Stratix Ethernet Switch Specifications: Technical Data
Stratix Ethernet Switch Specifications: Technical Data
Stratix Ethernet Switch Specifications: Technical Data
Topic Stratix 5700 Ethernet Managed Switches Stratix 8000 and Stratix 8300 Ethernet Managed Switches Stratix 6000 Ethernet Managed Switches Embedded Switch Technology Stratix 2000 Ethernet Unmanaged Switches Accessories Additional Resources
Page 2 7 11 14 18 21 22
Total Ports 6 6 6 6 6 6 6 6 10 10 10 10 10 10 20 20 20 20 20 20
Combo Ports 2 FE 2 FE 2 GE 2 GE 2 GE 2 GE 2 FE 2 FE 2 GE 2 GE 2 GE 2 GE
SFP Slots 2 FE 2 FE 2 GE 2 GE 2 FE 2 FE 2 FE 2 FE 2 FE 2 FE
Software Type Lite Full Lite Full Lite Full Lite Full Lite Full Lite Full Full Full Lite Full Lite Full Full Full
User supply: 0.52.0 A max @ 1248V DC Alarm: 1 A @ 30V DC or 0.5 A @ 48V DC 9.5 W @ 24V DC @ 40 C (104 F) 15 W max 12.5 W @ 24V DC/40 C (104 F) 17 W max 15 W @ 24V DC/40 C (104 F) 20 W max 21 W @ 24V DC/40 C (104 F) 30 W max
50V (continuous), basic insulation type, DC power ports to ground, DC power ports to Ethernet ports, and DC power ports to alarm ports No isolation between individual Ethernet ports No isolation between console port and system Type tested at 850V DC for 60 s
Ethernet connections DC power connections Alarm connections Ground connection SFP modules(1)
RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702 0.50.8 mm2 (2018 AWG) solid or stranded copper wire rated at 75 C (167 F) or greater, 1.2 mm (3/64 in.) insulation max, 6.3 mm (0.25 in.) 0.5 mm (0.02 in.) strip length 0.50.8 mm2 (2018 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire (such as Belden part number 9318), 6.3 mm (0.25 in.) 0.5 mm (0.02 in.) strip length 4.0 mm2 (12 AWG) min, stranded copper wire 1783-SFP100FX 1783-SFP1GSX 1783-SFP100LX 1783-SFP1GLX
1784-SD1 0.23 Nm (2.0 lbin) on power and alarm connectors 0.96 Nm (8.5 lbin) max on ground terminals 1.11 kg (2.45 lb) 3 - on console and alarm ports 2 - on DC power ports 2 - on Ethernet ports None (open-style) T4 T4 1.25 kg (2.75 lb) 1.38 kg (3.05 lb) 2.04 kg (4.50 lb)
Enclosure type rating North American temp code IEC temp code
(1) SFP modules supported only on switches with combo ports or SFP slots. (2) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, surrounding air, max Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat)
595% noncondensing
Stratix 5700 Switches 2 g @ 10500 Hz 30 g 55 g Class A 8 kV contact discharges 15 kV air discharges 20V/m with 1 kHz sine-wave 80% AM from 801000 MHz 20V/m with 200 Hz 50% pulse 100% AM at 900 MHz 10V/m with 1 kHz sine-wave 80% AM from 10002700 MHz 4 kV at 5 kHz and 2 kV at 100 kHz on DC power ports 4 kV at 2.5 kHz, 2 kV at 5 kHz, and 1 kV at 100 kHz on alarm ports 4 kV at 2.5 kHz, 2 kV at 5 kHz, and 1 kV at 100 kHz on Ethernet ports 1 kV line-line (DM) and 2 kV line-earth (CM) on DC power ports 2 kV line-earth (CM) on Ethernet ports 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz 10 ms interruption on DC supply ports 1 kV line-line (DM) and 2.5 kV line-earth (CM) on power ports
Vibration IEC 60068-2-6 (Test Fc, Operating) Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock) Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions CISPR11 (IEC 61000-6-4) ESD immunity IEC 61000-4-2 Radiated RF immunity IEC 61000-4-3 EFT/B immunity IEC 61000-4-4
Surge transient immunity IEC 61000-4-5 Conducted RF immunity IEC 61000-4-6 Voltage variation IEC 61000-4-29 Damped oscillatory wave immunity IEC 61000-4-18
C-Tick Ex
Korean EtherNet/IP
(1) See the Product Certification link at http://www.ab.com for declarations of conformity, certificates, and other certification details.
