Ceragon Alarms
Ceragon Alarms
Ceragon Alarms
Troubleshooting Guide
Part ID: BM-0108-0 Doc ID: DOC-00015466 Rev a.00 November 2006
Notice
This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.
Registered TradeMarks
Ceragon Networks is a registered trademark of Ceragon Networks Ltd. FibeAir is a registered trademark of Ceragon Networks Ltd. CeraView is a registered trademark of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.
TradeMarks
CeraMapTM, PolyViewTM, EncryptAirTM, ConfigAirTM, CeraMonTM, EtherAirTM, and MicroWave FiberTM, are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.
Statement of Conditions
The information contained in this document is subject to change without notice. Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.
Information to User
Any changes or modifications of equipment not expressly approved by the manufacturer could void the users authority to operate the equipment and the warranty for such equipment. Copyright 2006 by Ceragon Networks Ltd. All rights reserved.
Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: [email protected] North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: [email protected]
www.ceragon.com
European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: [email protected] APAC Headquarters Ceragon Networks (HK) Ltd. Singapore RO Level 34 Centennial Tower 3 Temasek Avenue Singapore 039190 Tel - + 65 6549 7886 Fax: +65 6549 7011
Contents
General .......................................................................................................... 1
Maintenance Policy ........................................................................................... 1 Visual Inspection............................................................................................... 1
Alarm List Table ............................................................................................ 5 Fault Isolation using Loopbacks ................................................................36 Connection Fault Guide ..............................................................................37
General
Ceragon designed FibeAir to be highly reliable and relatively maintenance free. In the event of a system failure, the system will provide detailed indications to assist troubleshooting and fault isolation. This guide explains the alarm indications of the FibeAir system, and contains procedures for troubleshooting and fault isolation.
Maintenance Policy
To ensure simple and efficient system maintenance, the on-site technician will only replace IDU, ODU, or RFU modules, and not repair them. Under no circumstance will the technician be permitted to open the equipment in order to repair a module or circuit board. Opening equipment will terminate the Ceragon warranty. Maintenance procedures the technician can perform include visual inspection, cleaning, cable/connector repair, link alignment/adjustment, and retorquing antenna mount bolts.
Visual Inspection
The following table lists the suggested preventive maintenance procedures, which include visual inspection of the equipment and verification of operational parameters. It is recommended to perform the procedures as often as local environmental conditions require. It is recommended to notify the end customer prior to performing any preventive maintenance procedures that could affect service on the circuit. What to check
IDU alarm LEDs Coax cable connection Coax cable All equipment Receive level (voltage in IDU/ODU/RFU, or using management) Torque on antenna mount bolts
Comments
If not, perform troubleshooting Clean/repair as required Replace as required Clean as required Align/adjust as required
Adjust as required
Troubleshooting Guide
The Process
Corrective maintenance consists of the steps described in the following sections. The steps provide a logical, sequential method for diagnosing and resolving system problems.
PWR (Power) LINE LOF (Loss of Frame) BER (Bit Error Ratio)
Red - power supply problem Red - no input to main channel / high BER Yellow - JO mismatch Red - radio did not recognize information frame (radio link problem/radio LOF) Red - radio BER higher than radio excessive error threshold definition (see Sonet/SDH configuration window) Yellow - radio BER higher than radio signal degrade threshold definition (see Sonet/SDH configuration window) Red - loopback is active Yellow - Protected configuration. The unit is currently passive or Tx mute is operating Red - modem unlocked Yellow - high temperature / fan problem Red - no link, or ODU power, or ODU/RFU unlocked Yellow - radio interference, or high temperature, or Rx/Tx out of range Red - RF cable open / RF cable short Red - no link / remote unit problem (red LED is lit in the remote unit) Yellow - warning in remote unit (yellow LED is lit in the remote unit)
X X
X X
X X
X X
X X
X X X
X X
LED Indications for Hitless Systems For Hitless systems, the following table lists the LEDs and their indications: LOF (LED Panel) - LOF LED Color Yellow Red Alarm Explanation Local unit receives LOF from a receive path currently not in use. Local unit receives LOF from a receive path currently in use.
LOF (Interface Panel) - ALRM LED Color OFF Red Green Alarm Explanation Hitless mode is disabled. Local unit receives LOF from the mate unit. Hitless switching can be performed, if necessary.
Local Receiver (Interface Panel) - Rx ACTV LED Color OFF Green Alarm Explanation Local receiver not in use. Local receiver in use.
If no problem is detected with any of the items above, proceed with the table below. Alarm List with Corrective Actions
Trap ID Description Insufficient system configuration for full XPIC Support 0 Probable Cause One of the system elements does not support XPIC. Or, the system is missing one of the needed elements. Corrective Actions 1) Verify the existence of all IDMs and ODU, and verify their connectivity. 2) Open the unit Alarm Log (using the element manager) and send to customer support the code at the end of the "XPIC Insufficient" event text. 1) Reset IDU. 2) Check IF cable and connectors. 3) Replace ODU. 4) Replace IDU. Replace ODU. (In XPIC configuration, the ODU may be taking the sync from the mate ODU. In that case, check if alarm persists in non-XPIC configuration.) 1) Reduce TX power gradually. 2) Replace ODU.
10
One of the system elements does not support XPIC. Or, the system is missing one of the needed elements. One of the ODU synthisizers is unlocked.
