VF-C
compact
The VF-C inverter has an integrated mains filter as well as 2 user interfaces : AIF: Communications interface FIF: Standard interface Communication modules in the AIF : operator module RS232 / RS485 PROFIBUS System unit Standard I/O module in the FIF : integrated digital/analog I/O PROFIBUS as an alternative
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
VF-C
Improved vector control increases efficiency
Due to vector control, the VF-C inverter achieves considerably higher torque in comparison to conventional V/f control (maximum torque = 1.8 x MN for 60s) and has low level open-circuit power consumption. This function is particularly useful for drives with strong fluctuating loads or high starting inertia, as well as for sensorless speed control of motors requiring slip compensation.
compact
Overview of types:
Performance 1-phase 230 V AC: 0.25 kW 0.37 kW 0.75 kW 1.5 kW 2.2 kW 3-phase 400 V AC: 0.75 kW 1.5 kW 2.2 kW 4.0 kW BFVCE0022A BFVCE0032A BFVCE0072A BFVCE0152A BFVCE0222A BFVCE0074A BFVCE0154A BFVCE0224A BFVCE0404A 1 180 264 V AC 1 180 264 V AC 1 180 264 V AC 1 180 264 V AC 1 180 264 V AC 3 320 550 V AC 3 320 550 V AC 3 320 550 V AC 3 320 550 V AC
(1 115 VAC : 0.12 kW / 0,16 HP) (1 115 VAC : 0.18 kW / 0,24 HP) (3 200 VAC : 0.75 kW / 1 HP) (3 200 VAC : 1.5 kW / 2 HP) (3 200 VAC : 2.2 kW / 3 HP)
Order no.
Dimensions (h x w x d) in mm 120 x 60 x 140 120 x 60 x 140 180 x 60 x 140 240 x 60 x 140 240 x 60 x 140 180 x 60 x 140 240 x 60 x 140 240 x 60 x 140 240 x 100 x 140
Accessories / Interfaces
Type Operator module Remote-control set with operator module 2m cable for remote-control set 5m cable for remote-control set Standard I/O module RS232C / RS485 communication module Cable RS232C to PC-AT Cable RS232C to PLC PROFIBUS AIF module PROFIBUS FIF module Braking resistors Description for entering the parameters; with copy function for flexible manual operation with cable connection Order no.: BFVC 904C BFVC 9060 BFVC 9062 BFVC 9065 BFVC 90XY BFVC 9503 BFVC 9503 PCAT BFVC 9503 PLC BFVC 9901 BFVC 9902 BFVC 9161U BFVC 9162U BFVC 9164U BFVC 9165U BFVC 9166U BFVC 9999 BFVS 29902VC
digital and analog inputs/outputs (already integrated) RS232C and RS485 (multi-drop) for connection to computer or PLC Connection cable between VF-C RS232C port and computer RS232C port Connection cable between VF-C RS232C port and PLC RS232C port, SUB-D 9pin PROFIBUS interface for connection on AIF PROFIBUS interface for connection on FIF for 1-phase 0.25 kW 1.5 kW inverter for 1-phase 2.2 kW inverter for 3-phase 0.75 kW 1.5 kW inverter for 3-phase 2.2 kW inverter for 3-phase 4.0 kW inverter for side mounting of 1.5 and 2.2 kW inverter Inverter configurator software for the inverters VF-8E/X and VF-CE
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
VF-C
compact
One relay output (changeover contact) is integrated in to the system unit as standard (AC 240V/3A, DC 24V/2A 200V/0.18 A)
The standard I/O module (order number.: BFVC 90XY)is included in the VF-C inverter. It need not to be ordered separately.
