SL A Reg-Access SW Release Notes - Ver1.3 IDC4

Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

SAGEM LINK A High Capacity New Agent Software Release Notes

IDC Version: idc_swr_4.95s30 SFD Version (Package): SFD_4.95s30

Feb 2008

Proprietary and Confidential

0. Table of Contents

0. 1. 2. 3. 4. 5. 6. 7. 8. 9.

Table of Contents Document Control Introduction Supported Systems and Configurations SW/HW Configurations and Compatibility NSV Content New Features Modified Features Features Not Supported Limitations

2 3 4 5 7 10 12 13 14 15 16 17 19 23 27

10. Corrected Bugs 11. Open Bugs 12. Products and Features Description 13. Software Upgrade Procedure 14. System Information

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

1. Document Control
SAGEM Communications Project: Document Name: S5 release 1500P High Capacity New Agent Release Notes idc_swr_4.95s19nc

Publication History Revision Rev 1.0 Rev 1.1 Rev 1.2 Date 21/Dec/06 14/Feb/07 11/Mar/07 Release version Mux FW, 3156 MRMC and RFU bug fixes Add note for 2+2 XPIC Diversity (page 6 line 10) Emphasizing SW requirement with new IDM HW (page 9 sec 4.2) Rev 1.3 Rev 1.4 10/Apr/07 28/Feb/08 New/old IDMs compatibility in XPIC, MIB compilation and new IDM QPSK support bug fixes Bug fix errors during Tx power/temperature changes with 1500HP RFUs Notes

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

2. Introduction
This NSV includes new software package for the 1500P High Capacity product line that includes 1xSTM-1/OC-3, 2xSTM-1/OC-3, 1xDS3 and 3xDS3 interfaces. Linkpilot version 2.14 or above should be used in order to manage network elements with software versions in this NSV.

2.1 Project Release History


The following SW releases were previously released for the high-capacity Regenerator-Access product line: # 1 2 3 4 5 6 7 NSV SW Package IDC 4.07 IDC 4.52e9 IDC 4.52e10 IDC 4.60b72 IDC 4.95s19 IDC 4.95s19 IDC 4.95s20 Date Apr 2004 May 2005 May 2005 Dec 2005 Ver1.0 Jan 2007 Ver1.1 Feb 2007 Ver1.2 Apr 2007 Main Features 1500P platform introduction XPIC, HSB, Diversity Eth WSC, 311Mbps IDMs, 2+2 External Protection 1500P ODU 38GHz support (O5.49q) 1500HP RFU support, DS3 interfaces, 3128 XPIC-Diversity, IDC Eth+EOW 1500HP 11GHz support, SFD, User Channel Mux FW, 3156 MRMC and RFU bug fixes New/old IDMs compatibility in XPIC, MIB compilation and new IDM QPSK support bug fixes

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

3. Supported Systems and Configurations


3.1 Supported Systems
Supported system MRMC (Multi-Rate-Multi-Constellation) configurations (determined by modem configuration scripts): # Modem Script Bit Rate Channel BW (Occupied BW) [MHz] 28 (26) Modulation IDM Interface

1528

[Mbps] 155

128QAM

2 3

1550 3156

155 311

50/56 (45) 56 (52)

16QAM 128QAM

3150

311

50 (45) 40 (30.5) 40 (36) 10 (9) 20 (15.5) 40 (25)

256QAM 64QAM 32QAM 64QAM 16QAM QPSK

5 1540 155 6 1540W* 155 7 4410 44 8 4420 44 9 4440* 44 * New Modem script

STM-1/OC-3 3xDS3 *311Mbps using XPIC STM-1/OC-3 3xDS3 2x STM-1/OC-3 (one IDM) *622 Mbps using XPIC 2x STM-1/OC-3 (one IDM) STM-1/OC-3 STM-1/OC-3 1xDS3 1xDS3 1xDS3

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

3.2 Supported Configurations


Supported and unsupported configurations of this NSV: # 1 2 3 Configuration Supported [Yes/No] Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes No No Yes Yes No Yes No No Notes

