Platinum VAX: VHF Air-Cooled TV/DAB Transmitter
Platinum VAX: VHF Air-Cooled TV/DAB Transmitter
Platinum VAX: VHF Air-Cooled TV/DAB Transmitter
TELEVISION TRANSMISSION
The Platinum VAX VHF air-cooled transmitter delivers the most advanced and proven VHF transmission platform, with exceptional power efficiency, an extended power range and a full operator feature set. These capabilities, along with the VAX transmitters flexible configurations and compact design, provide a solid foundation for broadcasters to build their network. The Platinum VAX incorporates the Harris PowerSmart solid-state architecture, along with 50-Volt LDMOS amplifier devices and the Harris Apex M2X exciter technology with RTAC, to provide todays broadcaster with leading power efficiency and unmatched signal performance. The VAX power amplifiers have a record of proven performance and reliability in the DMB 670 and Z transmitter families. This powerful blend of technologies provides best-in-class performance with respect to transmitter size, power efficiency and features. The modular design allows for simpler installation, easier maintenance and reduced total cost of ownership over the life of the transmitters. The VAX is available in very low-power to high-power output, suitable for almost any broadcast application. Designed with future broadcasting needs in mind, the VAX transmitter is capable of multiple modulation schemes for band III VHF analog or digital operation including ATSC, ATSC MDTV, DVB-T/H, DVB T2, ISDB-Tb, DAB/DMB and future digital standards. Upgrading from analog to digital or to newer digital standards is readily accomplished to further extend the capability and life of the transmitter. The VAX transmitter is available as standalone units or in single- or dual-cabinet configurations, and has digital power levels up to 12 kW ATSC, 6.4 kW DVB-T/T2, 10 kW DAB/DMB, and analog levels up to 16 kW.
PRODUCT DETAILS
Harris PowerSmart Technology Inside
With PowerSmart technology in its architecture, the Platinum VAX transmitter offers superior power and efficiency. New 50 volt LDMOS device technology delivers a dramatic increase in power density, lower operating costs and reduced cost of ownership over the life of the transmitter.
Compact Footprint
As the most compact air-cooled Band III transmitter, the Platinum VAX is ideal for crowded, shared transmitter sites. The Platinum VAX transmitter reduces facility space requirements, simplifies installation, lowers shipping costs and allows for easier maintenance.
Global Monitoring and Control
The Platinum VAX transmitter can be controlled from anywhere in the world with an intuitive browser-based GUI or SNMP over TCP/IP via a telecom or network connection with password protection.
Improved Uptime and Reduced Service Costs
Hot-pluggable, redundant power amplifier (PA) and universal power supply (PS) modules make on-air servicing easy and eliminate costly service interruptions. Light-weight universal PA pallets and universal PS modules facilitate overnight/ same-day shipping for simple, cost-effective spares holding. With lightweight subassemblies, the Platinum VAX eliminates any two-person lift requirements for routine maintenance and troubleshooting.
Smooth Upgradeability
The Platinum VAX features the Apex M2X exciter technology, allowing for a seamless transition from any analog standard to a digital terrestrial standard, or from an existing digital standard to a future standard, such as from DVB-T to DVB-T2 or from ATSC to ATSC MDTV.
NA +1 800 231 9673 CALA +1 786 437 1960 EA +44 118 964 8200 MESA +971 4 433 8250 APAC +852 2776 0628 www.broadcast.harris.com
Platinum VAX
TELEVISION TRANSMISSION
SPECIFICATIONS Specifications are subject to change without notice.
