F ASTENERS S ELF-LOCKING N YLON INSERT
SELF-LOCKING FASTENERS
Effective mounting for reusable locking threads. The thread locking performance of Type PL PEMHEX self-clinching fastener meets the applicable standards of NASM25027. A nylon hexagonal element provides a reusable, non-metallic prevailing torque thread lock. The strong knurled collar receives the installation force and resists torque. The spin resistance of the knurl greatly exceeds the torque that can be exerted by the self-locking feature. As the knurled collar is embedded in the sheet, the undercut cavity beneath the collar is filled with displaced sheet material, thereby captivating the fastener in the sheet. Type CFN broaching fasteners are available for thinner sheet, close-to-edge applications. The locking element provides prevailing torque to eliminate loosening of mating threaded hardware.
Type PL
Blue Nylon locking element identifies unified fasteners
PEM self-clinching shank and undercut is engineered to develop high pushout values.
sa l
PL-2
PennEngineering www.pemnet.com
es Fo @ r lo ac w ei es nd t p su ric pp es lie : s. co m
Type CFN
Broaching knurl creates a firm, interference-type fit resistant to rotation.
The color blue for fastener locking elements is a registered trademark. Unified fasteners have a blue nylon locking element and metric fasteners have a black nylon locking element.
Nylon locking element (blue for unified fasteners and black for metric fasteners)
Type Steel PL PL PL PL
es Fo @ r lo ac w ei es nd t p su ric pp es lie : s. co m
Stainless Steel PLC PLC PLC PLC Thread Code 440 632 832 032 A (Shank) Max. .060 .060 .060 .060 Sheet Thickness (1) (2) Hole Size In Sheet +.003 .000 .234 .265 .297 .312 C Max. D Max. E Max. T Max. .060 - .070 .060 - .070 .060 - .070 .060 - .070 .233 .264 .296 .311 .215 .246 .278 .293 .274 .305 .338 .353 .130 .130 .155 .165 Stainless Steel PLC Thread Code M3 A (Shank) Max. 1.53 Sheet Thickness (1) (2) Hole Size In Sheet +0.08 6 C Max. D Max. E Max. T Max. 1.53 - 1.78 5.98 5.52 7.01 3.56 4.2 PLC M4 1.53 1.53 - 1.78 7.5 8 7.48 7.01 8.54 PLC M5 1.53 1.53 - 1.78 7.98 7.52 8.99 4.45
All dimensions are in millimeters. Thread Size x Pitch M3 x 0.5 M4 x 0.7 M5 x 0.8 Type Steel PL PL PL
METRIC
(1) Can be used in panel thickness of .040 to .060 / 1 mm to 1.53 mm provided the fastener is not fully installed. The knurled collar must be left protruding above the sheet to the degree that the sheet thickness is less than .060 / 1.53 mm. (2) Knurled collar may fracture if fastener is used in sheets thicker than .070 / 1.78 mm and screw is tightened beyond maximum tightening torque.
PL
sa l
632
Thread Code
ZI
Finish
PennEngineering www.pemnet.com
PL-3
TYPE CFN
E
Nylon locking element (blue for unified fasteners and black for metric fasteners)
es Fo @ r lo ac w ei es nd t p su ric pp es lie : s. co m
Shank Code A (Shank) .003 Min. Sheet Thickness Hole Size In Sheet +.003 .000 C .002 D .004 E +.001 .004 T Max.
UNIFIED
Thread Size
Type
Thread Code
.112-40 (#4-40)
CFN
440
.040
.043
.152
.162
.175
.203
.104
.115
METRIC
Type
Thread Code
Shank Code
A (Shank) 0.08
C 0.05
D 0.1
E +0.03 0.1
T Max.
M3 x 0.5
CFN
M3
1.02
1.1
3.86
4.11
4.45
5.16
2.65
2.93
CFN
440
ZI
Type
Thread Code
Shank Code
Finish
sa l
Max. Temperature Limit
Standard Finishes Zinc Per ASTM B 633 SC1 (5m), Type III Colorless ZI None Passivated and / or Tested Per ASTM A380
Optional Finish Zinc Per ASTM B 633 SC1 (5m), Type II Yellow
For Use in Sheet Hardness: HRB 60 / HB 107 or Less HRB 70 / HB 125 or Less
250 F / 120 C
Carbon Steel
ZC
(1) See Performance Data chart for Type CFN on page PL-6.