1+0 1+1 HSB Internal Protection 1+1 Diversity (SD/FD) Internal Protection 4 1+1 HSB External Protection 5 1+1 HSB with Diversity External Protection 6 East-West 7 2+0 8 2+0 (XPIC) 9 2+2 HSB (XPIC) External Protection 10 2+2 Diversity (XPIC) External Protection 11 2+2 Diversity (XPIC) in 3128 system (2U chassis) 12 2xSTM-1/OC-3 IDMs 1+0, 1+1 (Internal Protection), East-West, 2+0 13 2xSTM-1/OC-3 IDMs 1+1/2+2 (External Protection) 14 2xSTM-1/OC-3 IDMs Diversity 15 2xSTM-1/OC-3 IDMs XPIC (622Mbps system) 16 1/3xDS3 IDMs 1+0, 1+1 (Internal Protection), East-West, 2+0 17 1/3xDS3 IDMs 1+1/2+2 (External Protection) 18 1/3xDS3 IDMs Diversity 19 1/3xDS3 IDMs XPIC 20 1xDS3 IFC with 1500HP RFU * New supported configuration

Only SD using 1500HP RFUs (IFC) Space Diversity only (no HSB or FD)

Using two 2xSTM1/OC-3 IDMs

SD using IF Combining

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

4. SW/HW Configurations and Compatibility


4.1 Supported HW Configurations
The table below summarized the different hardware options this NSV supports: # Description Marketing model SAGEM Part Number

IDC 1 IDC with 2xE1 wayside 2 IDC with 2xT1 wayside 3 IDC with Ethernet wayside for STM1 4 IDC Aux Eth for STM/DS3 (2xEth wayside with EOW) IDM 1 IDM-155 Mbps Optical interface SingleMode,1300nm, SC Connector 2 IDM-155 Mbps Optical interface Multi Mode,1300nm, SC Connector 3 IDM-155 Mbps Electrical interface CMI/1.0-2.3

15P-IDC-E1 15P-IDC-T1 15P-IDC-ETH-STM1 15P-IDC-ET-EOW for STM/DS3

06-0029-x 06-0032-x 06-0043-x 06-0053-x

15P-155-SM/SC

05-0030-x 05-0056-x (for 1500HP RFU) 05-0034-x

15P-155-MM/SC

15P-155-CMI

05-0035-x 05-0057- x (for 1500HP RFU) 05-0036-x

6 7

IDM-311 Mbps Optical interface SingleMode,1300nm, SC Connector IDM-311 Mbps Optical interface Multi Mode,1300nm, SC Connector IDM-311 Mbps Electrical interface CMI/1.0-2.3 1500P IDM Single DS3

15P-311-SM/SC

15P-311-MM/SC

05-0037-x

15P-311-CMI 15PI-DS3

05-0038-x 05-0045-x 05-0055-x (for 1500HP RFU) 05-0044-x 05-0054-x (for 1500HP RFU)

1500P IDM 3*DS3

15PI-3*DS3

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

4.2 IDC-IDM Compatibility


IDC compatibility with different IDM types: # 1 2 3 4 IDC 15P-IDC-E1 15P-IDC-T1 15P-IDC-ETH-STM1 15P-IDC-ET-EOW for STM/DS3 IDM-155 Go Go Go Go IDM-311 Go Go Go Go IDM-1xDS3 No Go Go Go Go IDM-3xDS3 No Go Go Go Go

Note: The compatibility refers to IDCs loaded with this NSV release Important note! New HW IDMs (unified IF-Modem board, ROHS compliant) requires this NSV release loaded on the IDC. New HW IDMs are clearly marked with label on IDM front panel: "Requires STM1/DS3 SW i4.95s19 or above".

