WindObserverII Manual Issue 19
WindObserverII Manual Issue 19
WindObserverII Manual Issue 19
Ultrasonic Anemometer
User Manual
WindObserver II Anemometer
________________________________________________________________________________________________
WindObserver II
Page 2
Issue 19
Doc. No. 1390-PS-0004
August 2009
Contents
1.
2.
3.
4.
5.
FOREWORD............................................................................................6
INTRODUCTION......................................................................................6
FAST TRACK SET-UP ............................................................................6
SPECIFICATION .....................................................................................7
PRE-INSTALLATION ..............................................................................8
5.1.
5.2.
6.
INSTALLATION.....................................................................................10
6.1.
6.2.
6.3.
6.4.
Installation Guidelines..................................................................................... 10
Bench system test .......................................................................................... 11
Cabling ........................................................................................................... 11
Connections.................................................................................................... 12
Default Settings................................................................................................... 13
Connecting to a PC with a RS422 or RS485 input ............................................... 14
Networking units.................................................................................................. 15
Connecting to a PCI Unit with RS422 input.......................................................... 16
Indoor Power and Communications Interface (Part 1189-PK-021)........................ 16
PCI Electrical Power Requirements ..................................................................... 16
PCI Connector Pin and Cable assignments ......................................................... 17
Anemometer connector 15 way ........................................................................ 17
Auxiliary Analogue Outputs 9 way .................................................................... 17
DC Supply 4 way.............................................................................................. 17
RS 232 Output 9 way ....................................................................................... 18
RS422 Network In 9 way Skt ............................................................................ 18
RS422 Network Out 9 way Plg.......................................................................... 18
6.5.
Analogue connections..................................................................................... 19
Analogue Voltage Output Connections (5v or 2.5v)........................................... 19
Analogue Connections for 4-20mA output............................................................ 19
6.6.
6.7.
7.
8.
8.1.
8.2.
8.3.
8.4.
8.5.
Networking...................................................................................................... 28
Units ............................................................................................................... 29
Output rate...................................................................................................... 29
Sample Average.................................................................................................. 29
8.6.
8.7.
________________________________________________________________________________________________
WindObserver II
Page 3
Issue 19
Doc. No. 1390-PS-0004
August 2009
8.8.
8.9.
8.10.
8.11.
NMEA Format................................................................................................. 36
Analogue outputs and options......................................................................... 37
Output modes ..................................................................................................... 37
Channel outputs .................................................................................................. 37
Status ................................................................................................................. 37
Temperature ....................................................................................................... 37
Tunnel mode ....................................................................................................... 37
Scaling................................................................................................................ 37
Averaging............................................................................................................ 37
Polar mode direction wraparound ........................................................................ 38
Low wind speeds................................................................................................. 38
9.
CONFIGURING......................................................................................39
9.1.
9.2.
9.3.
9.4.
9.5.
10.
10.1.
10.2.
10.3.
10.4.
10.5.
10.6.
________________________________________________________________________________________________
WindObserver II
Page 4
Issue 19
Doc. No. 1390-PS-0004
August 2009
11.
APPENDICES........................................................................................49
11.1.
11.2.
11.3.
11.4.
________________________________________________________________________________________________
WindObserver II
Page 5
Issue 19
Doc. No. 1390-PS-0004
August 2009
1.
FOREWORD
Thank you for purchasing the WindObserver II manufactured by Gill Instruments Ltd.
The unit has no customer serviceable parts and requires no calibration or maintenance.
To achieve optimum performance we recommend that you read the whole of this manual
before proceeding with use. Do NOT remove black rubber transducer caps.
Gill products are in continuous development and therefore specifications may be subject to
change and design improvements without prior notice.
The information contained in this manual remains the property of Gill Instruments and
should not be copied or reproduced for commercial gain.
2.
INTRODUCTION
The Gill WindObserver II wind sensor is a very robust, lightweight unit with no moving
parts, outputting wind speed and direction. The units of wind speed, output rate and
formats are all user selectable.
The WindObserver II is available with or without de-icing heating (recommended if icing
is likely), and with or without analogue outputs.
The WindObserver II can be used in conjunction with a PC, data logger or other device,
provided it is compatible with the RS422 output or the analogue outputs. Multiple units
can be networked if required.
Alternatively, the WindObserver II is designed to connect directly to the Gill WindDisplay
unit to provide a complete wind speed direction system without any configuration required
by the user.
The output message format can be configured in Polar, UV (2-axis), NMEA (0183
Version 3), Tunnel formats, and as either a Continuous output or Polled (requested by host
system), detailed in full in Section 8 Message Formats & Options.
WindObserver II may be configured using WindCom software which is available, free of
charge, from the Gill website www.gill.co.uk, or by using standard communications
software on a PC. This is explained in Section 9 Configuring.
3.
If you are in a hurry to try out the WindObserver II, are familiar with Gill equipment, and
coupling to a PC using RS422, go to the following sections:
Section 6 Installation
Section 8 Message Formats & Options
Section 9 Configuring
After you have successfully set up the WindObserver II, we strongly advise that you then
go back and read the rest of the manual to ensure that you get the best results from the
WindObserver II.
________________________________________________________________________________________________
WindObserver II
Page 6
Issue 19
Doc. No. 1390-PS-0004
August 2009
4.
