Copyright Innovative Technology Limited 2005
Caution This Product must be fitted with a 2 Amp fuse before use. The NV9 Validator is pin for pin compatible with NV7/8/10 but NOT pin for pin compatible with the NV2/3/4/4X or 5 series products.
We recommend that you study this manual as there are many new features permitting new uses and more secure applications. If you do not understand any part of this manual please contact the factory for assistance. In this way we may continue to improve our product. Alternatively visit our web site at www.innovative-technology.co.uk
Innovative Technology Ltd. Derker Street Oldham England OL1 4EQ Tel: +44 (0) 161 626 9999 Fax: +44 (0) 161 620 2090 Email: [email protected] Web site www.innovative-technology.co.uk
Smiley and the ITL Logo are international registered trademarks and they are the property of Innovative Technology Limited. Innovative Technology has a number of European and International Patents and Patents Pending protecting this product. If you require further details please contact the factory. Innovative Technology is not responsible for any loss, harm, or damage caused by the installation and use of this product. This does not affect your local statutory rights. If in doubt please contact Innovative Technology for details of any changes
5 of 38
Copyright Innovative Technology Limited 2005
Although information is included which will allow a degree of fault diagnosis and repair, it is recommended that for all but simple mechanical repairs the unit be returned to an approved service centre for repair.
Caution: Never exceed the recommended environmental and electrical limits. Do not attempt to lubricate the mechanisms as this may affect the note transport. Do not polish the lens as this may alter the optical characteristics. If the NV9 Validator is disassembled the unit must be re-calibrated/re initialised, following reassembly.
Innovative Technology Ltd has a policy of continual product improvement. As a result the products supplied may vary from the specification described here.
6 of 38
Copyright Innovative Technology Limited 2005
Minimum +3oC 5%
Caution: If the input voltage falls below 11V the NV9 may not operate correctly (will reject notes). The amber status LED and front bezel lights will flash to indicate incorrect conditions It is recommended that the power supply used can supply at least 1.5Amps. Minimum 11V 18V 0 Maximum 15V 42V 0.25V @100 Hz 0.35A 1A 1.5A
Electrical Supply Supply Voltage (V dc) Absolute Limits MDB IF5 Version Supply Voltage Supply Ripple Voltage Supply Currents: Standby Validating Peak (Stacker Motor stall)
7 of 38
Copyright Innovative Technology Limited 2005
Interface Connector
Vertical And Horizontal Bezel Figure 1 The NV9 with Vertical and Universal Bezels The NV9 Validator leaves the factory preset to at least one currency so that it is ready for immediate installation. If it is required to change the currency data set this may be done using either the NV9 to NV9 currency cloning system or the PC based Currency Management software. New currencies and applications are being tested all the time, please refer to our web site or contact the factory for information concerning specific currencies if they are not already included on our approved list. The NV9 is designed for easy installation in most machines. The stepped smiling mouth allows insertion of notes with one hand and simplifies the note handling mechanism. Interfacing the Validator is very simple, with the choice of the following protocols: Parallel open collector outputs. Pulse stream open collector output. Binary open collector output. Smiley Secure Protocol (SSP) secure serial communications. Simple serial I/O communications. MDB interface protocol. CCTalk Extended Interface / USA Serial
8 of 38
Copyright Innovative Technology Limited 2005
ON
DIP
AMBER
GREEN
RED
STATUS
2 Pulse Multiplier
S.S.P.
Special
Figure 2 - User Display and DIPswitch Settings
5.1:DIPswitch Settings
The four DIPswitches can be set to a combination of either up required for the particular NV9. Switch 1 Spare Switch 1 currently has no function and is reserved for future use. Switch 2 pulse multiplier This switch is used to modify the behaviour of the selected machine interface. Details of the function of this switch are covered in the interfaces description in this manual. Currently the only interface to make use of this switch is the pulse mode. In this mode the switch can be used to multiply the number of pulses given by a factor of four. When the switch is down the multiplier is 1, when the switch is up the multiplier is 4. Switches 3 and 4 Machine Interface protocol selection These switches are used to select the machine interface to be used. The NV9 supports four interfaces, as shown below, (see table 1). or down depending on the configuration
9 of 38
Copyright Innovative Technology Limited 2005
The details of the parallel, pulse, and SSP can be found in the machine interface protocols section of this manual. The special interface depends on the firmware that is used in the NV9, the firmware shipped as standard is the binary interface (World Wide) and CCTalk (UK only). However, there are other options that can be downloaded by the user: Binary CCTalk ITL Simple serial I/O MDB
Information on each of these interfaces can be found in the machine interfaces protocol section of this manual.