4.3 IDM-ODU/RFU Compatibility


IDM compatibility with different ODU types: # IDM SL A 1 IDM 155 2 IDM 311 Go No Go* ODU 1500P 1500HP Go Go Go No Go Notes 1500SP Go No Go

Only 28MHz channels in 6-11GHz RFUs

3 IDM 1xDS3 Go Go Go Go 4 IDM 3xDS3 Go Go Go Go * Consult SAGEM in order to determine compatibility Note: The compatibility refers to IDMs connected to IDCs loaded with this NSV release All IDMs do not support "I" ODUs of any kind Operating frequency bands: Sagem Link A ODU 6-38GHz 1500P ODU 11-38GHz 1500HO RFU 6-11GHz 1500SP 6-8GHz

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

4.4 Software Upgrade Limitations


No limitation. This NSV can be downloaded on any of the above IDCs containing any previouslyreleased High Capacity Regenerator-Access software package (refer to sec 13 of this document for software upgrade procedure).

4.5 HW Compatibility in a Link


IDC compatibility o IDC with 2xE1 wayside should work with IDC with 2xE1 in external protection configuration and across the link. o IDC with 2xT1 wayside should work with IDC with 2xT1 in external protection configuration and across the link. o IDC with 2xEth wayside should work with IDC with 2xEth or 2xEth+EOW across the link. o The compatibility refers to IDCs loaded with this NSV release IDM compatibility o IDM-155 should work with IDM-155 or IDM-311 (only one STM-1/OC-3 port active) in internal/external protection configuration and across the link. o IDM-1xDS3 should work with IDM-1xDS3 or IDM-3xDS3 (only one DS3 port active) in internal protection configuration and across the link. ODU/RFU compatibility o Sagem Link A ODU should work with 1500P ODU in internal/external protection configuration and across the link. o Sagem Link A ODU should work with 1500SP in internal/external protection configuration and across the link (not XPIC). o Sagem Link A ODU should not work with 1500HP. o 1500SP should not work with 1500HP. o 1500SP and 1500HP can work with 1500P IDU type only (no Sagem Link A1500/1528).

4.6 SW Compatibility in a Link


Operating a link with new SW at one end and old SW at remote end is possible although SAGEM recommends upgrading SW on both ends of the link (and in the entire network).

New Agent Software Release Notes

Ver1.3 - IDC4.95

Proprietary and Confidential

5. NSV Content
The NSV package includes the following components: Component SFD Target Single file download package IDC Software IDC Boot Soft IDC Boot Flash Version SFD_4.95s30.sfd Remarks

IDC

Idc_swr_4.95s30nc.idn Idc_bsf_4.96.s.idn Idc_bot_3.66.s.idn

No need to upgrade in field

MUX

MUX Firmware 1xSTM-1/OC-3 IDM 2xSTM-1/OC-3 IDM 1xDS3 / 3xDS3 1xSTM-1/OC-3 IDM 2xSTM-1/OC-3 IDM

mux_reg20_81v10.frx mux_reg22_4.15.frx mux_ds3v24q6.frx mux_reg30_20v10.frx mux_reg32_4v06.frx

Internal card redesign Internal card redesign

Modem

Modem Firmware Configuration Script-1528 Configuration Script-1550 Configuration Script-3156 Configuration Script-3150 Configuration Script-1540 (64QAM) Configuration Script-1540W (32QAM) Configuration Script-4410 Configuration Script-4420 Configuration Script-4440 MRMC table

mdm_a2_3.0a.frm mdm_cfg1_2.01.cfm mdm_cfg2_2.01.cfm mdm_cfg3_2.03.cfm mdm_cfg4_2.02.cfm mdm_cfg6_2.03.cfm mdm_cfg21_2.00.cfm mdm_cfg7_2.04.cfm mdm_cfg8_2.05.cfm mdm_cfg20_2.03.cfm MRMC_tbl_0.01p.mrm For modem configuration options

MRMC Table

IDC Wayside

AUX (2xEth +EOW) 2xEth ODU Sagem Link A

wsc_10b1_6.40j.frw WSC_10b0_4.8.frw o3.32.odn o3.32.odu when upgrading from FA1500/1528 IDU o552f.odu when

ODU

ODU 1500P

o552f.odn

New Agent Software Release Notes

10

Ver1.3 - IDC4.95

Proprietary and Confidential

upgrading from FA1500/1528 IDU RFU RFU 1500HP/1500SP ODC Software RFU Firmware Mib File Linkpilot version