12
Trap ID
Corrective Actions 1) Check if Power Input connected to -48 VDC supply. 2) Check -48 VDC supply to the subrack. 3) Disable Power Input if you do not use redundant power feed. 1) Check that the fault is not due to rain/multipath fading or lack of LOS. 2) Check link settings (TX power,TX freq). 3) Check anttena alignment. 4) Replace local/remote ODU. 1) Check installation conditions. 2) Replace ODU. 1) Verify if the Power Input card exists in the subrack. 2) Check if Power Input connected to -48 VDC supply. 3) Check -48 VDC supply to the subrack. 4) Replace Power Input card if problem still exists. 5) Disable Power Input if you do not use redundant power feed. 1) Verify if the Power Input card exists in the subrack. 2) Check if Power Input connected to -48 VDC supply. 3) Check -48 VDC supply to the subrack. 4) Replace Power Input card if problem still exists. 5) Disable Power Input if you do not use redundant power feed. 1) Verify correct cable connection. Recommended connection is V to Right drawer and H to Left drawer
12
14
15
15
15
Left/Right cables swap in XPIC configuration. If Drawer ID Mismatch (see above) alarm is identified in both drawers, the IF (coax) cables between the drawers and ODUs on one end are swapped. Failure in an IDU power supply.
15
Trap ID 15 15
Description Drawer Power On/Off Drawer Internal Power Failure (Board #1) Drawer Internal Power Failure (Board #2)
Probable Cause Drawer power on/off. Drawer Internal Power Failure (Board #1) Board #1 - MUX card. Board #2 - Modem card. This alarm may also be generated if a drawer in Internal Protection was switched off. Problem with extension cable or the connection between the two subracks.
Corrective Actions -
15
16
1) If extended mode is not in use, configure all IDCs in the subrack as "1 subrack out of 1". 2) If extended mode is in use, verify that the other subrack is configured to extension mode properly. 3) Check that the XC boards in both subracks are inserted properly and the extension cable is plugged in. 4) Replace extension cable. 5) Replace XC boards. 1) Check IF cable and connectors. 2) Check ODU's N-type connector inner pin is not spliced (if yes, replace ODU). 3) Replace IDU. 4) Replace ODU. 1) Check IF cable and connectors 2) Check ODU's N-type connector inner pin is not spliced (if yes, replace ODU). 3) Replace IDM. 4) Replace ODU. 1) Download the Modem script to the IDC and reset the IDM.
Cable Open/Short 16
Cable Open 16
Multi-Rate MultiConstellation configuration script for the specified capacity/modulation is missing in the IDC. Drawer hardware intact ok / failure (Mux)
17
18
Trap ID 18 19
Description Fan Failure XC Internal Loopback on Line #5 XC Internal Loopback on Line #4 XC Internal Loopback on Line #3 XC Internal Loopback on Line #2 XC Internal Loopback on Line #1 Wayside Channel Loopback
Probable Cause Fan Failure XC board Internal port loopback XC board Internal port loopback XC board Internal port loopback XC board Internal port loopback XC board Internal port loopback Wayside Line loopback applied by user in internal protection Wayside Left Line loopback applied by user ODU RF loopback applied by user Loopback applied by user
19
1) Disable loopback
19
1) Disable loopback
19
1) Disable loopback
19
1) Disable loopback
19
19
Wayside Channel Loopback ODU Internal Loopback (Not) Active IDU Remote Loopback (Not) Active ?10;IDU Line Loopback (Not) Active?10;E1\T1\E3\DS 3 #n Internal Loopback (Not) Active?10;E1\T1\E3\DS 3 #n External Loopback (Not) Active Internal Loopback on Fiber #n External Loopback on Fiber #n E1\T1 Internal Loopback on Port #n IDU Local Loopback (Not) Active
19
1) Disable loopback
1) Disable loopback
19
19
1) Disable loopback
19
IDU Line loopback applied by user IDU Line loopback applied by user IDU IF loopback applied by user
1) Disable loopback
19
1) Disable loopback
19
1) Disable loopback
Trap ID 19
20
1) Verify link is up and no errors over the link. 2) Check in-band management configuration. Disable PRBS test.
21
PRBS Test is Running on Radio Link Group #1 N+1 Protection Fault: Locked by User
21
Lockout or Force Switch to Protecting Link Group maintenance command activated. Trib RS: LOF Radio RS: LOF (ADM)
22
22
1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs. 1) Check Protecting Radio module is powered on and operates properly. 2) Replace faulty module. 3) see Radio RS: LOF (SDH) 1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs/ODUs 1) Check line input. 2) Check fibers/cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDU is ok. 5) Replace IDM.
22
N+1 Link Group protection degraded due to Loss Of Frame or Loss Of Signal alarm on the radio port detected by XC board. Loss Of Frame alarm on the radio, link is down
Trap ID
Corrective Actions 1) Check line input. 2) Check fibers/cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDU is ok. 5) Replace IDU. 1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs
22
22
23
Trib RS: LOS Loss Of Signal alarm on the line input 1) Check line input. 2) Check fibers/cables. 3) Verify that end equipment transmits properly. 4) Use line loopbacks to confirm that input/IDU is ok. 5) Replace IDM. 1) Check line input. 2) Check fibers/cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDU is ok. 5) Replace IDU. 1) Check line input. 2) Check fiber. 3) Verify end equipment transmits properly. 4) Replace IDM. 1) Check line input. 2) Check cable. 3) Verify end equipment transmits properly. 4) Replace IDM. 1) Check line input. 2) Check cable. 3) Verify end equipment transmits properly. 4) Replace IDU.
