NXP & NXC
NXP & NXC
NXP & NXC
The quality and reliability of a machine or process is in most cases the result of the precise, dynamic control of AC motors. The Vacon NXP has been designed to provide the best possible control under all circumstances, ensuring high operational quality and availability for the entire lifetime of a system. A forerunner in designing and manufacturing AC drives, Vacon has developed innovative solutions and leading-edge technology for demanding applications and high power ranges. By bringing these solutions to customers, the Vacon NXP opens up new opportunities and helps them create the best and highly innovative products and achieve the most challenging targets.
Features
Full power and voltage range High number of options Wide set of applications adapts the Vacon NXP to virtually any need Controls induction and permanent magnet motors Dynamic open and closed loop vector control Complete range of communications and I/O options Fast drive-to-drive communication
Removable display
fr4 fr9
fr4
2
fr5
fr6
fr7
fr8
fr9
outstanding flexibility
The Vacon NXP offers, in addition to its control characteristics, a wide choice of products and cabinets for the varying needs in the high-power range.
Three models are available to meet various customer needs as follows: Vacon NXP IP21/IP54 wall-mounted or standalone drives for installation wherever there is space available Vacon NXP high-power IP00 drive modules for installation in the customer's cabinet Vacon NXC robust cabinet drive with maximum exibility and a wide range of options
Loadability Motor shaft power 230 V supply Maximum current I S 4.8 7.4 9.6 13.2 15.6 22 25 35 50 62 96 122 150 176 210 280 336 349 444 10% overload P (kW) 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 22 22 30 37 45 55 75 90 50% overload P (kW) 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 22 22 30 37 45 55 75 Frame size FR4 FR4 FR4 FR4 FR4 FR4 FR5 FR5 FR5 FR6 FR6 FR7 FR7 FR7 FR8 FR8 FR8 FR9 FR9 Dimensions and weight W*H*D (mm)/ kg 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 144*391*214/ 8.1 144*391*214/ 8.1 144*391*214/ 8.1 195*519*237/ 18.5 195*519*237/ 18.5 237*591*257/ 35 237*591*257/ 35 237*591*257/ 35 291*758*344 / 58 291*758*344 / 58 291*758*344 / 58 480*1150*362/ 146 480*1150*362/ 146 High (+50C) Rated continuous current I H (A) 2.4 3.7 4.8 6.6 7.8 11 12.5 17.5 25 31 48 61 75 88 105 140 170 205 245 50% overload current (A) 3.6 5.6 7.2 9.9 11.7 16.5 18.8 26.3 37.5 46.5 72 92 113 132 158 210 255 308 368
Low (+40C) AC drive type Rated continuous current I L (A) 3.7 4.8 6.6 7.8 11 12.5 17.5 25 31 48 61 75 88 114 140 170 205 261 300 10% overload current (A) 4.1 5.3 7.3 8.6 12.1 13.8 19.3 27.5 34.1 52.8 67.1 83 97 125 154 187 226 287 330
NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP
0003 0004 0007 0008 0011 0012 0017 0025 0031 0048 0061 0075 0088 0114 0140 0170 0205 0261 0300
2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 1 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSS 2 A 2 H 0 SSF 2 A 2 H 0 SSF
Loadability Motor shaft power 400 V supply Maximum current I S 4.4 6.2 8.6 10.8 14 18 24 32 46 62 76 92 122 144 174 210 280 336 349 444 10% overload P (kW) 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 50% overload P (kW) 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 Frame size Dimensions and weight W*H*D (mm)/ kg 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 128*292*190/ 5 144*391*214/ 8.1 144*391*214/ 8.1 144*391*214/ 8.1 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 237*591*257/ 35 237*591*257/ 35 237*591*257/ 35 291*758*344 / 58 291*758*344 / 58 291*758*344 / 58 480*1150*362/ 146 480*1150*362/ 146 High (+50C) Rated continuous current I H (A) 2.2 3.3 4.3 5.6 7.6 9 12 16 23 31 38 46 61 72 87 105 140 170 205 245 50% overload current (A) 3.3 5 6.5 8.4 11.4 13.5 18 24 35 47 57 69 92 108 131 158 210 255 308 368