SPECIFICATION
Measurement
Output
Parameters
Units
Averaging
Wind Speed
Range
Accuracy
Resolution
Offset
Direction
Range
Accuracy
Resolution
Sonic Temperature Output
Range
Anemometer Status
Starting Threshold
Dead Band Wind Direction
Power Requirement
Anemometer only
Heating - Optional
Digital Output
Communication
Baud rates
Formats
Analogue Output - Optional
Quantity
Scale
Type
V output resistance
4-20mA loading
Dimensions
Size
Weight
Materials
External Construction
Environmental
Moisture protection
Operating temperature
Humidity
Precipitation
EMC
Icing
Standards
Site Calibration
1, 2, 4, 5, 8, 10Hz
UV, Polar, NMEA, Tunnel
m/s, Knots, MPH, KPH ft/min
Flexible 1-3600 seconds
0 - 65m/s (0-145mph)
2%@12m/s
0.01m/s
0.01m/s
0 - 359
2
1
-40C to + 70C
Supplied as part of standard message
0.01 m/s
None
9-30 V DC (40mA @ 12VDC), reverse voltage protected
Allow 3A @ 22v to 30v (max) AC rms or DC
RS422, full duplex, network facility
1200, 2400, 4800, 9600, 19200, 38400
8 data, odd, even or no parity
3 (speed, direction, status, SOS or Sonic Temperature)
Multiples of 10m/s up to 70m/s
2.5V, 0-5V or 4-20mA
60 Ohms
10-300 Ohms
405mm x 210mm
1.5kg
Stainless Steel 316
IP66 (NEMA4X)
-55C to +70C (heated version)
0% to 100% RH
300mm/hr
BS EN 50081-1: 1992 (Emissions class B)
BS EN 50082-2: 1992 (Immunity)
FCC class A
MILSTD810E Method 521.1 Procedure 1
Traceable to UK national standards
None required. (See Section 10.6 Zero Wind Check)
________________________________________________________________________________________________
WindObserver II
Page 7
Issue 19
Doc. No. 1390-PS-0004
August 2009
5.
PRE-INSTALLATION
5.1.
Equipment supplied
or
or
or
and
and
and
and
5.2.
Installation requirements
________________________________________________________________________________________________
WindObserver II
Page 8
Issue 19
Doc. No. 1390-PS-0004
August 2009
Mounting Bracket
A mounting bracket is required (not provided) which will attach to the WindObserver II
via the four tapped holes in the base of the unit. Always ensure that the gasket supplied is
fitted to the base of the anemometer.
It is important that the gasket supplied forms a watertight seal on the base of the
anemometer.
In the event that the mounting bracket supplied by the customer is not flat or does not
form complete support for the anemometer base; the customer must fit a mounting ring as
shown in Figure 2.
See Section 6.7 for mounting details.
________________________________________________________________________________________________
WindObserver II
Page 9
Issue 19
Doc. No. 1390-PS-0004
August 2009
6.
INSTALLATION
Do NOT remove the black rubber transducer caps. Take care not to knock
the four Transducer arms. All the time the WindObserver II is not in its final
location, it should be protected from damage by keeping it in the original
packaging as long as possible, treating it as a delicate instrument.
If an Intrinsically Safe (IS) device is required, the I.S. WindObserver must be
used - the WindObserver II is NOT an IS device.
Warranty is void if the unit case is removed.
6.1.
Installation Guidelines
The WindObserver II has been designed to meet and exceed the stringent standards listed
in its specification. Operating in diverse environments all over the world, WindObserver II
requires no calibration or adjustment whatsoever.
As with any sophisticated electronics, good engineering practice should be followed to
ensure correct operation.
Always check the installation to ensure the WindObserver II is not affected by
other equipment operating locally, which may not conform to current standards,
e.g. radio/radar transmitters, boat engines, generators etc.
Guidelines
Avoid mounting in the plane of any radar scanner a vertical separation of
at least 2m should be achieved.
Radio transmitting antennas, the following minimum separations (all round)
are suggested
VHF IMM 1m
MF/HF 5m
Satcom 5m (avoid likely lines of sight)
Ensure the product is correctly earthed in accordance with this manual
Use cables recommended by Gill, keeping the length below the maximum allowed
(See Section 6.3) Where the cables are cut and re-connected (junction boxes, plugs
and sockets) the cable screen integrity must be maintained, to prevent the EMC
performance being compromised.
Earth loops should not be created earth the system in accordance with the
installation guidelines. (See Section 6.4)
Ensure the power supply operates to the WindObserver II specification at all times.
Avoid turbulence caused by surrounding structures that will affect the accuracy of the
WindObserver II such as trees, masts and buildings. The World Meteorological
Organisation makes the following recommendation:
The standard exposure of wind instruments over level open terrain is 10m above
the ground. Open terrain is defined as an area where the distance between the
sensor and any obstruction is at least 10 times the height of the obstruction.
When installing the unit degrease the unit and hold with lint free gloves to reduce the
build up of deposits.
________________________________________________________________________________________________
WindObserver II
Page 10
Issue 19
Doc. No. 1390-PS-0004
August 2009
6.2.
Note: Prior to physically mounting the WindObserver II in its final location, we strongly
recommend that a bench system test be carried out to confirm the system is configured
correctly, is fully functional and electrically compatible with the selected host system and
cabling (preferably utilising the final cable length). The required data format, units,
output rate, and other options should also all be configured at this stage. If an Integrity
Check Chamber (ICC) has been purchased refer to Section 10.6.
6.3.