23
23
23
10
Trap ID
Corrective Actions 1) Check line input. 2) Check fibers/cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDU is ok. 5) Replace IDM. Verify J0 settings in the IDU and in the end equipment. -
23
24 24 24 24 24 24 24 24 24 24 24 25 25 25 25 25
Trib RS: TIM Trib LP #n: TIM Trib HP: TIM Trace Identifier Mismatch on Fiber #n Radio LP #n: TIM Radio HP: TIM Fiber RS: TIM Fiber RS: TIM Fiber RS: TIM Fiber LP #n: TIM Fiber HP: TIM Trib RS: Excessive BER Trib MS: Excessive BER Trib LP #n Excessive BER Trib HP: Excessive BER Radio RS: Excessive BER Radio RS: Excessive BER Radio RS: Excessive BER
Trib RS: TIM Trib LP #n: TIM Trib HP: TIM Trace Identifier Mismatch alarm (J0 mismatch). Radio LP: TIM Radio HP: TIM Fiber RS: TIM Fiber RS: TIM Fiber RS: TIM Fiber LP #n: TIM Fiber HP: TIM Trib RS: Excessive BER Trib MS: Excessive BER Trib LP #n Excessive BER
Trib HP: Excessive BER Radio RS: Excessive BER (Regenerator) Radio RS: Excessive BER (Regenerator) Radio RS: Excessive BER (ADM)
25
25
11
Trap ID 25
Description Radio MS: Excessive BER Radio LP #n: Excessive BER Radio HP: Excessive BER Excessive BER on Radio #n
Corrective Actions -
25
25
25
1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs/ODUs 1) Check line input. 2) Check fibers/cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDU is ok. 5) Replace IDM. 1) Check line input. 2) Check cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDM is ok. 5) Replace IDM. -
25
Fiber RS: Excessive BER Fiber RS: Excessive BER Fiber RS: Excessive BER Fiber MS: Excessive BER Fiber LP #n Excessive BER Fiber HP: Excessive BER
Fiber RS: Excessive BER (Regenerator) Fiber RS: Excessive BER (Regenerator) Fiber RS: Excessive BER (ADM) Fiber MS: Excessive BER
25
25
25
25
25
12
Trap ID 25
Description E1\T1\E3\DS3 #n Excessive BER E1\T1\E3\DS3 #n Excessive BER Trib RS: Signal Degrade Trib MS: Signal Degrade Trib LP #n Signal Degrade Trib HP: Signal Degrade Radio RS: Signal Degrade Radio RS: Signal Degrade Radio RS: Signal Degrade Radio LP #n: Signal Degrade Radio MS: Signal Degrade Radio HP: Signal Degrade Signal Degrade on Radio #n
Corrective Actions -
25 26 26
26 26 26
26
26
26
26
26
26
1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs/ODUs 1) Check line input. 2) Check fibers/cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm that input/IDU is ok. 5) Replace IDM.
13
Trap ID
Corrective Actions 1) Check line input. 2) Check fibers/cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDU is ok. 5) Replace IDU. 1) Check line input. 2) Check cables. 3) Verify end equipment transmits properly. 4) Use line loopbacks to confirm input/IDM is ok. 5) Replace IDM. -
26
26
Fiber RS: Signal Degrade Fiber RS: Signal Degrade Fiber MS: Signal Degrade Fiber LP #n Signal Degrade Fiber HP: Signal Degrade E1\T1\E3\DS3 #n Signal Degrade E1\T1\E3\DS3 #n Signal Degrade Trib MS: AIS Trib LP #n: AIS Trib HP: AIS Radio MS: AIS Radio LP #n: AIS Radio HP: AIS Fiber MS: AIS
26
26
26
26
26
26 27 27 27 27 27 27 27
Trib MS: AIS Trib LP #n: AIS Trib HP: AIS Radio MS: AIS Radio LP #n: AIS Radio HP: AIS Fiber MS: AIS
14
Trap ID 27 27
Description Fiber LP #n: AIS Fiber HP: AIS Fiber RS: Unexpected ?10;E1\T1\E3\DS3 #n Unexpected Signal Trib RS: Unexpected Signal Gigabit Ethernet Unexpected Signal
Fast Ethernet Unexpected Signal on Port #n
Probable Cause Fiber LP #n: AIS Fiber HP: AIS Unexpected signal on the line input. Port disabled but line is connected. Trib RS: Excessive BER
28
28
28
GbE port is disabled but GbE data is detected. Fast Ethernet Unexpected Signal on Port #n Trib LP #n: LOP Trib HP: LOP Radio LP: Loss of pointer (LOP) alarm occurs. Radio HP: Loss of pointer (LOP) alarm occurs. Fiber LP: Loss of pointer (LOP) alarm occurs. Fiber HP: Loss of pointer (LOP) alarm occurs. Trib MS: RDI Trib LP #n: RDI Trib HP: RDI Radio MS: Remote Defect Identifier signal (RDI) occurs. Radio LP: Remote Defect Identifier signal (RDI) occurs.
