9903
9903
, LTD
The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
SME300000041
TABLE OF CONTENTS
INSTRUCTION FOR USE ............................................................................................................2 PREPARING TO USE THE SCALE .............................................................................................2 CHAPTER 1 FEATURES AND SPACIFICATIONS ......................................................................3 1. Features ............................................................................................................................3 2. Options..............................................................................................................................3 3. Specifications ....................................................................................................................3 4. Power Supply ....................................................................................................................4 CHAPTER 2 DISPLAY .................................................................................................................5 CHAPTER 3 KEYBOARD FUNCTION ........................................................................................6 CHAPTER 4 BASIC FUNCTION OPERATION ...........................................................................7 1. Switch On..........................................................................................................................7 2. Re-Zero .............................................................................................................................7 3. Unit Selection ....................................................................................................................7 4. Tare Function.....................................................................................................................8 5. Net/Gross Weight Conversion ...........................................................................................8 6. Simple Counting ................................................................................................................9 CHAPTER 5 ADVANCED FUNCTIONS SETTING ....................................................................10 1. Function Setting 1-1 Auto Backlight Setting 1-2 Auto-off Timer Setting 1-3 Check-Weighing Setting 1-4 Restore to Factory Setting 1-5 Environment Parameter Setting 1-6 Hold Function Setting 2. External Weight Calibration ...............................................................................11 .............................................................12 .............................................................13 .........................................................14 ......................................................15 ..............................................16 ..............................................................17 ...................................................................18
SME300000041
SME300000041
2. Options
2 Second display (customer side) 2 DC 6V/1.2 AH Rechargeable battery 2 Stainless steel platter (220 x 190 mm)
3. Specifications
Model 9903-3 9903-6 9903-15 9903-30 Capacity 3 kg (6 lb ) 6 kg (12 lb) 15 kg (30 lb) 30 kg (60 lb) Division 1 g (0.002 lb) 2 g (0.005 lb) 5 g (0.01 lb) 10 g (0.02 lb)
Operating Temperature: 0C ~ 40C (32F ~ 104F) Power Source: AC 110V/230V (10%) or 4 x UM-1 1.5V dry batteries (not included) Dimensions: 242 x 130 x 285 mm ( W x H x D ) Platter Size: 218 x 188 mm (Plastic platter); 220 x 190 mm (Steel platter) Display: LCD, 6 Digits. 25 mm (Height), LED backlight
SME300000041
4. Power Supply
Power Source: AC 110V/230V (10%) adaptor; 4 x UM-1 1.5V dry batteries; or 6V / 1.2Ah rechargeable battery Power Consumption: With backlight: about DC 14 mA; battery life about 85 hours Without backlight: about DC 24 mA; battery life about 50 hours Low Battery Indication: When the symbol flashes, the battery needs to be
4 The scale will power off automatically after 1 to 2 hours if the battery is not charged.
Please fully recharge the battery before using the scale again.
SME300000041
CHAPTER 2 DISPLAY
HI : When this indicator is on, the weight value is larger than the preset high limit. OK : When this indicator is on, the weight value is between the low and high limits. LO : When this indicator is on, the weight value is less than the preset low limit. kg : lb : Pcs : Indicating that the current weighing unit is kg. Indicating that the current weighing unit is lb. Indicating that the scale is in the simple counting mode.
0 : ZERO indicator and platform stable confirmation. Net: When this indicator is on, the scale is in the tare mode, and the net weight is displayed. : Low Battery indicator
61 : (STABLE) stable indicator 62 : (GROSS) When this indicator is on, the scale is in the tare mode, and the gross weight is displayed. 63 : ( ) In the counting mode, when this indicator is on, the unit weight of the sample is too small. 64 : ( ) In the counting mode, when this indicator is on, the total weight of the sample is too small. 65 : (Hold) Hold weight indicator 66 : GNdwtct unit indicator 67 : oz unit indicator
SME300000041
2.
ON ZERO
: When the scale is off, pressed to switch it on. When the scale is on, if the weight is within the zero range, this key is pressed to re-zero the display or cancel the tare mode. 4 Zero range: OIML & NTEP: 2% of full scale; Sri Lanka: 4% of full scale
3.
TARE
4.
UNITS
5.
NET GROSS
SME300000041
2. Re-Zero
When there is no load on the platter, if the displayed weight is not zero and is within the zero range, press the 4 Zero range: OIML & NTEP: 2% of full scale; Sri Lanka: 4% of full scale
ON ZERO
3. Unit Selection
Press the UNITS key to choose the weight unit kg, lb or the counting unit Pcs. The
unit indicator kg, lb or Pcs will be on. 4 When the scale is switched off, it will memorize the active unit in use, and when it is switched on again, the previous active unit will be shown on the display.
SME300000041
4. Tare Function
(1) Put the container on the platter. When the weight displayed is stable, press the TARE on. (2) Put the object to be weighed into the container, and the display shows the net weight of the object. (3) Remove the container and the object together from the platter. The display will show the negative value of the container weight. (4) Press the TARE key again, the negative value is cleared and the display returns to key. The weight of the container is thus deducted, and the Net indicator is
zero. The Net indicator is off. 4 Tare continuously: When the container weight increases or decreases continuously, it can all be deducted by pressing the 4 TARE key.
key once.
The display will show the gross weight, the Net indicator is off, and the Gross indicator 6
key again, the display will show the net weight, the Net indicator is
on, and the Gross indicator 6 is off. Thus by pressing the key, the net weight and the gross weight can be displayed alternately.