Cabling
Cable type
A RS422 compatible cable should be used, with the number of twisted pairs matching the
application. If both the (optional) Heating and Analogue outputs are utilised, then a 9 pair
cable is required.
Generic description Twisted pairs with drain wire, screened with aluminised tape,
with an overall PVC sheath. Wire size 7/0.2mm (24 AWG)
The table shows some suitable manufacturers references; other manufactures equivalents
can be used.
Table 1
Belden
Batt electronics
No. of pairs Gill ref.
ref.
ref.
2
9729
3
026-02660
9730
91030
4
026-03156
9728
91199
9
026-02663
8774
91009
Cable length
The typical maximum length at 9600 baud is 1km (3200ft), using the recommended cable.
If any problems of data corruption are experienced (due to, for example, a high local
electrical noise level), then a lower baud rate should be used. Alternatively, a thicker or
higher specification cable can be tried. If a heated unit is used on longer cables than
supplied, consideration should be given to powering the heater using lower gauge wire or
paralleling wires to reduce volt drops.
Cabling and junction box
The WindObserver II unit is fitted with a flying 9 pair cable attached (2m or 10m long).
This must be terminated in a suitable terminal box to IP66 or better, fitted with glands to
prevent moisture ingress.
The cable type from the terminal box to the host system must be as specified above. If any
cable is likely to be exposed to mechanical damage, it must be enclosed in a suitable
conduit or cable tray. The cable must be securely fixed with cable clamps or equivalent at
regular intervals such that the WindObserver cable gland does not support the cable
weight.
The gland area at the base of the WindObserver II should not be directly exposed to
moisture, as whilst the gland is sealed when mated, the anemometer is vented to air at the
base to avoid pressure build up. If an IP66 rating is essential or the unit is mounted other
than right way up use the gasket provided in the mounting kit.
________________________________________________________________________________________________
WindObserver II
Page 11
Issue 19
Doc. No. 1390-PS-0004
August 2009
6.4.
Connections
Important
Do NOT join any of the cores of the cable together. Joining cores
could damage the unit permanently. Any cores not used should be isolated.
Do NOT connect the units 0V, heating ve, analogue output 0V or digital 0V to the
screen or earth.
The screens of each pair are joined together inside the anemometer - these should be
joined to the cable screen(s) of any further cable run. Avoid long grounding loops. Digital
OV should be used in conjunction with RS422 TX RX lines in order to improve noise
immunity. Each pair in the cable is labelled with its pair number.
Table 2
Conductor colour
Designation
Pair 1
green
RS422_TXB (+)
black
RS422_TXA (-)
Pair 2
white
RS422_RXB (+)
black
RS422_RXA (-)
Pair 3
red
Supply V+
black
Supply VPair 4
blue
Digital 0v
black
Analogue 0v
Pair 5
yellow
Heater + *1
black
Heater *1
Pair 6
brown
Analogue Ch 3 output *2
black
Analogue 0v *2
Pair 7
orange
Not used (isolate) *2
black
Not used (isolate) *2
Pair 8
white
Analogue Ch 1 output *2
red
Analogue Ch 2 output *2
Pair 9
green
Not used (isolate) *2
red
Not used (isolate) *2
Screens
Chassis ground
*1 and 2 Note may not be functional - check model number and options fitted.
*2 NOTE Analogue connections change on units from serial number 901001.
Earthing or grounding
To ensure correct operation, and for maximum protection against lightning, the
anemometer MUST be correctly earthed (grounded) via its mountings. Inadequate
Earthing will degrade anemometer performance, particularly in the presence of radio
frequency interference.
See Fig 1 Suggested mounting bracket and Earthing (grounding) arrangements
The unit MUST be connected to an appropriate grounding point with a minimum of 6mm
copper wire, via the M5 base screws. The cable screens must be joined with any cable
screen continuing from the units cable via a junction box. The primary earth for the
anemometer must be provided via the base screws and not via the cable screens.
________________________________________________________________________________________________
WindObserver II
Page 12
Issue 19
Doc. No. 1390-PS-0004
August 2009
Default Settings
The factory default settings are:
Non - heated units
A0 B3 C1 E1 F1 G0000 J1 K1 L1 M2 NA O1 P1 T1 U1 V1 X1 Y1 Z1
Heated units
A0 B3 C1 E1 F1 G0000 H1 J1 K1 L1 M2 NA O1 P1 T1 U1 V1 X1 Y1 Z1
Note that Heating (H command) is not enabled as a default condition. If heating is
required enabled then the H command must be set for H2.
See Section 9 Configuring for further details
________________________________________________________________________________________________
WindObserver II
Page 13
Issue 19
Doc. No. 1390-PS-0004
August 2009
WindObserver II
9 pair cable
PC with RS422
or RS485 input
Cable-43toor64
Cable
Twistedpairs
Pairs
twisted
Signal names
Pair
no
Colour
TXB (+)
TXA (-)
green
black
RXB (+)
RXA (-)
RXB (+)
RXA (-)
white
black
TXB (+)
TXA (-)
Digital OV
blue
CONNECTED INTERNALLY
Supply V+
Supply V-
Heater + *
Heater - *
Signal names
Signal Ground
Screen and
drain wires
Ground (Earth)
red
black
DC Power
+
supply 9-30V
see section 6.6
yellow
black
+
-
Heated power
supply
see section 6.6
________________________________________________________________________________________________
WindObserver II
Page 14
Issue 19
Doc. No. 1390-PS-0004
August 2009
Networking units
Before coupling units into a network:
Each device must be configured with a unique Unit Identifier (letter A to Z)
however in multi drop systems it could be advised to avoid using letters A-F,
KMN and P as they could appear in the data string.