28 30 30 30
30
30
30 31 31 31
Trib MS: RDI Trib LP #n: RDI Trib HP: RDI Radio MS: RDI
31
15
Trap ID
Probable Cause Radio HP: Remote Defect Identifier signal (RDI) occurs. Fiber MS: Remote Defect Identifier signal (RDI) occurs. Fiber LP: Remote Defect Identifier signal (RDI) occurs. Fiber HP: Remote Defect Identifier signal (RDI) occurs. Trib LP #n: PLM Trib HP: PLM Radio LP: Payload Label Mismatch (PLM) occurs. Radio HP: Payload Label Mismatch (PLM) occurs. Fiber LP: Payload Label Mismatch (PLM) occurs. Fiber HP: Payload Label Mismatch (PLM) occurs. Trib LP #n: Unequipped Trib HP: Unequipped Radio LP: Unequipped
Corrective Actions -
31
32 32 32
32
32
32 33 33 33 33 33 33
Trib LP #n: Unequipped Trib HP: Unequipped Radio LP #n: Unequipped Radio HP: Unequipped Fiber LP #n: Unequipped Fiber HP: Unequipped External Alarm
Fiber HP: Unequipped External alarm input #1 configured and triggered by user.
34
16
Trap ID
Probable Cause External alarm input #2 configured and triggered by user. External alarm input #3 configured and triggered by user. External alarm input #4 configured and triggered by user. External alarm input #5 configured and triggered by user. External alarm input #6 configured and triggered by user. External alarm input #7 configured and triggered by user. External alarm input #8 configured and triggered by user. XO failure Mux board
Corrective Actions -
35
External Alarm 36
External Alarm 37
External Alarm 38
External Alarm 39
External Alarm 40
External Alarm 41
42
1) Download correct SW/FW/Configuration scripts. 2) Replace IDM. 3) Replace IDC. 1) Download correct SW/FW/Configuration scripts. 2) Replace IDM. 3) Replace IDC. 1) Download XC firmware file of the required type and reset the IDC. 1) Replace Subrack Auxiliary module. 1) Download Wayside firmware file to the IDC and reset the IDC.
42
42
42
Wrong card type detected in Subrack Auxiliary slot. Wayside firmware file is missing in the IDC.
42
17
Trap ID
Corrective Actions 1) Check Subrack Auxiliary module is properly inserted. 2) Replace Subrack Auxiliary module. 1) Download Subrack Auxiliary firmware file and reset the IDC.
42
42
Subrack Auxiliary firmware file is missing in the 2-floor IDC. Subrack Auxiliary EEPROM checksum failure.
42
1) Extract and re-insert Subrack Auxiliary module. 2) Replace Subrack Auxiliary module. -
42
Secondary Clock Source Failure Radio module pertained to Link Protection group is powered down or extracted.
42
1) Check if Radio module is inserted properly in the subrack and is powered on. Replace module if faulty. -
42
Primary Clock Source Failure No signal detected on Subrack Auxiliary EOW chaining input.
42
1) Disable EOW chaining if not required. 2) Check EOW chaining line input on both subracks. 3) Check / fix EOW chaining configuration on mate subrack. Verify that EOW is defined on at least one working link on mate subrack. 4) Replace EOW chaining cable. 5) Perform reset to the local / mate Subrack Auxiliary module (by extracting and inserting IDC2). 6) Replace local / mate Subrack Auxiliary module. 7) Check / replace IDC2 on mate subrack. 1) Check if XC module is powered on and no other alarm pertained to XC is active. 2) Replace XC module.
42
Link Group #1 N+1 Protection Fault: Protecting Radio Failure XC Card Fault
18
Trap ID
Probable Cause N+1 Link Group protection degraded due to peer XC communication fault.
Corrective Actions 1) Verify Protection Radio link is up and, no errors over the link. 2) Check that remote IDU is properly configured for N+1 Link Group protection. 3) Check that remote IDU has properly operational XC board. 4) Check that Protection Radio link terminates over Protecting Radio module (and not other Radio module). 1) Check that remote IDU is properly configured with N+1 Link Group topology. 2) Check that remote IDU has all relevant N+1 Link Group protection line modules operational. 1) Try SW Reset affected module / IDM. 2) Power cycle or re-insert affected module / IDM. 3) Replace the module. 1) Try SW Reset affected module / IDM. 2) Power cycle or re-insert affected module / IDM. 3) Replace the module. 1) Try SW Reset affected module / IDM. 2) Power cycle or re-insert affected module / IDM. 3) Replace the module. 1) Try SW Reset affected module / IDM. 2) Power cycle or re-insert affected module / IDM. 3) Replace the module. 1) Check if the card is inserted properly in the subrack. 2) Check if own or redundant power supply / Radio module (in drawer #1) is powered on. Replace module if faulty.
42
42
Upper IDM Board (MUX or XC) EEPROM inventory information CRC error
Lower IDM Board (Modem or XC) EEPROM inventory information CRC error
19
Trap ID
Probable Cause Line module in carrrier #1 of the Link Protection group is powered down or extracted.