PennEngineering www.pemnet.com
PL-4
INSTALLATION
1. Punch or drill the properly sized mounting hole in the
sheet. Do not perform any secondary operations such as deburring.
Type PL
Sheet thickness .060 to .070 / 1.53 mm to 1.78 mm
When it is necessary to install a Type PL fastener in a sheet whose thickness is less than the A dimension of the fastener, instead of flushing off the top of the knurled collar and the top surface of the sheet, bring the bottom of the fastener shank smooth with the underside of the sheet. This should be accomplished by setting the depth of the counterbore in the anvil to the difference between the A dimension and the sheet thickness. When this method is used, care must be taken to protect the fastener against crushing which would damage the threads. This method will also result in reduced pushout and torque-out values.
es Fo @ r lo ac w ei es nd t p su ric pp es lie : s. co m
BEFORE AFTER PUNCH
Knurled collar sits in anvil counterbore.
SHEET
ANVIL
Type CFN
sa l
PUNCH SHEET
PEMSERTER PRESSES
For best results we recommend using a PEMSERTER press for either manual or automatic installation of PEM PL, PLC, and CFN fasteners. For more information on our line of presses call 1-800-523-5321 (USA only).
ANVIL
PL-5
PennEngineering www.pemnet.com
PERFORMANCE DATA(1)
For Types PL and PLC
Thread Code UNIFIED 440 632 832 032 Max. Rec. Tightening Torque (in. lbs.) 9.3 12.9 19.1 26.0 (2) Locking Torque (in. lbs.) .5 to 5 1 to 10 1.5 to 15 2 to 18 .060 5052-H34 Aluminum Installation (lbs.) 2000 2000 2000 2000 Pushout (lbs.) 225 285 290 300 Test Sheet Material .040 5052-H34 Aluminum .060 Cold-rolled Steel Pushout (lbs.) 160 180 180 180 Torque-out (in. lbs.) 20 25 28 40 Installation (lbs.) 3000 3000 3000 3000 Pushout (lbs.) 260 290 290 350 .048 Cold-rolled Steel Pushout (lbs.) 225 270 270 310 Torque-out (in. lbs.) 20 30 60 70 Torque-out Installation (in. lbs.) (lbs.) 20 30 60 70 1500 1500 1500 1500 Torque-out Installation (in. lbs.) (lbs.) 20 30 60 70 3000 3000 3000 3000
METRIC
Thread Code M3 M4 M5
1.5 mm 5052-H34 Aluminum Installation (kN) 8.9 Pushout (N) 1000 Torque-out (N m) 2.25
Test Sheet Material 1 mm 5052-H34 Aluminum 1.5 mm Cold-rolled Steel Installation (kN) 6.67 Pushout (N) 710 Torque-out (N m) 2.25 Installation (kN) 13.34 Pushout (N) 1156 Torque-out (N m) 2.25
1.2 mm Cold-rolled Steel Installation (kN) 13.34 Pushout (N) 1000 1200 Torque-out (N m) 2.25 6.77 7.9
.169 to 1.69
.226 to 2.03
440
5
Max. Rec. Tightening Torque (Nm)
Thread Code
M3
0.75
(1) The installation, pushout and torque-out values reported are averages when all installation specifications and procedures are followed. Variations in mounting hole size, sheet material, and installation procedure will affect this data. Performance testing of this product in your application is recommended. We will be happy to provide samples for this purpose. (2) The maximum locking torque and the minimum breakaway will fall within these values for the first fifteen cycles when tested in accordance with the locking torque test procedure specified in NASM25027. (3) The maximum locking torque and the minimum breakaway will fall within these values for the first cycle when tested in accordance with the locking torque test specified in PEM spec PRS-C90.
sa l
es Fo @ r lo ac w ei es nd t p su ric pp es lie : s. co m
8.9 1290 6.77 7.9 6.67 800 3.16 13.34 1290 6.77 7.9 13.34 8.9 1330 6.67 800 4.51 13.34 1557 13.34 (3) Locking Torque (in. lbs.) Test Sheet Material .040 Cold-rolled Steel Installation Pushout Torque-out (lbs.) (lbs.) (in. lbs.)
1380
0.38 to 3
(3) Locking Torque (Nm)
1000
10
METRIC
0.042 to 0.339
4.45
44.5
0.45
Specifications subject to change without notice. Check our website for the most current version of this bulletin.