20-port Switches (1783-BMS20CL, 1783-BMS20CA, 1783-BMS20CGL, 1783-BMS20CGP, 1783-BMS20CGN, 1783-BMS20CGPK) 12.7 cm (5.0 in.)
Inrush current, max Switch input rating, max Alarm relay rating, max Power dissipation Isolation voltage
75 V (continuous), basic insulation type, power to ground, power to network channels, and power to alarm No isolation between individual Ethernet ports No isolation between console port and system Type tested at 1000V AC for 60 s
Ethernet connections DC power and alarm connections Functional ground connection SFP modules(1)
RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702 0.50.8 mm2 (2018 AWG) solid or stranded copper wire rated at 90 C (194 F) or greater, 1.2 mm (3/64 in.) insulation max 3.35.3 mm2 (1210 AWG) solid or stranded copper wire rated at 75 C (167 F) or greater 1783-SFP100FX 1783-SFP1GSX 1783-SFP100LX 1783-SFP1GLX 1783-RMCF
1783-MCF
0.23 Nm (2.0 lbin) on power and alarm connectors 2 - on alarm ports 2 - on power ports 2 - on Ethernet ports None (open-style) Meets IP20 T4 T4 2 - on Ethernet ports
Enclosure type rating North American temp code IEC temp code
(1) SFP modules supported only on switches with combo ports or SFP slots. (2) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Technical Specifications - Stratix 8000 and Stratix 8300 Fiber Expansion Module
Attribute Ethernet data rate Connecting mode Optical wavelength Optical cable length, max Optical link budget Connector type 1783-MX08F 100 Mbps Full duplex 1310 nm Graded index multimode fiber; 2000 m 8 db with 62.5/125 m multimode cable 4 db with 50/125 m multimode cable IEC 61754-20 LC connector
595% noncondensing 2 g @ 10500 Hz 20 g 30 g Group 1, Class A 8 kV contact discharges 15 kV air discharges 20V/m with 1 kHz sine-wave 80% AM from 801000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 10002700 MHz 4 kV at 2.5 kHz and 2 kV at 5 kHz on power ports 4 kV at 2.5 kHz and 2 kV at 5 kHz on alarm ports 4 kV at 2.5 kHz and 2 kV at 5 kHz on Ethernet ports 4 kV at 2.5 kHz and 2 kV at 5 kHz on Ethernet ports
Conducted RF immunity IEC 61000-4-6 Magnetic field immunity IEC 61000-4-8 Oscillatory surge withstand IEEE C37.90.1 Voltage variation IEC 61000-4-29
10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz 30 A/m long duration and 300 A/m short duration at 50 and 60 Hz 2.5 kV 10 ms interruption on DC supply ports
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection "n" EN 60079-0; General Requirements (Zone 2) Korean Certification of Broadcasting and Communications Equipment, compliant with: Framework Act on Telecommunications and Radio Waves Act ODVA conformance tested to EtherNet/IP specifications
C-Tick Ex
KC EtherNet/IP
(1) See the Product Certification link at http://www.ab.com for declarations of conformity, certificates, and other certification details.
For panel-mounting, the height of the center of the mounting holes on both the top and bottom latches measures 8.73 mm (0.34 in.) above the top surface (or below the bottom surface) of the switch. On the switch base unit, the tab hole center-to-center spacing is 6.83 cm (2.69 in.). For expansion modules, the tab hole center-to-center spacing is 4.36 cm (1.72 in.).