Unit must be set for half duplex mode (E2 setting) see Para 8.3).
It must be configured to a tri-state polled mode M3 or M4 .
See also Section 9 - Configuring
WindObserver II
9 pair cable
PC with RS485
card
Signal names
Pair
no
Colour
TXB (+)
RXB (+)
1
2
green
white
TXA (-)
RXA (-)
1
2
black
black
Digital OV
blue
CONNECTED INTERNALLY
Supply V+
Supply V-
Heater +
Heater -
Cable
Cable 3- 2toor4 3
Twisted
twisted pairs
Pairs
Signal names
.. ..
.
T / RXB (+)
T / RXA (-)
Signal Ground
Screen and
drain wires
Ground (Earth)
red
black
DC Power
+
supply 9-30V
see section 6.6
yellow
black
+
-
Heated power
supply
see section 6.6
To Next Unit
Note: Each unit in the network will require its own power supplies.
Please refer to section 8.3.
________________________________________________________________________________________________
WindObserver II
Page 15
Issue 19
Doc. No. 1390-PS-0004
August 2009
PCI
15 Way D Type
Connector
Signal Names
Signal names
TXB(+)
TXA()
Cable Pair
Pair 1
Pair 1
Colour
RXB(+)
RXA(-)
Pair 2
Pair 2
White
Black
3
10
Digital 0v
Pair 4
Blue
POWER V+
Pair 3
Red
POWER V+
POWER 0V
Pair 3
Black
11
POWER 0V
Green
Black
Pin Nos.
2
9
RXB(+)
RXA()
TXB(+)
TXA(-)
Signal Ground
Externally accessible
Internally accessible
________________________________________________________________________________________________
WindObserver II
Page 16
Issue 19
Doc. No. 1390-PS-0004
August 2009
DC Supply 4 way
Pin
Designation
1
Interface V+
2
Interface V3
Anemometer V4
Anemometer V+
________________________________________________________________________________________________
WindObserver II
Page 17
Issue 19
Doc. No. 1390-PS-0004
August 2009
________________________________________________________________________________________________
WindObserver II
Page 18
Issue 19
Doc. No. 1390-PS-0004
August 2009
6.5.
Analogue connections
When using the analogue outputs it is advisable to use a low pass filter to remove any high
frequency noise present.
The analogue signals can be susceptible to external interference if unprotected. The
anemometer cable has individual screens covering each channels signal wires. The
continuing cable connected to the anemometer must be of equal or greater cross sectional
area as the anemometer cable and must be individually screened or screened pairs.
Note that connections can also be made to a PC or other device as described in the
preceding section.
REFER TO SECTION 9.5 the T command selects Voltage or Current Output on Channels
1-3.
Analogue Voltage Output Connections (5v or 2.5v)
Anemometer
+
V
0v return,
Pair 6 Black or
Pair 4 Black
Anemometer
0v return,
Pair 6 Black or
Pair 4 Black
300 max
________________________________________________________________________________________________
WindObserver II
Page 19
Issue 19
Doc. No. 1390-PS-0004
August 2009
6.6.
Power supplies
9 to 30v DC
60mA max. 50mA average
________________________________________________________________________________________________
WindObserver II
Page 20
Issue 19
Doc. No. 1390-PS-0004
August 2009
6.7.
Mechanical installation
Do NOT remove the black rubber transducer caps. Take care not to knock
the four Transducer arms.
Before installing, a bench system test is recommended.
All the time the WindObserver II is not in its final location, it should be
protected from damage by keeping it in the original packaging as long as
possible, treating it as a delicate instrument.
When installing the unit handle with lint free gloves and degrease the unit to
reduce the build up of deposits.
Location
It is important to ensure that the WindObserver II is mounted in a position clear of any
structure, which may obstruct the airflow or induce turbulence.
Do NOT mount the WindObserver II in close proximity of high-powered radar or radio
transmitters. A site survey may be required if there is any doubt about the strength of
external electrical noise. (See Section 6.1)
Orientation
Normally the WindObserver II is mounted vertically with the cable exit at the bottom.
Alternatively, the unit may be mounted in any orientation, but note that if the unit is
mounted with the cable uppermost, the gasket provided in the mounting kit must be used.
Mounting bracket
A suggested mounting bracket is shown in Fig 1 below.
It is recommended that the WindObserver II mounting bracket be manufactured from
stainless steel 316, to prevent possible galvanic corrosion.
It is also recommended that the supplied gasket be always fitted to ensure IP66 rating and
to prevent galvanic corrosion if the mounting bracket is not manufactured from stainless
steel 316.
Stainless steel 316 fixings must be used.
________________________________________________________________________________________________
WindObserver II
Page 21
Issue 19
Doc. No. 1390-PS-0004
August 2009
________________________________________________________________________________________________
WindObserver II
Page 22
Issue 19
Doc. No. 1390-PS-0004
August 2009
Alignment
The anemometer should be set to point North (or to another known reference direction),
using the North Spar, which can be identified from the red dot alignment indicator on the
base of the instrument. See Figure 2a.
If the unit is used in a tunnel, (and the Tunnel format is used), the unit would normally be
aligned with the N S axis in the horizontal plane.