Titanium809a4.rft fpga_v7.fro FIBEAIR_5.00j.MIB 2.14

MIB Linkpilot

Software upgrade procedure is detailed further this document (refer to sec 13). Notes regarding ODU versions: The 1500P IDUs can work with Sagem Link A1500 ODUs and 1500P ODUs. There are different SW versions for the different ODUs. When upgrading an ODU, file with the extension ".odu" should be selected when the ODU is connected to a Sagem Link A1500/1528 IDU and file with the extension ".odn" should be selected when connected to a 1500P IDU. 1500HP RFUs can be connected only to 1500P IDUs. 1500HP RFUs have ODC software and RFU firmware versions. 1500P 11GHz The 1500P 11GHz ODU requires O5.52g SW file. This version is specifically for the 11GHz ODU. As all 11GHz 1500P ODUs are shipped from the factory with O5.52g, no need for software upgrade in any case.

New Agent Software Release Notes

11

Ver1.3 - IDC4.95

Proprietary and Confidential

6. New Features
The new features refer to the previous Regenerator NSV: IDC 4.60b72/73 from Dec 2005. Main features are explained in details further this document (see sec 12). # 1 SFD Feature Description/Notes Single File Download. Simple software download process using a single file containing the different SW and FW versions and configuration scripts. 2 3 DIR Error counter in loopback mode User Channel support Display of the files stored in the IDC. Error counter (defected blocks) was added for the IDU (IF) and ODU/RFU (RF) loopback for real-time monitoring of Rx status. New IDC HW: V.11 Asynchronous (up to 19200 baud) RS-232 Asynchronous (up to 19200 baud). V.11 Synchronous Co-Directional (64Kbps) V.11 Synchronous Contra-Directional (64Kbps) 5 New modem configurations (MRMC) Unified versions for 1500HP and 1500SP RFUs 1540W (155 Mbps, 32QAM) 4440 (DS3, QPSK) 1500HP has RFU SW and FW (FPGA) 1500SP has RFU SW only (no FW)

1500HP 11GHz RFU New product introduction

Important note! With this release new IDM HW is released to comply with ROHS requirements. The RoHS directive (European Union directive 2002/95/EC) stands for the Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment. This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants. The new IDM HW requires this NSV release loaded on the IDC. New HW IDMs are clearly marked with label on IDM front panel: "Requires STM1/OC3/DS3 SW 4.95s19 or above".

New Agent Software Release Notes

12

Ver1.3 - IDC4.95

Proprietary and Confidential

7. Modified Features
# 1 2 Feature Compression of IDC For disk space files "Loss of Protection" alarm [Internal Protection configuration only] 3 4 Unified Modem-IF board DC power switch "Loss of Protection" alarm is raised when one IDM is powered off or ejected. Alarm severity = Warning. Origin = IDC. Carrier LED = Yellow. Alarm clears when IDM is powered on or protection mode is disabled. SW support for internal hardware design change (functionality not affected). New DC input power switch without a latch. Press and hold for two seconds to power on/off the IDM. Description/Notes

New Agent Software Release Notes

13

Ver1.3 - IDC4.95

Proprietary and Confidential

8. Features Not Supported


# 1 Feature Description/Notes

2 3 4 5 6 7 8 9

Fast Ethernet (and Separate NSV releases 8E1/T1), GbE, 640P, 3200T MMC Multi Media Card EOW for 2xE1/T1 wayside IDCs E1 wayside for 1/3xDS3 IDMs EOW is available for 2xEth wayside only 1/3xDS3 IDMs can work only with IDCs equipped with 2xEth, 2xT1, 2xEth+EOW

Diversity support for 2xSTM-1/OC-3 (311Mbps) IDMs do not support diversity 2xSTM-1/OC-3 IDMs configuration XPIC support for DS3 IDMs 1xDS3 IFC with 1500HP RFU DS3 support for "I" ODUs 1/3xDS3 IDMs do not support XPIC configuration No support for 1500HP RFU space diversity using IFC (IF Combining) when connected to 1xDS3 IDMs 1/3xDS3 IDMs do not support Sagem Link A1500/1528 "I" or 1500P "I" ODUs