Low (+40C) AC drive type Rated continuous current I L (A) 3.3 4.3 5.6 7.6 9 12 16 23 31 38 46 61 72 87 105 140 170 205 261 300 10% overload current (A) 3.6 4.7 6.2 8.4 9.9 13.2 17.6 25.3 34 42 51 67 79 96 116 154 187 226 287 330
NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP
0003 0004 0005 0007 0009 0012 0016 0022 0031 0038 0045 0061 0072 0087 0105 0140 0168 0205
5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 1 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS 5 A 2 H 0 SSS
FR4 FR4 FR4 FR4 FR4 FR4 FR5 FR5 FR5 FR6 FR6 FR6 FR7 FR7 FR7 FR8 FR8 FR8 FR9 FR9
Loadability Motor shaft power 690 V supply Maximum current I S 6.4 9.0 11 15 20 27 36 44 54 68 82 104 124 160 200 213 245 289 10% overload P (kW) 3 4 5.5 7.5 11 15 18.5 22 30 37.5 45 55 75 90 110 132 160 200 50% overload P (kW) 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37.5 45 55 75 90 110 132 160 Frame size Dimensions and weight W*H*D (mm)/ kg 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 195*519*237/ 18.5 237*591*257/ 35 237*591*257/ 35 291*758*344 / 58 291*758*344 / 58 291*758*344 / 58 480*1150*362/ 146 480*1150*362/ 146 480*1150*362/ 146 480*1150*362/ 146 High (+50C) Rated continuous current I H (A) 3.2 4.5 5.5 7.5 10 13.5 18 22 27 34 41 52 62 80 100 125 144 170 50% overload current (A) 4.8 6.8 8.3 11.3 15 20.3 27 33 41 51 62 78 93 120 150 188 216 255
Low (+40C) AC drive type Rated continuous current I L (A) 4.5 5.5 7.5 10 13.5 18 22 27 34 41 52 62 80 100 125 144 170 208 10% overload current (A) 5 6.1 8.3 11 14.9 19.8 24.2 29.7 37 45 57 68 88 110 138 158 187 229
NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP NXP
0004 0005 0007 0010 0013 0018 0022 0027 0034 0041 0052 0062 0080 0100 0125 0144 0170 0208
6 A 2 L 0 SSS 6 A 2 L 0SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSS 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF
FR6 FR6 FR6 FR6 FR6 FR6 FR6 FR6 FR6 FR7 FR7 FR8 FR8 FR8 FR9 FR9 FR9 FR9
Loadability Motor shaft power 400 V supply Maximum current I S 10% overload P (kW) 200 250 250 315 355 400 50% overload P (kW) 160 200 250 250 315 355 Frame size Dimensions and weight W*H*D (mm)/ kg 595*2020*602/ 340 595*2020*602/ 340 595*2020*602/ 340 794*2020*602/ 470 794*2020*602/ 470 794*2020*602/ 470 High (+40C) Rated continuous current I H (A) 300 385 460 520 590 650 50% overload current (A) 450 578 690 780 885 975
Low (+40C) AC drive type Rated continuous current I L (A) 385 460 520 590 650 730 10% overload current (A) 424 506 572 649 715 803
NXP 0385 5 A 2 L 0 SSA NXP 0460 5 A 2 L 0 SSA NXP 0520 5 A 2 L 0 SSA NXP 0590 5 A 2 L 0 SSA NXP 0650 5 A 2 L 0 SSA NXP 0730 5 A 2 L 0 SSA
Loadability Motor shaft power 690 V supply Maximum current I S 10% overload P (kW) 250 315 355 400 450 500 560 50% overload P (kW) 200 250 315 315 355 450 500 Frame size Dimensions and weight W*H*D (mm)/ kg 595*2020*602/ 340 595*2020*602/ 340 595*2020*602/ 340 595*2020*602/ 340 794*2020*602/ 400 794*2020*602/ 400 794*2020*602/ 470 High (+40C) Rated continuous current I H (A) 208 261 325 325 385 460 502 50% overload current (A) 312 392 488 488 578 690 753
Low (+40C) AC drive type Rated continuous current I L (A) 261 325 385 416 460 502 590 10% overload current (A) 287 358 424 458 506 552 649
NXP 0261 6 A 2 L 0 SSA NXP 0325 6 A 2 L 0 SSA NXP 0385 6 A 2 L 0 SSA NXP 0416 6 A 2 L 0 SSA # NXP 0460 6 A 2 L 0 SSA NXP 0502 6 A 2 L 0 SSA NXP 0590 6 A 2 L 0 SSA #
# max. ambient temperature of +35C
hardware configurations
FUNCTION IP21 IP54 (FR10 only) Integrated fuses Load switch EMC ltering L EMC ltering T Brake chopper (cabling top entry) AVAILABILITY Standard Optional Standard Optional Standard Optional Optional (H: +122 mm)