LED Status Slow flashing green led Heartbeat (Slow = 1 second period) Flashing red one second period Fast flashing red (fast = half second period) Permanent Red Alternately flashing green then red Flashing amber and bezel lights
Description In normal RUN operation, when the NV9 is ready to read a note, the green status led will flash slowly ("Heartbeat") to signal a healthy status. NV9 is jammed, somewhere in the note path NV9 cannot calibrate, sensor(s) may be blocked Memory has been corrupted Stacker is full Power supply is incorrect, check specification
10 of 38
Copyright Innovative Technology Limited 2005
Interface Connector
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Vend 2 (binary bit 2) Vend 3 (binary bit 4) Vend 4 (binary bit 8) Inhibit 1 Inhibit 2 Inhibit 3 Inhibit 4 Busy Escrow Spare Spare Spare Spare +Vin 0V
11 of 38
Copyright Innovative Technology Limited 2005
Figure 4 - Input and Output Circuit All outputs are open collector transistors. All Inputs are held high to internal +5v via 10K. The input structure is a CMOS gate with anti-static protection fitted.
Interface Logic levels Inputs Outputs with 2K2 pull up Maximum Current Sink
Logic Low 0V < Low < 0.5 0.6V 50mA per output Table 4 - Interface Logic Levels
Logic High +3.7V < High <12V Pull up voltage of host interface
12 of 38
Copyright Innovative Technology Limited 2005
13 of 38
Copyright Innovative Technology Limited 2005
14 of 38
Copyright Innovative Technology Limited 2005
To use simple serial mode, DIPswitches 3 & 4 must both be up and the Simple Serial mode SIO option of the interface firmware must be loaded into the NV9. Commands are provided to fully control the operation of the NV9, the notes to be accepted and rejected can be set and a single escrow mode can be enabled. In simple serial mode single byte commands are transmitted to the Validator, the Validator echoes each valid command it receives.
15 of 38
Copyright Innovative Technology Limited 2005
1-start bit
Vend 1(pin 1) idle start bit 0 0
8-data bits
2-stop bits
300 baud.
bit 1 0
bit 2 3.3ms 1
bit 3 0
bit 4 1
bit 5 0
bit 6 0
bit 7 0
stop = 20dec
stop
idle
Figure- 5 Typical Serial Output: Transmission of the value 20 (decimal), Note not recognized The NV9 will receive and transmit the following event codes: NV9 Recognised Receive Codes
MESSAGE Inhibit C1 Inhibit C2 Inhibit C3 Inhibit C4 Inhibit C5 Inhibit C6 Inhibit C7 Inhibit C8 Inhibit C9 Inhibit C10 Inhibit C11 Inhibit C12 Inhibit C13 Inhibit C14 Inhibit C15 Inhibit C16 Un-inhibit C1 Un-inhibit C2 Un-inhibit C3 Un-inhibit C4 Un-inhibit C5 Un-inhibit C6 Un-inhibit C7 Un-inhibit C8 Un-inhibit C9 Un-inhibit C10 Un-inhibit C11 Un-inhibit C12 Un-inhibit C13 Un-inhibit C14 Un-inhibit C15 Un-inhibit C16 Enable serial escrow mode Disable serial escrow mode Accept Escrow Reject Escrow Status Enable all Disable all DECIMAL VALUE 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 170 171 172 173 182 184 185
16 of 38
Copyright Innovative Technology Limited 2005
17 of 38
Copyright Innovative Technology Limited 2005
For detailed information and full protocol specification please refer to SSP Specification ITL Drawing GA 138, this is available from the ITL website www.innovative-technology.co.uk. To help in the software implementation of the SSP, ITL can provide sample C Code, DLL controls and Visual Basic applications on request. Please contact [email protected].