Airflow around the switch and through the vents is unrestricted. To prevent the switch from overheating, these minimum clearances must be met: Top and bottom: 105 mm (4.13 in.) Left and right: 90 mm (3.54 in.) Front: 65 mm (2.56 in.)
10
Description
Stratix 6000 managed switch 8 ports 1 fiber SFP slot 250 mA @ 24V DC (1248V DC) CL 2/SELV 5.8 W 24.6 BTU/hr @ 60 C (140 F) 8 RJ45 10/100 full/half duplex ports, optional SFP transceiver port
Stratix 6000 managed switch 4 ports 100 mA @ 24V DC (1248V DC) CL 2/SELV 2.6 W
Power requirements Power dissipation, max Thermal dissipation, max Network ports Protocols Indicators EtherNet/IP features Switch features Options Inrush current, max Isolation voltage
TCP/IP, EtherNet/IP, Telnet, Http, DHCP, BOOTP, FTP, IGMP, SMTP 16 port indicators 3 status indicators 8 port indicators 2 status indicators
MAC ID management, bandwidth alarming, port control, link status, scaled bandwidth information, and connections active VLAN, IGMP snooping, IGMP query V1 and V2, DHCP server, BOOTP server, QoS, port mirroring 1 GB fiber-optic transceiver 2.2 A 50V (continuous), basic insulation type, power to ground and power to network channels No isolation between individual network channels Routine tested at 707V AC for 1 s RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702 0.333.3 mm2 (2212 AWG) solid or stranded copper wire rated at 75 C (167 F) or greater, 1.2 mm (3/64 in.) insulation max 3.3 mm2 (12 AWG) solid or stranded copper wire rated at 75 C (167 F) or greater 1783-SFP1GSX 1783-SFP1GLX 1.36 Nm (12 lbin) on DC power and functional ground 2 - on DC power ports 2 - on Ethernet ports None (open-style) Meets IP20 T4 T4
Ethernet connections DC power connections Functional ground connection SFP modules(1) Torque Wiring category(2) Enclosure type rating North American temp code IEC temp code
(1) SFP modules supported only on switches with combo ports or SFP slots. (2) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
11
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, surrounding air, max Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration IEC 60068-2-6 (Test Fc, Operating) Operating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock) Nonoperating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions CISPR 11 ESD immunity IEC 61000-4-2 Radiated RF immunity IEC 61000-4-3
060 C (32140 F)
595% noncondensing 2 g @ 10500 Hz 15 g 30 g Group 1, Class A 6 kV contact discharges 8 kV air discharges 10V/m with 1 kHz sine-wave 80% AM from 802000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 1V/m with 1 kHz sine-wave 80% AM from 20002700 MHz 2 kV at 5 kHz on power ports 1 kV at 5 kHz on Ethernet ports 1 kV line-line (DM) and 2 kV line-earth (CM) on DC power ports 2 kV line-earth (CM) on shielded Ethernet port 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz 30 A/m long duration and 300A/m short duration at 50 and 60 Hz 10 ms interruption on DC supply ports
EFT/B immunity IEC 61000-4-4 Surge transient immunity IEC 61000-4-5 Conducted RF immunity IEC 61000-4-6 Magnetic field immunity IEC 61000-4-8 Voltage variation IEC 61000-4-29
12
c-UL-us c-ETL-us CE
UL Listed Information Technology Equipment, certified for US and Canada. See UL File E151729. ETL Listed Industrial Control Equipment, certified for US and Canada. ETL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection "n" EN 60079-0; General Requirements (Zone 2) Korean Certification of Broadcasting and Communications Equipment, compliant with: Framework Act on Telecommunications and Radio Waves Act ODVA conformance tested to EtherNet/IP specifications
C-Tick Ex
KC EtherNet/IP
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
12 mm (0.47 in.)
Mount the switches, as shown, in the vertical position only. We do not recommend horizontal mounting due to thermal considerations. Follow these guidelines. Provide 50 mm (2 in.) of space on all sides for adequate heat dissipation. Leave 100 mm (4 in.) for installation and removal if using the fiber-optic port on the bottom of the 1783-EMS08T switch.