Figure 2a North marker and UV polarity definition (UV format) and Mounting Ring
Red Dot
SEE FIG.
DEFINITION
________________________________________________________________________________________________
WindObserver II
Page 23
Issue 19
Doc. No. 1390-PS-0004
August 2009
2-metre cable
________________________________________________________________________________________________
WindObserver II
Page 24
Issue 19
Doc. No. 1390-PS-0004
August 2009
7.
The WindObserver II is designed to link directly to the Gill WindDisplay unit to provide a
complete wind speed and direction system.
When coupled to a WindDisplay, the WindObserver II can be used as supplied,
however if a fault occurs, the WindDisplay may lock into the last valid reading. Reconfiguring the Wind Observer to Fixed Field Output (O2) will ensure that any fault
is flagged on the WindDisplay.
After coupling to a WindDisplay, the Wind Speed units and the Averaging period can be
selected using the WindDisplay controls. See the WindDisplay User Manual.
Note that although the WindDisplay can display wind speed in various units, these are
calculated within the WindDisplay. The data coming to the WindDisplay must be in
metres/sec (the factory default output setting).
Figure 3 WindDisplay
The WindDisplay has been designed to provide anemometer power (approximately 15V
@40mA).
If the WindObserver II has a de-icing heater fitted, this will need a separate power supply.
(See Section 6.6 ).
NOTE:- If the WindDisplay is configured for NMEA mode then the WindObserver
II must also be configured for NMEA mode and 4800-baud operation (configuration
settings M5 and B2).
________________________________________________________________________________________________
WindObserver II
Page 25
Issue 19
Doc. No. 1390-PS-0004
August 2009
WindObserver II
9 pair cable
Pair
Signal names
Colour
no.
TXB (+)
green
1
TXA ()
black
CONNECTED INTERNALLY
Supply V+
Supply V-
Heater + *
Heater - *
WindDisplay
Cable 2 or 3
twisted pairs
Screen and
drain wires
Signal
names
TXD +
TXD
Terminal
nos.
RS422+
RS422-
Ground (Earth)
red
black
+
O
yellow
black
+
-
2
1
Heater power
supply
See Section 6.6
* If fitted
________________________________________________________________________________________________
WindObserver II
Page 26
Issue 19
Doc. No. 1390-PS-0004
August 2009
8.
On first applying power to the WindObserver II, it will be in Measurement Mode, and it
will output wind measurement information in one of eight formats as described below.
Setting the output format, units, other parameters, options and the communication settings
are all carried out in the alternative Configuration Mode.
See Section 9 CONFIGURING for details of how this is done.
The factory default settings are shown here in bold, and for convenience some
Configuration codes (as used to set the configuration) are shown in blue boxes.
For example M3 .
8.1.
The wind speed measurements can be output in one of the following formats:
UV, Polar, Customer formats (NMEA and Tunnel).
8.2.
Output formats
The UV and Polar wind speed parameters are output in either ASCII or binary.
These parameters can be transmitted continuously or polled from the user.
Polar is also available in continuous NMEA format.
Output Formats Table
Output format
Output
Continuous
ASCII
UV
Polled
Continuous
ASCII Polar
Polled
ASCII Tunnel
Continuous
ASCII Tunnel
Polled
NMEA
Continuous
Binary Tunnel
Continuous
Binary UV short Continuous
Binary Polar
Continuous
Tri-state o/p
No
Yes
No
Yes
No
Yes
No
No
No
No
Configuration code
M1
M3
M2
M4
M12
M13
M5
M6
M7
M8
________________________________________________________________________________________________
WindObserver II
Page 27
Issue 19
Doc. No. 1390-PS-0004
August 2009
8.3.
Networking
RS485 I/F
(USB)
SWITCH
HYPER-TERMINAL
B (Full-D)
WObsII
RS422 I/F
(USB)
b (4-wire)
One PC (with two USB ports) can be used for both Terminals, although two may be less
confusing.
Note: Power must not be disconnected from the anemometer throughout this procedure.
2) Assuming the unit is set for Full Duplex, connect 9-way at [b] disconnect 9-way at
[a]. Set Switch to position [b] (4 wire).
3) On Terminal B, enter CONFIGURATION MODE. Set Half Duplex (E2). The
CONFIRM> prompt will appear.
4) Disconnect 9-way [b] and connect 9-way [a]. Set Switch to position [a] (2 wire).
5) On Terminal A, type E <ENTER> to confirm.
6) The unit should now be configured in Half Duplex mode.
Configuring WindObserver II for Full Duplex Operation.
1) Assuming the unit is set for Half Duplex, disconnect 9-way [b] and connect 9-way
[a]. Set Switch to position [a] (2 wire).
2) On Terminal A, type E1 to select Full Duplex. The CONFIRM> prompt will
appear.
3) Disconnect 9-way [a] and connect 9-way [b]. Set Switch to position [b] (4 wire).
4) On Terminal B type E <ENTER> to confirm.
________________________________________________________________________________________________
WindObserver II
Page 28
Issue 19
Doc. No. 1390-PS-0004
August 2009
8.4.
Units
8.5.
Output rate
The output frequency can be set between 1 and 10 per second. The wind speed is sampled
every 25ms, each axis being sampled sequentially. The following Table lists the possible
outputs per second and the corresponding number of averaged samples. A 25ms sample
period is used to process and output the results.
Outputs per Second Sample Average
1
39
2
19
4
9
5
7
8
4
10
3
8.6.