Loadability Motor shaft power 400 V supply Maximum current I S 10% overload P (kW) 200 250 250 315 355 400 450 500 560 50% overload P (kW) 160 200 250 250 315 355 400 450 500 Frame size Module W*H*D (mm)/ kg Chokes W*H*D (mm)/ kg High (+40C) Rated continuous current I H (A) 300 385 460 520 590 650 730 820 920 50% overload current (A) 450 578 690 780 885 975 1095 1230 1380
Low (+40C) AC drive type Rated continuous current I L (A) 385 460 520 590 650 730 820 920 1030 10% overload current (A) 424 506 572 649 715 803 902 1012 1133
NXP 0385 5 A 0 N 0 SSA NXP 0460 5 A 0 N 0 SSA NXP 0520 5 A 0 N 0 SSA NXP 0590 5 A 0 N 0 SSA NXP 0650 5 A 0 N 0 SSA NXP 0730 5 A 0 N 0 SSA NXP 0820 5 A 0 N 0 SSA NXP 0920 5 A 0 N 0 SSA NXP 1030 5 A 0 N 0 SSA
500*1165*506/ 120
350*383*262/ 84 1)
500*1165*506/ 120 497*399*244/ 115 1) 500*1165*506/ 120 497*399*244/ 115 1) 709*1206*506/ 210 709*1206*506/ 210 709*1206*506/ 210 2x(350*383*262/ 84) 2x(350*383*262/ 84) 2x(350*383*262/ 84)
2x(500*1165*506/ 120) 2x(497*399*244/ 115) 2x(500*1165*506/ 120) 2x(497*399*244/ 115) 2x(500*1165*506/ 120) 2x(497*399*244/ 115)
Loadability Motor shaft power 690 V supply Maximum current I S 10% overload P (kW) 250 315 355 400 450 500 560 630 710 800 50% overload P (kW) 200 250 315 315 355 450 500 560 630 630 Frame size Module W*H*D (mm)/ kg Chokes W*H*D (mm)/ kg High (+40C) Rated continuous current I H (A) 208 261 325 325 385 460 502 590 650 650 50% overload current (A) 312 392 488 488 578 690 753 885 975 975
Low (+40C) AC drive type Rated continuous current I L (A) 261 325 385 416 460 502
#
10% overload current (A) 287 358 424 458 506 552 649 715 825 902
NXP 0261 6 A 0 N 0 SSA NXP 0325 6 A 0 N 0 SSA NXP 0385 6 A 0 N 0 SSA NXP 0416 6 A 0 N 0 SSA # NXP 0460 6 A 0 N 0 SSA NXP 0502 6 A 0 N 0 SSA NXP 0590 6 A 0 N 0 SSA NXP 0650 6 A 0 N 0 SSA NXP 0750 6 A 0 N 0 SSA NXP 0820 6 A 0 N 0 SSA #
375 470 585 585 693 828 904 1062 1170 1170
FR10 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12
500*1165*506/ 120 354*319*230/ 53 1) 500*1165*506/ 120 350*383*262/ 84 1) 500*1165*506/ 120 350*383*262/ 84 1) 500*1165*506/ 120 350*383*262/ 84 1) 709*1206*506/ 210 497*399*244/ 115 2) 709*1206*506/ 210 497*399*244/ 115 2) 709*1206*506/ 210 2x(350*383*262/ 84) 2x(500*1165*506/ 120) 2x(350*383*262/ 84) 2x(500*1165*506/ 120) 2x(350*383*262/ 84) 2x(500*1165*506/ 120) 2x(350*383*262/ 84)
hardware configurations
FUNCTION Integrated control unit External control unit Integrated brake chopper 6-pulse supply 12-pulse supply EMC ltering N EMC ltering T AVAILABILITY Standard Optional Optional Standard Optional Standard Optional
Easy ordering The Vacon NXC contains the AC drive itself and optional items such as main switch, contactor, control options and output ltering in one compact unit which is easy to install and service. Ordering is made easy by integrating the Vacon NXC enclosure options into the typecode, to which they are appended with + codes.
User-friendly In the Vacon NXC, the control unit is mounted in a separate compartment at an easily accessible height together with all control options. Ample space around the power terminals allows easy installation and connection of power cables. Bottom plates and earthing clamps for 360-degree earthing of motor cable shields are provided as standard.
Well tested Vacon NXC drives are the result of more than 20 years of experience in enclosure design. It is a well tested and proven solution. The good thermal handling of the enclosure guarantees a long lifetime for the AC drive and trouble-free operation even in the most demanding environments. Approved EMC solutions ensure reliable operation of the converter without disturbing other electrical equipment.
