design interchangeable tops for a variety of dispenser pans
Stabilizer Bar
TOTANK
For use with Dispenser Model No. Gasboy 9800 Series (28-1/4" Frame) Gilbarco Advantage Model Dresser/Wayne Select Model Global Century Model Pump Porch
WARNING: Dispenser and pedestal must be surrounded by protective bumper curbing. Shear Valve is a fire valve only when installed in the pump pedestal.
PPT-1630
DP-1630
PP-2136
46
47
OPW is the world leader in commercial and industrial protective curbing products. The company designs, engineers and manufactures island forms, curb fascia, pipe and bumper guards to meet virtually any protective curbing application. Designed to protect gasoline dispensers, electronic equipment, kiosks, bank teller and ATM equipment, as well as to restrict or route material handling equipment in warehouses, OPW Island Forms and Protective Curbing streamline traffic flows in toll booths and quick-serve restaurants and various other commercial traffic management applications.
48
Revised 02/01/2011
Kerosene/ Fuel Oil
Above Ground Storage Tank Products 523V Series 623V Series 61VSA-1020-EVR 1611AVB-1625 1711T-7085-EVR 1711LPC-0300 301, 201 & 202 Series 200TG Series 444TA Series 821 Series 21BV SS 331 / 332 Series 61 STOP 61 STOP - A or M Version
UL - UL listed
B5
B20
X X X X X X X X X X X X X X
X X X X X X
X X X X X X X
* * * * * *
X X X X X X X X X X X
Vapor Swivel Adaptor Vapor Adaptor Vapor Cap Low Profile Vapor Cap
Emergency Vents AST Mechanical Gauge Tank Alarms Solenoid Valves Full Port Stainless Steel Ball Valves AST Spill Containers AST Overfill Valve AST Overfill Valve Anodized
ULC - UL Canada
X X
X X X X
* *
X X X X
X X
X X
X - Compatible
* Pending Approval
The ETL Listed Mark and C-ETL Listed Mark are accepted throughout the United States and Canada when denoting compliance with nationally recognized standards such as ANSI, IEC, UL, and CSA.
49
* Products certified to California 2001 Standards will have an OPW registration card enclosed/attached to the product.
OPWs exclusive obligation under this limited warranty is, at its option, to repair, replace or issue credit (in an amount not to exceed the list price for any defective product) for future orders for any product that may prove defective within the applicable warranty period (repairs or replacements are subject to prorated warranty coverage for remainder of the original warranty period). Complete and proper warranty claim documentation and proof of purchase required. All warranty claims must be made in writing and delivered during the applicable warranty period to OPW at P.O. Box 405003, Cincinnati, Ohio 45240. Attention: Customer Service Manager. No products may be returned to OPW without its prior written authority. This limited warranty shall not apply to any FlexWorks or VAPORSAVER product unless it is installed by an OPW attested installer. This limited warranty also shall not apply to any FlexWorks, VAPORSAVER or other OPW product: unless all required site and warranty registration forms are completed and received by OPW within 60 days of installation; unless all piping connections are installed with a nationally-recognized or state-approved leak detection device in each tank and dispenser sump (which are not for storage and from which all discharge hydrocarbons must be removed, and the systems completely cleaned, within 24 hours); unless testable sumps utilize FlexWorks pipe and access fittings; unless a sump inspection log or an EPA recommended/required checklist is maintained and the results are furnished to OPW upon request; and unless OPW is notified within 24 hours of any known or suspected product failure and is provided with unrestricted access to the product and the site. This limited warranty also shall not apply to any product which has been altered in any way, which has been repaired by anyone other than a service representative authorized by OPW, or when failure or defect is due to: improper installation or maintenance (including, without limitation, failure to follow FlexWorks Quick Reference Manual Installation Guide and all product warning labels); abuse or misuse; violation of health or safety requirements; use of another manufacturers, or otherwise unauthorized, substances or components; soil or other surface or subsurface conditions; or fire, flood, storm, lightning, earthquake, accident or any other conditions, events or circumstances beyond OPWs control. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND ALL OTHER WARRANTIES INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXCLUDED. OPW shall have no other liability whatsoever, whether based on breach of contract, negligence, gross negligence, strict liability or any other claim, including, without limitation, for special, incidental, consequential or exemplary damages or for the cost of labor, freight, excavation, clean-up, downtime, removal, reinstallation, loss of profit, or any other cost or charges. No person or entity is authorized to assume on behalf of OPW any liability beyond this limited warranty. This limited warranty is not assignable.
50
GlobalOperations
www.opwglobal.com
Corporate Headquarters 9393 Princeton-Glendale Road Hamilton, Ohio, USA 45011 Tel: (800)-422-2525 Fax: (800)-421-3297 Intl Tel: (513) 870-3315 Intl Fax: (513) 870-3157 [email protected] www.opwglobal.com
Brazil Rod. Romildo Prado, Km. 13,5 Bairro de Itapema Caixa Postal 170 CEP 13255-750 Itatiba - SP- Brasil Tel: 55 11 4894-7700 Fax: 55 11 4894-7701 www.opwbrasil.com.br
Czech Republic DOVER CR spol. s r.o.(OPW) Prumyslova 4 431 51 Klasterec nad Ohri Czech Republic Tel: +420 474 624 025 Fax: +420 474 628 271 [email protected]
OPW Fuel Management Systems 6900 Santa Fe Dr. Hodgkins, Illinois, USA 60525 Tel: 708 485-4200 Fax: 708 485-7137 [email protected] www.opwglobal.com
OPW Mexico Centro de Servicio OPW-Mxico Homero 136 Int. 403 Col. Chapultepec Morales Mxico DF CP 11570 Delegacin Miguel Hidalgo Tel: 52 55 5254-5672 Fax: 52 55 5254-1913 [email protected]
Dover India Pvt Ltd. OPW Fueling Components Div. A-93 , Wagle Industrial Estate Thane 400 604 Maharashtra, India Tel: 91 22 6710 0812,13,14 Fax: 91 22 6710 0815 [email protected]
OPW Fueling Containment Systems 3250 US Highway 70 Business West Smithfield, NC 27577-6954 Telephone: (919) 934-2786 Fax: (919) 359-3687 Customer Service: 1(800) 422-2525 Customer Service Fax: 1(800) 421-3297 www.opwglobal.com
Poland/Petro Vend of Poland, Inc. 32-086 Wegrzce 101 (Krakw) Poland Tel: ++ 48 12 4106600 Fax:++ 48 12 4106690 [email protected]
OPW Fueling Components (Suzhou) Co. Ltd. No.668, Fengting Road Loujiang Industrial Zone E2 Suzhou Industrial Park Suzhou, P.R.C. 215122 Tel: 86-(0)512-6274-5328 Fax: 86-(0)512-6274-5338 [email protected] www.opw-fc.com.cn
2011, OPW Fueling Components 2011 Delaware Capital Formation, Inc. All Rights Reserved. DOVER and the DOVER logo are registered trademarks of Delaware Capital Formation, Inc., a wholly-owned subsidiary of Dover Corporation.