Pre-distortion for 1500P ODUs already sent from SAGEM do not support 1500P ODUs in field and cannot be upgraded in the field for pre-distortion support (requires factory calibration)

10 Pre-distortion for No pre-distortion support Sagem Link A1500/1528 ODUs Sagem Link A ODUs 11 Auto detection of neighbor IP 12 SNMPv3, IPv6 Manual configuration only of neighbor IP

New Agent Software Release Notes

14

Ver1.3 - IDC4.95

Proprietary and Confidential

9. Limitations
# 1 2 Limitation Description/Notes

Set default configuration Hard reset required 1540 - 155Mbps over Applicable for new IDMs sent from SAGEM only. 40MHz channels Upgrade of units already in the field needs to be verified with SAGEM (depends on Modem board version). Protection configuration changes Frequency change of remote ODU System resets Wait 3 minutes after changing protection configuration before coping configuration between IDMs ("Copy to Mate" commands) Cannot change remote ODU frequency in XPIC mode with 1500P ODUs. Workaround: change remote ODU frequency first. Wait 2 minutes between IDM and IDC reset in order to allow full power-up sequence

5 6

Longer system up time Power up with 2 IDMs 2 minutes. due to disk-on-chip unzip Power up with one IDM 2:30 minutes. and integrity check SW reset 2 minutes. 3128 2U - power down to IDC SW reset is required an IDM will not initiate a "Mate Configuration Mismatch" alarm Reset push-button disabled ODU/RFU reset after SW upgrade using SFD SW reset the IDC using Linkpilot or eject the IDC The ODU/RFU upload is followed by ODU reset that we'll cause service disruption of ~20 seconds. This cannot be disabled when using the SFD. Compared to 100m for 1500P/SP Adjacent Channel Co Polarization Every MRMC with Occupied BW < 30.5MHz is supported For MRMCs with occupied BW between 24MHz to 30.5MHz

8 9

10 1500HP - max RG223 cable length 70m 11 1500HP ACCP not supported on same OCB 12 1500HP - max bandwidth 30.5MHz 13 1500HP IFC support

New Agent Software Release Notes

15

Ver1.3 - IDC4.95

Proprietary and Confidential

10. Corrected Bugs


The corrected bugs refer to the previous Regenerator NSV: IDC 4.60b72/73. Items in RED are bug fixes from IDC 4.95s20 Apr 2007 release. # 1 Description Errors on Tx power changes or RFU temperature changes with 1500HP RFUs [rare] Notes Wrong pre-distortion values corrected

ODU mute in XPIC configuration due to wrong The fix implemented is a identification of IDU-ODU communication reliable polling of ODU status. problem. False signal degrade on Fiber/Radio alarm when PM data is cleared Continuous IDC resets in 2xEth+EOW IDCs due to floating reset signal Telnet and TFTP work only if based on standard IP/Mask subnets. For example: IP 192.xxx.xxx.xxx will not work with 255.255.0.0 mask [311Mbps IDMs] When disabling the wayside channel, the EOW will be disabled High radio errors in 3156 MRMC script [rare] STM1/STM2 line errors after multiple resets [rare] Implemented in Wayside FW wsc_10b1_6.39p.frw or later

3 4 5

6 7 8

3156 MRMC script update - mdm_cfg3_2.03.cfm

MUX FW update - mux_reg30_20v10.frx - mux_reg32_4v06.frx False "Extreme Temperature" alarm (~-10C) 9 RFU version update in 1500HP RFUs - titanium809a4.rft Compatibility of old and new HW IDMs in XPIC 10 IDC SW update configuration (no cancellation of cross- idc_swr_4.95s20.idn polarization signal) 11 No support for QPSK script with new HW IDM IDC SW update - idc_swr_4.95s20.idn 12 MIB compilation error (with certain compilers) MIB file update - FIBEAIR5.00j.mib