Corrective Actions 1) Check if the card is inserted properly in the subrack. 2) Check if own or redundant power supply / Radio module is powered on. 3) Replace module if faulty. 1) Check that proper Subrack Auxiliary module inserted. 2) Extract and re-insert Subrack Auxiliary module. 3) Replace Subrack Auxiliary module. 1) Check that IDC #n is power up and finished initialization. 2) Check & configure both IDCs with proper system configuration: System Type, Subrack#, Subrack IP Base Address, Link Group Topology. 3) Check for Hardware fault: Subrack Auxiliary module, Ethernet cable (if applicable), IDC modules. Replace faulty module. 1) Download correct SW/FW/Configuration scripts. 2) Replace IDM. 3) Replace IDC. 1) Download correct SW/FW/Configuration scripts. 2) Power IDM off/on. 3) Replace IDM. 3) Replace IDC. 1) Disable loopback
42
Internal IDC to IDC communication failure between modules requied for Link Group protection service.
42
42
42
Drawer Internal Loopback Copy IDC Configuration to Mate IDU-ODU Inner Communication Failure
42
IDC copy configuration by user in external protection IDC cannot communicate with ODC card.
42
1) Check ODU connection to the IDU. 2) Check IF cable and connectors. 3) Check ODU's N-type connector inner pin is not spliced (if yes, replace ODU). 4) Replace ODU. 5) Replace IDU.
20
Trap ID
Probable Cause IDC cannot communicate with MUX card, MUX card upload failure.
Corrective Actions 1) Reset IDU. 2) Verify correct SW version. 3) Verify correct interfaces. 4) Replace IDU. 1) Download correct Subrack Auxiliary FW file to 2-floor IDC, and then extract and re-insert Subrack Auxiliary board 2) Replace Subrack Auxiliary module. 3) Replace 2-floor IDC. 1) Download correct SW/FW/Configuration scripts. 2) Replace IDM. 3) Replace IDC. 1) Download correct SW/FW/Configuration scripts. 2) Replace IDM. 3) Replace IDC. 1) Check ODU connection to IDM. 2) Check IF cable and connectors. 3) Check ODU's N-type connector inner pin is not spliced (if yes, replace ODU). 4) Replace ODU. 5) Replace IDM. For High Power RF Unit: 1) Check BMA connector on OCB 2) Check BMA connector on RFU
42
42
42
42
42
DAC failure
42 42
Clock Unit Unlocked Clock Unit Out of Range Copy Carrier Configuration To Mate Failed/Succedded MUX Firmware File is Missing
Clock Unit Unlocked Clock Unit Out of Range Carrier configuration copied between two IDMs in protected configuration A Mux FW file is missing from the system.
42
42
21
Trap ID 42
Description Modem Firmware File is Missing TFTP IDU/MUX/ODU verxxx Download Succeeded/ Canceled/Failed Boot/IDC/MUX/ODU/Mo dem Script/Modem/ Wayside/Mrmc table/RFU FPGA File Download Succeeded <file name> IDU Configuration Download Succeeded/Error/Cance lled/Failed/Invalid File ODU SW Upload Failed
Probable Cause A Modem FW file is missing from the system. Software download operation status (from user's PC to IDC)
43
43
43
44
Software upload operation status (from IDC to ODC) Software upload operation status (from IDC to ODC) Software upload operation status (from IDC to ODC) MUX/ODU Internal Download Succeeded/Canceled/Failed /Error Firmware upload operation status (from IDC to ODC) Firmware upload operation status (from IDC to ODC) Firmware upload operation status (from IDC to ODC) WSC board configuration failure Error during reading board configuration CRC error
44
44
ODU SW Upload Canceled MUX/ODU Internal Download Succeeded/Canceled/F ailed/Error RFU FW Upload Failed
44
44
44
44
46
22
Trap ID
Probable Cause WSC board configuration failure Can't detect board configuration (can't read from E2PROM) Settings not supported by HW/SW. Mismatch in the internal protection configuration between the drawers.
46
46
1) Check if HW and SW support the requested configuration 1) Check and compare configuration 2) See mate Configuration Mismatch Alarm 1) Check the mismatch configuration in the alarms log. 2) Use "Copy to IDC" command to copy the configuration from XC to IDC, or "Copy to Drawer" for mismatch resolution. 1) Check and compare configuration 2) See mate Configuration Mismatch Alarm Set identical Link ID on both ends of the link. 1) Set identical Link ID on both ends of the link. 1) Set identical Link ID on both ends of the link. Reset IDM
46
46
46
Mismatch configuration between local IDC Database and mate IDC database
46 46
Link ID Mismatch Link ID is not identical on both ends of the link. Link ID is not identical on both ends of the link. Link ID is not identical on both ends of the link. Internal system mismatch regarding the state of the radio Mute/Unmute Incorrect Auxiliary channel configuration
46
46
Link ID Mismatch
Protection Mismatch 46
1) Check and correct configuration: Use "Copy IDC to AUX" to copy the Auxiliary channel configuration to the IDC, or "Copy AUX to IDC" to copy the Auxiliary channel configuration to the AUX
23
Trap ID
Probable Cause Incomapitibility alarm between link components. Typically refers to mixture of standard and "I" components in the link IDC MAC device failure loading with default MAC address FPGA load failure Wayside Channel
46
46
1) Download correct SW/FW/Configuration scripts. 2) Replace IDC. 1) Download correct SW/FW/Configuration scripts. 2) Replace IDC. 1) Check link connections and settings. 2) Check XPIC configuration. 3) Verify that both links are up. 4) Check XPI
46
Drawer ID Mismatch 46
Drawer receives signal of the other drawer across the XPIC link. Indicates problem in the XPIC link (such as failure in one of the transmitters or insufficient XPI) Drawer #1 receives signal of the mate drawer (#2) across the XPIC link. Indicates problem in the XPIC link (such as failure in one of the transmitters or insufficient XPI), detected by the XC board. Different configuration between the IDUs on the same side of the link Different configuration between the IDUs on both sides of the link Configuration in the IDC is different than the configuration in the drawers or in the Auxiliary channels board Configuration mismatch between two IDCs in External Protection configuration.
