NTE962 Integrated Circuit 3Terminal Positive Voltage Regulator, 6V

The NTE962 fixedvoltage regulator is a monolithic integrated circuit in a TO220 type package designed for use in a wide variety of applications including local, oncard regulation. This regulator employs internal current limiting, thermal shutdown, and safearea compensation. With adequate heatsinking it can deliver output currents in excess of 1.0 ampere. Although designed primarily as a fixed voltage regulator, this device can be used with external components to obtain adjustable voltages and currents. Features: D Output Current in Excess of 1.0 Ampere D No External Components Reguired D Internal Thermal Overload Protection D Internal ShortCircuit Current Limiting D Output Transistor SafeArea Compensation Absolute Maximum Ratings: (TA = +25C unless otherwise specified) Input Voltage, Vin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Vdc Power Dissipation (TA = +25C), PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited Derate above +25C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.4mW/C Power Dissipation (TC = +25C), PD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited Derate above +75C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200mW/C Thermal Resistance, JunctiontoAmbient, RthJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65C/W Thermal Resistance, JunctiontoCase, RthJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5C/W Operating Junction Temperature Range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 to +150C Storage Junction Temperature Range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 to +150C Electrical Characteristics: (Vin = 11V, IO = 500mA, TJ = 0 to +125C unless otherwise specified)
Parameter Output Voltage Symbol VO Regline Regload TJ = +25C 5mA IO 1A, PO 15W, 8V Vin 21V Line Regulation TJ = +25C, Note 1 TJ = +25C, Note 1 8V Vin 25V 9V Vin 13V Load Regulation 5mA IO 1.5A 250mA IO 750mA Test Conditions Min 5.75 5.7 Typ 6.0 6.0 9 3 43 16 Max 6.25 6.3 120 60 120 60 Unit V V mV mV mV mV

Note 1. Load and line regulation are specified at constant junction temperature. Changes in VO due to heating effects must be taken into account separately. Pulse testing with low duty cycle is used.

Electrical Characteristics (Contd): (Vin = 11V, IO = 500mA, TJ = 0 to +125C unless otherwise specified)
Parameter Quiescent Current Quiescent Current Change Symbol IB IB RR Vin VO Vn rO Isc Imax TCVO TJ = +25C 8V Vin 25V 5mA IO 1A Ripple Rejection Dropout Voltage Output Noise Voltage Output Resistance ShortCircuit Current Limit Peak Output Current Average Temperature Coefficient of Output Voltage 9V Vin 19V, f = 120Hz TJ = +25C, IO = 1A TA = +25C, 10Hz f 100kHz f = 1kHz TA = +25C, Vin = 35V TJ = +25C Test Conditions Min Typ 4.3 65 2 10 17 0.2 2.2 0.8 Max 8.0 1.3 0.5 Unit mA mA mA dB V V/VO m A A mV/C

.420 (10.67) Max .110 (2.79) GND .147 (3.75) Dia Max .500 (12.7) Max

.250 (6.35) Max .500 (12.7) Min .070 (1.78) Max VIN .100 (2.54) VOUT GND