Service-friendly The Vacon NXC enclosures are designed to fully utilize the new and innovative installation features of the high-power Vacon NXP. The Vacon NXP power units are mounted on rails which are extendable with a pull-out jig. The jig can be used for pulling the power unit out of the enclosure for service.
NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC
0261 0300 0385 0460 0520 0590 0650 0730 0820 0920 1030 1150 1300 1450 1770 2150
5 A 2 H 0 SSF 5 A 2 H 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF 5 A 2 L 0 SSF
349 444 540 693 828 936 1062 1170 1314 1476 1656 1854 2070 2340 2880 3492
FR9 FR9 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14
NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC
0125 0144 0170 0208 0261 0325 0385 0416 0460 0502 0590 0650 0750 0820 0920 1030 1180 1500 1900 2250
6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF# 6 A 2 L 0 SSF 6 A 2 L 0 SSF 6 A 2 L 0 SSF#
200 213 245 289 375 470 585 585 693 828 904 1062 1170 1170 1410 1755 1755 2340 2700 3335
FR9 FR9 FR9 FR9 FR10 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14 FR14
hardware configurations
6-pulse Enclosure EMC Brake chopper IP54 L T H 380-500 V IP21 FR9 S O (H: +130) S O FR10 S O (H: +130) S O FR11 S O (H: +130)* S O FR12 S O (H: +130) S O FR13 S O (H: +170) S O FR14 S O (H: +170) S O 500-690 V FR9 S O (H: +130) S O FR10 S O (H: +130) S O FR11 S O (H: +130)* S O FR12 S O (H: +130) S O FR13 S O (H: +170) S O FR14 S O (H: +170) S O O O O O
1 1
Cabling Top Bottom S S S S S S S S S S S S +CIT/+COT O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) +IFU O O O O O O O O +ILS O O O O O O O O -
Input device Fuses Load Sw. Sw.-fuse Contactor MCCB Cmn Mode +IFD O O O O S O O O O S +ICO O O O O O O O O +ICB O O O O O S O O O O O S +OCM O O O O O O O O O O O O
Output lters du/dt +ODU O (W: +400) O (W: +400) O (W: +400) O (W: +400) O S O (W: +400) O (W: +400) O (W: +400) O (W: +400) O S Sine wave +OSI O(W: +600) O(W: +600) O(W: +600-800) O(W: +1200) O(W: +800) O(W: +1600) O(W: +600) O(W: +600) O(W: +600) O(W: +1200) O(W: +800) O(W: +1600)
O O O O
1 1
S = Standard
10
O = Optional
1)
NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC
0385 0460 0520 0590 0650 0730 0820 0920 1030 1150 1300 1450 1770 2150
5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF 5 A 2 L 0 TSF
540 693 828 936 1062 1170 1314 1476 1656 1854 2070 2340 2880 3492
FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14
NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC NXC
0261 0325 0385 0416 0460 0502 0590 0650 0750 0820 0920 1030 1180 1500 1900 2250
6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF# 6 A 2 L 0 TSF 6 A 2 L 0 TSF 6 A 2 L 0 TSF#
375 470 585 585 693 828 904 1062 1170 1170 1410 1755 1755 2340 2700 3335
FR10 FR10 FR10 FR10 FR11 FR11 FR11 FR12 FR12 FR12 FR13 FR13 FR13 FR14 FR14 FR14
hardware configurations
12-pulse Enclosure L S S S S S EMC T H O O O O O Brake chopper IP54 380-500 V IP21 FR10 S O (H: +130) FR11 S O (H: +130)* FR12 S O (H: +130) FR13 S O (H: +170) FR14 S O (H: +170) 500-690 V FR10 S O (H: +130) FR11 S O (H: +130)* FR12 S O (H: +130) FR13 S O (H: +170) FR14 S O (H: +170) O O
1 1
Cabling Top Bottom S S S S S S S S S S +CIT/+COT O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +800) O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +800) +IFU O O O O O O +ILS O O O O -
Input device Fuses Load Sw. Sw.-fuse Contactor MCCB Cmn Mode +IFD O O O O +ICO O O O O +ICB O O O S S O O O S S +OCM O O O O O O O O O O
Output lters du/dt +ODU O (W: +400) O (W: +400) O (W: +400) O S O (W: +400) O (W: +400) O (W: +400) O S Sine wave +OSI O(W: +600) O(W: +600-800) O(W: +1200) O(W: +800) O(W: +1600) O(W: +600) O(W: +600) O(W: +1200) O(W: +800) O(W: +1600)
S O S O S O S O S O
O O
1 1
S = Standard
O = Optional
1)
11