1) Check link connections and settings. 2) Check XPIC configuration. 3) Verify that both links are up. 4) Check XPI
46
46
46
46
1) Check and compare configuration. 2) Perform "copy to mate" from the IDC with the correct configuration
24
Trap ID
Probable Cause Configuration mismatch between two drawers in External Protection configuration.
Corrective Actions 1) Check and compare configuration. 2) Perform "copy to mate" from the drawer with the correct configuration 1) Check the mismatch configuration in the alarms log. 2) Use "Copy to IDC" command to copy the configuration from XC to IDC, or "Copy to Drawer" for mismatch resolution.
46
At least one Link Group configuration parameter in the IDC Database is different than the actual configuration in the XC. Raised only after IDC hotswap or S/W reset. At least one IDC configuration parameter in the IDC Data Base (XPIC for example) is different than the configuration in the drawers or in the Auxiliary channels. Raised only after IDC hotswap / software reset.
46
1) Check the mismatch configuration in the alarms log. 2) Use "Copy drawer to IDC" command to copy the XPIC/protection configuration from the drawer to the IDC (without reset). The process will eliminate the mismatch. The IDC parameters (IP addresses, in-band, external alarms) are not copied. 3) Use "Upload/Download Configuration" command followed by S/W reset in order to copy ALL IDC configurations to the IDC. 1) Check the mismatch configuration in the alarms log. 2) Use "Copy to IDC" command to copy the configuration from the drawer to the IDC, or "Copy to Drawer", eliminating the mismatch. However, "copy to drawer" command does not copy the protection or XPIC properties (thay are IDC parameters). IDC parameters (IP addresses, inband) are not copied. 3) Use "Upload/Download Configuration" command followed by S/W reset in order to copy ALL IDC configurations to the IDC. 1) Check the mismatch configuration in the alarms log. 2) Configure the relevant IDC with the correct values for mismatch resolution, and wait one minute for the mismatch alarm to clear.
At least one drawer configuration parameter in the IDC Database is different than the actual configuration in the drawers. Raised only after IDC hotswap or S/W reset.
46
46
At least one configuration parameter which should be equal in these two IDCs has different values.
25
Trap ID
Description Protection Internal/External Mate Not Exist Protection External Alarm Switch Hitless Protection Configuration Mismatch Protection Change to Standby
Probable Cause System configured for protection without mate connected Protection switch by external alarm Hitless is configred without protection Different faults indicate hardware failure on the drawer
47
47
47
1) Enable protection or disable hitless 1) Download correct SW/FW/Configuration scripts. 2) Replace IDM. 3) Replace IDC. -
47
47
Command was sent to remote end to switch when both local receivers identify Rx fault (for example, remote active transmitter fails) Change Master/Slave command
47
SW Mode Changed to Slave/Master?10; Change Remote Transmitter Request Sent Protection Cable Disconnected Protection Cable Disconnect/Error/Power Error/Problem?10; Master-Slave Disconnect Protection Communication Error on Cable
48
Protection Cable Disconnected Problem with protection cable or the connection between the Master/Slave IDUs
48
48
For External Protection configuration. Protection cable is connected but errors detected. Heart Beat (Trap Only) Trib HP: LOM Radio HP: Loss of Multiframe (LOM) alarm occurs.
1) Check that cable is connected properly. 2) Replace protection cable. 3) Replace IDCs
49 50 50
Heart Beat (Trap Only) Trib HP: LOM Radio HP: LOM
26
Trap ID 50
Probable Cause Fiber HP: Loss of Multiframe (LOM) alarm occurs. Left/Right receiver is used for processing data
Corrective Actions -
51
Not a real alarm since receiver switching is likely to happen during multipath fading. 1) Disable Hitless Lockout
51
Hitless switching disabled by user and locked for one of the drawers. Hitless switching disabled by user and locked for one of the drawers. Hitless Switch Locked to Self Radio by User Hitless Switch Locked to Mate/Self Radio by User
51
51
Hitless Switch Locked to Self Radio By User Hitless Switch Locked to Mate/Self Radio By User Hitless Self/Mate Receiver in user Hitless Functionality Failure
51
51
Hitless Self/Mate Receiver in user Hitless protection is not available. The link will fail in case of fade.
51
1) Hitless cable disconnected. 2) Mate IDU is off. 3) Mate IDU has an alarm that prevents it from receiving data. Same as Radio LOF alarm: 1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs/ODUs 1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs/ODUs
Permanent Radio LOF in the receiver (raised after 10 consecutive seconds of radio Loss Of Frame). Implies a permanent problem, unlike fading due to multipath condition, which is intermittent in nature.