2. The RS232C / RS485 communication module : Two serial interfaces are available and permit both communications for the application as well as setting and changing the VF-C parameters. RS232C interface : - information message format: 7 bits ASCII, 1 stop bit, 1 start bit, 1 parity bit (even) - bit rate: 1.2 / 2.4 / 4.8 / 9.6 / 19.2 kBaud - access to all parameters - DC supply: internal (5 V) - electric isolation from control/power section RS485 interface : - information message format: 7 bits ASCII, 1 stop bit, 1 start bit, 1 parity bit (even) - bit rate: 1.2 / 2.4 / 4.8 / 9.6 / 19.2 kBaud - max. distance between 2 stations: 1200 m - number of stations: max. 90 (with repeater) - DC supply: internal
3. The PROFIBUS modules : Two different PROFIBUS modules permit open communication in accordance with the international EN 50170 standard. The PROFIBUS FIF module is used instead of the standard I/O module. If the standard I/O module is necessary in the application, the PROFIBUS AIF module can be used as the automation interface. - bit rate: 9.6 kBaud ... 12 MBaud (automatic detection) - max. cable length: 1.2 km (depend on baudrate and cable) - number of stations: 32 (with repeater 125) - PROFIBUS status: Slave - communication profile: PROFIBUS-DP (DIN 19245, parts 1 and 3) - drive profile: DRIVECOM Profile 20 - access to all parameters CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
VF-C
The VF-C inverter operator module :
compact
The operator module allows entry or changes to the VF-C parameters as well as the display of the current drive parameters. The VF-C parameters can be saved in to the operator module and simply copied into another VF-C inverter. Time-consuming parameter setting for larger applications is therefore no longer required and errors are reduced accordingly. The VF-C inverter operator module can be directly plugged in to the VF-CE AIF interface or operated as a remote-control set with a 2m or 5m cable. The remote-control set can also be installed in switch-gear cabinets and operator consoles. The operator module is not included with the VF-C inverter and is available as an option.
Clear or block motor Jumping within function and Jumping within function Selecting codes and changing the parameters Adopting changed parameters
1 --2
ENTER
2. Assembly kit for control cabinet walls After removing the rubber protective holder of the remote-control set, the keypad can be mounted in switch-gear cabinets and operator consoles. (cut-out 45.3 x 45.3mm).
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
VF-C
compact
Technical data
Control method Operating frequency Maximum torque Torque speed range Sensorless speed control V/f control (linear, square), vector control Either 2 kHz, 4 kHz, 8 kHz, 16 kHz 1.8 x MN for 60 s, if motor rated power = inverter rated power 1 : 10 (3 50 Hz, constant speed) Min. output frequency 1.0 Hz ( 0 MN) sensorless speed control Speed range 1 : 50 ( based on 50 Hz) Accuracy 0.5 % 3 50 Hz Smooth running 0.1 Hz 3 50 Hz Integrated braking transistor Integrated as standard-class B Up to 3 skip frequencies can be set to avoid resonance Motor parameter adaptation and correction, thermo-couple input for monitoring motor temperature, 1 ms terminal sampling time, linear and S-ramp, fixed speeds, four parameter programs can be switched online, bipolar set-point processing.
Generator operation (monitored internally) Filter Skip frequencies Other standard features
VF-C
Technical data
Type System voltage Alternative DC supply to + UG -UG Umains [V] UDC [V] 1PE AC 3.4 0.25 0.34 0.68 BFVCE0022A BFVCE0032A
5)
compact
BFVCE0072A
BFVCE0152A
BFVCE0222A
not possible
5)
Data for operation at 1 (3) PE AC 240 V Mains rated current Motor power (4-pol. ASM) Output power U, V, W Output power +UG -UG Output rated current
2)
1PE AC 3 PE AC 1 PE AC 3 PE AC 1 PE AC3) 3 PE AC 9.0 0.75 1.0 1.6 0 4.0 4.0 2.6 6.0 6.0 3.9 5.2 15.0 1.5 2.0 2.8 0.7 7.0 7.0 4.6 10.5 10.5 6.9 9.1 18.0 2.2 3.0 3.8 0 9.5 9.5 6.2 14.2 14.2 9.3 12.4
Imains [A] PN [kW] PN [hp] SN8 [kVA] PDC [kW] IN24 [A] IN8 [A] IN16 [A] Imax24 [A] Imax8 [A] Imax16 [A] UM [V] PV [W] m [kg]
DC interconnection not possible 1.7 1.7 1.1 2.5 2.5 1.7 2.4 2.4 1.6 3.6 3.6 2.3
2/4 kHz* Max. permissible output current 8 kHz* for 60s1) 16 kHz* Motor voltage Power loss (operation with IN8) Weight
0 3 x Umains/0 Hz 50 Hz, up to 480 Hz 30 0.65 40 0.65 60 0.95 100 1.4 130 1.4
Type System voltage Alternative DC supply to + UG -UG Data for operation at 3 PE AC Mains rated current Motor power (4-pol. ASM) Output power U, V, W Output power +UG -U Output rated current
2) G
BFVCE0074A