The Averaging Period can be set from zero to 3600 secs. (1 hour). The default setting is
zero. When averaging is enabled, data is output at a rate determined by the averaging
period. The data is an average of valid data collected during the averaging period. If G is
set to zero then averaging settings will be disabled.
8.7.
Options
________________________________________________________________________________________________
WindObserver II
Page 29
Issue 19
Doc. No. 1390-PS-0004
August 2009
________________________________________________________________________________________________
WindObserver II
Page 30
Issue 19
Doc. No. 1390-PS-0004
August 2009
8.8.
ASCII UV format
U axis wind speed
Units
<STX>A,+000.04,-000.02,M,+345.01,+022.36,00,<ETX>25
Start of
string
Unit
identification
Speed of
sound
Temperature
Status
End of
string
Check
sum
Where
U axis wind speed
V axis wind speed
Units
Units
Metres per second (m/s)
Knots (knots)
Miles per hour (MPH)
Kilometres per hour (kph)
Feet per minute (fpm)
Start of string
Unit identification
Speed of sound
Temperature
ASCII value 2
Letter A Z (default A)
In metres per second (if enabled)
Sonic temperature in degrees C (if enabled)
Status
Value
0
60
Any other value
End of string
Check sum
ASCII value 3
Exclusive OR of all characters between Start of String
and End of String reported as ASCII hex.
Status
OK
Heating enabled and OK if enabled
Warning or fault condition
- see Section 10.5
________________________________________________________________________________________________
WindObserver II
Page 31
Issue 19
Doc. No. 1390-PS-0004
August 2009
Wind speed
Units
<STX>A,121,000.08,M,+344.66,+021.76,00,<ETX>06
Start of
string
Unit
identification
Speed of
sound
Temperature
Status
End of
string
Check
sum
Where
Wind direction
Wind speed
Command
A .. Z
WindObserver response
Wind speed output generated
(None)
(None)
&
A .. Z (as configured)
Where:
<STX>
WindObserver node address
U axis
U axis
U axis
speed
=
=
=
=
U axis
polarity
Units
Status
Check
sum
________________________________________________________________________________________________
WindObserver II
Page 33
Issue 19
Doc. No. 1390-PS-0004
August 2009
8.9.
Binary UV format
U axis wind speed
Units
Speed of sound
Temperature
Status
Where
U axis wind speed
V axis wind speed
Units
Start of string
Speed of sound
Temperature
Status
Units
Metres per second (m/s)
Knots (knots)
Miles per hour (MPH)
Kilometres per hour (kph)
Feet per minute (fpm)
Status
OK
Heating enabled and OK
Warning or fault condition
- see Section 10.5
Wind direction
Units
Speed of sound
Temperature
Status
Where
Wind direction
Wind speed
All other parameters
________________________________________________________________________________________________
WindObserver II
Page 34
Issue 19
Doc. No. 1390-PS-0004
August 2009
Direction
Units
Status
Other parameters
________________________________________________________________________________________________
WindObserver II
Page 35
Issue 19
Doc. No. 1390-PS-0004
August 2009
Wind direction
Wind speed
Units
Checksum
Delimiter
Start of string
Instrument
type
Wind
measurement
Status
Check
sum
Where
Wind direction
Wind speed
Units
M
N
P
K
F
Start of string
Instrument type
Wind measurement
Status
$
IIMWV
R
Relative wind measurement
A
Acceptable measurement
V
Void measurement
Exclusive OR of all characters between $ and *
reported as ASCII hex.
Check sum
________________________________________________________________________________________________
WindObserver II
Page 36
Issue 19
Doc. No. 1390-PS-0004
August 2009
Channel 1
U
Magnitude
Magnitude
U Speed
U Speed
U Speed
Channel 2
V
Direction
Direction
U direction
U Direction
U Direction
Channel 3
Status or Temperature
Status
If channel 3 is configured for Status, the output will be 0v (or 4mA) if the unit is in an OK
condition. In a fault condition, error code 01, 02, or 04, the output will be +5v (or 0mA).
See Section 10.5 for the list of Error Codes.
Temperature
If channel 3 is configured for Temperature, it reports the temperature if it is between 40
and +70C, scaled from +0.7V to +5V (6.25mA to 20mA). Temperatures outside this
range are reported as errors by setting the output to 0V (4mA).
Tunnel mode
In Tunnel mode, Channel 1 represents the Wind Speed along the U Axis, Channel 2 gives
the direction of the wind along the U axis, where a U vector (=wind from the N
direction) is represented by 0v (or 4mA), and a +U vector (=wind from the S direction)
by 5v (or 20mA).
Scaling
All analogue outputs are in m/s irrespective of the digital units of measurement setting and
can be scaled to have a full-scale deflection of 10 to 70 units using the Z command.
In Polar mode the sign should be ignored. Only the + sign is effective.
In all cases zero Wind Speed is represented by 0V or 4mA.
Averaging
Analogue Outputs are not averaged when using the G command.
________________________________________________________________________________________________
WindObserver II
Page 37
Issue 19
Doc. No. 1390-PS-0004
August 2009
Standard
Wraparound
Standard
Wraparound
0
2.5
5.0
N/a
0
1.67
3.33
5.0
4.00
12.00
20.00
N/a
4.00
9.33
14.67
20.00
Channel 1
(Wind Speed)
Variable 4 to 20mA
(value depends on
Output scaling)
Variable close to
4mA.