27
Trap ID
Corrective Actions 1) Check that the fault is not due to other alarms that can lead to LOF. 2) Check link settings (TX power,TX freq). 3) Verify no interference. 4) Use loopbacks to identify problem source. 5) Replace IDMs/ODUs -
52
52
Hitless Self Radio Receiver LOF Hitless Cable Disconnect In-Band Radio PPP Link Disconnect?10;In-Band Line PPP Link Disconnect User Channel Ethernet Loss of Carrier
53
57
In-band connection over the line (STM-1/OC-3 or PPPoE) or over the radio was disconnected. User Right Channel Loss of Carrier
58
1) Check line input. 2) Verify user-end Ethernet equipment. 3) Check / replace connecting cable. 4) Replace IDC module. In case of N+1 Trunk Radio: 5) Replace Subrack Auxiliary module. 1) Check line input. 2) Verify user-end Ethernet equipment. 3) Check / replace connecting cable. 4) Replace IDC module. In case of N+1 Trunk Radio: 5) Replace Subrack Auxiliary module. 1) Check line input. 2) Verify user-end Ethernet equipment. 3) Check / replace connecting cable. 4) Replace IDC module. In case of N+1 Trunk Radio: 5) Replace Subrack Auxiliary module.
28
Trap ID
Corrective Actions 1) Check line input. 2) Verify user-end equipment. 3) Check / replace connecting cable. 4) Replace IDC module. In case of N+1 Trunk Radio: 5) Replace Subrack Auxiliary module. 1) Check line input. 2) Verify user-end equipment. 3) Check / replace connecting cable. 4) Replace IDC module. In case of N+1 Trunk Radio: 5) Replace Subrack Auxiliary module. 1) Check line input. 2) Verify user-end equipment. 3) Check / replace connecting cable. 4) Replace IDC module. In case of N+1 Trunk Radio: 5) Replace Subrack Auxiliary module. 1) Check cable. 2) Replace cable. 1) Check IF cable and connectors 2) Check that ODU's Ntype connector inner pin is not spliced (if yes, replace ODU). 3) Replace IDM. 4) Replace ODU. For High Power RF Unit: Check BMA connector center pin is not spliced both on RFU and on OCB.
58
59
60
60
Modem Script Not Supported One of the system elements does not support XPIC. Or, the system is missing one of the needed elements.
61
29
Trap ID
Probable Cause "Protection Lockout" command executed. Will lock the switching operation until removed. RFU Power Supply Failure (Vd)
61
1) Reset IDM. 2) Check IF cable and connectors. 3) Replace ODU. 4) Replace IDM. 1) Reset IDM. 2) Check IF cable and connectors. 3) Replace ODU. 4) Replace IDM. 1) Reset IDM. 2) Check IF cable and connectors. 3) Replace ODU. 4) Replace IDM. 1) Reset IDM. 2) Check IF cable and connectors. 3) Replace ODU. 4) Replace IDM. 1) Reset IDM. 2) Check IF cable and connectors. 3) Replace ODU. 4) Replace IDM. 1) Check that the fault is not due to rain/multipath fading or lack of LOS. 2) Check link settings (TX power,TX freq). 3) Check anttena alignment. 4) Check antenna connections 5) Replace local/remote ODU. 1) Check that the fault is not due to rain/multipath fading or lack of LOS. 2) Check link settings (TX power,TX freq). 3) Check anttena alignment. 4) Check antenna connections 5) Replace local/remote ODU. 1) Check installation conditions. 2) Replace RFU
62
62
62
62
64
30
Trap ID
Probable Cause RSL of Diversity channel is very low (typically below 80dBm).
Corrective Actions 1) Check that the fault is not due to rain/multipath fading or lack of LOS. 2) Check link settings (TX power,TX freq). 3) Check anttena alignment. 4)Check antenna connections 5)Replace local/remote ODU. 1) Check RFU connection to BP 2) Check that fans are connected to PS 3) Replace RFU BP cable 4) Replace specific fan or fans drawer 5) Replace RFU 1) Check RFU connection to BP 2) Check that fans are connected to PS 3) Replace RFU BP cable 4) Replace specific fan or fans drawer 5) Replace RFU 1) Check RFU IF cable connection 2) Reconnect the IF cable 3) Replace RFU 1) Reconnect XPIC clock cables at both RFUs 2) Replace XPIC cable 1) Check link performance 2) Re-perform delay calibration 3) Re-perform delay calibration in RF loopback 4) Reset the RFU 5) Replace RFU 1) Check link performance 2) Reperform delay calibration 3) Re-perform delay calibration in RF loopback 4) Reset the RFU 5) Replace RFU 1) Reconnect SFP. 2) Replace SFP. 3) Replace IDM.
65
66
Delay calibration is unseccessfull since wide or deep notch has been detected at the RX signal
70
31
Trap ID
Corrective Actions 1) Reconnect SFP. 2) Replace SFP. 3) Replace IDM. 1) Check the reason for the alarm (see the Probable Cause column) and correct it accordingly.