General
Frequency Range 168 to 242 MHz, in 1 Hz steps Transmission Standards ATSC, DVB-T, DVB-T2, ISDB-Tb, Analog, DAB Channel Bandwidth 1.5, 6, 7 or 8 MHz (system dependent) Rated Power Output See chart below Output Power Reduction Range 0 to -10 dB RF Load Impedance 50 ohms VSWR Protected against open or short circuit, all phase angles. Capable of operation into infinite VSWR with user-adjustable fold back threshold. Factory pre-set to 4% of nominal nameplate power (VSWR = 1.5:1) RF Output Connector N-female, 1-5/8 or 3-1/8 in. EIA (dependent upon power level, DIN 7-16 optional for lower power levels) Transmitter Dimensions Refer to Harris outline drawing 8398464263 Transmitter Weight Refer to Harris outline drawing 8398464263
AC Mains
AC Line Voltage 3 phase: 380 to 415 V, or 208 to 240 V, 50/60Hz, or Single Phase 208 to 240 V, 50/60 Hz - specify when ordering AC Line Variation 15%, between 208 to 230 V or 380 to 400 V Power Factor >0.97 (0.98 typical)
Environmental
Power Output (average) 50 W to 10 kW models available, measured before mask filter (see chart below) Systems DAB/DMB (OFDM) ETSI EN 300 401 & ETSI TR101 496-1 Power Stability 0.25 dB Harmonic/Spurious Output Complies with EN 302077-2 when used in conjunction with proper band pass filter Shoulder Before Filter 35 dB minimum, >36 to 40 dB typical Signal Inputs TI Input: BNC-female, user selectable 75 ohms or high impedance termination. 2x ETI (NI, G703) or 2x ETI (NA, G704), seamless input signal switch-over automatic optional EDI input: 10/100 Base T RJ-45, per ETSI TS 102 693 V1.1.2, 1 channel, UDP/DCP or TCP/DCP protocol Monitoring Outputs ETI Monitor 2.048 MHz Sync ETI Sync OFDM
ATSC Specification
Altitude Up to 13,123 ft (4,000 m) elevation above mean sea level Ambient Temperature 32 to 113 F (0 to 45 C) at sea level (upper limit derated 3.6 F (2 C) per 984 ft (300 m) elevation AMSL) Humidity 95%, non-condensing Cooling Method Air-cooled with internal fans, air flow front to rear (external air using optional front air plenum) Acoustic Noise <65 dBA (measured 1 m in front of cabinet. For VAX4PA systems and larger, the external input air plenum is required to meet acoustic noise specification) Frequency Stability Without precision frequency control/GPS: 150 Hz/ month (6.2 x 10-7 ppm)
External Inputs
GPS Input SMA female, 50 ohms, (+5 V DC @ 100 mA max output for active antenna) 1 PPS Input BNC female, user selectable 50 ohms or high impedance termination 10 MHz Reference Frequency Input BNC female, 50 ohms
Monitoring Outputs
Power Output (average) 60 W to 12 kW models available, measured before mask filter (see chart below) System ATSC A-53, 8-VSB DTV standard Data Input 19.39 Mb/s, Configurable as SMPTE-310M or ASI (user selectable) Impedance 7 5 ohms, unbalanced Input Connector 2 inputs, BNC female Signal to Noise (EVM) >27 dB (EVM <4%), Typical >32 dB (EVM <2.5 %) Phase Noise <104 dBc/Hz @ 20 kHz offset (ATSC A/64) Harmonic Radiation and Spurious Meets mask requirements specified in FCC 5th and 6th report and order Sideband Performance Compliant with FCC radiation mask, when measured at the output of Harris-supplied output filter
Analog
RF Monitor (exciter) SMA female 1 PPS SMA female 10 MHz SMA female
DVB-T/DVB-T2 / ISDB-Tb Specification
Power Output (vision peak of sync) 100 W to 16 kW models available, measured before IMD filter (see chart below). 10% sound Analog Television Systems CCIR G, I, K, K1, M, N Color Systems PAL, NTSC, SECAM Sound Systems Monaural, BTSC, IRT, NICAM G
Power Output (average) 50 W to 6.4 kW models available, measured before mask filter (see chart below) Systems DVB-T/H, standard EN 300744 DVB-T2, standard EN 302 755 ISDB-Tb, Brazil ANATEL standard ASI/T2MI Inputs 2 inputs BNC female; 75 ohms according to EN 50083-9 (for DVB-H 2 main/2 hierarchical Crest Factor 13 dB maximum
NA +1 800 231 9673 CALA +1 786 437 1960 EA +44 118 964 8200 MESA +971 4 433 8250 APAC +852 2776 0628 www.broadcast.harris.com
Platinum VAX
TELEVISION TRANSMISSION
Analog Video Performance