Channel 2
(Wind Direction)
Variable 4 to 20mA
(Value depends on
Output scaling)
Outputs last known
good/valid current
reading until wind
increases above
0.05m/s.
Outputs last known
good/valid current
reading until fault
clears.
Channel 3
(Status)
4mA
(Unit functioning
correctly)
4mA
(Unit functioning
correctly)
0mA
(Failure code present)
________________________________________________________________________________________________
WindObserver II
Page 38
Issue 19
Doc. No. 1390-PS-0004
August 2009
9.
CONFIGURING
WindCom may be used to configure WindObserver II. This is an easy to use menu-driven
package, available as a free download at www.gill.co.uk.
Alternatively, you may use terminal emulator software such as HyperTerminal or
Terminal.
9.1.
9.2.
9.3.
________________________________________________________________________________________________
WindObserver II
Page 39
Issue 19
Doc. No. 1390-PS-0004
August 2009
If in Polled mode,
?
Enables poll
N
Polls anemometer (where N is the Unit identifier entered as upper-case)
The anemometer replies with a single set of wind measurements
&
Anemometer replies with Unit identifier
!
Disables poll
Note:- If the unit is in Polled Mode it is always best to interrogate the unit for data with a
? before the poll identifier to cater for the event that the power has been switched off or
power interrupted.
If used in a multi drop system then it is recommended that Unit Identifiers A, B, C, D, E,
F, K, M, N and P are not used.
9.4.
We strongly recommend that, as a standard procedure, you use this command ( D3 ) prior
to, and after, changing any settings. It shows the current settings for all the alterable
settings. We suggest you note down your settings, so that you can easily return to them.
Type * Enters Configuration Mode (from Continuous mode)
Or
Type *N
configuration settings.
The factory default settings for a heated unit are: A0 B3 C1 E1 F1 G0000 H1 J1 K1 L1 M2 NA O1 P1 T1 U1 V1 X1 Y1 Z1
How to change these settings is explained in the following sections.
To return to Measurement mode
9.5.
Changing settings
To change a setting, first go into Configuration mode and then refer to the sections below.
Enter the Configuration code of the new setting required, followed by ENTER .
If successful, the new setting will be echoed back as a message by the WindObserver II.
For example, to change the message format to NMEA, Type M5 and press ENTER .
The WindObserver II will reply with M5 . When the unit is returned to the Measurement
mode Type Q and press ENTER , it will be in NMEA format.
Note: The factory-set (default) settings are shown in bold in the following sections.
________________________________________________________________________________________________
WindObserver II
Page 40
Issue 19
Doc. No. 1390-PS-0004
August 2009
9.6.
Configuration Settings
Configuration code
Disable both
Report SOS
Report Sonic temperature
Report SOS and Sonic temperature
A0
A1
A2
A3
Configuration code
B1
B2
B3
B4
B5
B6
B7
To change the Baud rate when using HyperTerminal: Eg. If set to B3 (9600 baud) and it is required to set to Baud rate to B2 (4800 baud).
Type * to enter Configuration Mode.
Type B 2 and press ENTER, (Do not type any further commands at this stage).
Close the 9600 Baud HyperTerminal connection.
Open HyperTerminal and set the new connection Baud Rate to 4800 baud.
Type B and press ENTER, the letter B will be shown followed by B2
Type Q and press ENTER, data will scroll at the new baud rate.
C1
C2
________________________________________________________________________________________________
WindObserver II
Page 41
Issue 19
Doc. No. 1390-PS-0004
August 2009
Configuration code
F1
F2
F3
________________________________________________________________________________________________
WindObserver II
Page 42
Issue 19
Doc. No. 1390-PS-0004
August 2009
Configuration code
K1
K2
Configuration code
L1
L2
Configuration code
M1
M2
M3
M4
M5
M6
M7
M8
M12
M13
Options
Command
A -(A to Z)
Node Address
N<A>
If used in a multi-drop system then it is recommended that IDs A to F and K, M, N and P
are not used, as these characters can be present in the data string.
________________________________________________________________________________________________
WindObserver II
Page 43
Issue 19
Doc. No. 1390-PS-0004
August 2009
Configuration code
O1
O2
NMEA
CSV data changing to error status code
condition.
$IIMWV,191,R,000.55,M,A*19
$IIMWV,,R,,M,V*29
Fixed Field data changing to error status
code condition.
$IIMWV,191,R,000.55,M,A*19
$IIMWV,999,R,999.99,M,V*07
10
P1
P3
P2
P4
P5
P6
Q- Measurement Mode
See Section 9.2.
Tx - Analogue Output Voltage or Current settings (if fitted)
Setting
Configuration code
Voltage (0 to 5V)
Voltage (2.5V to +2.5V)
Current (4-20mA)
Ux Digital Output Units
Units
metres/sec
(m/s)
Configuration
U1
code
Vx- Vertical Output Padding
Setting
Disable vertical output padding
Enable vertical output padding
T1
T2
T3
knots
(knots)
miles / hour
(MPH)
kilometre/hour
(kph)
feet / minute
(fpm)
U2
U3
U4
U5
Configuration code
V1
V2
________________________________________________________________________________________________
WindObserver II
Page 44
Issue 19
Doc. No. 1390-PS-0004
August 2009
Notes
Configuration
code
X1
X2
X3
Align @ 45 from
North
X4
Figure 4 shows the polarity of U and V if the wind components along the U and V axis are
blowing in the direction of the respective arrows.