70
70
GbE port is enabled by the user but the system overrides this and mutes the port. This alarm may appear in the following cases: Radio LOF (local or remote), Link ID mismatch (local or remote), excessive BER (local or remote), Signal degrade (local or remote), GbE LOS (remote) HW encryption fault Encryption loss of frame
71 72
1) Reset IDM. 1) Check link staus. 2) Reset IDM. 1) Check link status. 2) Reset IDC. 3) Reset IDM. 1)Check link status.
74
No session key exchange in the allowed time One of the built-in encryption system tests failed One of the Conditional tests failed Encryption mode changed by user, will take effect after next power up. Administrator password is the default value N+1 Link Group protection degraded due to XC card fault.
75
76
77
80
Admin password in default state Link Group #1 N+1 Protection Fault: XC Card is Down
81
1) Check if XC module is inserted and powered on and no other alarm pertained to XC is active. 2) Replace XC module.
32
Trap ID
Probable Cause N+1 Link Group protection degraded due to peer XC communication fault.
Corrective Actions 1) Verify Protection Radio link is up and, no errors over the link. 2) Check that remote IDU is properly configured for N+1 Link Group protection. 3) Check that remote IDU has properly operational XC board. 4) Check that Protection Radio link terminates over Protecting Radio module (and not other Radio module). 1) Check Protecting Radio module is powered on and operates properly. Replace faulty module. 2) see Radio RS: LOF (SDH)
81
81
N+1 Link Group protection degraded due to Loss Of Frame or Loss Of Signal alarm on the radio port detected by XC board. N+1 Link Group protection degraded due to LocalRemote Protection Mismatch.
81
1) Check that remote IDU is properly configured with N+1 Link Group topology, and all protection members are configured with the same priority level (if extra traffic is configured as revertive in one subrack, it should also be configured the same in the other subrack). 2) Check that remote IDU has all N+1 Link Group protection pertained line modules operational. 3) Verify that remote subrack is not configured to lockout or forced switch mode. 4) Check that the extension cable is connected properly in the remote subrack (if extended mode is used). Release maintenance command.
81
Lockout or Force Switch to Protecting Link Group maintenance command activated. This alarm occurs when the connection between the NMS and the network element is lost. This alarm occurs when the user fails to log in to the NMS system correctly several times consecutively.
401
402
33
Trap ID
Description -
Probable Cause This alarm occurs when a secondary standby HighCapRadioNMS server tries to connect to a standalone HighCapRadioNMS server. This alarm occurs for a primary HighCapRadioNMS server when its connection to the standby HighCapRadioNMS server is lost. This alarm occurs for the HighCapRadioNMS server when the license is set to expire in less than two weeks. This alarm occurs for the HighCapRadioNMS server when the license expires. This alarm occurs for the HighCapRadioNMS server when the number of network elements exceeds the license limit. This alarm occurs for the HighCapRadioNMS server when it fails to load the license file. This alarm occurs when HighCapRadioNMS attempts to start the TFTP, but the TFTP port (69) is already bound by another process. This alarm occurs when a user is disconnected by another user.
Corrective Actions Open the main server configuration, and in the Redundancy section, change the server roll from Stand Alone to Main Server.
403
404
405
406
407
Remove some of the elements, or Contact customer support to obtain a license file for the updated number of elements.
408
The license file is probably corrupted. Contact customer support to obtain a new license file.
409
410
34
Trap ID
Description -
Probable Cause This alarm occurs when a secondary standby HighCapRadioNMS server tries to connect to a main HighCapRadioNMS server,with a different software version. The enabled feature set is not licensed.
Corrective Actions Re-install one of the servers, so that the same HighCapRadioNMS software version will be on both servers.
411
414
35
Equipment
101101110
Radio Link
Loopback FibeAir is capable of performing loopback testing at several points in the link. The test is run from the CeraView management software, or via the SNMP protocol. During the loopback test, an alarm indication will appear to remind you to cancel the test when you are done. The following loopback tests can be performed from the window: Local: y y 155 Mbps Line Interface Wayside Channel
Local IDU
101101110...
Equipment
101101110...
Modem & IF
to ODU
Local Loop y Full IDU (all three inputs through the IDU, modulator, and looped in the IF).
36
Equipment
101101110...
Modem & IF
Remote Loop Full Radio Link Loopback (local external equipment through the radio link, to the remote line interface module, back through the radio link, to the local external equipment).
Local Terminal
101101110...
Remote Terminal
Remote IDU Modem & IF Line Interface
Equipment
101101110...
Local IDU
Local ODU
37
Cable Connections Check Read and Write Communities Ping FibeAir. If ping succeeds, the problem may be with the CeraView software installation, or the computer TCP\IP stack. Check the read and write communities in FibeAir and in the management station configuration. If ping fails, there may be a network connectivity problem. A typical conflict may occur between the IDU configuration and the related CeraView parameter. In addition, the Agent Address must be identical to the IDU IP address, and the source address must be identical to the computers address. The following figure shows a typical example of IP addresses and network configuration.
38
Check the Serial Connection If the connection is via serial line, check the serial line speed in FibeAir, and in the Management station configuration. In the terminal, the serial line speed is specified using the IP Configuration menu. Check the Ethernet Connection Verify that the Management station and FibeAir IP interfaces have the same net ID. If they should not be included in the same network, check the default router address. After performing the verifications above, if there is still a problem with network connectivity, together with the system administrator check for firewalls and routing configuration errors.
39