Rockwell Automation Publication 1783-TD001C-EN-P - December 2012 13
1783-ETAP1F EtherNet/IP tap 2 copper ports 1 fiber port Fiber, single-port 200 mA @ 24V DC
1783-ETAP2F EtherNet/IP tap 1 copper port 2 fiber ports Fiber, dual-port 260 mA @ 24V DC
Tap type Current consumption, max DC power supply voltage rating Isolation voltage
3W 3W
RJ45 connector according to IEC 60603-7, 2- or 4-pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702 One 0.333.3 mm2 (2212 AWG) or two 0.331.3 mm2 (2216 AWG) solid or stranded copper wire rated at 75 C (167 F) or greater, 1.2 mm (3/64 in.) insulation max 0.60.8 Nm (57 lbin) on power connectors 1 - on power ports 2 - on communication ports None (open-style) T5 T5 T4A T4 T4 T4
Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
14
(1) The channel, that is, connectors and cable, must not exceed the allowable power budget.
60 C (140 F)
15
10V/m with 1 kHz sine-wave 80% AM from 802000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 20002700 MHz 4 kV at 5 kHz on power ports 3 kV at 5 kHz on communication ports 1 kV line-line (DM) and 2 kV line-earth (CM) on power ports 2 kV line-earth (CM) on communication ports 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz 10 ms interruption on DC supply ports
EFT/B immunity IEC 61000-4-4 Surge transient immunity IEC 61000-4-5 Conducted RF immunity IEC 61000-4-6 Voltage variation IEC 61000-4-29
UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A and B) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection n EN 60079-0; General Requirements II 3 G Ex nA IIC T5 X European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection n EN 60079-0; General Requirements II 3 G Ex nA IIC T 4 X
C-Tick Ex
KC EtherNet/IP
Korean Certification of Broadcasting and Communications Equipment, compliant with: Framework Act on Telecommunications and Radio Waves Act ODVA conformance tested to EtherNet/IP specifications
(1) When product is marked. See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
16
17
Inrush current, max AC power-supply voltage rating DC power-supply voltage rating Isolation voltage
Power consumption, max Ethernet connections DC power connections Torque, max recommended Wiring category(1) Enclosure type rating North American temp code IEC temp code
(1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
18
1783-US03T01F,1783-US05T, 1783-US08T
Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock) Temperature, surrounding air, max Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold) IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat) IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) Vibration IEC 60068-2-6 (Test Fc, Operating) Operating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock) Nonoperating shock IEC 60068-2-27 (Test Ea, Unpackaged Shock) Emissions CISPR 11 ESD immunity IEC 61000-4-2 Radiated RF immunity IEC 61000-4-3
595% noncondensing 2 g @ 10500 Hz 15 g 30 g Group 1, Class A 4 kV contact discharges 8 kV air discharges 6 kV contact discharges 8 kV air discharges
10V/m with 1 kHz sine-wave 80% AM from 802000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 1V/m with 1 kHz sine-wave 80% AM from 20002700 MHz 2 kV at 5 kHz on power ports 2 kV at 5 kHz on Ethernet ports 1 kV line-line (DM) and 2 kV line-earth (CM) on DC power ports 2 kV line-earth (CM) on shielded Ethernet port 10V rms with 1 kHz sine-wave 80% AM from 150 kHz80 MHz
EFT/B immunity IEC 61000-4-4 Surge transient immunity IEC 61000-4-5 Conducted RF immunity IEC 61000-4-6
19
1783-US03T01F, 1783-US06T01F, 1783-US05T, 1783-US08T UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E65584. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E194810. European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions European Union 94/9/EC ATEX Directive, compliant with: EN 60079-15; Potentially Explosive Atmospheres, Protection n EN 60079-0; General Requirements II 3 G Ex nA II T4 X Korean Certification of Broadcasting and Communications Equipment, compliant with: Framework Act on Telecommunications and Radio Waves Act ODVA conformance tested to EtherNet/IP specifications
c-UL-us
CE
C-Tick Ex
KC EtherNet/IP
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
P W R
3
TX
L I N K
The 1783-US06T01F and 1783-US08T switches have the same depth and height as the switches above, but they are 45 mm (1.77 in.) wide.