18 of 38
Copyright Innovative Technology Limited 2005
MDB defines a serial bus interface used in electrically controlled vending machines (see figure 6). This is a 9600 Baud Master-Slave system where the NV9 banknote validator is a slave to a master controller. A master has the capability of communicating with 32 peripherals or slaves. The master is defined as the Vending Machine Controller (VMC). NV9 MDB Slave Receive
Transmit
Figure 6 MDB Opto Isolated Input / Output circuits The NV9 banknote Validators have a unique address 00110XXX binary (30H). The VMC polls the bus to detect presence of the NV9 Validators or get information on the current status of the Validators. The Validators will respond when asked for activity with an acknowledgment, a negative acknowledgment or a specific reply, depending on its current status. Bus crashes are avoided as the Validators respond to being polled only by the VMC. The international country code must be set for the country in which the Validators will be operating. This is the international telephone code for that country. The code is represented as two bytes For the USA the country code is 00 01 For Great Britain the code is 00 44 The scaling factor must also be specified for each Validator. All accepted note values must be evenly divisible by this number. This number would be set to 100 (Hex 64) for the Euro or Great Britain. The number would be set to 1000 (Hex 03E8) for Romania. The number of decimal places must also be programmed for each Validator The number would be set to 2 for Euro or USA The number would be set to 3 for Romania 5 would be displayed as 5.00 10 would be displayed as 10.00 19 of 38
Copyright Innovative Technology Limited 2005
Figure 7 - CCTalk Connection Pins on the NV9 The default encryption key will be set to the key code printed on the label on the NV9. If the key is changed to a new stored key by the host machine, the key can be reset to the default by the following the steps below. 1. Power off NV9. 2. Set all 4 DIPswitches to the Up position. 3. Apply power (no CCTalk comms). 4. Red LED will now be flashing. 5. Set DIPswitches 1 and 2 down. The code is now reset. 20 of 38
Copyright Innovative Technology Limited 2005
Connection Details:
NV9 15 16 6 7 2 1 3
21 of 38
Copyright Innovative Technology Limited 2005
Figure 8 Cloning Kit 2 Start-up configuration Remove power from slave and master units. Set DIPswitches 3 up and 4 down to select SSP interface mode on both NV9s. Using the NV9 cloning kit (CK2) connect the two units together as above. Turn on the 12V supply. The Master unit will update the slave firmware if the version of the Master is greater than the slave. If the master firmware is less than the slave, then the copy process is aborted. If the firmware on the master and slave are the same only the currency will be transferred.
22 of 38
Copyright Innovative Technology Limited 2005
Firmware copy: Caution: If master RED LED changes to slow blink (1 per second) then communication has been lost and copying should be restarted from beginning. Master RED LED will blink rapidly during firmware copy (the LED will pause from time to time). When the firmware copy is complete, the Slave will reset and Master unit will wait to re-establish communications. (LED flashes as at first stage power-up). When slave is ready, master will initiate currency data copy.
Currency copy: Caution: If master RED LED changed to slow blink (1 per second) then communication has been lost and copying should be restarted from beginning. Master GREEN LED will blink rapidly during the currency copy process and the LED will pause from time to time. When currency copy is complete, Master will show GREEN and RED LEDs continuously and slave will reset. NV9 NV9 copy is now complete.
23 of 38
Copyright Innovative Technology Limited 2005
Bezel
Locating Pins
Figure 11 - Clip On and Slide in Cash Boxes 300 Note Clip (part no PA185) on for the vertical bezel options only. 300 Note Slide in (part no PA192) for both the horizontal and vertical bezel options. 600 Note Clip on (part no PA193) for the vertical bezel options only. 600 Note Slide in (part no PA194) both the horizontal and vertical bezel options. 300 Note Lockable for the horizontal bezel option only (part no PA186). (Lock is not supplied use with Baton Lock type 6086-00KAL06 with supplied cam)
24 of 38
Copyright Innovative Technology Limited 2005
10.1 Cleaning
CAUTION: DO NOT USE SOLVENT BASED CLEANERS SUCH AS ALCOHOL, PETROL, METHYLATED SPIRITS, WHITE SPIRIT or PCB CLEANER. THIS WILL RESULT IN PERMANENT DAMAGE TO THE VALIDATOR, ALWAYS USE A MILD DETERGENT. To clean, slide the red release catch on the end of the NV9 Validator to open the note path. The note path and lozenge are now exposed for cleaning. Carefully wipe the surfaces with a soft lint free cloth that has been dampened with a water and mild detergent solution (i.e. household washing up liquid). Take particular care around all the sensor lenses (see figure 12), ensuring they are clean and dry. Caution When cleaning the recessed Front Sensors, use a small soft brush or cotton wool bud. If a lens has become badly scratched do not attempt to polish it. Contact ITL for further advise, as there may be damage to the optical properties of the lens.Figure 12 - NV9 Sensors Red Release Catch
Start Sensor
Rear Sensor
Optical Sensor
25 of 38
Copyright Innovative Technology Limited 2005
Belts Lozenge
Note Path
Figure 13 - NV9 Note Path and Lozenge Access Debris Clearing Examine the note paths, lozenge and note stacker for any dirt or debris. Carefully clear and wipe the surfaces of the note paths and lozenge with a soft lint free cloth that has been dampened with a water and mild detergent solution (i.e. household washing up liquid.). Take particular care around all the sensor lenses (see figure 12), ensuring they are clean and dry. Check that the note stacker and cash box spring plate are not jammed. Belt Changing With the NV9 lozenge exposed (see figure 13) carefully unplug the bottom connector of the top to bottom cable assembly from the lozenge. Remove and place the lozenge on a clean dry surface and remove the belts, sliding them off the smallest wheels first. Replace the belts using the reverse procedure from the above.