BFVCE0154A
BFVCE0224A
BFVCE0404A
Umains [V] UDC [V] 400 V Imains [A] PN [kW] PN [hp] SN8 [kVA] PDC [kW] IN24 [A] IN8 [A] IN16 [A] Imax24 [A] Imax8 [A] Imax16 [A] UM [V] PV [W] m [kg] 2.4 2.4 1.6 3.6 3.6 2.4 3.3
3 PE AC 320 V 0% 550 V + 0%; 48 Hz 0% 62 Hz + 0% DC 450 V 0% 770 V + 0% 500 V 2.6 0.75 1.0 1.7 0 1.9 1.9 1.4
4)
400 V 5.5 1.5 2.0 2.7 1,5 3.9 3.9 2.5 5.9 5.9 3.9
500 V 4.4
500 V 5.8
500 V 9.8
2/4 kHz* Max. permissible output current 8 kHz* 1) for 60s 16 kHz* Motor voltage Power loss (operation with IN8) Weight
0 3 x Umains/0 Hz 50 Hz, up to 480 Hz 60 0.95 100 1.4 130 1.4 180 2.3
Bold type = data for operation with 8 kHz switching rate (pre-set in factory) 1) Current for periodic load alternation with 1 minute of excess current with I max and 2 minutes of base load with 75 % INx 2) For operation with performance-adapted motor in addition to the performance drawn from the intermediate circuit 3) Operation only permitted with a.c. reactor/mains filter 4) Max. permissible motor rating length: 10m shielded * Power inverter switching rate 5) For 1-phase 115 VAC use at BFVCE0022A and BFVCE0032A there is a derating of max. 0.75 x I N. The parameter CO22 has to be set to 75%.
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
VF-C
compact
Functionality: - parameter entry - test operation (Start/Stop, Forward/Reverse, Acceleration/Deceleration, etc.) - drive monitoring - saving and documenting the settings
To operate Motion Control, requirements: - a personal computer with min. 486DX4 100MHz processor and 8MB RAM (better Pentium 133MHz, 16MB RAM) - a video card with 640x480 resolution (better 800x600) - MS Windows 95 / 98 / MS Windows NT - a Matsushita inverter
Drive Selection
After clicking on Let me select the inverter or Open a new project from the Quick Launch window, an inverter selection window opens which lists all Matsushita VF-8E, VF-8X and VF-CE drives. Selecting a drive automatically opens the Project Navigator window and loads the default parameter settings for the selected drive.
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
VF-C
Project Navigator
Project Navigator is the active project managment window. By double-clicking on the tree branches, it is possible to: - have access to the communication settings in order to establish communication with the drive(s) - have access to edit the parameters (parameters are grouped by common theme) - make ones own parameter groups with the PUG Wizard (Parameter User Groups) based on application / user needs.
compact
Editing Parameters
The Parameter Edit windows display common groups of parameters with the default values that pertain to the selected drive. From these windows it is possible to: - edit the drive(s) parameters - upload into one or more drives or download a set of parameters from a drive. - start a comparison between the current project and the drive, or between two drives regarding the currently selected parameters
Status Monitor
The Status Monitor displays the current drive status, command status, and fault conditions of a drive that is on-line and communicating with the configuration software. Different windows can be selected. Status Monitor: - Monitors the on/off status of the following parameters: Run (inhibited), Forward, Reverse (CCW rotation), Frequency Arrival, Overload Alarm, and others - Monitors the current values of Output Frequency, Frequency Setting, Output Current, and Output Voltage (Measured values) The Status Monitor can be opened by an icon
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
VF-C
compact
Fault Screen
The Fault Screen displays the current drive status and a fault history of the last three alarm conditions as read from the drive, with the first fault being the most recent.
Trend Window
The real-time trend graphs provide constantly updated and easy to interpret snapshots of drive operation. They immediately show the relationship between output frequency, voltage, and current, which can be very helpful in confirming proper operation and in troubleshooting performance problems. Further parameters and values are selectable. The Trend Window can be opened by an icon on the toolbar.
Command Panel
The Command Panel allows direct control of the drive from the configuration software. From here it is possible to: - start and stop the drive - change motor direction from forward to reverse - control the drives frequency setting by drag-rotation of the speed dial with the mouse pointer or by directly entering a value in the frequency display field - set/reset important parameters. The Command Window can be opened by an icon on the toolbar.