20
1783-US03T01F
Accessories
Small Form-factor Pluggable (SFP) Transceivers
Cat. No. Description Wavelength Core Size/ Cladding Size (micron) 50/125 62.5/125 1783-SFP100LX 100 Base-LX single-mode transceiver 1310 nm G.652 Modal Bandwidth (MHz/km) 500 500 10 km (32.81 ft) Cable Length Compatibility
1783-SFP100FX
1310 nm
2 km (6562 ft)
Stratix 5700 Stratix 8000 Stratix 8300 Stratix 5700 Stratix 8000 Stratix 8300 Stratix 6000 Stratix 5700 Stratix 8000 Stratix 8300 Stratix 6000 Stratix 5700 Stratix 8000 Stratix 8300
1783-SFP1GSX
850 nm
220 m (722 ft) 275 m (902 ft) 500 m (1640 ft) 550 m (1804 ft) 10 km (32.81 ft)
1783-SFP1GLX
1310 nm
G.652
Memory Cards
Cat. No. 1784-SD1 1783-MCF 1783-RMCF Description 1 GB industrial SD card Stratix 8000 CompactFlash card (spare) Stratix 8300 CompactFlash card (spare) Compatibility Stratix 5700 Stratix 8000 Stratix 8300
21
Ethernet Cable
Cat. No. 1585J-M8PBJM-2 1585J-M8PBJM-5 1585J-M8PBJM-10 1585J-M8CBJM-2 1585J-M8CBJM-5 1585J-M8CBJM-10 1585-C8CB-S100 1585-C8PB-S100 1585-C8PB-S300 1585-C8PB-S600 1585J-M8CC-SH Field attachable connector, IDC Unshielded Ethernet cable spool Shielded Ethernet cable spool Shielded (STP) RJ45 to RJ45 patchcord Description Unshielded (UTP) RJ45 to RJ45 patchcord Cable Length 2 m (6.56 ft) 5 m (16.41 ft) 10 m (32.81 ft) 2 m (6.56 ft) 5 m (16.41 ft) 10 m (32.81 ft) 100 m (328.08 ft) 100 m (328.08 ft) 300 m (984.25 ft) 600 m (1, 968.51 ft)
For additional Ethernet media choices, see On-Machine Connectivity Catalog, publication M117-CA001.
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource EtherNet/IP Industrial Protocol White Paper, publication ENET-WP001 Stratix 5700 Ethernet Managed Switch Installation Instructions, publication 1783-IN009 Stratix 5700 Ethernet Managed Switches User Manual, publication 1783-UM004 Stratix 8000 and 8300 Ethernet Managed Switches User Manual, publication 1783-UM003 Stratix 6000 Ethernet Managed Switch User Manual, publication 1783-UM001 Stratix 2000 Ethernet Unmanaged Switch Installation Instructions, publication 1783-IN001 Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, http://www.ab.com Description Describes how to implement services and data objects on a TCP/UDP/IP based Ethernet network. Provides details about installing and configuring the switch. Provides detailed information on configuring and managing the switches. Provides detailed information on configuring and managing the switches. Provides details about how to configure and use the switch. Provides details about installing and configuring the switch. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details.
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
22
Notes:
23
Important Information
Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this publication are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.
Allen-Bradley, Rockwell Software, Rockwell Automation, LISTEN.THINK.SOLVE., On-Machine, Stratix 2000, Stratix 5700, Stratix 6000, Stratix 8000, and Stratix 8300 are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.., Kar Plaza Merkezi E Blok Kat:6 34752 erenky, stanbul, Tel: +90 (216) 5698400
www.rockwel lautomation.com
Power, Control and Information Solutions Headquarters
Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation NV, Pegasus Park, De Kleetlaan 12a, 1831 Diegem, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846