BERMAD Fire Protection

400 Series

Pressure Relief Valve


with Electric Override

Model: FP 430-59

Description
The BERMAD Model FP 430-59 combines fire pump relief with a pre-opening feature to anticipate pump start-up surge. The valve opens fully by means of electric override upon pump start-up, and continues to function as a pressure relief valve. The valve performs reliably in high capacity fire pump systems.

Typical Applications
Individual high capacity fire-pumps

Features and Benefits


Hydraulically powered valve design Eliminates jamming problems Closes drip-tight time after time One-piece molded elastomeric moving part No maintenance required Dual pilot valve parallel system, hydraulic & electric Quick response with minimal power requirement Continues to act as relief valve upon electric failure Hydro-efficient body design Wide rangeability Unrestricted flow path In-line servicable minimal down time

Petrochemical complexes and refineries

Harbors and Airports

Foam recirculation; maintains required foam pressure

Optional Features
Hazardous locations solenoid Electric limit-switch and/or valve position flow indicator Large control filter (code: F) Seawater service construction Valve Position Single/Double Limit Switches

Note: Optional features can be mixed and matched. Consult your local BERMAD representative for full details

BERMAD Fire Protection


Model: FP 430-59

400 Series

Operation
The BERMAD Model FP 430-59 is equipped with 2 parallel control systems to provide both pressure relief (via hydraulic pilot valve) and pump start-up surge anticipation (via solenoid valve): Simultaneously with electrically powering the pump to start, an electric command is sent to the Solenoid Valve [1]. This fully opens the main valve, ensuring that pump start-up sudden flow and pressure surge will be relieved and will not cause a water hammer effect. Via a timer, the electric power is kept active long enough to ensure functionality. After the electric command is turned off, the pump pressure relief feature remains active. When the Pressure Sustaining (PS) Pilot [2] senses upstream pressure that is higher than its set point, it acts upon the main valve control chamber [3] causing the main valve to modulate open, relieving excess pressure to either a reservoir or sump. The PS Pilot is equipped with an adjusting screw [4] to preset the desired upstream pressure and an integral needle valve [5] to control the main valve closing speed. [4]

[4] [2] [5]

[2]

[1]

[1] [5] [3]

[3]

1.5 - 4 Configuration (Close)

6 - 12 Configuration (Close)

Engineer Specifications
The pressure relief valve shall be both solenoid pilot and hydraulic pilot controlled. The main valve shall be an elastomeric type globe valve with a rolling-diaphragm. Valve actuation shall be accomplished by a fully peripherally supported, one-piece balanced rolling-diaphragm vulcanized with a rugged radial seal disk. The diaphragm assembly shall be the only moving part. The valve shall have an unobstructed flow path, with no stem guide or supporting ribs. The valve shall have a removable cover for quick in-line service enabling all necessary inspection and servicing. The pilot system shall be field adjustable, with adjustable valve closing speed, integrated into the main valve, hydraulically-tested and supplied as an assembly consisting of: Relief pilot valve with built-in, internal needle valve (6-12 only) Solenoid valve Y strainer The control line shall be supplied as an assembly, pre-assembled and hydraulically tested at an ISO 9000 and 9001 certified factory.

BERMAD Fire Protection


Model: FP 430-59

400 Series

Typical Installations
System Components
1 2 3 4 BERMAD Model FP 430-59 Fire Pump Check Valve Pressure Gauge

2 4 3 1

Installation Considerations

Valve size should be no less than NFPA-20 requirements. Provide adequate clearance around valve for maintenance, ensuring that the actuator can be easily removed. Design installation with the valve cover up for best performance. Ensure that before the valve is installed, pipeline is flushed at full flow.

BERMAD Fire Protection


Model: FP 430-59

400 Series

Technical Data

Th

Tw L1, L2

Size Dimensions L1 (1) L2 (2) Tw Th

2 mm 205 180 284 210 inch 8 1/2 7 1/16 11 /16


3

2 mm inch 205 8 1/2 210 284 210 8 1/4 11 /16


3

3 mm 257 255 300 215 inch 10 1/8 10 1/16 11 /16


3

4 mm 320 N/A 313 243 inch 12 9/16 N/A 12 /16


5

6 mm 415 N/A 341 315 inch 16 5/16 N/A 13 /16


7

8 mm 500 500 415 350 inch 19 11/16 19 11/16 16 5/16 13 3/4

10 mm inch 605 23 13/16 N/A 443 382 N/A 17 7/16 15

12 mm inch 725 28 1/2 N/A 481 430 N/A 18 15/16 6 15/16

8 1/4

8 1/4

8 7/16

9 9/16

12 3/8

Notes: 1.L1 is for flanged valves. 2. L2 is for threaded NPT or ISO-7-Rp. 3. Tw & Th are max. for pilot system.

4. Data is for envelope dimensions, component positioning may vary. 5. Provide space around valve for maintenance.

Connection Standard Flanged: ANSI B16.42 (Ductile Iron), B16.5 (Steel & Stainless Steel), B16.24 (Bronze) ISO PN16 Threaded: NPT or ISO-7-Rp for 2, 2 & 3 Grooved: ANSI/AWWA C606 for 2, 3, 4, 6 & 8 Water Temperature 0.5 50C (33 122F)

Available Sizes Globe: 2, 2, 3, 4, 6, 8, 10 & 12 Angle: 2, 3 & 4 Standard Pressure Rating Max. inlet: 175 psi (12 bar) Set: 30 - 175 psi (2 - 12 bar) Test: 365 psi (25 bar)
* Pressure rating might be limited due to solenoid valve rating

Approvals ABS Lloyds Registered

Manufacturers Standard Materials


Main valve body and cover Ductile Iron ASTM A-536 Main valve internals Stainless Steel & Elastomer Control Trim System Brass control components/accessories Stainless Steel 316 tubing & fittings Elastomers Polyamide fabric reinforced Polyisoprene, NR Coating Electrostatic Powder Coating Polyester, Red (RAL 3002)

Optional Materials
Main valve body Carbon Steel ASTM A-216 WCB Stainless Steel 316 Ni-Al-Bronze ASTM B-148 Control Trim Stainless Steel 316 Coating Fusion-Bonded Epoxy with UV Protection, Anti-Corrosion High Build Epoxy

Solenoid Pilot Valve


Standard 2-Way (6-12) / 3-Way (2-4), direct type Brass body Main valve closed when de-energized Enclosure: General purpose watertight, NEMA 4 and 4X / IP65, Class F Power: 24VDC, 8 watts UL - Listed Options (see also ordering guide) Hazardous locations: Class l Division 1, Gr. A, B, C, D, T4 (code 7) Class l Division 2, Gr. A, B, C, D, T4 ATEX, EEx d llC T5 (code 9) Voltage: see ordering guide (voltage option table) Stainless steel 316 body material (code K)

bermadfir [email protected] www .bermad.com