The Vacon NXC regenerative and low-harmonic cabinet drives are a perfect choice for applications where low harmonics are required or where energy is fed back to the mains. Clean power saves costs The regenerative low-harmonic cabinet drive offers an excellent total solution to meet even the most demanding power quality requirements. The drive complies with the IEEE-519, G5/4 harmonic standards, when correctly installed. The low current THDi reduces supply currents and allows supply transformers, protection devices and power cables to be smaller. It brings savings for new and retrofit projects because there is no need to invest in expensive 12- or 18-pulse transformers when new or old existing 6-pulse transformers can be used. Regenerative functionality saves energy The regenerative function makes it possible to feed energy back to the mains in energy generation applications or to improve the efficiency of the system when the braking power can be fed back to the mains. An additional advantage is simplified installation work and space savings when no brake resistors are needed. Power factor control improves the supply The power factor of the active supply unit can be set in a wide range that makes it possible to minimize the required reactive power of the system. Main features Clean power with total current harmonics less than 5% Regenerative function brings savings Power factor control Compact solution with a wide range of standard options available makes it easy to configure the drive
12
Auxiliary equipment (A group) +AMF Motor fan control +AMH Motor heater feeder +AMB Mechanical brake control +ACH Cabinet heater +ACL Cabinet light +ACR Control relay +AAI Analog signal isolator +AAA Aux. contact (ctrl voltage) +AAC Aux. contact (input device) +AT3 Aux. voltage transformer 2500 VA +AT4 Aux. voltage transformer 4000 VA +ADS 230 VAC customer socket Control terminal options (T group) +TIO Basic I/O wired to external terminals +TID Basic I/O wired to external terminals + additional terminals
Door-mounted options (D group) +DLV Pilot light (control voltage on) +DLD Pilot light (DO1) +DLF Pilot light (FLT) +DLR Pilot light (RUN) +DEP Emergency stop push-button +DRP Reset push-button +DAM Analog meter (AO1) +DAR Potentiometer for reference +DCM Analog meter current trafo +DVM Analog voltage meter switch
Output lter options (O group) +OCM Common mode lters +ODU du/dt lter +OSI Sine wave lter Protection devices (P group) +PTR External thermistor relay +PES Emergency stop (cat 0) +PED Emergency stop (cat 1) +PAP Arc protection +PIF Insulation fault sensor
General options (G group) +G40 400 mm empty cabinet +G60 600 mm empty cabinet +G80 800 mm empty cabinet +GPL 100 mm base
Cabling options (C group) +CIT Input (mains) cabling from top +COT Output (motor) cabling from top
Direction of power 12-pulse rectier with choke Higher transformer and power cabling cost. Low current distortion on primary side of transformer.
Direction of power Active front-end with LCL lter Cost effective transformer and power cabling with very low current distortion. No oversizing of transformer needed.
13
NXC 0261 5 A 2 L 0 RSF NXC 0300 5 A 2 L 0 RSF NXC 0385 5 A 2 L 0 RSF NXC 0460 5 A 2 L 0 RSF NXC 0520 5 A 2 L 0 RSF NXC 0650 5 A 2 L 0 RSF NXC 0730 5 A 2 L 0 RSF NXC 0820 5 A 2 L 0 RSF NXC 0920 5 A 2 L 0 RSF NXC 1030 5 A 2 L 0 RSF NXC 1150 5 A 2 L 0 RSF NXC 1300 5 A 2 L 0 RSF NXC 1450 5 A 2 L 0 RSF NXC 1770 5 A 2 L 0 RSF NXC 2150 5 A 2 L 0 RSF NXC 2700 5 A 2 L 0 RSF
FI9 + FI9 FI9 + FI9 FI10 + FI10 FI10 + FI10 FI10 + FI10 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 FI13 + FI13 FI13 + FI13 FI13 + FI13 2xFI13 + FI14 2xFI13 + FI14 2xFI13 + FI14
NXC 0125 6 A 2 L 0 RSF NXC 0144 6 A 2 L 0 RSF NXC 0170 6 A 2 L 0 RSF NXC 0208 6 A 2 L 0 RSF# NXC 0261 6 A 2 L 0 RSF NXC 0325 6 A 2 L 0 RSF NXC 0385 6 A 2 L 0 RSF NXC 0416 6 A 2 L 0 RSF# NXC 0460 6 A 2 L 0 RSF NXC 0502 6 A 2 L 0 RSF NXC 0590 6 A 2 L 0 RSF NXC 0650 6 A 2 L 0 RSF NXC 0750 6 A 2 L 0 RSF NXC 0820 6 A 2 L 0 RSF# NXC 0920 6 A 2 L 0 RSF NXC 1030 6 A 2 L 0 RSF NXC 1180 6 A 2 L 0 RSF# NXC 1500 6 A 2 L 0 RSF NXC 1900 6 A 2 L 0 RSF NXC 2250 6 A 2 L 0 RSF#
FI9 + FI9 FI9 + FI9 FI9 + FI9 FI9 + FI9 FI10 + FI10 FI10 + FI10 FI10 + FI10 FI10 + FI10 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 2xFI10 + FI12 FI13 + FI13 FI13 + FI13 FI13 + FI13 2xFI13 + FI14 2xFI13 + FI14 2xFI13 + FI14