-U
N
-V
+V
S
+U
Figure 4 UV Polarity
Yx Analogue Output, Channel 3 (if fitted).
Setting
Configuration code
Status
Temperature
Y1
Y2
10
20
30
40
50
60
70
Z1
Z2
Z3
Z4
Z5
Z6
Z7
________________________________________________________________________________________________
WindObserver II
Page 45
Issue 19
Doc. No. 1390-PS-0004
August 2009
10.2. Servicing
There are no moving parts or user-serviceable parts requiring routine maintenance.
Opening the unit or breaking the security seal will void the warranty and the calibration.
In the event of failure, prior to returning the unit to your authorised Gill distributor, it is
recommended that:
All cables and connectors are checked for continuity, bad contacts, corrosion etc.
A bench test is carried out as described in Section 10.6.
Contact your supplier for advice if failure persists.
10.3. Fault-finding
Symptom
No output
Corrupted output
One way
communication
Failed / Incorrect
WindObserver II
output, data
invalid flag
Solution
Check DC power to WindObserver II, cable and connections.
Check comms settings of WindObserver II (as detailed in Section
9) and host system match, including correct Com port.
Check unit is in Continuous mode.
Check that in-line communication devices are wired correctly.
NOTE: It is usual for Anemometer TX + to be connected to
converter device RX +.
Check comms settings of WindObserver II and host system
match.
Try a slower baud rate.
Check cable lengths and type of cable.
Check wiring is in accordance with the manual.
Check that transducer path is not blocked.
________________________________________________________________________________________________
WindObserver II
Page 46
Issue 19
Doc. No. 1390-PS-0004
August 2009
Status
OK
OK and heating
enabled
OK
Axis 1 failed
Axis 2 failed
Axis 1 and 2 failed
NVM error
ROM error
System gain at max.
Marginal system gain
Measurement average
building.
Heating current tripped
or electronic failure,
Heater Thermistor open
circuit
Heating element open
circuit
NMEA data Void
Condition
Sufficient samples in average period
Sufficient samples in average period
NMEA data Acceptable
Insufficient samples in average period on U axis
Insufficient samples in average period on V axis
Insufficient samples in average period on both axes
NVM checksum failed, data could be uncalibrated.
ROM checksum failed, data could be uncalibrated.
Inaccurate data likely
Data valid, but marginal operation
Data valid but warns that average period not reached
when averaging used.
Valid data still output
Valid data still output.
Valid data still output, Heater Element or Heater
PSU has dropped out/failed
Invalid data output
________________________________________________________________________________________________
WindObserver II
Page 48
Issue 19
Doc. No. 1390-PS-0004
August 2009
11. APPENDICES
11.1. Glossary & Abbreviations
Item
CAL
CR
CRLF
CSV
ENG
ESC
ETX
FAC
fpm
GND
HEX
I/P
IP66
KPH
LF
m/s
MAG
MAX
MPH
NEMA
NMEA 0183
(version 3)
No:
NVM
O/P
PC
PCB
POR
PROCOMM
ROM
RS232
Meaning
Calibration
Carriage Return
Carriage Return Line Feed
Comma Separated Variable
Engineering
ESCape key on keyboard used to stop any process that is being
executed
End of string character
Factory
Feet per minute
GrouND
HEXadecimal
InPut
Protection Classification
Kilometres per Hour
Line Feed
Metres per second
MAGnitude - scalar reference to wind speed
MAXimum
Miles per Hour
National Electrical Manufacturers Association
National Marine Electronics Association standard for interfacing
marine electronic navigational devices
Number
Non-Volatile Memory
Output
IBM compatible Personal Computer
Printed Circuit Board
Power On Reset
Terminal emulator software package
Read Only Memory
Communications standard
________________________________________________________________________________________________
WindObserver II
Page 49
Issue 19
Doc. No. 1390-PS-0004
August 2009
Item
RS422
RS485
RTS
RX
RXD
S/W
SOS
SEC
STX
TERM
TX
TXD
+VE
-VE
WindCom
WRT
Meaning
Communications standard
Communications standard
Request To Send
Receive
Received Data
SoftWare
Speed Of Sound
SECond
Start of string character
TERMinal
Transmit
Transmitted Data
Positive
Negative
Gill software used to configure WindObserver II
With Respect To
11.2. Guarantee
For terms of guarantee contact your supplier.
Warranty is void if the green security seal covering base nuts is damaged or broken, or the
transducer caps have been damaged.
________________________________________________________________________________________________
WindObserver II
Page 50
Issue 19
Doc. No. 1390-PS-0004
August 2009
________________________________________________________________________________________________
WindObserver II
Page 51
Issue 19
Doc. No. 1390-PS-0004
August 2009
to which this declaration relates, are in conformity with the protection requirements of Council Directive
89/336/EEC on the approximation of the laws relating to electromagnetic compatibility.
This Declaration of Conformity is based upon compliance of the product with the following harmonized
standards:
EN60945:2002
EN61326:2006
Emissions
Immunity
Using
Using
EN60945
EN61000-4-2 to EN61000-4-5
EN61000-4-6 (Excluding 150kHz to 200kHz Conducted Immunity).
EN61000-4-11
Signed by
16/10/2008
Place of issue:
________________________________________________________________________________________________
WindObserver II
Page 52
Issue 19
Doc. No. 1390-PS-0004
August 2009