New Agent Software Release Notes

16

Ver1.3 - IDC4.95

Proprietary and Confidential

11. Open Bugs


# 1 Workaround Never connect Ethernet traffic to NMS port. Use designated VLANs to separate management packets from traffic. Alarm "Test#6 Failed" on power up in case of Avoid multiple resets during multiple resets under software download [rare] software download. If encountered, reset IDU 1500P ODU and 1500HP versions are missing Versions are downloaded and in the event log when downloaded using SFD. can be verified in Linkpilot IDO-ODU Communication failure due to IDC Avoid IDC hot-swap during hot-swap during "Copy-To-IDC" command "Copy-To-IDC" process, or [rare] reset the system afterwards [3xDS3] "Unexpected signal" alarm on ports 1 Reset IDM and 2 due to IDC SW reset when DS3 line loopback is active [3128 XPIC-Diversity 2U] - power down to an IDC SW reset is required IDM will not initiate a "Mate Configuration Mismatch" alarm [2+2 configuration] Active IDC software reset Force switch and then reset the will cause ~2 seconds of traffic disruption. IDC or disconnect protection IDC hot-swap will have the same effect, but cable before IDC reset the traffic disruption will be permanent. IDC software reset causes a 3 seconds traffic disruption in the left port of the wayside channel IDC reset when connecting to 1500AL (Lineto-Line ADM) when Media Specific bytes are used Description "Remote Communication" alarms (or other alarms) due to heavy load on Ethernet NMS port. The processor drops less prioritized task as it has to check each packet.

3 4

10 No Tx channel number information in Linkpilot after Set Default Configuration 11 [1/3xDS3 IDMs in 1+1 configuration] 97.5% of protection switches below 50mSec 12 [STM-1/OC3 Electrical in 1+1 internal configuration] Standby IDM reset will cause 1 bit error on Active IDM [occasional] 13 [1500HP RFU] ODC software upload might fail Repeat the upload if performed during multiple protection switches Perform ATPC settings from the 14 [3128 XPIC-Diversity ] Enabling ATPC from the Standby IDM will enable ATPC on both Active IDM local units and only the remote Active unit

New Agent Software Release Notes

17

Ver1.3 - IDC4.95

Proprietary and Confidential

15 [1500HP RFU] Reset IDM when XPIC is enabled will cause "RFU Synthesizer Unlocked" alarm the link will be down [very rare] 16 Telnet session will stuck if two attempts to connect (from different PCs) at the same time 17 Disabling the STM-1/OC-3 port will disable the Eth wayside channel 18 [1500HP/SP] False "Cable Open" alarm raised when no SW in RFU 19 [1500HP] False RFU Power Failure" alarm when RFU is muted [ occasionally] 20 IDC insertion causes radio traffic hit [rare]

Reset IDM again

Enable the STM-1/OC-3 port Ignore alarm and upload SW Ignore alarm if RFU is muted

New Agent Software Release Notes

18

Ver1.3 - IDC4.95

Proprietary and Confidential

12. Products and Features Description


12.1 SFD Single File Download
The purpose of the SFD is to provide a simple and easy software download process. It allows download of single file instead of several SW/FW files. The different SW, FW and configuration scripts that has to be download upon new release are zipped into one file named "SFD_xxx.idn (where xxx=IDC SW version name). Events of each file downloaded are displayed in the alarm log. The ODU/RFU will be uploaded automatically upon download of SFD file and default will be an upload to both ODUs/RFUs. The ODU/RFU upload is followed by ODU reset that we'll cause service disruption of ~20 seconds. This cannot be disabled when using the SFD. For upgrade purposes, this feature can be used with IDCs containing 4.52e10 version or later. Software download process: Download IDC software version SW reset IDC Download SFD file Wait until all files are downloaded and uploaded (IDU and ODU/RFU) HW reset the IDU Verify all correct files are updated in Linkpilot.