26 of 38
Copyright Innovative Technology Limited 2005
YES
NO
Check the correct cash box for the NV7 is fitted Finish
Notes pass through the validator but do not give a vend signal
YES
NO
YES
NO
27 of 38
Copyright Innovative Technology Limited 2005
YES
NO
Check jumper cable is connected from the top to bottom of validator Test the Cable
Check inhibits
NO
YES
YES
Finish
28 of 38
Copyright Innovative Technology Limited 2005
29 of 38
Copyright Innovative Technology Limited 2005
30 of 38
Copyright Innovative Technology Limited 2005
31 of 38
Copyright Innovative Technology Limited 2005
32 of 38
Copyright Innovative Technology Limited 2005
33 of 38
Copyright Innovative Technology Limited 2005
34 of 38
Copyright Innovative Technology Limited 2005
100ms
100ms
Escrow held low Inhibit rejection can be at any time during the 30 second decision period after completion of the vend
Inhibit
Figure 19 - Escrow Timing Diagram for Parallel Vends If the host machine itself aborts the transaction by setting the corresponding inhibit input high on pin 10, the note is returned immediately. The sequence of operations is as follows: 1. Pin 10 held low awaiting note insertion. 2. Note inserted. Validator issues a 100ms pulse on the appropriate channel. 3. The host machine initiates vend process. 4. The host machine sets pin 10 high to indicate that it wants the note. If this is not done within 30 seconds the Validator will return the note. 5. The Validator issues a 100ms pulse on the appropriate channel after pin 10 going high to indicate final acceptance of the note. If the signal has not been received within 30 seconds it indicates the customer has forcibly retrieved the note and the vend will be aborted. 6. The vend process is completed. 7. The host machine sets pin 10 low in expectation of the next vend. The host machine can force the return of the note to the customer by setting the inhibit line high, at any time before the end of the 30 second time-out. For channels above 4, setting all the inhibits high will cause a note reject. In the event of a note being forcibly removed from the mouth of the NV9 during the 30 second interval, the NV9 will go out of service for 45 seconds. Note: Escrow Control (SSP mode): Escrow is also possible using the SSP serial Interface. Please refer to SSP Specification GA138 available on the website www.innovative-technology.co.uk.
35 of 38
Copyright Innovative Technology Limited 2005
The DA1 and DA2 Kit comprise of the following components: DA1 DA1 adapter board (PA167) NV9 Adapter to Validator cable (C ITL Support CD-ROM for DA1 Power Cable Installation Guide DA2 DA2 adapter board USB type-A to Type-B cable ITL Support CD-ROM for DA2 DA2 to NV9 cable Power Cable Installation Guide
Connecting a DA1 to a validator and PC If you are using Windows 95/98/NT/XP, Pentium ( Microsoft and Intel) operating systems connect the DA1 to the validator as shown below (see figure 1), using the 16-way to 5-way connector. The 3.5mm jack plug and 2 banana plugs are used to supply power to the DA1. Connect +12 volts to the red banana plug and GND (0V) to the black plug. Plug the 9-way D-type connector into the serial port of the PC and note of the number of the port, as this will be needed later for configuring the software. Once the connections have been made install the appropriate software for the validator you are using.
Figure 1 - Connecting DA1 to a NV9 and PC for upgrading Connecting a DA2 to a validator and PC If you are using Windows Pentium ( Microsoft and Intel) 98, 98SE, 2000, XP Home or XP Professional operating systems, connect the DA2 to the validator as shown below (see figure 2), using NV9 TO DA2 connector. The 3.5mm jack plug and 2 banana plugs are used to supply power to the DA2. Connect +12 volts to the red banana plug and GND (0V) to the black plug. Plug the USB type Connector into the USB port of the PC. Once the connections have been made install the appropriate software for the validator you are using.
Validator
PC USB Port + 12V DC
Figure 2 - Connecting DA2 to a NV9 and PC for upgrading Software Installation To install the software to upgrade datasets and firmware, insert the CDROM into the PC drive. An installation menu will appear, select the product that you wish to download, and select the software you wish to use. Follow the onscreen instruction to complete the installation. Instructions for configuring and using the software you have installed can by found in the online help for that software. Please contact [email protected], if you require further assistance. 36 of 38
Copyright Innovative Technology Limited 2005
Please move mouse cursor over the support button and click on Currency Downloads!
If you are already registered , please type in your self - given user name and password !
37 of 38
Copyright Innovative Technology Limited 2005
For your registration we need a valid e-mail adress. Here you can choose a user name which you will need to log in. For a job description you can select one of the listed occupations.
After you filled in all informations, please click on Register Details! Approx. 10 mins later your account will be ready for your log in.
38 of 38
Copyright Innovative Technology Limited 2005