NET GROSS
4 4
The
key is functional.
SME300000041
6. Simple Counting
6-1 Counting mode access
Press the UNITS key to select the Pcs unit, and the scale enters the simple
counting mode.
6-2 Sampling
This important procedure is to let the scale calculate the unit weight: (1) Press the
NET GROSS
(2) Put enough samples onto the platter according to the selected number, and then press the UNITS key. The display shows - - - - - - first. When the scale
becomes stable, the display shows the number of samples on the platter. (3) Remove the samples from the platter, and the scale is ready to count.
6-3 Counting
Place the objects to be counted onto the platter, and the quantity shows on the display.
When any of the following indicator is on, the scale can still count, but inaccuracy may occur: Sample too small ( Unit weight too small ( ): total sample weight is less than 20 divisions ): unit weight is less than 1/5 division.
4 4
The scale will memorize the last sample size when switched off, and the same can be used when the scale enters the counting mode next time. If the number of samples changes by 5 pieces from the last sample used, the scale will calculate the new unit weight automatically.
SME300000041
display shows
10
SME300000041
1. Function Setting
4
Six functions ~ can be set here.
Input 00 ~ 06
If input 00, press the TARE key to return to the upper level category.
Downward digit selecting (9-0) Move the cursor rightward Move the cursor leftward
NET/GROSS
Return to the upper level category Auto backlight setting Auto-off timer setting Check-weighing setting Restore to the factory setting Environment parameter setting Hold function setting
11
SME300000041
UNITS
Auto backlight setting on Turn on the auto backlight off Turn off the auto backlight
Auto backlight mode 1. When there is weight on the platter (the value is larger than 10 divisions), or when any key is pressed, the backlight is on. 2. After the weight on the platter keeps under 10 divisions while no key is pressed, the backlight will be off in about 10 seconds.
12
SME300000041
Auto-off timer setting 0 Auto-off not functional 1 If the scale is not operated for 1 minute, it will automatically switch off. 2 If the scale is not operated for 2 minutes, it will automatically switch off. 9 If the scale is not operated for 9 minutes, it will automatically switch off.
Downward digit selecting (9-0) Move the cursor rightward Move the cursor leftward
NET/GROSS
Auto-off timer If the weight on the platter keeps under 10 divisions while no key is pressed, the scale will automatically switch off after waiting for the set time.
13
SME300000041
.
Input the desired high limit value
kg
.
Press the TARE key
kg
.
Input the desired low limit value
kg
.
Press the TARE key
The display shows the current setting of buzzer parameters Buzzer parameter setting
(a) 1 the buzzer beeps to alarm 0 the buzzer does not beep (b) 1 beep stable 0 beep unstable (c) 1 beeps when the weight is between high and low limit. 0 beeps when the weight is out of high and low limit. (Weight over 10d)
Downward digit selecting (9-0) Move the cursor rightward Move the cursor leftward SME300000041
The restored factory settings include the following: (1) External weight calibration (2) Check-weighing setting (3) Environment parameter setting (4) Sampling value in counting mode
15
SME300000041
Return-to-zero-point setting Default setting = 0 0 No skip 5 skip 5d 1 skip 1d 6 skip 6d 2 skip 2d 7 skip 7d 3 skip 3d 8 skip 8d 4 skip 4d 9 skip 9d 4 The function is active when the weight is over 1/3 of full scale
Digital switch & stabilization range setting
Press the
TARE key
Parameters 0 ~ 9 selectable; Default setting = 0 The larger the number, the easier for the scale to get stable.
Press the
TARE key
Noise filter parameter setting The display shows the current setting Noise filter parameter setting Parameters 0 ~ 9 selectable; Default setting = 5 The larger the number, the speeder the filter reacts. Therefore, larger parameter is suitable for unstable environment.
Press the
TARE key
Downward digit selecting (9-0) Move the cursor rightward Move the cursor leftward
NET/GROSS
4
Dolphin 9903 V 1.1
Hold function setting Default setting = 0 0 No hold function 1 peak hold function mode 2 stable hold function mode 1 3 stable hold function mode 2
Input 00
Downward digit selecting (9-0) Move the cursor rightward Move the cursor leftward
NET/GROSS
No Hold function Peak hold function mode When the weight keeps changing, the scale will automatically hold and display the largest value. Press any key to clear the held value. Stable hold function mode 1 When the scale becomes stable, the display shows and holds the weight value, which can not be changed. Press any key to clear the held value. Stable hold function 2 When the scale becomes stable, the display shows and holds the weight value, which can not be changed. When the scale is re-zeroed (weight less than 10d), the held value is automatically cleared.
17
SME300000041
Press the
TARE key
kg
The display shows the calibration weight (equals to the full capacity) and the weight unit. The last digit flashes. 4 The calibration weight can be modified if necessary.
.
Put the platter on and make sure there is no weight on the platter. Then press the TARE key.
kg
.
Place enough weight to the platter according to the display. When the scale becomes stable, the buzzer beeps for 3 times. Remove all the weights, and the calibration procedure is completed.
Downward digit selecting (9-0) Move the cursor rightward Move the cursor leftward
NET/GROSS
4 4
It is recommended that the external weight calibration should be carried out by a qualified technician from your supplier to ensure the accuracy of the scale.
18
SME300000041
19
SME300000041