Video Input 0.7 to 1.4 V, 75 ohms, 32 dB return loss Variation of Output Power2 2% Vision Sideband Response3 PAL system G shown (other systems available) -1.25 MHz and below -20 dB or less -4.43 MHz -30 dB or less -0.75 to -1.25 MHz 0.5 dB or less -0.5 to 4.5 MHz 0.5 to -0.5 dB 5.0 MHz 0.5 to -2.5 dB 5.75 MHz and above -35 dB or less Differential Gain5 3% Differential Phase5 3 Low Frequency Linearity6 10% Incidental Carrier Phase Modulation5 2 Signal to Noise Ratio >60 dB (weighted) K Factor 2% or less with 2T sin2 pulse 20T Equivalent Gain and Delay 3% total baseline distortion Spurious and Harmonic Radiation -60 dB, or better In-Channel Intermodulation Distortion -58 dB (-60 dB typical)
Modulation Capability 120 kHz peak deviation Monaural Input Adjustable 0 to 12 dBm, 600 ohms, balanced, >30 dB return loss Pre-emphasis Selectable 75 or 50 S Frequency Response 0.5 dB, 40 Hz to 15 kHz Harmonic Distortion 0.5%, 30 Hz to 15 kHz FM Noise 60 dB RMS with de-emphasis AM Noise 50 dB RMS from 30 Hz to 15 kHz Synchronous AM Noise 40 dB RMS at 400 Hz with 25 kHz deviation IRT Sound Available NICAM Sound Available
Remote Control
Parallel Remote 25 conductor D-sub for single drive basic rack, 12 conductor terminal block (mini Wago) on deluxe rack Ethernet/SNMP RJ-45, twisted pair Compliance RoHS 2002/95/EC R&TTE 1999/5/EC Safety: EN 60215 EMC: EN 301-489-1 FCC Part 73 Manufacturing: ISO 9001: 2008
Compliance RoHS 2002/95/EC
R&TTE 1999/5/EC Safety: EN 60215 EMC: EN 301-489-1 FCC Part 73 Manufacturing: ISO 9001: 2008
1 2 3 4 5
Variation of peak output power with a change in average picture level from black to white (0% to 100%). Peak-to-peak variation of peak sync voltage during one field using field test signal per EIA-508 Response specified for transmitter operating into a resistive load of 1.05:1 VSWR. Measured using 20% peak-to-peak amplitude swept video modulation with pedestal set at 10%, 50% and 90% APL. All percentages relative to a blanking to white transition Measured using a 5-step staircase signal. Test signal #3, CCIR REC. #421-3
NA +1 800 231 9673 CALA +1 786 437 1960 EA +44 118 964 8200 MESA +971 4 433 8250 APAC +852 2776 0628 www.broadcast.harris.com
Platinum VAX
TELEVISION TRANSMISSION
VAX Power Levels
Model Number VAX-100AN VAX-50DA VAX-60AT VAX-50DV/IS/T2 VAX-250AN VAX-150DA VAX-180AT VAX-100DV/IS/T2 VAX-500AN VAX-300DA VAX-375AT VAX-200DV/IS/T2 VAX-1000AN VAX-600DA VAX-750AT VAX-400DV/IS/T2 VAX-2000AN VAX-1250DA VAX-1500AT VAX-800DV/IS/T2 VAX-3000AN VAX-1875DA VAX-2250AT VAX-1200DV/IS/T2 VAX-4000AN VAX-2500DA VAX-3000AT VAX-1600DV/IS/T2 VAX-6000AN VAX-3750DA VAX-4500AT VAX-2400DV/IS/T2 VAX-8000AN VAX-5000DA VAX-6000AT VAX-3200DV/IS/T2 VAX-12000AN VAX-7500DA VAX-9000AT VAX-4800DV/IS/T2 VAX-16000AN VAX-10000DA VAX-12000AT VAX-6400DV/IS/T2
1
Dimensions (H x W x D) 22.2 x 48.3 x 50.0 cm 8.72 x 19.0 x 19.7 in (Rack optional 1) 22.2x48.3x50 cm 8.72x19x19.7 in (Rack optional1) 22.2x48.3x50 cm 8.72x19x19.7 in (Rack optional1) 22.2x48.3x50 cm 8.72x19x19.7 in (Rack optional1) 93.2x48.3x67.4 cm 36.7x19x26.5 in (Rack optional1) 93.2x48.3x67.4 cm 36.7x19x26.5 in (Rack optional1) 93.2x48.3x67.4 cm 36.7x19x26.5 in (Rack optional1) In 44RU Rack: 219.7x59.5x94.8 cm 86.5x23.4x37.3 in (2 racks for dual drive) In 44RU Rack: 219.7x59.5x94.8 cm 86.5x23.4x37.3 in (2 racks for dual drive) In 2x44RU Racks, total: 219.7x119x94.8 cm 86.5x46.9x37.3 in In 2x44RU Racks, total: 219.7x119x94.8 cm 86.5x46.9x37.3 in
Weight (uncrated)
Number of Cabinets
Number of PA Blocks
RF Output Power (W) 100/10 50 60 50 250/25 150 180 100 500/50 300 375 200 1000/100 600 750 400 2000/200 1200 1500 800 3000/300 1875 2,250 1,200 4000/400 2500 3000 1600 6000/600 3,750 4,500 2,400 8000/800 5,000 6,000 3,200 12,000/1,200 7,500 9,000 4,800 16,000/1,600 10,000 12,000 6,400
20 kg 44.1 lb
0 or 1
20 kg 44.1 lb 25 kg 55.0 lb
0 or 1
0 or 1
25 kg 55.0 lb
0 or 1
286.5 kg 632 lb
0 or 1
301.5 kg 665 lb
0 or 1
316.5 kg 698 lb
0 or 1
541 kg 1,193 lb
1 or 2
12
580 kg 1,279 lb
1 or 2
16
658 kg 1,551 lb
24
753 kg 1,660 lb
32
Modulations AN - Analog
Platinum VAX
TELEVISION TRANSMISSION
IMAGES/DIAGRAMS
Platinum VAX - 8PA Systems
NA +1 800 231 9673 CALA +1 786 437 1960 EA +44 118 964 8200 MESA +971 4 433 8250 APAC +852 2776 0628 www.broadcast.harris.com 2012 Harris Corporation 09/12