hardware configurations
Active supply unit 380-500 V FI9+FI9 FI10+FI10 2 x FI10+FI12 FI13+FI13 2 x FI13+FI14 525-690 V FI9+FI9 FI10+FI10 2 x FI10+FI12 FI13+FI13 2 x FI13+FI14 1) Contact factory S S S S S O (H: +130) O (H: +130) O (H: +130) O (H: +170) O (H: +170) S S S S S O O O O O 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) S S S S S O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) S S S S S O O O O O O (W:+400) O (W: +600) O (W:+400) O (W: +600) O (W:+400) O (W: +1200) O S O (W: +800) O (W: +1600) Enclosure IP21 S S S S S IP54 O (H: +130) O (H: +130) O (H: +130) O (H: +170) O (H: +170) L S S S S S EMC T O O O O O 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) 1) (W: +400) Brake chopper Cabling Bottom S S S S S Top +CIT/+COT O (W: +400) O (W: +400) O (W: +400) O (W: +400) O (W: +600) Input device Output lters Load Sw. & Cmn Mode du/dt Sinewave MCCB +OCM +ODU +OSI +ILS & +ICB S S S S S O O O O O O (W:+400) O (W: +600) O (W:+400) O (W: +600) O (W:+400) O (W: +1200) O S O (W: +800) O (W: +1600)
14
S = Standard
O = Optional
vacon drivesynch
The Vacon DriveSynch is a new, innovative control concept for running standard drives in parallel to control high-power AC motors. This concept suits high-power single or multiple winding motors typically above 1 MW.
High-power AC drives up to 5 MW can be built using standard drive components with the following benets:
System is modular and easy to extend High total power can be obtained combining smaller drives The redundancy of the system is higher than in a conventional drive because each unit can be run independently The small size of the individual drive makes it easy to maintain and service Identical individual units reduce the required amount of spare parts and costs No special skills are required for engineering, installation, commissioning and maintenance of high-power drives as they are made from standard low-power modules Du/dt filter at the output of each individual unit ensures load balancing Can also run multiple winding motors with a phase shift between the windings
15
option boards
Type Card slot
DI DO DI AI (mA/ V/V) AI (mA) isolated AO (mA/V) AO (mA) RO RO
I / O signal
+10Vref Therm +24V/ pt100 42-240 EXT +24V VAC input (10...24V) (RS422) DI/DO DI/DO DO (NO/ (NO)
A B C D E Basic I/O cards (OPT-A) OPT-A1 OPT-A2 OPT-A3 OPT-A4 OPT-A5 OPT-A7 OPT-A8 OPT-A9 OPT-AE OPT-AF OPT-AK OPT-B1 OPT-B2 OPT-B4 OPT-B5 OPT-B8 OPT-B9 OPT-BB OPT-BC OPT-BE OPT-C2 OPT-C3 OPT-C4 OPT-C5 OPT-C6 OPT-C7 OPT-C8 OPT-CF OPT-CG OPT-CI OPT-CJ OPT-D1 OPT-D2 OPT-D3 OPT-D6 OPT-D7 6 1
isolated NC)
1Vp-p
DI
Note
1 2 1 1
1 1
2 2 6 1 6 1 2 2 2 2 1 1 2 1 1 1 2 2
1 1 1
2 enc. input + 1 enc. output 1) 2.5 mm 2 terminals
1 1
2 2
Fieldbus cards (OPT-C) RS-485 (Multiprotocol) Probus DP LonWorks Probus DP (D9-type connector) CANopen (slave) DeviceNet RS-485 (Multiprotocol, D9-type connector) CAN / Euromap SELMA 2 protocol Modbus/TCP (Ethernet) BACNet, RS-485 System Bus adapter (2 x ber optic pairs) System Bus adapter (1 x ber optic pair) & CAN-bus adapter (galvanically decoupled) RS232 adapter card (galvanically decoupled), used mainly for application engineering to connect another keypad CAN-bus adapter (galvanically decoupled) Line voltage measurement 2) analogue signals galvanically isolated separately
Modbus, N2
Modbus, N2
NOTES: Allowed slots for the board are marked in blue. 1) analogue signals galvanically isolated as a group
16
OPT-A2
Default settings Reference voltage Frequency reference 010 V AI common (GND) Frequency reference 420 mA AI common (differential) Control supply (bidirectional) I/O Ground Start forward Start reverse External fault input Common for DIN1 - DIN3 (GND) Control supply (bidirectional) I/O Ground Multi-step speed select 1 Multi-step speed select 2 Fault reset Common for DIN4 - DIN6 (GND) Output frequency (020 mA) AO common (GND) READY, I < 50 mA, U < 48 VDC Many possibilities Many possibilities Many possibilities Floating Many possibilities 420 mA, 010 V PTC Many possibilities 230 VAC N +24 V GND Many possibilities Many possibilities Many possibilities Floating -10+10 V, 0/420 mA Differential 020mA, 0/-10 V10 V GND 230 VAC N Programmable +24 V GND Terminal 21 R01 22 R01 23 R01 24 R02 25 R02 26 R02 FAULT Many possibilities RUN Many possibilities Default settings Programmable