New Agent Software Release Notes

19

Ver1.3 - IDC4.95

Proprietary and Confidential

12.2 User Channel Support


Asynchronous and synchronous channels are supported in this NSV: one asynchronous per carrier (radio) or one synchronous on Channel#1 (radio right). The following UCs are supported (maimum 64Kbps over the radio): V.11 Asynchronous (up to 9600 baud) RS-232 Asynchronous (up to 9600 baud) V.11 Synchronous Co-Directional (64Kbps) V.11 Synchronous Contra-Directional (64Kbps)

. Available modes of operations are: Two V.11 Asynchronous UCs (one per radio) Two RS-232 Asynchronous UCs (one per radio) One RS-232 Asynchronous UC, and one V.11 Asynchronous UC (one per radio) One V.11 Synchronous Co-Directional or one V.11 Synchronous Contra Directional UC (mapped to CH#1)

The connector dedicated for the UC is shared with the SLIP. The system powers up with SLIP and UC disabled, and the user can choose between the two. Auxiliary channels screen of Linkpilot:

New Agent Software Release Notes

20

Ver1.3 - IDC4.95

Proprietary and Confidential

UC connector pinout: Asynchronous UC RS-232 (N.C) UC1_TxD Transmitted Data UC1_RxD Received Data (N.C) SG Signal Ground (N.C) UC2_RxD Received Data UC2_TxD Transmitted Data (N.C) Asynchronous UC V.11 UC1_TxD Synchronous UC V.11 UC_TxCLKTransmitted clock UC_TxCLK+ Transmitted clock UC_RxCLK+ Received clock UC_RxCLKReceived clock SG Signal Ground UC_TxD

Pin

Serial PPP DCD Data Carrier Detected RxD Received Data TxD Transmitted Data DTR Data Terminal Ready SG Signal Ground DSR Data Set Ready RTS Request To Send CTS Clear To Send RI Ring Indicator (N.C)

I/O

Out

UC1_TxD +

Out In/ Out* In/ Out*

UC1_RxD + UC1_RxD -

SG Signal Ground UC2_TxD . UC2_RxD +

Com

Out

UC_RxD +

In

UC2_TxD + UC2_RxD -

UC_TxD + UC_RxD -

Out

In

* Output in contra-directional mode UC connectivity can be achieved using the standard terminal cable (DB-9).

New Agent Software Release Notes

21

Ver1.3 - IDC4.95

Proprietary and Confidential

12.3 DIR Disk Files


Display of the files stored in the IDC. "Read-Only" display for information allows the user to see what SW/FW files are stored and when downloaded.

The "Sub type", "Firmware" and "Properties" are internal EPROM fields.

New Agent Software Release Notes

22

Ver1.3 - IDC4.95

Proprietary and Confidential

13. Software Upgrade Procedure


13.1 Introduction
The following section details the recommended software upgrade steps for this NSV release. In SAGEMs 1500P IDU, the IDC card (In Door Controller) stores the software, firmware and configuration scripts to the different components in the IDU and ODU. Whenever IDU/ODU initializes, the versions are loaded from the IDC. Once loaded, the IDMs/ODU can work without IDC. SAGEM releases complete software packages. When upgrading a unit, all the SW/FW components must be upgraded to assure proper operation. There are different software release packages for different products lines (High Capacity, Fast Ethernet, GbE).

13.2 Preliminary Steps


1. Record the Existing Software Versions 1.1 Launch Linkpilot. 1.2 Record the current software versions in File System Information Versions or check them using the Configuration Report. 1.3 Contact SAGEM support in order to verify that the software upgrade is possible for your current configuration. 2. Configure Linkpilot - TFTP Parameters TFTP (Trivial File Transfer Protocol) is used for software download. Its parameters should be configured using the Linkpilot configuration application. 2.1 Close any open session of Linkpilot. 2.2 Create new folder in drive C named dwld (C:\dwld) and store all download files in it. 2.3 Start Programs Linkpilot Linkpilot Configuration. The Linkpilot Configuration screen will be opened.

New Agent Software Release Notes

23

Ver1.3 - IDC4.95

Proprietary and Confidential

2.4 Select File Transfer Configuration tab. 2.5 In TFTP Server Address field enter the IP address of the PC. 2.6 In TFTP Files Location field browse and enter the folder path where the download files are located (C:\dwld). 2.7 Leave default settings in TFTP Timeout and TFTP Retries (90 seconds, 4 respectively). 2.8 In Use Internal TFTP Server field select True. 2.9 Click Apply to save changes and Close Linkpilot Configuration application.