+10V AI1+ AI1AI2+ AI2+24V GND DIN1 DIN2 DIN3 CMA +24V GND DIN4 DIN5 DIN6 CMB AO1+ AO1DO1
OPT-A3 (alternative)
Terminal 21 R01 22 R01 23 R01 25 R02 26 R02 28 TI1+ 29 TI1Thermistor input FAULT Warning No response FAULT Many possibilities RUN Many possibilities Default settings Programmable
19 20
Default settings of OPT-A1, OPT-A2 and OPT-A3 for the Basic and Standard Applications.
10
+5V/+15V/+24V
17
first-class usability
Vacon PC tools can be downloaded from the Vacon website at http://www.vacon.com. They include: Vacon NCDrive for setting, copying, storing, printing, monitoring and controlling parameters Vacon NCLoad for updating software and uploading special software to the drive Vacon NC61131-3 Engineering is available for making tailor-made software. A license key and training are required. The text display with functions such as multi-monitoring, parameter copy, parameter backup and start-up wizard makes commissioning as easy as possible.
The Vacon NCDrive communicates with the drive via the following interfaces: RS-232 Ethernet TCP/IP CAN (fast multiple drive monitoring) CAN@Net (remote monitoring)
18
software modularity
The All-in-One application package has seven built-in software applications (=default settings and functionality of control inputs and outputs) which can be selected with one parameter. Which software application to use is asked by the Start-up Wizard at the rst power-up. With this single setting, the drive can be programmed for example for two external control places or pressure control with an integrated PID controller.
Flexible fieldbus process data connections Flexible speed and torque reference chains Adaptive speed controller Inertia compensation and oscillation damping features Fast drive-to-drive communication for master-follower applications Supports permanent magnet motors Integrated mechanical brake and motor fan control Emergency stop with separate ramp time
19
Lift Application
The Lift Application offers ready-made lift functions for easy commissioning and tuning of a lift. Induction and permanent magnet motor support Lift speed parameters in [Hz] and [m/s] Integrated lift brake control logic Lift evacuation feature. In case of power failure, the lift can be run to the next oor. In-built motor contactor control logic
Lift drive
Lift car
High-speed drive
Compressor
20
Safe disable
The function is intended for use where there is a need to ensure that the motor will not be driven by the drive, ie. for safe standstill, for example when there is a need to perform mechanical maintenance on a machine. In such installations the function may be used to replace mechanical power switches. The function is certied in accordance with EN954-1, Cat 3.
21
1ST ENVIRONMENT
3 2
4 5
2ND ENVIRONMENT
The product family standard EN61800-3 sets limits for both emissions and immunity to radio frequency disturbances. The environment has been divided into the rst and second environments, in practice, public and industrial networks, respectively. Radio Frequency Interference (RFI) lters are typically required to meet the EN61800-3 standard. These lters are integrated in the Vacon NXP as standard.
The 208240 V and 380500 V ranges of the Vacon NXP (FR4-FR9) meet the requirements of the rst and second environments (H level: EN61800-3(2004), category C2). No additional RFI lters or cabinets are required. The FR10-FR14 and the 500-690 V ranges of the Vacon NXP meet the requirements of the second environment (L-level: EN61800-3(2004), category C3). The units in the frame sizes FR4, FR5 and FR6 (with a voltage range from 380 to 500 V) are also available with extremely lowemission integrated EMC lters (C level: EN61800-3 (2004), category C1). This is sometimes required in very sensitive locations such as hospitals.
2
Residential Area
3
Commercial
4
Light Industry Area
5
Heavy Industry Marine
22
technical data
Mains connection Input voltage Uin Input frequency Connection to mains Motor connection Output voltage Continuous output current 208240 V; 380500 V; 500...690 V; 10%+10% NXC regenerative low-harmonic drive 525-690 V; -10%...+10% 4566 Hz Once per minute or less (normal case) 0Uin High overloadability: IH, ambient temperature max. +50C (FR10 + 40C) Low overloadability: IL , ambient temperature max. +40C Overloadability Max. starting current Output frequency Control characteristics Control performance High: 1.5 x IH (1 min/10 min), Low: 1.1 x IL (1 min/10 min) Is for 2 s every 20 s 0320 Hz; up to 7200 Hz with special software Open loop vector control (5-150% of base speed): speed control 0.5%, dynamic 0.3%sec, torque lin. <2%, torque rise time ~5 ms Closed loop vector control (entire speed range): speed control 0.01%, dynamic 0.2%sec, torque lin. <2%, torque rise time ~2 ms NX_2/ NX_5: Up to and including NX_0061: 116 kHz; Factory default 10 kHz From NX_0072: 110 kHz; Factory default 3.6 kHz 16 kHz; Factory default 1.5 kHz
Switching frequency
NX_6: Field weakening point Acceleration time Deceleration time Braking Ambient conditions Ambient operating temperature Storage temperature Relative humidity Air quality: - chemical vapours - mechanical particles Altitude Vibration EN50178/EN60068-2-6 Shock EN50178, EN60068-2-27 EMC Immunity Emissions 8320 Hz
03000 sec 03000 sec DC brake: 30% * TN (without brake resistor), ux braking 10C (no frost)+50C: IH (FR10 + 40C) 10C (no frost)+40C: IL 40C+70C 0 to 95% RH, non-condensing, non-corrosive, no dripping water IEC 721-3-3, unit in operation, class 3C2 IEC 721-3-3, unit in operation, class 3S2 100% load capacity (no derating) up to 1000 m 1% derating for each 100 m above 1000 m; max. 3000 m (690 V max. 2000 m) 5...150 Hz: Displacement amplitude 1 mm (peak) at 515.8 Hz (FR10: 0.25 mm (peak) at 531 Hz) Max acceleration amplitude 1 G at 15.8150 Hz (FR10: 1 G at 31150 Hz) UPS Drop Test (for applicable UPS weights) Storage and shipping: max 15 G, 11 ms (in package) Full all EMC immunity requirements EMC level C: EN61800-3 (2004), category C1 EMC level H: EN61800-3 (2004), category C2 EMC level L : EN61800-3 (2004), category C3 EMC level T: Low earth-current solution suitable for IT networks, EN61800-3 (2004), category C4 (can be modied from L/H-level units) EN 50178 (1997), EN 60204-1 (1996), EN 60950 (2000, 3rd edition) (as relevant), IEC 61800-5, CE, UL, CUL; (see unit nameplate for more detailed approvals)
Safety Control connections (OPT-A1, -A2 or OPT-A1, -A3) Analogue input voltage Analogue input current Digital inputs Auxiliary voltage Output reference voltage Analogue output Digital output Relay outputs Thermistor input (OPT-A3) Protections
0+10 V (10 V+10 V joystick control), Ri = 200 k , resolution 0.1%, accuracy 1% 0(4)20 mA, Ri = 250 differential, resolution 0.1%, accuracy 1% 6, positive or negative logic; 1830 VDC +24 V, 15%, max. 250 mA +10 V, +3%, max. load 10 mA 0(4)20 mA; R L max. 500 , resolution 10 bit, accuracy 2% Open collector output, 50 mA/48 V 2 programmable change-over (NO/NC) relay outputs (OPT-A3: NO/NC+NO) Switching capacity: 24 VDC/8 A, 250 VAC/8 A, 125 VDC/0.4 A. Min. switching load: 5 V/10 mA Galvanically isolated, R trip = 4.7 k Overvoltage, undervoltage, earth fault, mains supervision, motor phase supervision, overcurrent, unit overtemperature, motor overload, motor stall, motor underload, short-circuit of +24 V and +10 V reference voltages
23
Vacon Plc Runsorintie 7, 65380 Vaasa, Finland Tel. +358 (0)201 2121, Fax +358 (0)201 212 205 www.vacon.com, e-mail: [email protected]
Vacon Partner
BC00167D