13.3 Files Download using Linkpilot


3.1 Launch Linkpilot. 3.2 File Software Download. The Software Download screen will appear.

3.3 Verify the File Location and the TFTP Server IP Address are displayed correctly.

New Agent Software Release Notes

24

Ver1.3 - IDC4.95

Proprietary and Confidential

By clicking Select you will be able to browse for the different software versions of the different components. Only the files stored in the File Location with the corresponding file extension will be available for selection. Clicking Apply will start the download. Download status will be displayed in the Download Log. 3.4 Download the IDC software version file (idc_swr_xxx.idn). In certain cases or in case software download fails, clearing the configuration from the disk might be required. Clear_Config_Disk can be performed using the terminal: (3) Maintenance (1) IDC (5) Clear Disk Configuration. 3.5 Perform IDC SW reset using Linkpilot: Maintenance Software Reset IDC. 3.6 Download all remaining files, including IDC boot files, MUX FWs, Modem FW, Modem configuration scripts, Wayside FW, ODC and MRMC table (multiple selection is possible). 3.7 Once download completed successfully, reset IDU by powering off the IDMs or using Linkpilot: Maintenance Hardware Reset IDC. 3.8 Verify new software files were updated correctly in the Linkpilot. Important note! Typically, ODU/RFU software is not required for customer's application. Please download ODU/RFU files ONLY when actually needed after consulting with SAGEM customer support. Downloading 1500HP RFU SW and FW might take up to 25 minutes. Do not interrupt or cancel the download once started. Do not download O5.52f version to 1500P 11GHz ODU (requires O5.52gversion).

13.4 Single File Download using Linkpilot


Single File Download (SFD) provides a simple and easy software download process. It allows download of single file instead of several SW/FW files. For upgrade purposes, this feature can be used with IDCs containing 4.52e10 version or later.

4.1 Launch Linkpilot. 4.2 File Software Download. The Software Download screen will appear.

New Agent Software Release Notes

25

Ver1.3 - IDC4.95

Proprietary and Confidential

4.3 Verify the File Location and the TFTP Server IP Address are displayed correctly. 4.4 Download the IDC software version file (idc_swr_xxx.idn). 4.5 Perform IDC SW reset using Linkpilot: Maintenance Software Reset IDC. 4.6 Download the SFD file (SFD_xxx.sfd). 4.7 Once download completed successfully, reset IDU by powering off the IDMs or using Linkpilot: Maintenance Hardware Reset IDC. 4.8 Verify new software files were updated correctly in the Linkpilot.

New Agent Software Release Notes

26

Ver1.3 - IDC4.95

Proprietary and Confidential

14. System Information


The following section provides relevant information for users regarding system procedures, configurations and accessories.

14.1 Cables and Accessories


14.1.1 Cables for Ethernet Wayside Connections Cables/splitters are used for dual wayside operation and for external protection configuration. RJ-45 Ethernet cable (straight) connecting 1xEth Wayside port to hub/switch in 1+0/1+1 configuration (in 1+1 configuration the Wayside is allocated to the active IDM). Standard cable can be used. RJ-45 Ethernet cable (crossover) connecting 1xEth Wayside ports between them or to a PC. Standard cable can be used. 2-port splitter for 2xEth Wayside ports (8 pin to 2x4 pin splitter). SAGEM marketing model 15P-IDC-ET_CBL SAGEM part number WA-0140-x (x latest revision)
ch1 F 4 WA-0140-x 8 M

IDU

ch2

Protection splitter for external protection of Wayside ports (8 pin to 2x8 pin splitter). SAGEM marketing model TBD SAGEM part number WA-0188-x (x latest revision)
F 4 M WA-0140-x 8 M F 8 F 8 M WA-0188-x 8

IDU

IDU

New Agent Software Release Notes

27

Ver1.3 - IDC4.95

You might also like